Loading...
HomeMy WebLinkAboutRABBIT CREEK VIEW & HEIGHTS BLK 4H LT 8A Rabbit Creek View & Heights Block 4H Lot 8A #020-551-22 Municipality of Anchorage On -Site Water and Wastewater Section • (907) 343-7904 Page 1 of 2 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP221416 PID Number: 020-551-22 Dwelling: ❑■ Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: ❑■ New ❑ Upgrade Name ILNITSKIY ABSORPTION FIELD ❑ Deep Trench ❑ Wide Trench ❑ Bed X Mound Site Address 7903 VIOLA CIR, ❑ Other Phone Number of Bedrooms Soil Rating — Total depth from original grade 7 4 2.3 GPD/SF +1.5 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade +2,0 Ft. Gravel depth beneath pipe 0.5 Ft. Subdivision Block Lot RABBIT CREEK VIEW & HEIGHTS BLK 4H LT8A Fill added above original grade 5.5 Ft. Gravel length 51 Ft. Township Range Section Gravel width 5.0 Ft. Beds: Number of Lines pistance between lines Ft. SEPARATION DISTANCES To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Tank Line 255 Ft 2 1 Ft. Well 501+ 501+ 501+ TANK ❑ Septic ❑ S.T.E.P. ❑ Holding X Other Manufacturer Capacity ANCH TANK/ADVANTEX 1500 Gal. Surface Water 50'+ 50'+ Material Number of compartments Lot Line 10'+ 10'+ NA FIBERGLASS 2 Foundation rJ01+ 1 0'+ LIFT STATION Manufacturer Capacity G� "C'k Gal. ,/ � Remarks �nr%lla ✓� /nn� /,,�a5 ilofl�terl Y /rluahX r1-ud Alarm location Electrical installed by ���-C—T. PIPE MATERIAL House to tank 3034Tank to 3034 drainfield Installer MIKE N ANDERSON, P.E. Drainfield 3034 co/MT3034 Inspector MIKE N ANDERSON, P.E. BENCH MARK (Assumed elevation) 105.5 ft Ins daction 1-1 2/25/23 2/26/23 Location and description tes: 2"d OF ADVANTEX MANHOLE 3'd 4'" ITOP ON-SITE WATER AND WASTEWATER SECTION APPROVAL �•'Q*.6ea8,tamp Conditional Approval: Date ":•' • 'A� r ..... ......• p r f •.ee.♦ . ... e........ Septic Syste lith ;`, ; : c 9 c9 c 3 y .QV Approved Date y/J 7 i . •'� 1::.4' Note: this appro does not include well permit requirements. iKev u5iuznr5) W April 5, 2023 Municipalities of Anchorage Development Services Dept. On-Site Water & Wastewater Section Anchorage, Alaska 99519 Phone 343-7904 Re: Septic Field Revision Legal: RABBIT CREEK VIEW & HEIGHTS BLK 4H LT 8A To Whom it may concern: This is my letter is to explain how the system is rated for a 4-bedroom system. The Advantex tank is 1500 gallon therefore it’s the correct size. The field is 51 feet long x 5 feet wide x 0.5 foot deep so the total area is 255 square feet. So, the application rate is 600 GPD/SF / 255 SF equals 2.35 GPD. The perc was 22 minutes so the application rate is within the MOA acceptable rates for a 4-bedroom system. This change order will not impact any of the surrounding neighbors. Sincerely Michael N. Anderson, P.E. 4661 Natrona Anch, Ak 99516 Ph 727-8864 �Moll ITWVMF�_ Development Services Department Phone: 907-343-7904 On -Site Water & Wastewater Section 0 Fax: 907-343-7997 Well Log Permit Number: # osp221416 Date of Issue: 1120123 Parcel Identification Number: 020-551-22 Date Started: 1/25123 Date Completed: 1127/23 Is well located at approved permit location? Yes ❑■ No ❑ Legal Description: Rabbit Crk View & Heights BLK 4H IT 8A G:3340 Property Owner Name & Address: Taras ILnitskiy 7903 Viola Cir. - Anchorage,AK Borehole Data: Depth (ft) Soil Type, Thickness & Water Strata From To Casing stick up 0 2 sand & gravel 2 4 peat 4 15 clay 15 18 sand & gravel 18 50 sand & gavel w/ silty H20_ _ 50 52 sand & gravel 52 58 boulder 58 60 sand & gravel 60 60 sand & gravel w/ little H2O 80 82 sand & gravel 82 97 silt & gravel w/ clay & Iitfie H2O tight silty sand & gravel 97 112 112 120 silty clay w/ wet lenses 120 190 wet silt & gravel 190 197 silty sand & coarse gravel w/H20 197 200 Water Sample Results: Arsenic: Nitrates: total Coliform Bacteria: ug/L mg/L colonies/100mL Method of Drilling 0 air rotary ❑ cable tool Casing type: steel Wall Thickness: -250 inches Diameter: 6 inches Depth: 200 feet Liner Type: Diameter: inches Depth: feet Casing stickup above ground: 2 feet Static water level (from ground level): 0 feet Pumping level: feet after hours pumping __gpm Recovery Rate: wpm Method of Testing: airlift E Open End ❑ Open Hole ❑ Screened Start feet Stopped _feet ❑ Perforations Start feet Stopped _feet 20' Start 0 20 Well Disinfected Upon Completion? Yes No Method of Disinfection: Tabs Comments: 11 Well Driller: Johnny Key El ❑ Company: Hefty Drilling, Inc. Mailing Address: po box 112130 Anch AK 99511 Attention: The well driller shall provide a well log to the On-site Water and Wastewater Section within 30 days of completion. e'trt'iDpment Services Departs }en" Building Safety bivisimst 4700 Eirriore Road Uz P.O Bax 196650 c SP ETY Mark Begich Anchorage, AK 99507 Mayor mm.muni.oro/onsite (907)343-7904 Pump Installation Log / Well Drilling Permit Number: ,SW_Q5_� A,�ILll 16 Date of Issue: TO ! a 3 Parrel Identifiration Number: a)o- `)5l' da Legal Description p v ;5k-\ N �f�`� S �6�V, L4 Le -06A Property Owner Name & Address: 14��5 �Cn%k5�r�1 Pump Installation Date: Pump Intake Depth Below Top of Well Casing: ISO feet Pump Manufacturer's Name;�OW 1 0LS Pump Model: ! Pump Size III hp Pitless Adapter Burial Depth: () feet Pitless Adapter Manufacturer's Name: C 0.f It PitiessAdapter Installer. AnAwte-N Well Disinfected Upon Completion? I Yes ❑ No Method of Disinfection: Comments: WEjt BkSk� ���1ti`Il� �or Qrr�Q�1(�h �lo�l% Pump Installer Name: Johnny Kay Hefty Drilling, Inc. Attention: The pump installer shall provide a pump installation log to the DSD within 30 days of pump installation. MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 hftp://www.muni.org/onsite On -Site Water & Wastewater System Permit Permit Number: OSP221416 Work Type: WellSeptic Initial Tax Code Number: 02055122000 Effective Date: Expiration Date: Site Legal Address: RABBIT CREEK VIEW & HEIGHTS BLK 4H LT8A G:3340 Site Mailing Address: 7903 VIOLA CIR, Anchorage Owner: ILNITSKIY TARAS Design Engineer: ANDERSON CONSTRUCTION & ENGINEERING This permit is for the construction of: Q Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy »Zcnt a 96A I I U � r Department 1/20/2023 1/20/2024 Lot Size in Sq Ft: 33876 Total Bedrooms: 3 Q Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Received By: O A'S Date: Issued By: AA, Date: /h U _ MUNICIPALITY OF ANCHORAGE Development Services Department r Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Parcel I.D. 020-551-22 Property owner(s) TARAS ILNITSKIY Day phone Mailing address 1120 HUFFMAN RD STE 2, ANCH AK Site address 7901 VIOLA CIR, ANCH AK Legal description (Sub'd., Block & Lot) RABBIT CREEK VIEW & HEIGHTS BLK 4H LT 8A Legal description (Township, Range & Section) Lot Size 33876 Sq. Ft. Number of Bedrooms -3 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (® all that apply) Absorption Field 7 Initial FxJ Single Family (SF) 0 (w/wo ADU) Septic Tank Q Upgrade ElDuplex (D) ElHolding Tank ❑ Renewal ❑ Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well F Water Storage ❑ THIS APPLICATION INCLUDES A WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: Date of Payment: Receipt Number: Permit No. O S p �%)' alc2 Waiver Fees: Date of Payment: Receipt Number: Waiver No. GADevelopment Services\Building Safety\On Site Water and Wastewater\Forms\Client FormsTermit Application.doc Dec, 28, 2022 Municipalities of Anchorage Development Services Dept. On-Site Water & Wastewater Section Anchorage, Alaska 99519 Phone 343-7904 Re: Septic & Well Permit Legal: RABBIT CREEK VIEW & HEIGHTS BLK 4H LT 8A To Whom it may concern: This is a request for a septic and well permit on the above referenced lot. Two test holes was excavated and found 3 feet of organics then silty gravel (GM) mixed with silty sands (ML) to the bottom of the hole at eight feet. Water was observed at 3 feet with no changes after the 7-day monitoring period. The perc rate was 22 minutes per inch. Due to the lot size and soils an Advantex system has been designed for the lot. The lot slopes at 10 to 15 percent towards the north. No open water or cut banks exist with 100 feet of the proposed site. This new well or septic system will not impact any of the surrounding neighbors. Sincerely Michael N. Anderson, P.E. 4661 Natrona Anch, Ak 99516 Ph 727-8864 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP221416, Curtis Townsend, 01/20/23 1"=50' PROPERTY LINE PROPOSED NEW HOUSE PROPOSED WELL 50' RADIUS WELL SCALE: DJRDRAWN: DATE: RABBIT CREEK VIEW & HEIGHTS BLK 4H, LT 8A Anchorage, Alaska TARAS ILNITSKIY 12/21/2022 DRIVEW A Y NEW ROUND 1500 GALLON FIBERGLASS ADVANTEX TANK W/ PUMP BASIN, MAINTAIN 10' FROM THE FOUNDATION & 5' FROM FIELD TYP. BALLAST W/ 4 YDS OF CONCRETE MT MT TH#1 SLOPE 10%-15%FCO 10' UTILITY E A S E M E N T TCOSLOPE 10%-15%TH#2 VACAN T VACAN T Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP221416, Curtis Townsend, 01/20/23 1"=200' PROPERTY LINE PROOSE NEW WELL 50' RADIUS -VIOLA C I R - PROPOSED 3-BEDROOM HOUSE SCALE: DJRDRAWN: DATE: RABBIT CREEK VIEW & HEIGHTS BLK 4H, LT 8A Anchorage, Alaska TARAS ILNITSKIY 12/21/2022 SEPTIC SEPTIC PROPOSED 3-BEDROOM ADVANTEX SEPTIC WELL WELL WELL VACANT VACANT 10' UTILITY EASEMENT DESIGN CRITERIA: 0.5' EFFECTIVE 3 BDRM X 150 = 450 GPD SOILS = 450 GPD/2.3GPD/SF = 200 SF HORIZONTAL DISTRIBUTION 5.0' WIDE 50' LONG (1) MOUND +2.0' DEEP -8 (TH#1 & 2) -3.0 GM/ML ORG +1.0 MOUND OVER W/ 6" FILTER FABRIC & 2" INSULATION 24" OF MOA COURSE SAND ‘39&:‘#2& TOPSOIL & SEED WATER @ 3.0' OCT 2022 MIN. 24" OF SOIL COVER 3:1 +4.0 -3.0 24" OF TYP IIA CLASSIFIED FILL FOR TANK BUOYANCY 4,000 LBS CONCRETE (4YD) 50' & 100' WELL RADIUS ON NEIGHBORING LOTS, NO IMPACT MIN. 6" OF ROCK BELOW PIPESIDEWALL AREA, (50+5)*2*2( FILTER SAND) = 220 SF 2' W/ HORIZONTAL DIST. INTO THE TRENCH SIDEWALLS W/ 12" TOTAL OF SEWER ROCK REMOVE ALL ORGANICS (-3') DOWN TO THE ML LAYER ML LAYER 5.0' +2.0 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP221416, Curtis Townsend, 01/20/23 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP221416, Curtis Townsend, 01/20/23 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP221416, Curtis Townsend, 01/20/23 MUNICIPALITY OF ANCHORAGE ADVANCED WASTEWATER TREATMENT SYSTEM MAINTENANCE AND REPAIR AGREEMENT THIS MAINTENANCE AND REPAIR AGREEMENT, herein the "AGREEMENT" made and entered into as of this 7 Day of October of 20 22 , by and between Taras Ilnitskiy herein the "OWNER," and the Municipality of Anchorage, herein the "MUNICIPALITY", in accordance with Anchorage Municipal Code (AMC) 15.65.365. In consideration of the mutual covenants contained herein, the parties