HomeMy WebLinkAboutFIRE STATION BLK 1 LT 11BOnsite File
FIRE STATION
Block 1
Lot 11B
#051-062-76
DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION
ENVIRONMENTAL ENGINEERING DIVISION
825 L Street- Anchorage, Alaska 99501 Telephone 264-4720
ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
' PHONE
JWell I ~sorPtion area
~ DISTANCE TO: Dw ~ P MIT O.
~ Manufacturer ~ I --~:"
~ ~ ~ , ~( No, of compartments
Li"':/$~n"~"°"~ '~ HOME.DE: Insidelengtb Width Liquid depth
~ ~ ~ DISTANCE TO: Well Dwelling PERMIT NO.
~ -- ~ Manufacturer Material Liquid capacity in gallons
~ DISTANCE TO: Wo'I~o ¢,t/ Foundation I,'
-- NO. of lines ~ Len~t~ of each llneo ,~1 Tota~gth of lines Trenc~wJdth inches Dis~n[ePE~i~N~ ~ ~be'ween lines
~ Top of tile to finlsh grade -- Mat~;I b~neath tile ~
m Well Building foundation Nearest lot line
~ DISTANCE TO:
~ Class Depth Driller Distance to lot line PERMIT NO.
~ DISTANCE TO: Building foundation Sewer llne Septic tank Absorption area(s)
OTHER
PIPE MATE?~ [ ,
, ....
BPPL I CBNT
LOC:RTION
LEGRL
[)CPBRTMEN]~ ? HERLTH BND ENVIRONMENTBi~ ROTECTION
........ ~ .~TREET., BNC:HORRGE BK.
264-4720
~E~-~ER F'E~: f,1 Z T
CHLGIRF':.' FIRE & RE.=,_.UE'-P
INLET ",,'IEW DR
TiSN RiW_,_.c%' NW4 _E4q
T'T'PE OF '=' -"--- ,~'-
_,OIL HE,_,uRF1 IuN.=,~'.=,TEH'-'"- ' I=,.'-'
F'O BU,, ~-~ I ....
-',6_ _.HLIGI~k. Rf.,":
LOT _, I,..E
TRENCH
29¢80 SQUBRE FEET
MRXIMUM NLIMBER OF BEDROOMS = '~:
'_-]OIL RRTING "'-- -
.=,&~ FT,.'BR) =
THE REQUIRED _.I~-E OF THE -,OIL HB--,LIRPTIuN -,~_,TEM IS:
[-~EPTH= :tE~ LEI'~GTH= '-)- '--:" -
'~- '~- L3F-:R%mEL [:'EPTH= ¢:_.
THE LENGTH DIMENSION IS THE LENGTH (IN FEET:) OF THE TRENCH OR DR~INFIELD.
THE DEPTH OF B TRENCH OR PIT IS ]'HE DISTANCE BETWEEN THE SURFBCE OF THE
GROUND BND THE BOTTOM OF THE E×CBVBTION (IN FEET).
THERE IS NO BET WIDTH FOR TRENCHES.
THE GRBVEL DEPTH IS THE MINIMUM DEPTH OF GRBVEL BETWEEN THE OUTFBLL PIPE
~ND ]'HE BOTTOM OF THE EXCBVBTION (IN FEET).
F.' E l--] i_. _! ]: REC, SEPT I L--:. T R ~'-4 [:: 'S
PERMIT BPF'I_ICRNT HRS THE REz, PON_IBILIT~ TO INFLRM THIS DEPRRTMENT E:,_RING THE
INSTRLLBTION IN-.FE£.TIUN~ OF BN~r' WELLS RDJRCENT TO THIS PROPERT'¢ BND THE
NUMBER OF RE_,IE:,ENCE=, THRT THE WELL WILL SERVE.
