Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SUN VALLEY NORTH BLK 4 LT 8
Onsite File Sun Valley North Block 4 Lot 8 #050-662-08 Municipality of Anchorage On -Site Water and Wastewater Section - (907) 343-7904 Page 1 of 3 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP221217 PID Number: 050-662-08 Dwelling: RE Single Family (SF) FE with ADU R Duplex (D) R Two Single Family Project: A New M Upgrade Name SHERWOOD KIRK W & ELIZABETH ABSORPTION FIELD ❑ Deep Trench RE Wide Trench R Bed F-1 Mound Site Address NHN Hiland Road Eagle River E] Other Phone Number of Bedrooms Soil Rating depth from original grade 1 4 6 GPD/SF JTotal 6 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade 5A0 Ft. Gravel depth beneath pipe 0.5 Ft, Subdivision Block Lot SUN VALLEY NORTH BLK 4 LT 8 Fill added above original grade -0 Ft, Gravel length 20 Ft. Township Range Section Gravel width 5 Ft. Beds: Number of Lines Distance between lines Ft. SEPARATION DISTANCES ToySeptic AbsorptionHolding Lift Station Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Tank Line 100 Ft2 1 Ft. Well 1> 100, > 100' > 100'! NA > TANK [I Septic 0 S.T.E.P. E] Holding X Other Manufacturer Anchorage Tank Capacity 1500 Gal. Surface Water I > 100, > 100,1> 100"; NA I Material plastic Number of compartments 2 I i I Lot Line > 5' > 100'1 > 5' 11 NA NA Foundation I LIFT STATION Manufacturer green Capacity 1000 Gal. II Remarks no foundation constructed yet 2' sand layer below sewer rock Alarm location Electrical installed by ------ - ----------- - --- not installed not installed PIPE MATERIAL House to tank 3034 drainfield Tank to PVC Installer Dean Excavation Drainfield 3034 CO/MT 3034 Inspector Curtis Townsend BENCH MARK (Assumed elevation) 312.20 ft Inspection 1s, 7/15/2022 7/16/2022 Location and description dates: 2nd V 411,5/6/2026 top of FAP pod lid ON-SITE WATER AND WASTEWATER SECTION APPROVAL Engineers Stamp Conditional Approval: Date . . ......... Yi F. . ......... Dato Septic System .'/` Approved Dat PROH Zote: this approval does not include well permit requirem nts. (Rev 05/02/18) 0j Josiah Streff NHN Hiland Road Eagle River, Alaska 99577 SUN VALLEY NORTH BLOCK 4 LOT 8 EKLUTNA ENGINEERING, LLC DATE: SCALE: PID: 050-662-08 rol. 05/17/2025 CLT 1"=50' SHEET 2 OF 3 28 I . FINISHED GRADE ELEVATIONS WERE TAKEN FROM THE SURVEY AS BUILT DATA. BENCHMARK r=K EL E'_VATION WAS ESrABLISSIHED FROM S„I `,JF`' DATA. 2. FINALGRA'DIN'G AROUND TANKAGE TO BE COMPLETE..D WHEN S EnCCT'J(<E IS COMPLETED. 3. FILTER SAND HAS MOVED VFFR IC:AU Y IJP 'HF 90TT'OM OF CHET. MON TC:c TURES. THIS IS CC BE ADDRESSED _ATER AS THE BOTTOM 01= THE ROCK COULD NO! BE SEEN IN MAY 2025. 4. A. 1,000 GAL -i -O -i PLASMIC GRIFER TANK HAS BEEN INSTAL! ED AS SINGLE C;OMP.AR , <. ENT TANK. THIS fS T kit USED liv THE FUTURE AS A. LIFT, S A [i0"ti. ^'R A MAX JN BEDROOM A U. 5. NO SWING TIES ��RE PROVIDED AS NO STRUCTURE HAS BEEN CONSTRUCTED. 6- PUMP HAS BEEN PLACED IN i t -IE I '___._. CASING BU? NO PC-:WE_iR IS PROVIDED AT TF IS TIME. 7. CONTROL PANELS FOR LIFT Sl-ATIONS AND ADVANTEX TANKS HAVE N 1T BEEN iNS CALLED AT T'r1IS TiM . ST";RT' P OF .r THE HAS ", G i ADVANTX k- A NO BEEN COMPLE I ED. 8, TEST HOLE PIPE STILL PRESENT, ? 