Permit Number: SW990197 PID Number: 041-033-01
Name:
CHRIS BEHEIM
Wastewater System: ■ New ❑ Upgrade
Y pg
Address:
4904 DEARMOUN , ANCH, AK 99516
ABSORPTION FIELD
Phone:
No. of Bedrooms:
(907) 345-1761
4
❑ Deep Trench ■ Shallow Trench ❑ Bed ❑ Mound ❑ Other
LEGAL DESCRIPTION
Soil Rating:
1.2
Total Depth from original grade:
8.2-8.7
GPD/Sq. Ft.
Ft.
Lot: Block: Subdivision:
Depth to pipe bottom from original grade:
Gravel depth beneath pipe:
2 2 HILLSIDE NORTH #6
4.0 Ft.
4.4 Ft.
Township:
Range:
Section:
Fill added above original grade:
Gravel length:
—
—
—
0 — .25 Ft.
57 FL
WELL: ■ New ❑ Upgrade
Gravel width:
5
Number of linea:
1
Distance between lines:
—
FL
Ft.
Classification (Private, A,B,C):
PRIVATE
Total Depth:
265
Cased To:
44
Total absorption area:
570
Pipe material:
ASTM D -3034/F-810
Ft
Ft.
SQ. Ft.
Driller.
ALPINE DRILLING
Date Drilled:
8/1/99
Static Water Level:
40
Installer.
GROENWIG
Dateins ailed:
828/99-8/30/99
Ft.
Yield:Pump
4
Set At:
Casing Height Above Ground:
TANK
GPM
UNKNOWN FL
2 Ft.
SEPARATION DISTANCES
■ Septic ❑ Holding ❑ S.T.E.P.
To
Septic
Absorption
Lift
Holding
Public/Private
Manufacturer.
ANCHORAGE TANK
Capacity in gallons:
1250
From
Tank
Field
Station
Tank
Sewer Linea
Well
100'+
100'+
100'+
—
25'+
Material:
STEEL
Number of compartments:
2
Surface
Water
100'+
100'+
100'+
-
-
LIFT STATION
LotSize
5'+
10'+
5'+
—
—
in gallons:
Manufacturer.
Line
5'+
10'+
"Pump on" level at: "Pump o at
High water alarm at:
Foundation
—
—
—
Curtain—Pump
Make a:
Electrical Inspections performed by:
DrainNONE
KNOWN
Remarks: FINAL GRADING AND ADDITIONAL COVER OVER
BENCH MARK
Location and Description:
THE SEPTIC TANK TO BE PERFORMED IN THE
BOTTOM OF TANK AT INLET = 100.00'
SPRING OF 2000.
TOP OF WELL HEAD = 122.62'
Assumed Elevation:
Ft.
ENGINEER'S SEAL
000�DOp �/
o� • F�op4
QQ'`P /�•� ; �� .5,000
O
i
Inspections performed by: AWWC, INC. Dates: 1st 8/28/99
2nd 8/30/99 ,...
9/1/99
•
.r;'ess;.
•fC
3rd
Je r A. Ga.
Department of Health and Human Services approval
Q • —7953 mQ�
�9-s •'• J ••'
Reviewed and approved by: Pe --t Date:4��4edP
ticQO
,•• o\��o
�ofession
,00
oO�000�00
72-013 (Rev. 9/91) MOA 25
PERMIT NUMBER: AS -BUILT DRAWING PARCEL ID NUMBER:
SW990197 041-033-01
100' WELL RADIUS 1
I_
BOTTOM OF TANK
AT INLET = 100.00
& TOP OFV II=
HEAD =122.62
-FINN, Qum -
109.25 -108.52
WffoM Gr MONK
RM -99,60
INVERT or PIPE
-109,00
DBL1
,hD.BL2
TN#1 -(
Tvip \ \
MT \ \\
\ CO2
OWWL GKME -
V 1250 GALLON
SEPTIC TANK
NEW DRAINFIELD
10782 10831 / [IIAL GRAM - 102,02
5f] 5f2
- fop or f"
Ar IN Ef -1 09.835 r__
I I NSW 1250 GALLON
INVERTOFPIPE 5�p11C TANK
A11N.Ef - 109,h7
ALASKA WATER AND WASTEWATER CONSULTANTS, INC.
