HomeMy WebLinkAboutUS SURVEY 3042 LT 3 T10N R2E SEC 19Onsite File
Ub'A' SumAhr&mndvkAey 3042
�� t
N
Lot 2A
a
LEGEND'
Sewer Manhole
Al, Comm. Pedestal
Utility Pole
Well
Overhead Utilities
If
Proposed Asphalt
Driveway
Proposed Edge of Asphalt U , S \,., (t- G', i e i -
NOTES t__07-- 3
0
Unit 6
Unit 7
IEL Cu 3
Lot 2C 1 �J
C
-All dimensions shown are grid bearings and ground distances.
-49th Star has conducted a physical survey of the property and all details shown on this Asbuilt Sun�ey are correct.
-It is the o"mers responsibility to determine the existence of any easements, covenants, or restrictions which do not appear
on the recorded US Survey subdivision plat.
Lot 3
S 304
1
Certified Drilling Log
P Doc CO dba
BILL & COLE
�0-o-ALIUANWATERWELLS
"'� ' RO. Box 670269, Chugiak, AK 99567 688-2759
OWNER OF LAND: MGJ Building Group
ADDRESS:
LEGAL DESCRIPTION US SURVEY 3042 L3 T10N R2E
Sec19
DATE: 2-15-22
Bore Hole
Data
Depth
From
To
PERMIT OSP221030 DATE OF ISSUE:2-14-22
NUMBER:
TAX IDENTIFICATION 075-132-05
NUMBER
Is well located at approved permit location: ®Yes ❑No
Method of Drilling: ®air rotary Rcable tool
Depth of Well: 105'
Casing Type: Steel Wall thickness .250 inches
Diameter: 6 inches, depth 105 feet
Liner type
0
2
Casing Stickup
2
5
Overburden
5
24
Hardpan & Cobbles
24
38
Silty Sand & Gravel
38
71
Loose Sand & Gravel w/ Cobbles
71
86
Silty Sand & Gravel
86
91
Sand & Gravel Water 8 GPM
Static Water Level: 75 feet
Recovery Rate 20 0—gpm gph
Method of Testing Air
Well Intake Opening Type: ® open end ❑open hole
❑ Screened Start feet Stopped
❑ Perforations Start feet Stopped
Grout Type: Bentonite Volume: 100lbs
Depth: from 2 feet, to 42 feet
Well Disinfected Upon Completion: ®yes ❑ no
Method of Disinfection: Chlorine 50 PPM
Comments:
Well #1- Duplex
91
105
Sand & Gravel Water 20 GPM
Drillers
Name:
Cole Sullivan
ATTENTION: It is the responsibility of the property owner to submit a copy of the well log to the proper authority. Municipality
of Anchorage: Department of Health & Human Services and/or Department of Environmental Conservation. Matsu Borough:
Department of Environmental Conservation.
Q BILL & COL Doc co dba
:qh ULLIVAN WATER WELLS
*' RO. Box 670269, Chugiak, AK 99567 688-27591
www.suilivanwaterwells.com
Pump Installation Log
Well Drilling Permit Number: SW OSP221030 Date of Issue 2-14-22
Parcel Identification Number: 075-132-05
Legal Description
US Survey 3042 L3 T10N R2E Sec 19
I Pump Installation Date: 9-14-22
H Pump Intake Depth Below Top of Well Casing: 90
I Pump manufacturer's Name: Franklin
11 Pump Model: 10FRD1P4-3W230
I Pump Size: 1
11 Pitless Adapter Burial Depth: 10
Pitless Adapter Installer: Bolinder Excavation
Disinfected Upon Completion? ® yes ❑ no
Method of Disinfection: Chlorine 50 PPM
Comments: Pitless Manufacturer Martinson
NOTE; Well#1= DuOer
H Pump Installers Name: Sullivan Water Wells
Property Owner Name & Address
MG1
feet
M
feet
Attention: The pump installer shall provide a pump installation log to the DSD within 30 days of pump installation.
M =I
Sewer Manh6le
Comm. Pedestal
utility Pole
Wa
Overhead Utilities
Proposed Edge of Asphalt
'Star
surve 1, ying
0 20 40
US SURI-VEY
FEFr
2nd F1r. Deck
2931
8.0#
Toumhome Footprint (Scale: 1 20)
-All dimensions sho-*,vn are grid bearings and ground distances.
-49th Star has conducted a physical survey of the property and aU details shown on this Asbuilt Sim7ey are correct.
I
-It is the ourners responsibility to determme the existence of any easements, covenants, or restrictions which do not appear
on the recorded US Survey subdivision plat.
I
W.O. 1:903 3 DATE 1/26/23
1 SCAIR 1"-40'
00,
PLAN
0 20 40 80
Scale in Feet
1;r4
9
7
Sewer Line As—Built PROFILE
Station
1+.00
STA 2+21
z
Table
CLEANOUT LOCATION STA 1+25.3
0
Easting
Description
CIPNOUT LOCATION
So *0 00 0 0 as
STA 1+05.4
1788291.65
SEWER CLEANOUT
*I
/yl�+
)
CLEANOUT LOCA11C N
1788260.28
mmm mom
10 GRADE BREAK STA 2+18.37
0
1788231.70
MMlmmm
STA 1+25.3
0 •
1788213.72
z
��Mlmm
2539009-46
1788128.15
0
DESIGN SEWER LINE LOCATION
FINISHED GE
RAD
M=lmmm
mmO=I
SURVEYED 10/10/22
...........................................................
