Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
ROCKHILL BLK 2 LT 28
Onsite File Rockhill Block 2 Lot 28 #015-063-25 PIPE MATERIAL House to tank Tank to Installer F1488 drainfield D3034 RED DOG MASONRY Drainfield D3034 CO/MTD3034 Inspector GEG AND MOA BENCH MARK (Assumed elevation) -- Inspection dates: 1n 2/4/2022 2nd 2/24/22 Location and description ,h TOP OF MHIT s 2/28/22 4 ON-SITE WATER AND WASTEWATER SECTION APPROVAL Engineer's Stamp ©0600 Conditional Approval: Date o * . 4 T �p...... .... .. ....... ..........� .::.. ......... �...� Septic System y A. orn ss:' Q Approved Date l©02� ��0�-. CE 79 3 v pO Q e ' ;`a.3 Note: this approval does not include well permit requirements. 4�p�f'rofession°10 #AECC884 ��00000" (Rev 05/02/18) UVe'<Go-45 0'J �f(g/ Z_7 Q4 Municipality of Anchorage On -Site Water and Wastewater Section • (907) 343-7904 Page 1 of 3 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP211170 PID Number: 015-063-25 Dwelling: ❑ Single Family (SF) ❑ with ADU ❑ D Duplex p (D) F] Two Single Family Project: RN New ❑Upgrade Name ALEXANDRA NENAHLO ABSORPTION FIELD ❑ Deep Trench ❑ Wide Trench ❑ Bed ❑ Mound ❑ Other Soil Rating Total depth from original grade 1.2 GPD/SF 6.75 (MAX) Ft. Depth to pipe invert from original grade Gravel depth beneath pipe SEE DWG. Ft. 4 & 4 Ft. Fill added above original grade Gravel length SEE DWG. Ft. 32 & 33.5 Ft. Site Address 9811 MAIN TREE DRIVE *ANCHORAGE, AK Phone Number of Bedrooms 5 LEGAL DESCRIPTION Subdivision Block Lot ROCKHILL; BLOCK 2, LOT 28 Township Range Section N/A Gravel width��� 5 & 5 Ft. Total bsarl5fion-a- t,-}. 0 -$. Ftx Beds: Number of Lines - Number of trenches 2 Distance between lines - Ft. Dist. between trenches 8'+ Ft, SEPARATION DISTANCES To Septic Absorption Holding Sewer Lift Station From Tank Field Tank Line Well *100'+ *100'+ _ _ 25'+ TAN epti ❑ S.T.E.P. ❑ Holding ❑ Other Manufactur b) � Bz GREER TANK Capacity 1500 Gal. Surface Water 100'+ 1001+ _ _ Material Number of compartments Lot Line 10'+ 10'+ - - NA PLASTIC 2 Foundation 10'+ 10'+ _ _ LIFT STATION Manufacturer Capacity Remarks *WELL SEPERATION DISTANCE TO ADJACENT Gal. SEPTICS CONFIRMED BY KEN LANG, PLS PRIOR TO DRILLING WELL Alarm location Electrical installed by PIPE MATERIAL House to tank Tank to Installer F1488 drainfield D3034 RED DOG MASONRY Drainfield D3034 CO/MTD3034 Inspector GEG AND MOA BENCH MARK (Assumed elevation) -- Inspection dates: 1n 2/4/2022 2nd 2/24/22 Location and description ,h TOP OF MHIT s 2/28/22 4 ON-SITE WATER AND WASTEWATER SECTION APPROVAL Engineer's Stamp ©0600 Conditional Approval: Date o * . 4 T �p...... .... .. ....... ..........� .::.. ......... �...� Septic System y A. orn ss:' Q Approved Date l©02� ��0�-. CE 79 3 v pO Q e ' ;`a.3 Note: this approval does not include well permit requirements. 4�p�f'rofession°10 #AECC884 ��00000" (Rev 05/02/18) UVe'<Go-45 0'J �f(g/ Z_7 Q4 PERMIT NUMBER: RECORD DRAWING PARCEL ID NUMBER: OSP211170 015-063-25 ANEW DRAINFIELD F0 ' 0 0 , t \ r NEW5BEDROOM d HOUSE v d v v . 