HomeMy WebLinkAboutLEWIS & CLARK LT 14Onsite File
Lewis & Clark
Lot 14
#017-074-78
trcev ub/uui u/
Municipality of Anchorage
On-Site Water and Wastewater Section • (907) 343-7904 Page 1 of 3
ON-SITE
WASTEWATER INSPECTION REPORT
Permit Number: OSP211205
PID Number: 017-074-78
Dwelling: ❑■ Single Family (SF)
❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: ■❑ New ❑ Upgrade
Name
Big Country Enterprises
ABSORPTION FIELD
❑ Deep Trench N] Wide Trench ❑ Bed ❑ Mound
Site Address
NHN Trailblaze Cir, Anchorage,
AK 99516
❑ Other
Phone
Number of Bedrooms
Soil Rating
depth from original grade
907-301-5359
4
1.2 GPD/SF
JTotal
2.0 / 2.0 Ft.
LEGAL DESCRIPTION
Depth to pipe invert from original grade
1.5/1.5 Ft.
Gravel depth beneath pipe
0.5/.0.5 Ft.
Subdivision
Block Lot
Lewis and Clark
14
Fill added above original grade
1.5/1.5 Ft.
Gravel length
50 / 50 Ft.
Township Range Section
Gravel width
5/5 Ft.
Beds: Number of Lines
N/A
Distance between lines
N/A Ft.
SEPARATION DISTANCES
To
Septic
Absorption
Lift Station
Holding
Sewer
Total absorption area
Number of trenches
2
Dist. between trenches
From
Tank
Field
Tank
Line
500 Ft2
7.3 Ft.
Well
>100'
>100'
N/A
N/A
>25
TANK ❑ Septic ❑� S.T.E.P. ❑ Holding ❑ Other
Manufacturer
GREER
Capacity
1500 Gal.
Surface Water
>1
>100'
N/A
N/A
Material
STEEL
Number of compartments
2
Lot Line
>5'
>10'
N/A
N/A
NA
Foundation
>10'
>10'
N/A
N/A
LIFT STATION
Manufacturer
G R E E R
Capacity
250 Gal.
Remarks
Alarm location
Mechanical Room
Electrical installed by
Wiring Up AK
PIPE MATERIAL House to tank D3034 drainfield Tank to
D3034
Installer
Red Dog
Drainfield D3034 CO/MT D3034
Inspector L.Tidwell
BENCH MARK (Assumed elevation) 100 ft
Inspection
15' 3/16/22
3/16/22
Location and description
es:
3`" 3/18/22
2�a
4'h 3/22/22
Bottom of siding near FCO
ON-SITE WATER AND WASTEWATER SECTION APPROVAL
Engineer's Stamp
Conditional Approval:
Date
Aor"
An TI•*
....
.'
Septic System
. Benjam�nSchiller /
Approve ', —Z�&Date
/,7-0)
�� �c�G, •, CE 12592 • �`��®
8/31/22
pROFESSIOO�a
Note: this approval does not include well permit requirements.
`l�®
trcev ub/uui u/
O J
O J > m
H
w z W
_I O F -Crf
C7
U1 -w zzw
w Q > J >J
O m cz, o O O U 0
z U M L� LLL. U))
LU
W 800" �> S
i U LL LL 2i�E U I ---
u
Q
-N
c—cq
O�C06J
M
I--:
CV
O �
m
r-
c—
N
N
Cl)
I--
I—
O)
CO
'eY
N
ct'
O�
LO
O
cM
II-
LLQ
t0
N
N
co
U'9
t C�
I`
O
co
O�—Nr-Nco
tet'
!—
PERMIT # OSP211205
103.9
104.4
ENGINEERING
� N
106.9 FINISH GRADE 105.4 ORIGINAL GRADE
�— 2" INSULATION
103.4 103.4
50'
NO GROUNDWATER 6/4/21
.. .
