Loading...
HomeMy WebLinkAboutLEWIS & CLARK LT 9Onsite File lark ewis C x MUNICIPALITY OF ANCHORAGE Development Services Department Phone: 907-343-7904 On-Site Water & Wastewater Section Fax: 907-343-7997 Pump Installation Log Well Drilling Permit Number: _______________ Date of Issue: ____-____-____ Parcel Identification Number: ____-____-____ Legal Description Block Lot Property Owner Name & Address: Pump Installation Date: _____-_____-_____ Pump Intake Depth Below Top of Well Casing: __________ feet Pump Manufacturer’s Name: ___________________________ Pump Model: _____________________________________ Pump Size: ____________hp Pitless Adapter Burial Depth: _________ feet Pitless Adapter Manufacturer’s Name: _________________________ Pitless Adapter Installer: ____________________________ Well Disinfected Upon Completion? XX Yes No Method of Disinfection: _____________________________ Comments: Pump Installer Name: __________________________________ Company: ___________________________________________ Mailing Address: ______________________________________ City: ___________________ State: __________Zip: _________ Attention: The pump installer shall provide a pump installation log to On-site within 30 days of pump installation. MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program Xo fien t Se PO Box 196650 4700 Elmore Road i Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite Department On -Site Water & Wastewater System Permit Permit Number: OSP231350 Effective Date: 11/22/2023 Work Type: WellSeptic Renewal Expiration Date: 11/21/2024 Tax Code Number: 01707473000 Site Legal Address: LEWIS & CLARK LT 9 G:2941 Site Mailing Address: 8812 PATHFINDER CIR, Anchorage Owner: PARYAVI EBRAHIM Lot Size in Sq Ft: 75246 Design Engineer: PANNONE ENGINEERING SERVICES Total Bedrooms: 2 This permit is for the construction of: Q Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy Q Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Re e y: / 15G Op to Date: Issued By: Date: ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 017-074-73 Property owner(s) Ebrahim Paryavi Day phone Mailing address 13434 Alpweg Anchorage, AK Site address NHN Pathfinder Circle Legal description (Sub'd., Block & Lot) Lewis & Clark L9 Legal description (Township, Range & Section) Lot Size 75,246 Sq. Ft. Number of Bedrooms 2 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (N all that apply) Absorption Field X❑ Initial ❑ Single Family (SF) X❑ Septic Tank X❑ Upgrade ❑ (w/wo ADU) Holding Tank ElRenewal ❑X Duplex (D) ❑ Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well X❑ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: Waiver Fees: Date of Payment: (t 2 13 Date of Payment: Receipt Number: 0 0 r G Receipt Number: Permit No. 0 5 P Z3 t S Waiver No. Permit App_'- : :-'.,'c Pannone Engineering Services LLC Steven R. Pannone, Principal Registered Professional Engineer E‐mail: steve@panengak.com Mailing: P.O.Box 1807, Palmer, AK 99645 Telephone: (907) 745‐8200   FAX: (907) 745‐8201 28 September 2023 Subject:   Lewis & Clark L9          Well and Septic System Permit Request     Design Narrative This is a design narrative for a permit to install a well and septic system to be issued for this property. The proposed systems will serve a proposed 2 br House. Currently the lot is undeveloped.  This lot and surrounding lots will be served by private wells. Currently there are no wells within 100 feet of the proposed system. 1. Soils. Pannone Engineering Services, LLC performed a test hole on this lot on 4/30/2021, and groundwater was monitored for at least seven days. Ground water was observed to a depth of 2.0' below the ground surface in the test hole monitor tube on 5/11/2021. Bedrock was not encountered in the test hole. Based on the results of the percolation tests, overall soils appearance and the selection of the proposed drain field; an application rate of 4.0 gallons/day/square feet was used for an advanced wastewater treatment system. 