Loading...
HomeMy WebLinkAboutASPEN HIGHLANDS #3 BLK 3 LT 1Onsite File Aspen Highlands #3 Block 3 Lot 1 #017-013-85 AS-BUILT OF: SCALE: GRID No: WORK ORDER No. DRAWN:CHECKED: DATE: FB BOOK/PAGE: EXCLUSION NOTES: It is the owners responsibility to determine the existence of any easements, covenants, or restrictions which do not appear on the Plat used for this survey. NOTE: Under no circumstances should any data hereon be used for construction or for the establishing of property lines. Found Rebar ZONING: SURVEY CERTIFICATION: ARI has conducted a physical survey of the subject property, the improvements situated thereon are within the property lines as shown. (T.B.D.)To Be Determined 1.Bearings and distances are record per referenced plat unless otherwise noted. 2.It is the responsibility of the person staking the location of the house to verify that the house location does not encroach adjoining parcels, Rights-of Way, or MOA setback requirements. Lot 1, Block 3, Aspen Highlands Subdivision Unit No. 3, Anchorage, Alaska May 20, 2026 60' MECB 2840 160/34 R6 PREPARED FOR: Kevin Easley 1101'Ground Elevation Clean Out Existing Well ALASKA REMOTE IMAGING Surveying Mapping Land Planning LIDAR 6239 B Street, Suite 201, Anchorage, Alaska 99518 (907) 519-0339 survey@alaskaremoteimaging.com IMAGING SURVEYING DRAFTING S U R V E Y I N G AL A S K A Taylor Maxwell Moore LS-14444 R E GISTEREDPROFESSIO N A L L A N D SU R VEYOR 5/20/26 Job No. 22-102 Permit No: OSP211469 MmW Drilling, Inc. ♦ P.O. Box 110389 + Anchorage, AK 99511 ♦ 907-345-4000 GROUNDWATER WELL LOG Well Owner: Jeremy Mohs Use of Well: Domestic Site Description: 12801 Midori Dr., Anchorage, Alaska Legal Description. Lot 1, Block 3, Aspen Highlands Subdivision Well Coordinates: Lat: 61.1047 Long:-149.7402 CONSTRUCTION Drill Method: Air rotary Hole Size: 6" Well Depth: 308' Casing Material: A53B steel Casing Size: 6" Wall: .250 Cased to: 43.37' Well Completion: Open end: X Screen: Liner: Perforated: Method: Screen/Perforation Description: Grout Notes: 2 sacks (50#ea) of bentonite Well Development: Air surge Well Disinfected: yes F Method: Chlorine bleach Yield Test at 1.5 GPM for 1 hour(s) with 100% of drawdown (DD) from static level (SWL). Method: Air lift Static Water Level (SWL): 72' Start Date: 8/8/22 Completion Date: 8/10/22 Test Pump Date: n/a Final Pump Install Date: WELL LOG Depth in feet from top of casing. Details of formations penetrated, size of material, color and miscellaneous details. 0 TO 2 ................................................................................................................ Casin..... I ... Ig Stickup .... I ......... I ...........2 TO 42 ................ ............ I ........ I .................. ............................................. Gravel: silty, some clay, medium .... I ......... I ........... I .......... I ............................................ ...........................................................42 Tp 308 .............. I .......................................... I ......................................................................... Bedrock: small water fractures from 182' to 225' TO ........ ............. I ... I ......................TO .................................................. ............... ................ I ............... M'= .... DRILUMG ......... I'N'C ... 0 ............................... ......................................... I ............ I ................. ......... I ....................... I ............... I.... ............... I ..................... I .................. .... .....................TO .................................................. .................................... I ............... I ...... ­­ ... I R-0-8 ..... SOX ... 