Loading...
HomeMy WebLinkAboutMOSSFLOWERWOODS LT 4Onsite File A 0 An mu— madolk m 4 HE Tor (Rev 05/02/18) Municipality of Anchorage On -Site Water and Wastewater Section - (907) 343-7904 Page 1 of 3 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP241028 PID Number: 015-141-77 Dwelling: FK Single Family (SF) 0 with ADU F-1 Duplex (D) Fj Two Single Family Project: 9 New El Upgrade Name Patrick Noblett ABSORPTION FIELD R Deep Trench ro-1 Wide Trench El Bed [:1 Mound Site Address 11145 Fireside Circle El Other Phonef Boil Soil Rating Total depth from original grade (907) 529-7702 7 7edrooms 1.2 GPD/SF 7.0 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade 3.0 Ft. Gravel depth beneath pipe 4.0 Ft. Subdivision Block Lot Mossflower Woods 4 Fill added above original grade 1.7 Ft. Gravel length 50 Ft. Township Range Section Gravel width 5 Ft. Beds: Number ber of Lines NIA Distance between lines N/A Ft. SEPARATION DISTANCES To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches 1 Dist. between trenches N/A From Tank Field Tank Line 500 Ft2 Ft. Well >100' >100' N/A N/A >25 TANK 9 Septic El S.T.E.P. El Holding El Other Manufacturer Greer Capacity 1250 Gal. Surface Water >100' > 100' N/A N/A Material Plastic Number of compartments 2 NA Lot Line >5' > N/A N/A Foundation >1 0' >1 0' N/A N/A LIFT STATION Ma er Capacity Gal. Remarks Alarm location I installed by PIPE MATERIAL House to tank D3034 drainfie[dTankto D3034 Installer Red Dog Masonry Drainfield D3034 CO/MT D3034 Inspector M. Jakubisin BENCH MARK (Assumed elevation) 100 ft Inspection 3/6/2024 3/7/2024 Location and description dates: 2 �d Bottom of Siding @ Point B 3°' 4"' ON-SITE WATER AND WASTEWATER SECTION APPROVAL Engineer's Stamp X Conditional Approval: Date AW, AK 497H KJ .w............... jan,'kry,§h % BenCE 1259c2iller 41 Septic Systen Approved Date 4/8/2024 AW PROFESSOW Note: this approvzl,,)Ps not include well permit requirements. (Rev 05/02/18) GE ENGINEERING PID # 015-141-77 LOT 20 50' LONG x 5' WIDE, 4' EFFECTIVE DEPTH ABSORPTION TRENCH ------------ -GAL SEPTIC TANK '0" MANWAY ------------- NEIGHBORING LOT WELL RADII LOT 20D E.Fr112th AVENUE A B C D (WALL) NEIGHBORING SEPTIC SYSTEM O f �a � - kkj ' `�►•9 FSCO 8.2 —_1..7 LEGEND MH g0 .r.. 3 62i CO - CLEANOUT Im.r 2CO 36.0 63.7 2CO-DOUBLE CLEANOUT FCO -FOUNDATION CLEANOUT MT1 1 C, t ' PLAN AS -BUILT Col Ho—T2. 73.8 � f ® Ii Ir' I '1 MH MANHOLE Benja i Schiller PF'• 0 50 100 CO2 78.9 GE ENGINEERING PID # 015-141-77 LOT 20 50' LONG x 5' WIDE, 4' EFFECTIVE DEPTH ABSORPTION TRENCH ------------ -GAL SEPTIC TANK '0" MANWAY ------------- NEIGHBORING LOT WELL RADII LOT 20D E.Fr112th AVENUE A B C D (WALL) NEIGHBORING SEPTIC SYSTEM O f �a � - kkj ' `�►•9 FSCO 8.2 —_1..7 LEGEND MH g0 .r.. 3 62i CO - CLEANOUT SP1••• � *� 49- :'k 2CO 36.0 63.7 2CO-DOUBLE CLEANOUT FCO -FOUNDATION CLEANOUT MT1 74.6 78.2 ' PLAN AS -BUILT Col Ho—T2. 73.8 77.4 FS - FLOW SPLITTER VALVE .. , •: • •/ 76.2 96.8 MH MANHOLE Benja i Schiller PF'• 0 50 100 CO2 78.9 102.9 - CE 2592 ���i °mss'•. 5r3o,z< ,. 'c,� FEET MT - MONITORING TUBE SV - SEPTIC VENT /'ROfESS10NP.!