HomeMy WebLinkAboutRIVER HILLS ESTATES S12582 & S12668Onsite File River Hills Estates #S12582 #S12668 S12668 - Septic Reserved area for former Lot 2 is eliminated, reserved area for Lot 2A is same as former Lot 3 ENG IN E E R I NG, LLC PHYSICAL MAILING OFFICE WEB 1300 E. 68th Ave., Suite" 210 P.O. Box 111989 907-344-3114 triadak.com Anchorage, AK 99518 Anchorage, AK 99511 March 9th, 2021 Municipality of Anchorage Development Services 4700 Elmore Rd. Anchorage, Alaska 99507 Attention: Deb Wockenfuss, MOA On -Site Subject: River Hills Estates Subdivision Suitability for On -Site Systems Platting Case 512582 Ms. Wockenfuss, The following report details the feasibility of the River Hills Estates Subdivision to support on-site water and wastewater systems for residential single-family homes. The preliminary plat is attached with this report. The site is located in the Hillside area of Anchorage Alaska, south of Rabbit Creek Road, north of E 156th Ave, with vehicular access from Snow Flake Drive. See below for a location map. Location Map a r- 5 R_ 4 Ik1' S o 1 q 3 2 Rov er Su divisio _ .._... 2 1 - it Est I Mo ntain BIk 4 Subd vision 3 Q�a 1 O� S"e Ffake D, J� r , JAoun ain it Esta es ddn N Gudveina Sub vision <<ttle Rabb 1 2 3 bdiv ston S, 1 Adn No it ._ - dCreek =._ .- _. 4 I f. _ Subject - Property Tract F-1 L 6 4 N E 1561'' Ave _ C,5s,,A� Location Map March 911, 2021 Subject: River Hills Estates Subdivision—SuitabilityforOn-Site Systems Platting Case 512582 Page 2 of 4 The parcel is approximately 20 acres in size, split -zoned R6 north of Rabbit Creek and R9 to the south. Based on the zoning and current code, the R6 portion is being subdivided into 6 single-family lots and the R9 portion is to remain an undeveloped tract. The site is bordered by Gudveina Subdivision to the west, Rovier Subdivision to the north, Mountain -Air Subdivision to the east, and E 156`h Ave to the south. The majority of the surrounding lots are developed with residential single-family homes equipped with on-site water and wastewater systems. Water Availability Data from the MOA On-site department indicates the production of existing wells in the area range from 5 to 15 GPM with an average rate of 8 GPM. The depth of wells ranges from 81 to 139 feet with an average static water level of 40 feet below ground surface. See below for a table of the well depths and production rates for the wells surrounding the subject parcel. Surrounding Well Data Subdivision Lot Well Depth (ft) Static Water Level (BGS) Production (GPM) Gudveina 6 Undeveloped Gudveina 7 127 42 5.5 Gudveina 1 Unknown Unknown Unknown Rovier, Block 1 2 1 Undeveloped Rovier, Block 1 3 117 37 5 Rovier, Block 1 4 Unknown Unknown Unknown Rovier, Block 1 5 123 Unknown 10 Rovier, Block 1 6 81 40 6.5 Mountain Air Estates, Block 4 2 116 60 5 Mountain Air Estates, Block 4 3 139 Unknown 15 Mountain