4 v a• •. DRIVEWAY 4.4 a a. 4 d v 4 a 4 • MARYLAND; LOT 6-A 1N r. ENGINEERING SALES CONSULTING {.. � �. g war. MH1 52.5 68.0 PREPARED FOR: PHONE NUMBER: T2 CO3 ALEXANDRA NENAHLO 2 OF 3 ST1 56.9 72.8 \ ROCKHILL; BLOCK 2, LOT 28 D.J.G. TYPE OF WORK: DATE: �, SEPTIC SYSTEM RECORD DRAWING 5/31/2022 MT3 -- DBL1 58.9 75.2 DBL2 60.9 77.3 FS 112.8 128.9 MT FS C01 108.1 121.4 MT1 110.3 123.8 I CO 2 137.4 153.5 C 4 MARYLAND; • LOT 5-A � MT MT2 134.9 151.3 O CO3 132.3 151.2 _ MT3 128.8 148.0 W C04 101.4 116.5 3 MT4 104.2 121.2 o SWING TIES WERE GENERATED IN AUTOCAD FROM AS -BUILT SURVEY BY / 0 KEN LANG, PLS (ATTACHED) ST1 DBL182 0 O MH1 0 f - U O QNEW 1500 GALLON HDPE GREER TANK LU w / c2 SEE ATTACHED SURVEY BY KEN LANG ,PLS WHICH SHOWS THE CLOSEST CLOS] SEPTIC PIPES FOR LOT 5-A AND LOT F0 ' 0 0 , t \ r NEW5BEDROOM d HOUSE v d v v . 4 v a• •. DRIVEWAY 4.4 a a. 4 d v 4 a 4 • MARYLAND; LOT 6-A N SCALE: 1" = 40' OF Y, �....... .4 .z .............. r .. .............. ....... : .... r L� J ffde Garnes .cam ♦�f C 7 '=s LICENSE�41 •ES/S• : #AECC884 1N r. ENGINEERING SALES CONSULTING {.. � �. g war. 3701 E. TUDOR ROAD. SUITE 101 'ANCHORAGE, AK 99507' PHONE (907) 3378179' FAX (907) 33&3246' WEBSITE: w.xv.9ames gmeenng.com PREPARED FOR: PHONE NUMBER: PAGE NUMBER: ALEXANDRA NENAHLO 2 OF 3 LEGAL DESCRIPTION: DRAWN BY: ROCKHILL; BLOCK 2, LOT 28 D.J.G. TYPE OF WORK: DATE: �, SEPTIC SYSTEM RECORD DRAWING 5/31/2022 N SCALE: 1" = 40' OF Y, �....... .4 .z .............. r .. .............. ....... : .... r L� J ffde Garnes .cam ♦�f C 7 '=s LICENSE�41 •ES/S• : #AECC884 PERMIT NUMBER:RECO RECORD DRAWING A WI N A PARCEL ID NUMBER: OSP211170 ,1.�`+H (V- 015-063-25 TOP OF TANK AT INTLET = 97.05 INVERT OF BUNG AT INLET = 2019 T.H. BY MICHAEL E. ANDERSON,PE WEST TOP OF MH = 103.05 FINAL GRADE = 101.6-102.9 MH NEW 1500 GALLON H.D.P.E. GREER SEPTIC TANK RATED FOR 10' BURIAL GRADE = 95.0-94.9 -ORIGINAL GRADE AT HIGHEST POINT = 94.09 FILTER FABRIC FINAL GRADE = 95.4-96.0 'LIGHTLY SHY ON COVEF TOP OF TANK AT OUTLET = 97.03 INVERT OF BUNG AT OUTLET = 96.18 EAST -ORIGINAL GRADE AT HIGHEST POINT = 94.93 2019 T.H. BY MICHAEL E. ANDERSON,PE TER FABRIC RELATIVE ELEVATION OF BOTTOM OF T.H. = 81.09 T.H. DRY ON 2/24/22 - rrQF ENGINEERING- SALES -00NSULTING r ? 3701 E. TUDOR ROAD, SUITE 101 -ANCHORAGE, AK 99507. PHONE (907) 337-6179 -FAX (907) 3383246 • WEBSITE vxna.game gineenng.com PREPARED FOR: PHONE NUMBER: PAGE NUMBER: ALEXANDRA NENAHLO 30173 LEGAL DESCRIPTION: DRAWN BY: ROCKHILL; BLOCK 2, LOT 28 D.J.G. TYPE OF WORK: DATE: SEPTIC TANK PROFILE 5/31/2022 T INVERT OF T4.0' PIPE = 92.18 INVERT OF PIaPE = 91.34 5 -"I BOTTOM OF 5' TRENCH = 88.18 BOTTOM OF TRENCH = 87.34 RELATIVE ELEVATION OF BOTTOM OF T.H. = 81.93 / 81+ T.H. DRY ON 2/24/22 J RELATIVE ELEVATION OF BOTTOM OF T.H. = 81.09 T.H. DRY ON 2/24/22 - rrQF ENGINEERING- SALES -00NSULTING r ? 