� 1 -51 TH -TEST HOLE MOSSFLOWER WOODS LOT 4 Nom 9 E NGIN� PID # 015-141-77 94.8 FINISH GRADE 93.1 ORIGINAL GRADE DRAINFIELD ROCK 86.1 NO GROUNDWATER 8/30/22 83.1 50' PROFILE AS -BUILT (NO SCALE) 86.1 N N O 90.1 *:49TM .. � -. . .......... ' • • Benja • ' Schiller CE 1 2592 Apnl6, 2024 PRO FESSIONP��.,"" Development Services Department �Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Well Log Permit Number: #osp2213jj Date of Issue: 9/23/22 Date Started: 7/31/23 Date Completed: $/3/23 Legal Description: Mossflowerwoods LT 4 G:2636 Property Owner Name & Address: Noblett Patrick Borehole Data: Depth (ft) Soil Type, Thickness & Water Strata From To Parcel Identification Number: Is well located at approved permit location? Yes ❑1 No ❑ casing stick up 0 2 Sand and gravel 2 22 Silty sand 22 43 Sand and gravel 43 68 Sandy silt and gravel 68 142 Boulder 142 149 Silt and gravel 149 165 Boney Silt and Gravel 165 186 Gray clay and gravel 186 198 ravel 198 210 gravel and gray clay 210 215 course gravel, moist 215 223 brown clay and gravel 223 229 moist gravel 229 235 brown clay and gravel 235 238 gravel and H2O 238 248 coarse gravel w/ H2O 248 252 Lat: 61.119674 Lon: -149.799086 Water Sample Results: Arsenic: NLn ug/L Nitrates: 2 ct I mg/L Total Coliform Bacteria: Y) '9— colonies/I00mL Method of Drilling 0 air rotary ❑ cable tool Casing type: Steel Wall Thickness: .25 inches Diameter: 6 inches Depth: 252 feet Liner Type: Diameter: inches Depth: feet Casing stickup above ground: 2 feet Static water level (from ground level): 210 feet Pumping level: feet after hours pumping ---pm Recovery Rate: 10 gpm Method of Testing: airlift Well Intake Opening Type: M Open End ❑ Open Hole ❑ Screened Start feet Stopped feet ❑ Perforations Start feet Stopped feet Urout type: bentonite volume: zoa95 Depth: Start feet Stopped feet Well Disinfected Upon Completion? Yes No Method of Disinfection: Tabs Comments: Well Driller: Johnny Kay Company: Hefty Drilling Inc. Mailing Address: Anch. AK, 99511 011111111111111V Attention: The well driller shall provide a well log to the On-site Water and Wastewater Section within 30 days of completion. a oo �UJ . ' p 4. a E7 v Z\/ '0111OVN PA 0 z m I U I n I I a 04° I N C14 m I a I m -- »- a --� I j II• 30.0' _ a .°c0 °c a ° c o m ® a; I n. w O m >. c» 1° rc°il w vo 9 N ) .pcm o 0 E VtO m °) 73 S 00'08'05"E 337.03' in 1 �om'Eh C ° .O �1 c >a m w a, N N 0) c >. 3 0 c 0 O C a 'oO (iJ Co r1� ® C 0- m O N *su V L V O at LLJwe o 01'.010 / \ m C3. GLd -i o6 t't O iv a E F m O` m O q C,4 I V O m OCC m O V) d f ` t t N a x i W / / V 0 Eft; O O m to t� 20.3' `L 74.9' \ < (— 0 .0 z - i � m !n 5 �. 414.0' 28.0' Od ti ( • _ (� a �° q m til p 3 20.5' Q o ° I `� � C~ d i E \,_ m O o 1 STORY N o !� �� y cavGma�"'+e� �,� 20 /RESIDENCE o r!}.- N w Vj 1_ ozf a a"` 0 m 0. N d b. 27.7" �i I Ja O .a v vi a m O a W` �� 0 1t.0' to M W� 00 +� � Q� 4)Vic0°oc m J ¢ N 7.2' ri 18.3' �3 W in -f— c%i ;� > a m a+ 3 at O o z ~ ' W Q1a0>.a �cn I W I •—� ��yc `a i m0 w Q XI U ® to a > m ,.- c z► `' I I Wav°��X ° o� zn ' n Q C3 v► 0 o m m o m s g2' R ,50':OQ. , I 33.0' / UI m O ° G ` ` >- o - �r m (j} >° 3 a a o t sCk: m m m CL I w w bN. ©lod / oOc G+G.a`}t 'moo •00 p � N '00'06"W 190.