5' AWAY FROM FIELD, WATER NOT OBSERVED MAY 2025. EX1STINI GROUND IS APPROXIMATELY 327 ,000 G PLASTIC, STEP TANK 312.20 308.5 1500 gal ORENCO FAP TANK W/ AX20 FILTER 2' SAND LAYER BELOW SEWER ROCK PUMP VAULT 335.0 QELi FERC TE >?. < , mipi SP TH DURING MONTH Or 332.01JUNE AND GROUNDWATER WAS NCT ENCOUNTERED r n 44** Josiah Streif . •��� NHN Hiland Road Eagle River, Alaska 99577 SUN VALLEY NORTH BLOCK 4 LOT 8Ar s OSP221217 . ..: ....................... DATE: 05/17/2025 � .,.� EKLUTNA ENGINEERING, LLC •�= ri F, DRAWN. CLT �! 1 ? SCALE: 1" = 10'�..,�" yrs PID: 050-662-08 SHEET 3 OF 3 xrtitia '� r Note: This Septic MH(Lift Station) and 2Septic vent pipes _"^M"C"VII ~"y '.�"^� OF TH L3— 10393 I hereby certify that ( ha,osunnyud the following described property: Lot 8.Block 4`Sun Valley North, Plat No. 8]-2V7, Anchorage Recording District, and that noencroachments exist except asindicated hurcnn. This As -built will only show the casements that appear unthe recorded subdivision Plat No. 8]'297` Anchorage Recording Diatrict,:under uucircumstances should this data hereon be used for the construction or establishing boundary or fence lines. 0 4P 80 SCALE wFEET Surveyed: March 9,x024 Sun Valley North Lot 8.Block 4 AaDepicted on: Plat No. 83-2Q7 Anchorage Recording District GRID: SVV0758 ASBMI|T SHRVEY Josiah Streff poBox mm52 Anchorage, Alaska 99524 ����� H� ' APB Surveying 24V1TenowkDrive Anchorage, Alaska g95O (9V7)227 -13O1 Pump Installation Log Arctic Pump & Well Inc . Jim Sullivan PO Box 770197 Eagle River, AK 99577 (907) 688 -2510 (907) 243 -2282 jim@arcticpump.com osp221217 05066208000 7/1/2022 Sun Valley North B4 L8 8 4 Dean Construction 22222 Elkhorn cir Eagle River AK 99577 10/20/2023 113 Feet Franklin 10FRD05P4-2W230 153 PSI 13 Feet ss Well Drilling Permit Number: Parcel Identification Number: Date Of Issue: Legal Description Lot: Block: Property Owner Name Address: Pump Installaion Date: Pump Intake Depth Below Top of Well Casing: Pump Manufacturer's Name Pump Model: Pump Size: Pitless Adapter Burial Depth: Pitless Adapter Manufacturer's Name Pitless Adapter Installer: Well Disinfected Upon Completion? Method of Disinfection: u/k Yes Chlorine Comments: Pump Installer Name: Arctic Pump & Well, Inc. 5Y Friday, December 20, 2024 I V V We a :FO&i FIV URTS: — Permit Number: # S Date of Issue: Parcel Identification Number: Date Ste • �'® �_ Is well located at approved permit Dation? Yea No • --- iBate Completed: � PftPsrty Legal Description: S�s���`Y ..�°�,%r�r' Owner Name & Address.- Arsenic: d : Borehole ih, MEMDepth �) Soil ,'Thickness @Vater Strata From Tn genic: Nitrates: Total coliform Bacteria: Other Bacteria: ®m91L 0010nies/100mL .�._ col/100mL Method of Drillingo air rotary ® cable tool Ca : F rc �- Wall Thickness: Diameter: inches:I� feet Liner Diameter: inches few Cooing stickup alcoveground: feet Static water Wei (frons ground level):. 3 'feet Pumping level: feet after hours pumping jpm ReeoveryRate: Method of Test1nr: _ &i/' �1<' 63pen End ® n mole ® Screened Start feet Stopped feet ® Perforations Start feet Stopped feet asst _i: '-0W4,;' - o ndn+ee Pustsp: Intake Depth favi Pump size - hp Brand Name® Well DWafected Upon Coos ledon? ayes ® No Method of Disinfection: Comments: Well Driller: lam! x? Attention.