Loading...
HomeMy WebLinkAboutLEWIS & CLARK LT 14Onsite File Lewis & Clark Lot 14 #017-074-78 trcev ub/uui u/ Municipality of Anchorage On-Site Water and Wastewater Section • (907) 343-7904 Page 1 of 3 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP211205 PID Number: 017-074-78 Dwelling: ❑■ Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: ■❑ New ❑ Upgrade Name Big Country Enterprises ABSORPTION FIELD ❑ Deep Trench N] Wide Trench ❑ Bed ❑ Mound Site Address NHN Trailblaze Cir, Anchorage, AK 99516 ❑ Other Phone Number of Bedrooms Soil Rating depth from original grade 907-301-5359 4 1.2 GPD/SF JTotal 2.0 / 2.0 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade 1.5/1.5 Ft. Gravel depth beneath pipe 0.5/.0.5 Ft. Subdivision Block Lot Lewis and Clark 14 Fill added above original grade 1.5/1.5 Ft. Gravel length 50 / 50 Ft. Township Range Section Gravel width 5/5 Ft. Beds: Number of Lines N/A Distance between lines N/A Ft. SEPARATION DISTANCES To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches 2 Dist. between trenches From Tank Field Tank Line 500 Ft2 7.3 Ft. Well >100' >100' N/A N/A >25 TANK ❑ Septic ❑� S.T.E.P. ❑ Holding ❑ Other Manufacturer GREER Capacity 1500 Gal. Surface Water >1 >100' N/A N/A Material STEEL Number of compartments 2 Lot Line >5' >10' N/A N/A NA Foundation >10' >10' N/A N/A LIFT STATION Manufacturer G R E E R Capacity 250 Gal. Remarks Alarm location Mechanical Room Electrical installed by Wiring Up AK PIPE MATERIAL House to tank D3034 drainfield Tank to D3034 Installer Red Dog Drainfield D3034 CO/MT D3034 Inspector L.Tidwell BENCH MARK (Assumed elevation) 100 ft Inspection 15' 3/16/22 3/16/22 Location and description es: 3`" 3/18/22 2�a 4'h 3/22/22 Bottom of siding near FCO ON-SITE WATER AND WASTEWATER SECTION APPROVAL Engineer's Stamp Conditional Approval: Date Aor" An TI­•* .... .' Septic System . Benjam�nSchiller / Approve ', —Z�&Date /,7-0) �� �c�G, •, CE 12592 • �`��® 8/31/22 pROFESSIOO�a Note: this approval does not include well permit requirements. `l�® trcev ub/uui u/ O J O J > m H w z W _I O F -Crf C7 U1 -w zzw w Q > J >J O m cz, o O O U 0 z U M L� LLL. U)) LU W 800" �> S i U LL LL 2i�E U I --- u Q -N c—cq O�C06J M I--: CV O � m r- c— N N Cl) I-- I— O) CO 'eY N ct' O� LO O cM II- LLQ t0 N N co U'9 t C� I` O co O�—Nr-Nco tet' !— PERMIT # OSP211205 103.9 104.4 ENGINEERING � N 106.9 FINISH GRADE 105.4 ORIGINAL GRADE �— 2" INSULATION 103.4 103.4 50' NO GROUNDWATER 6/4/21 .. . Co 9 107.4 FINISH GRADE 105.9 ORIGINAL GRADE 2i 2" INSULATION �— 103.9 50' NO GROUNDWATER 6/4/21 95.4 PROFILE AS -BUILT (NO SCALE) 103.9 103.9 104.4 49 TH- .' .......... ' . • • . Benja 'n Schiller • •' • , �`�����lF'•.C8/3122 •'�c,���� ���®a�PROf ESSI�NP�"` PERMIT # OSP211205 ENGINE! RING PID # 017-074-78 PROFILE AS -BUILT (NO SCALE) °Fs°it 49 .M �. �--... ... • '' . • " Benja Schiller ' • ' 'o�Fc ••. CE 12592 Development Services Department Building Safety Division ®n -Site Water & Wastewater Program MW 4700 Elmore Road U P.O. Box 196650 C MarkBegich Anchorage, AK 99507 s " E i Y Mayor www.muni.org/onsite (907) 343-7904 Pump Installation Log WeH Drilling Permit Number:-Rw(,j7f e?t l 0:7 Date of Issue: -7- Parcel Parcel Identification Number: Legal Description Property Owner Name & Address: Lew,'; C..I�Yk, L,+ t� 'Fret.; �w� jclew &I.)Igl Pump Installation Date: -7 - 0 - 2A Pump Intake Depth Below Top of Well Casing: ;UG feet Pump Manufacturer's Name: Pump Model: `J 5 Q 6 07- -5;U