Loading...
HomeMy WebLinkAboutPALATERRA ADDN 2 LT 5Onsite File Palaterra Addn 2 Lot 5 #017-151-29 tr,ev uDicu iuf Municipality of Anchorage On -Site Water and Wastewater Section • (907) 343-7904 Page 1 of ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP231233 PID Number: 017-151-29 Dwelling:■❑ Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: 9 New ❑ Upgrade Name Colony Builders Inc ABSORPTION FIELD ❑ Deep Trench 9 Wide Trench ❑ Bed ❑ Mound Site Address 13493 De Palatis Cir ❑ Other Phone Number of Bedrooms Soil Rating depth from original grade (907) 345-0371 Four(4) 4 GPD/SF JTotal 2.0 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade 2,0 Ft. Gravel depth beneath pipe 0.5 Ft. Subdivision Block Lot Palaterra Addn 2 5 Fill added above original grade 1.5 Ft. Gravel length 30 Ft. Township Range Section Gravel width 5 Ft. Beds: Number of Lines N/A Distance between lines N/A Ft. SEPARATION DISTANCES To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Tank Line 150 Ft2 1 N/A Ft. Well >50' >50' N/A N/A >25' TANK ❑ Septic ❑ S.T.E.P. ❑ Holding ❑ Other Manufacturer Anchorage Tank (Advantex) Capacity 1,500 Gal. Surface Water >50' >50' N/A N/A Material Steel Number of compartments 2 Lot Line >5'E>51N/A N/A NA Foundation >1Q' N/A N/A LIFT STATION Manufacturer Orenco Capacity 250 Gal. Remarks Field is insulated Alarm location Corner of House Electrical installed by Installer PIPE MATERIAL House to tank D3034 Tank to D3034 drainfield A+ Home Services Drainfield D3034 CO/MTD3034 Inspector B• Schiller BENCH MARK (Assumed elevation) 1 OO ft Inspect 15` 8/11/23 8/11/23 Location and description sn Zed Front Door Threshold 3rd 8/12/23 4th ON-SITE WATER AND WASTEWATER SECTION APPROVAL Engineer's Stamp Conditional Approval: Date ��Q' ! ..0, . J co 49TM •* %chiller Septic System Approved Date�slF C1 `,/321 Benjam�r �'FG, • , CE 12592 , • c�`��/ • , ,8/30/23 , •'�C�� ll�\ pROfE5S104� Note: this approval does not include well permit requiremen s. tr,ev uDicu iuf Benjamin Schiller CE 12592R E GISTEREDPROFES S I O N A L E N GINEER 1"=50' 30' LONG x 5' WIDE, 6" EFFECTIVE DEPTH ABSORPTION TRENCH 1500-GAL ADVANTEX TANK W/ AX20 POD AND PUMP VAULT CO - CLEANOUT FCO - FOUNDATION CLEANOUT POD - AX-20 POD MH - MANHOLE PV - PUMP VAULT MT - MONITORING TUBE SV - SEPTIC VENT TH - TEST HOLE LEGEND TP5 PERMIT # OSP231233 PID # 017-151-29 PALATERRA ADDN 2, LOT 5 A B FCO 15.2 POD 19.6 MH1 15.3 A B MH2 21.9 PV 24.9 MT1 37.4 MT2 46.5 7.7 16.5 17.4 23.3 25.8 40.2 33.5 9/04/23 FEET 0 50 100 FCO DE P A L A T I S 4-BDRM HOME 870 880 860 890 900 910 TP4 TP6 CI R C L E TOP OF STEEP SLOPE 10' UTILITY EASEMENTS 100' SETBACK FROM STEEP SLOPE P5 P6 P4 MT1 PROPOSED HOME PRO P O S E D H O M E EXISTING WELL MT2 TH1 PLAN AS-BUILT BENCHMARK ALTERNATE SITE EXTENT OF COVER PV MH1 MH2 POD PROFILE AS-BUILT (NO SCALE) 91.5 83.8 92.0 97.3 AX-20 POD AND MANHOLES 1500 GAL SEPTIC TANK 98.8 FINISH GRADE 30' DRAINFIELD ROCK MT 1 TH # 1 GROUNDWATER AT 90.3 ON 7/28/23 95.3 82.8 95.3 97.3 ORIGINAL GRADE MT 2 Benjamin Schiller CE 12592 R E GISTEREDPROFES S I O N A L E N GINEER 9/04/23 PERMIT # OSP231233 PID # 017-151-29 PALATERRA ADDN 2, LOT 5 97.897.8 97.7 PUMP VAULT 95.8 97.9 INSULATION NOTE: GRAVEL FILL LAYER IN TEST HOLE WAS NOT FOUND IN TRENCH EXCAVATION- NO SAND LAYER WAS NEEDED LEGAL DESCRIPTION: PERFORMED FOR: DATE: PARCEL ID#: SOILS LOG AND PERCOLATION TEST TECHNICIAN: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 DEPTH (feet) PROJECT No.: TEST HOLE 1 SLOPE SLOPE SITE PLAN DATE READING Time(minutes) DEPTH toWATER NET DROP PERC. HOLE DIA. (INCHES)PERCOLATION RATE: (MIN/INCH) TEST RUN BETWEEN: FT. and FT. COMMENTS: (inches)(inches) B. Schiller DATE OF MONITORING: WAS GROUND WATER ENCOUNTERED? DEPTH TO WATER AFTER MONITORING: IF YES @ WHAT DEPTH?