Loading...
HomeMy WebLinkAboutT12N R3W SEC 15 LT 7Onsite File 7:i.Fom Fi$ .,.234tF t`._� .�y a•'7i. a; h.> �w � ��4 -:dr^t :s"= `"-`M'^m.,a,'xi*-�. k MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Water & Wastewater System Permit Permit Number: OSP211375 Work Type: WellSeptic Initial Tax Code Number: 01550108000 Site Legal Address: T1 2N R3W SEC 15 LT 7 G:2537 Site Mailing Address: 5140 E 104TH AVE, Anchorage Owner: STARCK KAI & JENNIFER Design Engineer: FORGE ENGINEERING This permit is for the construction of: Q Disposal Field Q Septic Tank Holding Tank Privy Effective Date Expiration Date Lot Size in Sq Ft: Total Bedrooms: 11 t O Department 9/8/2021 9/8/2022 206744 Q Private Well Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Received By: / Issued By: Date: Date: g Z El MUNICIPALITY OF ANCHORAGE Community Development Department Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On -Site Water & Wastewater Program ON-SITE SEWER/WELL PERMIT APPLICATION Parcel 1. D. 015-501-08 Property owner(s) Kai & Jennifer Starck Day phone 301-5359 Mailing address PO Box 240201, Anchorage, AK 99524 S;t dd 5140 E 104th Ave Legal description (Sub'd., Block & Lot) Legal description (Township, Range & Section) T1 2N R3W SEC 15, Lot 7 Lot Size 206,744 Sq. Ft. Number of Bedrooms 4 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (N all that apply) Absorption Field ❑x Initial ❑ Single Family (SF) (w/wo ADU) Septic Tank MUpgrade ❑X Duplex (D) Holding Tank ElRenewal ❑ Multiple Dwellings Privy ❑ (SF and/or D) Private Well ❑x Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: �P�rj2� Waiver Fees: Date of Payment: I i 12 Date of Payment: Receipt Number: of 5 `(3 Receipt Number: Permit No. n P2 1137-5 Waiver No. Permit App__- ..:c ❑x September 7, 2021 MOA Development Services, On-Site Water & Wastewater Program 4700 Elmore Rd Anchorage, AK 99507 9/7/21 Subject: T12N R3W SEC15, Lot 7 – E 104th Ave Septic system design Dear On-Site Services Engineer: The owner of the above lot intends to build a 4-bedroom home on the property, so we are submitting this permit application for the construction of a new well and septic system. There is an existing cabin on the property with no well or septic system that will be demolished. The attached site plan identifies the location of the home as well as the proposed well, septic location and alternate site. No conflicts exist between this proposed system and any other well or septic system, whether on this lot or adjacent lots. The majority of the ground surface on the lot slopes toward the southwest at less than 10%. There are no slopes greater than 25% within 50 feet downslope of either the primary or alternate site. Contours are shown on the site plan showing the grade and direction of flow. Stormwater drainage will not impact this septic system. The new trench will be constructed parallel to the slope as much as possible. Wells on this and adjacent lots are shown. The new system will be a minimum of 100’ from all wells and surface water, and more than 5’ away from the septic tank. The alternate site is located more than 6’ away. Please refer to the attached test hole logs, plan and profile pages for the septic design. If this design is followed, there will be no adverse impacts to adjacent properties. Sincerely, Michael E. Anderson, PE Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP211375, Deb Wockenfuss, 09/08/21 1"=100' CO - CLEANOUT 2CO - DOUBLE CLEANOUT FCO - FOUNDATION CLEANOUT FS - FLOW SPLITTER VALVE MH - MANHOLE MT - MONITORING TUBE SV - SEPTIC VENT TH - TEST HOLE LEGENDTH# 1 T12N R3W SEC15 LOT 7 FEET 0 100 200 NOTE: NO SLOPES >25% WITHIN 50' OR SURFACE WATER WITHIN 100' OF THE PROPOSED SEPTIC SYSTEM ALL WELLS ON SURROUNDING LOTS WITH IMPACTS TO THIS PROPERTY ARE SHOWN. NO CONFLICTS WITH WELLS OR SEPTIC SYSTEMS. EAST 104th AVENUE 4-BDR M H O M E August 30, 2021 33' BLM RESERVATION 100' STREAM SETBACK CLASS