Pump Size 11q hp Pitless Adapter Burial Depth: 114- feet Pitless Adapter Manufacturer's Name: 13' t D � Pitless Adapter Installer: ted oz- q Well Disinfected Upon Completion? Yes ❑ No Method of Disinfection: %� i? Comments: Pump Installer Name: Johnny Kay Hefty Drilling, Inc. Attention: The pump installer shall provide a pump installation log to the DSD within 30 days of pump installation. Development Services Department Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Well Log Permit Number: #OSP211 Date of Issue: 7/6/20 Parcel Identification Number: Date Started: 9/13/20 Date Completed: 9/16/20:j� Is well located at approved permit location? Yes ❑■ No ❑ Legal Description: Lewis & Clark Lt: 14 G: 2941 Property Owner Name & Address: Trevi Builders Borehole Data: Depth (ft) Soil Type, Thickness & Water Strata From To Casing Stick Up 0 2 Silt & Gravel w/ Clay Layers 2 60 Wet Silt & Gravel 60 64 Silt & Gravel 64 68 Rock 68 70 Silt & Gravel w/ Clay Layers 70 210 Coarse Gravel w/ H2O 210 215 Coordinates: N 610 06.000' W 1490 43.428' Water Sample Results: Arsenic:IT— ug/L Nitrates: m L Total Coliform Bacteria: colonies/100mL Method of Drilling ❑■ air rotary ❑ cable tool Casing type: Steel Wall Thickness: •250 inches Diameter: 6 inches Depth: 215 feet Liner Type: Diameter: inches Depth: feet Casing stickup above ground: 2 feet Static water level (from ground level): 177 feet Pumping level: feet after hours pumping _gpm Recovery Rate: 4.5 gpm Method of Testing: Airlift Well Intake Opening Type: Q Open End ❑ Open Hole ❑ Screened Start feet Stopped feet ❑ Perforations Start feet Stopped feet vroUL type: tsenionae vorume: -wags Depth: 20' Start 0 feet Stopped 20 feet Well Disinfected Upon Completion? Yes No Method of Disinfection: Tabs Comments: Well Driller: Johnny Kay ❑ ❑ Company: Hefty Drilling Inc. Mailing Address: P.O. Box 112130 Anch, AK 9fi Attention: The well driller shall provide a well log to the On-site Water and Wastewater Section within 30 days of completion. M O N N 3 PIA LEWIS • FAR' , •' .11 LOT ,• • N RQo4n,.in,'F 44A_77' S 89055'20"E 250.61' AS -BU I LT I HEREBY CERTIFY THAT I HAVE SURVEYED THE PROPERTY DEPICTED ABOVE AND THAT NO GASTALDI LAND ENCROACHMENTS EXIST EXCEPT AS INDICATED. SURVEYING, LLC IT IS THE RESPONSIBILITY OF THE OWNER TO JEFF A. GASTALDI, R.L.S. DETERMINE THE EXISTENCE OF ANY EASEMENTS, 2000 E. DOWLING RD., SUITE 8 COVENANTS OR RESTRICTIONS WHICH DO NOT ANCHORAGE, ALASKA 99507 APPS ON THE RECORDED SUBDIVISION PLAT. PHONE 248-5454 UNDER NO CIRCUMSTANCES SHOULD ANY DATA GRID DATE HEREON BE USED FOR CONSTRUCTION OR FOR SW2941 1 8/11/2022 ESTABLISHING BOUNDARY OR FENCE LINES. ANCHORAGE RECORDING DISTRICT, ALASKA F.B. JOB NO. 22-01 1 LCS14 I NOTE: NO CORNERS SET THIS DATE. OF4 A X,P� °° q AV e so co 00 ° 9 * 49TH m : Jeffery A. Gastaldi : o AlF 10, '0' 0 LS -6091 m�jr 8/11/2022 go A'Ofessional Lata I , 1 MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Water & Wastewater System Permit Permit Number: OSP211205 Work Type: WellSeptic Initial Tax Code Number: 01707478000 Site Legal Address: LEWIS & CLARK LT 14 G:2941 Site Mailing Address: Owner: BIG COUNTRY ENTERPRISES LLC Design Engineer: FORGE ENGINEERING This permit is for the construction of: Effective Date: Expiration Date: �rcnt n v Delia rrnicn[ Lot Size in Sq Ft: Total Bedrooms: 7/6/2021 7!612022 86131 0 Disposal Field 0 Septic Tank ❑ Holding Tank ❑ Privy 0 Private Well ❑ Water Storage Id All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (2417). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Special Provisions: A test hole is required prior to construction of the absorption field, in location shown on site plan. Test hole shall confirm minimum separation to impermeables and seasonal high groundwater, as well as confirm percolation rate. Construction may proceed at your own risk prior to 7 -day groundwater reading. If results require a design change, construction shall stop pending Onsite review and approval of a change order. Please submit results with inspection report (or change order, if required). Veronica Pope Received By: Issued By:° GE 2021.07.06 12:58:44 -08'00' Date: Date: MUNICIPALITY F ANCHORAGE Community Development Department Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On -Site Water & Wastewater Program ON-SITE SEWER/WELL PERMIT APPLICATION Parcel 1. D. 017-074-78 Property owner(s) Big Country Enterprises Day phone 301-5359 Mailing address 4700 E 147th Avenue, Anchorage, AK, 99516 Site address NHN Trailblaze Circle Legal description (Sub'd., Block & Lot) Lewis & Clark Sub, Lot 14 Legal description (Township, Range & Section) Lot Size 86,131 Sq. Ft. Number of Bedrooms 4 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (® all that apply) Absorption Field ❑X Initial ❑X Single Family (SF) ADU) Septic Tank MUpgrade El(w/wo (D) El Holding Tank ElRenewal ElDuplex Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑X Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: 9,0 Waiver Fees: Date of Payment: 64zo_ I Date of Payment: /I Receipt Number: 626c[ 8 0 Receipt Number: Permit No. o S P 2 1 1 a o 5 Waiver No. Permit App__- :: _..:c June 4, 2021 MOA Development Services, On-Site Water & Wastewater Program 4700 Elmore Rd Anchorage, AK 99507 6/4/21 Subject: Lewis & Clark Lot 14 – Trailblaze Circle Septic system design Dear On-Site Services Engineer: The owner of the above lot intends to build a 4-bedroom home on the property, so we are submitting this permit application for the construction of a new well and septic system. The attached site plan identifies the location of the home as well as the proposed well, septic location and alternate site. No conflicts exist between this proposed system and any other well or septic system, whether on this lot or adjacent lots. The ground surface on the majority of the lot slopes less than 15% southwestwardly. The proposed septic system will be located near the south property line. There are no slopes greater than 25% within 50 feet downslope of either the primary or alternate site. Contours are shown on the site plan showing the grade and direction of flow. Stormwater drainage will not impact this septic system. The new trench will be constructed parallel to the slope as much as possible. Wells on this and adjacent lots are shown. The new system will be a minimum of 100’ from all wells and surface water, and more than 5’ away from the septic tank. Please refer to the attached test hole logs, plan and profile pages for the septic design. If this design is followed, there will be no adverse impacts to adjacent properties. Sincerely, Benjamin Schiller, PE Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP211205, Rebecca Carroll, 07/06/21 NOTE: NO SLOPES >25% ARE WITHIN 50' OF THE PROPOSED SEPTIC SYSTEM. NO SURFACE WATER WITHIN 100' OF THE SEPTIC SYSTEM. ALL WELLS ON SURROUNDING LOTS WITH IMPACTS TO THIS PROPERTY ARE SHOWN. NO CONFLICTS