Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
OVERLOOK ESTATES #2 LT 7
Onsite File Overlook Estates #2 Lot 7 #068-041-39 Municipality of Anchorage On -Site Water and Wastewater Section • (907) 343-7904 Page 1 of 3 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP211478 PID Number: 068-041-39 Dwelling: ❑■ Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: 41 New ❑ Upgrade Name Eklutna Inc. ABSORPTION FIELD ❑ Deep Trench A Wide Trench ❑ Bed ❑ Mound Site Address NHN Vantage Dr, Eagle River, AK 99577 ❑ Other Phone 907-310-2501 Number of Bedrooms 4 Soil Rating JTotal depth from original grade 1.0 GPD/SF 7.0 / 7.5 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade 6.5/7.0 Ft. Gravel depth beneath pipe 0.5/.05 Ft. Subdivision Block Lot Overlook Estates #2 7 Fill added above original grade 3.0/4.2 Ft. Gravel length 60.0 / 60.0 Ft. Township Range Section Gravel width 5.0 / 5.0 a Ft. Beds: Number of Lines N/A Distance between lines N/A Ft. SEPARATION DISTANCES To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Tank Line 600 Ft2 2 6.9 Ft. Well >100' >1 00' N/A N/A >25 TANK 0 Septic ❑ S.T.E.P. ❑ Holding ❑ Other Manufacturer Greer Capacity 1250 Gal. Surface Water >100' >1 00' N/A N/A Material Plastic Number of compartments 2 Lot Line >5' >10' N/A N/A NA Foundation >1 0' >10' N/A N/A LIFT STATION IVI'an turer Capacity Remarks Gal. Alarm location Installer PIPE MATERIAL House to tank D3034 Tank to drainfield D3034 Little Dipper Excavation Drainfield D3034 CO/MTD3034 Inspector J.Millette BENCH MARK (Assumed elevation) 100 ft Inspection 15t 2/24/22 2/26/22 Location and description dates: 2nd 3,d 2/28/22 4'h Top of Garage Slab ON-SITE WATER AND WASTEWATER SECTION APPROVAL Engineer's Stamp -� of A `le Conditional Approval: Date Aw. CO 49 TH I%• '� Benjarri�ySchiller � • CE • �w��/ Septic Sytem Approved �-� j� Date 1©' . 12592 'fir ' • , 9/15/22 . •''C"® PRkW OF ESSIONP��._� OFESS Note: this approval does not include well permit requirements. t� kmev v51021 tu/ OVERLOOK ESTATES #2• LOT 7 PERMIT # OSP211478 V 460 SUBDIVISION TEST HOLE 450 AGE AVENUE 470 T&E EA EMENT ( WEL'L,.., -\. 1250 -GAL SEPTIC 4-BDRM TANK W/ 20" \ `, MANWAY ~\ 440 MH1 © CO3 „-,....__..LOT 7 MT3-- \ -,.. 2 430 \ � CP? r T,41 -ALTERNATE -.SITE: 20' LONG x 5' WIDE, 05' EFFECTIVE DEPTH CAT III, - ABSORPTION TRENCH --- CLEARING LIMITS 420` .� __... f NGI Nff RING r LOT 1 ZMATION TEST HOLE 2=60' LONG x 5' WIDE; 0.5' EFFECTIVE DEPTH ABSORP,TIO TRENCH W/ 2' SAND LINER k B FCO J-1,2.1 50.11 MH1_ 15:3 ' 59.2 SVT-'` 20.7,'! 63.5, 2CO ' /23,0 65.0 `�, FSS' 32.4 67.3 C01 33.9 59.8 MT1 ,x' 34.4 61.1 CO2 !; 85.6 `78.2 `.MT2 85.8 77.1 CO3 42.7 72A MT3; 42.9 73.4 /C04 91.5 90.5 MT4 90,5 1 89.3 ® LEGEND • !���� CO - CLEANOUT 49 TM • • rP�® PLAN AS -BUILT BLE CL FCO - FOUNDATION CLEANOUT ... � . 0 50 100 FS - FLOW SPLITTER VALVE Benja i Schiller No FEET MH - MANHOLE �Fc•., CE 2592 ���0 1"=50' MT -MONITORING TUBE P %r 920r22 '.