to this Agreement agree as follows: 1. Advanced Wastewater Treatment Systems. The Municipality grants permission to the Owner to utilize and operate an Advanced Wastewater Treatment System (AWWTS), described as Advantex Septic system located at (legal description) RABBIT CREEK VIEW & HEIGHTS GLK 4H LT 8A 2. Maintenance Repairs and Alterations. (Owner is required to read, understand and initial each section) Ti Throughout the term of this Agreement, the Owner shall enter into a service agreement with an AWWTS service and maintenance provider approved by the Municipality or the manufacturer's representative. The AWWTS shall be maintained in a satisfactory condition capable of performing as designed and producing treated septic effluent in accordance with the equipment's approval for operation in the Municipality. TI It shall be the responsibility of the Owner during the term of this Agreement to pay for all repair(s), maintenance, adjustment(s), replacement costs, and inspection costs. This includes an annual maintenance fee (typically $400 to $600). TI Owner agrees that only maintenance and repair personnel approved by the Municipality or the manufacturer's representative will inspect and make any necessary maintenance, repairs or permitted alterations to the system. TI Owner acknowledges that regular maintenance of an AWWTS reduces the potential failure of the system, which could include sewage backup and costly repairs or drainfield replacement. (rev. 05/18/2018) Page 1 of 3 Ti Owner acknowledges that the Municipality may request records of maintenance and repairs from the manufacturer's representative or maintenance provider. Ti Owner acknowledges that the fine for failing to maintain and repair an AWWTS may be assessed in accordance with AMC 14.60.030. TE Owner agrees to grant the Municipality reasonable access to test and inspect the AWWTS. The Municipality will give at least 24-hour notice. TI Owner agrees that any sale or transfer of title of the property will not occur without a new Certificate of On -Site Systems Approval. T! Owner agrees that the AWWTS installation and maintenance requirements as provided by the AWWTS vendor/installer and approved by the Municipality are the governing guidelines for the construction, maintenance and repair of the Owner's AWWTS. TI Owner agrees to maintain remote monitoring of the AWWTS as required by the AWWTS approval. 3. Term. The term of this Agreement shall begin on the date of approval by the Municipality to operate the installed system, or upon transfer of title, and shall continue while the AWWTS is operational or until title is transferred. 4. Nonwaiver. The failure of the Municipality at any time to enforce a provision of this Agreement shall in no way constitute a waiver of the provisions, nor in any way affect the validity of the Agreement or any part hereof, or the right of the Municipality thereafter to enforce every provision hereof. S. Amendment. This Agreement shall only be amended by authorized representatives of the Owner and Municipality. Any attempt to amend this agreement by either an unauthorized representative or unauthorized means shall be void. 6. Jurisdiction: Choice of Law. Any civil action arising from this Agreement shall be brought in the Superior Court for the Third Judicial District of the State of Alaska at Anchorage. The laws of the State of Alaska shall govern the rights and obligations of the parties under this Agreement. 