- 4.7 6 4 5 7/14 1 2 3 4 5 6 SM (SILTY SAND) Professional Engineers Stamp: NO 7.0' 7/28/23 Palaterra Addn 2, Lot 5 7/14/23 017-151-29 Colony Builders 24:151 2 3 4 5 6 11 2 16 1' OB Benjamin Schiller CE 12592 R E GISTEREDPROFE S S I O N A L E N GINEER July 30, 2023 GM (GRAVEL FILL) PERC TEST LOCATION 5 2 16 7 10 165 2 16 7 8 165 2 16 7 6 165 2 16 7 4 165 1 16 6 14 164 12 16 6 2 10 16 2 6 16 2 4 16 2 3 16 2 2 16 DEPTH toWATER(inches) 10:00 10:00 10:00 10:00 10:00 SliVlbdaa 0 Oil 0. I �C3 Ln as U. U Z H Ld Cl w o a � - r- 0– ` m m Y c m p ID m m `0 E 06 m t '> Q 0.0 m 0 • m O c 10 r N= 0 a CD CD Ul0 a O N N I �' I N 0 >.� � oz m a� N E o 0 m 11 I cros� c L a�> am I m o H m .m L 0 = I N v CD E_ d m ID z m m � o CIL =o Q t "E I aa E m c C 0 PI m W U 7 N w 0 IpNCDGa I U)ca- 0^OL o Aa a.10 �10 usocca o m—°t W J Q U N X1 _J a m V) Q z 0- 0 0 U V) L. _ O O J V! c •V) N c�- c 0 OIL J La os U U W a a N N a a 0 m a m I�Gj` ' : d�lp }� y • 6 Ln as U. � m a m I 0' w z m m � o CIL =o Q t "E I aa E m c C 0 PI m W U 7 N w 0 IpNCDGa I U)ca- 0^OL o Aa a.10 �10 usocca o m—°t W J Q U N X1 _J a m V) Q z 0- 0 0 U V) L. _ O O J V! c •V) N c�- c 0 OIL J La os U U W a a N N a a 0 m a m a � m a N a o a r- 0– ` m m rn p c m p ID m m `0 E 06 m t '> Q 0.0 m 0 • m O c 10 r N= 0 a CD CD Ul0 a O N N I �' I N 0 >.� � oz m a� N E o 0 m 11 I cros� c L a�> am I m o H m .m L 0 = I N v CD E_ d m -0 C14o h � rn m C� _t c=am I I c m o 0} uEi ���ozosmam E`a U V L OID o� t D U �I e a vL�hv a � ma .0 p C a C p t Q m rn 3 N o 0 c�a I I 0 0 °0 �c L ID –>. »- >.c z L -.r I - m o c'D o y- -< '0 a in x m }` 0 0 E m > o o i 0 c — C m L.a -E LJ5 t H H I m D a r c Q m O 0-0 a maO:aEco 0 a L mo V m m> a N � N N L- N a+�- L- cC N ID a m po G -Em m t U m N Hm > _ Q3cam o ;cos Alpine Drilling Permit Number: #SW221247 Date of Issue; 7-6-22 Parcel Identificatiou Number, 01715129= Date Started: 5-1C? 2323 mate Completed,- 55-16-23-23 is well located. at approved permit location? x Yes ❑ Nc Legal Description: Pulaterra Addition 2Lot 5 Property Owner Name S Address: Colony Builders, Inc. 8420 Vanguard Unit A Anchors e, Alaska 9,9507 Borehole Data: Depth (ft) Method of Drilian x a Sail T}rpe, Tllicktness & W,, ter Strata. From TO g air rota rY ❑cable tool Casing type: ,steel Null Thicl tress:.250 hiohes Diameter: 6 inches Depth: 270 feet Liner Type, steel Dian'ieter: 4 inches Depth: 14 to 330 feet Casing stickup above ground: 2 feet Static water level (from ground level): 201 feet Pumping level: 330 feet after 2 hours pumping 15 gpin Recovery Rate: 15 gpin Method of Testing: air li Well Intake Opening Type: x Open End ❑ open Dole ❑ Screened Start feet Stopped feet ❑ Perforat"Is Start feet Stopped feet Grout Type; beiat Hite anrrles Volume: 11 De tl : S rt 0 feet o ed ?feet Pump:1_ntake Depth feet Pump size $p Brand Name Well Disinfected Upon Completion? x Yes ❑ No Method of Disinfection.: chlorine t„ahlett' Comments: Well Driller: Alpine trilling &.Ejtterin'iscs ,PO