•
•
--- - -------- 9,5. 09. -------------
---------- ------
... ... . .... jl 0 ------------ -------
0
0
54%
AS—BUILT SEWER LINE LOCATION
51 .53, 08.68%
0i
06
GRADE BREAK STA = 1+23.32
- ---- 66.3 _ ------
0 5 27%
0 5.2 7%
ELEV = 76.330
6
---------- ---------- ------- -- ---------- ----- -- ---
- - ------------ -- ----- - -- ---------
5.59' 9, 0
0 4.48X
--- -------- - ------ -------
GRADE BREAK STA =
0+00.11
ELEV =
68.129
Nflummommmme]
HORIZONTAL SCALE
0 15 30 60
Scale in Feet
1+*00
vER,nCAL SCALE 0-�0111
0 7.5 15 30
Scale in Feet
NOTES
#1 BASIS OF ELEVA11ON IS TBM 605, A FOUND SPIKE IN SPRUCE
TREE N: 2539111.164 E: 1788361.441 EL.=74.86' .
#2 COORDINATES ARE NAD83 ALASKA STATE PLANE ZONE 4.
#2 DATE OF SURVEY 6/11/22, 6/2/22, 6/6/22 & 10/10/22.
LEGEND
AS -BUILT SEWER LINE SEWER CLEANOUT
DESIGNED SEWER LINE
EXISTING SEWER LINE
100' WELL RADIUS
Point
Table
Stationing
Northing
Easting
Description
STA 0+18.3
2538891.16
1788291.65
SEWER CLEANOUT
STA 0+84.3
2538948.19
1788260.28
mmm mom
STA 1+05.4
mm
1788231.70
MMlmmm
STA 1+25.3
2538969.16
1788213.72
MINIM
��Mlmm
2539009-46
1788128.15
MWINNIM
—0
M=lmmm
mmO=I
mmm
LEGEND
AS -BUILT SEWER LINE SEWER CLEANOUT
DESIGNED SEWER LINE
EXISTING SEWER LINE
100' WELL RADIUS
OF 'fit �
fit
H
jo, *A— Pie M. 5 r
N LS- 12 too
1/19/2023
low
WW
Ss* Iot4��
144tkW***1*1
WN
IC
N
ra
X
A
RUM
NMI S. SIR OEM POWDER RIDGE DEVELOPMENT
US SURVEY 3042; LOT 3 T10N R2E SEC. 19
CW1 P. STRAGIER
SEWER LINE AS—BUILT
17777my
FS 22-017
Point
Table
Stationing
Northing
Easting
Description
STA 0+18.3
2538891.16
1788291.65
SEWER CLEANOUT
STA 0+84.3
2538948.19
1788260.28
SEWER CLEANOUT
STA 1+05.4
2538960.59
1788231.70
SEWER CLEANOUT
STA 1+25.3
2538969.16
1788213.72
SEWER CLEANOUT
STA 2+21
2539009-46
1788128.15
SEWER CLEANOUT
OF 'fit �
fit
H
jo, *A— Pie M. 5 r
N LS- 12 too
1/19/2023
low
WW
Ss* Iot4��
144tkW***1*1
WN
IC
N
ra
X
A
RUM
NMI S. SIR OEM POWDER RIDGE DEVELOPMENT
US SURVEY 3042; LOT 3 T10N R2E SEC. 19
CW1 P. STRAGIER
SEWER LINE AS—BUILT
17777my
FS 22-017
MUNICIPALITY OF ANCHORAGE
On -Site Water & Wastewater Program
PO Box 196650 4700 Elmore Road
Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997
http://www.muni.org/onsite
On -Site !Nater System Permit
Permit Number: OSP221030
Work Type: Well Initial
Tax Code Number:
Site Legal Address: US SURVEY 3042 LT 3 T10N R2E SEC 19 G:5012
Site Mailing Address:
Owner:
Design Engineer: GARNESS ENGINEERING GROUP LTD
Effective Date:
Expiration Date:
Lot Size in Sq Ft
Total Bedrooms
.S'
Departinent
2/14/2022
2/14/2023
65340
This permit is for the construction of:
❑ Disposal Field ❑ Septic Tank ❑ Holding Tank ❑ Privy Q Private Well ❑ Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
Received
Issued By:
Date: t
Date: _
R
MUNICIPALITY OF ANCHORAGE
Development Services Department Phone: 907-343-7904
On -Site Water & Wastewater Section �='` Fax: 907-343-7997
ON-SITE SEPTIC/WELL PERMIT APPLICATION
Parcel I.D.rd- 075-132-05
Property owner(s) JMG BUILDING GROUP Day phone 907-306-9145
Mailing address NHN GUNNYSACK MINE ROAD *GIRDWOOD, AK
Site address
Legal description (Sub'd., Block & Lot) US SURVEY 3042; LOT 3
Legal description (Township, Range & Section)
Lot Size Sq. Ft. Number of Bedrooms 6
APPLICATION IS FOR:
(® all that apply)
Upgrade ..
Absorption Field
Renewal
Septic Tank
❑
Holding Tank
❑
Privy
❑
Private Well
Water Storage
❑
APPLICATION IS AN:
Initial
0
Upgrade ..
❑
Renewal
❑
THIS APPLICATION INCLUDES A WAIVER REQUEST FOR:
TYPE OF DWELLING:
Single Family (SF)
(w/wo ADU)
Duplex (D)
Multiple Dwellings
(SF and/or D)
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
of property owner or auth ized agent)
Permit/Rush Fees: $2 2- S Waiver Fees:
Date of Payment: v2 z.Z Date of Payment:
Receipt Number: 0 0 0 I G Receipt Number:
Permit No. (bpa 2 /03D Waiver No.