BHCkFILLIN~4 ~]F RN'¢ S~_,TEfl WITHOUT FINRL IN_,PECTIuN RN[> HFFE_~%RL THIS
DEF'RRTMENT WILL DE SUBJECT TO PROSECUTION,
MINIMUM DISTBNCE BETWEEN B NELL BND BN? ON-BITE SEWBGE DISPOSBL SVSTEM IS
100 FEET FOR B PRIVBTE WELL OR ~50 TO ~00 FEET FROM R PUBLIC WELL DEPENDING
UPON THE T9PE OF PUBLIC WELL
MINIMUM DISTBNCE FROM B PRIVBTE WELL TO B PRIVBTE SEWER LINE IS 25 FEET BND
TO B COMMUNITb' SEWER LINE IS 75 FEET.
OTHER REQUIREMENTS MBY BPPL9. SPECIFICBTIONS RND CONSTRUCTION DIBGRBMS BRE
BVBILBBL.E TO INSURE PROPER INSTBLLBTION.
F"ERI'.I I T E::-(F' I RES C'EL-:EI'.IBER --'---~-.1..
I CERTIFS' THRT
1: I BM FRMILIBR WITH THE REQUIREMENTS FOR ON-SITE SEWERS RND WELLS RS SET
FORTH B'¢ THE MUNICIPRLIT'¢ OF RNCHORBGE.
2: I WILL INSTBLL THE S'¢STEM IN RCCORDRNCE WITH THE CODES,
~: I UNDERSTRND THBT THE ON-SITE SEWER S~'STEM MB'¢ REQUIRE ENLRRGEMENT IF THE
RESIDENCE IS REMODELED TO INCLUDE MORE THRN 3: BEDROOMS.
RPPI~T' CHUGIRK FIRE & REb~:UE
ISSUED " " "~'. ~*'~"- -." - ~¢:1 ' ~'/
~ ';--"7 ........... [: ......~'"~ .... --~ - -(,-~ .... V4. 0
825 "L" STREET
ANCHORAGE, ALASKA 99501
(907) 264-4111
GEORGE M. SULLIV,4AI,
MA YOR
DEPAR'I'MEFJT OF HEAL'I'H AND ENVIRONMENTAL PROTECTION
December 31, 1980
Chugiak Fire and Rescue
Post Office Box 363
Chugiak, Alaska 99567
Permit ~ 800369
Subject: T15N R1W Section 3 NW¼ SE¼
A permit issued by this department for well and/or sewer
system has expired as of this date.
Permits are issued on a calendar year basis, as stated on
the permit, by authority of Municipal Ordinance.
If you have drilled the well, a well log should be sent
to this department to document the installation date.
If an engineer inspected the installation of the on,site
sewer system, please have them send us the as-builts for
our files.
If there are any further questions, please call this
office at 264-4'720.
Sincerely,
Les N. Buchholz, R.S.~ c~ci
Senior Environmental alist
LNB/ljw
enc: Copy of Permit
SWP/057
F'K~M I T NO.
825 "L-~ STREET. FINCHCRRGE. Fi~::. 264-47'20
RF'PLIF:RNT CHI IGIBK FIRE ,~. RE_,L. UE _-, P.O. BO>'; --'"-'
~ -. .~.b-'. CHI IGI RE.,
L-]CHTION INLET ',,,'IEN DR.
LEGRI TiSN R'iW SEC: _~ C]L~IO %~_'l,uI LOT -,I~E
TVF'E F~F -,OIL RE,-,ORFTIuN '-'"-
· =,'r~TEM I_. TRENCH
29000 SQURRE FEET
MBXIMUM NUMBER OF BEDROOMS = ~ SOIL RRTING (SQ FT,."BR)= 85
THE REQUIRED SIZE OF THE SOIL RBSORPTION SYSTEM IS~
[:.EPTH= 10 L E ~'-*~ ~S T H= 22 ¢'~ ~-: R"-.-' E L [)EPTH= es
THE LENGTH DIMENSION IS THE LENGTH (IN FEET) OF THE TRENCH OR DRRINFIELD.