• SV - SEPTIC VENT ��lt®®O®®o®`•��' TH - TEST HOLE OVERLOOK ESTATES #2, LOT 7 PERMIT # OSP211478 excixeea�xc MW PROFILE AS -BUILT (NO SCALE) .......... ' • • • Benja' Schiller �r�FC�d ' • CE 1 "2192 •' ���r �t\1®� PROFESSIONP�'.o" Whearon � �� � �� ��D Inco 1190 N. Wasilla-Fish hook Road Wasilla, AK 99654 (907)376-2041 Name: Hultquist Homes Address: City: Anchorage State: AK Zip Code: 99654 Well Site: Overlook #2 Lot/Block: 7 Additional: Well Depth: 445 ft. From: To: Formation: 0 2 stick up Below Ground: 443 ft. 2 28 cobble/gravel Above Ground: 2 ft. 28 47 cobble/clay/gravel Gal/Min: 0'7 47 69 gravel/cobble 69 1107 (gravel/sand Static Level: N/A 107 136 gravel/silt 136 142 gravel/sand/damp Casing: 161 ft. of 6 in. x .25 in. steel 142 143 gravel/silt/water 1/2 gpm 143 155 bedrock/grey I semi hard Liner Pipe: N/A 155 249 bedrock/grey hard w/quarts 249 250 quartz vein Screened: N/A 250 315 bedrock green w/quarts 315 426 grey bedrock Perforated: N/A 426 445 green bedrock Grouted: Yes Depth: Develop. Method: AirWATER 0 6TYTESTING ColiformCol/100ml- Use of Well: Residential Nfirates 2.0 _ L mtiL -2.. SO ug/L Drilling Method: Rotary A is t Misc: Other: The well was pumped 5' off the bottom with 100% draw down for 2 hours and recovered at 0.7gpm . Date Drilled: 5.14.2022 Driller: Seth Moore Development Services Department Building Safety Division G On Water Wastewater Program Q�� &`_< ' 4700 Elmore Road P.O. Box 196650 d c Mark Begieh Anchorage, AK 99507 Mayor www.muni.org/onsite (907) 343-7904 Pump Installation Log Well Drilling Permit Number: SW OSP211478 Date of Issue: 11/23/2021 Parcel Identification Number: 068-041-39 Legal Description Property Owner Name & Address: Overlook Estates #2 L7 Hultquist Homes 27440 Vantage Ave, Eagle River, AK 99577 12570 Old Seward Hwy #204 Anchorage, AK 99515 Pump Installation Date: 09/19/2022 Pump Intake Depth Below Top of Well Casing: 304 Pump Manufacturer's Name: Meyers Pump Model: 3/4hp 5gpm Pump Size 3/4 hp Pitless Adapter Burial Depth: 13 feet Pitless Adapter Manufacturer's Name: Campbell Pitless Adapter Installer: unknown Well Disinfected Upon Completion? ✓❑ Yes ❑ No Method of Disinfection: Sterilene Comments: Pump Installer Name: Wheaton Water Well, Inc. 1190 N. Wasilla-Fish hook Road Wasilla, AK 99654 feet Attention: The pump installer shall provide a pump installation log to the DSD within 30 days of pump installation. r CA, 4 0 0 O Ln lil v to N O O Z m �W 0 ® O 16 m 0 -cc o Q o x ° a-''- � Lo �p m win 9:3 o a cmw onvZc o N �huNi C Bonn®o �Noocc (na 0. 4 v m ]] M LO Q`�✓: -::c.: �S N���� M C9_ p, N O7) m m m O E a ROW Q ICY) Q4v�'••. Wim. Quo Y o c Y � Z m �W 0 ® O 16 m 0 -cc o Q o x ° a-''- � Lo �p m win 9:3 o a cmw onvZc o N �huNi C Bonn®o �Noocc (na 0. 4 v m �- c�m v �- my m m m O E a » •o ®`cm> Q o0 to Mgoo 0-0a i s° o m Lo a c'- c�v NmdLa) c� � m� m °'v C L IDmLCc u o> am= C� `0$ m m m r�[ F.mc+° o o m m •" i 4f m CL O m t s c � E s c N •«• 0..- 0 .° c O Br O D p v V Q a E O OZcva•~O L Zm`oaOc my °mmr, oa �_ mood0To° m`=qc�•. La cv° e X o ° m 0 w 'a O > O pi m s m c V0 tCcn—amma �-c °° —Wocmo0 -0 ..a.v)=c.sa D —it .