GADevelopment Services\Building Safety\On Site Water and WastewaterlForms\Client FormsTermit Application.doc
01
VICINITY MAP
ANCHORAGE, ALASKA
SHEET INDEX
SHEET NUMBER
SUBJECT
1
COVER SHEET AND NOTES
2
SEWER SERVICE PLANS
DESIGN DRAWINGS
THIS PROJECT
BASED UPON AWWU'S INTERPRETATION OF THF
DESIGN ENGINEER'S INTENT, THIS PLAN APPROVAL
IS TO ENSURE THAT THE PLANS WERE DESIGNED TO
AWWU'S STANDARDS AND THE SIGNEE IS NOT
LIABLE FOR ANY ERRORS OR OMISSIONS.
APPROVED FOR CONSTRUCTION
By Anchorage Waters & Wastewater Utility
Date 7- Z- Zo By
LEGEND - PLAN
ENS77NP PROPOSED DEMWPnaV
PRO-orY LUIS
--- -- EASEW91r
-- aNIDItWE
--- CEM ! CI r7ER
EDGE OF PAWagNr
- W - - W- WArcR MAW
B - - $ - SEALR MAN
- SO - -SO- SMW DRAW MAW
-DEF— -Qp- OVEDE40 ELECTRIC
-O/R- --OHp.. OVEINEAO 7aDW00WE
E - - £ - LMERCRDUND aEC7RIC
C - - C - LWOFRGRO-wo CADLE
- T-- T- UAV-MGMM M R2ZWWC V
ONCERCRO" NATURAL CAS
- - + - FENCE
CALL BEFORE YOU DIG
The C -L -to hdl ..Ufy W .. utInty —pad.
V- to ----t o1 neo ilm, TAe ldb-Ng
o P=Ud n2L
LOCATE CALL CENTER of ALASKA 278-3121
LRbne cw eO: A� 17i of EHc� Boa- AMo I-
S
MDA Slorm/etrnla)
STATE STORM/STREET LIGHTS 333-2411
MILITARY PETROLEUM LINES
AD - ALGEBRAIC DYTERENCE
AWYAI- ANaiGRAGE WATER d WASTEWATER
BON - BOTIpf OF HOLE
BPP - BOTWU OF PIPE
BV - eurnwEr VALYE
BVCE - WGIN VERUCAL CURVE - EI.EVARON
SVGS - BEGIN VERTICAL CURVE - SIATILW
E7EV - ELEVA RON
EDP - EDC' OF PAtcwDvr
EKE - OW YER17CAL CURVE - ELEVATION
ENS - END VERRG(L LLRVE - SURLW
Fkf - FURNISH AND INSrALL
FC - nN75NED TRADE
HI - VIRE HYDRANT
CV - CAfE VALVE
N- NORIZONrAL
IAW - W ACCORDANCE MIM
WV - NVFRr
K - SGUr OISrANCE
Lr - Corr
LASS- NUN. OF ANOId7ACE SRI SPEDFICA TIONS
MSL - MEAN SEA LEK!
66F - OFFSIIF
PL - PROPERTY UNE
PC - Pow OF DIRYAFURE
Poe - PCN7 OF BEARING
PRC - PONT OF REVERSE CURVE
PT - POWr OF IANCENCr
PW - PONT OF V RTMAL WIERSECRON
RED - REDD(ER
Rr - AYWIr
ROW - RIGHT OF WAY
RP - RADIUS PONr
SEP - SEPARA?XW
9 - SRREEr WrQISECRCW
SP - SNGLE PUAD'ER
SU - SWIGN
SIO - STANDARD
75C - TOP BACK OF aim
TOP - TOP OF PIPE
7P - IDP OF PAVENENr
W - VALVE Box
K - VERRrAL CLOVE
CONSTRUCTION NOTES
7. ALL CONSTRUCTION SHALL BE INSTALLED AS SPECIFIED IN THE MOST CURRENT EDITION
OF THE MUNICIPALITY OF ANGNORAGE STANDARD SPECF7CA77ONS FOR
STREETS-DRAINAGE-UPU77£S-PARKS (MASS), THE AWW7 DESIGN AND CONS7RU17770N
PRACTICES MANUAL, AND THE SPECIAL PROVISIONS.
2, MAINTAIN A MINIMUM OF TEN (10) FEET HORIZONTAL AND EIGHTEEN (18) INCHES
VERTICAL SEPARATION BETKEEN WATER AND SANITARY OR STORK SEVER MAINS AND
SERVICES SANITARY AND STORM SEWER PIPE JOINTS SHALL BE PLACED AT LEAST NINE
(9) FEET FROM ANY WATERLINE CROSSING.
J. MAINTAIN A MIMIMIAM OF 36 -INCHES OF VERTICAL SEPARATION SETN£EN ANY STORM
SEWER (STORM DRAIN OR F0077NG DRAIN) AND WATERLINE (MAINS OR SERVICES) O7
SANITARY SEWER (MAINS OR SERVICES). 1F 36 -INCHES CANNOT BE MAINTAINED. PROVIDE
A MINIIUM OF 4 -INCH 7HICK INSULATION.
4. ALL WA TER/SEWER PIPE INSULATION SHALL BE RIOD BOARD, HIGH DENSITY EXTRUDED
POL YSTYREN£, MIN. 60 ASL, FOR UNDERGROUND INSTALLA BONS £OUIVAL£NT TO R-20
PER FOUR (4) INCH THICK WSULA770V.
S CONTRACTOR SHALL VERIFY AND RECORD THE HORIZONTAL AND VERTICAL LOCATIONS
OF ALL U77U77ES ENCOUNTERED IN 7HE RELD AND RECORD ANY CHANGES ON THE
CONTRACTOR RECORD ORAWNGS.
