HomeMy WebLinkAboutBURLWOOD TR Bt t t Municipality of Anchorage On -Site Water and Wastewater Section • (907) 343-7904 Page 1 of ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP231042 PID Number: 020-531-01 Dwelling: ❑■ Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: ❑■ New ❑ Upgrade Name Eagles Nest Properties LLC ABSORPTION FIELD El Deep Trench 9Wide Trench El Bed El Mound Site Address 16630 Sandpiper Dr ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade (907) 345-0371 4 1 GPD/SF 4.6 / 4.8 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade 4.1/4.3 Ft. Gravel depth beneath pipe 0.5/0.5 Ft. Subdivision Block Lot Burlwood Tract B Fill added above original grade 3.9/4.2 Ft. Gravel length 61/61 Ft. Township Range Section Gravel width 5/5 Ft. Beds: Number of Lines N/A Distance between lines N/A Ft. SEPARATION DISTANCES To Septic AbsorptionHolding Lift Station Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Tank Line 610 Ftz 2 >6' Ft. Well >100' >1 QQ' N/A N/A >25' TANK ❑ Septic ❑ S.T.E.P. ❑ Holding ❑ Other Manufacturer Greer Capacity 1250 Gal. Surface Water > 1 oo' >1o0, N/A N/A Material Plastic Number of compartments 2 Lot Line >5' >10' N/A N/A NA Foundation >10' >10' N/A N/A LIFT STATION Ma er Capacity Gal. Remarks Trenches labeled south / north. Tank is a deep burial. Alarm location I installed by PIPE MATERIAL House to tank D3034 drainfield Tank to D3034 Installer Northern Excavation Drainfield D3034 CO/MTD3034 Inspector B. Schiller & M. Jakubisin BENCH MARK (Assumed elevation)100 ft Inspdection 15` 4/13/23 4/12/23 Location and description zea Top of Foundation @ NE Corner 3d 4°i ON-SITE WATER AND WASTEWATER SECTION APPROVAL Engineer's Stamp OF gCgt� Conditional Approval: Date •................... r% Septic Systef Benjamin Schiller CE 1259210/21/24. Approved - Date 0,llF'�FppROFESSI�NA�'�-��� 1\���\`�~� N te. this approval does not include well permit requirem nts. (Rev 057 ) Benjamin Schiller CE 12592R E GISTEREDPROFE S S I O N A L E N GINEER 1"=50' CO - CLEANOUT 2CO - DOUBLE CLEANOUT FCO - FOUNDATION CLEANOUT FS - FLOW SPLITTER VALVE MH - MANHOLE MT - MONITORING TUBE SV - SEPTIC VENT TH - TEST HOLE LEGEND TH#1 PERMIT # OSP231042 PID # 020-531-01 BURLWOOD, TRACT B A B FCO MH 55.4 SV 59.5 A B C C 5.4 2CO 62.6 CO1 69.2 MT1 67.9 CO2 37.6 38.5 39.0 69.7 69.0 19.4 FEET 0 50 100 FCO 4-BDRM HOME 10/2/24 PLAN AS-BUILT 1220 1180 1190 1210 1200 NEW WELL W/ 100' RADIUS CO2 CO4 CO3 CO1 MT1 MT3 MT4 MT2 1250-GAL SEPTIC TANK W/ 20' MANWAY 2CO (2x) 61' LONG x 5' WIDE, 6" EFFECTIVE DEPTH ABSORPTION TRENCH ALTERNATE SITE: CAT III ADVANCED TREATMENT 20' LONG x 5' WIDE, 0.5' EFFECTIVE DEPTH TRENCH FS D 14.8 D MT2 20.7 CO3 80.6 MT3 78.0 CO4 73.0 71.0 33.1 70.2 MT4 96.735.1 FS 69.941.9 CONFIRMATION PERK TEST 38.9 39.7 PROFILE AS-BUILT (NO SCALE) 91.8 86.6 92.9 98.6 FC O MH SV PERMIT # OSP231042 PID # 020-531-01 BURLWOOD, TRACT B 1250 GAL SEPTIC TANK 2C O 91.5 Benjamin Schiller CE 12592 R E GISTEREDPROFE S S I O N A L E N GINEER 10/21/24 97.7 FINISH GRADE 61' MT 3 TH # 1 GROUNDWATER @ 82.5 2/28/2023 86.7 89.2 CO 3 CO 4 77.0 86.7 89.2 93.5 ORIGINAL GRADE MT 4 NORTH TRENCH 98.1 FINISH GRADE 61' MT 1 TH # 1 GROUNDWATER @ 83.2 2/28/2023 87.6 90.1 CO 1 CO 2 77.7 87.6 90.1 94.2 ORIGINAL GRADE MT 2 SOUTH TRENCH DRAINFIELD ROCK MOA APPROVED SAND 89.689.6 DRAINFIELD ROCK MOA APPROVED SAND 88.788.7 MUNICIPALITY OF ANCHORAGE Development Services Department Phone: 907-343-7904 On-Site Water & Wastewater Section Fax: 907-343-7997 Pump Installation Log Well Drilling Permit Number: _______________ Date of Issue: ____-____-____ Parcel Identification Number: ____-____-____ Legal Description Block Lot Property Owner Name & Address: Pump Installation Date: _____-_____-_____ Pump Intake Depth Below Top of Well Casing: __________ feet Pump Manufacturer’s