BOa: 110495 Anchorage ,4.,li 99511 stick-up sand ravel fill sanely silt sandy silt 'Tilt gravelly szlhPlUdfs silt gravelly silt h1drrs silt grey gral,elly silt gj�ey ivater sand & gravel 0 2 2 6 5 24 24 40 40 .136 136 240 240 255 255 285 285 281 28,1 325 325 330 MUNICIPALITY OF ANCHORAGE Development Services Department Phone: 907-343-7904 On-Site Water & Wastewater Section Fax: 907-343-7997 Pump Installation Log Well Drilling Permit Number: _______________ Date of Issue: ____-____-____ Parcel Identification Number: ____-____-____ Legal Description Block Lot Property Owner Name & Address: Pump Installation Date: _____-_____-_____ Pump Intake Depth Below Top of Well Casing: __________ feet Pump Manufacturer’s Name: ___________________________ Pump Model: _____________________________________ Pump Size: ____________hp Pitless Adapter Burial Depth: _________ feet Pitless Adapter Manufacturer’s Name: _________________________ Pitless Adapter Installer: ____________________________ Well Disinfected Upon Completion?;;<HV No Method of Disinfection: _____________________________ Comments: Pump Installer Name: __________________________________ Company: ___________________________________________ Mailing Address: ______________________________________ City: ___________________ State: __________Zip: _________ Attention: The pump installer shall provide a pump installation log to On-site within 30 days of pump installation. 017 151 29 PALATERRA ADDN 2 5 COLONY BUILDERS INC 9420 VANGUARD DRIVE #1 ANCHORAGE, AL 99503 06 06 2023 300 GOULDS 12S18 1.50 15 MARTINSON PELLETS ANCHORAGE WELL & PUMP SERVICE 7640 KING STREET ANCHORAGE AK 99518 MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program' PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Water & Wastewater System Permit Permit Number: OSP231233 Work Type: WellSeptic Renewal Tax Code Number: 01715129000 Site Legal Address: PALATERRA ADDN 2 LT 5 G:2939 Site Mailing Address: 13493 DE PALATIS CIR, Anchorage Owner: COLONY BUILDERS INC Design Engineer: FORGE ENG This permit is for the construction of: Effective Date: Expiration Date: Lot Size in Sq Ft: Total Bedrooms: 7/28/2023 7/27/2024 101864 Q Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy 0 Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing 4 Special Provisions: • A test hole is required prior to construction of the absorption field, in the location shown on the site plan, to }{ confirm minimum separation to impermeable soil and seasonal high groundwater, as well as percolation rate. Construction may proceed at your own risk prior to 7 -day groundwater monitoring. If results require i+ a design change, construction shall stop pending approval of a change order. Please submit results with the inspection report (or change order, if required). J CO OL GRAf-l�e­D S/z,C- vf= Tf 2f,,i, �: TSS(AP�� �U �o/OI nal Issued By: Date: Date: .712 MUNICIPALITY OF /ANCHORAGE 0r ;ice Community Development Department Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On -Site Water & Wastewater Program ON-SITE SEWER/WELL PERMIT APPLICATION' 4 Parcel I.D. 017-151-29 Property owner(s) Colony Builders Inc Day phone (907) 345-0371 Mailing address 9420 Vanguard Drive #A, Anchorage, AK 99503 Site address 13493 De Palatis Circle Legal description (Sub'd., Block & Lot) Palaterra Addn 2, Lot 5 Legal description (Township, Range & Section) Lot Size 101,864 Sq. Ft. Number of Bedrooms 4 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (® all that apply) Absorption Field ❑X Initial ❑ Single Family (SF) ❑X Septic Tank ❑X Upgrade ❑ (w/wo AD U) Holding Tank ❑ Renewal ❑X Duplex (D) ❑ Privy ❑ Multiple Dwellings ❑ (SF and/or D) Private Well ❑X Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: 2-S2 Waiver Fees: Date of Payment: Receipt Number: Date of Payment: Receipt Number: Permit No. 0 3P Z312_33 Waiver No. Permit App_:;- : ,'-.,:c July 28, 2023 MOA Development Services, On-Site Water & Wastewater Program 4700 Elmore Rd Anchorage, AK 99507 Subject: Palaterra Addn 2 Lot 5 – 13493 De Palatis Cir Septic System Permit Renewal Dear On-Site Services Engineer: The permit (OSP221247) for the construction of a well and septic system on the subject property has expired. A site visit was conducted, and while the home is in the process of construction, there are no substantial changes to the design or location of the septic system since this permit was originally issued. The well has been installed, and we have confirmed 50’ separation to the septic site for the tank and field. We will be finalizing the new confirmation test hole and the installer is looking to begin next week. We request a permit renewal. Sincerely, Benjamin Schiller, PE Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP231233, Deb Wockenfuss, 07/28/23 PALATERRA ADDN 2, LOT 5 Co-22-12 Co U / PROPOSED OSED WELLS W/ 50' P / \ LOT 3 / LLJ ® I \ 10' UTILITY EASEMENTS t` \ \ 1500-GAL ��,\ ALTERNATE SITE \ \ \ /A500-GAL TANK :- — \ W/ AX20 POD . AND PUMP VAUL) LOT 7 —� �,o '\ / 30'EFOFECTIVE D PTF+ TH1 , — _ \ _QQy�O/.' eP4 TP4 ABSORPTION TRENCH /QUO /., MAINTAIN 10' FROM MT FOUNDATION AND / PROPERTY LINE FCO \ • . , . AND 5' FROM SEPTIC, / , EXISTING WEE* / TANK �I', ► LOT 4 / �- BDRM HOME � _ _ _ - \ -•'' •';:...., � __ 900-- PROPOSED 00-PROPOSED HOME / O P5 TP5 i i/ 100' SETBACK FROM STEEP SLOPE LOT 5 • . P6 LOT 6 0 TP6 TOP OF STEEP SLOPE-- ---- . , .. , • ... --870 _. - ""� \ L-J�> GE _ _ E NG IN E E E ING NOTE, �1 NO SLOPES >25% WITHIN 50' OR SURFACE WATER WITHIN 100' OF THE LEGEND !�!C,9�111 PROPOSED SEPTIC SYSTEM CO -CLEANOUT *qg 7H �9*+I ALL WELLS ON SURROUNDING LOTS WITH IMPACTS TO THIS 2C0 -DOUBLE CLEANOUT / • ..••'• • • PROPERTY ARE SHOWN. NO CONFLICTS WITH WELLS OR SEPTIC FCO -FOUNDATION CLEANOUT SYSTEMS. FS - FLOW SPLITTER VALVE Benja• i Schiller / MH - MANHOLE �� �F'• CE 2592 •'��r 0 50 100 1c�slF 728/23 ,.•�c,��� FEET MT- MONITORING TUBE ESSIONp�SV - SEPTIC VENT PROF \���\ SS00�- 1 —50 TH - TEST HOLE PALATE RRA AD D N 2, LOT 5 G�Z DESIGN FACTORS: SYSTEM REQUIREMENTS: 600 GPD PEAK FLOW SHALLOW 5 -WIDE TRENCH SYSTEM PERK RATE: 4.7 MIN/IN 1,500 -GAL ADVANTEX TANK w/ AX -20 FILTER POD APPLICATION RATE: 4.0 GPD/SF AND PUMP VAULT (CONSERVATIVE) 600 GPD / 4.0 GPD/SF / 5' WIDE * 1[RED FACTOR] = 30 LF TRENCH REQUIRED (30 LF SPECIFIED) BOTTOM OF TRENCH: 2' BELOW GRADE FLOW LINE ELEVATION: 1.5' BELOW GRADE TOP OF TRENCH: 1' ABOVE GRADE PROVIDE ADDITIONAL FILL (6" MIN) TO ENSURE 2' MIN COVER AFTER SETTLEMENT 1' I I 2" INSULATION COY 5' GEOTEXTILE FABRIC DRAINFIELD ROCK 1.25" PVC w/ 20 x 8" ORIFICES EVENLY SPACED @ 1.5' OC (HOLES DOWN) MOA -APPROVED SAND TO RECEIVING SOILS (2.5' BELOW GRADE) TYPICAL TRENCH SECTION (NO SCALE) NOTES: 1. GRADE AREA OVER TRENCH TO DRAIN AWAY 2. PROVIDE T OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2' WITH 2" OF INSULATION 3. CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY �;` •�G.4���1 P••'' s1 rdj.. � y �1 • .m. .. �-� • .. • Benja•'n Schiller ' 1� �•. CE 12592 ••`moi �I c�sTF�Fo • 711, ans• . •�F\C'X �i\�,PROFESSIONP .