2. Soil Absorption System Design. a. See Sheet 1 of the design package. 3. Surface Water: There is no surface water within 100 feet of the proposed septic tank and drain field. The proposed drain field upgrade will maintain at least 100 feet from all surface water. 4. Topography: See attached site plan for area topography. 5. Drawing Markings: The Drawings are marked “For MoA Review Only”. When written notification that the review is complete and no further comments are received from MoA On‐Site Department, the note will be removed and “For Construction” drawings will be issued. The proposed installation will not affect the future development of this or the surrounding lots. If you have any questions or concerns, please contact me at 745‐8200. Sincerely, Steven R. Pannone, P.E. Owner/Civil Engineer Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP231350, Deb Wockenfuss, 11/22/23 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP231350, Deb Wockenfuss, 11/22/23 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP231350, Deb Wockenfuss, 11/22/23 PA N N O N E E N G S V C , L L C ( C . I . 1 0 8 8 ) COMMENTS: Test hole excavated by BROWNSON BROS. PERFORMED BY: Joseph Lawendowski. I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDLINES IN EFFECT ON THE DATE OF THIS TEST. ·16 (min/inch) ·6" ·2 FT AND 3 FT SOILS LOG INSTALL SEPTIC SYSTEM PER ATTACHED PLANS. INSTALL WELL 2 FEET 2 FEET Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP231350, Deb Wockenfuss, 11/22/23 MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.mUni.org/onsite On -Site Water & Wastewater System Permit Permit Number: OSP211166 Work Type: WellSeptic Initial Tax Code Number: 01707473000 Site Legal Address: LEWIS & CLARK LT 9 G:2941 Site Mailing Address: Owner: PARYAVI EBRAHIM Design Engineer: PANNONE ENGINEERING SERVICES This permit is for the construction of: Effective Date Expiration Date: Lot Size in Sq Ft Total Bedrooms: 1ent Department 6/7/2021 6/7/2022 75246 Q Disposal Field CEJ Septic Tank ❑ Holding Tank ❑ Privy Q Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing 4 Special Provisions: ** Additional test holes are required to be done prior to the construction of the septic field. Construction may proceed at your own riskbefore the 7 day water monitoring is complete. Please submit stamped and signed results with the As -built Inspection Report. If the results require a designchange, construction of the system will stop pending On -Site review andapproval. Received By: Date: Issued By: Date: MUNICIPALITY, F ANCHORAGE Community Development DepartmentPhone: 907-343-7904 Development Services Division` Fax: 907-343-7997 On -Site Water & Wastewater Program ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 017-074-73 Property owner(s) Ebrahim Paryavi Day phone Mailing address 13434 Alpweg Anchorage, AK Site address N H N Pathfinder Circle Legal description (Sub'd., Block & Lot) Lewis & Clark L9 Legal description (Township, Range & Section) Lot Size 75,246 Sq. Ft. Number of Bedrooms 4 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (® all that apply) Absorption Field X❑ Initial 0 Single Family (SF) Q (w/wo ADU) Septic Tank Q Upgrade ❑ Duplex (D) ❑ Holding Tank ❑ Renewal❑ Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well 0 Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance: - I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: 3'2o Waiver Fees: Date of Payment: 2 Date of Payment: Receipt Number: 73 S/ Receipt Number: Permit No. n S /0 2 / l 1,6 ( Waiver No. Permit App_-'- :• Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP211166, Deb Wockenfuss, 06/07/21 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP211166, Deb Wockenfuss, 06/07/21 