3701 E. TUDOR ROAD, SUITE 101 -ANCHORAGE, AK 99507. PHONE (907) 337-6179 -FAX (907) 3383246 • WEBSITE vxna.game gineenng.com PREPARED FOR: PHONE NUMBER: PAGE NUMBER: ALEXANDRA NENAHLO 30173 LEGAL DESCRIPTION: DRAWN BY: ROCKHILL; BLOCK 2, LOT 28 D.J.G. TYPE OF WORK: DATE: SEPTIC TANK PROFILE 5/31/2022 0211612022 02:59 907-345-0202 ALPINE DRILLING PAGE 01101 Alpine Drilling' & Enterprises Permit Number: #SW211170 Date of Issue: 6-2-2021 d �' 0 -,?5 Parcel Ideutafication Number: 01503Q Date Started: 9-30-21 irate Completed: 10-1`5-21 Is well located at approved permit location? x Yes ❑ No Legal Description: Rockhill Block 2 Lot 28 Property Owner Name & Address: Thomas & AleNandra Nenahlo - Watermark Construction 9811 Main Tree Dr Anchorage, Alaska Borehole Data: Depth (ft} Soil Type, Thickness & Water Strata From To stickup 0 2 cobbly silty gravel 2 11 gravelly silt Il 60 gravel- sandy silt H2O 4gpm 60 65 gravelly silt 63 __ 84 gravelly scmdy silt 84 93 gravelly silty sand X20 93 100 silt 100 102 WATER CK)ALffy TESTING ConformC01/100ml- Nitrates Areeft a Method of Drilling x air rotary ❑ cable tool Casing type: steel Wall Thiclmess:.250 inches f�AN Diameter: 6 inches Depth; 96 feet Liner Type: Diameter: inches Depth.- feet Casing stickup above ground: 2 feet Static water level (from ground Ieve1}: 68 feet Pumping level: 93 feet after 2 hours pumping 4 gpm Recovery Rate: 4 gpm Method of Testing; um Well Intake Opening Type: ❑ Open End ❑ Open Hole x Screened Start 96 feet Stopped LO -Q feet ❑ Perforations Start feet Stopped feet Grout Type: bentonite granules Volume: I biz II Pump: Intake Depth feet II Pump size hp Brand Name IIWell Disinfected Upon Completion? x Yes ❑ No �� Method of Disinfection: Comments: For reference 62 to 65 casing level, silty water sand & gravel Would have to drill another -well to utilise as static level on used well is 68 feet approximately 4 gpm could increase by screening. Well Driller: Alpine Drilling & Enterprises PO Box 110496 Anchorage AK 99511 MUNICIPALITY OF ANCHORAGE Development Services Department Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Pump Installation Log Well Drilling Permit Number: 211170 Date of Issue: 9 3021 Parcel Identification Number: 015 032 5000 Legal Description Rock Hill Block 2 Lot 28 Property Owner Name & Address: Thomas and Alexandra Nenalo Pump Installation Date: 12 -12 -21 Pump Intake Depth Below Top of Well Casing: 05 feet Pump Manufacturer's Name: Goulds Pump Model:7HS05 Pump Size: 1/2 hp Pitless Adapter Burial Depth: 11 feet Pitless Adapter Manufacturer's Name: Martinson B-1 0 Pitless Adapter Installer: Red Dog Masonary Well Disinfected Upon Completion? 0 Yes 0 No Method of Disinfection: Chlorine tablets Comments: Pump Installer Nam.. David Harper Company: Aarow Pump & Well Service, LLC Mailing Address: PO Box 110496 City: Anchorage State: AK —zip: 99511 Attention: The pump installer shall provide a pump installation log to On-site within 30 days of pump installation. . Municipality of Anchorage Community Development Department On -Site Water & Wastewater Program 47OOElmore St. MP.Q.Box 196G5UnAnchorage, AK995O7-6GSOa 0(907)343-7904 Legal Address: Subdivision T Block R Section Lot On-site Water & Wastewater Program certified contractor performing the well