$9' �R v I 86 . >N°acc� 0• V1 tMW cLE c 0 oo ------- — — — — N — .z� AA'' m ds'` Y — .5 W V. m m j a q yt tm. a. O '����`0, s nt-a•-nm cc H ° FIRESIDE CIRCLE o �- U� � E o / a" .J Qat°coo o° =0 I MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Water & Wastewater System Permit Permit Number: OSP241028 Work Type: WellSeptic Renewal Tax Code Number: 01514177000 Site Legal Address: MOSSFLOWERWOODS LT 4 G:2636 Site Mailing Address: 11145 FIRESIDE CIR, Anchorage Owner: NOBLETT PATRICK Design Engineer: FORGE ENGINEERING This permit is for the construction of: Effective Date: Expiration Date: pent S _c w n Dehartnnent Lot Size in Sq Ft Total Bedrooms: 3/5/2024 3/5/2025 43641 Q Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well 0 Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Special Provisions: • The Record Drawing is to show the stormwater line. i 9eEeived-By: 55 e� -ho fOr e- /1 Date: Issued By: GjU Date: Z4-1 4 MUNICIPALITY OF ANCHORAGE 0 -'...� Community Development Department -- Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On -Site Water & Wastewater Program ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 015-141-77 Property owner(s) Patrick Noblett Mailing address 10618 Ketch Circle, Anchorage AK 99516 Site address 11145 Fireside Circle Day phone (907) 529-7702 Legal description (Sub'd., Block & Lot) Mossflower Woods, Lot 4 Legal description (Township, Range & Section) Lot Size 43,641 Sq. Ft. Number of Bedrooms 4 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (M all that apply) Absorption Field ❑X Initial ® Single Family (SF) ❑X Septic Tank ❑X Upgrade f-1(w/wo ADU) Holding Tank ElRenewal N1 Duplex (D) ❑ El Multiple Multiple Dwellings ElPrivy and/or D) Private Well ❑X Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. oci � i (Signature of property owner or authorized agent) Permit/Rush Fees: 12--; Z Waiver Fees: Date of Payment: Receipt Number: Permit No. Permit App_:;- : , �. c Date of Payment: Receipt Number: Waiver No. March 4, 2024 MOA Development Services, On-Site Water & Wastewater Program 4700 Elmore Rd Anchorage, AK 99507 Subject: Mossflower Woods Lot 4 Septic System Permit Renewal Dear On-Site Services Engineer: The permit for the construction of a well and septic system on Lot 4, Mossflower Woods Sub, has expired. A site visit was conducted and there have been no substantial changes to this lot or to the surrounding area since the permit was originally issued. The current design and permit conditions meet all code requirements. The proposed well location also meets the 100’ separation distance to the stormwater line on E 112th. We therefore request the renewal of the permit for the well and septic system on this lot. Sincerely, Benjamin Schiller, PE Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP241028, Deb Wockenfuss, 03/05/24 MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Water & Wastewater System Permit Permit Number: OSP221355 Work Type: WellSeptic Initial Tax Code Number: 01514177000 Site Legal Address: MOSSFLOWERWOODS LT 4 G:2636 Site Mailing Address: Owner: NOBLETT PATRICK Design Engineer: FORGE ENGINEERING This permit is for the construction of: Effective Date Expiration Date: Lot Size in Sq Ft: Total Bedrooms: �o�l»cnr �S f Department 9/23/2022 9/23/2023 43641 Q Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy Q Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Received By: Issued By: Date: Date: 9h 3/?' 