Loading...
HomeMy WebLinkAboutPALATERRA ADDN 2 LT 9Onsite File Palaterra Addn 2 Lot 9 PID# 017-151-33 Formerly Palaterra Block 2A nnU ality of Anchorage _ I)r.�rrlmenr j P.O. Box 196650 ® 4700 Elmore Road Anchorage, Alaska 99519-6650 ®(907) 343-7904 • Fax (907) 343-7997 http://www.muni.org/Onsite Development Services Division On-Site Water and Wastewater Program * * * * VARIANCE/WAIVER REVIEW * * * * Waiver#: OSV241012 COSA#: Permit#:OSP231084 PID#: 017-151-34 Legal Description: PALATERRA ADDN 2 LT 10 Engineer: Forge engineerinq Your request for a waiver of the required 100 feet horizontal separation from the absorption field and septic tank on Lot 9 to the private well on Lot 10 has been approved. The approved separation distance is 91.0 feet for the field and 88' for the tank. This waiver approval applies to the existing absorption field and septic tank only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. ............................................... ■ ............................. ■ 1 Waiver is Granted: X Waiver is not Granted: Ar L1 /y /Z Li Named vier ............................................................................ 1 **** VARIAN C E/WAIVER REVIEW **** Municipality of Anchorage On -Site Water and Wastewater Section • (907) 343-7904 Page 1 of 3 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP211401 PID Number: 017-151-22 Dwelling: A Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: 9 New ❑ Upgrade Name COLONY BUILDERS ABSORPTION FIELD 9 Deep Trench ❑ Wide Trench ❑ Bed ❑ Mound Site Address 13400 DEPALATIS CIR, ANCHORAGE, AK 99516 ❑ Other Phone 907-345-0371 Number of Bedrooms 5 Soil Rating Total depth from original grade 0.8 GPD/SF 12.0 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade 4.0 Ft. Gravel depth beneath pipe 8.0 Ft. Subdivision Block Lot PALATERRA ADDN. #2 9 Fill added above original grade 2.6 Gravel length 60.0 Township Range Section Ft. Ft. Gravel width 3 Ft. Beds: Number of Lines N/A Distance between lines N/A Ft. SEPARATION DISTANCES To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Tank Line 960 Ftz 1 N/A Ft. Well >100' >100' N/A N/A >25 TANK F21 Septic ❑ S.T.E.P. ❑ Holding ❑ Other Manufacturer_ GREER _Capacity 1500 Gal. Surface Water >100' >100' N/A N/A Material PLASTIC Number of compartments 2 Lot Line >5' >10' N/A N/A NA Foundation >1 0' >10' N/A N/A LIET STATION Manufac Capacity Remarks Gal. Alarm location Elec nstalled by Installer PIPE MATERIAL House to tank D3034. Tank to D3034 drainfield Bronson Brother LLC Drainfield D3034 CO/MT D3034 Inspector L.Tidwell/ J.Millette BENCH MARK (Assumed elevation) 100 ft Inspection151 11/17/21 11/19/21 Location and description 2�d 3rd 11/19/23 41111/19/26 TOP OF FOUNDATION AT SW CORNER OF HOUSE ON-SITE WATER AND WASTEWATER SECTION APPROVAL Engineer's Stamp Conditional Approval: o Date ���'c ®r-`����: co r� ..�'....�...;. :.. ' ... . �� . Septic System Benjam,� Schiller ¢� �F� • Approve CE 12592 Date Z� 2Z ��'srF9• s/2o/2? ��� PROFESSIONPa Note: this does approval not include well permit requirements. 