7. Severability. Any provisions of this Agreement decreed invalid by a court of competent jurisdiction shall not invalidate the remaining provisions of the Agreement. (rev. 05/18/2018) Page 2 of 3 MUNICIPALITY OF ANCHORAGE ,I Development Services Department Phone: 907-343-7904 On-Site Water & Wastewater Section Fax: 907-343-7997 Parcel I.D. 020-551-22 Certificate of On -Site Systems Approval Expiration Date: 7/7/23 Legal description RABBIT CREEK VIEW & HEIGHTS BLK 4H LT8A Site address 7903 VIOLA CIR Current property owner(s) HOME RENEWAL CO XThe On-site system(s) is/are approved for 4 bedrooms Conditional approval for Comments or advisories: bedrooms, with the following stipulations: By: Original Certificate Date: 4/7/23 This Certificate of On -Site Systems Approval (COSA) is intended to demonstrate the subject system(s) is/are in substantial compliance with municipal code. The Municipality of Anchorage, Development Services Department (DSD) issues COSAs based upon representations provided by an independent professional engineer. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. ATTACHMENTS: COSA Checklist X Well Flow Advisory Absorption Field Advisory Nitrate Advisory Tank Age Advisory Arsenic Advisory Other COSA Approval_June 2022 MUHJUPJ UT7OF Development Services Department On -Site Water & Wastewater Section T 5 �1 Phone: 907-343-7904 Fax: 907-343-7997 Certificate of On -Site Systems Approval Application 1. GENERAL INFORMATION Parcel I.D. 020-551-22 Complete legal description Location (site address) RABBIT CREEK VIEW & HEIGHTS BLK 4H LT 8A 7903 VIOLA CIR Current property owner(s) TARAS ILNITSKIY 2. ON-SITE SYSTEMS SIZED FOR Ll BEDROOMS Day phone 3. TYPE OF WATER SUPPLY: ®❑ Private Well ❑ Private Well serving 2 dwelling units ❑ Private Well serving 3+ dwelling units ❑ Community Well or Public ❑ Water Storage 4. TYPE OF WASTEWATER DISPOSAL: ®❑ Private Septic ❑ Private Septic serving 2 dwelling units ❑ Holding Tank ❑ Community Septic or Public Sewer 5. SEPTIC TANK: ❑ Steel ❑ Plastic ❑ Concrete ❑ Fiberglass Age NEW - See advisory if steel older than 20 years 6. ABSORPTION FIELD: ❑ AWWTS ❑ Bed ❑ Deep Trench ❑ Wide Trench ❑ Seepage Pit Waiver request for: Expedited review requested: ®❑ Distance: By applying for this entitlement, this property is subject to inspection by municipal On-site staff to verify the accuracy of the information provided. COSA Fee $ 1 ZU Date of Payment COSA # 0-!�)G2 31 07 -r -T Waiver Fee $ Date of Payment Waiver # COSA Application—June 2022 COSA Checklist Legal Description: RABBIT CREEK VIEW & HEIGHTS BLK 4H LT8A parcel ID: 020-55122 If more than 1 well and/or septic system on lot, provide separate checklist. Structure served by this system _ A. WELL DATA X Well log is filed with Onsite (or attached) Date drilled 1/27/23 Total depth 200 ft Cased to 200 ft X Sanitary seal is functioning correctly FM Wires are properly protected Casing height (above ground) 24 in. Date of flow test for COSA NEW Well production at time of test 5+ gpm Water storage tank volume gallons Well disinfected for coliform test? Yes ❑ No 0 Coliform bacteria is Negative Nitrate 1.54 mg/L ❑ Nitrate less than MRL (ND) Arsenic ug/L F11111 Arsenic les than MRL (ND) Collected by MNA Static water level at beginning of test "RTES'"" ft. Date 2/2/23 Comments ARTESION WELL PACKER INSTALLED B. TANK DATA Measured operating fluid level in septic tank Date of pumping NEW ❑ Required maintenance completed, if AWWiS Comments: "ADVANTEX PRE-SET LEVELS D. ABSORPTION FIELD DATA Which system tested (date installed) NEW 0 ALL