6. THE CONTRACTOR SHALL RESTORE ALL DISTURBED PROPERTY, INCLUDING DRAINAGE
SWALES, DJ57URBED BY rGNTRACT ACTIVITIES TO PRECONSTRUCTION CONDITIOIL
7. IN CASE OF CONFLICT BETWEEN STATIONING LOCATTON OF PIPE OR FITTINGS, USE
DIMENSIONED LOCA TIONS RELATIVE TO WE CEN7ERUNE AND PROPERTY UNIT THE
DIMENSIONED LOG1 RONS SHAH GOVERN.
8. THE CONTRACTOR SHALL RECORD SURVEY N07ES FOR SUBMITTAL W77H RECORD
DRAWING PLANS PRIOR TO CONTRACT FINAL PAYMENT.
9. COV7RACTOR SHALL FIELD INSTALL RESTRAINED F7T77NCS ON ALL MECHANICAL JaNTS.
70. THE CON7RACTOR SHALL B£ RESPONSIBLE FOR EROSION AND SEDIMENT CONTROLS AS
NECESSARY TO COMPLY Y47H FEDERAI. STATE AND MUNICIPAL LAWS THAT PROHIBIT
UNPERWI7TED DISCHARGE OF POLLUTANTS, INCLUDING SEOLM£NM THAT ARE A RESULT OF
EROSION AND OTHER CONSTRUCTION ACTIVITIES THE CONTRACTOR SHALL CONDUCT ALL
WORK SO SEDIMENT ES NOT 7RANSPORTEO ONTO THE ROADWAY OR ADJACENT PROPERTY.
AT A MINIMUM, THE CONTRACTOR SHALL SWEEP UP ANY SEDIMENT 7RACXED ONTO PAVED
SURFACES IN PUBLIC RICHT-OF-WAY K17HIN 24 HOURS OF THE TRACKING TO MINIMIZE THE
WASH -OFF OF SEDIMENT INTO THE STORM DRAINS OR WA TER WA YS
SEWER NOTES
7. EQ7S77NG CUSTOMERS SHALL 6E NORRED SEVENTY-TWO (72) HOURS IN ADVANCE OF
SANITARY SEWER SERVICE 1NIERRUPAON. THE C0N7RACTOR SHALL BE RESPONSIBLE TO
PROVIDE TEMPORARY SANITARY SEWER SERVICE TO 771E EXISTING CUSTOMERS IF DEEMED
NECESSARY BY THE ENGINEER,
2 ALL MANHOLES SHALL HAW A MIMLMUM OF ONE -SIX (6) INCH GRADE RING. MAXIMUM
GRADE RING ADJUSTMENT SHALL NOT EXCEED EIGHIFEN (78) INCHES
.I ALL SANITARY SEWER MAINS SHALL BE POLYWNIZ CHLORIDE (PVC) C-900, DR -18
4. SANITARY SEWER SERVICES SHALL BE — A! — UNLESS N07ED ON PLANS WIN A
MINIMUM SLOPE FOR 6 -INCE SERVICES TO HE IX AND FOR 4-INCf SERVICES TO BE 29
5. SANITARY SEWER SERVICES SHAD BE PLACED NO CLOSER THAN. 15 FEET
HORIZONTALLY MEASURED TO ANY FRE HYDRANT OR FIRE HYDRANT LEG. 70 FEET
HORIZONTALLY MEASURED TO ANY WATER NAM, WATER SERIICE, STORM SEWER, F007WC
DRAIN, STREET LIGHT, TRANSFORMER PAD, Q£C7RICAL/TELEPHONE/CABLE BOX, AND 5 FEET
HOR12LWTALLY MEASURED TO ANY SIDE LOT LINE.
6. ALL BEDDING SHALL BE TYPE E
7. SEWER MAIN AND SERVICE 7RENCHES AND BEDDING SHALL BE COVPACTED TO A MINIMUM OF 95X
MAXIMUM DENSITY
8. THE CONTRACTOR SHALL RELOCATE ANY SEINER SERVICE CONNEC77ONS INSTALLED WIN
LESS THAN MINIMUM STANDARD MEASURED DISTANCES PRIOR TO FINAL ACCEPTANCE BY AWWU
9. THE CDNIRACToR SHALL REVIEW MASS DETAIL 60-7 ON SHEET G4 OF B AND BECOME
FAMILIAR WITH THE LATEST REWSON TO THE MANHOLE DE7A1L DENOTING Z -LOG
81 TUMINOUS WATER PROGRNG, AND MAC WRAP.
10. SER NCE UNE FROM MAIN TO PROPERTY UNE MUST B£ CHECKED TO BE SURE IT IS OPEN
AND OPERA 77NG PRIOR 70 INSTALLING NEW PIPE
OWNER-
12870 OLD SEWARD
HIGHWAY SU17E 108 GARNESS ENGINEERING GROUP LTD.
3701 EAST TUDOR ROAD SUITE 101
ANCHORAGE, AK, 99507
MGJ BUILDING GROUP 907-337-6179
907-222-1908
OtmTER PS 20-036
Ars Ars -1EFWmj \!Y —
G.ARNESS ENGINEERING GROUP, Ltd
ENGINEERING SALES CONSULTING-
_ 9
` f
6
A
'
THIS PROJECT
m
+moi
r�
SEWER KEY MAP
N.T.S.
CONSTRUCTION NOTES
7. ALL CONSTRUCTION SHALL BE INSTALLED AS SPECIFIED IN THE MOST CURRENT EDITION
OF THE MUNICIPALITY OF ANGNORAGE STANDARD SPECF7CA77ONS FOR
STREETS-DRAINAGE-UPU77£S-PARKS (MASS), THE AWW7 DESIGN AND CONS7RU17770N
PRACTICES MANUAL, AND THE SPECIAL PROVISIONS.