Name: ___________________________ Pump Model: _____________________________________ Pump Size: ____________hp Pitless Adapter Burial Depth: _________ feet Pitless Adapter Manufacturer’s Name: _________________________ Pitless Adapter Installer: ____________________________ Well Disinfected Upon Completion? XX Yes No Method of Disinfection: _____________________________ Comments: Pump Installer Name: __________________________________ Company: ___________________________________________ Mailing Address: ______________________________________ City: ___________________ State: __________Zip: _________ Attention: The pump installer shall provide a pump installation log to On-site within 30 days of pump installation. Alpine Drilling & Enterprises Well Log Permit Number: #SW231042 Date of Issue: 3-29-23 Parcel Identification Number: 02053101000 Date Started: 7-14-23 Date Completed: 7-15-23 Is well located at approved permit location? x Yes ❑ No Legal Description: Burlwood Tract B Property Owner Name & Address: Colony Builders, Inc 9420 Vanguard Drive Anchoraqe, Alaska 99507 Borehole Data: Depth (ft) Method of Drilling z air rotary ❑ cable tool Soil Type, Thickness & Water Strata From To Casing type: steel stick up 0 2 Wall Thickness:.250 inches siltyfill organics and sit 2 6 6 9 Diameter: Finches Depth: 141 feet Liner Type: Diameter: _ inches Depth: _ feet gravelly silt 9 33 Casing stickup above ground: 2 feet silty gravel H2O 33 37 Static water level (from ground level): Z feet gravelly silt silt 37 45 48 52 Pumping level: 140 feet after 2 hours pumping 10 gpm Recovery Rate: 10 gpm sandy gravelly silt 52 136 Method of Testing: air li silty water sand & gravel 136 141 Well Intake Opening Type: x Open End ❑ Open Hole ❑ Screened Start feet Stopped feet ❑ Perforations Start feet Stopped _ feet Grout Type: bentonite chips Volume: 7 De the Start 0 feet Stopped 35 feet Pump: Intake Depth feet Pump size _ hp Brand Name Well Disinfected Upon Completion? x Yes ❑ No Method of Disinfection: chlorine tablets Comments: Well Driller: Alpine Drilling & Enterprises PO Box 110496 Anchorage AK 99511 LEGAL DESCRIPTION: PERFORMED FOR: DATE:PARCEL ID#: SOILS LOG AND PERCOLATION TEST 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 DEPTH (feet) PERK TEST 2 DATE READING START TIME NET TIME(minutes) DEPTH toWATER NET DROP PERCOLATION RATE: (MIN/INCH) (inches)(inches) DATE OF MONITORING WAS WATER ENCOUNTERED? DEPTH TO WATER AFTER MONITORING IF YES @ WHAT DEPTH? 2.1 4/12 1 2 3 4 5 6 GM (SILTY GRAVEL) Professional Engineers Stamp: NO BURLWOOD SUB. TRACT B 4/12/2023 020-531-01 NORTHERN EXCAVATION 2:54 1 0 16 OB 9:00 Benjamin Schiller CE 12592 R E GISTEREDPROFE S S I O N A L E N GINEER 10/2/24 PERC TEST LOCATION TECHNICIAN:M. Jakubisin 7 0 16 - - - COMMENTS: 6" DIAMETER TEST HOLE PRESOAKED PRIOR TO TESTING SITE PLAN 6 0 16 USCS SOIL CLASSIFICATION WAS VISUALLY DETERMINED 3:05 1 0 1610:00 6 6 16 5 6 16 3:15 1 0 1610:00 6 0 16 5 0 16 3:27 1 0 1610:00 5 14 16 4 14 16 3:38 1 0 1610:00 5 12 16 4 12 16 3:49 1 0 1610:00 5 12 16 4 12 16 MUNICIPALITY OF ANCHORAGE 1»cnt On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road r �a;ivJ y'% Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite V 111 Department On -Site Water & Wastewater System Permit Permit Number: OSP231042 Effective Date: 3/29/2023 Work Type: WellSeptic Initial Expiration Date: 3/28/2024 Tax Code Number: 02053101000 Site Legal Address: BURLWOOD TR B G:3240 Site Mailing Address: Owner: EAGLES NEST PROPERTIES LLC Lot Size in Sq Ft: 1746340 Design Engineer: FORGE ENGINEERING Total Bedrooms: 4 This permit is for the construction of: Q Disposal Field CJI Septic Tank ❑ Holding Tank ❑ Privy Q Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Issued By: Date: Date: 31Z Community Development