11"0389 .... ................................... ­ ................... ....................................................................................... ... ............................ " ............. I ..................................................... ................ I ............. _._T0 ........ _...... _ .............._ ANCHQRAGE, A.LASKA.995i... 1.......................................................................................................................................................... ......................................._........ . TO TO TO WAYNE E. WESTBERG ............................................................................................................................................................ l ­ ....... ............................................................................................................................................................................................................... c President, M-W DrElling, In........ ...' ........ - ...... " ................................................................................. .�..... .............,...___...._..................NfiVIfA-Cerfitied-MasterGroundwater-Gont�acto�........................................................._�......... _....................... _ _ ............................................TQ....._....._�_....._ _._..................._................................_Ak. Gen._Contr_lic_No 1000 TO SGSi- SGS Ref.# 1261513001 Client Name M-W Drilling Printed Date/Time 05/04/2026 16:56 Project Name/# 12801 Midori Drive Collected Date/Time 04/27/2026 14:00 Client Sample ID Sink Received Date/Time 04/27/2026 15:35 Matrix Drinking Water Technical Director Stephen C. Ede Sample Remarks: Allowable Prep Analysis Parameter Results LOQ Units Method Container ID Limits Date Date Init Metals by ICP/MS Arsenic ND 5.00 Waters Department Total Nitrate/Nitrite-N 4.74 0.200 Microbiology Laboratory E. Coli Negative I Total Coliform Negative 1 ug/L EP200.8 C (<10) 04/29/26 04/30/26 HBL mg/L SM214500NO3-F B (<10) 05/01/26 DAT IOOmL SM219223B A IOOmL SM219223B A 04/27/26 M.A 04/27/26 M.A M-W Drilling, Inc. TEST PUMP REPORT Sheet 1 of 1 Date: 4-27-26 Conducted by: Nick M-W Job #: 22-102 Owner: Kevin Easley Address: 12801 Midori Drive, Anchorage, AK Well Location: Well Info: Total Depth: 308’ Depth of Casing: 43.37’ Casing Size: 6“ Screen Slot: Screen: From to Screen Diameter: Remarks: Pump Info: Make: FPS Model: 10FRD1P4-2W230 HP: 1 Volts: 230 Pump Diam: 3” Test Info: Intake Depth: 297’ Water level meas.: Water Level Indicator Pump on: Time: 11:30 Date: 4-27-26 Meter Reading: Pump off: Time: 12:45 Date: 4-27-26 Meter Reading: Static water level: 74’ Max. drawdown from SWL: 223’ Avg. discharge: 8 GPM Remarks: Time Water Level Flow GPM Remarks Time Water Level Flow GPM Remarks Clock Mins. Elpsd Clock Mins. Elpsd 11:30 0 74.0 Turn pump on 12:46 1 296.7 -0- Start recovery 11:31 1 76.5 8 12:47 2 296.4 readings 11:32 2 79.2 8 12:48 3 296.2 11:33 3 82.7 8 12:49 4 295.9 11:34 4 86.3 8 12:50 5 295.7 11:35 5 88.8 8 12:51 6 295.4 11:36 6 92.0 8 12:52 7 295.1 11:37 7 94.5 8 12:53 8 294.9 11:38 8 98.3 8 12:54 9 294.6 11:39 9 100.6 8 12:55 10 294.4 11:40 10 102.8 8 13:00 15 293.1 11:45 15 118.7 8 13:05 20 291.8 11:50 20 134.2 8 13:10 25 290.5 11:55 25 148.1 8 13:15 30 289.2 12:00 30 165.4 8 13:25 40 286.6 12:05 35 178.8 8 13:35 50 284.1 12:10 40 194.1 8 13:45 60 281.4 12:15 45 208.5 8 14:45 120 265.8 12:20 50 224.2 8 15:45 180 250.2 12:25 55 238.7 8 16:45 240 234.42 End of