decor Signature Name Company: __j Well decommissioning date Method ofdecommissioning: AK8C15:55lK60L1 a [] b El c e� Location: Use the space below to provide a drawing of the property showing the following items; • North Arrow w Decommissioned well, • Other water wells onthe property, w Two separate swing -tie distances for each well shown inthe drawing, Not ' e: The swing -tie distances shall be measured from either permanent structures of property corners. � / R r m UM 0 w R r m w � t� s¢ x x <g s$ d� MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Water & Wastewater System Permit Permit Number: OSP211170 Work Type: WellSeptic Initial Tax Code Number: 01506325000 Site Legal Address: ROCKHILL BLK 2 LT 28 G:2438 Site Mailing Address: 9811 Main Tree DR, Anchorage Owner: NENAHLO THOMAS & ALEXANDRA Design Engineer: GARNESS ENGINEERING GROUP LTD This permit is for the construction of: P Disposal Field P Septic Tank ❑ Holding Tank ❑ Privy Effective Date Expiration Date: Lot Size in Sq Ft: Total Bedrooms: �1»cnt U. rt � err: I:)eparlrne]It 6/2/2021 6/2/2022 53889 P Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezinq qy"(2 �A - A : io c O� CL_ \ Received By: 'n Issued By: Jf'_t z / I '7 ZZ Date: Date: // 1l1 �2 5 MUNICIPAUTY OF ANCHORAGE SVic:- .'��= Development Services Department Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 ON-SITE SEPTICIWELL PERMIT APPLICATION Parcel I.D. 015-063-25 Property owner(s) ALEXANDREA NENAHLO Mailing address MAIN TREE DRIVE *ANCHORAGE, AK Site address ` 8 Day phone Legal description (Sub'd., Block & Lot) ROCKHILL; BLOCK 2, LOT 28 Legal description (Township, Range & Section) .r Lot Size Sq. Ft. Number of Bedrooms APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (® all that apply) Absorption Field 0 Initial Single Family (SF) El (wlwo ADU) Septic Tank ElUpgrade ElDuplex ❑ (D) Holding Tank ❑ Renewal ❑ Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well Water Storage ❑ THIS APPLICATION INCLUDES A WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: g U Waiver Fees: Date of Payment: SX2 (o 0 Date of Payment: Receipt Number: 0 3 3 2 G Receipt Number: Permit No. 0522 9 % % 7 0 Waiver No. GADevelopment Services\Building Safety\On Site Water and Wastewater\Forms\Client FormsTermit Application.doc Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP211170, Rebecca Carroll, 06/02/21 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP211170, Rebecca Carroll, 06/02/21 DESIGN CRITERIA: NUMBER OF BEDROOMS: 5 GALLONS PER DAY (GPD): 750 PERCOLATION RATE/S: <1 MIN/INCH PROPOSED APPLICATION RATE: 1.2 MINIMUM DRAINFIELD SQ.FT.: 625 FT' DRAINFIELD DESIGN: MAXIMUM DEPTH: 6.75 FEET WIDTH: 5.0 FEET LENGTH: 64 FEET (32 AND 32 FEET) M.O.A. APPROVED SAND FILTER: N/A. SEE ATTACHED LETTER EFFECTIVE: 4 FEET REDUCTION FACTOR: 0.5 FEET ACTUAL SQ.FT.: 640 FT, TESTHOLE LOCATIONS AND TOPO INFORMATION ARE TAKEN FROM PLOT PLAN PROVIDED BY KEN LANG, PLS \ IP RESERVE SITE DESIGN CRITERIA: NUMBER OF BEDROOMS: 5 GALLONS PER DAY (GPD): 750 PERCOLATION RATE/S:<i MIN/INCH