HomeMy WebLinkAboutCANYON VIEW ESTATES BLK 2 LT 2 Canyon View Estates Block 2 Lot 2 #021-021-48 trcev uomwitsy Municipality of Anchorage On -Site Water and Wastewater Section • (907) 343-7904 Page 1 of 2 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP221432 PID Number: 021-021-48 Dwelling: ❑■ Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: ❑■ New ❑ Upgrade Name HULTQUIST HOMES ABSORPTION FIELD El Deep Trench 0Wide Trench ❑ Bed El Mound Ad Address ddress 13764 CANYON ROAD ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 4 1.0 GPD/SF 1.0 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade 0.5 Ft. Gravel depth beneath pipe 0.5 Ft. Subdivision Block Lot CANYON VIEW ESTATES 2 2 Fill added above original grade 3.0 Ft. Gravel length 2 @ 60LF Ft. Township Range Section Gravel width 5.0 Ft. Beds: Number of Lines NA Distance between lines NA Ft. SEPARATION DISTANCES To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Tank Line 600 Ft2 2 8.1 Ft. Well 100'+ 100'+ NA NA 25'+ TANK ❑ri Septic ❑ S.T.E.P. ❑ Holding ❑ Other Manufacturer GREER Capacity 1250 Gal. Surface Water 100'+ 100'+ NA NA Material Number of compartments Lot Line 51+ 10'+ NA NA NA HDPE 2 Foundation 10'+ 10'+ NA NA LIFT STATION Manufacturer Capacity Remarks Gal. Alarm location Electrical installed by Installer PIPE MATERIAL House to tank 3034 Tank to drainfield 3034 Bronwson Bros, LLC. Drainfield 3034 CO/MT3034 Inspector PES BENCH MARK (Assumed elevation) 1148.5 ft Inspdection 15` 11/22/22 11/23/22 Location and description 3rd 11/24/22 2nd 4'" 11/25/22 See Site Plan, South West corner House trim ON-SITE WATER AND WASTEWATER SECTION APPROVAL Engineer's Stamp '�''• Conditional Approval: Date AG ... ....... "$even an CE 8149 Septic Syste Approved Date �4pIOF>E�tltW' N this approval does not include well permit require en trcev uomwitsy PR O F I L E PANNONE ENG SVC, LLC (C.I. 1088) SC A L E : 1" = 5 0 ' MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 hftp://www.muni.org/onsite On -Site Water & Wastewater System Permit Permit Number: OSP221432 Work Type: WellSeptic Initial Tax Code Number: 02102148000 Site Legal Address: CANYON VIEW ESTATES BLK 2 LT 2 G:3042 Site Mailing Address: 13764 CANYON RD, Anchorage Owner: HULTQUIST HOMES INC Design Engineer: PANNONE ENGINEERING SERVICES This permit is for the construction of: Q Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy Effective Date: Expiration Date: Lot Size in Sq Ft: Total Bedrooms: �11enr o IS, ti f llcpaI- tillellt 11/21/2022 11/21/2023 65459 Q Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Received By: (S � � 1'A /.,v0/' . Date: Issued By: Date Zt Z Z 4 ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 021-021-48 Property owner(s) HUltquiSt Homes Day phone Mailing address Site address NHN Canyon Road Legal description (Sub'd., Block & Lot) Canyc Legal description (Township, Range & Section) Lot Size 65,459 Sq. Ft. Number of Bedrooms n View Block 2, Lot 2 APPLICATION IS FOR: (® all that apply) Upgrade Absorption Field ❑X Septic Tank ❑X Holding Tank ❑ Privy ❑ Private Well X❑ Water Storage ❑ APPLICATION IS AN: Initial K Upgrade ❑ Renewal ❑ 0 TYPE OF DWELLING: Single Family (SF) ❑X (w/wo ADU) Duplex (D) ❑ Multiple Dwellings ❑ (SF and/or D) THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: 3 aiU Waiver Fees: _ Date of Payment: lo�l��a,a Date of Payment: Receipt Number: Receipt Number: Permit No. (3 Waiver No. Permit App_:- : . _..:c 04/16/2023 01:10 907-345-0202 ALPINE DRILLING PAGE 01/01 Alpine Drilling & Enterprises Well Log Permit Number: #SW221432 Date of Issue: 11-21-2 Parcel Identification Number: 02102148000 Date Started: 11-11-22 Date Completed: 11-12-22 Is well located at approved permit location? x Yes [] No Legal Description: Canyon