standpipes present per record drawing Total measured depth from grade 4.0 ft (max) Measured depth to pipe invert from grade 3.5 ft (min) ❑ N/A — pressurized field. ❑ Per record drawings, field is insulated. ❑� Monitor tubes go to bottom of effective. If not, state depth into effective _ ❑ Presoaked required if (Required if house vacant or field not used for more than 30 days prior to date of test) Gallons introduced gallons date Any rejuvenation treatment (past 12 months) If yes, enter date COSA Checklist June 2022 C. LIFT STATION ❑ Required maintenance completed, Age of lift station _ years Lift station material Comments: Adequacy test date NEW Results [C Pass Fluid depth prior to test _ in Water added _ gal New fluid depth _in Elapsed time _ min Final fluid depth _in Absorption rate _ gpd FIELD STATUS — POST RE Effective depth (per record drawinc Effective depth used 0 in Effective depth remaining 6 i 6 in E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well on lot) Septic Tank/Lift Station on Lot > 100' ,50,+ Community Sewer Manhole/Cleanout > 100' ❑ Yes if No _ ft g Yles if No It Neighboring Tank > 100' ❑o Yes if No _ ft Private Sewer/Septic Line > 25' Q Yes if No ft Absorption Field on Lot > 100' ❑ Yes if NoX50+ ft Holding Tank > 100' ❑ Y!es if No ft Neighboring Absorption Fields > 100' Animal Containment > 50' Q Yes if No ft Ri Yes if No ft _ Manure/Animal Excreta Storage > 100' Community Sewer Main > 75'❑ Yes if No _ ft Q Yes if No ft ❑ N/A — Served by Community Well (not on lot) or Public Water From Septic/Holding Tank and Absorption Field(s) on Lot to: (Please enter distances if less than required) Building Foundations > 10' Q Yes if No _ ft Surface Water > 100' Yes if No -ft Tank to Property Line > 5' R Yes if No _ ft Wells on Adjacent Lots: Field to Property Line > 10' ❑I. Yes if No _ ft Private Wells > 100' Yes if No _ ft Water Main > 10' Q Yes if No _ ft Community Wells > 200' ❑� Nes if No _ ft Water Service Line > 10' ❑� Yes if No _ ft If tank or field is under driveway comijnent below F. ENGINEER'S COMMENTS ADVANTEX SYSTEM WELL RADIUS >50'+ REQ. G. CERTIFICATION & STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines, indicates tha the on-site water supply and/or wastewater disposal system appears to comply with applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation, unless noted otherwise. Name of Firm MI L N kA %ci e vs.u.-t P. G. Phone 727 Engineer's Printed Name 4CAV� C� - Date -a M; t,1'L N K i RSCrJ� eA CE - 9469 COSA Checklist—June 2022 MUNICIPALITY OF ANCHORAGE ADVANCED WASTEWATER TREATMENT SYSTEM MAINTENANCE AND REPAIR AGREEMENT THIS MAINTENANCE AND REPAIR AGREEMENT, herein the "AGREEMENT" made and entered into as of this Day of ] '(VC \ 1 of 20 �3 , by and between be-C (� �,�Y�'l�ame�� , herein the "OWNER," and the Municipality of Anchorage, herein the "MUNICIPALITY", in accordance with Anchorage Municipal Code (AMC) 15.65.365. In consideration of the mutual covenants contained herein, the parties to this Agreement agree as follows: 1. Advanced Wastewater Treatment Systems. The Municipality grants permission to the Owner to utilize and operate an Advanced /Wastewater Treatment System (AWWTS), described as%S C/tC1(Ge (, fC,lec' located at (legal description) /n 4 19: -�— /'-r -e-,, Z /x- i, 2. Maintenance, Repairs and Alterations. (Owner is required to read, understand and initial each section) Throughout the term of this Agreement, the Owner shall enter into a service agreement with an AWWTS service and maintenance