4 MUNICIPALITY OF ANCHORAGE o� Community Development Department "' Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On -Site Water & Wastewater Program ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 015-141-77 Property owner(s) Patrick Noblett Mailing address 10618 Ketch Circle, Anchorage AK 99516 Site address NHN Fireside Circle Day phone Legal description (Sub'd., Block & Lot) Mossflower Woods, Lot 4 Legal description (Township, Range & Section) Lot Size 43,641 Sq. Ft. Number of Bedrooms 4 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (® all that apply) Absorption Field ❑X Initial 0 Single Family (SF) ❑X (w/wo ADU) Septic Tank 1ZUpgrade ElDuplex (D) F-1Holding Tank ElRenewal El Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑X Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: � 996, Date of Payment: '?/7/gA Receipt Number: 0111M ID Permit No. Al I? a a l 35S Permit App__- : ,..mac Waiver Fees: Date of Payment: Receipt Number: Waiver No. September 6, 2022 MOA Development Services, On-Site Water & Wastewater Program 4700 Elmore Rd Anchorage, AK 99507 Subject: Mossflower Woods, Lot 4 Septic system design Dear On-Site Services Engineer: The owner of the above lot intends to build a 4-bedroom home on the property, so we are submitting this permit application for the construction of a new well and septic system. The attached site plan identifies the location of the home as well as the proposed well, septic location and alternate site. No conflicts exist between this proposed system and any other well or septic system, whether on this lot or adjacent lots. The ground surface on the lot slopes moderately toward the road. There are no slopes greater than 25% within 50 feet downslope of either the primary or alternate site. Contours are shown on the site plan showing the grade and direction of flow. Stormwater drainage will not impact this septic system. The new trench will be constructed parallel to the slope as much as possible. Wells on this and adjacent lots are shown. The new system will be a minimum of 100’ from all wells and surface water, and more than 5’ away from the septic tank. The alternate site is located more than 10’ away. There is one test hole on the lot with a soils log, percolation testing, and groundwater monitoring. In addition, we are submitting additional test holes from neighboring lots and from the geotechnical report in the road. All demonstrate no impermeable layers down to more than 16’ and no groundwater developing at any point. We request that this additional test hole information be accepted to demonstrate adequate separation to groundwater and to impermeable layers. Please refer to the attached test hole logs, soils lab analysis, plan and profile pages for the septic design. If this design is followed, there will be no adverse