10.,.. nunni4 0% �oWoo� —01 � SPANISH HI�LS ��•�mv I� •O� I Ah ++1lyFFR A/ r / m m m / m r T� O m W o CO s� O T 0 m Gp n �/1 O o W cn %// mo o N CD / / / Z M m // ��X O Z N I( 0 oi ,, I / ocn cn I i / \ o� O C N�:o o J / zo D D / C) 0� �2� o O o T 2 Q / mI I J r Icn TOO m... mm��mTp� = O O D p — GOOrp y ozzmm��o r �/ C � C7 Z m G m O m o �/� DEPALATIS �/ C�� N ON O O < ? O m —I —I —I —I fV W O N W W A A ,�C.0oow�, -.4O) -P, cn cn C N --I T 2 Q / mI I J r Icn TOO m... mm��mTp� = O O D p — GOOrp y ozzmm��o r �/ C � C7 Z m G m O m o �/� DEPALATIS �/ PROFILE AS-BUILT (NO SCALE) 91.4 85.5 91.8 97.02CO1MH1 SV11500 GAL SEPTIC TANK 97.6 FINISH GRADE 60'MT1P9 NGENO GROUNDWATER 6/25/21 83.1 91.0 CO1CO276.0 83.0 91.0 95.0 ORIGINAL GRADE MT22CO291.1 Benjamin Schiller CE 12592 R E GISTEREDPROFE S S I O N A LENGINEER9/15/22 PERMIT # OSP211401 PID # 017-151-22 PALATERRA ADDN, LOT 9 DRAINFIELD ROCK Northern Geotechnical Engineering, Inc. Terra Firma Testing 11301 Olive Lane Anchorage, AK 99515 (907)344-5934 Soils Log - Percolation Test (ENGINES nityofA Nkiwiter and Project Name/No.: Proposed Lots 1-11, Palaterra Subd. / 5969-21 Date Performed: June 17 2021 Legal Description: Proposed Lot 9, Palaterra Subd. Test Performed For: Colony Builders, Inc. Slope Site Plan Depth Borehole ID: P9 P11 (feet) Drilled On: 6/16/21 OL P10 _. ss•?ss 3- 4-I�- r= �:�Im mill 9- 10- 12- -10-12- SM 13- 14- - 15- 16- 17- 18- 19- 20- 21- 22- 23- 24- 25-1 COMMENTS 6-17-18-19-20- 21- 22- 23- 24- 25- COMMENTS WAS GROUNDWATER Date Gross Time Start/Stop (HH:MM) OBSERVED ATD? No Net Drop (inches) ) 1 6/17/21 08:37 / 09:07 IF YES, AT WHAT DEPTH? NIA L 2 O MEASURED DEPTH TO None 1 10/16 GROUNDWATER E E DATE OF MEASUREMENT 6125/21 Reading No. Date Gross Time Start/Stop (HH:MM) Net Time Minutes ( ) Dp Depth to Water Start/Stop (feet BTOC) Net Drop (inches) ) 1 6/17/21 08:37 / 09:07 30 12.560 / 12.965 414/16 2 09:11 / 09:21 10 12.560 / 12.695 1 10/16 3 09:23 / 09:33 10 12.560 / 12.690 19/16 4 09:34 / 09:44 10 12.560 / 12.690 19/16 5 09:45 / 09:55 10 12.560 / 12.695 1 10/16 6 09:58 / 10:08 10 12.560 / 12.695 110/16 7 10:10 / 10:20 10 12.560 / 12.690 19/16 FINAL PERCOLATION RATE 6 (minutes/inch) PERC HOLE/CASING DIAMETER 6 in./4 in. TEST RUN BETWEEN 10.60 FT AND 11.10 FT BGS CASING S/U 1.96 PERFORMED BY: Andrew C. Smith CPG I Keith F. Mobley, P.E. CERTIFY THAT THIS TEST WAS DGD1=(IDPAE=n 11\1 Ar`(`nDr)AK1( G UI1TW AI I QTATI= AKIII RAI 1K11!'`IDA1 !3I iinr-i INFQ IN GGGFr'T nhl TI-IIQ r14TG nATG- 7/9/91 :.. U i w �490 Pump Installation Well Drilling Permit Number: Bate of Issue: Parcel Identification Number: - - Legal Description Block . Lot Property Owner Name & Address: COLONY BUILDERS FBO THAYNE & SHEVAUN HACKING PALATERA ADDITION 2 r 9 13400 DEPALATIS CIRCLE ANCHORAGE, AK 99516 Pump Installation Date: 06 _ 23 _ 2022 Pump Intake Depth Below Top of Well Casing: 280 feet Pump Manufacturer's Name: "' `_L_ Pump Model: 100C31318S21 Pump Size: 1.0 hp Pitless Adapter Burial Depth: 12 feet Pitless Adapter Manufacturer's Name: BAKER Pitless Adapter Installer• ANCHORAGE WELL & PUMP SERVICE Well Disinfected Upon Completion?Yes ❑ No Method of Disinfection: PELLETS Comments: Pump Installer Name: _ ANCHORAGE WELL & PUMP SERVICE 7640 KING STREET Company: ANCHORAGE, AK 99518 Mailing Address: 907-243-0740 City: State: Zip: Attention: The pump installer shall provide a pump installation log to On-site within 30 days of pump installation. Alpine Drilling & Enterprises Permit Number: #SW211401 Date of Issue: 9-22-21 Parcel Identification Number: 01715122000 Date Started: 4-10-22 Date Completed: 