Air Estates, Block 7 1 118 38 15 Mountain Air Estates, Block 7 2 100 20 15 Future wells for River Hills Subdivision are anticipated to have similar performance with an average anticipated depth of 120 feet and a production ranging from 5 to 15 GPM. Individual wells are anticipated to be adequate for the subject property if it is developed as proposed with the preliminary plat configuration. The development of this subdivision is not anticipated to have any negative affect on the water availability of the surrounding subdivision or properties. Soils and Septic System Information Test holes were excavated on each of the proposed lots. Native sands and gravels with varying silt content were found throughout the site. A geotechnical report and test hole logs are attached with this report. Percolation testing was performed for each lot. See below for a table showing the percolation results. 2 March 91", 2021 Subject: River Hills Estates Subdivision—SuitabilityforOn-Site Systems Platting Case 512582 Page 3 of 4 Perc Testing - September 2020 Lot Perc Rate (min/inch) Testing Depth (BGS) 1 <1 5-6 ft 2 4.55 mi 4-5 ft 3 <1 3-4 ft 4 <1 4-5 ft 5 <1 3-4 ft 6 125 4-5 ft The perc test for Lot 6 was done within a thin silt tense and is not representative of the general subsurface profile across the site. An additional test hole and perc test on Lot 6 will be completed during the subdivision improvements. All lots are suitable for on-site wastewater disposal systems. Development of the individual lots will require an engineered plan for well and septic locations that will be reviewed and approved by MOA On-site to ensure that the septic tanks and absorption fields are placed outside of the existing and proposed well radii. Nitrate Analysis No existing wells within 250 feet of the proposed subdivision have known nitrate levels exceeding 5 mg/I. See below for a screen capture of nitrate values from the MOA GIS mapper. Nitrate Values — Screen Capture 3/10/21 3 March 911, 2021 Subject: River Hills Estates Subdivision—SuitabilityforOn-Site Systems Platting Case 512582 Page 4 of 4 Due to separation distance restrictions from steep slopes, advanced water and wastewater treatment systems will be required for all lots. Drainage The soils within the area are well-suited to infiltrate runoff and the large lot -sizes stipulated by the R6 zoning helps to ensure that the ratio of impervious area to vegetated area remains low. An engineered grading and drainage plan is being reviewed by MOA Private Development as part of the Subdivision Agreement process. Drainage generated by this development is handled on-site and is not anticipated to have any negative affects to neighboring properties. Conclusion The subject property and the associated preliminary plat is well-suited for on-site water and wastewater systems. Well and septic information from the