2, MAINTAIN A MINIMUM OF TEN (10) FEET HORIZONTAL AND EIGHTEEN (18) INCHES
VERTICAL SEPARATION BETKEEN WATER AND SANITARY OR STORK SEVER MAINS AND
SERVICES SANITARY AND STORM SEWER PIPE JOINTS SHALL BE PLACED AT LEAST NINE
(9) FEET FROM ANY WATERLINE CROSSING.
J. MAINTAIN A MIMIMIAM OF 36 -INCHES OF VERTICAL SEPARATION SETN£EN ANY STORM
SEWER (STORM DRAIN OR F0077NG DRAIN) AND WATERLINE (MAINS OR SERVICES) O7
SANITARY SEWER (MAINS OR SERVICES). 1F 36 -INCHES CANNOT BE MAINTAINED. PROVIDE
A MINIIUM OF 4 -INCH 7HICK INSULATION.
4. ALL WA TER/SEWER PIPE INSULATION SHALL BE RIOD BOARD, HIGH DENSITY EXTRUDED
POL YSTYREN£, MIN. 60 ASL, FOR UNDERGROUND INSTALLA BONS £OUIVAL£NT TO R-20
PER FOUR (4) INCH THICK WSULA770V.
S CONTRACTOR SHALL VERIFY AND RECORD THE HORIZONTAL AND VERTICAL LOCATIONS
OF ALL U77U77ES ENCOUNTERED IN 7HE RELD AND RECORD ANY CHANGES ON THE
CONTRACTOR RECORD ORAWNGS.
6. THE CONTRACTOR SHALL RESTORE ALL DISTURBED PROPERTY, INCLUDING DRAINAGE
SWALES, DJ57URBED BY rGNTRACT ACTIVITIES TO PRECONSTRUCTION CONDITIOIL
7. IN CASE OF CONFLICT BETWEEN STATIONING LOCATTON OF PIPE OR FITTINGS, USE
DIMENSIONED LOCA TIONS RELATIVE TO WE CEN7ERUNE AND PROPERTY UNIT THE
DIMENSIONED LOG1 RONS SHAH GOVERN.
8. THE CONTRACTOR SHALL RECORD SURVEY N07ES FOR SUBMITTAL W77H RECORD
DRAWING PLANS PRIOR TO CONTRACT FINAL PAYMENT.
9. COV7RACTOR SHALL FIELD INSTALL RESTRAINED F7T77NCS ON ALL MECHANICAL JaNTS.
70. THE CON7RACTOR SHALL B£ RESPONSIBLE FOR EROSION AND SEDIMENT CONTROLS AS
NECESSARY TO COMPLY Y47H FEDERAI. STATE AND MUNICIPAL LAWS THAT PROHIBIT
UNPERWI7TED DISCHARGE OF POLLUTANTS, INCLUDING SEOLM£NM THAT ARE A RESULT OF
EROSION AND OTHER CONSTRUCTION ACTIVITIES THE CONTRACTOR SHALL CONDUCT ALL
WORK SO SEDIMENT ES NOT 7RANSPORTEO ONTO THE ROADWAY OR ADJACENT PROPERTY.
AT A MINIMUM, THE CONTRACTOR SHALL SWEEP UP ANY SEDIMENT 7RACXED ONTO PAVED
SURFACES IN PUBLIC RICHT-OF-WAY K17HIN 24 HOURS OF THE TRACKING TO MINIMIZE THE
WASH -OFF OF SEDIMENT INTO THE STORM DRAINS OR WA TER WA YS
SEWER NOTES
7. EQ7S77NG CUSTOMERS SHALL 6E NORRED SEVENTY-TWO (72) HOURS IN ADVANCE OF
SANITARY SEWER SERVICE 1NIERRUPAON. THE C0N7RACTOR SHALL BE RESPONSIBLE TO
PROVIDE TEMPORARY SANITARY SEWER SERVICE TO 771E EXISTING CUSTOMERS IF DEEMED
NECESSARY BY THE ENGINEER,
2 ALL MANHOLES SHALL HAW A MIMLMUM OF ONE -SIX (6) INCH GRADE RING. MAXIMUM
GRADE RING ADJUSTMENT SHALL NOT EXCEED EIGHIFEN (78) INCHES
.I ALL SANITARY SEWER MAINS SHALL BE POLYWNIZ CHLORIDE (PVC) C-900, DR -18
4. SANITARY SEWER SERVICES SHALL BE — A! — UNLESS N07ED ON PLANS WIN A
MINIMUM SLOPE FOR 6 -INCE SERVICES TO HE IX AND FOR 4-INCf SERVICES TO BE 29
5. SANITARY SEWER SERVICES SHAD BE PLACED NO CLOSER THAN. 15 FEET
HORIZONTALLY MEASURED TO ANY FRE HYDRANT OR FIRE HYDRANT LEG. 70 FEET
HORIZONTALLY MEASURED TO ANY WATER NAM, WATER SERIICE, STORM SEWER, F007WC
DRAIN, STREET LIGHT, TRANSFORMER PAD, Q£C7RICAL/TELEPHONE/CABLE BOX, AND 5 FEET
HOR12LWTALLY MEASURED TO ANY SIDE LOT LINE.