test 12:30 60 254.6 8 12:35 65 268.9 8 12:40 70 283.5 8 12:45 75 297.0 8 At intake; pump off MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Water & Wastewater System Permit Permit Number: OSP211469 Work Type: WellSeptic Initial Tax Code Number: 01701385000 Site Legal Address: ASPEN HIGHLANDS #3 BLK 3 LT 1 G:2840 Site Mailing Address: 12801 Midori DR, Anchorage Owner: MOHS JEREMY Design Engineer: GARNESS ENGINEERING GROUP LTD This permit is for the construction of: Effective Date: Expiration Date: �11�nr f � n � n Department Lot Size in Sq Ft: Total Bedrooms: 11/17/2021 11/17/2022 50481 Q Disposal Field 2 Septic Tank ❑ Holding Tank El Privy Q Private Well O Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Received BW7' Issued By: a" - Date: 11�/,' Date: 1 4 U IC , 3 OF ANCHORAGE $' p a ^ y. oz tet"—'rc =+ xr� �t.A ,. IR� {� Development Services Departmen� r� On -Site Water& Wastewater Section �'�- = Phone. 907-343-7904 Fax: 907-343-7997 ON-SITE SEPTIC/WELL PERMIT APPLICATION Parcel I.D. 017-013-85 Property owner(s) Jeremy Mohs Mailing address 12801 Midori Drive *Anchorage, AK Site address 12801 Midori Drive *Anchorage, AK Day phone 907-360-5962 Legal description (Sub'd., Block & Lot) Aspen Highlands #3; Block 3, Lot 1 Legal description (Township, Range & Section) Lot Size Sq. Ft. Number of Bedrooms 4 APPLICATION IS FOR: APPLICATION IS AN: (N all that apply) TYPE OF DWELLING: Absorption Field 0 Initial ❑ Single Family (SF) Z Septic Tank 0 Upgrade pg ❑ (w/wo ADU) Holding Tank El Renewal ❑ Duplex (D) El Privy ❑ Multiple Dwellings ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A WAIVER REQUEST FOR: Distance: I certify that the above information is correct. 1 further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: (0 2-0 Waiver Fees: Date of Payment: T 0 02 Date of Payment: Receipt Number: Q a. a 51 Receipt Number: Permit No. _�S /0 2 q Waiver No. GADevelopment Services\Building Safety\On Site Water and Wastewater\Forms\Client FormsTermit Application.doc Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP211469, Rebecca Carroll, 11/17/21 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP211469, Rebecca Carroll, 11/17/21 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP211469, Rebecca Carroll, 11/17/21 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP211469, Rebecca Carroll, 11/17/21 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP211469, Rebecca Carroll, 11/17/21 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP211469, Rebecca Carroll, 11/17/21 PROJECT CLIENT: PROJECT NAME: PROJECT NO.: SAMPLE LOC.: NUMBER/ DEPTH: DESCRIPTION: DATE RECEIVED: TESTED BY: REVIEWED BY: 100 90 80 70 60 50 ami 40 30 20 10 0 145 140 135 "' Z 130 125 120 115 0 NoRTHERN GEOTECHNICAL ENGINEERING, INC../ TERRA FIRMA TESTING Jeremy Molts 12801 Midori -Drive 6036-21 TPI S1/4-51 Poorly -graded sand w/ silt and 5/_20/2021 SPM 0, % 0 GRAVEL 29.5 % SAND 63.2 % SILT/CLAY 7.3 % MOIST. CONTENT 9.3 USCS USACOE FC % PASS. 0.02 nim % PASS. 0.002 mm SP -SM N/A N/A N/A UNIFORMITY COEFFICIENT (C.) 26.7 COEFFICIENT OF GRADATION (C.) 1.0 PLASTICITY INDEX ASTM D 1557 (uncorrected) N/A N/A ASTM D4718 (corrected) N/A OPTIMUM MOIST. CONTENT. (corrected) N/A - PARTICLE SIZE ANALYSIS ASTM D7928/C136 U.S. SIEVE OPIN"'C; IN rNCIMS I U.S.SIEVENWaER, I IrfDROMETER 3 1.5 3/4 1/23M A 67A — I T --1j, _—- SIEVE _SIZE (U.S.) TOTAL % _SPECIFICATION PASSING PASSING) I I t DEGRADATION 152.40 LILL. 1 1 PLASTICITY INDEX 76.20 3" N/A 38.10 1.5" 19-00 3/4" 61 12.70 1/2" 87 —0 3/8" 83 4.75 #4 71 71 E. - FF, 54 HILILIF #20 —1 0.43 #40 L Lill #60 18 0.15 _11 L 12 0.075 #200_ Lil L! J !