°cp—c°°ov •too:aEc0 p�j0 Vm m >°» y L .0 E— CLID ,ca eBOCEME t C. °am °o c o � MUNICIPALITY OF ANCHORAGE ,■rent On -Site Water & Wastewater Program �o�. ;� h PO Box 196650 4700 Elmore Road . a Anchorage, Alaska 99519-$650 Phone: (907) 343-7904 Fax: (907) 343-7997 Al pilln http://www. mu n i.o rg/onsite f eparrrncitt �' n -S i#�IIIVate�--��FU�s�fiewa�ystem-Permi Permit Number: OSP211478 Effective Work Type: WellSeptic Initial Tax Code Number: 06804139000 Site Legal Address: OVERLOOK ESTATES #2 LT 7 G:0465 Site Mailing Address: Owner: EKLUTNA INC Design Engineer: FORGE ENGINEERING This permit is for the construction of: 0 Disposal Field 0 Septic Tank ❑ Holding Tank ❑ Privy Expiration Date: 11/23/2022 Lot Size in Sq Ft: 55965 Total Bedrooms: 4 RI Private Well ❑ Water Storage All construction shall be in accordance with: I. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by tailing (907) 343-7904 (2417). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Special Provisions: 1) A test hole shall be completed prior to construction of the absorption field, located as shown on the site plan. The test hole shall confirm separations to impermeables and seasonal high groundwater, as well as the percolation rate. Construction may proceed at your own risk prior to 7 -day groundwater monitoring. If results require a design change, construction shall stop pending On-site review and approval of a change order. Please submit results with the inspection report (or change order, if applicable). Veronica Pope 2021.11.23 Received By:*ikl� 12:30:55 -09'00' Issued By; I aLu'tk L�Lmx Date: Date: 20.� 1 PVgU�\lJC PDn L0 a ®F imCm0P Community Development Department Development Services Division Phone: 907-343-7904r --Fax. -907-343--7-997 -------------- ogram ON-SITE SEWER/WELL_PERMIT AP_P_LICAT-ION Parcel I.D. 068-041-39 Property owner(s) Eklutna Inc. Day phone 907-310-2501 Mailing address 16515 Centerfield Drive #100, Eagle River, AK 99577 Site address NHN Vantage Drive Legal description (Sub'd., Block & Lot) Overlook Estates #2, Lot 7 Legal description (Township, Range & Section) Lot Size 64,716 Sq. Ft. Number of Bedrooms 4 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (N all that apply) Absorption Field x❑ Initial 0 Single Family (SF)Ex] Septic Tank x❑ Upgrade 1-1(w/wo AD U) Holding Tank ❑ Renewal ❑ Duplex (D) ❑ Privy ❑ Multiple Dwellings ❑ (SF and/or D) Private Well x❑ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: .2 Waiver Fees: Date of Payment: 1 D Date of Payment: Receipt Number() 1 �i� D Receipt Number: Permit No. - 0SP a 11 Li 7 8 Waiver No. Permit App_'-'-:. .—.,:c L� November 18, 2021 MOA Development Services, On-Site Water & Wastewater Program 4700 Elmore Rd Anchorage, AK 99507 11/18/21 Subject: Overlook Est #2 L7 – NHN Vantage Drive Septic system design Dear On-Site Services Engineer: The owner of the above lot intends to build a 4-bedroom home on the property, so we are submitting this permit application for the construction of a new well and septic system. The attached site plan identifies the location of the home as well as the proposed well, septic location and alternate site. No conflicts exist between this proposed system and any other well or septic system, whether on this lot or adjacent lots. The ground surface on the lot slopes gradually toward the south. There are no slopes greater than 25% within 50 feet downslope of either the primary or alternate s ite. There are contour lines, labeled with elevations, on the site plan showing the grade and direction of flow. Stormwater