* The well driller shall Provide a well log to DSD within 30 days of completion. MUN ICIPALITY OF ANCHORAGE On-Site Water & Wastewater program PO Box 196650 4700 Elmore Road Anchorage, Alaska 995'19-6650 Phone: (907) 343-7904 Fax (907) 349-7eg7 http ://www. muni.org/onsite Effective Date: Expiration Date: Lot Size in Sq Ft: TotalBedrooms: partnretrr On€ite Water & Wastewater System permit Permit Number: OSP22121T Work Type: WellSeptic Initial Tax Code Number: 05066208000 Site Legal Address: SUN VALLEYNORTH BLK 4 LT B G:0758 Site Mailing Address: Owner: SHERWOOD K|RK W & ELTZABETH Design Engineer: EKLUTNA ENGINEERtNGt LLC* This permit is for the construction of: EI Disposat Field M Septic Tank E Hotding Tank E erivy Received By: M Private Well E Water Storaoe All construction shall be in accordance with: 1, The attached approved design. 2. All requirem the state of AlaskaWastewater 3. The wastew 80) Services De tifY;the DeveloPment 4. From October 15 to April 15, a subsurface soilabsor ririg freezing weathershall be either: a. Opened and Closed on the same day, orb. Covered, sealed, and heated to prevent freezing 71112022 711t2023 155604 4 Issued By: MUNICIPALITY OF ANCHORAGE Development Services Department p p l Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 ON-SITE SEPTICM/ELL PERMIT APPLICATION Parcel I.D. 05066208000 Property owner(s) Dean Construction & Development Day phone Mailing address 22222 ELKHORN CIRCLE Eagle River, AK 99577 Site address fir` Hiland Rd Eagle River AK Legal description (Sub'd., Block & Lot) SUN VALLEY NORTH BLK 4 LT 8 Legal description (Township, Range & Section) Lot Size 155,604 Sq. Ft. Number of Bedrooms 4 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (N all that apply) Absorption Field 0 Initial 0 Single Family (SF) 0 Septic Tank El Upgrade El(w/wo ADU) Holding Tank El Renewal❑ (D) E]Renewal Privy ❑ Multiple Dwellings ❑ (SF and/or D) Private Well 0 Water Storage ❑ THIS APPLICATION INCLUDES A WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Mun"cippl Codes. (Signature of property owner or authorized e(gent) Permit/Rush Fees: it 8*90 Date of Payment: —)a b 09 D Receipt Number: IS 5tb Permit No. O SPa0,l :111 Waiver Fees: Date of Payment: Receipt Number: Waiver No. GADevelopment Services\Building Safety\On Site Water and Wastewater\Forms\Client FormsTermit Application.doc Eklutna Engineering, LLC curtistownsend @gma i l.com July t,2022 Subject: Sun Valley North Block 4 Lot 8 New Septic System Permit Request osP22t2L7 I am writing to request a septic system installation permit for the above referenced property. The proposed system will serve a future 4-bedroom single-family residence. Soil logs, design calculations, site plan and design drawings are enclosed for your review. L. Soils. In May 2022 a test hole was dug to a depth of t2'.In June no groundwater presented itself in the test hole. The adjusted seasonalgroundwater elevation for the month of June would be 11'. The percolation rate was < 1 mpi. 2. Soil Absorption System Design. See Sheet 2 of the design package. 3. Wells. A new private water well will be drilled on this lot. Neighboring properties are served by private water wells. All neighboring water wells are > 100' from the subject property septic system. 4. Neighboring Wastewater systems. lmmediate neighboring septic systems are all +10' distant from the property lines. 5. Surface Water: There is no surface water within 100 feet of the proposed septic tank and drain field. 