�. Co ---'7'2. SOILS LOG AND PERCOLATION TES�T LEGAL DESCRIPTION: PALATERRA ADDN 2, LOT 5 PERFORMED FOR: COLONY BUILDERS DATE: 7114123 PROJECT No.: PARCEL ID#: 017-151-29 TECHNICIAN: B. SCHILLER DEPTH TEST HOLE 1 (feet) 1 2 3 4 1 1 1 2 COMMENTS: 1' OB GM (GRAVEL FILL) PERC TEST LOCATION SM (SILTY SAND) SLOPE WAS GROUND WATER ENCOUNTERED? NO IF YES @. WHAT DEPTH? - L TIME (MINUTES) DEPTH TO WATER AFTER MONITORING: 6.0' 0 NET DROP (INCHES) DATE OF MONITORING: 7/24/23 P 1 E 516 DATE READING TIME (MINUTES) DEPTH To WATER (INCHES) DEPTH To WATER (INCHES) NET DROP (INCHES) 7/14 1 24:15 516 116 6 2 10:00 516 7 16 216 3 10:00 51fi 7 16 216 4 10:00 516 716 2 s 5 10:00 516 716 21s 6 10:00 416 616 211 PERCOLATION RATE: 4.7 (MIN/INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN: 4 FT. and 5 FT. MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Water & Wastewater System Permit Permit Number: OSP221247 Work Type: WellSeptic Initial Tax Code Number: 01715129000 Site Legal Address: PALATERRA ADDN 2 LT 5 G:2939 Site Mailing Address: Owner: COLONY BUILDERS INC Design Engineer: FORGE ENGINEERING This permit is for the construction of: Effective Date Expiration Date: �rt�nt S c, lleln�rtment Lot Size in Sq Ft: Total Bedrooms: 7/6/2022 7/6/2023 101864 Q Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy 0 Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Special Provisions: • A test hole is required prior to construction of the absorption field, inthe location shown on the site plan, to confirm minimum separation toimpermeable soil and seasonal high groundwater, as well as percolation rate. Construction may proceed at your own risk prior to 7-daygroundwater monitoring. If results require a design change, constructionshall stop pending approval of a change order. Please submit results withthe inspection report (or change order, if required). Co -'_2Z 1 'Alnuld 41- S «I d Veronica Pope GE 2022.07.06 Received By: 14:44:42 -08'00' Issued By: Date: Date: 6 ZZ 4 I �I M �✓�� 1 UNICIPALITY OF ANCHORAGE Community Development Department Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On -Site Water & Wastewater Program ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 017-151-29 Property owner(s) Colony Builders Inc Day phone Mailing address 9420 Vanguard Drive #A, Anchorage, AK 99503 Site address NHN De Palatis Cir Legal description (Sub'd., Block & Lot) Palaterra Addn 2, Lot 5 Legal description (Township, Range & Section) Lot Size 101,864 Sq. Ft. Number of Bedrooms 4 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (® all that apply) Absorption Field ❑X Initial 0 Single Family (SF) IN Septic Tank INUpgrade 1-1(w/wo AD U) Holding Tank ❑ RenewalDuplex ❑ (D) El Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑X Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: l 3 Waiver Fees: Date of Payment: Date of Payment: Receipt Number: Receipt Number: Permit No. 0 S P a s `'� Waiver No. Permit App__- : , _.,:c July 5, 2022 MOA Development Services, On-Site Water & Wastewater Program 4700 Elmore Rd Anchorage, AK 