Co 9
107.4 FINISH GRADE 105.9 ORIGINAL GRADE 2i
2" INSULATION
�— 103.9
50'
NO GROUNDWATER 6/4/21
95.4
PROFILE AS -BUILT
(NO SCALE)
103.9
103.9
104.4
49 TH-
.'
..........
' . • • .
Benja 'n Schiller • •' • ,
�`�����lF'•.C8/3122 •'�c,����
���®a�PROf ESSI�NP�"`
PERMIT # OSP211205
ENGINE! RING
PID # 017-074-78
PROFILE AS -BUILT
(NO SCALE)
°Fs°it
49
.M
�. �--...
...
• '' . • "
Benja Schiller ' • '
'o�Fc ••. CE 12592
Development Services Department
Building Safety Division
®n -Site Water & Wastewater Program
MW
4700 Elmore Road
U
P.O. Box 196650 C
MarkBegich Anchorage, AK 99507 s " E i Y
Mayor www.muni.org/onsite
(907) 343-7904
Pump Installation Log
WeH Drilling Permit Number:-Rw(,j7f e?t l 0:7 Date of Issue: -7-
Parcel
Parcel Identification Number:
Legal Description Property Owner Name & Address:
Lew,'; C..I�Yk, L,+ t� 'Fret.; �w� jclew
&I.)Igl
Pump Installation Date: -7 - 0 - 2A
Pump Intake Depth Below Top of Well Casing: ;UG feet
Pump Manufacturer's Name:
Pump Model: `J 5 Q 6 07- -5;U
Pump Size 11q hp
Pitless Adapter Burial Depth: 114- feet
Pitless Adapter Manufacturer's Name: 13' t D �
Pitless Adapter Installer: ted oz- q
Well Disinfected Upon Completion? Yes ❑ No
Method of Disinfection:
%� i?
Comments:
Pump Installer Name: Johnny Kay
Hefty Drilling, Inc.
Attention: The pump installer shall provide a pump installation log to the DSD within 30 days of pump installation.
Development Services Department Phone: 907-343-7904
On -Site Water & Wastewater Section Fax: 907-343-7997
Well Log
Permit Number: #OSP211 Date of Issue: 7/6/20 Parcel Identification Number:
Date Started: 9/13/20 Date Completed: 9/16/20:j� Is well located at approved permit location? Yes ❑■ No ❑
Legal Description: Lewis & Clark Lt: 14 G: 2941
Property Owner Name & Address: Trevi Builders
Borehole Data: Depth (ft)
Soil Type, Thickness & Water Strata From To
Casing Stick Up
0
2
Silt & Gravel w/ Clay Layers
2
60
Wet Silt & Gravel
60
64
Silt & Gravel
64
68
Rock
68
70
Silt & Gravel w/ Clay Layers
70
210
Coarse Gravel w/ H2O
210
215
Coordinates:
N 610 06.000'
W 1490 43.428'
Water Sample Results:
Arsenic:IT— ug/L
Nitrates: m L
Total Coliform Bacteria: colonies/100mL
Method of Drilling ❑■ air rotary ❑ cable tool
Casing type: Steel
Wall Thickness: •250 inches
Diameter: 6 inches Depth: 215 feet
Liner Type:
Diameter: inches Depth: feet
Casing stickup above ground: 2 feet
Static water level (from ground level): 177 feet
Pumping level: feet after
hours pumping _gpm
Recovery Rate: 4.5 gpm
Method of Testing: Airlift
Well Intake Opening Type:
Q Open End ❑ Open Hole
❑ Screened Start feet Stopped feet
❑ Perforations Start feet Stopped feet
vroUL type: tsenionae vorume: -wags
Depth: 20' Start 0 feet Stopped 20 feet
Well Disinfected Upon Completion? Yes No
Method of Disinfection: Tabs Comments:
Well Driller: Johnny Kay ❑ ❑
Company: Hefty Drilling Inc.
Mailing Address: P.O. Box 112130 Anch, AK 9fi
Attention: The well driller shall provide a well log to the
On-site Water and Wastewater Section within 30 days of
completion.