5. Topography: The property in the immediate area of the new trench has a slope of 32%. ' The criteria of 15.65.210 B.1.d can't be met, as the field draining the house is less than 50' up-gradient from the 32% slope. The 'steep slope' provisions of this code will apply. Construction of the septic system will meet all the conditions of L5.65.210 B.4.a i, ii, iv. 15.65.210 B.4.a iii will apply to this case and all existing vegetation on the 32% slope will remain intact. The slopes will not be disturbed. 15.65.210 B.4.a.v The disposal field is greater than 100' up-gradient from any 46% slope. As shown on sheet 4 of the design package, a line of 46% slope starting at 2.5' above the invert of the perforated pipe does not daylight the existing ground for at least 35'. The proposed installation will not affect the future development of this or the surrounding lots. Sincerely, Curtis L. Townsend, P.E. Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP221217, Deb Wockenfuss, 07/01/22 bro V./\ SEPTIc AREA \ \ \ \ \ \ \1 WATER WILL lS > 100' 1 FROM PROPERTY LINE \tot 6 "oq WAI FRC \ o -J--to z on a C) on \ I It\\\ \ \ \ \ U' rot .T( L( ,Tlc fq EP \\\\ U \r\.rrr. AREA DRILL WATER WELL > 1OO' FROM SEPTIC AREA ON LOT 3'uD; \ \ Septic Design Prepored for Dean Construction & Development Itll1t# Hiland Road Eagle River, Alaska gg|77 SUN VALLEY NORTH BLOCK 4 LOT 8 osP221217 TKLUTNA [NG/N[IR/NG, LLC 19162 MOUNTAIN ROAD CHUGIAK, ALASKA 99567(s07) 406- 1 OsB DATE: 711t2022 DRAWN: CLT SCALE: 1" = 100' PID: 050€62-08 SHEET 1OF 4 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP221217, Deb Wockenfuss, 07/01/22 bro V./\ SEPTIc AREA \ \ \ \ \ \ \1 WATER WILL lS > 100' 1 FROM PROPERTY LINE \tot 6 "oq WAI FRC \ o -J--to z on a C) on \ I It\\\ \ \ \ \ U' rot .T( L( ,Tlc fq EP \\\\ U \r\.rrr. AREA DRILL WATER WELL > 1OO' FROM SEPTIC AREA ON LOT 3'uD; \ \ Septic Design Prepored for Dean Construction & Development Itll1t# Hiland Road Eagle River, Alaska gg|77 SUN VALLEY NORTH BLOCK 4 LOT 8 osP221217 TKLUTNA [NG/N[IR/NG, LLC 19162 MOUNTAIN ROAD CHUGIAK, ALASKA 99567(s07) 406- 1 OsB DATE: 711t2022 DRAWN: CLT SCALE: 1" = 100' PID: 050€62-08 SHEET 1OF 4 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP221217, Deb Wockenfuss, 07/01/22 SCOPE OF WORK1. THIS LOT WILL BT DTVILOPI SEPTIC AND THEN SOLD. TF LANDOWNER WOULD THEN C 2. PLACE NEW 1,500 GALLON TANK WITH ORENCO AX2O I POD AND TIE INTO ABSORP PROVIDE LIFT STATION VAUL DISTRIBUTION PIPING ORIFIC @ x 2' SPACING.3. ALL CONSTRUCTION TO BT I ALL RIQUIRTMENTS SPECIFIE MUNICIPAL CODE CHAPTERS 4. FUTURE HOME FOUNDATION CONSTRUCTED A MINIMUM O FAP TANK. IPROPOSED WELL DESIGN PARAMETERS BEDROOM: 4 (600 cPD) SOIL PERCOLATION RATE: < 1 PROPOSTD CATEGORY III APPLI AREA RIQUIRED: 100 SF / svsrrv TYPE: SHALLow rREN, I/ 20' x 5' x 6'EFFECTIVE DEPTH ' MAXIMUTu DEPTH oF SEWER Rc PROVIDE 2' SAND LAYER BELO -D WITH A WELL AND E FUTURE ONSTRUCT A HOUSE. TWO-COMPARTMENT .DVANTEX FILTER tION SYSTE|'/. T WITH 2" E SIZING rO BE 1/8" N ACCORDANCE WITH D IN ANCHORAGE 15.55 AND 15.65. IS TO BT F 10, AWAY FROIV mpl CATION RATE: ]H YIELDS 100 sf ICK TO BE 6'. W SEWER ROCK. -DCO FUTURE 4 BEDROOM HOME LIFT STATION /-----,./\ N/T \ \ I I I RTSER CONST FROIV IUCTED IVIN 6, AWAY NEW' TRENCH Septic Design Prepored for Dean Construction & Development #ttlt# Hiland Road Eagle River, Alaska 99577 SUN VALLEY NORTH BLOCK 4 LOT 8 osP221217 EKLUTNA ENG/N[[R/NG, LLC 19162 N/OUNTAIN ROAD CHUGIAK, ALASKA 99567 (s07) 406- 1 058 DATE: 71112022 DRAWN: CLT SCALE: 1" = 30' PID: 050€62-08 SHEET 2 OF 4 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP221217, Deb Wockenfuss, 07/01/22 PROFILE VIEW A-A 1. EXISTING GROUND ALONG THIS PROFILE LINE IS APPROXIN/ATELY 32%. SLOPE DOWN GRADIENT OF THE SEPTIC TRENCHES WILL NOT BE DISTURBED. ALL EXISTING VEGETATION ON IT WILL BE LEFT IN PLACE N/EET 15 65.210 8.4 o.iii2. SOILS IN THIS ARTA HAVE A PERCOLATION RATE OF < 1 IVPI. 3. AN IMAGINARY LINE DRAWN AT 46% SLOPE, 2.5' ABOVE INVERT OF DISTRIBUTION PIPE DOES NOT INTERSECT SLOPE OF EXISTING GROUND FOR AT LTAST J5,.