4-15-22 Is well located at approved permit location?'x Yes ❑ No Legal Description: Palaterra Block 2A Lot 9 Property Owner Name & Address: Colony Builders 9420 Vanguard Drive Anchoraae. Alaska 99507 Borehole Data: Depth (ft) Soil Type, Thickness &Water Strata From To Method of Drilling x air rotary ❑cable tool Casing type: steel stick-up 0 2 Wall Thickness: .250 inches Gravelly silt sandy- salt _ 2 13 13 21 Diameter: 6 inches Depth: 293 feet Liner Type: Diameter: inches Depth: feet silt 21 128 Casing stickup above ground: 2 feet Static water level (from ground level): 219 feet silty sandy gravel small amt water 128 134 gravelly silt 134 176 Pumping level: 290 feet after silt silty gravel small amt water 176 180 180 184 2 hours pumping 6 gpm -Recovery te: _6 _gpmMethod of Testing: air li gravelly silt 184 221 Well Intake Opening Type: silt 221 230 x Open End ❑ Open Hole gravelly silt silty water sand& gravel 230 284 284 291 ❑ Screened Start feet Stopped feet ❑ Perforations Start feet Stopped feet Grout Type: hentonite granules Volume: I hg De the Start 0 feet Sto ed ? feet gravelly silt 291 293 Pump: Intake Depth feet Pump size hp Brand Name Well Disinfected Upon Completion? x Yes ❑ No .WATER. 06Ty TCoU100 L ESTING-- Cofform -- Method of Disinfection: chlorine tablets Comments: Wrates 3 mg/L u9/L Well Driller: Alpine Drilling & Enterprises Arswic PO Box 110496 �! 3 d I Z2 Anchorage AK 99511 ® 10 ' 31Va S I Hl 13S S83NUOD ON : 31ON 6Sd 6 — ON sor 'e'd v)isvv `1O usia ONIaNO338 3MOHONV •S3Nn 33N3d 80 AHVaNn08 ONIHsnsvLs3 ZZOZ/L/6 626ZMS 2103 NO NOI13n211SNO3 Hoo a3Sn 38 N0383H 31VO OIND Viva ANV mnOHS s3ONV.LSWn3m ON N3aNn f�S _9*Z 3NOHd 'Wd NOISWaenS a3aMO338 3H1 NO 21V3ddV SVIV `30VHOHONV UN3VGSV3 ANV d0 33N31SIX3 3Hl 3NIW2 ma Ol 83NMO 3H1 40 A1n181SNOdS3N 3H1 SI 11 'a31V31aNl SV 1d33X3 1SIX3 SIN3NIH3VO83N3 ON 1VHi aNV 3A08V GROUT] kMdONd 3Hl a3A3A21nS 3AVH 11VHi A LL833 A83H3H I .OZ=,, l :31VOS 1i`dl"® ONi lin .C6 £'9£ .0,L t a GQ 0 0a o's n mC o _ xA Z .07 .0'8 o 00 V � O m 10'9{4 'S'1'21 `IaIVISVO 'V AA3P 311 `JN I A3AunS M&M IalV1SVO �p1 �Duoissa�o., J ZZOZ/L/6 °•e 'lO1i� 1609 -SI • Aff IpIDISDE) •d Ra9149r m° 00 . ..... ........... .. H1617AV ; ; NY 1-11 n o— sv N I 3„55`p�'Q£� I .£9 60£ I I I to i� ° Im I� ARSAS OLLd3S I• z ®•* I I ONlmina HOD 9NLLSIX3 I MOO � � I —.� L — — — — — — — — — — — — — ,YC. V 6i .7II1-ZftIVOOLS .l MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Water & Wastewater System Permit Permit Number: OSP211401 Work Type: WellSeptic Initial Effective Date: Expiration Date Tax Code Number: 01715122000 1 Site Legal Address: PALATERRA BLK 2A G:2939 (Propose -d Lo+ 9) Site Mailing Address: en t7 o llcparmient 9/22/2021 9/22/2022 Owner: COLONY BUILDERS INC - - - - Lot Size in Sq Ft: 648826 Design Engineer: FORGE ENGINEERING Total Bedrooms: 5 This permit is for the construction of: Q Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy Q Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Veronica Pope GE 2021.09.22 Received By: 13:27:41 -08'00' Date: Issued By: Date: •2 2 0�0 MUMUPALITY OF ANCHORAGE Community Development Department y Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On -Site Water & Wastewater Program ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 017-151-22 Property owner(s) Colony Builders Day phone 907-345-0371 