M
O
N
N
3
PIA
LEWIS • FAR' , •' .11
LOT ,•
•
N RQo4n,.in,'F 44A_77'
S 89055'20"E 250.61'
AS -BU
I LT
I HEREBY CERTIFY THAT I HAVE SURVEYED THE
PROPERTY DEPICTED ABOVE AND THAT NO
GASTALDI LAND
ENCROACHMENTS EXIST EXCEPT AS INDICATED.
SURVEYING, LLC
IT IS THE RESPONSIBILITY OF THE OWNER TO
JEFF A. GASTALDI, R.L.S.
DETERMINE THE EXISTENCE OF ANY EASEMENTS,
2000 E. DOWLING RD., SUITE 8
COVENANTS OR RESTRICTIONS WHICH DO NOT
ANCHORAGE, ALASKA 99507
APPS ON THE RECORDED SUBDIVISION PLAT.
PHONE 248-5454
UNDER NO CIRCUMSTANCES SHOULD ANY DATA
GRID
DATE
HEREON BE USED FOR CONSTRUCTION OR FOR
SW2941
1 8/11/2022
ESTABLISHING BOUNDARY OR FENCE LINES.
ANCHORAGE RECORDING DISTRICT, ALASKA
F.B. JOB NO.
22-01 1 LCS14 I NOTE: NO CORNERS SET THIS DATE.
OF4
A
X,P� °° q
AV e so
co 00
° 9
* 49TH
m : Jeffery A. Gastaldi : o
AlF
10, '0' 0 LS -6091 m�jr
8/11/2022 go
A'Ofessional Lata
I
, 1
MUNICIPALITY OF ANCHORAGE
On -Site Water & Wastewater Program
PO Box 196650 4700 Elmore Road
Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997
http://www.muni.org/onsite
On -Site Water & Wastewater System Permit
Permit Number: OSP211205
Work Type: WellSeptic Initial
Tax Code Number: 01707478000
Site Legal Address: LEWIS & CLARK LT 14 G:2941
Site Mailing Address:
Owner: BIG COUNTRY ENTERPRISES LLC
Design Engineer: FORGE ENGINEERING
This permit is for the construction of:
Effective Date:
Expiration Date:
�rcnt
n
v
Delia rrnicn[
Lot Size in Sq Ft:
Total Bedrooms:
7/6/2021
7!612022
86131
0 Disposal Field 0 Septic Tank ❑ Holding Tank ❑ Privy 0 Private Well ❑ Water Storage
Id
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (2417).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
Special Provisions: A test hole is required prior to construction of the absorption field, in location shown on site
plan. Test hole shall confirm minimum separation to impermeables and seasonal high groundwater, as well as
confirm percolation rate. Construction may proceed at your own risk prior to 7 -day groundwater reading. If
results require a design change, construction shall stop pending Onsite review and approval of a change order.
Please submit results with inspection report (or change order, if required).
Veronica Pope
Received By:
Issued By:°
GE
2021.07.06
12:58:44 -08'00'
Date:
Date:
MUNICIPALITY F ANCHORAGE
Community Development Department Phone: 907-343-7904
Development Services Division Fax: 907-343-7997
On -Site Water & Wastewater Program
ON-SITE SEWER/WELL PERMIT APPLICATION
Parcel 1. D. 017-074-78
Property owner(s) Big Country Enterprises Day phone 301-5359
Mailing address 4700 E 147th Avenue, Anchorage, AK, 99516
Site address NHN Trailblaze Circle
Legal description (Sub'd., Block & Lot) Lewis & Clark Sub,
Lot 14
Legal description (Township, Range & Section)
Lot Size 86,131 Sq. Ft. Number of Bedrooms 4
APPLICATION IS FOR: APPLICATION IS AN:
TYPE OF DWELLING:
(® all that apply)
Absorption Field ❑X Initial ❑X
Single Family (SF)
ADU)
Septic Tank MUpgrade El(w/wo
(D) El
Holding Tank ElRenewal ElDuplex
Multiple Dwellings ❑
Privy ❑
(SF and/or D)
Private Well ❑X
Water Storage ❑
THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST
FOR:
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit/Rush Fees: 9,0 Waiver Fees:
Date of Payment: 64zo_ I Date of Payment:
/I
Receipt Number: 626c[ 8 0 Receipt Number:
Permit No. o S P 2 1 1 a o 5 Waiver No.