PROPOSED APPLICATION RATE: •4.0 MINIMUM DRAINFIELD SQ.FT.: 187.5 FT' 'CAT II ADVANCED TREATMENT CJD -41 GEG, Lid. HAS AN 8 PAGE SPECIFICATION LETTER THAT PERTAINS TO THIS DESIGN, BY PROCEEDIN( FORWARD WITH THIS INSTALLATION, THE ENGINEER, WELL DRILLER, CONTRACTOR AND PROPERTY OWNER AGREE THAT THEY HAVE READ THESE SPECIFICATIONS AND AGREE TO ACCEPT THE TERMS AND CONDITIONS OUTLINED. SEPTIC AREA ROCKHILL; BLOCK 2, LOT 27 X25/ RESERVE SITTE DRAINFIELD DESIGN: MAXIMUM DEPTH: 8.5 FEET PAGE NUMBER: WIDTH: 5 FEET �,4 LENGTH: 40 FET EFFECTIVE: 0.5 FEET 2 OF 2 REDUCTION FACTOR: N/A T/Q� ACTUAL SQ.FT.: 200 FT' �� F F PROPOSED HTSSEE G A R NESS ENGI N G GR 0 iJ P , Ltc = -- ENGINEERING- SALES HCONSULTING 3701 EAST TUDOR ROAD SUITE 101 'ANCHORAGE. ALASKA -PHONE (907) 337-6179 - WEBSITE: mm gamessengineenng.com PREPARED FOR: PHONE NUMBER: PAGE NUMBER: ALEXANDRA NENAHLO 2 OF 2 PROJECT/LEGAL DESCRIPTION: DRAWN BY: ROCKHILL; BLOCK 2, LOT 28 D.J.G. TYPE OF WORK: DATE: SEPTIC SYSTEM DESIGN 2/17/2022 CONTRACTOR TO HAVE ALL 100'/ WELL RADAII SHOWN, EAST AND WEST LOT LINES FLAGGED BY A PLS PRIOR TO CONSTRUCTION I MARYLAND; LOT 3-A MARYLAND; LOT 4-A SITE DRAINFIELD MARYLAND; LOT 5-A EW SEPTIC TANK HAS BEEN INSTALLED; TANK WAS MOVED CLOSER TO DRAINFIELD; GEG DOES NOT HAVE A SURVEY TO BE ABLE TO ACCURATELY SHOW THE NEW TANK LOCATION 1 n l^h C O P•••••..... �i C. # Ar Al 9 ..................... �I k • •7�f�frey A_GaCa�SS• Lu. ♦�GT�� E-7 3 • LICENSE �i�FESSi�.•• #AECC684 ���mm* Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP211170, Rebecca Carroll, 06/02/21 SOILS • PERCOLATION LEGAL DESCRIPTION: ROCKHILL 132 L28 PERFORMED FOR: ALEXANDRA NENAHLO DATE: 10/25/19 PROJECT No.: PARCELID#: 015-063-25 TECHNICIAN: J. WILLIAMS DEPTH TH# 1 NORTH (feet) 1 2 3 4 5 6 7 8 9 1 11 12 13 14 15 16 17 18 19 20 COMMENTS: LOU SM/GW SANDY GRAVEL (MOSTLY SAND WITH OCCASIONAL COBBLES) SLOPE WAS GROUNDWATER ENCOUNTERED? NU IF YES @ WHAT DEPTH? - DEPTH TO WATER AFTER MONITORING: NONE DATE OF MONITORING: 11/7/19 DATE READING GROSS TIME (MINUTES) NET TIME (MINUTES) DyEPTET O (INCHES) TH#1 T42 LOT 27 ` '-� LOT 28 1 5:10/5:11 <1 min 0-1% 616 DATE READING GROSS TIME (MINUTES) NET TIME (MINUTES) DyEPTET O (INCHES) NET DROP (INCHES) 11/7/19 TEST HOLE PRESOAKED PRIOR TO TESTING: 1 5:10/5:11 <1 min 0-1% 616 2 5:12/5:13 <1 min 0-11 6-6 3 5:14/5:15 <1 min 00/6 0 60 4 5:15 / 5:15 <1 min 0 16 / 6 % 60 5 5:17/5:17 <1 min 00/6 0 6�0 6 5:18/5:18 <1 min 0-1/60 6.1 PERCOLATION RATE: <1 (MIN/INCH) PERC. HOLE DIA. 6 {INCHES) TEST RUN BETWEEN: 3 FT. and 4 FT. Y � C A y[i4m' NORTHERN GEOTECHWAL ENGINEERJNG, INC..// TERRA FIRMA TESTING PROJECT CLIENT: Forge Engineering PROJECT NAME: RociChill PROJECT NO.: 5248-19 SAMPLE LOC.: Block 2/ Lot 28 NUMBER/ DEPTH: ASTM D1557 (uncorrected) DESCRIPTION: Poorly -graded sand w/ gravel DATE RECEIVED: 11/25/2019 TESTED BY: JA REVIEWED BY: RJPC 100 90 80 70 EI) 60 6 50 40 30 w 20 10 0 145 140 U 135 E-' Z 130 w Q >' 125 q % GRAVEL 34.1 % SAND 62.7 % SILT/CLAY 3.2 % MOIST. CONTENT 7.5 USCS USACOE FC % PASS. 0.02 mm % PASS. 0.002 