Mailing address 9420 Vanguard Dr, Anchorage, AK 99507 Site address NHN Depalatis Circle 1 Legal description (Sub'd., Block & Lot) PalaterraO 181 k 2 A CProyo.5,J- L,1 91 Legal description (Township, Range & Section) Lot Size 45,853 Sq. Ft. Number of Bedrooms 5 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (® all that apply) Absorption Field ❑X Initial ❑X Single Family (SF) ❑X (w/wo AD U) Septic Tank ❑X Upgrade ❑ (D) ❑ Holding Tank ElRenewal ElDuplex Multiple Multiple Dwellings ❑ Privy El and/or D) Private Well ❑X Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: -#/ Date of Payment: 4 20 a4? l Receipt Number: C1191 b Permit No. Permit App_'-'-:. Waiver Fees: Date of Payment: Receipt Number: Waiver No. September 20, 2021 MOA Development Services, On-Site Water & Wastewater Program 4700 Elmore Rd Anchorage, AK 99507 9/20/21 Subject: Palaterra B2A (Proposed Lot 9) – Depalatis Circle Septic system design Dear On-Site Services Engineer: The owner of the above lot intends to build a 5-bedroom home on the property, so we are submitting this permit application for the construction of a new well and septic system. The attached site plan identifies the location of the home as well as the proposed well, septic location and alternate site. No conflicts exist between this proposed system and any other well or septic system, whether on this lot or adjacent lots. The ground surface on the lot is mildly sloped at less than 10%. There are no slopes greater than 25% within 50 feet downslope of either the primary or alternate site. Contours are shown on the site plan showing the grade and direction of flow. Stormwater drainage will not impact this septic system. The new trench will be constructed parallel to the slope as much as possible. Wells on adjacent lots are shown. The new system will be a minimum of 100’ from all wells and surface water, and more than 5’ away from the septic tank. The alternate site is located more than 16’ away. Please refer to the attached test hole logs, soils lab analysis, plan and profile pages for the septic design. If this design is followed, there will be no adverse impacts to adjacent properties. Sincerely, Michael E. Anderson, PE Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP211401, Rebecca Carroll, 09/22/21 NOTE: NO SLOPES >25% ARE WITHIN 50' OF THE PROPOSED SEPTIC SYSTEM. NO SURFACE WATER WITHIN 100' OF THE SEPTIC SYSTEM. ALL WELLS ON SURROUNDING LOTS WITH IMPACTS TO THIS PROPERTY ARE SHOWN. NO CONFLICTS WITH WELLS OR SEPTIC SYSTEMS. CO - CLEANOUT 2CO - DOUBLE CLEANOUT FCO - FOUNDATION CLEANOUT FD - FLOW DIVERTER VALVE MH - MANHOLE MT - MONITORING TUBE SV - SEPTIC VENT TH - TEST HOLE LEGEND 1"=40' 5-BDRM HOME FCO PALATERRA SUB, B2A (PROPOSED LOT 9) FEET 0 40 80 September 21, 2021 DEPALATIS CIRCLEP9 NGE 2021 1,500 GALLON SEPTIC TANK w/ 20" MANWAY PROPOSED WELLS w/ 100' RADII 2CO CO MT CO 60' LONG x 3' WIDE x 8' EFFECTIVE DEPTH ABSORPTION TRENCH ALTERNATE SITE 896 900 905 908 904 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP211401, Rebecca Carroll, 09/22/21 PALATERRA SUB, B2A (PROPOSED LOT 9) TYPICAL TRENCH SECTION (NO SCALE) NOTES: 1. GRADE AREA OVER TRENCH TO DRAIN AWAY 2. PROVIDE 3' OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2' WITH 2" OF INSULATION 3. CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY 4" PERFORATED PVC (HOLES DOWN) DRAINFIELD ROCK 3' 6" 6" 3'-6" 8' DESIGN FACTORS:SYSTEM REQUIREMENTS: 750 GPD PEAK FLOW PERK RATE: 6 MIN/IN APPLICATION RATE: 0.8 GPD/SF 8' DEEP TRENCH SYSTEM 1,500-GAL SEPTIC TANK w/ 20" MANWAY BOTTOM OF TRENCH: 12' BELOW GRADE FLOW LINE ELEVATION: 4' BELOW GRADE TOP OF TRENCH: 6" ABOVE GRADE 750 GPD / 0.8 GPD/SF / 8 DEEP / 2 SIDES = 58.6 LF TRENCH REQUIRED (60 LF SPECIFIED) September 20, 2021 GEOTEXTILE FABRIC Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP211401, Rebecca Carroll, 09/22/21 Proposed Lot , Palaterra Subd. 6 in. 1 /21 June , 2021 6/ /21 /21 Proposed Lots 1-11, Palaterra Subd. / 5969-21 Colony Builders, Inc. No N/A None 1 Andrew C. Smith, CPG Keith F. Mobley, P.E. 2 6 1 7 10 1 10 10 10 10 10 /16 /16 /16 /16 /16 /16 /16 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP211401, Rebecca Carroll, 09/22/21 Certificate of On -Site Systems Approval Parcel I.D. 017-151-22 Legal description Palaterra Addn @2 Lot 9 Site address 13400 De Palatis Circle , Anchorage Current property owner(s) Colony Expiration Date: 12-21-22 X The On-site system(s) is/are approved for 5 bedrooms _ Conditional_approval_for_ bedrooms, with--the--following-stipulations: Comments or advisories: MI Itl Original Certificate Date:_2 —21-22- This 2-22. This Certificate of On -Site Systems Approval (COSA) is intended to demonstrate the subject system(s) is/are in substantial compliance with municipal code. The Municipality of Anchorage, Development Services Department (DSD) issues COSAs based upon representations provided by an independent professional engineer. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. ATTACHMENTS: COSA Checklist X Well Flow Advisory Absorption Field Advisory Nitrate Advisory Tank Age Advisory Arsenic Advisory Other COSA ApprovaIjune 2022 Development Services Department i Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Certificate of On -Site Systems Approval Application 1. GENERAL INFORMATION Parcel I.D. 017-151-22 Complete legal description Palaterra Addn #2, Lot 9 Location (site address) 13400 De Palatis Circle, Anchorage, AK 99516 Current property owner(s) Colony Builders, Inc Day phone (907) 345-0371 2. ON-SITE SYSTEMS SIZED FOR 5 BEDROOMS T-YPE-OF-WA-T-ER SUPPLY: 0 Private Well -O-Private Well serving 2 dwelling units ❑ Private Well serving 3+ dwelling units ❑ Community Well or Public ❑ Water Storage 4. TYPE OF WASTEWATER DISPOSAL: ❑® Private Septic ❑ Private Septic serving 2 dwelling units ❑ Holding Tank ❑ Community Septic or Public Sewer 5. SEPTIC TANK: ❑ Steel 0 Plastic ❑ Concrete ❑ Fiberglass Age < 1 yr - See advisory if steel older than 20 years 6. ABSORPTION FIELD: ❑ AWWTS ❑ Bed X Deep Trench ❑ Wide Trench ❑ Seepage Pit Waiver request for: Expedited review requested: ❑i Distance: By applying for this entitlement, this property is subject to inspection by municipal On-site staff to verify the accuracy of the information provided. COSA Fee $ 75 + (Zd Waiver Fee $ Date of Payment !q 1.22- 0?T?7 C,) Date of Payment COSA # 0 Z2 / V& S-_ Waiver # COSA Application_ June 2022 Legal Description: Palaterra Addn #2, Lot 9 Parcel ID: 017-151-22 If more than 1 well and/or septic system on lot, provide separate checklist. Structure served by this system A. WELL DATA ❑ Well log is filed with Onsite (or