HomeMy WebLinkAboutFRISLIE LT 5Onsite File
I :>
Municipality of Anchorage o °�
On -Site Water & Wastewater Program
(907) 343-7904
CERTIFICATE OF ON—SITE SYSTEMS APPROVAL
Parcel I.D. 014-162-36 Expiration Date:
1. GENERAL INFORMATION
Complete legal description FRISLIE. LOT 5
Location (site address) 7821 LADASA PLACE *ANCHORAGE AK
Current Property owner(s) LEVI SMITH W/ GLACIER HOMES Day phone 748-4197
Mailing address
Real Estate Agent
2. TYPE OF DWELLING:
7821 LADASA PLACE *ANCHORAGE AK
Single Family (w/wo ADU)
❑ Duplex
❑ Multiple Dwellings (Single Family and/or Duplex)
3. NUMBER OF BEDROOMS: 4
4. TYPE OF WATER SUPPLY:
Day phone
TYPE OF WASTEWATER DISPOSAL:
Individual Well
0
Individual On-site
❑
Individual Water Storage
❑
Individual Holding tank
❑
Community Class Well
❑
Community On-site
❑
Public Water System
❑
Public Sewer
Received by: '4:1/Date:
COSA to be released to the engineer, unless otherwise requested by the engineer. `
COSA Fee $ �"s� Waiver Fee $
Date of Payment �J �1 i �J _ Date of Payment
Receipt Number O J`J % Receipt Number
COSA # 05C. 13110 to Waiver #
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seat affixed hereto and as of the validation date shown below, I verify that my
investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the
information obtained from the Municipality of Anchorage files and from my investigation and inspection, the
on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal
and State codes, ordinances, and regulations in effect at the time of installation.
Name of Firm GARNESS ENGINEERING GROUP, Ltd.
Address 3701 E. TUDOR ROAD, SUITE 101 * ANCHORAGE, AK 99507
Engineer's Printed Name JEFFREY A. GARNESS, P.E.
Engineer's Comments:
.In conducting this evaluation, GEG, UD. attempted to provide a thorough,
conscientious engineering analysis of the system in accordance with ADEC and MOA
DSD Guidelines & Regulations. The reported results described the performance of the
system under the conditions encountered at the time of the test, and separation
distances measured to readily identifiable features. The operational life of all wells and
septic systems depend on the local soils condition, groundwater levels that may
fluctuate during the year, and the water usage of the family being served by the system.
These conditions are outside the control of the evaluator of the system. Satisfactory test
results do not guarantee future performance of the system, nor do they guarantee that
there are no hidden defects or encroachments. GEG, LTD. can therefore not provide
any warranty or future estimate of how long the system will continue to meet the
operational requirements of the ADEC or MOA DSD. The content of this report is for
the sole benefit of the owner listed above. Any reliance upon or use of this report by any
other person or party is not authorized, nor will it confer any legal right whatsoever.
6. DSD SIGNATURE
t -System #1 Approved for bedrooms.
System #2 Approved for
Disapproved.
Conditional approval for
bedrooms.
Phone 337-6179
Date 3 Ag 1 1-7 _
�F
.. 49 . ..................
�y Ga Hess;
9; CE
144p ^e. �
0�-"4'rofessio_
bedrooms, with the following stipulations:
Original Certificate Date:
�(tOF IV6r6;;,
�UeP yO�pr�r-
J� ON-SITE 0
v WATER ANL'
�o WASTEWATER ,^
PROGRAM
CAT
The Wni6fipaliVorAifhorage Develop,emt Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only
upon the represenatations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska.
The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work.
7. ATTCHMENTS: /
COSA Checklist / Nitrate Advisory
Septic System Advisory
Well Flow Advisory
(Rev. 11105)
Arsenic Advisory
Other
If more than 1 septic system is on the lot:
COSA Checklist # of
Structure served by this system
Legal Description: FRISLIE, LOT 5 Parcel ID: 014-162-36
A. WELL DATA
Well type PRIVATE if A, B, or C provide PWSID# N/A Well Log (YIN) YES
Date. completed 7/25/12 Sanitary seal (YIN)1'cS t Wires properly protected (YIN) _
Total depth 82 ft. Cased to 82 ft. Casing hei ht (above round 24+
FROM WELL LOG
Date of test 7/25/12
Static water level 21 ft.
Well production 20 _g—
p.m-WATER SAMPLE RESULTS:.
9 9 ) H.
AT INSPECTION
NEW WELL
ft.
9-13-m.
Coliform colonies/100 ml. Nitrate 1`1 D mg./L. Collected by: GEG. Ltd.
Arsenic: ND ug./L. Date of sample: 3/191 3 [2o /a
B. SEPTIC/HOLDING TANK DATA PUBLIC SEWER
Tank Type/Material Date installed
Tank size gal. Number of Compartments Cleanouts (YIN)
Foundation cleanout (YIN) Depression over tank (YIN) High water alarm
Date of pumping Pumper
C. ABSORPTION FIELD DATA
Date installed Soil rating (g.p.d./ftZor Obd
Length ft. Width
System type
ft. Gravel below pipe ft,
Total depth ft. Eff. absorption ftZ Monitoring tube Depression over field
Date of adequacy test Results (Pass/Fail) For bedrooms
Fluid depth in absorpf Ield before test in. Water added gal. New depth in.