6901 DEBARR ROAD, SUITE 28. ANCHORAGE, AK. 99504
PHONE: (907) 337-6179/FAX: (907) 338-3246
LEGAL DESCRIPTION:
HILLSIDE NORTH SUBDIVISION #6, LOT 2, BLOCK 2
TYPE OF WORK:
DESIGN OF SEPTIC SYSTEM UPGRADE
PREPARED FOR: PHONE NUMBER:
CHRIS BEHEIM 345-1761
DATE: 10/23/99 DRAWN BY: SCALE: PAGE:
REVISED 1/13/2000 K.D.W. 1 = 40' 2 OF 2
/--TOP OF f"
Af OUTL1 f- 104B4
`INVERT of PIPE
AfOn1 r-104.19
0001 F
�
�• �H '
- D
f •i r y •A�Garness;
. 1 7953
9iS •'• 1 •'••,eCO�O
�4eo
Pro fessionoo
��4000�oa
A
I B C D
ST1
24.9
13.8 — —
ST2
30.5
21.9 — —
DBL1
34.2
26.9 — —
DBL2
31.6
29.1 — —
001
37.9
30.4 — —
0O2
—
— 64.1 91.4
57.5 91.0
BOTTOM OF TANK
AT INLET = 100.00
& TOP OFV II=
HEAD =122.62
-FINN, Qum -
109.25 -108.52
WffoM Gr MONK
RM -99,60
INVERT or PIPE
-109,00
DBL1
,hD.BL2
TN#1 -(
Tvip \ \
MT \ \\
\ CO2
OWWL GKME -
V 1250 GALLON
SEPTIC TANK
NEW DRAINFIELD
10782 10831 / [IIAL GRAM - 102,02
5f] 5f2
- fop or f"
Ar IN Ef -1 09.835 r__
I I NSW 1250 GALLON
INVERTOFPIPE 5�p11C TANK
A11N.Ef - 109,h7
ALASKA WATER AND WASTEWATER CONSULTANTS, INC.
6901 DEBARR ROAD, SUITE 28. ANCHORAGE, AK. 99504
PHONE: (907) 337-6179/FAX: (907) 338-3246
LEGAL DESCRIPTION:
HILLSIDE NORTH SUBDIVISION #6, LOT 2, BLOCK 2
TYPE OF WORK:
DESIGN OF SEPTIC SYSTEM UPGRADE
PREPARED FOR: PHONE NUMBER:
CHRIS BEHEIM 345-1761
DATE: 10/23/99 DRAWN BY: SCALE: PAGE:
REVISED 1/13/2000 K.D.W. 1 = 40' 2 OF 2
/--TOP OF f"
Af OUTL1 f- 104B4
`INVERT of PIPE
AfOn1 r-104.19
0001 F
�
�• �H '
- D
f •i r y •A�Garness;
. 1 7953
9iS •'• 1 •'••,eCO�O
�4eo
Pro fessionoo
��4000�oa
Mu ci ali oi" A�nehora e
p tY g
tment of Health and H i Services
825 "L" Street
".0. Box 196650 Anchorage, Alaska 9.,
Rick Mystrom http://www.ci.anchorage.a k. us
Mayor
Permit Number: #SW 990197 Date of Issue: 7-16-99 Parcel Identification Number: 041-033-01
Date Started: 8-1-99 Date Completed: 8-1-99 Is well located at approved permit location? N Yes ❑ No
Legal Descriptio : Hillside North # 6BIk 2 Lt 2
Property Owner Name & Address: Chris Beheim
"3OLP 48-4 De Armoun Road
Anchorage, Ak 99516
Borehole Data: Depth (ft)
Method of Drilling N air rotary ❑ cable tool
Soil Type, Thickness & Water Strata From To
Casing type: Steel
stick-up 0 2
Wall Thickness: .25 inches
gravelly silt 2 6
Diameter: 6 inches Depth: 44 feet
sand 6 11
Liner Type:
gravelly silty sand 11 15
Diameter: inches Depth: feet
Casing stickup above ground: 2 feet
sandy gravel 15 41
Static water level (from ground level): 40 feet
bedrock 41 265
Pumping level: 265 feet after
2 hours pumping 4 gpm
Recovery Rate: 4 gpm
Method of Testing: airlift
r'
Well Intake Opening Type:
❑ Open End N Open Hole
S� of,�ch�eC�tces
an
❑ Screened Start feet Stopped feet
hjk�JViclpau
❑ Perforations Start feet Stopped feet
Grout Type: Bentonite # 8 Volume: 1 bag
oep�`'Hea`to
Depth: Start 0 feet Stopped - feet
Pump: Intake Depth feet
Pump size hp Brand Name