99507 Subject: Palaterra Addn 2, Lot 5 – NHN De Palatis Cir Septic system design Dear On-Site Services Engineer: The owner of the above lot intends to build a 4-bedroom home on the property, so we are submitting this permit application for the construction of a new well and septic system. The attached site plan identifies the location of the home as well as the proposed well, septic location and alternate site. No conflicts exist between this proposed system and any other well or septic system, whether on this lot or adjacent lots. The ground surface on the lot slopes away from the road moderately in the front part of the lot, but drops off toward the back. It is in that flatter area that the new septic system is located. (There are no slopes greater than 25% within 50 feet downslope of either the primary or alternate site.) Stormwater drainage will not impact this septic system. The new trench will be constructed parallel to the slope as much as possible. Wells on this and adjacent lots are shown. The new system will be a minimum of 50’ from all wells and surface water, and more than 5’ away from the septic tank. The alternate site is located more than 16’ away. Please refer to the attached test hole logs, soils lab analysis, plan and profile pages for the septic design. If this design is followed, there will be no adverse impacts to adjacent properties. Sincerely, Benjamin Schiller, PE Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP221247, Deb Wockenfuss, 07/06/22 PALATERRA ADDN 2, LOT 5 \ -} PROPOSED WELLS IJ J / w/ 50�RADII LOT 3 / \ / W \ 20' LONG x T WIDE,1$' EFFECTIVE DEPH �� \ ABSORPTION TREN H �� 10' UTILITY EASEMENTS \ \ II ALTERNATE SITE \ \ CONFIRMATION \ TEST HOLE LOT 7 ca�0/ 0 P4 1500-GAL MT p� 0 TP4 ADVANTEX TANK W/ AX20 POD 2C / FCO 100' SETBACK FROM / / STEEP SLOPE — / - / LOT 4 / 4-BDRM HOME -~- 900-- PROPOSED HOME / O P5 0TP5 LOT 5 `r ----� � Ps LOT 6 Q5 TP6-880' TOP OF STEEP SLOPE%— \ -_ ENGINEERING NOTE: \� NO SLOPES >25% WITHIN 50' OR SURFACE WATER WITHIN 100' OF THE LEGEND k PROPOSED SEPTIC SYSTEM .•''•,�.��1�1 CO- CLEANOUT ALL WELLS ON SURROUNDING LOTS WITH IMPACTS TO THIS 2C0 -DOUBLE CLEANOUT . c�"• • • • • • • • PROPERTY ARE SHOWN. NO CONFLICTS WITH WELLS OR SEPTIC FCO -FOUNDATION CLEANOUT SYSTEMS. FS - FLOW SPLITTER VALVE / Benja i Schiller / MH - MANHOLE �+ �F� •. CE 2592 0 50 100 MT -MONITORING TUBE NIP* 7i5122 ..•FEET SV- SEPTIC VENT IiiW4 `� 1"=50' TH -TEST HOLE PALATERRA ADDN 2, LOT 5 TYPICAL TRENCH SECTION (NO SCALE) NOTES: 1. GRADE AREA OVER TRENCH TO DRAIN AWAY 2. PROVIDE 3' OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2' WITH 2" OF INSULATION 3. CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY Benjamin Schiller CE 12592R EGISTEREDPROFES S I O N ALENGINEER7/5/22 4" PERFORATED PVC (HOLES DOWN) DRAINFIELD ROCK 3' 6" 6" 4' 6" 8' DESIGN FACTORS:SYSTEM REQUIREMENTS: 600 GPD PEAK FLOW PERK RATE: 40 MIN/IN APPLICATION RATE: 2.0 GPD/SF 8' DEEP TRENCH SYSTEM 1,500-GAL ADVANTEX TANK w/ AX-20 FILTER POD BOTTOM OF TRENCH: 13' BELOW GRADE FLOW LINE ELEVATION: 5' BELOW GRADE TOP OF TRENCH: 6"' ABOVE GRADE 600 GPD / 2.0 GPD/SF / 8' DEEP / 2 SIDES = 18.8 LF TRENCH REQUIRED (20 LF SPECIFIED) Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP221247, Deb Wockenfuss, 07/06/22 Proposed Lot , Palaterra Subd. 14: /14: 1 /15: 15: /1 /10: 10: /14: 1 /1 1 /1 1 /1 1 /1 1 /1 