Department Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On -Site Water & Wastewater Program ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 020-531-01 Property owner(s) Eagles Nest Properties LLC Day phone (907) 345-0371 Mailing address 1120 Huffman Road 24 - 822, Anchorage, AK 99515 Site address Legal description (Sub'd., Block & Lot) Burlwood Tract B Legal description (Township, Range & Section) Lot Size 1,746,340 Sq. Ft. Number of Bedrooms 4 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (N all that apply) Absorption Field ❑X Initial ❑X Single Family (SF) ❑X Septic Tank ❑X Upgrade El(w/wo AD U) Holding Tank El Renewal❑ (D) ElRenewal Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑X Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: /-7Waiver Fees: Date of Payment: 3 29 ZA 2 Date of Payment: Receipt Number: 6 3 Receipt Number: Permit No. 0,522 7�> log -2- Waiver No. Permit App_'-'-:. :' ., c- March 28, 2023 MOA Development Services, On-Site Water & Wastewater Program 4700 Elmore Rd Anchorage, AK 99507 Subject: Burlwood Tract B Septic system design Dear On-Site Services Engineer: The owner of the above lot intends to build a 4-bedroom home on the property, so we are submitting this permit application for the construction of a new well and septic system. The attached site plan identifies the location of the home as well as the propo sed well, septic location and alternate site. No conflicts exist between this proposed system and any other well or septic system, whether on this lot or adjacent lots. The ground surface on the lot slopes fairly uniformly to the north. In the area where the septic system is located, the slopes range from 10-15%. There are no slopes greater than 25% within 50 feet downslope of either the primary or alternate site. Contours are shown on the site plan showing the grade and direction of flow. Stormwater drainage will not impact this septic system. The new trench will be constructed parallel to the slope as much as possible. Wells on this and adjacent lots are shown. The new system will be a minimum of 100’ from all wells and surface water, and more than 5’ away from the septic tank. The alternate site is located more than 6’ away. Please refer to the attached test hole log, plan and profile pages for the septic design. If this design is followed, there will be no adverse impacts to adjacent properties. Sincerely, Benjamin Schiller, PE Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP231042, Deb Wockenfuss, 03/29/23 10' T&E EASEMENT Benjamin Schiller CE 12592R EGISTEREDPROFES S I O N ALENGINEER 1"=100' CO - CLEANOUT 2CO - DOUBLE CLEANOUT FCO - FOUNDATION CLEANOUT FS - FLOW SPLITTER VALVE MH - MANHOLE MT - MONITORING TUBE SV - SEPTIC VENT TH - TEST HOLE LEGEND TH#1 BURLWOOD, TRACT B FEET 0 100 200 FCO 4-BDRM HOME 1240 3/28/23 SEPTIC PLAN 1250 1230 1220 1160 1170 1180 1190 1210 1200 WETLANDS PROPOSED WELL CO CO CO CO MT MT MTMT 1250 GAL SEPTIC TANK 2CO 2x60' LONG x 5' WIDE, 0.5' EFFECTIVE DEPTH ABSORPTION TRENCH ALTERNATE SITE: CAT III ADVANCED TREATMENT 20' LONG x 5' WIDE, 0.5' EFFECTIVE DEPTH TRENCH FS Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP231042, Deb Wockenfuss, 03/29/23 BURLWOOD, TRACT B TYPICAL TRENCH SECTION (NO SCALE) NOTES: 1. GRADE AREA OVER TRENCH TO DRAIN AWAY 2. PROVIDE 3' OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2' WITH 2" OF INSULATION 3. CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY Benjamin Schiller CE 12592R EGISTEREDPROFES S I O N ALENGINEERDESIGN FACTORS:SYSTEM REQUIREMENTS: 600 GPD PEAK FLOW PERK RATE: <1 MIN/IN APPLICATION RATE: 1 GPD/SF 5-WIDE SHALLOW TRENCH SYSTEM 1250-GAL SEPTIC TANK BOTTOM OF TRENCH: 4' BELOW GRADE FLOW LINE ELEVATION: 3.5' BELOW GRADE TOP OF TRENCH: AT GRADE 600 GPD / 1 GPD/SF / 5' WIDE * 1.0 RED FACTOR [0.5 DEEP]= 120 LF TRENCH REQUIRED 4" PERFORATED PVC HOLES DOWN 9/10/22 DRAINFIELD ROCK GEOTEXTILE FABRIC SAND LINER 6" 6" 2' 3' 5' 6" Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP231042, Deb Wockenfuss, 03/29/23 LEGAL DESCRIPTION: PERFORMED FOR: DATE: PARCEL ID#: SOILS LOG AND PERCOLATION TEST 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 DEPTH (feet) TEST HOLE 1 DATE READING START TIME NET TIME (minutes) DEPTH to WATER NET DROP PERCOLATION RATE: (MIN/INCH) (inches)(inches) DATE OF MONITORING WAS WATER ENCOUNTERED? DEPTH TO WATER AFTER MONITORING IF YES @ WHAT DEPTH? 