Well Disinfected Upon Completion? N Yes ❑ No
Method of Disinfection: Clorox
Comments:
Well Driller: Alpine Drilling & Enterprises
P.O. Box 110496
Anchorage, AK 99511
Attention: The we9ddUw-1aaav4de-a well tog to the -property -owner ivithiff3$-days of completion and the property
nxxrnar nr the xxiAl r1ri1i-Pr dinil nrn%AA- n wAl 9nrr-tn *k,, PlPn'f nf�M-nith ;e, Tfi1mnnxvithin 9(1 nave of rmmnlPtinn
.11
Ct cpm
MUNICIPALITY OF ANCHORAGE
Department of Health and Human Services
�® On -Site Services Program (� �
825 L Street, Room 502 �L Y' V l r -n
P.O. Box 196650, Anchorage, AK 99519-6650
(907) 343-4744 1
ON-SITE WASTEWATER DISPOSAL SYSTEM / WATER SUPPLY PERMIT
Initial
Permit Number: SW990197
Date Issued: Jul 16, 1999
Expiration Date: Jul 15, 2000
Parcel ID: 041-033-01
Legal Description: HILLSIDE NORTH #6 BLK 2 LT 2
Design Engineer: 0041 AK Water & Wastewater Consulta Site Address:
Owner Name: Chris Beheim Lot Size: 92783 SQ. FT.
Owner Address: 40-4 De Armoun Road Total Bedrooms: 4 Permit Bedrooms: 4
Anchorage , AK 99516 -
This permit is for the construction of:
❑✓ Disposal Field ❑✓ Septic Tank ❑ Holding Tank ❑ Privy ❑✓ Private Well ❑ Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations ( 18AAC80 ).
3. The engineer must notify DHHS at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-4744 ( 24 hours ). ( Not required for a Water Supply Permit only ).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
Received By:
Issued By:
Date: Z_ l b
Date: �� f
Alaska Water & Wastewater Consultants, Inc.
6901 DeBarr Road, Suite 2B — Anchorage, AK — 99504
(907) 337-6179 — Fax (907) 338-3246
Consulting Engineers
July 8, 1999
Municipality of Anchorage
Department of Health & Human Services
Division of Environmental Services
On -Site Services Section
P.O. Box 196650
Anchorage, Alaska 99519-6650
Ref: Well and Sewer Design for Hillside North #6, Lot 2, Block 2
To whom it may concern:
The reference property is currently undeveloped. The owner wishes to build a 4 bedroom house
with an on-site septic system and well. Two test holes were performed on the property, one by
A.W.W.C., Inc., and the other by Dee High, P.E. The soils are summarized as follows:
6
1. SOILS: A.W.W.C. Test Hole #1 was excavated to a depth of V feet and no groundwater
was encountered. There was approximately F of organics at the top of the test hole followed by
a GW layer to a depth of 7 to 8 feet. Below the GW layer to the bottom of the test hole was a
SP/SM material. One percolation test was performed in this test hole at a depth of 6 feet and the
soil absorbed water as fast as it was added. The soils encountered in the test hole performed by
Dee High, P.E. were similar as to what was encountered in A.W.W.C. test hole #1. The soils in
this test hole were also found to be less than 1 min./inch. It is our opinion that the insitu soil will
serve as a filter.