Permit App__- :: _..:c
June 4, 2021
MOA Development Services, On-Site Water & Wastewater Program
4700 Elmore Rd
Anchorage, AK 99507
6/4/21
Subject: Lewis & Clark Lot 14 – Trailblaze Circle
Septic system design
Dear On-Site Services Engineer:
The owner of the above lot intends to build a 4-bedroom home on the property, so we are
submitting this permit application for the construction of a new well and septic system. The
attached site plan identifies the location of the home as well as the proposed well, septic location
and alternate site. No conflicts exist between this proposed system and any other well or septic
system, whether on this lot or adjacent lots.
The ground surface on the majority of the lot slopes less than 15% southwestwardly. The proposed
septic system will be located near the south property line. There are no slopes greater than 25%
within 50 feet downslope of either the primary or alternate site. Contours are shown on the site
plan showing the grade and direction of flow. Stormwater drainage will not impact this septic
system. The new trench will be constructed parallel to the slope as much as possible.
Wells on this and adjacent lots are shown. The new system will be a minimum of 100’ from all
wells and surface water, and more than 5’ away from the septic tank.
Please refer to the attached test hole logs, plan and profile pages for the septic design. If this design
is followed, there will be no adverse impacts to adjacent properties.
Sincerely,
Benjamin Schiller, PE
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP211205, Rebecca Carroll, 07/06/21
NOTE:
NO SLOPES >25% ARE WITHIN 50' OF THE PROPOSED SEPTIC SYSTEM. NO SURFACE WATER WITHIN 100' OF
THE SEPTIC SYSTEM.
ALL WELLS ON SURROUNDING LOTS WITH IMPACTS TO THIS PROPERTY ARE SHOWN. NO CONFLICTS WITH
WELLS OR SEPTIC SYSTEMS.
CO - CLEANOUT
2CO - DOUBLE CLEANOUT
FCO - FOUNDATION CLEANOUT
FD - FLOW DIVERTER VALVE
MH - MANHOLE
MT - MONITORING TUBE
SV - SEPTIC VENT
TH - TEST HOLE
LEGEND
1"=50'4-BDRM HOMELEWIS & CLARK SUB, LOT 14
FEET
0 50 100
7/6/21
10' T&E EASEMENT
TH#2
PROPOSED WELL
2 - 50' LONG x 5' WIDE x 0.5' EFFECTIVE
DEPTH ABSORPTION TRENCHES
MAINTAIN 6' SEPARATION BETWEEN
SIDE WALLS
ALTERNATE SITE
1065
1055
1045
1,500 GALLON
STEP TANK
MAINTAIN 10' MIN
FROM FOUNDATION FCOMT
MT
MT
MT
100' WELL RADII
PROPOSED TEST HOLE
TO BE DONE PRIOR TO
CONSTRUCTION
TH#1
NOTE:
TANK MAY REQUIRE BALLASTING DUE TO HIGH
GROUNDWATER. CONTACT IF BALLASTING IS REQUIRED.