immediate vicinity of the parcel indicate that aquifer production is adequate for single family homes; the soils are well -draining and will support septic systems. Thank you for your time and consideration in this matter. If you require additional information, please call 907-720-6128 or email me at grantmathews@triadak.com. Sincerely, Triad Engineering, LLC l Grant Mathews, P.E. Attachments On Site Systems Grading Plan Geotechnical Report — Northern Geotechnical Engineering Perc Tests — Northern Geotechnical Engineering 0 ��P• ' f- .• 49 TH t .* GRANT W. MATHEWS ��sTF�• CE 135444 Ap W`PpROFESS0 April 91", 2021 512582 River Hills Estates On -Site Comment Response Letter 1. Show the septic area for Rovier Lot 6 to the north. I have beeii unable to iind reliable information to site the exisnri,g well anid _.eptic on, the el i i l � �„ ,, ll �. ? r �t � _ £I i`1Cte'if�, C3i)�t� �fJt, i � ic<�!-w ..�.C)�.cil _ �� the 1 1Gu t�C'a[i�i€i Qri ,Cit i] 1Ci ,kt.i E?titur(3k:.C�1 E)VitC.? I%oV3er Lot 6. 2. Per soil log submitted, Lot 6 is not developable. My understanding is that new soils testing will be completed soon. 'tCit,e1.E:?#?a. �_.�� {1i...t.. �I+� i..�"t., i ,r. ,�ci,3 t:a?i.tlJletf'a �Ji" , ipr?( �. f x(.1',.'_1.. See uti:SC'I`1vG .�? ie.i� cis"a( 3. The designed systems are not within 30' of a testhole. i.ie s its Y +;lation rates, are i"? )rtiogeitous across the iie 4. Add slope arrows to the slope(s) created by the proposed road. 5. Add the engineers seal to the calculations. 6. The calculations for the 5 -wide design is incorrect. Revised. 7. A sand liner is required for the fast, gravelly soil found. Only 6" of sewer rock beneath the distribution pipe can be used with a sand liner. When redesigning, make sure the trenches are parallel to the contours. The bottom of the trenches must meet the required vertical separations to water and impermeable layers. The silt strata found in some testholes may be impermeable. tt,Evise-_vas itrcorrao;a.L.d i,to the revised Ir,alct,lai?c,;7s (nc, reduction fac•trar £arc=.). it: icls are . a idle; to the contours. A4.:Cordin,1,, to Northern C_�:-`c-eC:l'nicall c f1 x €1e ring, E`?!J i111(s �/ i� r r e ,c r i t �;t a�e�i fiCl Cj�P 3 s, � r __ �31t fa £Y i�,£,�i, i xz.t=6 i i_U€ t'.., 1�,I�ii "1Si a £tv.li ✓e. : ?t ve zhe i,)ott,orri of the prolposed Irerich, design ign 8. The first note shall state "Cat III Advanced Wastewater Treatment Systems" Prrc)poseci j,iat notes: Lots u, 2, , +' and 6 skill requireCat III Advanced '.lhistet>ate 3 it citment a��%`�teni i !. tries` oth tsvise. JI n'.it l d by . e AAOA On ` e `ief, a eflien . TO ,:kll; bekomp cmmt tr or 1, _, 3, cvEx ushall he linked u.1 5 NEw`i?o,T;s. The areas lor drain h ids, X111 i. C?ts _j, 2, 3, and 6 shall not be use'_<:< for ytnuct`,l,:res, !"E -r (:zis t'JUc7y5, or pe3'141E1,, 1E as unless an aItt.ii'i<li?lf-` crpilC