2. TRENCH DESIGN:
a. Percolation Rate: <1 minutes/inch
b. Allowable Application Rate: 1.2 gallons/day/ft
2
c. Number of Bedrooms: 4
d. Design Flow: 600 gallons per day
e. Minimum Absorption Area: 500 ft2
f. Maximum total depth: 8 - 9 feet
g. Effective Depth: 4 feet
h. Reduction Factor = 0..50
i. Width: 5 feet
j. Length: 55 feet
k. Effective absorption area = 550 ft2 (500 ft2+)
3. SURFACE WATERS: There are no surface waters within 100 feet of the proposed
upgrade.
4. TOPOGRAPHY: The entire lot has a gradual slope from east to west that is less than 25%
(see attached topography drawing). In short, there are no slope concerns.
I am unaware of any adverse impacts this installation would have on adjacent wells or septic
systems. If you have any questions, please contact me at 337-6179, or 244-9612. Thank you
for your assistance. 4
Sincerely
1
LOT 2, STUCKAGAIN
HEIGHTS #2
r Jam= \ LOT 1, HILLSIDE
r �� NORTH #3
I
LOT 5, BLOCK 2
HILLSIDE NORTH S/D #6
C ACANTD
1p0 �� PROPOSED 4
BDRM HOE E %
AWWC TH#1
II LI PROPOSED WELL
t'A TEST HOLE
. PROPOSED SEPTIC
SYSTEM (SEE DESIGN,
PAGE 2 OF 2)
1 V LOT 4, BLOCK 2
LOT 1, BLOCK 3 t � HILLSIDE NORTH S/D #6
HILLSIDE NORTH #3 Z
tC7ZAf
U
S
1
`-iiACA�
LOT 3, BLOCK 2 \
HILLSIDE NORTH S/D #6
a.
ALASKA WATER AND WASTEWATER CONSULTANTS, INC. oa0000p
6901 DEBARR ROAD, SUITE 2B. ANCHORAGE, AK. 99504
PHONE: (907) 337-6179/FAX: (907) 338-3246 0 ��' • "
LEGAL DESCRIPTION: QO �•• ••��4oQ
HILLSIDE NORTH S/D #6; LOT 2, BLOCK 2
�.... .... .......
TYPE OF WORK:
SITE PLAN .... ........
r y A. arness,:
PREPARED FOR: PHONE NUMBER: � E-7953 mQ�
CHRIS BEHEIM 345-1761 -s ••, • •• .��OQ
SCALE: PAGE: 44 fire ' • • ...... • • •�oAo
DATE: —7K
RAWN BY: 0 dprofessio��o
7/5/99 K.D.W./A.C.G. 1 = 100, 1 OF 2 ��OOO0000a
PROPOSED 1250
GALLON SEPTIC TAS
INSTALL DOUBLE
CLEAN -OUTS
PROPOSED 4 -
BEDROOM HOUSE
// PROPOSED
PRIVATE WELI
A.W.W.C. TEST
HOLE #1
PROPOSED TRENCH 5' WIDE
BY 55' LONG BY 8' - 9' I I
DEEP. ADD 4' OF CLEAN, I I
WASHED SEWER DRAINROCK. I I I I \
II II �
II II �
II
TEST HOLE PERFORMED BY I I I I�
ALTERNATE SITE
DEE HIGH, P.E. ON 1/26/99 I I
(SEE ATTATCHED SOIL LOG) 6 I _
fes, •""" -�� �- _.� ��
_ wf
�--- 20, pRp1NAGE FJ+SEN✓ v.--- -•-- a .
s
U
Cc/ NOTE: THE TRENCH SHALL
BE INSTALLED PARALLEL TO
THE SLOPE CONTOURS.
C� 1
ALASKA WATER AND WASTEWATER CONSULTANTS, INC. �F O
6901 DEBARR ROAD, SUITE 2B. ANCHORAGE, AK. 99504 0 G , � 044
PHONE: (907) 337-6179/FAX: (907) 338-3246 ��a4. ••' • • • • ;�'...• O
LEGAL DESCRIPTION: • ••
HILLSIDE NORTH SUBDIVISION #6, LOT 2, BLOCK 2 O'.•• . • .H.../ ,•••, .,_„�0��
TYPE OF WORK: D
DESIGN OF SEPTIC SYSTEM UPGRADE•• ••••• ••
•e • A. Garness�
PREPARED FOR: PHONE NUMBER: �o49�s:•. _7953 .•,:�cOQ�
CHRIS BEHEIM 345-1761 .