_;t!! 1 [1-7, T L5, � -'i"I M, 1E :E1 100 10 1 0.1 0.01 GRAIN SIZE (mm) COBBLES VEL SAND c GRAVEL SILT or CLAY F e C." Ouse Fine coarse I Medium z MOISTURE -DENSITY RELATIONSHIP ASTM D 1557 SIEVE ANALYSIS RESULT SIEVE SIZE (mm) _—- SIEVE _SIZE (U.S.) TOTAL % _SPECIFICATION PASSING PASSING) N/A DEGRADATION 152.40 6" PLASTICITY INDEX 76.20 3" N/A 38.10 1.5" 19-00 3/4" 61 12.70 1/2" 87 9.50 3/8" 83 4.75 #4 71 2.00 #10 54 0.85 #20 38 0.43 #40 25 0.25 #60 18 0.15 #100 12 0.075 #200_ 7.3 0.001 HYDROMETER RESULT tj 4 6 8 10 12 14 16 MOISTURE CONTENT (%) oried herein have been performed to recognized industry standards, unless otherwise noted. No other warranty is made interpretation or opinion be required, NGE-TFT will provide upon written request. 11301 Olive Lane - Anchorage, Alaska 99515 - Phone: 907-344-5934 - Fax: 907-344-5993 - wivivxge-oxom —ELAPSED DIAMETER TOTAL % TIME (MIN) PASSING 0 2 5 8 15 30 60 250 :1 1 HYDRAULIC COND. (ASTM D2434) N/A DEGRADATION (ATM T-313) N/A PLASTICITY INDEX .ASTM 4318 N/A _4 =F —F —T- 1EI—F tj 4 6 8 10 12 14 16 MOISTURE CONTENT (%) oried herein have been performed to recognized industry standards, unless otherwise noted. No other warranty is made interpretation or opinion be required, NGE-TFT will provide upon written request. 11301 Olive Lane - Anchorage, Alaska 99515 - Phone: 907-344-5934 - Fax: 907-344-5993 - wivivxge-oxom —ELAPSED DIAMETER TOTAL % TIME (MIN) PASSING 0 2 5 8 15 30 60 250 :1 1 HYDRAULIC COND. (ASTM D2434) N/A DEGRADATION (ATM T-313) N/A PLASTICITY INDEX .ASTM 4318 N/A or A Municipality of Anchorage Aw Nrzcr's� � Development Services Department ® Building Safety Divisiono �9 p H On -Site Water and Wastewater Program,`, o 4700 Elmore Road P.O. Box 196650 Anchorage, AK 99507 , , ° ° °° �tirv.ci.anchoraae.ak.us ° SHF,q (907) 343-7904 -P-°° p4U RP Y o Soils Lig m Percolation Test ��o ° cE,?a»>G"'�'� Performed For: Jeremy Mohs Legal Description: Aspen Highlands 1t3 Block 3 Lot 1 1- 2- 3- 4- 5- 6- 7- 8- 9- 10- 11- 12- 13- 14- 15- 16- 17- 18- 19- 20- COMMENTS Perc Test # 2 Topsoil/Silt Sand with gravel Silt Sand with gravel WAS GROUND WATER ENCOUNTERED? NO Date Performed: 5/20/21 Township, Range, Section: 12N, 3W, 25 S Bottom Of IF YES, AT WHAT DEPTH? N/A L Hole Depth to Water After 0 Monitoring? N/A P E Date: 5/20/21 Site Plan Reading Date Gross Time Net Time Depth to Water Net Drop 5/20/21 2:25 6" 2:27 30 seconds 12.00" 6.00" 2:30 57 seconds 12.00" 6.00" 2:32 72 seconds 12.00" 6.00" 2:35 87 seconds 12.00" 6.00" 2:38 98 seconds 12.00" 6.00" o�onnn 2:41 121 seconds 12.00" 6.00" — ........ — --- v ­ .­ v rtr(U NULt UTAMETER 4" TEST RUN BETWEEN 5 FT AND 5.5 FT PERFORMED BY: Shea Murphy I Shea Murphy CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: May 20, 2021 NORTHERN GEOTECHNICAL ENGINEERING, INC. Z TERRA FIRMA TESTINL PROJECT CLIENT: Jeremy PROJECT NAME: 1-2801 Midori Drive PROJECT NO.: 6036-21 SAMPLE LOC.: TP2 NUMBER/ DEPTH: SF1 4 - 5' DESCRIPTION: Poorly --graded sand w/ silt DATE RECEIVED: 5/20/2021 TESTED BY: 19.00 ,REVIEWED BY: SPM 100 90 80 70 r4 60 50 40 30 20- 10 0 145 140 (2.1 ,e:f 135 E_ Z c" 130 125 120 115 0 0 % GRAVEL 14.5 USICS SP -SM SG % SAND 74.3 USACOE FC N/A IL % SILT/CLAY 11.2 % PASS. 0.02 mm N/A CO % MOIST. CONTENT 11.4 % PASS. 0.002 mm N/A UNIFORMITY COEFFICIENT (C.) TY C (Cu) 7 UNKNOWN UNKNOWN IE COEFFICIENT OF GRADATION (C. NT N (C.) UNKNOWN UNKNOWN ASTM D1557 (uncorrected) N/A 18 (corrected) (corrected) N/A OPTIMUM Moj� OPTIMUM MOIST. CONTENT. (corrected) 3" PARTICLE SIZE ANALYSIS ASTM D7928 / C136 U.S. ENL�' SIEVE OPG IN tNCMS I U.S. SIEVE NMITIERS 3 1.5 3/4 l23 M 'Njn din IuU 10 1 0.1 GRAIN SIZE (mm) COBBLES G!tAWL I SAND 0.01 SILT or CLAY MOISTURE -DENSITY RELATIONSHIP ASTM D 1557 SIEVE ANALYSIS RESULT SIEVE SIZE (MM) ILU TOTAL% SPECIFICATION —PASSING (/. �PASIING) N/A DEGRADATION 152.40 61' PLASTICITY INDEX LLLLI 3" N/A 38.10 1.5" 19.00 3/4" 100 12.70 L, L 1 94 g92 7 "71j 4.75 #4 Ll 11ij I 1 1 IM 711771 0.85 #20 43 0.43 #40 LLl_LL 1 0.25 #60 17 0.15 #100 14 0.075.. 