stj.: ?iil di-3<ilgli is submitted t to E".Iid approved by the ( IOA Chi Site EreparkneM, Design Calculations for Drain Field Sizing for Lots 1, 2, 3, and 6: Perc Rate (measured) = 1-5 min/inch Category III Advanced Wastewater Treatment System Application Rate = 6 gpd/sf Max Bedroom Count = 5 5 x 150 gpd/bdrm = 750 gpd 750 gpd / 6 gpd/sf = 125 sf 5 -wide trench w/ 4 -ft effective depth 1251/5ft=25 ft *No reduction factor for 5 -wide with sand liner. 25 linear ft trench provided Grant Mathews, P.E. 0F, A *:•49a M � • WANT VI.MATHEWS 9P •• CE 13544401. g, ����®��PROfESS10�aP�,o.� AW SEPT 2020 SOILS INVESTIGATION NORTHERN GEOTECHNICAL ENGINEERING RIVER HILLS ESTATES SUBDIVISION LOT HDEPTH TO GW PERC RATE 1 NGWE <1 MIN/INCH 2 NGWE 4.55 MIN/INCH 3 7.45' <1 MIN/INCH 4 NGWE <1 MIN/INCH 5 NGWE <1 MIN/INCH 6 9.03' 125 MIN/INCH NOTE AN ADDITIONAL TEST HOLE AND PERC TEST WLL BE CDMPIETED FOR LOT B. - I\ BRIT GRE J `0 A I 1 — RAS03 51 D\J\5\100 �0 / A -S GOOD P00`� P� S6 PL 7 0 I I 1 I t a '4ZI iAREA 10 l I. \ 3 i SEE DETAILQA SHEET C5 tprinu I 1, ( �6' %- FOR CULVERT DETAIL ''_I:_ _ DR —APPROX LIMITS OF CLEARING & GRUBBING i I EX BLOC a E BCD 0 \Ota �� I I I I I I � I I I I I I I I I SUBDIVISION AGREEMENT NUMBER 21-002 1. DATA PROVIDED BY This will serve to certify loot hese Recore Drowi'& ea true and occurole PreaenteGon or the project - constructed. CONTRACTOR: nnE: _DATE: -- 2. DATA TRANSFERRED BY: _ COMPANY: RAIL: __ _ 1 DATA TRANSFER CHECKED Boned on peri.Q:. field ob- wlions by the Engineer (w on individuol ureer hia/ her direct supervision), the Conlroclor-provided do to oppeersto const—ted. resent the Is project Wcled. BY: COMPANY: bT: Q In W < U Q W W U) J c;6 V) cO � N bi > �-- z E0 O W 3 _ O � W a =!2 :> h = O 0-I In U SHEET 1 °` 1 c -E. . P T,r I LOT 6 CONTAINS AN EXISTING _ I I WELL AND SEPTIC SYSTEM. — _ _ _ _ —( \`\ ( \\ I I I EXACT LOCATION UNKNOWN. I I 10' T&E ESMT \\ ( I 10' T&E ESL(T II D\J\5\100 �0 / A -S GOOD P00`� P� S6 PL 7 0 I I 1 I t a '4ZI iAREA 10 l I. \ 3 i SEE DETAILQA SHEET C5 tprinu I 1, ( �6' %- FOR CULVERT DETAIL ''_I:_ _ DR —APPROX LIMITS OF CLEARING & GRUBBING i I EX BLOC a E BCD 0 \Ota �� I I I I I I � I I I I I I I I I SUBDIVISION AGREEMENT NUMBER 21-002 1. DATA PROVIDED BY This will serve to certify loot hese Recore Drowi'& ea true and occurole PreaenteGon or the project - constructed. CONTRACTOR: nnE: _DATE: -- 2. DATA TRANSFERRED BY: _ COMPANY: RAIL: __ _ 1 DATA TRANSFER CHECKED Boned on peri.Q:. field ob- wlions by the Engineer (w on individuol ureer hia/ her direct supervision), the Conlroclor-provided do to oppeersto const—ted. resent the Is project Wcled. BY: COMPANY: bT: Q In W < U Q W W U) J c;6 V) cO � N bi > �-- z E0 O W 3 _ O � W a =!2 :> h = O 0-I In U SHEET 1 °` 1 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Section - 4700 Elmore St. P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.orq/onsite (907)343-7904 Performed For: Legal Description TP2 Soils Log - Percolation Test TRIAD ENGINEERING, LLC Date Performed: 9/9/2020 E1/2, SE1/4, SWI/4 Township, Range, Section: T12N, R3W, SEC 35 49 y .. C4 tarGs.6�aiaha[ _ � i g C9Y 1485$ 10- 11- 12- 13- 14- 15- 16- 17- 18- 19- 20 - BOH @ 12.0 FT Site Plan WAS GROUND WATEF (Feet) ENCOUNTERED? ENCOUNTERED Depth to Water ORGANIC MAT 1 - L Depth to Water After 0 NOT P Monitoring? ORGANIC SILT 2- ON Date: 3- 68.41" 9/22/20 3 10/30/20 GRAVEL 4- 68.41" 6" 4 9/9/2020 SILT 5- 68.41" 6„ 6- 9/9/2020 GRAVEL WITH SILT <1 MIN. 68.41" AND SAND WITH 7- 9/9/2020 COBBLES AND <1 MIN. 68.41" TRACE BOULDERS 8- 9- 10- 11- 12- 13- 14- 15- 16- 17- 18- 19- 20 - BOH @ 12.0 FT Site Plan WAS GROUND WATEF NOT ENCOUNTERED? ENCOUNTERED Depth to Water s IF YES, AT WHAT DEPTH? L Depth to Water After 0 NOT P Monitoring? ENCOUNTERED E 2 ON Date: 9/9/20 68.41" 9/22/20 3 10/30/20 Reading Date Gross Time Net Time Depth to Water Net Drop 1 9/9/2020 2 MIN <1 MIN. 68.41" 6" 2 9/9/2020 3 MIN <1 MIN. 68.41" 6" 3 9/9/2020 4 MIN <1 MIN. 68.41" 6" 4 9/9/2020 5 MIN <1 MIN. 68.41" 6„ 5 9/9/2020 6 MIN <1 MIN. 68.41" 6" 6 9/9/2020 7 MIN <1 MIN. 68.41" 6" PERCOLATION RATE <1 (minutes/inch) PERC HOLE DIAMETER 3" PIPE DIAMETER TEST RUN BETWEEN 5.201 FT AND 5.701 FT COMMENTS THE INFILTRATION TEST WAS PREFORMED IN GENERAL CONFORMANCE WITH THE FALLING HEAD PERCOLATION TEST PROCEDURE OUTLINED IN TABLE 3.9 OF THE EPA ON-SITE EATER TREATMENT & DISPOSAL SYSTEMES MANUAL. 12" OF WATER DRAINED AWAY IN LESS THAN 30 MIN. TWICE SO TEST WAS STARTED. PERFORMED BY: CLINTON BANZHAF I SEE NOTE ABOVE CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: 1/11/2021 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Section - 4700 Elmore St. P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907)343-7904 Performed For: Legal Description: 1- 2- 3- 4- 5- 6- 7- 8- 9- 10- 11- 12- 13- 14- 15- 16- 17- 18- 19- 20- TP3 Soils Log - Percolation Test TRIAD ENGINEERING, LLC Date Performed: 9/9/2020 E1/2, SEI/4, SW1/4 Township, Range, Section: T12N, R3W, SEC 35 49 4 OCM,on J. Banzhaf / �¢{ f G 14856 �1rl,,ll tsw� ORGANIC MAT ORGANIC SILT GRAVEL WITH SILT AND SAND WITH COBBLES AND TRACE BOULDERS BOH @ 8.0 FT FW WAS GROUND WATER NOT Gross Time ENCOUNTERED? ENCOUNTERED Net Drop 1 9/9/2020 s IF YES, AT WHAT DEPTH? 56.56" L Depth to Water After NOT O P Monitoring? ENCOUNTERED E 3 ON 79 MIN Date: 9/9/20 4.29" 4 9/22/20 89 MIN 10 MIN. 10/30/20 3.62" Site Plan Reading Date Gross Time Net Time Depth to Water Net Drop 1 9/9/2020 59 MIN 10 MIN. 56.56" 7.24" 2 9/9/2020 69 MIN 10 MIN. 54.14" 4.82" 3 9/9/2020 79 MIN 10 MIN. 53.61" 4.29" 4 9/9/2020 89 MIN 10 MIN. 52.94" 3.62" 5 9/9/2020 99 MIN 10 MIN. 51.73" 2.41" 6 9/9/2020 109 MIN 10 MIN. 1 51.55" 1 2.23" Ht:KL;ULAI IUN RHI -E v.00 (minutes/inch) PERC HOLE DIAMETER 3" PIPE DIAMETER TEST RUN BETWEEN 4902 FT AND 5.402 FT COMMENTS THE INFILTRATION TEST WAS PREFORMED IN GENERAL CONFORMANCE WITH THE FALLING HEAD PERCOLATION TEST PROCEDURE OUTLINED IN TABLE 3.9 OF THE EPA ON-SITE EATER TREATMENT & DISPOSAL SYSTEMES MANUAL. 