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP211205, Rebecca Carroll, 07/06/21
LEWIS & CLARK SUB, LOT 14
TYPICAL TRENCH SECTION
(NO SCALE)
NOTES:
1. GRADE AREA OVER TRENCH TO DRAIN AWAY
2. PROVIDE 3' OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2'
WITH 2" OF INSULATION
3. CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER
THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY
1 1
4" PVC w/ 15 - 3
16" HOLES PER
LATERAL SPACED EVENLY
(HOLES DOWN)
DRAINFIELD ROCK
5'
6"
1'
1'
6"
DESIGN FACTORS:SYSTEM REQUIREMENTS:
600 GPD PEAK FLOW
PERK RATE: 1.8 MIN/IN
APPLICATION RATE: 1.2 GPD/SF
SHALLOW TRENCH SYSTEM
1500-GAL STEP TANK
BOTTOM OF TRENCH: 2' BELOW GRADE
FLOW LINE ELEVATION: 1' 6" BELOW GRADE
TOP OF TRENCH: 6" ABOVE GRADE
600 GPD / 1.2 GPD/SF /5' WIDE * 1.0 RED FACTOR = 100 LF TRENCH REQUIRED (100 LF SPECIFIED)
6/3/21
2" INSULATION
ORIGINAL GRADE
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP211205, Rebecca Carroll, 07/06/21
LEGAL DESCRIPTION:
PERFORMED FOR:
DATE:
PARCEL ID#:
SOILS LOG AND PERCOLATION TEST
TECHNICIAN:
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
DEPTH
(feet)
PROJECT No.:
TEST HOLE 1
SLOPE
SLOPE
SITE PLAN
DATE READING GROSS TIME
(minutes)
NET TIME
(minutes)
DEPTH to
WATER NET DROP
PERC. HOLE DIA. (INCHES)PERCOLATION RATE: (MIN/INCH)
TEST RUN BETWEEN: FT. and FT.
COMMENTS:
(inches)(inches)
J. Millette
DATE OF MONITORING:
WAS GROUND WATER ENCOUNTERED?
DEPTH TO WATER AFTER MONITORING:
IF YES @ WHAT DEPTH?6'
1.8 6
3 4
5/14
1
2
3
4
5
6
GM (SILTY SANDY GRAVEL)
Professional Engineers Stamp:
YES
nONE
6/4/21
Lewis & Clark Lot 14
5/14/21
017-074-78
Eric Trevitlick
14:351
2
3
4
5
6
0 - 6
14:42
14:53
15:04
15:15
15:26
OB
6:16 6
0 - 68:30 6
0 - 5 8
1610 5 8
16
0 - 5 8
1610 5 8
16
0 - 5 8
1610 5 8
16
0 - 5 8
1610 5 8
16
6/4/21
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP211205, Rebecca Carroll, 07/06/21
LEGAL DESCRIPTION:
PERFORMED FOR:
DATE:
PARCEL ID#:
SOILS LOG AND PERCOLATION TEST
TECHNICIAN:
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
DEPTH
(feet)
PROJECT No.:
TEST HOLE 2
SLOPE
SLOPE
SITE PLAN
DATE READING GROSS TIME
(minutes)
NET TIME
(minutes)
DEPTH to
WATER NET DROP
PERC. HOLE DIA. (INCHES)PERCOLATION RATE: (MIN/INCH)
TEST RUN BETWEEN: FT. and FT.
COMMENTS:
(inches)(inches)
J. Millette
DATE OF MONITORING:
WAS GROUND WATER ENCOUNTERED?
DEPTH TO WATER AFTER MONITORING:
IF YES @ WHAT DEPTH?6.5'
3.1 6
3 4
5/14
1
2
3
4
5
6
GM (SILTY SANDY GRAVEL)
Professional Engineers Stamp:
YES
7.0'
6/4/21
Lewis & Clark Lot 14
5/14/21
017-074-78
Eric Trevitlick
16:011
2
3
4
5
6
OB
10
16:13 10
16:25 10
16:36 10
16:48 10
16:59 3 8
16 / 6 12
1610 3 4
16
3 8
16 / 6 12
16 3 4
16
3 8
16 / 6 12
16 3 4
16
3 8
16 / 6 14
16 3 6
16
3 8
16 / 7 0
16 3 8
16
3 8
16 / 7 7
16 3 1
16
6/4/21
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP211205, Rebecca Carroll, 07/06/21