THE DEPTH OF R TRENCH OR PIT IS THE DISTFINCE BETWEEN THE SURFRCE OF THE
GR]IIND RND THE BOTTOM OF THE E,%E.R,RTILN (IN PEET).
THERE IS NO SET NIDTH FOR TRENCHES.
THE GRRVEL DEPTH IS THE MIHIHUM DEF'TH OF GRRVEL E'ETNEEN THE OUTFRLL PIPE
RND THE BOTTOM OF THE EXCRVRTION (IN FEET).
RE~LI I RED SEF'T I C: TRf-~[~: S I ZE= 18C~C4 GRLLC,~4S
PERMIT RPPLIC:RNT HRS THE RE~FLN~IEILITk TO INFORM THIS DEPRRTMENT DURING THE
INSTRLLRTION INSPECTIONS OF RN'¢ NELLS RDJRCENT TO THIS PROPERTY' RND THE
NUMBER OF RE_IEEN.E~ THFIT THE WELL WILL -ER,E.
Tl.4Ci ~:: 2 ) I N'---]F"EI__.--T ir L]i'-.t$ RF-:E RE~..~LI I RED.
BRCKFILLING OF RNY -~_,TEH NITHOUT FINRL INSPECTION RN[:, RPPROVRL B'.,.' THIS
DEPRRTMENT WILL BE ~UE, JEL. T TO PRO_,EL. UTIBN,
MINIMUM DI'"']TRNC:E BETWEEN R WELL RND RN"r' ON-SITE SEWRGE DISPOSRL -~TEM I_-,
100 FEET FOR B PRIVFITE WELL OR 150 TO 2~')0 FEET FROM ~ PUBLIC: NELL DEPENDING
UF'ON THE T'r'PE OF PLBLIL. WELL, I -'
MINIMUM DISTFINCE FROM ~ PRI',,,'FITE NELL TO Fi PRIVFiTE SEWER LINE IS ~,'~
~..., FEET FiND
TO B C:OMMUNIT'¢ SENER LINE IS 75 FEET.
] ,
LTHER REt.]LIREMENTS MFi'¢ FiPPL~r', SPECIFICFiTIONS ~ND CONSTRUCTION DIFiI.3RFiMS FiRE
W,,,'RILFIBLE TO INSLIRE PROPER INSTBLLRTION. '
PERr'I I T E.'---.' P I RES DEC:Er'IBER -~-
_-2L..
I CERTIF'¢ THFIT
i: I BM FFIMILIRR NITH THE R - ,-
.EL4UIREMENT=, FOR ON-SITE -EWER_ 8ND WELLS H=, =,ET
FORTH BY THE MUHICIF'RLITb' OF RNCHORRGE.
'>' I WILL INSTRLL THE ~'"-
~. -,~TEH IN RCCORDRNCE WITH THE CODES.
~" I UNDERSTRND THRT THE ON-SITE SEWER =,S'-,TEM MR~' REQUIRE ENLRRGEMENT IF THE
RE_,I[ENE. E I=, REMODELED TO INCLUDE MORE THRN ~ EEDROOfl=,.
~ ,%__Z. ~ [] SOILS~
MUNICIPALITY OF ANCHORAGE
[] PERCOLATION
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
TEST
Pouch 6650, Anchorage,_..Als.~ka 99502 276-2221
SOILS LOG -- PERCOLATION TEST
14-
15
16-.
17
18
19
20 -
Readin9 Date
Time Time Water Drop
ChuXc'ak Volunteer Fire Co.,
P. O. Box 363
Chugiak, Ak. 99567
*2,
/X,;Z> O.~--:c,-/ o,O) .o c'
Note:
DIRECTIONS TO PROPERTY TO BE INSPECTbD
Sewer and Water Program
be sure to put colour of house or othe~
landmarks that will make it easy for the
inspector to find. Accurate directions
will save time and not cause delays in
scheduling.
SWP/025