12" OF WATER DRAINED AWAY IN LESS THAN 30 MIN. TWICE SO TEST WAS STARTED. PERFORMED BY: CLINTON BANZHAF / SHAE MURPHY SEE NOTE ABOVE CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: 1/11/2021 Performed For: Legal Description 1- 2- 3- 4- 5- 6- 7- 9- 10- 11- 12- 13- 14- 15- 16- 17- 18- 19- 20- Municipality of Anchorage Development Services Department On -Site Water and Wastewater Section 4700 Elmore St. P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907)343-7904 Soils Log - Percolation Test 9.49 ► Cr ntonJ.Banahaf TRIAD ENGINEERING, LLC Date Performed: 9/9/2020 E1/2, SE1/4, SW1/4 Township, Range, Section: T12N, R3W, SEC 35 Slooe Site Plan Depth TP4 (Feet) ORGANIC MAT ORGANIC SILT GRAVEL SILT GRAVEL WITH SILT AND SAND WITH COBBLES AND TRACE BOULDERS BOH @ 8.0 FT „251 4° 407 W 7 P,B: rras7rs x¢1'",sat�ao�T rasa « TP4 }3P2 3 r rtisa� �s� � -• F � r` k ...� WAS GROUND WATEI YES ENCOUNTERED? S IF YES, AT WHAT DEPTH? 7.532' ON 9/9120 L Depth to Water After O P Monitoring? 7.612' ON 10/30/20 E DatE 10/30/20 Reading Date Gross Time Net Time Depth to Water Net Drop 1 9/9/2020 6 MIN <1 MIN. 45.37" 6" 2 9/9/2020 8 MIN <1 MIN. 45.37" 6" 3 9/9/2020 10 MIN <1 MIN. 45.37" 6" 4 9/9/2020 13 MIN <1 MIN. 45.37" 6" 5 9/9/2020 16 MIN <1 MIN. 45.37" 6" 6 9/9/2020 19 MIN <1 MIN. 45.37" 6" PERCOLATION RATE <1 (minuteslinch) PERC HOLE DIAMETER 3" PIPE DIAMETER TEST RUN BETWEEN 3.281 FT AND 3.781 FT COMMENTS THE INFILTRATION TEST WAS PREFORMED IN GENERAL CONFORMANCE WITH THE FALLING HEAD PERCOLATION TEST PROCEDURE OUTLINED IN TABLE 3.9 OF THE EPA ON-SITE EATER TREATMENT & DISPOSAL SYSTEMES MANUAL. 12" OF WATER DRAINED AWAY IN LESS THAN 30 MIN. TWICE SO TEST WAS STARTED. PERFORMED BY CLINTON BANZHAF/SHAE MURPHY I SEE NOTE ABOVE CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: 1/11/2021 Performed For: Legal Description: 1- 2- 3- 4- 5- 6- 7- 8- 9- 10- 11- 12- 13- 14- 15- 16- 17- 18- 19- 20 - Municipality of Anchorage Development Services Department On -Site Water and Wastewater Section 4700 Elmore St. P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907)343-7904 Soils Log - Percolation Test TRIAD ENGINEERING, LLC Date Performed: 9/9/2020 E1/2, SE1/4, SW1/4 Township, Range, Section: T12N, R3W, SEC 35 Aw 4 TH i . . c- 3, . . t wiinion.i.B�rt2t:�s Depth TP5 (Feet) ORGANIC MAT ORGANIC SILT GRAVEL SILT GRAVEL WITH SILT AND SAND WITH COBBLES AND TRACE BOULDERS WAS GROUND WATEI NOT Gross Time ENCOUNTERED? ENCOUNTERED Net Drop BOH @9.5FT 9/9/2020 s IF YES, AT WHAT DEPTH? NOT L Depth to Water After ENCOUNTERED O Monitoring? ON 9/2/20 p E 6" 9/9120 9/9/2020 Date: 10/30/20 53.52" Site Plan TE_6 1J}r 3d