+. THE TRENCH t'/IETS 15.65.210 B.4.o.v' TO FUTURE RTSERVE TRENCH 6, AWAY ORGANICS rn 46% SLOPE EXISTING GROUND IS APPROXIMATELY 32% Septic Design Prepcred for Dean Construction & Development ### Hiland Road Eagle River, Alaska 99577 SUN VALLEY NORTH BLOCK 4 LOT 8 osP221217 EKLUTNA ING/NIIRING, LLC 1 91 62 lvl0 U NTAIN ROAD CHUGIAK, ALASKA 99567 (e07) 406 1 0sB DATE: 612112022 DRAWN: CLT SCALE: 1" = 10' PID: 050-662-08 SHEET 4 OF 4 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP221217, Deb Wockenfuss, 07/01/22 SOILS LOG -PERCOLATON l I I TEST 1 2 3 4 5 6 f 8 J 10 1'r 12 ORGANICS ----- nATtr ptrRtrnRN/rn. 5 /31 /tAt) WAS GROUND WATER ENCOUNTERED? NO DEPTH TO WATER AFTER MONITORING? NONE ^l.^/^^^^uAtL: o/ to/ zuzz WATER READTNGS ARE TO THE NEAREST 1/16 INCH. PERCOLATION RATE: < 1 MIN /INCH PERC HOLE DIAMETER: 6" TEST RUN BETWEEN 3 AND 4 FEET. PERFORMED BY: CURTIS TOWNSEND, I, CURTIS TOWNSEND, CERTIFY THAT THIS TTST WAS PERFORMED IN ACCORDANCE ALL STATE AND MUNICIPAL GUIDELINES lN EFFECT ON THIS DATE. DATE: 6/1/2022 FUTURE 4 BEDROOM HOIV E c) l z on U)a Un NO.DATE CLOCK TIME NET TIME IVIN WATER LEVEL READING 1 6 /O1 /2022 4:09 /14:14 5 b-uo 2 6 /O1 /2022 4:14/14 19 5 o-uo 3 6 /O1 /2022 4:20 /1 4 25 5 o -u o /6 /O1 /2022 4:27 /1 4:32 5 c)-uo Septic Design PrePcred for Dean Construction & Development ### Hiland Road Eagle River, Alaska 99577 SUN VALLEY NORTH BLOCK 4 LOT 8 osP221217 TKLUTNA tNG/NttR/NG, LLC 19162 IVOUNTA]N ROAD CHUGIAK, ALASKA 99567 (e07) 406- 1 OsB DATE: 612112022 DRAWN: CLT SCALE: 1" =40' PID: 050-662-08 SHEET 3 OF 4 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP221217, Deb Wockenfuss, 07/01/22 MUNICIPALITY OF ANCHORAGE ADVANCED WASTEWATER TREATMENT SYSTEM MAINTENANCE AND REPAIR AGREEMENT THIS MAINTENANCE AND REPAIR AGREEMENT, herein the "AGREEMENT" made and entered into as of this Day of J 4 k .e of 20 a qby and between ,.herein the "OWNER," and the Municipality of Anchorage, herein the "MUNICIPALITY", in accordance with Anchorage Municipal Code (AMC) 15.65.365. In consideration of the mutual covenants contained herein, the parties to this Agreement agree as follows: 1. Advanced Wastewater Treatment Systems. The Municipality grants permission to the Owner to utilize and operate an Advanced Wastewater Treatment System (AWWTS), described as located at (legal description) r�4t VQ l !e 1 / A,a,r 74 15 2-a ,- ,n 2. Maintenance, Repairs and Alterations. (Owner is required to read, understand and initial each .section) Throughout the term of this Agreement, the Owner shall enter into a service agreement with'an AWWTS service and maintenance provider approved by the Municipality or the manufacturer's representative. The AWWTS shall be maintained in a satisfactory condition capable of performing as designed and producing treated septic effluent in accordance with the equipment's approval for operation in the Municipality. It shall be