impacts to adjacent properties. Sincerely, Benjamin Schiller, PE Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP221355, Deb Wockenfuss, 09/23/22 ALTERNATE SITE MIN 8' SEPARATION Benjamin Schiller CE 12592R EGISTEREDPROFES S I O N ALENGINEER 1"=50' 50' LONG x 5' WIDE, 4' EFFECTIVE DEPTH ABSORPTION TRENCH 1250-GAL SEPTIC TANK w/ 20" MANWAY CO - CLEANOUT 2CO - DOUBLE CLEANOUT FCO - FOUNDATION CLEANOUT FS - FLOW SPLITTER VALVE MH - MANHOLE MT - MONITORING TUBE SV - SEPTIC VENT TH - TEST HOLE LEGEND TH#4A MOSSFLOWER WOODS, LOT 4 FEET 0 50 100 FCO NOTE: NO SLOPES >25% WITHIN 50' OR SURFACE WATER WITHIN 100' OF THE PROPOSED SEPTIC SYSTEM ALL WELLS ON SURROUNDING LOTS WITH IMPACTS TO THIS PROPERTY ARE SHOWN. NO CONFLICTS WITH WELLS OR SEPTIC SYSTEMS.FIRESIDE CIRCLE4-BDRM HOME10' T&E EASEMENT E. 112th AVENUE 400 405 410 415 420 2CO CO CO PROPOSED WELL WITH 100' RADIUS MT MT WELL RADII FROM LOTS 2&3 WELLS ARE OFF PAGE. SEE NOTE AT BOTTOM OF THIS SHEET NEIGHBORING LOT WELL RADII NEIGHBORING SEPTIC SYSTEM 9/20/22 ≥10' Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP221355, Deb Wockenfuss, 09/23/22 MOSSFLOWER WOODS, LOT 4 TYPICAL TRENCH SECTION (NO SCALE) NOTES: 1. GRADE AREA OVER TRENCH TO DRAIN AWAY 2. PROVIDE 3' OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2' WITH 2" OF INSULATION 3. CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY Benjamin Schiller CE 12592R EGISTEREDPROFES S I O N ALENGINEERSep 06, 2022 4" PERFORATED PVC (HOLES DOWN) DRAINFIELD ROCK 5' 6" 3' 4' DESIGN FACTORS:SYSTEM REQUIREMENTS: 600 GPD PEAK FLOW PERK RATE: <1 MIN/IN APPLICATION RATE: 1.2 GPD/SF 5' WIDE TRENCH SYSTEM 1,250-GAL SEPTIC TANK BOTTOM OF TRENCH: 7' BELOW GRADE FLOW LINE ELEVATION: 3' BELOW GRADE TOP OF TRENCH: 0.5' ABOVE GRADE 600 GPD / 1.2 GPD/SF / 5-WIDE * 0.5 RED (4' DEEP) = 50 LF TRENCH REQUIRED (50 LF SPECIFIED) GEOTEXTILE FABRIC Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP221355, Deb Wockenfuss, 09/23/22 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Section 4U*j700 Elmore St. P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907)343-7904 Soils Log - Percolation Test Performed For: LAND LCC Legal Description: MOSSFLOWER WOODS, LOT 4 1- 2- 3- 4- 5- 6- 7- 8- 9- 10- 11- 12- 13- 14- 15- 16- 17- 18- 19- 20 - �u .E 09ap'N"C5 (0� S11.N SAO (5M) &AVIF, w1 5A�D 5 Stli CSP- C-tM� C'IkP*L Ftp ;D 3" 50µi CoB>;+O Date Performed: Township, Range, Section: WAS GROUND WATER ENCOUNTERED? NO s 30vk IF YES, AT WHAT DEPTH? L Depth to Water After P Monitoring? NGWE E Date: 10-19-20 I I 1 /0/10 /2-0 AJ,,i, OF A4 -\A4 Z. v NTYl'. ' THEWS • CE 135444 FE 10 10-17-20 Site Plan SEE ATTACHED SITE PLAN Reading Date Gross Time Net Time Depth to Water Net Drop 10-17-20 --- 0 MIN 50" --- 5 MIN 5 MIN 52.25" 2.25" 5 MIN 10 MIN 56.5" 6,5° 5 MIN 15 MIN 59.5" 9.5" PERCOLATION RATE 2 (minutestinch) PERC HOLE DIAMETER 6" TEST RUN BETWEEN 4 FT AND 5 FT COMMENTS HOLE WAS PRESOAKED PRIO TO TESTING. PERC READINGS ARE WITHIN 1/4" PERFORMED BY: TRIAD ENGINEERING, LLC I GRANT MATHEWS, PE CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: 10-19-20 Depth (Feet) 1- 2- 3- 4- 5- 6- 7- 8- 9- 10- 11- 12- 13- 14- 19- 