6. ALL BEDDING SHALL BE TYPE E
7. SEWER MAIN AND SERVICE 7RENCHES AND BEDDING SHALL BE COVPACTED TO A MINIMUM OF 95X
MAXIMUM DENSITY
8. THE CONTRACTOR SHALL RELOCATE ANY SEINER SERVICE CONNEC77ONS INSTALLED WIN
LESS THAN MINIMUM STANDARD MEASURED DISTANCES PRIOR TO FINAL ACCEPTANCE BY AWWU
9. THE CDNIRACToR SHALL REVIEW MASS DETAIL 60-7 ON SHEET G4 OF B AND BECOME
FAMILIAR WITH THE LATEST REWSON TO THE MANHOLE DE7A1L DENOTING Z -LOG
81 TUMINOUS WATER PROGRNG, AND MAC WRAP.
10. SER NCE UNE FROM MAIN TO PROPERTY UNE MUST B£ CHECKED TO BE SURE IT IS OPEN
AND OPERA 77NG PRIOR 70 INSTALLING NEW PIPE
OWNER-
12870 OLD SEWARD
HIGHWAY SU17E 108 GARNESS ENGINEERING GROUP LTD.
3701 EAST TUDOR ROAD SUITE 101
ANCHORAGE, AK, 99507
MGJ BUILDING GROUP 907-337-6179
907-222-1908
OtmTER PS 20-036
Ars Ars -1EFWmj \!Y —
G.ARNESS ENGINEERING GROUP, Ltd
ENGINEERING SALES CONSULTING-
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP221030, Deb Wockenfuss, 02/14/22
MUNICIPALITY
OF ANCHORAGE
Development Services Department
-
.'� Phone: 907-343-7904
On -Site Water & Wastewater Section-'
Fax: 907-343-7997
Certificate of On -Site Systems Approval
Parcel I.D. 075-132-05-009
Expiration Date: 8/7/2025
Leqal description US SURVEY 3042 LT 3 T10N R2E SEC 19 POWDER RUN
Site address 116 POWDER RUN LN Girdwood AK 99587
Current property owner(s) SIMMONS LESLIE D &SLAUGHTER MARK WILLIAM
X The On-site system(s) is/are approved for 3 bedrooms
Conditional approval for bedrooms, with the following stipulations:
Comments or advisories:
Original Certificate Date:
11/12/2024
his Certificate of On -Site Systems Approval (COSA) is intended to demonstrate the subject
system(s) is/are in substantial compliance with municipal code. The Municipality of
Anchorage, Development Services Department (DSD) issues COSAs based upon
representations provided by an independent professional engineer. The Municipality of
Anchorage is not responsible for errors or omissions in the professional engineer's work.
ATTACHMENTS:
COSA Checklist X Well Flow Advisory
Absorption Field Advisory Nitrate Advisory
Tank Age Advisory Arsenic Advisory
Other
COSA ApprovaLkne 2022
MUNICIPALITY OF ANCHORAGE
Development Services Department Phone: 907-343-7904
On -Site Water J?_ IN Section Fax: 907-343-7997
Certificate of On -Site Systems Approval Application
Y PP PP
1. GENERAL INFORMATION
Parcel I.D. 075-132-05
Complete legal description US Survey 3042 Lot 3 T1 ON R2E Section 19 Powder Run
Location (site address)
122 and 116 Powder Run Lane, Girdwood, AK 99587
Current property owner(s) Mark Slaughter & Leslie Simmons Day phone
2. ON-SITE SYSTEMS SIZED FOR 3 BEDROOMS
3. TYPE OF WATER SUPPLY: ❑■ Private Well ❑ Private Well serving 2 dwelling units
❑ Private Well serving 3+ dwelling units ❑ Community Well or Public
❑ Water Storage
4. TYPE OF WASTEWATER DISPOSAL: ❑ Private Septic ❑ Private Septic serving 2 dwelling units
❑ Holding Tank ❑■ Community Septic or Public Sewer
Gr.71Pliiiiiiiiiiiii���1q
Age N/A - See advisory if steel older than 20 years
Waiver request for:
Expedited review requested: ❑■
Distance:
By applying for this entitlement, this property is subject to inspection by municipal On-site staff
to verify the accuracy of the information provided.
COSA Fee $ z
Date of Payment l Z Z
COSA # 6 Z y y C-�
Waiver Fee $
Date of Payment
Waiver #
COSA Application—June 2022
US Survey 3042 Lot 3 T10N R2E Section 19 Powder Run 075-132-05
N/A
02/15/22 105 N/A
105
0.48
>18
N/A Forge Engineering
N/A 8/7/24
Well serves two properties and cannot be isolated for well testing.
>
Property is served by AWWU
Benjamin Schiller, P.E.11/8/24
N/A
N/A
Property is served by AWWU
(907) 522-7773
coce)
�C?
O O
CD CD
LU o L
V a_
0
2
U
Z
a
7_//
J �
a -
n C U
L L^'
- Q W
Z
U�
U
.L
06
co L
C
E�
o_
O
> U)
a) c
00
LJ
LO
N
O
N
co
ai
cu
D
C
O
.Q
X
W
co
CD0
LO
O
N
M
ti
0
a)
U
d
Z
ry
W
0
U
W
W
N
Z
LLCD
1�
J
N
C)
M
�W
L.L
U)
c
O
,-r—
U)
U)
()
an
a)
J
r -
co
LO
0)
CD
Q
O
O
,L.
V
J
D
Of
W
a_
N
N
U
m
cu
a�
O
C/)
)
L
(ti
L
06
^U)
W
a)
0
a)
0-
0
n
C:
U
r�t'7
0
70
>
O
Q
cu
a)
L
m
Ln
E
a)
(n
a)
N
c
0
a)
m
A
ON
i
M
V O =O O
O
CL
^, Q /W�� CL
o c
E F— O
� U
� d �
O p C
� N �
C CL —
•� E ui
V) +� = Oi
3 0 a
O �
m i C
>
O d
CL CL Q
V
E c
0
�+ = co
cQ N
a .