WITH WELLS OR SEPTIC SYSTEMS. CO - CLEANOUT 2CO - DOUBLE CLEANOUT FCO - FOUNDATION CLEANOUT FD - FLOW DIVERTER VALVE MH - MANHOLE MT - MONITORING TUBE SV - SEPTIC VENT TH - TEST HOLE LEGEND 1"=50'4-BDRM HOMELEWIS & CLARK SUB, LOT 14 FEET 0 50 100 7/6/21 10' T&E EASEMENT TH#2 PROPOSED WELL 2 - 50' LONG x 5' WIDE x 0.5' EFFECTIVE DEPTH ABSORPTION TRENCHES MAINTAIN 6' SEPARATION BETWEEN SIDE WALLS ALTERNATE SITE 1065 1055 1045 1,500 GALLON STEP TANK MAINTAIN 10' MIN FROM FOUNDATION FCOMT MT MT MT 100' WELL RADII PROPOSED TEST HOLE TO BE DONE PRIOR TO CONSTRUCTION TH#1 NOTE: TANK MAY REQUIRE BALLASTING DUE TO HIGH GROUNDWATER. CONTACT IF BALLASTING IS REQUIRED. Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP211205, Rebecca Carroll, 07/06/21 LEWIS & CLARK SUB, LOT 14 TYPICAL TRENCH SECTION (NO SCALE) NOTES: 1. GRADE AREA OVER TRENCH TO DRAIN AWAY 2. PROVIDE 3' OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2' WITH 2" OF INSULATION 3. CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY 1 1 4" PVC w/ 15 - 3 16" HOLES PER LATERAL SPACED EVENLY (HOLES DOWN) DRAINFIELD ROCK 5' 6" 1' 1' 6" DESIGN FACTORS:SYSTEM REQUIREMENTS: 600 GPD PEAK FLOW PERK RATE: 1.8 MIN/IN APPLICATION RATE: 1.2 GPD/SF SHALLOW TRENCH SYSTEM 1500-GAL STEP TANK BOTTOM OF TRENCH: 2' BELOW GRADE FLOW LINE ELEVATION: 1' 6" BELOW GRADE TOP OF TRENCH: 6" ABOVE GRADE 600 GPD / 1.2 GPD/SF /5' WIDE * 1.0 RED FACTOR = 100 LF TRENCH REQUIRED (100 LF SPECIFIED) 6/3/21 2" INSULATION ORIGINAL GRADE Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP211205, Rebecca Carroll, 07/06/21 LEGAL DESCRIPTION: PERFORMED FOR: DATE: PARCEL ID#: SOILS LOG AND PERCOLATION TEST TECHNICIAN: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 DEPTH (feet) PROJECT No.: TEST HOLE 1 SLOPE SLOPE SITE PLAN DATE READING GROSS TIME (minutes) NET TIME (minutes) DEPTH to WATER NET DROP PERC. HOLE DIA. (INCHES)PERCOLATION RATE: (MIN/INCH) TEST RUN BETWEEN: FT. and FT. COMMENTS: (inches)(inches) J. Millette DATE OF MONITORING: WAS GROUND WATER ENCOUNTERED? DEPTH TO WATER AFTER MONITORING: IF YES @ WHAT DEPTH?6' 1.8 6 3 4 5/14 1 2 3 4 5 6 GM (SILTY SANDY GRAVEL) Professional Engineers Stamp: YES nONE 6/4/21 Lewis & Clark Lot 14 5/14/21 017-074-78 Eric Trevitlick 14:351 2 3 4 5 6 0 - 6 14:42 14:53 15:04 15:15 15:26 OB 6:16 6 0 - 68:30 6 0 - 5 8 1610 5 8 16 0 - 5 8 1610 5 8 16 0 - 5 8 1610 5 8 16 0 - 5 8 1610 5 8 16 6/4/21 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP211205, Rebecca Carroll, 07/06/21 LEGAL DESCRIPTION: PERFORMED FOR: DATE: PARCEL ID#: SOILS LOG AND PERCOLATION TEST TECHNICIAN: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 DEPTH (feet) PROJECT No.: TEST HOLE 2 SLOPE SLOPE SITE PLAN DATE READING GROSS TIME (minutes) NET TIME (minutes) DEPTH to WATER NET DROP PERC. HOLE DIA. (INCHES)PERCOLATION RATE: (MIN/INCH) TEST RUN BETWEEN: FT. and FT. COMMENTS: (inches)(inches) J. Millette DATE OF MONITORING: WAS GROUND WATER ENCOUNTERED? DEPTH TO WATER AFTER MONITORING: IF YES @ WHAT DEPTH?6.5' 3.1 6 3 4 5/14 1 2 3 4 5 6 GM (SILTY SANDY GRAVEL) Professional Engineers Stamp: YES 7.0' 6/4/21 Lewis & Clark Lot 14 5/14/21 017-074-78 Eric Trevitlick 16:011 2 3 4 5 6 OB 10 16:13 10 16:25 10 16:36 10 16:48 10 16:59 3 8 16 / 6 12 1610 3 4 16 3 8 16 / 6 12 16 3 4 16 3 8 16 / 6 12 16 3 4 16 3 8 16 / 6 14 16 3 6 16 3 8 16 / 7 0 16 3 8 16 3 8 16 / 7 7 16 3 1 16 6/4/21 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP211205, Rebecca Carroll, 07/06/21