J S?4 i '^� ;, !,y '-�: '"��R�f~'r • L'1 '"7GA'M.91� `3r. t 5874&� _ rases o> _ T a¢ "t .: � TF4� -. wt Reading Date Gross Time Net Time Depth to Water Net Drop 1 9/9/2020 2 MIN <1 MIN. 53.52" 6" 2 9/9/2020 2 MIN <1 MIN. 53.52" 6" 3 9/9/2020 3 MIN <1 MIN. 53.52" 6" 4 9/9/2020 3 MIN <1 MIN. 53.52" 6" 5 9/9/2020 4 MIN <1 MIN. 53.52" 6" 6 9/9/2020 4 MIN <1 MIN. 53.52" 6" PERCOLATION RATE <1 (minutes/inch) PERC HOLE DIAMETER 3" PIPE DIAMETER TEST RUN BETWEEN 3.960 FT AND 4.460 FT COMMENTS THE INFILTRATION TEST WAS PREFORMED IN GENERAL CONFORMANCE WITH THE FALLING HEAD PERCOLATION TEST PROCEDURE OUTLINED IN TABLE 3.9 OF THE EPA ON-SITE EATER TREATMENT & DISPOSAL SYSTEMES MANUAL. 12" OF WATER DRAINED AWAY IN LESS THAN 30 MIN. TWICE SO TEST WAS STARTED. PERFORMED BY CLINTON BANZHAF/SHAE MURPHY I SEE NOTE ABOVE CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: 1/11/2021 Performed For: Legal Description Municipality of Anchorage Development Services Department On -Site Water and Wastewater Section 4700 Elmore St. P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.or_q/onsite (907)343-7904 Soils Log - Percolation Test 491H .* I� Clinton J. Banzhaf TRIAD ENGINEERING, LLC Date Performed: 9/9/2020 E1/2, SE1/4, SW1/4 Township, Range, Section: T12N, R3W, SEC 35 Depth TP6 (Feet) ORGANIC MAT 1- 2- ORGANIC SILT 3- 4- 5- 6- 7- 8- 9- 10- 11- 12- 13- 14- 15- 16- 17- 18- 19- 20 - SILTY GRAVEL TO GRAVEL SILT SILTY SAND WITH GRAVEL BOH @ 8.5 FT Rita Plan WAS GROUND WATEI NOT Gross Time ENCOUNTERED? ENCOUNTERED Net Drop 1 9/9/2020 S IF YES, AT WHAT DEPTH? NOT L Depth to Water After ENCOUNTERED O <1 MIN. ON P Monitoring? 9/2/20 E <1 MIN. 9/9/20 6" Date: 10/30/20 3 MIN Reading Date Gross Time Net Time Depth to Water Net Drop 1 9/9/2020 2 MIN <1 MIN. 40.86" 6" 2 9/9/2020 2 MIN <1 MIN. 40.86" 6" 3 9/9/2020 3 MIN <1 MIN. 40.86" 6" 4 9/9/2020 3 MIN <1 MIN. 40.86" 6, 5 9/9/2020 4 MIN <1 MIN. 40.86" 6" 6 9/9/2020 4 MIN <1 MIN. 40.86" 6" F'EKGULA I ]ON RATE <1 (minutes/inch) PERC HOLE DIAMETER 3" PIPE DIAMETER TEST RUN BETWEEN 2.905 FT AND 3.405 FT COMMENTS THE INFILTRATION TEST WAS PREFORMED IN GENERAL CONFORMANCE WITH THE FALLING HEAD PERCOLATION TEST PROCEDURE OUTLINED IN TABLE 3.9 OF THE EPA ON-SITE EATER TREATMENT & DISPOSAL SYSTEMES MANUAL. 12" OF WATER DRAINED AWAY IN LESS THAN 30 MIN. TWICE SO TEST WAS STARTED. PERFORMED BY CLINTON BANZHAF/SHAE MURPHY I SEE NOTE ABOVE CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: 1/11/2021 Performed For: Legal Description Municipality of Anchorage Development Services Department On -Site Water and Wastewater Section 4700 Elmore St. P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.or /oq nsite (907) 343-7904 Soils Log - Percolation Test TRIAD ENGINEERING, LLC Date Performed: 9/9/2020 E1/2, SE1/4, SW1/4 Township, Range; Section: T12N, R3W, SEC 35 Depth TP7 ( Feet) ORGANIC MAT 1- ORGANIC SILT 2- 4- 5- 6- 7- 8- 9- 10- 11- 12- 13- 14- 15- 16- 17- 18- 19- 20 - WELL GRADED GRAVEL WITH SAND AND COBBLES AND TRACE BOULDERS BOH @ 9.1 FT Site Plan WAS GROUND WATEI YES ENCOUNTERED? s IF YES, AT WHAT DEPTH? L Depth to Water After 9.0' ON 912/20 O 9.1' ON 9/9/20 P Monitoring. 