the responsibility of the Owner during the term of this Agreement to pay for all repair(s), maintenance, adjustment(s), replacement costs, and inspection costs. This includes an annual maintenance fee (typically $400 to $600). Owner agrees that only maintenance and repair personnel approved by the Municipality or the manufacturer's representative will inspect and make any necessary maintenance, repairs or permitted alterations to the system. Owner acknowledges that regular maintenance of an AWWTS reduces the potential failure of the system, which could include sewage backup and costly repairs or drainfield replacement. (rev. 05/18/2018) Page 1 of 3 7� Owner acknowledges that the Municipality may request records of maintenance and repairs from the manufacturer's representative or maintenance provider. Owner acknowledges that the fine for failing to maintain and repair an AWWTS may be assessed in accordance with AMC 14.60.030. Owner agrees to grant the Municipality reasonable access to test and inspect the AWWTS. The Municipality will give at least 24-hour notice. Owner agrees that any sale or transfer of title of the property will not occur without a new Certificate of On -Site Systems Approval. Owner agrees that the AWWTS installation and maintenance requirements as provided by the AWWTS vendor/installer and approved by the Municipality are the governing guidelines for the construction, maintenance and repair of the Owner's AWWTS. Owner agrees to maintain remote monitoring of the AWWTS as required by the AWWTS approval. 3. Term. The term of this Agreement shall begin on the date of approval by the Municipality to operate the installed system, or upon transfer of title, and shall continue while the AWWTS is operational or until title is transferred. 4. Nonwaiver. The failure of the Municipality at any time to enforce a.provision of this Agreement shall in no way constitute a waiver of the provisions, nor in any way affect the validity of the Agreement or any part hereof, or the right of the Municipality thereafter to enforce every provision hereof. 5. Amendment. This Agreement shall only be amended by authorized representatives of the Owner and Municipality. Any at to amend this agreement by either an unauthorized representative or unauthorized means shall be void. 6. Jurisdiction: Choice of Law. Any civil action arising from this Agreement shall be brought in the Superior Court for the Third Judicial District of the State of Alaska at Anchorage. The laws of the State of Alaska shall govern the rights and obligations of the parties under this Agreement. 7. Severability. Any provisions of this Agreement decreed invalid by a court of competent jurisdiction shall not invalidate the remaining provisions of the Agreement. (rev. 05/18/2018) Page 2 of 3 OWNER: ), By: (signature) (print name) STATE OF ALASKA ) ) ss. THIRD JUDICIAL DISTRICT ) Date: 6 --.7 ---7 -;:70 The foregoin instrument was acknowledged before me this day o , 20QD-, by \ -ec,� N\\\\PIG Y IC FOR ALASKA •_N 'oc� My Commission expires: ems. /� aya3 — OT CP Lie MUNICIPALITY: BY / (signature) (print name) (rev. 05/18/2018) Date: 6 Z Z 22 Title: Page 3 of 3 MUNICIPALITY OF ANCHORAGE Development Services DepartmentPhone: (907)343-7904 On -Site Water & Wastewater Section Fax: (907)343-7997 Parcel ID 050 -662-08 Certificate of On -Site Systems Approval OSC251206 Expiration