drainage will not impact this septic system. The new trenches will be constructed parallel to the slope as much as possible. Wells on this and adjacent lots are shown along with the neighboring wastewater systems. The new system will be a minimum of 100’ from all wells and surface water, and more than 5’ away from the septic tank. The alternate site is located more than 6’ away. Please refer to the attached test hole logs, plan, and profile pages for the septic design. A confirmation test hole will be performed to confirm the findings of the subdivision test hole used for the permit application. If this design is followed, there will be no adverse impacts to adjacent properties. Sincerely, Benjamin Schiller, PE Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP211478, Rebecca Carroll, 11/23/21 ALTERNATE SITE: 20' LONG x 5' WIDE, 0.5' EFFECTIVE DEPTH CAT III ABSORPTION TRENCH Benjamin Schiller CE 12592R EGISTEREDPROFES S I O N ALENGINEER 1"=50' 1250-GAL SEPTIC TANK W/ 20" MANWAY CO - CLEANOUT 2CO - DOUBLE CLEANOUT FCO - FOUNDATION CLEANOUT FS - FLOW SPLITTER VALVE MH - MANHOLE MT - MONITORING TUBE SV - SEPTIC VENT TH - TEST HOLE LEGEND 2CO OVERLOOK ESTATES #2, LOT 7 FEET 0 50 100 NOTE: NO SLOPES >25% WITHIN 50' OR SURFACE WATER WITHIN 100' OF THE PROPOSED SEPTIC SYSTEM ALL WELLS ON SURROUNDING LOTS WITH IMPACTS TO THIS PROPERTY ARE SHOWN. NO CONFLICTS WITH WELLS OR SEPTIC SYSTEMS. VANTAGE AVENUE 11/18/21 10' T&E EASEMENT 10' T&E EAS E M E N T CLEARING LIMITS 420 430 440 450 460 470 2-60' LONG x 5' WIDE, 0.5' EFFECTIVE DEPTH ABSORPTION TRENCH w/ 2' SAND LINER 4-BDRM HOME CO CO CO COMT MT MT MT FCO FS PROPOSED WELL SUBDIVISION TEST HOLE CONFIRMATION TEST HOLE ≥10' EXISTING WELL Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP211478, Rebecca Carroll, 11/23/21 OVERLOOK EST #2, LOT 7 TYPICAL TRENCH SECTION (NO SCALE) NOTES: 1. GRADE AREA OVER TRENCH TO DRAIN AWAY 2. PROVIDE 3' OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2' WITH 2" OF INSULATION 3. CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY Benjamin Schiller CE 12592R EGISTEREDPROFES S I O N ALENGINEER4" PERFORATED PVC (HOLES DOWN) DRAINFIELD ROCK 5' 6" 4' 6" 2' DESIGN FACTORS:SYSTEM REQUIREMENTS: 600 GPD PEAK FLOW PERK RATE: >1 MIN/IN APPLICATION RATE: 1.0 GPD/SF 5' WIDE TRENCH SYSTEM 1250-GAL SEPTIC TANK BOTTOM OF TRENCH: 7' BELOW GRADE FLOW LINE ELEVATION: 4.5' BELOW GRADE TOP OF TRENCH: 0.5' ABOVE GRADE 600 GPD / 1 GPD/SF / 5' WIDE * 1.0 (RED. FACTOR) = 120 LF TRENCH REQUIRED (120 LF SPECIFIED) 11/18/21 GEOTEXTILE FABRIC 6" MOA APPROVED SAND Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP211478, Rebecca Carroll, 11/23/21 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP211478, Rebecca Carroll, 11/23/21 MUNICIPALITY OF ANCHORAGE f�F t Development Services Department Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Certificate of On -Site Systems Approval Parcel I.D. 068-041-39 Legal description Overlook Estates #2 Lot 7 Site address 27440 Vantage Ave, Eagle River Current property owner(s) Hultquist Homes Expiration Date: 1-10-2023 X The On-site system(s) is/are approved for 4 bedrooms Conditional approval for Comments or advisories: By: 'J .16,"'.. bedrooms, with the following stipulations: Original Certificate Date: This Certificate of On -Site Systems Approval (COSA) is intended to demonstrate the subject system(s) is/are in substantial compliance with municipal code. The Municipality of Anchorage, Development Services Department (DSD) issues COSAs based upon representations provided by an independent professional engineer. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. ATTACHMENTS: COSA Checklist X Well Flow Advisory Absorption Field Advisory Nitrate Advisory Tank Age Advisory Arsenic Advisory Other COSA Approval_June 2022 MUMUPALFV OF A HCHO' AG [E Development Services Department Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Certificate of On -Site Systems Approval Application 1. GENERAL INFORMATION Parcel I.D. 068-041-39 Complete legal description Overlook Estates #2, Lot 7 Location (Site address) 27440 Vantage Ave, Eagle River, AK 99577 Current property owner(s) HUItquist Homes 2. ON-SITE SYSTEMS SIZED FOR 4 BEDROOMS Day phone (907) 522-3204 3. TYPE OF WATER SUPPLY: ❑I■ Private Well ❑ Private Well serving 2 dwelling units ❑ Private Well serving 3+ dwelling units ❑ Community Well or Public ❑ Water Storage 4. TYPE OF WASTEWATER DISPOSAL:❑ Private Septic ❑ Private Septic serving 2 dwelling units ❑ Holding Tank ❑ Community Septic or Public Sewer 5. SEPTIC TANK: ❑ Steel ❑® Plastic ❑ Concrete ❑ Fiberglass Age <1 yr - See advisory if steel older than 20 years 6. ABSORPTION FIELD: ❑ AWWTS ❑ Bed ❑ Deep Trench e❑ Wide Trench ❑ Seepage Pit Waiver request for: Expedited review requested: FE -1 Distance: By applying for this entitlement, this property is subject to inspection by municipal On-site staff to verify the accuracy of the information provided. COSA Fee $ 7s + q - Z Waiver Fee $ Date of Payment q rel 2 Z_ Date of Payment COSA # S C- 22-1 q 6.3 Waiver # COSA Application—June 2022 Legal Description: Overlook Estates #2, Lot 7 Parcel ID: 068-041-39 If more than 1 well and/or septic system on lot, provide separate checklist. Structure served by this system A. WELL DATA ❑ Well log is filed with Onsite (or attached) Date drilled 5/14/22 Total depth 445 ft Cased to 161 ft ❑ Sanitary seal is functioning correctly ❑ Wires are properly protected Casing height (above ground) 24 in. Date of flow test for COSA 5/14/22 Static water level at beginning of test 121 ft Comments B. TANK DATA Measured operating fluid level in septic tank NEW Date of pumping NEW ❑ Required maintenance completed, if AWWTS comments: New Installation D. ABSORPTION FIELD DATA Which system tested (date installed) 2/24/22 ❑ ALL standpipes present per record drawing Total measured depth from grade 10/11.7 ft (max) Measured depth to pipe invert from grade 9.5/11.2 ft (min) ❑ N/A — pressurized field. ❑ Per record drawings, field is insulated. ❑ Monitor tubes go to bottom of effective. If not, state depth into effective ❑ Presoaked required if (Required if house vacant or field not used for more than 30 days prior to date of test) Gallons introduced N/A gallons N/A date Any rejuvenation treatment (past 12 months) N/A If yes, enter date Comments/Deficien COSA Checklist June 2022 Well production at time of test 0.7 gpm