attached) Date drilled 4/10/22 Total depth 293 ft Cased to 293 ft OR Sanitary seal is functioning correctly ❑ Wires are properly protected Casing height (above ground) 24 in. Date of flow test for COSA 4/15/22 Static water level at beginning of test 219 ft. Comments B. TANK DATA _Measured_ operating..fluid.level in_septic.tank --- -- Date of pumping ❑ Required maintenance completed, if AWWTS Comments: New Installation D. ABSORPTION FIELD DATA Which system tested (date installed) 11/17/21 ❑ ALL standpipes present per record drawing Total measured depth from grade 14.6 ft (max) Measured depth to pipe invert from grade 6.6 ft (min) ❑ N/A — pressurized field. ❑ Per record drawings, field is insulated. ❑ Monitor tubes go to bottom of effective. If not, state depth into effective ❑ Presoaked required if (Required if house vacant or field not used for more than 30 days prior to date of test) Gallons introduced N/A gallons N/A date Any rejuvenation treatment (past 12 months) N/A If yes, enter date Comments/Deficiencies: COSA Checklist June 2022 Well production at time of test 6 gpm Water storage tank volume N/A gallons Well disinfected for coliform test? ❑ Yes ❑ No ❑ Coliform bacteria is Negative Nitrate 1.39 mg/L ❑ Nitrate less than MRL (ND) Arsenic ug/L ❑ Arsenic less than MRL (ND) Collected by Forge Engineering Date 8/30/22 & 9/13/22 C. LIFT STATION nce completed _ Age of lift station Lift station material Comments: Adequacy test date NEW Results ❑ Pass id depth prior to test in Watadded gal New flui epth in Elapsed time min Final fluid depth in Absorption rate � gpd FIELD STATUS — POST ECOVERY Effective depth (per record wings) Effective depth used in Effective depth remaining in in E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well on lot) Septic Tank/Lift Station on Lot > 100' Community Sewer Manhole/Cleanout > 100' Yes if No ft 0 Yes if No ft Neighboring Tank > 100' Q Yes if No ft Private Sewer/Septic Line > 25' ❑ Yes if No ft Absorption Field on Lot > 100' 0 Yes if No ft Holding Tank > 100' Q Yes if No ft Neighboring Absorption Fields > 100' Animal Containment > 50' Q Yes if No ft Yes if No ft Manure/Animal Excreta Storage > 100' Community Sewer Main > 75' Q Yes if No ft Q Yes if No ft ❑ N/A — Served by Community Well (not on lot) or Public Water From Septic/Holding Tank and Absorption Field(s) on Lot to: (Please enter distances if less than required) Building Foundations > 10' Fm -1 Yes if No ft Surface Water > 100' [j] Yes if No ft Tank to Property Line > 5' [E Yes if No ft Wells on Adjacent Lots: Field to Property Line > 10' 0 Yes if No ft Private Wells > 100' Fe -1 Yes if No ft Water Main > 10' Yes if No ft Community -Wells >_200' ___ .Yes, _if.No ft Water Service Line > 10' Fm_1 Yes if No ft F. ENGINEER'S COMMENTS If tank or field is under driveway comment below G. CERTIFICATION & STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines, indicates that the on-site water supply and/or wastewater disposal system appears to comply with applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation, unless noted otherwise. Name of Firm Forge Engineering Engineer's Printed Name Benjamin Schiller, P. E. COSA Checklist—June 2022 Prone (907) 522-7773 Date 9/15/22 -����*44 -149 -* / • .::. t ....... Beniarr r =Schiller �� �F� •. CE 12AW 592 ���`��PROFESS10N0. .m