24 /16 /16 /16 6 in. /16 /21 Proposed Lots 1-11, Palaterra Subd. / 5969-21 June 7, 2021 Colony Builders, Inc. No N/A None 1 Soak 2 3 4 6/7/21 30 30 30 30 0 Andrew C. Smith, CPG Keith F. Mobley, P.E. 6/ /21 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP221247, Deb Wockenfuss, 07/06/22 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP221247, Deb Wockenfuss, 07/06/22 MUNICIPALITY OF ANCHORAGE Development Services Department Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Parcel I.D. 017-151-29 Certificate of On -Site Systems Approval Expiration Date: I �Z 2� 2-3 Legal description PALATERRA ADDN 2 LT 5 Site address 13493 DE PALATIS CIR Anchorage AK Current property owner(s) COLONY BUILDERS INC X The On-site system(s) is/are approved for 4 bedrooms Conditional approval for bedrooms, with the following stipulations: Comments or advisories: Original Certificate Date: 9/12/2023 This Certificate of On -Site Systems Approval (COSA) is intended to demonstrate the subject system(s) is/are in substantial compliance with municipal code. The Municipality of Anchorage, Development Services Department (DSD) issues COSAs based upon representations provided by an independent professional engineer. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. ATTACHMENTS: COSA Checklist X Well Flow Advisory Absorption Field Advisory Nitrate Advisory Tank Age Advisory Arsenic Advisory Other COSA Approval—June 2022 MUNICIPALITY OF ANCHORAGE .; . Development Services Department r Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Certificate of On -Site Systems Approval Application 1. GENERAL INFORMATION Parcel I.D. 017-151-29 Complete legal description Palaterra Addn #2 Lot 5 Location (site address) 13493 De Palatis Circle, Anchorage, AK 99503 Current property owner(s) Colony Builders Inc Day phone (907) 345-0371 2. ON-SITE SYSTEMS SIZED FOR 4 BEDROOMS 3. TYPE OF WATER SUPPLY: ❑■ Private Well ❑ Private Well serving 2 dwelling units ❑ Private Well serving 3+ dwelling units ❑ Community Well or Public ❑ Water Storage 4. TYPE OF WASTEWATER DISPOSAL: 0 Private Septic ❑ Private Septic serving 2 dwelling units ❑ Holding Tank ❑ Community Septic or Public Sewer 5. SEPTIC TANK: 0 Steel ❑ Plastic ❑ Concrete ❑ Fiberglass Age < 1 yr - See advisory if steel older than 20 years 6. ABSORPTION FIELD: ❑ AWWTS [-]Bed ❑ Deep Trench ❑■ Wide Trench ❑ Seepage Pit Waiver request for: Expedited review requested: N. Distance: By applying for this entitlement, this property is subject to inspection by municipal On-site staff to verify the accuracy of the information provided. COSA Fee $ 120 Date of Payment J � �p � ?.CMZ I COSA# t 5c l 3 I&�(y Waiver Fee $ Z Z- i--1.35 Date of Payment Waiver # COSA Application—June 2022 Palaterra Addn #2 Lot 5 017-151-29 15 5/16/23 330 N/A 270 24 5/16/23 Forge Engineering 201 7/12/23 New Installation 8/11/23 3.5 3.5 N/A N/A N/A New Installation > Benjamin Schiller, P.E.9/4/23 6 (907) 522-7773 Joshua H. Haslett A. Haslet! (;7arint rutnte) STATE OF ALASKA THIRD JUDICIAL DISTRICT The foreg0in2) instrument was 2 0,'13 b` v Otd nate. _q h 1 12,3 1 1 5s. ledged before ine this day c�r�j}� JOCELYN HUNTING Notary Public /_ State of Alaska onunisslon expires: Qg Logs l�zMy Commission Expires Sep 2, 202669 mw INIUNICI ALITY i� 2- g�-; C% (signature) Date: � � Z V n�-t j �() wN lives (print name) Title: C t "/L C"' C ,:� 1