O o
O>
O a)
+O+ C
v N O
�j E o w
N a) t
V
NQ.
k N Q �
L
X
O
V)
.Ln
Y>
U
LL 70
OQ
U Za)
p Q
Z
~ LO Y
W O
U Q F: O
2
U
Q
H
Q
a
a
0
U
0
cv
.Q
Q
ca
O
Q-
cn
(\n
CO
W
C
0
O
N
W
W,
W
O
O
Z U')
09
Q M
-r--
0
O LO
LL
Z O
QJ Q
W =
Z v
LU
0 n
N
O
_U
L
c
O
N
>
a
>
m
d
(Y)
U)
o
C
O
-
N
j
d
0
I�
>,
N
O
0)
O
•U
•c
:3
3
�=
=
E
E
o
U
U
C
C)
U
co
D
CL
N
•�
❑
n
(n
a)
U
c
ca
�
�
a
a)
_
13
❑
U
O
cru
>
+
M
n
�
d
�N
a)
U
O❑
c
co
/}�
\V
co
W
m
—
N
a)
cm
o
C/)J
L
I'1
❑
N
A 1
CMI
>
L
>
(�
Na,
/V�J
«/
)
O
N
fn
N
El
J�
a
co
L
E]
E:]-+
0
a.
w
Q
yO
L
wwL
r
W
Q
F•
Q
o
O-
y
W
F-
LL
O
N
Mn
LL
O
O
Cl)
W
.0))
W
z
a
❑
a
U
O
~
L
F-
N M d•
a)
LL
Lm
C,
c
()
M
0
m
*k
a)
c
m
>1
co
IL
0
a)
0
R
L
N
?
d
N
U)
C
U
d
O
cB
•U
U
U
_
CL
❑
E
a)
U
13
O
E
E
°'
U
c
r
~M
L
O
m
a)
N
Mn
D
O
.0))
❑
A0) Q.
i.f.
L
O
=
Q- O
o
a)
a)
L �
U)
O
❑
EQ
a) r
voi
-a
->O
a)
j
y-
O
m
a)
a) >,
CD
a
Q
N V
)
V)
L
L)
.�
�
O
LV
C/)
a)
w m
Z
L
a)
>+
a)
L
:tl'
a _
Q
>
a)
Md
'
mn
w
�>
m
a)
LL
Lm
C,
c
()
M
0
m
*k
a)
c
m
>1
co
IL
0
a)
0
US Survey 3042 L3 T10 R23 SEC 19 075-132-05-008
N/A
02/15/22 105 N/A
105
0.48
N/A Forge Engineering
N/A 8/7/24
N/A N/A
N/A
>
Benjamin Schiller, P.E.8/21/24
N/A
N/A
Property is served by AWWU.
(907) 522-7773
HUHUPAUTYOFAHCHORQGE
Development Services Department 4.
p p � - T Phone: 907-343-7904
On -Site Water & Wastewater Section Fax- 907-343-7997
Certificate of On -Site Systems Approval
Parcel I.D. 075-132-05
Legal description US SURVEY 3042 LT 3
Site address 122 and 116 Powder Run Lane
Expiration Date: 7/5/23
Current property owner(s) MGJ BUILDING GROUP LLC
X The On-site system(s) is/are approved for 3/3 bedrooms
Conditional approval for bedrooms, with the following stipulations:
Comments or advisories:
BY lav Original Certificate Date: 4/5/23
This Certificate of On -Site Systems Approval (COSA) is intended to demonstrate the subject
system(s) is/are in substantial compliance with municipal code. The Municipality of
Anchorage, Development Services Department (DSD) issues COSAs based upon
representations provided by an independent professional engineer. The Municipality of
Anchorage is not responsible for errors or omissions in the professional engineer's work.
ATTACHMENTS:
COSA Checklist X Well Flow Advisory
Absorption Field Advisory Nitrate Advisory
Tank Age Advisory Arsenic Advisory
Other
COSA Approval—June 2022
MUMCIPAUTY OF ANCHORAGE
»o zA
Development Services Department P P Phone: 907-343-7904
On -Site Water & Wastewater Section Fax: 907-343-7997
Certificate of On -Site Systems Approval Application
1. GENERAL INFORMATION
Parcel I.D. 075-132-05
Complete legal description US SURVEY 3042 LOT 3
Location (site address) 122 AND 116 SPROAT ROAD
Current property owner(s) MGJ BUILDING GROUP Day phone 907-306-7079
2. ON-SITE SYSTEMS SIZED FOR 3/3 BEDROOMS
3. TYPE OF WATER SUPPLY: ❑ Private Well 0 Private Well serving 2 dwelling units
❑ Private Well serving 3+ dwelling units ❑ Community Well or Public
❑ Water Storage
4. TYPE OF WASTEWATER DISPOSAL: ❑ Private Septic ❑ Private Septic serving 2 dwelling units
❑ Holding Tank 0 Community Septic or Public Sewer
5. SEPTIC TANK: ❑ Steel ❑ Plastic ❑ Concrete ❑ Fiberglass
Age - See advisory if steel older than 20 years
6. ABSORPTION FIELD: ❑ AWWTS Deep Trench ❑® Wide Trench ❑ Seepage Pit
Waive
Expedited review requested: ❑
Distance:
By applying for this entitlement, this property is subject to inspection by municipal On-site staff
to verify the accuracy of the information provided.