DATE: DRAWN BY. SCALE: PAGE:
�� 44�e^eC P • " • " o&
7/5/99 A.C.G. 1 = 40' 2 OF 2 rofessi0� o��
�40000��
i
i
i
i
PROPOSED 1250
GALLON SEPTIC TAS
INSTALL DOUBLE
CLEAN -OUTS
PROPOSED 4 -
BEDROOM HOUSE
// PROPOSED
PRIVATE WELI
A.W.W.C. TEST
HOLE #1
PROPOSED TRENCH 5' WIDE
BY 55' LONG BY 8' - 9' I I
DEEP. ADD 4' OF CLEAN, I I
WASHED SEWER DRAINROCK. I I I I \
II II �
II II �
II
TEST HOLE PERFORMED BY I I I I�
ALTERNATE SITE
DEE HIGH, P.E. ON 1/26/99 I I
(SEE ATTATCHED SOIL LOG) 6 I _
fes, •""" -�� �- _.� ��
_ wf
�--- 20, pRp1NAGE FJ+SEN✓ v.--- -•-- a .
s
U
Cc/ NOTE: THE TRENCH SHALL
BE INSTALLED PARALLEL TO
THE SLOPE CONTOURS.
C� 1
ALASKA WATER AND WASTEWATER CONSULTANTS, INC. �F O
6901 DEBARR ROAD, SUITE 2B. ANCHORAGE, AK. 99504 0 G , � 044
PHONE: (907) 337-6179/FAX: (907) 338-3246 ��a4. ••' • • • • ;�'...• O
LEGAL DESCRIPTION: • ••
HILLSIDE NORTH SUBDIVISION #6, LOT 2, BLOCK 2 O'.•• . • .H.../ ,•••, .,_„�0��
TYPE OF WORK: D
DESIGN OF SEPTIC SYSTEM UPGRADE•• ••••• ••
•e • A. Garness�
PREPARED FOR: PHONE NUMBER: �o49�s:•. _7953 .•,:�cOQ�
CHRIS BEHEIM 345-1761 .
DATE: DRAWN BY. SCALE: PAGE:
�� 44�e^eC P • " • " o&
7/5/99 A.C.G. 1 = 40' 2 OF 2 rofessi0� o��
�40000��
4 , - :-7,,,.,2i
ALASKA WATER & WASTEWATER CONSULTANTS, INC.
690PHONEARR (0) 337-6179 UITE *B FAX (903 ANCHORAGE, 9504
3246
SOIL LOG — PERCOLATION TEST
LEGAL DESCRIPTION: HILLSIDE NORTH SUBDIVISION #6, LOT 2, BLOCK 2
PERFORMED FOR: CHRIS BEHEIM
DATE PERFORMED: 6/11/99
DEPTH - TEST HOLE # 1
(feet) ORGANICS
6
3
4
5
6
7
8
9
10
12
13
14
15
16
17
18
19
20
COMMENTS:
GW
SP/SM
W/ SOME GRAVEL
SOIL CLASSIFICATIONS
a•: -:c
GW_
j ORG
__
GPII
III ML
I I I�/
GM
7
1 %,. CL
7%
i``'I'
°tea a r
GC
SW
j. OL
II L MH
� `
N a es ce
SP
,/s`// CH
-TTM
SM
_
`�%'��i OH
Z
SC
DEPTH TO
GROUNDWATER
DATE
DRY
6/11/99
DRY
6/18/99
SITE P
/ X
AWWC TH#1�
I
r
r r
CLOCK
NET TIME
LEV
DATEI READING I TIME I (MINUTES) I WATER READING ELI
(INCHES)
I I PERK HOLE ABSORBED WATER AS FAST AS IT WAS ADDED I
PERCOLATION RATE <1 (MIN./INCH)