1 #200 1 11.2 J iL 11 L! !M! T _LL! IuU 10 1 0.1 GRAIN SIZE (mm) COBBLES G!tAWL I SAND 0.01 SILT or CLAY MOISTURE -DENSITY RELATIONSHIP ASTM D 1557 SIEVE ANALYSIS RESULT SIEVE SIZE (MM) SIEVE SIZE (U.S) TOTAL% SPECIFICATION —PASSING (/. �PASIING) N/A DEGRADATION 152.40 61' PLASTICITY INDEX 76.20 3" N/A 38.10 1.5" 19.00 3/4" 100 12.70 1/2" 94 g92 9.50 3/8" 4.75 #4 86 100 #10 72 0.85 #20 43 0.43 #40 234 0.25 #60 17 0.15 #100 14 0.075.. 1 #200 1 11.2 0.001 HYDROMETER RESULT 0 2 testing 4 6 8 10 12 14 16 MOISTURE CONTENT (%) orted herein have been performed to recognized industry standards, unless otherwise noted. No other warranty is m, interpretation or opinion be required, NGE-TFT will provide upon written request 11301 Olive Lane - Anchorage, Alaska 99515 - Phone: 907-344-5934 - Fax: 907-344-5993 - www.nge-O.coni ELAPSED DIAMETER TOTAL % TUMAME PASSING 0 1 2 8 15 30 60 250 1440 HYDRAULIC COND. —7 (ASTM D2434) N/A DEGRADATION (ATM T-313) N/A PLASTICITY INDEX ,ASTM 4318 N/A J 0 2 testing 4 6 8 10 12 14 16 MOISTURE CONTENT (%) orted herein have been performed to recognized industry standards, unless otherwise noted. No other warranty is m, interpretation or opinion be required, NGE-TFT will provide upon written request 11301 Olive Lane - Anchorage, Alaska 99515 - Phone: 907-344-5934 - Fax: 907-344-5993 - www.nge-O.coni ELAPSED DIAMETER TOTAL % TUMAME PASSING 0 1 2 8 15 30 60 250 1440 HYDRAULIC COND. (ASTM D2434) N/A DEGRADATION (ATM T-313) N/A PLASTICITY INDEX ,ASTM 4318 N/A MUNICIPALITY OF ANCHORAGE Development Services Department F Phone: 907-343-7904 On -Site Water & Wastewater Section -- Fax: 907-343-7997 Septic System Owner -installer Agreement The On-site Water and Wastewater Section (On-site) may issue an approval for a homeowner to perform work on an on-site wastewater disposal system to serve that individual's owner - occupied, single-family or duplex home if the homeowner meets and agrees to the following requirements: 1. The property owner and excavation equipment operator may perform work on no more than one owner -installation project in a 12 -month period. 2. Owner's projected active involvement with the installation: I will be installing the system myself with help from a friend. 3. The name of the excavation equipment operator: Kice Malnerick 4. 1 agree that there will be no monetary compensation for installation services rendered. 5 The name of the inspecting engineer: David Garness 6. 1 agree to discuss the following items with the inspecting engineer: a. Permit design criteria and specifications. b. Inspection requirements set forth in AMC 15.65.070. c. Advance notice given to the On-site Water & Wastewater Section for all required municipal inspections (AMC 15.65.070A). 7. 1 agree to have the project -specific On-site Wastewater Disposal System Permit available at the construction site for the duration of all related work. & 1 agree that if the system is an advanced wastewater treatment system (AWWTS), I will obtain additional installation instructions and approval from the equipment distributor. As owner of (legal description)_ Aspen Highlands #3 LT 1 1 agree that the information above is true and accurate. Owner's printed name: Jeremy Mohs Owner's signature: - Date: to 2 Mailing Address: P. O. Box 196650 * Anchorage, Alaska 99519-6650 * www.muni.org