0.34 2/20/23 1 2 3 4 5 6GM (SILTY SANDY GRAVEL) Professional Engineers Stamp: NO BURLWOOD SUB. TRACT B 2/20/23 020-531-01 CLIENT 1:30 6 OB 00:53 Benjamin Schiller CE 12592R EGISTEREDPROFE S S I O N ALENGINEER9/24/22 PERC TEST LOCATION TECHNICIAN: M. Jakubisin 0 - 11' 2/28/23 COMMENTS: 6" DIAMETER TEST HOLE PRESOAKED PRIOR TO TESTING SITE PLAN 6 0 16 USCS SOIL CLASSIFICATION WAS VISUALLY DETERMINED BOH 6 01:15 0 6 0 16 6 01:35 0 6 0 16 6 01:48 0 6 0 16 6 01:56 0 6 0 16 6 01:59 0 6 0 16 7 6 02:01 0 6 0 16 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP231042, Deb Wockenfuss, 03/29/23 MUNICIPALITY OF ANCHORAGE i-',\, Development Services Department_ �� Phone: 907-343-7904 On -Site Water & Wastewater Section —� Fax: 907-343-7997 Certificate of On -Site Systems Approval Parcel I.D. 020-531-01-000 Expiration Date: Legal description BURLWOOD TR B Site address 16630 SANDPIPER DR Anchorage AK 99516 Current property owner(s) EAGLES NEST PROPERTIES LLC 10/11/2025 X The On-site system(s) is/are approved for 4 bedrooms Conditional approval for bedrooms, with the following stipulations: Comments or advisories: In 0 Original Certificate Date: 11/7/2024 is Certificate of On -Site Systems Approval (COSA) is intended to demonstrate the subject system(s) is/are in substantial compliance with municipal code. The Municipality of Anchorage, Development Services Department (DSD) issues COSAs based upon representations provided by an independent professional engineer. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. ATTACHMENTS: COSA Checklist X Well Flow Advisory Absorption Field Advisory Nitrate Advisory Tank Age Advisory Arsenic Advisory Other COSA ApprovaIjune 2022 MUNICIPALITY OF ANCHORAGE Development Services Department Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Certificate of On -Site Systems Approval Application 1. GENERAL INFORMATION Parcel I.D. 020-531-01 Complete legal description Burlwood, Tract B Location (site address) 16630 Sandpiper Dr, Anchorage, AK, 99516 Current property owner(s) Eagle Nest Properties LLC Day phone (907) 345-0371 2. ON-SITE SYSTEMS SIZED FOR 4 BEDROOMS 3. TYPE OF WATER SUPPLY: 0 Private Well ❑ Private Well serving 2 dwelling units ❑ Private Well serving 3+ dwelling units ❑ Community Well or Public ❑ Water Storage 4. TYPE OF WASTEWATER DISPOSAL: 0 Private Septic ❑ Private Septic serving 2 dwelling units ❑ Holding Tank ❑ Community Septic or Public Sewer 5. SEPTIC TANK: ❑ Steel 0 Plastic ❑ Concrete ❑ Fiberglass Age NEW - See advisory if steel older than 20 years 6. ABSORPTION FIELD: ❑ AWWTS ❑ Bed ❑ Deep Trench ■❑ Wide Trench ❑ Seepage Pit Waiver request for: Expedited review requested: ❑ Distance: By applying for this entitlement, this property is subject to inspection by municipal On-site staff to verify the accuracy of the information provided. COSA Fee $ '0 Waiver Fee $ Date of Payment 11105 �Z`� Date of Payment COSA # D5 C 2 `i Waiver # COSA Application_ June 2022 N/A N/A N/A Benjamin Schiller, P.E. (907) 522-7773 TRACT B BURLWOOD SUBDIVISION AS BUILT 124 E 7th Avenue Anchorage, Alaska 99501 (907) 306-8104 mail@S4AK.com Land Surveying Land Development Consultants Subdivision Specialists Construction Surveying S4 Group BUILDING DETAIL SCALE: 1" = 20' 10/29/2024