View Estates Block 2 Lot 2 Property Owner Name & Address: Hultquist Homes, Inc Borehole Data: Depth (ft) Soil 'Type, Thickness & Water Strata From To stick-up 0 2 Organics & silt 2 3 silty cobbly gravel 3 27 silt 27 36 silty sandy gravel H2O 5gpm 36 42 gravelly silt 42 97 silt 97 104 gravelly silt 104 127 bedrock 127 206 X01 113-19q+ Method of Drilling x air rotary ❑ cable tool Caning type: steel Wall Thickness:.250 inches Diameter: d inches Depth: 129 feet Liner Type: Diameter: inches Depth: _ _ feet Casing stickup above ground: 2 feet Static water level (from ground level):.103 eet Pumping level: 200 feet after 2 hours pumping 20 gpra Recovery Rate: 20 gpm Method of Testing: air Ii Well Intake Opening Type: [] Open End x Open Hole ❑ Screened Start _ feet Stopped feet ❑ Perforations Start feet Stopped feet �IGrout Type: bentonite granules Volume: 1 I Dench: Start 0 feet Stooped ? feet -- Pump: Intake Depth feet Pump size hp Brand Name Well Disinfected Upon Completion? x Yes ❑ No Method of Disinfection: chlorine tablets Comments: Well Driller: Alpine Drilling & Enterprises PO Box 110496 Anchorage AK 99511 MUNICIPALITY.:,O,F ANCHORAGE �a m VEL SERVICESDEPARTMENT�... �� •_•' k On-SiteWater and WastewaterSectionFax.- 343-7997 y, www.muni.org/onsite: PERMIT # OSP221432 PID023 -021-48 sugoCanyort View TRACT BLOCK 2 LOT 2 APPROVED (date) E HOURLY RATE $145 Pannone Engineering Services LLC Steven R. Pannone, Principal Registered Professional Engineer E-mail: steve@panengak.com Mailing: P.O. Box 1807, Palmer, AK 99645 Telephone: (907) 745-8200 FAX: (907) 745-8201 27 June 2023 Municipality of Anchorage Development Services Department On-Site Water & Wastewater Program 4700 Elmore Road P O Box 196650 Anchorage, Alaska 99519-6650 Subject: Canyon View Estates Block 2 Lot 2 Septic Tank & Deck Ladies and Gentlemen: This is a documentation letter of the existing 1250gal septic tank installed the subject property on (05/04/2022). This septic tank has a total depth of 6.83' from original grade & 8.83' from finish grade. This septic tank is located approximately two-point-seven (2.7’) feet from an existing deck. The existing deck is installed on a pile foundation that extends a minimum of (16’-4’’) below finish grade and will not affect the structural integrity of the existing septic tank. If you have any questions or concerns, please contact me at 907.745.8200. Sincerely, J.R. Lawendowski, P.E. Civil Engineer Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP221432, Curtis Townsend, 11/21/22 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP221432, Curtis Townsend, 11/21/22 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP221432, Curtis Townsend, 11/21/22 O_ _, Z 'O O (°) J O U L + 3 o a) O E O o O p E U v Q'' C 7 ++ N 1 '0 U C O C Q) _j o o a� v o > 0 0 V) ¢ L� cn CL O U d- N U O O O N O) O � U-) I c o II o U O -v N o C O " c '0.- hi o� C7i v C U O> U) d CL E 0 0 �� 2 0 n. ^ O Y o :p -p s.. U m N _- o (D v� p 0 U 0 CC3 N > ° o Ov cc�0 (� O >,z W Cid U" o o • Y N L N L 2 C O YS ._ N0 t w '—' 0 �c0 a0 s (v U 0) E v �'v i� — ag° o O ' 0 .n c o i ✓ L() 0 a) (n C .O Q) U0) �: af N dU (n O L Q 1 N O O C O N N O U O" O O Ua Q) a + c p ��> V a>i06oc'oE > N (p 'v a) 3 a' J �v0X�'' 00 U)SZ a)a:!1 rna) ° O 0 o Ll Steven K.Pannone, Principal Registered Professional Engineer E-mail: steve@panengak.com 2June 2O33 Municipality ofAnchorage Development Services Department On -Site Water & Wastewater Program 47U0Elmore Road POBox 196G5U Anchorage, Alaska 99519'665O Subject: Canyon View Estates Block 2Lot 2 Septic Tank toDeck Waiver Ladies and Gentlemen: We request a separation distance waiver for an existing septic tank to deck support of (1.4'). This is an existing septic tank that was installed on 2.The tank has