Date: 5/16/2026 Legal description SUN VALLEY NORTH BLK 4 LT 8 Site address Current property owner(s) STREFF JOSIAH X The On-site system(s) is/are approved for 4 bedrooms By: Conditional approval for bedrooms, with the following stipulations: Comments or conditions: 1. Final grading around tankage 2. clean out filter sand from monitoring tubes 3. swing ties from structures to septic features 4. electrical connections of the AWWTS and startup Original Certificate Date: 5/30/2025 /h' ificate of On -Site Systems Approval (COSA) is intended to demonstrate the subject (s) is/are in substantial compliance with municipal code. The Municipality of Anchorage, pment Service Department (DSD) issues COSAs based upon representations provided by an independent professional engineer. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's submittal. ATTACHMENTS: COSA Checklist X Well Flow Advisory Absorption Field Advisory Nitrate Advisory Tank Age Advisory Arsenic Advisory Other MUNICIPALITY OF ANCHORAGE 5 Development Services Department Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Certificate of On -Site Systems Approval Application 1. GENERAL INFORMATION Parcel I.D. 050-662-08 Complete legal description Sun Valley North Block 4 Lot 8 Location (site address) NHN Hiland Road Ea_gle River Current property owner(s) Joshiah Streff 2. ON-SITE SYSTEMS SIZED FOR 4 BEDROOMS Day phone 3. TYPE OF WATER SUPPLY: ❑Q Private Well serving # i* dwelling units * No dwellings currently ❑ Other Non-public well as regulated by MOA ❑ Water Storage ❑ Community Well or Public 4. TYPE OF WASTEWATER DISPOSAL: F0 Private Septic ❑ Private Septic serving 2 dwelling units ❑ Holding Tank ❑ Community Septic or Public Sewer 5. SEPTIC TANK: ❑ Steel n Plastic ❑ Concrete ❑ Fiberglass Age 3 - See advisory if steel or fiberglass older than 20 years 6. ABSORPTION FIELD: Q AWWTS ❑ Bed ❑ Deep Trench R Wide Trench ❑ Seepage Pit Waiver request for: Expedited review requested: ❑ Distance: By applying for this entitlement, this property is subject to inspection by municipal On-site staff to verify the accuracy of the information provided. COSA Fee $ _7 Date of Payment '5-11A o'� COSA # C0 S C-9 5-I ?10 b Waiver Fee $ Date of Payment Waiver # COSA ApphcaGon_Ap2025.doc COSA Checklist Legal Description: Sun Vallev North Block 4 Lot 8 Parcel ID: 050-662-08 If more than 1 well and/or septic system on lot, provide separate checklist. Structure served by this system A. WELL DATA 0 Well log is filed with Onsite (or attached) Date drilled 7/11/22 Total depth 121 ft Cased to 121 ft ❑✓ Sanitary seal is functioning correctly ✓❑ Wires are properly protected Casing height (above ground) 36 in. Date of flow test for COSA New Well Static water level at beginning of test 37 ft. Comments B. TANK DATA Measured operating fluid level in septic tank New Date of pumping New install 7/16/22 ❑ Required maintenance completed, if AWWTS Comments: D. DISPOSAL FIELD DATA Which system tested (date installed) 7116/22 0 ALL standpipes present per record drawing Total measured depth from grade 5.9 ft (max) Measured depth to pipe invert from grade ft (min) ✓❑ N/A — pressurized field. ❑ Per record drawings, field is insulated. ✓❑ Monitor tubes go to bottom of effective. If not, state depth into effective ❑ Presoaked required if (Required if house vacant or field not used for more than 30 days prior to date of