provider approved by the Municipality or the manufacturer's representative. The AWWTS shall be maintained in a satisfactory condition capable of performing as designed and producing treated septic effluent in accordance with the equipment's approval for operation in the Municipality. It shall be the responsibility of the Owner during the term of this Agreement to pay for all repair(s), maintenance, adjustment(s), replacement costs, and inspection costs. This includes an annual maintenance fee (typically $400 to $600). vFN�'J Owner agrees that only maintenance and repair personnel approved by the Municipality or the manufacturer's representative will inspect and make any necessary maintenance, repairs or permitted alterations to the system. 1�' Owner acknowledges that regular maintenance of an AWWTS reduces the potential failure of the system, which could include sewage backup and costly repairs or drainfield replacement. (rev. 05/18/2018) Page 1 of 3 l� Owner acknowledges that the Municipality may request records of maintenance and repairs from the manufacturer's representative or maintenance provider. Owner acknowledges that the fine for failing to maintain and repair an AWWTS may be assessed in accordance with AMC 14.60.030. nNIJ Owner agrees to grant the Municipality reasonable access to test and inspect the AWWTS. The Municipality will give at least 24-hour notice. Owner agrees that any sale or transfer of title of the property will not occur without a new Certificate of On -Site Systems Approval. Owner agrees that the AWWTS installation and maintenance requirements as provided by the AWWTS vendor/installer and approved by the Municipality are the governing guidelines for the construction, maintenance and repair of the Owner's AWWTS. Owner agrees to maintain remote monitoring of the AWWTS as required by the AWWTS approval. 3. Term. The term of this Agreement shall begin on the date of approval by the Municipality to operate the installed system, or upon transfer of title, and shall continue while the AWWTS is operational or until title is transferred. 4. Nonwaiver. The failure of the Municipality at any time to enforce a provision of this Agreement shall in no way constitute a waiver of the provisions, nor in any way affect the validity of the Agreement or any part hereof, or the right of the Municipality thereafter to enforce every provision hereof. 5. Amendment. This Agreement shall only be amended by authorized representatives of the Owner and Municipality. Any attempt to amend this agreement by either an unauthorized representative or unauthorized means shall be void. 6. Jurisdiction: Choice of Law. Any civil action arising from this Agreement shall be brought in the Superior Court for the Third Judicial District of the State of Alaska at Anchorage. The laws of the State of Alaska shall govern the rights and obligations of the parties under this Agreement. 7. Severability. Any provisions of this Agreement decreed invalid by a court of competent jurisdiction shall not invalidate the remaining provisions of the Agreement. (rev. 05/18/2018) Page 2 of 3 OWNER: By: (signature) Date: 1(t 2023 2(ccl - \J Yn \At"MCi (print name) STATE OF ALASKA ) ss. THIRD JUDICIAL DISTRICT ) The foregoing instrument was acknowledged before me this 14�' day of 20 TARY PUBLIC FOR ALASKA State of Alaska My Commission expires: NOTARY PUBLIC Peyton Tilton My commWon EvIres Dec 22, 2024 MUNICIPALITY: By: A (signature) (print name) Date: C( ? Title: (rev. 05/18/2018) Page 3 of 3