COSA Fee $-?, —0
Date of PaymentYZ31Z I
COSA# OSC 2'310130
Waiver Fee $
Date of Payment
Waiver #
COSA Application—June 2022
COSA Checklist
Legal Description: US SURVEY 3042 LOT 3 T10N R2E SECTION 19 POWDER RUN Parcel ID: 075-132-05
If more than I well and/or septic system on lot, provide separate checklist. Structure served by this system
A. WELL DATA
X Well log is filed with Onsite (or attached)
Date drilled 2/15/2022 Total depth L05 ft
Cased to 105 ft
9 Sanitary seal is functioning correctly
ny Wires are properly protected
Casing height (above ground) 18+ in.
Date of flow test for COSA 2/15/2022
Static water level at beginning of test 15 ft.
Comments
B. TANK DATA
Measured operating fluid level in
Date of pumping
M Requires
Well production at time of test 20
gpm
Water storage tank volume N/A gallons
Well disinfected for coliform test?Yes El No
ML
Coliform bacteria is Negative
Nitrate mg/L nN Nitrate less than MRL (ND)
Arsenic ug/L 9 Arsenic less than MRL (ND)
Collected by SULLIVAN WATER WELLS
Date 1/16/2023
ISERVED BY AWWU SEWERI
C. LIFT STATION
-15 �k ❑ Required maintenanc
r
— Age of lift statin years
completed, if AWWTS Lift stat' aterial
D. ABSORPTION FIELD DATA
Which system tested (date installed)
Fj ALL standpipes present per record drawing
Total measured depth from grade ft (max)
Measured depth to pipe invert from grade ft (min)
El N/A — pressurized field.
El Per record drawings, field is insulated.
F1 Monitor tubes go to bottom of effective.
If not, state depth into effective
❑ Presoaked required if
Presoaked required
(Required if house vacant or not used for more
d if
vacant
not used
than 30 days prior to da test)
Gallons introdu I s
-gallons date
A j
Any rejuve n treatment (past 12 months)
I s, enter date
Adequacy test date -.00
Results n Pass
esu' s Pass
Fluid depth prior to t in
prior
Water added _ gal
New i depth _ in
ern
apsed time min
Final fluid depth _ in
Absorption rate _ gpd
FIELD STATUS — POST RECOVERY
Effective depth (per record drawings) in
Effective depth used in
Effective depth remaining in
A
Comments/Deficiencies: SEWER LINE RECORD DRAWINGS HAVE NOT BEEN APPROVED AND/OR SUBMITTED TO AWWU ?4
COSA ChecklistJune2022
E. SEPARATION DISTANCES
From Private Well on Lot to: (Please enter distances if less than required or if community well on lot)
Septic Tank/Lift Station on Lot > 100' Community Sewer Manhole/Cleanout > 100'
❑Yes if No NIA ft FC Yes if No ft
Neighboring Tank > 100' ❑m Yes if No ft Private Sewer/Septic Line > 25' Q Yes if No * ft
Absorption Field on Lot > 100' ❑ Yes if No N/A ft Holding Tank > 100' W Yes if No ft
Neighboring Absorption Fields > 100' Animal Containment > 50' Q Yes if No ft
Rm Yes if No ft
Manure/Animal Excreta Storage > 100'
Community Sewer Main > 75' DYes if No ft 0 Yes if No ft
❑ N/A — Served by Community Well (not on lot) or Public Water
From Septic/Holding Tank and Absorption Field(s) on Lot to: (Please enter distances if less than
Building Foundations > 10'
Tank to Property Line > 5'
Field to Property Line > 10'
Water Main > 10' ,,,,•
Line > 10'
❑ Yes if No ft
❑ Yes if No ft
❑Yes i ft
Yes if No ft
❑ Yes if No ft
Surface Water >
Adjacent Lots:
Private Wells > 100'
Community Wells > 200'
Yes if No ft
❑ Yes if No ft
❑ Yes if No ft
If tank or field is under driveway comment below
F. ENGINEER'S COMMENTS
"SEE ATTACHED DRAWING BY A PLS WHICH SHOWS THE SEWER LINE AND CLEANOUT LOCATIONS
G. CERTIFICATION & STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based
on procedures outlined in the Certificate of On -Site Systems Approval Guidelines, indicates that the on-site water
supply and/or wastewater disposal system appears to comply with applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation, unless noted otherwise.
Name of Firm Garness Engineering Group, LTD. (GEG) Phone
Engineer's Printed Name Jeffrey A. Gayness Date _
In conducting this evaluation, GEG provided an engineering evaluation of the well and/or septic system in
accordance with the guidelines and regulations established by the Municipality of Anchorage and industry
practices. The reported results describe the condition of the system/s on the date/s of the evaluation.
Separation distances were measured to readily identifiable features. Hidden defects or encroachments may
exist that were not identified during the evaluation. The operational life of all wells and septic systems depend
upon a variety of variables, including (but not limited to) soil conditions, groundwater levels (that may fluctuate
during the year), quality of construction (materials and workmanship), and the water usage of the family utilizing
the systems. These conditions can vary, and are outside the control of GEG. Satisfactory test results do not
guarantee future performance of the system/s; therefore, GEG makes no warranty (express or implied) regarding
the future performance of the well or septic system. GEG makes no representation whether an aftemative well
or septic system can be installed on the property in the event either of the current systems fail to perform
adequately in the future. The content of this report is for the sole benefit of the person/party that retained GEG
to perform the evaluation. Reliance upon the information provided in this report by any other person or party
(including subsequent property purchasers) is not authorized, nor will it confer any legal right whatsoever.
COSA Checklist June 2022
907-337-6179
n f Go ess.
4�
CE—1,
:UCENSE ,rofes ion°o
#AECCW4
iA