been inoperation since installation. Granting this waiver is not likely to affect the health and safety of this lot or the surrounding lots now or in the future. If you have any questions or concerns, please contact me at 907.745.8200. Sincerely, Steven R.Pannone, P.E,F.ASCE Owner/Civil Engineer K/1,ai|in�P. BoxI8O7,Po|rnei -AK99G45 Te1ephOne:1907\745'82QO FAX: /9O7\745'82OI M UHUP L UTY OF HCHO AGE Development Services Department Phone: 907-343-7904 On -Site Water & Wastewater Section Fax. 907-343-7997 Certificate of On -Site Systems Approval Parcel I.D. 021-021-48-000 Expiration Date: Legal description CANYON VIEW ESTATES BLK 2 LT 2 Site address 13764 CANYON RD Anchorage AK 99516 Current property owner(s) BOLLONE ANN M X The On-site system(s) is/are approved for 4 bedrooms Conditional approval for Comments or advisories: 11/8/2023 bedrooms, with the following stipulations: Original Certificate Date: 8/8/2023 This Certificate of On -Site Systems Approval (COSA) is intended to demonstrate the subject system(s) is/are in substantial compliance with municipal code. The Municipality of Anchorage, Development Services Department (DSD) issues COSAs based upon representations provided by an independent professional engineer. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. ATTACHMENTS: COSA Checklist X Well Flow Advisory Absorption Field Advisory Nitrate Advisory Tank Age Advisory Arsenic Advisory Other COSA Approval June 2022 UX�C�P „ L �� �� 0 F ' (o FRA GE s�-. d'ifi Development Services Department Phone. 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Certificate of On -Site Systems Approval Application 1. GENERAL INFORMATION Parcel I.D. 021-021-48 Complete legal description Canyon View Estates Block 2 Lot 2 Location (site address) 13764 Canyon Road Current property owner(s) Hultquist Homes Inc. Day phone 2. ON-SITE SYSTEMS SIZED FOR 4, BEDROOMS 3. TYPE OF WATER SUPPLY: Q Private Well ❑ Private Well serving 2 dwelling units ❑ Private Well serving 3+ dwelling units ❑ Community Well or Public ❑ Water Storage 4. TYPE OF WASTEWATER DISPOSAL: ®❑ Private Septic ❑ Private Septic serving 2 dwelling units ❑ Holding Tank ❑ Community Septic or Public Sewer 5. SEPTIC TANK: ❑ Steel ❑ Plastic ❑ Concrete ❑ Fiberglass Age <1 - See advisory if steel older than 20 years 6. ABSORPTION FIELD: ❑ AWWTS ❑ Bed ❑ Deep Trench ❑® Wide Trench ❑ Seepage Pit Waiver request for: Tank to deck distance Distance: 1.4' Expedited review requested: ❑ By applying for this entitlement, this property_ is_subject _to_inspection-by municipal On-site staff to verify the accuracy of the information provided. COSA Fee $ 7 Date of Payment 4' 2o, Z- 3 COSA # Waiver Fee $ / y_5 - Date of Payment Waiver# COSA Applicationjune 2022 COSA Checklist_June 2022 COSA Checklist Legal Description: Parcel ID: If more than 1 well and/or septic system on lot, provide separate checklist. Structure served by this system ____ A. WELL DATA Well log is filed with Onsite (or attached) Date drilled Total depth ft Cased to ft Sanitary seal is functioning correctly Wires are properly protected Casing height (above ground) in. Date of flow test for COSA Static water level at beginning of test ft. Well production at time of test gpm Water storage tank volume gallons Well disinfected for coliform test? Yes No Coliform bacteria is Negative Nitrate mg/L Nitrate less than MRL (ND) Arsenic ug/L Arsenic less than MRL (ND) Collected by Date Comments __________________________________________________________________________________ B. TANK DATA Measured operating fluid level in septic tank Date of pumping Required maintenance completed, if AWWTS Comments: C. LIFT STATION Required maintenance completed Age of lift station years Lift station material Comments: D. ABSORPTION FIELD DATA Which system tested (date installed) ALL standpipes present per record drawing Total measured depth from grade ft (max) Measured depth to pipe invert from grade ft (min) N/A – pressurized field. Per record drawings, field is insulated. Monitor tubes go to bottom of effective. If not, state depth into effective Presoaked required if (Required if house vacant or field not used for more than 30 days prior to date of test) Gallons introduced gallons date Any rejuvenation treatment (past 12 months) If yes, enter date Adequacy test date Results Pass Fluid depth prior to test in Water added gal New fluid depth in Elapsed time min Final fluid depth in Absorption rate gpd FIELD STATUS – POST RECOVERY Effective depth (per record drawings) in Effective depth used in Effective depth remaining in Comments/Deficiencies: COSA Checklist_June 2022 E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well on lot) Septic Tank/Lift Station on Lot > 100’ Yes if No ft Neighboring Tank > 100’ Yes if No ft Absorption Field on Lot > 100’ Yes if No ft Neighboring Absorption Fields > 100’ Yes if No ft Community Sewer Main > 75’ Yes if No ft Community Sewer Manhole/Cleanout > 100’ Yes if No ft Private Sewer/Septic Line > 25’ Yes if No ft Holding Tank > 100’ Yes if No ft Animal Containment > 50’ Yes if No ft Manure/Animal Excreta Storage > 100’ Yes if No ft N/A – Served by Community Well (not on lot) or Public Water From Septic/Holding Tank and Absorption Field(s) on Lot to: (Please enter distances if less than required) Building Foundations > 10’ Yes if No ft Tank to Property Line > 5’ Yes if No ft Field to Property Line > 10’ Yes if No ft Water Main > 10’ Yes if No ft Water Service Line > 10’ Yes if No ft Surface Water > 100’ Yes if No ft Wells on Adjacent Lots: Private Wells > 100’ Yes if No ft Community Wells > 200’ Yes if No ft If tank or field is under driveway comment below F.ENGINEER’S COMMENTS G.CERTIFICATION & STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines, indicates that the on-site water supply and/or wastewater disposal system appears to comply with applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation, unless noted otherwise. Name of Firm Phone Engineer’s Printed Name Date SUBSURFACE CONSTRUCTION LLC Wasilla,, AK 99654 June 20, 2023 Three 2-7/8"' steel pipe piling & one 3-1/2"s I pipe piling were installed at the direction of Garry With Hultquist Homes. Pipe was # 60 extra strong API 5LX-80 All welding was done using EX -70 Electrodes All welding was done by a certified 6g pipe welder Drive hammer was a Bobcat HB980 Pile was driven to FULL STOP REFUSAL Pile was driven to a terminal driving rate of 1 inch in 60 seconds I - CDC Pg depth in the front is 16'-4" * Piling depth in a is from left to right: 17"-10", 19`-8`#jV & 20,P -111Y bevelopment Services bepcar tment il ding Safety Division 9M On -Site Water & Wastewater Program 4700 Elmore Road P.O. Box 196650 Mark Begich Anchorage, AK 99507 Mayor www.muni.org/onsite (907) 343-7904 Pump Installation Log Well Drilling Permit Number: Date of Issue: Parcel Identification Number: Legal Description Property Owner Name & Address: cc,-V�Von Cent O&V\ 1z L_ Ro n -e Pump Installation Date: 5 — A 1 _ 2__� Pump Intake Depth Below Top of Well Casing: I q I feet Pump Manufacturer's Name: (�VVAJ�0) Pump Model: I b 5 q P, 0 7 - � e-1 0 Pump Size 3�q hp Pitless Adapter Burial Depth: ) I I 1� feet Pitless Adapter Manufacturer's Name: Ca -Vi Pitless Adapter Installer: �LtiatA,,-t Well Disinfected Upon Completion? Yes n No Method of Disinfection: C,A I kr- to Comments: Pump Installer Name: Johnny Kay Hefty Ddiling, Inc. Attention: The pump installer shall provide a pump installation log to the DSD within 30 days of pump installation.