Elapsed Ti min. Final fluid depth in. Absorption rate >= g.p.d.
A ejuvenation treatment (past 12 mo.) (YIN & type) If yes, give date
D. LIFT STATION
Date installed
"Pump on" level at in.
Size in gallons Manhole/Access (YIN).
"Pump off level High water alarm level at in.
Cycles tested Meets alarm & circuit requirements?
E. SEPARATION DISTANCES
SEPARATION DISTANCES FROM WELL ON LOT TO:
Septic tank/lift station on lot - N/A
Absorption field on lot- N/A
On adjacent lots_ N/A
On adjacent lots N/A
Public sewer main 75+ Public sewer manhole/cleanout 100'+
Sewer/septic service line 25'+ Holding tank N/A
Animal containment areas 50'+ Manure/animal excrete storage areas 100'+
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO:
Building foundation
Water main
Wells on adjacent lots
Property line Absorption fiek
Water service line Surface water,
SEPARATION DISTANCE FROM ABSORPTION FI
Property line _
Water service line
F. COMMENTS
Surface water
Wells on adjacent lots
TO:
Water main
Driveway, parking/vehicle storage
G. ENGINEER'S CERTIFICATION
I certify that I have determined through field inspections and
review of Municipal records that the above systems are in
conformance with MOA COSA guidelines in effect on this
date.
Engineer's Printed Name JEFFREY A. GARNESS _
Date 3 I� /3
(Rev. 11/05)
OF
o *.: 4 . T ..............
........
CE— ••�
L�R'f'o f es Sion°d
4
re)
30VId VSVCIV-1
r
U
w
Aw
N N
00
w
.�
�
C)
a
� �
o
49,
0
criz
0
z
Is
a
LLJLLa
4
re)
30VId VSVCIV-1
W0ZC)
F-E-Wza.a"'- w
zo c!w W C) w
t -z0
v�Q M0D F
L
20 ar = 0
_It'�W0� CC 0
w�0�-nary p
v� �Lu
w < Q=z = Lu
ar CL m cr a -' v t -
WOO ' CLaw LU:
wi r,,
Cn O
v -s � M
w to
p ..5 U) 04
z
O
2r
�tLu
tr 0 g z a
v� LJ = CL
�; v Cd
o
Aw
00
qLL
-o N ° o
O Q t °
O Zi f
•��" q
C °
49,
Is
W0ZC)
F-E-Wza.a"'- w
zo c!w W C) w
t -z0
v�Q M0D F
L
20 ar = 0
_It'�W0� CC 0
w�0�-nary p
v� �Lu
w < Q=z = Lu
ar CL m cr a -' v t -
WOO ' CLaw LU:
wi r,,
Cn O
v -s � M
w to
p ..5 U) 04
z
O
2r
�tLu
tr 0 g z a
v� LJ = CL
�; v Cd
o
Alpine Drilling & Enterprises
Well Lag
Permit Number: #SW12� 1 Date of Issue: 712
Date Started: 7-25-12 Date Completed: 7-25_1? parcel Identification Number: 01416236000
Legal Description; Frlslie Lot 5 Is well located at approved permit location?
Property Owner Name & Address: Levi & Neid' S x Yes ❑ No
Pump: Intake Depth feet -�
Pump size hp Brand Name _
Well Disinfected Upon Completion? x Yes [I No
Method of Disinfection: chlorine tablets
Comment,:
V Welt Driller: Alpine Drilling & Enterps ises
PO Box 110496
Anchorage AK 99511
� mtth
5701 Whispering Spruce Drive
Borehole Data:
Anchorage, Alaska 99507
Soil Type, Thickness & Water StrataDepth
(ft)
From To
Method of Drilling x air rota ry ❑ cable too]
Stick-up
Casing type: steel
Organics & silt
0 2
Wall Thickness:.2So inches
Gravelly silt
2 3
3
Diameter; 6 inches Depth: 82 feet
Liner Type:
silty grave,
5
5 54
Diameter: inches Depth: feet
silt
54
Casing stickup above ground: _2 feet
silty gravel
61
61
Static water level (from ground level); 21 feet
silty nater sand & gravel79
79
82
Pumping level: 80 feet after
2 hours pumping 20
gpm
Recovery ,Rate: 20 gpm
Method of Testing: air Ii
Well Intake Opening Type:
x Open End . _. 0 Open Hole
❑ Screened Start feet Sto
Stopped_ feet
❑ Perforations
St
Start feet Stopped feet
Grout Type: ben- ntorit?
Depth: Volume: I bg
Pump: Intake Depth feet -�
Pump size hp Brand Name _
Well Disinfected Upon Completion? x Yes [I No
Method of Disinfection: chlorine tablets
Comment,:
V Welt Driller: Alpine Drilling & Enterps ises
PO Box 110496
Anchorage AK 99511