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP211166, Deb Wockenfuss, 06/07/21 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP211166, Deb Wockenfuss, 06/07/21 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP211166, Deb Wockenfuss, 06/07/21 GARNESS ENGINEERING GROUP, Ltd CIVIL & ENVIRONMENTAL ENGINEERS 370, ETUDOR ROAD. SURE 101•AN--KORAGE.AK025D7• PHONE 0071 337-6170- FAX (977) 33 MA •%ZSSITE:-pmrsalgi,ce aron1 SOIL LOG - PERCOLATION TEST LEGAL DESCRIPTION: LEWIS AND CLARK SID ( f e - Lo+ q PERFORMED FOR: BIG COUNTRY ENTERPRISES, LLC / S4 GROUP DATE: 1/2/2015 DEPTH — (feeq ORGANICS TEST HOLE #17 1 PAGE 1 OF 2 E 9 10 11 12 13 14 15 16 17 18 19 1L TO GM HARDPAN) DEPTH TO GROUNDWATER DATE DRY 1/2/2015 SOIL CLASSIFICATIONS 2-1 DRY 4117f2015 GM TO SM GW O. 3 — W/ SOME SILT GPIllllllllML 1111111 CL 4 (SMEARING) GC OL SWIIIMH II1111 Wmn • %//%.CH • I .J ►+SC E 9 10 11 12 13 14 15 16 17 18 19 1L TO GM HARDPAN) DEPTH TO GROUNDWATER DATE DRY 1/2/2015 14' 1/16/2015 DRY 4117f2015 N SCALE: 1."= 1w DATE READING CLOCK TIME NET TIME WATER LEVEL NET DROP (MINUTES) READING (INCHES) 11512015 1 2:50 - 6- - 2 3:20 30 6- 0 - STOPPED READINGS PERCOLATION RATE >120 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN 5 FT. AND 6 FT. 20 A FOUR HOUR PRESOAK WAS PERFORMED: E YES ❑ NO SOILS LOGGED BY: ROB CAMPBELUJODY MAUS PERCOLATION TEST PERFORMED BY: DAVID GARNESS COMMENTS: PERCOLATION READINGS ARE WITHIN 1/16 OF INCH. PERFORMED BY GEG, Ltd. 1, JEFFREY A. GARNESS, CERTIFY THAT THIS WAS PEffORNIED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: _412, 4 _ sW.WA"Ax.»r AR ESS ENGINEERING GROUP9 Ltd CIVIL & ENVIRONMENTAL ENGINEERS -- 3701 E. TUDOR ROAD. SURE 101 ' MCHORAGE. AK 99507' PHONE (907) 337-6179' FAX (907) 33&W46' V?US1TE: anvvy�+�xawg'vreaAnS wm SOIL LOG - PERCOLATION TEST LEGAL DESCRIPTION: LEWIS AND CLARK SID PERFORMED FOR: BIG COUNTRY ENTERPRISES, LLC /S4 GROUP DATE: SEE PAGE 1 OF 2 DEPTH TEST HOLE #17 (feet) 1 1PAGE 2OF2 2 CLOCK TIME SOIL �:o; .. .... .o.:� CLASSIFICATIONS ORG - GW 339 6" GP ML 3 30 2' GM CL 4:09 OZe GC OL 4 30 2" 4' 5 4:39 - 6" SW MH 5:09 30 •* ° i i SP CH 5 O SM '.,'OH Q SC 6 _U 7— LL. 8 U 9 J_ O 10 n_ 11 0 LL CV 12 0 13 W 0 14 Q IZ W 15 LU 16 17 18 2 V Z LL U7 it LL CL R DEPTH TO DATE GROUNDWATER 1 E �'e®®'muxmx% kk .r 49 ....... ..................... .....:-pz. 1�ua A. Ess L/ E-795$ ®gym m�� I G� N 5 SCALE: 1' =100' DATE READING CLOCK TIME NET TIME (MINUTES) WATER LEVEL READING NET DROP (INCHES) 1/14/2015 1 339 6" 2 4:09 30 2' 4' 3 4:09 6' - 4 4:39 30 2" 4' 5 4:39 - 6" 6 5:09 30 2" 4" PERCOLATION RATE 7.5 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) 19 TEST RUN BETWEEN 2 FT. AND 3 FT. 20 A FOUR HOUR PRESOAK WAS PERFORMED: f YES ❑ NO SOILS LOGGED BY: SEE PAGE 1 OF 2 PERCOLATION TEST PERFORMED BY: ROD CAMPBELL COMMENTS: PERCOLATION READINGS ARE WITHIN 1/16 OF INCH. PERFORMED BY GEG, Ltd. I, JEFFREY A. GARNESS, CERTIFY THAT THIS WASP RFOR ED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: // va PUE Easement per u „ 109.43 co 1I W V -is PO pCc C� l w1 C do N NO 3C c�. c l r- m C J h! ! x r' L I i o LA n 10-1 Co Cil F— O L Crp` N N � { �.! Doo W � 00 O� tri Cil Qo M CDt X7.28' -- ---- — -- -- -.– — — -- -.-. -- 302.00' N00'00'00" `. 888.52, PUE Easement per u „ MUNICIPALITY OF ANCHORAGE ADVANCED WASTEWATER TREATMENT SYSTEM MAINTENANCE AND REPAID AGREEMENT THIS MAINTENANCE AND REPAIR AGREEMENT, herein the "AGREEMENT" made and entered into as of this `j V Day of 11 of 20_x, by and between �� %•�` .