8.6' ON10/30/20 E Date: Reading Date Gross Time Net Time Depth to Water Net Drop 1 9/10/2020 30 MIN 30 MIN. 0.24" 0.24" 2 9/10/2020 60 MIN 30 MIN. 0.23" 0.23" 3 9/10/2020 90 MIN 30 MIN. 0.24" 0.24" F'tKGULA I IUN KA I 125.0 (minutes/inch) PERC HOLE DIAMETER 3" PIPE DIAMETER TEST RUN BETWEEN 4.097 FT AND 4.597 FT COMMENTS THE INFILTRATION TEST WAS PREFORMED IN GENERAL CONFORMANCE WITH THE FALLING HEAD PERCOLATION TEST PROCEDURE OUTLINED IN TABLE 3.9 OF THE EPA ON-SITE EATER TREATMENT & DISPOSAL SYSTEMES MANUAL. A 24HR SOAKING PERIOD WAS COMPLETED. PERFORMED BY CLINTON BANZHAF/SHAE MURPHY SEE NOTE ABOVE CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL. GUIDELINES IN EFFECT ON THIS DATE. DATE: 1/11/2021 Performed For: Legal Description: Municipality of Anchorage Development Services Department On -Site Water and Wastewater Section 4700 Elmore St. P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 Soils Log - Percolation Test TRIAD ENGINEERING, LLC Date Performed: 4/7/2021 E1/2, SE1/4, SWI/4 Township, Range, Section: T12N, R3W, SEC 35 (ENGINEER'S SEAL) OF At �Z � . TH F 1k I ''�� GF • i�9�6 ��;� r TP9 (Feet) ORGANIC MAT 1 - ORGANIC SILT 2- 3 - GRAVEL 4- BOH @ 4.5 FT 6- 7- 8- 9- 10- 11- 12- 13- 14- 15- 16- 17- 18- 19- 20 - WAS GROUND WATEF NOT ENCOUNTERED? ENCOUNTERED Depth to Water S IF YES, AT WHAT DEPTH? L Depth to Water After O NOT p Monitoring? ENCOUNTERED E 2 ON Date: 4/7/2021 Site Plan Reading Date Gross Time Net Time Depth to Water Net Drop 1 4/7/2021 2 MIN <1 MIN. 6.00" 6" 2 4/7/2021 3 MIN <1 MIN. 6.00" 6" 3 4/7/2021 4 MIN <1 MIN. 6.00" 6" 4 4/7/2021 5 MIN <1 MIN. 6.00" 6" 5 4/7/2021 6 MIN <1 MIN. 6.00" 6" 6 4/7/2021 7 MIN <1 MIN. 6.00" 6" PERCOLATION RATE <1 (minutes/inch) PERC HOLE DIAMETER 6" TEST RUN BETWEEN 4.000 FT AND 4.500 FT BELOW GROUND SURFACE INITIAL READING TO DETERMINE IF A SOAKING PERIOD IS REQUIRED WAS TAKEN WITH 6" OF WATER IN PIPE (INITIAL WATER DEPTH IS NOT STATED IN MOA CODE). MOA CODE REQUIRES MEASUREMENTS IN 10 MIN. INTERVALS FOR 1 HR. IF THE WATER DRAINS IN LESS THAN 30 MIN, THE WATER DRAINED IN LESS THAN 1 MIN. THEREFORE THE PIPE WAS IMMEDIATELY FILLED AFTER THE 6" OF WATER DRAINED TO PROCEED WITH THE TEST. THE WATER CONTINUED TO DRAIN LESS IN LESS THAN 1 MIN SO 6 MEASUREMENTS/TIMES WERE RECORDED TO PROVIDE A REPRESENTATIVE PERCOLATION RATE. THESE VARIATIONS TO THE CODE WERE APPROVED VERBALLY AND BY EMAIL BY DEB WOCKENFUSS PRIOR TO THE TEST. THESE WERE THE ONLY VARIATIONS TO THE MOA TEST PROCEDURE. PERFORMED BY: SHEA MURPHY I SEE NOTE ABOVE CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: 4/9/2021