mm SP N/A N/A N/A UNIFORMITY COEFFICIENT (C„) 19.7 COEFFICIENT OF GRADATION (Ce) 0.6 ASTM D1557 (uncorrected) N/A ASTM D4718 (corrected) N/A 100 OPTIMUM MOIST. CONTENT. (corrected) N/A 3/4" PARTICLE SIZE ANALYSIS ASTM D422 / C 136 US. SIEVE OPENING M INCHES I U.S. SIEVE NUMBERS I HYDROMETER 100 10 1 0.1 0.01 0.001 GRAIN SIZE (mm) GRAVEL SAND COBBLES SILT or CLAY Coarse Fine Coarse Medium Fine MOISTURE -DENSITY RELATIONSHIP ASTM D 1557 120 ; , ' _ 115 ' 0 2 4 6 8 10 12 14 16 MOISTURE CONTENT (%) SIEVE ANALYSIS RESULT SIEVE SIZE (mm) SIEVE SIZE (U.S.) TOTAL % SPECIFICATION PASSING (% PASSING) N/A (ASTM D2434) 152.40 6" 76.20 3" 38.10 1.5" 100 19.00 3/4" 95 12.70 1/2" 89 9.50 3/8" 83 4.75 #4 66 2.00 #10 49 0.85 #20 35 0.43 #40 24 0.25 #60 14 0.15 #100 7 0.075 #200 3.2 HYDROMETER RESULT ELAPSED DIAMETER TOTAL TIME (MIN) (mm) PASSING 0 0.5 1 2 4 8 15 30 60 250 1440 HYDRAULIC COND. N/A (ASTM D2434) DEGRADATION N/A (ATM T-313) PLASTICITY INDEX N/A ASTM 4318 The testing services reported herein have been performed to recognized industry standards, unless otherwise noted. No other warranty is made. Should engineering interpretation or opinion be required, NGE-TFT will provide upon written request. 11301 Olive Lane Anchorage, Alaska 99515 Phone: 907-344-5934 Fax: 907-344-5993 wtivw.nge-rft.com SOILS••• 4, LEGAL DESCRIPTION: ROCKHILL B2 L28 PERFORMED FOR: ALEXANDRA NENAHLO DATE: 10/25/19 PROJECT No.: PARCELID#: 015-063-25 TECHNICIAN: J. WILLIAMS DEPTH TH#2 SOUTH (feet) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18- 19. COMMENTS: 1,60] SM/GW SANDY GRAVEL (MOSTLY SAND WITH OCCASIONAL COBBLES. GETS SILTIER WITH DEPTH) SLOPE WAS GROUND WATER ENCOUNTERED? N O IF YES @ WHAT DEPTH? - DEPTH TOWATER AFTER MONITORING: NONE DATE OF MONITORING: —71/ 7 / 19 �t TH#1 TH#z LOT k 27 LOT w 28 DATE READING GROSS TIME (MINUTES) NET TIME (MINUTES) DEPTH TO WATER (INCHES) NET DROP (INCHES) 11/7/19 TEST HOLE PRESOAKED PRIOR TO TESTING: 1 4:45 <1 min 0 0/ 6 0 6 -1 2 4:47 <1 min O 6°s / 616 616 3 4:50 <1 min O 6/ 6 16- 6 6 4 4:51 <1 min 0 0 / 616- 616- 5 4:52 <1 min 00 / 6 6 6 6 6 4:55 <1 min 0 s/ 6 s 6 0 PERCOLATION RATE: <1 (MIN/INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN: 3 FT. and 4 FT. GROUP,GARNESS ENGINEERING a. __ ENGINEERING &- SALES 4, CONSULTING q •a— -_ �._.. __ February 161h, 2022 �34 Municipality of Anchorage Development Service Department,?4gTk� •';*' j On -Site Water & Wastewater Program 4700 Elmore Road�. • •� s •;,�I:'• J�ilrey x{ess. /� Anchorage, AK 99507 ��c �Q CE -795353 �� Ref: Rockhill; Block 2, Lot 28 — Change Order for drainfield location . • AM To whom it may concern: The subject lot is vacant and was issued a permit on 6/2/2021. The owner decided that they would like the drainfield to be designed around Testhole #2 instead of Testhole #1. Due to this fact, a sieve analysis was pulled on 2/4/2022 at 4-5 feet below grade and submitted to a lab for analysis. As can be seen on the attached sieve, the soils were classified as a GW. Per the testhole by Forge Engineering the soils get "Siltier with Depth". Based upon this statement, two additional sieves were pulled at 6 feet and 8 feet. Per the attached sieves, the soils get "finer' with depth and were classified as a SP -SM at 8 feet. In short, it is assumed that there is sand from 8-13 feet and a sand filter would not be required. See attached drawings for drainfield design criteria. We are unaware of any adverse impacts this installation would have on adjacent wells or septic systems. If you have any questions, please contact us at 337-6179.. _Thank you for your 3701 East Tudor Road, Suite 101 * Anchorage, Alaska 99507-1259 Phone: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.garnessengineering.com .Material Test • •' • `) Client: Garness Engineering Group Ltd. 3701 East Tudor Rd. Anchorage, AK, 99507 Project: 2022 Testing Sample ID 22-0100-S01 Client Sample ID Rock Hill General Location Blk. 2, Lot 28 TH#2 Alaska Testlab - Anchorage 4040 B Street, Suite 102 Anchorage, AK 99503 Phone: 907-205-1987 Fax: 907-782-4409 info@afaskatesilab.com Project Code: 220453 The results container) below Iter ns only to the Ites tested below. This report should not W reproduced, except In full, without the pdorwritlen approval of Alaska Testtab orthe agency. CC: david Garness Maria Kampsen Reviewed By: Maria E Kampsen Title: Senior Engineer Date: 2/7/2022 Description Method Result Limits Group Code ASTM D2487 GW Group Name Well -graded gravel with sand Atterberg Limits Estimated Yes Tested By Cindy Zickefoose Date Tested 2/7/2022 Method ASTM D6913 A Preparation Method Oven Dry Composite Sieving? Yes Separating Sieve(s) No. 4 Fractional Mass Retained (%) 0.00 Cu ASTM D2487 30.16 Particle Size Distribution Method: ASTM D6913 Diameter Drying By; Oven 100 so 20 s 2 soo 200 100 50 Date Tested: 2/7/2022 mm Pin Tested By: Cindy Zickefoose 100 ._-- ._-- �--�--___ ----...__. __:_.____ 90--_--------------- - ._. ----_ _---- ---------- Sieve Size % Passing Limits 3in 100 80 - . _ _ --- - - _ - - - -._... - -----I- - - - - _--- ---- 2in 90 Thin 90 lin 82 - -69 � E ''/zin 57 0 60 - - -- --- -- - - - _ -- -- - -- - - . ---- .._.. -- - -- - _ 3/8in 50 No.4 34.0 N No.10 25 50 - _-- - --- - - - - -- - - -- -- --- -- _ - No.20 15 �, No.40 9 40-- - _ ------- -- - - -- - ---- -- ---- — ---- ------ �_ No.60 6 No.100 4 ° - — - — - No.200 3 30 - -- - - --- - ---- --- - - - --- -_ -- --- 20 _--_-- — -- — ---_ �_— 10'— _ 0 1" 1/2" #4 #10 #20 #40 #60 #100 #200 Sieve Size 3" 2" Material •" • • • Client: Gayness Engineering Group Ltd. 3701 East Tudor Rd. Anchorage, AK, 99507 Project: 2022 Testing Sample Details Sample ID 22 -0113 -SO2 General Location Rock Hill: B2, L28 Location T.H. 2 - 6ft Project Code: 220453 CC: david Gamess Maria Kampsen Particle Size Distribu 100 60 20 t 100 ' 90 80 70 N N E 60 rn c 50 a ca m 40 a� a) o- 30 20 10 0 Sieve Size 3" 2` reproduced, except in full, without the Alaska Testlab - Anchorage 4040 B Street, Suite 102 Anchorage, AK 99503 Phone: 907-205-1987 Fax: 907-7824409 info@alaskatestlab.com ns tested below. this report should