test) Gallons introduced gallons date Any rejuvenation treatment (past 12 months) If yes, enter date Comments/Def ciencies COSA Cheddist_May2025.docx Well production at time of test 40+x gpm Water storage tank volume None gallons Well disinfected for coliform test? ❑ Yes 0 No 0 Coliform bacteria is Negative Nitrate mg/L Nitrate less than MRL (ND) Arsenic ug/L © Arsenic less than MRL (ND) Collected by Arcterra Consulting _ Date 5/16/25 C. LIFT STATION ❑ Required maintenance completed Age of lift station 3 years Lift station material Plastic Comments: New install Adequacy test date New install Results ❑, Pass Fluid depth prior to test in Water added gal New fluid depth in Elapsed time min Final fluid depth in Absorption rate gpd FIELD STATUS — POST RECOVERY Effective depth (per record drawings) Effective depth used in Effective depth remaining in in E. SEPARATION DISTANCES From Well on Lot to: (Please enter distances if less than required) Septic Tank/Lift Station on Lot > 100' 0 Yes if No ft Sewer Manhole/Cleanout 100' Yes if No ft ✓❑ Yes if No ft _> ✓❑ Yes if No ft Neighboring Tank > 100' [Z Yes if No ft Sewer Service/Septic Line > 25'Z Yes if No ft Disposal Field on Lot > 100' 0 Yes if No ft Holding Tank > 100' ✓❑ Yes if No ft Neighboring Disposal Fields > 100' Animal Containment > 50' ✓❑ Yes if No ft ✓❑ Yes if No ft Manure/Animal Excreta Storage > 100' Sewer Line/Main > 100' 0 Yes if No ft 0 Yes if No ft ❑ N/A — Served by Community Well (not on lot) or Public Water From Septic/Holding Tank and Disposal Field(s) on Lot to: (Please enter distances if less than required) Tank to Foundation > 10' ✓❑ Yes if No ft Surface Water > 100' 0 Yes if No ft Field to Foundation > 10' 0 Yes if No ** ft Tank to Property Line > 5' 0 Yes if No ft Field to Property Line > 10'✓❑ Yes if No ft Water Main/Service Line > 10' 0 Yes if No ft F. ENGINEER'S COMMENTS ** No foundation at time of this COSA Wells on Adjacent Lots: Wells > 100' ✓❑ Yes if No ft Community Wells > 200' 0 Yes if No ft If tank or field is under driveway comment below G. CERTIFICATION & STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines, indicates that the on-site water supply and/or wastewater disposal system appears to comply with applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation, unless noted otherwise. Name of Firm Arcterra Consulting Phone (907)-696-6111 Engineer's Printed Name Kenneth Duffus Date L x3 .� Engineer's Comments: This investigation was completed in compliance with ADEC and MOA regulations. The assessment of the condition of the well and septic applies only to the day OF conditions as of the tested. The flow and absorption rates may change due to subsurface conditions that may not be from the inland local ��~+E observed surface, changes use, soil characteristics, groundwater levels that may fluctuate during the year and the water &F is usage of the family being served by the system. The operational life of all well and septic 49 systems are subject to these various and dynamic characteristics and are outside the control of the evaluator of the well and septic system. Therefore, ArcTerra can not give any estimate of how long a system will function satisfactory for current or future occupants KENNETH a U5 f Z w or can ArcTerra guarantee that no unseen encroachments, deficiencies or discrepancies i CN exist. 'Wei ��+� COSA Checklist_May2025.docx stM%*