20- FT AND FT I (ENGINEER'S SEAL) Performed For: Legal Description: 15- 16- PERC HOLE DIAMETER Date Gross Time Slope Site Plan PERCOLATION RATE (minutes/inch) Net Time Depth to Water Net DropReading COMMENTS TEST RUN BETWEEN 17- 18- PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: CERTIFY THAT THIS TEST WASPERFORMED BY: (907)343-7904 Soils Log - Percolation Test Township, Range, Section: WAS GROUND WATER ENCOUNTERED? IF YES, AT WHAT DEPTH? S L O P E Date: Depth to Water After Monitoring? Date Performed: Municipality of Anchorage Development Services Department On-Site Water and Wastewater Section 4700 Elmore St. P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite 8-14-22 Mossflower Woods, Lot 4 Patrick Noblett See attached site plan No NGWE 8-30-22 6.000" 0.000" 6.000"2 min 6.000" 2 min 4 min 0.000" 2 min 6.000" 6.000" 2 min 6 min 0.000" 6.000" Added 2 gallons of water in less than 1 minute. All water absorbed in less than 2 minutes. Repeated test multiple times with same results. Material is predominantly sand (visual classification). A sand liner should not be required. Triad Engineering, LLC Grant Mathews 14:11 14:13 14:15 14:17 1 2 3 ---- ---- ---- ---- -------- ---- ---- ---- 6" 4.5 5.5 <1 8-30-22 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP221355, Deb Wockenfuss, 09/23/22 % GRAVEL 27.8 USCS SW-SM % SAND 65.4 USACOE FC N/A % SILT/CLAY 6.8 % PASS. 0.02 mm N/A % MOIST. CONTENT 6.2 % PASS. 0.002 mm N/A N/A N/A N/A SIEVE SIEVE TOTAL %SPECIFICATION SIZE (mm)SIZE (U.S.)PASSING (% PASSING) 152.40 6" 76.20 3"100 38.10 1.5"95 19.00 3/4"83 12.70 1/2"79 9.50 3/8"76 4.75 #4 72 2.00 #10 67 0.85 #20 55 0.43 #40 29 0.25 #60 16 0.15 #100 10 0.075 #200 6.8 ELAPSED DIAMETER TIME (MIN) (mm) 0 1 2 5 8 15 30 60 250 1440 SOUNDNESS OF AGG. (ASTM C88) DEGRADATION (ATM T-313) LA ABRASION (ASTM C131/C535) SP. GRAV. COARSE AGG. (ASTM C127) 11301 Olive Lane ∙ Anchorage, Alaska 99515 ∙ Phone: 907-344-5934 ∙ Fax: 907-344-5993 ∙ www.nge-tft.com N/A N/A The testing services reported herein have been performed to recognized industry standards, unless otherwise noted. No other warranty is made. Should engineering interpretation or opinion be required, NGE-TFT will provide upon written request. N/A HYDROMETER RESULT N/A SIEVE ANALYSIS RESULT 2022 Materials Testing 6309-22 Mossflower Woods Lot 4 22-S-6 Well-graded sand w/ silt and gravel 8/26/2022 Erik Boatwright Andrew Fortt TOTAL % PASSING 9.1 1.0 Forge Engineering, Inc.PROJECT CLIENT: PROJECT NAME: PROJECT NO.: SAMPLE DESC.: NGE-TFT ID #: CLASSIFICATION: DATE RECEIVED: TESTED BY: REVIEWED BY: UNIFORMITY COEFFICIENT (Cu) COEFFICIENT OF GRADATION (Cc) ASTM D1557 (uncorrected) ASTM D4718 (corrected) OPTIMUM MOIST. CONTENT. (corrected) 115 120 125 130 135 140 145 0 2 4 6 8 10 12 14 16DRY DENSITY (pcf)MOISTURE CONTENT (%) MOISTURE-DENSITY RELATIONSHIP ASTM D1557 SILT or CLAYCOBBLES GRAVEL Coarse Fine SAND Coarse Medium Fine 0 10 20 30 40 50 60 70 80 90 100 0.0010.010.1110100FINER BY MASS (%)GRAIN SIZE (mm) PARTICLE SIZE ANALYSIS ASTM D6913 / C136 / D422 #200#40#101.5 1/2363/4 #4 #20 #60 #1003/8 U.S.SIEVE OPENING IN INCHES U.S.SIEVE NUMBERS HYDROMETER