TEST RUN BETWEEN 6.0 FT. AND
PERC. HOLE DIA
7.0 FT.
6 (INCHES)
PERFORMED BY ALASKA WATER & WASTEWATER. I, JEFFREY A. GARNESS, CERTIFY THAT THIS
WAS PERFORIOED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON
DATE: - �/
J . `
Municipality o1 Anchorage �� „ • ��• � � �� • , �•�'*
.� DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L•' Street, Anchorage, Alaska 99502-0650 t
' SOILS LOG — PERCOLATION TEST
LUT Z 0(Lt_ S r O IF_ No 7L'h-k� S u c3 .
PERFORMED FOR: Af>it, t n5O Cv DATE PERFORMED: nx+Sr�j,rfiF
LEGAL DESCRIPTION: no EtF e- Cr- Fwo Township, Range, Section:
1(RrT SLOPE SITE PLAN
14
15 -
nl 0 TerST r # T
16
17
18
19-
20-
COMMENTS
920
COMMENTS
Rcadin.
Date
Grosz
Time
Net
Time
Depth to
Water
Net
Bron
l ZS -q4
I2:OD
'
✓�
2
�u
N
3
�p
4
5
••
--
--P �-n-r
6
o•oo�
7
:6 ''
►" p -C Co L1ES
�/-get.
8Sin)
N6.n
b
10
•
W I 't l-1
6714AVE
WAS GROUND WATER O
ENCOUNTERED?
11
e
#,,3 ft
IF YES. AT WIIAT
S
—
L
12
DEPTH? N��
O
•
Arj SPnfQ
—
E
13
Depth to Water Aller
"
Monitoring? Nor-st Date: Z-21-01 4
14
15 -
nl 0 TerST r # T
16
17
18
19-
20-
COMMENTS
920
COMMENTS
Rcadin.
Date
Grosz
Time
Net
Time
Depth to
Water
Net
Bron
l ZS -q4
I2:OD
O 10
�u
• Ip
�p
PERCOLATION RATE Q0 SVe0fj05
)1"G%1 `tt
(m�nt+teaemchf PERC HOLE DIAMETER
TEST Z?4-8-E+ IEEN �J S FT AND S• s FT
PERFORMED BY:
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT OZ
72-008 (Rev, eip5)
v
CERTIFY THAT THIS TEST WAS PERFORMED IN
DATE:
MUMC�PAUTY OF
Development Services Department
On -Site Water & Wastewater Section
Parcel I.D. 041-033-01
Certificate of On -Site Systems Approval
1. GENERAL INFORMATION
Complete legal description HILLSIDE NORTH #6
Phone: 907-343-7904
Fax: 907-343-7997
Expiration Date: 10 "1 (19 -2-1
K2.LOT 2
Location (site address) 6910 CATINE CIRCLE, ANCHORAGE, AK 99507
Current property owner(s) CHRIS & BEVERLY BEHEIM Day phone
Mailing address
Real estate agent
6910 CATINE CIRCLE, ANCHORAGE, AK 99507
2. TYPE OF DWELLING:
® Single Family (w/wo ADU)
❑ Duplex
❑ Multiple Dwellings (Single Family and/or Duplex)
Day phone
3. NUMBER OF BEDROOMS:
4
4. TYPE OF WATER SUPPLY:
TYPE OF WASTEWATER DISPOSAL:
Private Well
®
Private Septic
Water Storage
❑
Holding Tank
❑
Community Well
❑
Community
❑
Public Water System
❑
Public Sewer
❑
Waiver request for: Distance:
Received by: Date:
COSA to be released to the engineer, unless otherwise requested by the engineer.
COSA Fee $ 550
Date of Payment �P add
Receipt Number 13
COSA # DSC
Waiver Fee $
Date of Payment
Receipt Number
Waiver #
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based
on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the
on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of
bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the
Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater
disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in
effect at the time of installation. I acknowledge that On-Site staff may visit the site to verify the information submitted.