Water storage tank volume N/A gallons Well disinfected for coliform test? ❑ Yes ❑ No ❑ Coliform bacteria is Negative Nitrate 2.058 mg/L ❑ Nitrate less than MRL (ND) Arsenic 2.50 ug/L ❑ Arsenic less than MRL (ND) Collected by Wheaton Water Well Date 9/21/22 C. LIFT STATION ired maintenance completed Age of lift station years Lift station material Comments: Adequacy test date NEW Results [:] Pass id depth prior to test in Wate dded gal New fluid th in Elapsed time min Final fluid depth in Absorption rate d FIELD STATUS — POST RE VERY Effective depth (per record drawi ) Effective depth used in Effective depth remaining in in E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well on lot) Septic Tank/Lift Station on Lot > 100' Community Sewer Manhole/Cleanout > 100' QYes if No ft DYes if No ft Neighboring Tank > 100' Yes if No ft Private Sewer/Septic Line > 25' ❑ Yes if No ft Absorption Field on Lot > 100' Q Yes if No ft Holding Tank > 100' ME Yes if No ft Neighboring Absorption Fields > 100' Animal Containment > 50' Q Yes if No ft R Yes if No ft Manure/Animal Excreta Storage > 100' Community Sewer Main > 75' Yes if No ft Q Yes if No ft ❑ N/A — Served by Community Well (not on lot) or Public Water From Septic/Holding Tank and Absorption Field(s) on Lot to: (Please enter distances if less than required) Building Foundations > 10' 0 Yes if No ft Surface Water > 100' 0 Yes if No ft Tank to Property Line > 5' g Yes if No ft Wells on Adjacent Lots: Field to Property Line > 10' Q Yes if No ft Private Wells > 100' 0 Yes if No ft Water Main > 10' Q Yes if No ft Community Wells > 200' m Yes if No ft Water Service Line > 10' 0 Yes if No ft If tank or field is under driveway comment below F. ENGINEER'S COMMENTS G. CERTIFICATION & STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines, indicates that the on-site water supply and/or wastewater disposal system appears to comply with applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation, unless noted otherwise. Name of Firm Forge Engineering Phone (907) 522-7773 Engineer's Printed Name Benjamin Schiller, P. E. Date 9/15/22 gww,.oF AL`s *. TH .1 . , A� • • . Benja jrnr Schiller CE 12592 ��4k- 4FESS14NP�-® COSA Checklist—June 2022 �� �pROFESS0®, Municipality of Anchorage Development Services Department Building Safety Division F r T Y On -Site Water and Wastewater Program 4700 Elmore Street P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 Water Well Advisory Certificate of On -Site Systems Approval (COSA) # OSC221463 During a recent COSA on-site inspection and test of the potable water supply well on Lot 7 of Overlook Estates #2 subdivision, the well's productivity was determined to be .7 gallons per minute. The minimum well productivity required by this Department (AMC 15.55) for a 4 -bedroom residence is .42 gallons per minute. Although the subject well currently exceeds this minimum requirement, all parties concerned are advised that the production capacity of the well may fluctuate. Restriction of non-critical water uses such as washing cars and watering lawns and gardens may be required. This advisory must be attached to all copies of the subject Certificate of On - Site Systems Approval.