not be approval of Alaska Tesllab or the agency. +4—p-Z Reviewed By: Maria E Kampsen Title: Senior Engineer Date: 2/15/2022 Other Test Results °/d Passing Limits Description Method Result Limits Group Code ASTM D2487 GW Group Name Well -graded gravel with sand Atterberg Limits Estimated Yes Tested By Cindy Zickefoose Date Tested 2/15/2022 Method ASTM D6913 A Preparation Method Oven Dry Composite Sieving? Yes Separating Sieve(s) No. 4 Fractional Mass Retained (%) 0.00 Cu ASTM D2487 20.77 :ion Method: ASTM D6913 Diameter Drying By: Oven 6 2 600 200 100 50 Date Tested: 2/15/2022 mm --; pm t Tested By: Cindy Zickefoose 1" 1/2" #4 #10 #20 #40 #60 #100 #200 Sieve Size °/d Passing Limits 3in 100 tin 100 1 % in 100 lin 87 %in 79 'Y2in 68 3/8in 60 No.4 45.2 No.10 30 No.20 17 No.40 9 No.60 5 No.100 3 No.200 2 Comments_ _. Sample Size Does Not Meet ASTM Requirements Soil Classification of Fines (4200) in Sieve Analyses Assumed Unless Verified by Additional Testing 'arm No: 18909, Report No: MAT:22-0113-502 © 2000.2022 QESTLab by SpectraQEST.com Pano of ' ---ATL Material•' • 1 Client: Garness Engineering Group Ltd. 3701 East Tudor Rd. Anchorage, AK, 99507 Project: 2022 Testing Sample Details Sample ID 22-0113-S01 General Location Rock Hill: B2, L28 Location T.H. #2 8 Ft Particle Size Distri 100 60 20 100 90 80 70 toN E 60 ta U) 50 o. co c 40 U N 0 30 20 10 0 Sieve Size 3" 2" Alaska Testlab - Anchorage 4040 8 Street, Suite 102 Anchorage, AK 99503 Phone: 907-205-1987 Fax: 907-782-4409 info@alaskatestlab.com Project Code: 220453 The results contained bok-pertain only to the items tested below. This report should not be reproduced, except in full, without the prior written approval of Alaska Testlab or the agency. CC: david Gamess Maria Kampsen bution Method: ASTM D6913 Diameter Drying By: Oven ' 6 2 600 200 100 50 Date Tested: 2/15/2022 min -- -- I pm —{ Tested By: Cindy Zickefoose 1" 1/2" #4 #10 #20 #40 #60 #100 #200 Sieve Size Reviewed By: Maria E Kampsen 3in 100 Title: Senior Engineer 100 Thin Date: 2/15/2022 lin Other Test Results '/in Description Method Result Limits Group Code ASTM D2487 SP -SM Group Name Poorly graded sand with silt and gravel Atterberg Limits Estimated Yes Tested By Cindy Zickefoose Date Tested 2/15/2022 Method ASTM D6913 A Preparation Method Oven Dry Composite Sieving? Yes Separating Sieve(s) No. 4 Fractional Mass Retained (%) 0.00 Cu ASTM D2487 20.42 bution Method: ASTM D6913 Diameter Drying By: Oven ' 6 2 600 200 100 50 Date Tested: 2/15/2022 min -- -- I pm —{ Tested By: Cindy Zickefoose 1" 1/2" #4 #10 #20 #40 #60 #100 #200 Sieve Size % Passing Limits 3in 100 tin 100 Thin 100 lin 97 '/in 95 '/zin 87 3/8in 81 No.4 66.3 No.10 53 No.20 39 No.40 28 No.60 18 No.100 10 No.200 5 e ©mmrits' Sample Size Does Not Meet ASTM Requirements Soil Classification of Fines (-#200) in Sieve Analyses Assumed Unless Verified by Additional Testing Vo Plasticity Index Test Performed orrrt No: 18909, Report No: MAT:22.0113-Sol O 2000-2022 QESTLab by SpectraQESTcom E3,-- 4 ,.a 0 0- z 2 LJ4' uj F R C ro 2 R