Name of Firm FIRST WATER CONSULTING Phone 907-350-9566
Address 13030 SUES WAY, ANCHORAGE, AK 99516
Engineer's Printed Name CURTIS HUFFMAN, PE Date 6/15/2021
Comments: This investigation was completed in compliance with MOA guidelines, regulations,
and best industry practices / methods. The assessment of the condition of the well and septic
applies only to the conditions as of the day tested. The flow and absorption rates may change
due to subsurface conditions that may not be observed from the surface, changes in land use,
local soil characteristics, groundwater levels that may fluctuate during the year, quality of
construction (workmanship & materials), the water usage of the family being served by the
system and maintenance. The operational life of all well and septic systems are subject to
these various and dynamic characteristics and are outside the control of the evaluator of the P�ii • • •�;`IS��
well and septic system. Therefore, any estimate of how long a system will function satisfactory
for current or future occupants or guarantee that no unseen encroachments, deficiencies or 49 _ J
discrepancies exist can be given by First Water Consulting & FWC S ' % *' . ... ....... Ir
/ /
.... ...�::
6. DSD SIGNATURECurtis Huffman
System #1 Approved for bedrooms tc/s� . .CE 128991 .0 Age
�l1,a-+
System #2 Approved for bedrooms F�F�pROF SS O\\
Disapproved
Conditional approval for bedrooms, with the following stipulations:
O
_.
� ON-SIT ��,V� l��
�-,,"RTS A
By: Original Certificate Date:
The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the
representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is
not responsible for errors or omissions in the professional engineer's work.
7. ATTACHMENTS:
COSA Checklist X Nitrate Advisory
Septic System Advisory Arsenic Advisory
Well Flow Advisory Other 54,e&[
Legal Description: HILLSIDE NORTH #6. BLOCK 2 LOT 2 Parcel ID: 041-033-01
If more than 1 septic system on lot: COSA Checklist # _of
A. WELL DATA
® Well log is filed with Onsite (or attached)
Date drilled 8/1/1999
Total depth 265 ft
Cased to 44 ft
® Sanitary seal is functioning correctly
® Wires are properly protected
Casing height (above ground) 18 in.
Date of flow test for COSA 6/10/2021
Static water level at beginning of test 60 ft.
Well production at time of test 2.5 gpm
.• uC�7" iu'1=1
B. TANK DATA
Age of tank(s) 22 years
Tank type/material SEPTIC / STEEL
Measured operating fluid level in septic tank 50"
® Standpipes/foundation cleanout per record drawing
Date of pumping 6/10/2021.-
D. ABSORPTION FIELD DATA
Which system tested (date installed) 8/30/1999
® ALL standpipes present per record drawing
Total measured depth from grade 8.4 ft (max)
Measured depth to pipe invert from grade 4.0 ft (min)
❑ N/A — pressurized field
® Monitor tubes go to bottom of effective. If not, state
depth into effective
Structure served by this system
Water storage tank volume NA gallons
Well disinfected for coliform test? ❑ Yes ® No
® Coliform bacteria is Negative
Nitrate 0.393 mg/L
Arsenic ug/L ® Arsenic less than MRL (ND)
FWf�;
Collected by W >
Date of Sample 6/15/2021
C. LIFT STATION
❑ Required maintenance completed
Age of lift station _ years
Lift station material
Comments:
Adequacy test date 6/10/2021
Results Z Pass For 4 bedrooms
Fluid depth prior to test 0 in
Water added 600 gal
New depth 0 in
Elapsed time <1 min
® Code -required soil cover over field Final fluid depth 0 in
❑ System presoaked Absorption rate 600 gpd
(Required if vacant for greater than 30 days prior to Any rejuvenation treatment (past 12 months) N
date of test) If yes, enter date
Gallons introduced gallons FW'CS
Comments/Deficiencies: ,,.