A WETLANDS BOUNDARY LITTLE CAMPBELL CREEK (APPX PER MOA MAPPING) TH#2 PRIMARY & ALTERNATE SITES PROPOSED WELL EXISTING WELL EXISTING WELL Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP211375, Deb Wockenfuss, 09/08/21 1"=50' CO - CLEANOUT 2CO - DOUBLE CLEANOUT FCO - FOUNDATION CLEANOUT FS - FLOW SPLITTER VALVE MH - MANHOLE MT - MONITORING TUBE SV - SEPTIC VENT TH - TEST HOLE LEGEND T12N R3W SEC15 LOT 7 FEET 0 50 100 ≥6' NOTE: NO SLOPES >25% WITHIN 50' OR SURFACE WATER WITHIN 100' OF THE PROPOSED SEPTIC SYSTEM ALL WELLS ON SURROUNDING LOTS WITH IMPACTS TO THIS PROPERTY ARE SHOWN. NO CONFLICTS WITH WELLS OR SEPTIC SYSTEMS. 4-BDR M HO M E September 7, 2021 100' STREAM SETBACK CLASS A WETLANDS BOUNDARY LITTLE CAMPBELL CREEK (APPX PER MOA MAPPING) TH#2 PROPOSED WELL TH#1 100' WELL RADIUS ALTERNATE SITE 2 - 60' LONG x 5' WIDE, 0.5' EFFECTIVE DEPTH ABSORPTION TRENCHES MAINTAIN 6' MIN SEPARATION CO CO CO CO FCO MT MT MT MT FS2CO1250-GAL SEPTIC TANK w/ 20" MANWAY MAINTAIN 10' FROM FOUNDATION 455 450 445 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP211375, Deb Wockenfuss, 09/08/21 T12N R3W SEC15 LOT 7 TYPICAL TRENCH SECTION (NO SCALE) NOTES: 1. GRADE AREA OVER TRENCH TO DRAIN AWAY 2. PROVIDE 3' OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2' WITH 2" OF INSULATION 3. CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY 4" PERFORATED PVC (HOLES DOWN) DRAINFIELD ROCK 5' 6" 6" 4' 2' DESIGN FACTORS:SYSTEM REQUIREMENTS: 600 GPD PEAK FLOW PERK RATE: <1 MIN/IN APPLICATION RATE: 1.0 GPD/SF SHALLOW TRENCH SYSTEM w/ SAND LINER 1,250-GAL SEPTIC TANK w/ 20" MANWAY BOTTOM OF TRENCH: 5' BELOW GRADE FLOW LINE ELEVATION: 4' 6" BELOW GRADE TOP OF TRENCH: 6"' ABOVE GRADE 600 GPD / 1.0 GPD/SF / 5' WIDE *-1.0 RED FACTOR = 120 LF TRENCH REQUIRED (120 LF SPECIFIED) August 30, 2021 6" MOA APPROVED FILTER SAND Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP211375, Deb Wockenfuss, 09/08/21 LEGAL DESCRIPTION: PERFORMED FOR: DATE: PARCEL ID#: SOILS LOG AND PERCOLATION TEST TECHNICIAN: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 DEPTH (feet) PROJECT No.: TH-1 (WEST) SLOPE SLOPE SITE PLAN DATE READING GROSS TIME (minutes) NET TIME (minutes) DEPTH to WATER NET DROP PERC. HOLE DIA. (INCHES)PERCOLATION RATE: (MIN/INCH) TEST RUN BETWEEN: FT. and FT. COMMENTS: (inches)(inches) J. Millette DATE OF MONITORING: WAS GROUND WATER ENCOUNTERED? DEPTH TO WATER AFTER MONITORING: IF YES @ WHAT DEPTH?- <1 6 3 4 7/27 1 2 3 4 5 6 GP (POORLY GRADED SANDY GRAVEL) Professional Engineers Stamp: NO DRY 8/5/21 T12N R3W Sec15 L7 7/27/21 015-501-08 Eric Trevithick 11:20 1 2 3 4 5 6 0 - 6 1' OB <30 sec August 30, 2021 SANDY LOAM SP (POORLY GRADED SAND,COARSE) BOH 6 11:21 0 - 6<30 sec 6 11:22 0 - 6<30 sec 6 11:23 0 - 6<30 sec 6 11:24 0 - 6<30 sec 6 11:25 0 - 6<30 sec 6 "SP" is same material as "GP" but with absence of cobbles. Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP211375, Deb Wockenfuss, 09/08/21 LEGAL DESCRIPTION: PERFORMED FOR: DATE: PARCEL ID#: SOILS LOG AND PERCOLATION TEST TECHNICIAN: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 DEPTH (feet) PROJECT No.: TH-2 (EAST) SLOPE SLOPE SITE PLAN DATE READING GROSS TIME (minutes) NET TIME (minutes) DEPTH to WATER NET DROP PERC. HOLE DIA. (INCHES)PERCOLATION RATE: (MIN/INCH) TEST RUN BETWEEN: FT. and FT. COMMENTS: (inches)(inches) J. Millette DATE OF MONITORING: WAS GROUND WATER ENCOUNTERED? DEPTH TO WATER AFTER MONITORING: IF YES @ WHAT DEPTH?- <1 6 3 4 7/27 1 2 3 4 5 6 GP (POORLY GRADED SANDY GRAVEL) Professional Engineers Stamp: NO DRY 8/5/21 T12N R3W Sec15 L7 7/27/21 015-501-08 Eric Trevithick 11:38 1 2 3 4 5 6 0 - 6 1' OB <30 sec August 30, 2021 SANDY LOAM BOH 6 11:39 0 - 6<30 sec 6 11:40 0 - 6<30 sec 6 11:41 0 - 6<30 sec 6 11:42 0 - 6<30 sec 6 11:43 0 - 6<30 sec 6 Unable to dig deeper safely due to excess sloughing. Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP211375, Deb Wockenfuss, 09/08/21