^ ����"���� r; herein the "OWNER," and the Municipality of Anchorage. herein the "MUNICIPALITY", in accordance with Anchorage Municipal Code (AMC) 15.65.365. In consideration of the mutual covenants contained herein, the parties to this Agreement agree as follows: 1. Advanced Wasteivater Treatment Systems. The Municipality grants permission to the Owner to utilize and operate an Advanced Wastewater Treatment System (AWWTS), described as AJyo, V)feX located at (legal description) L cusj j t Clark Lt 2. Maintenance. Repairs and Alterations. (Owner is required to read, understand and initial each section) Throughout the term of this Agreement, the Owner shall enter into a service agreement with an AWWTS service and maintenance provider approved by the Municipality or the manufacturer's representative. The AWWTS shall be maintained in a satisfactory condition capable of performing as designed and producing treated septic effluent in accordance with the equipment's approval .for operation in the Municipality. It shall be the responsibility of the Owner during the term of this Agreement to pay for all repair(s), maintenance, adjustment(s), replacement costs, and inspection costs. This includes an annual maintenance fee (typically $400 to $600). �n Owner agrees that only maintenance and repair personnel approved by the Municipality or the manufacturer's representative will inspect and make any necessary maintenance, p repairs or permitted alterations to the system. Sf Owner acknowledges that regular maintenance of an AWWTS reduces the potential failure of the system, which could include sewage backup and costly repairs or drainfield replacement. (rev. 05/18/2018) Page 1 of 3 Owner acknowledges that the Municipality may request records of maintenance and repairs from the manufacturer's representative or maintenance provider. 1 Owner acknowledges that the fine for failing to maintain and repair an AWWTS may be assessed in accordance with AMC 14.60.030. L Owner agrees to grant the Municipalityreasonable access to test and inspect the AWWTS. The Municipality will give at least 24-hour notice. C n Owner agrees that any sale or transfer of title of the property will not occur without a new -�— Certificate of On -Site Systems Approval. 5 Owner agrees that the AWWTS installation and maintenance requirements as provided by the AWWTS vendor/installer and approved by the Municipalit;, are the governing guidelines for the construction; maintenance and repair of the Owner's AWWTS. (� Owner agrees to maintain remote monitoring of the AWWTS as required by the AWWTS approval. 3. Term. The term of this Agreement shall begin on the date of approval by the Municipality to operate the installed system; or upon transfer of title, and shall continue while the AWWTS is operational or until title is transferred. 4. Nonwaiver. The failure of the Municipality at any time to enforce a provision of this Agreement shall in no way constitute a waiver of the provisions; nor in any way affect the validity of the Agreement or any part hereof, or the right of the Municipality thereafter to enforce every provision hereof. 5. Amendment. This Agreement shall only be amended by authorized representatives of the Owner and Municipality. Any attempt to amend this agreement by either an unauthorized representative or unauthorized means shall be void. 6. Jurisdiction: Choice of Law. Any civil action arising from this Agreement shall be brought in the Superior Court for the Third Judicial District of the State of Alaska at Anchorage. The lavas of the State of Alaska shall govern the rights and obligations of the parties under this Agreement. 7. Severability. Any provisions of this Agreement decreed invalid by a court of competent jurisdiction shall not invalidate the remaining provisions of the Agreement. (rev. 05/18/2018) Page 2 of 3 OWNER: } By: (signature) Date: �r� cz�� i i'�� �� �`�•_V u (print name) STATE OF ALASKA ) SS. THIRD JUDICIAL DISTRICT ) The foregoing instrument was aclaiowledged.before me this I I day of 20 1,by -GI9-�ri-hvN,� Pc�rte�.v OTARY PUBLIC FOR ALASKA nlPaoliD My Commission expires: r7„_Ccmmis:;cn@a ;i�"ry C�;:im: C7/2�12C �: MUNICIPALITY: By: �(r�fi (signature) (print name) (rev. 05/18/2018) Date: Z� Z Title: Page 3 of 3