E. SEPARATION DISTANCES
From Private Well on Lot to: (Please enter distances if less than required or if community well)
Septic Tank/Lift Station on Lot > 100'
® Yes
if No
Community Sewer Manhole/Cleanout > 100'
® Yes
if No
ft
® Yes
if No ft
Neighboring Tank > 100' ® Yes
if No
ft
Private Sewer/Septic Line > 25' ® Yes
if No ft
Absorption Field on Lot > 100' ® Yes
if No
ft
Holding Tank > 100' ® Yes
if No ft
Neighboring Absorption Fields > 100'
if No
ft
Animal Containment > 50' ® Yes
if No ft
® Yes
if No
ft
ft
If septic tank is under driveway comment below
From Absorption Field on Lot to: (Please enter distances
if
less than required)
Manure/Animal Excreta Storage > 100'
Building Foundation > 10'
Community Sewer Main > 75' ® Yes
if No
ft
® Yes
if No ft
From Septic/Holding Tank on Lot to: (Please enter distances if less than required)
Building Foundations > 10'
® Yes
if No
ft
Surface Water > 100'
® Yes if No ft
Property Line > 5'
® Yes
if No
ft
Wells on Adjacent Lots:
Absorption Field > 5'
® Yes
if No
ft
Private Wells > 100'
® Yes if No ft
Water Main > 10'
® Yes
if No
ft
Community Wells > 200'
® Yes if No ft
Water Service Line > 10'
® Yes
if No
ft
If septic tank is under driveway comment below
From Absorption Field on Lot to: (Please enter distances
if
less than required)
Building Foundation > 10'
® Yes
if No
ft
If absorption field is under driveway comment below
Property Line > 10'
® Yes
if No
_ ft
Wells on Adjacent Lots:
Water Main > 10'
® Yes
if No
ft
Private Wells > 100'
® Yes if No —ft
Water Service Line > 10'
® Yes
if No
ft
Community Wells > 200'
® Yes if No
Surface Water > 100'
® Yes
if No
ft
F. ENGINEER'S COMMENTS
G. ENGINEER'S CERTIFICATION
I certify that l have determined through field inspections and review �Are ,t`Q•: •' • •�����j
of Municipal records that the above systems are in conformance
with MOA COSA guidelines in effect on this date. TH
• ! • •
t' Curlis Huffman
/•,• CE 128991 _.•�c4�
�� `9�F�' • kJ25/21. •'���®
Septic Tank Advisory
Certificate of On -Site Systems Approval #OSC211337
Subdivision: Hillside North #6 Block 2 Lot 2
Starting at 20 years of age the MOA issues Advisory's for steel septic tanks. The septic tank for
this property is 22 years old. Typical replacement costs range from $8,000 to $11,000
This advisory must be attached to all copies of the subject Certificate of On -Site Systems
Approval.
This is an example of what the metal of a 20 -year-old steel tank MAY look like.
Mai��ng Address P O Box 196650 *Anchorage, Alaska 99519
,6650 -,*www muni org ;
0\15e
%..*4TINE C\'W
'
iv,
145 od
110.34` R•
cP
J
e.- �
8
Z
$ tK
w
O
v>�n 5 vy
co z
�
�
Q
Q
�
o�
� W
N
V
W
N
•m. V1
n.
0\15e
%..*4TINE C\'W
'
iv,
145 od
110.34` R•
cP
e�
Z
y
w
O
3La
�q
�
�
Q
Q
�
0\15e
%..*4TINE C\'W
'
iv,
145 od
110.34` R•
oz
La
3La
�q
z
z w
8T' R.240.20'
L� 1b0- g
M
\�2
2go�332 �
a
Ncr, D rff�Q CD sig
` C CV
Q: �(; 0i Q
O Aw J
C; = C5% . z • c`�
CF) W=
Yz
a
Y
m o a
_a
N p p
aeon
co 0
`�� °'C �� p C O
ca a ®m�svoo a�
3 a. LL o � -a ):2 i p .0
0toLn n•Z0Eoaa a
>h40 ��;40 Cep $ 2Q
MyQ °mac D E
C4C4�mEEO ®ao
G3 Lf) tc) MZ 0 a E 0 f 6
;0a°c®4, co
�oo 00 oc a v
O�O�
�ZaC.
E O
aE ar p _= L
s°a�ar°b v
_�o E o °a
.. x ISM
a
c
so ot
J `oce m =°a
®' ouo
d0�o ° Ee
CL e"=
J c