Loading...
HomeMy WebLinkAboutCANYON VIEW ESTATES BLK 2 LT 6 CANYON VIEW ESTATES Block 2 Lot 6 #021-021-52 VI.. VJ/ IVJ / Municipality of Anchorage On -Site Water and Wastewater Section • (907) 343-7904 Page 1 of 3 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP231044 PID Number: 021-021-52 Dwelling: ❑■ Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: ❑■ New ❑ Upgrade Name Hultquist Homes ABSORPTION FIELD ❑ Deep Trench X Wide Trench ❑ Bed ❑ Mound site Address 13836 Canyon Road ❑ Other Phone Number of Bedrooms Soil Rating depth from original grade 5 1.2 GPD/SF JTotal 2.0 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade 1.5 Ft. Gravel depth beneath pipe 0.5 Ft. Subdivision Block Lot Canyon View Estates 2 6 Fill added above original grade 2.0 Ft. Gravel length 130 Ft. Township Range Section Gravel width 5 Ft. Beds: Number of Lines NA Distance between lines NA Ft. SEPARATION DISTANCES To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Tank Line 650 Ftz 2 @ 65' 6.9 Ft. Well 100'+ 100'+ NA NA 25'+ TANK Septic ❑ S.T.E.P. ❑ Holding ❑ Other Manufacturer Greer Tank Capacity 1,500 Gal. Surface Water 100'+ 100'+ NA NA Material Number of compartments Lot Line 5'+ 101+ NA NA NA Plastic 2 Foundation 10'+ 10'+ NA NA LIFT STATION Manufacturer Capacity Remarks Tank installed above water table. Gal. Alarm location Electrical installed by Installer PIPE MATERIAL House to tank 3034 Tank to 3034 drainfield Brownson Brothers Drainfield 3034 CO/MT3034 Inspector PES BENCH MARK (Assumed elevation) 100 ft Inspect ectioes: 1s' 11/1/23 11/2/23 Location and description aro 11/3/23 2nd 4h 11/6/23 Bottom of house trim, nearest corner ON-SITE WATER AND WASTEWATER SECTION APPROVAL Engineer's Stamp Conditional Approval: Date �•(�••... ... .. ..... 'eanri ie CE 8149 Septic System Xg Approved %` PP / � Date •ARID' Not is approval does not include well permit requireme ts. VI.. VJ/ IVJ / PA N N O N E E N G S V C , L L C ( C . I . 1 0 8 8 ) N S EW PANNONE ENG SVC, LLC (C.I. 1088) SOILS LOG COMMENTS: Test hole excavated by BROWNSON BORTHERS. PERFORMED BY: PES. I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDLINES IN EFFECT ON THE DATE OF THIS TEST. ·1.4 (min/inch) ·6" ·2 FT AND 3 FT Certified Drilling Log OWNER OF LAND: Hultquist ADDRESS: 13836 Canyon Rd. Anchorage, AK 99516 LEGAL DESCRIPTION Canyon View Estates BLK 2 L6 DATE: 11/17/23 PERMIT NUMBER: OSP231044 DATE OF ISSUE: 4/17/23 TAX IDENTIFICATION NUMBER 02102152000 Is well located at approved permit location: Yes No Method of Drilling: air rotary cable tool Depth of Well: 280’ Casing Type: Steel Wall thickness .250 inches Diameter: 6 inches, depth 124 feet Liner type Static Water Level: 120 feet Recovery Rate 4 gpm gph Method of Testing Air Well Intake Opening Type: open end open hole Screened Start feet Stopped Perforations Start feet Stopped Grout Type: Bentonite Volume: 50 lbs. Depth: from 2 feet, to 42 feet Well Disinfected Upon Completion: yes no Method of Disinfection: Chlorine 50 PPM Comments: Bore Hole Data Depth From To 0 2 Casing Stickup 2 4 Fill 4 6 Overburden 6 21 Silty sand and gravel 21 81 Tight silty sand and gravel 81 108 Hardpan with clay 108 122 Broken bedrock 122 228 Fractured bedrock brown 228 280 Gray with quartz seams Drillers Name: Cole Sullivan ATTENTION: It is the responsibility of the property owner to submit a copy of the well log to the proper authority. Municipality of Anchorage: Department of Health & Human Services and/or Department of Environmental Conservation. MatSu Borough: Department of Environmental Conservation. p DOC CO dba �gI« �& COLE ULLIVAN WATER W P.O. Box 670269, Chugiak, AK 99567 IBB -2759 www.suilivanwaterwells.com Pump Installation Log Well Drilling Permit Number: SW '2 �OA4 Date of Issue r Parcel Identification Number: 2-10 -2-15-1 Q0 Legal Description Property Owner Name & Address 01 Pump Installation Date: Pump Intake Depth Below Top of Well Casing: Pump manufacturer's Name:jq,� K r Pump Model: (0 P P—b i'P IPump Size: I- IPitless Adapter Burial Depth: 12, Pitless Adapter Installer: 5 f,�N jjS c -, n F-) v- o S - Disinfected Upon Completion? ® yes ❑ no 1 Method of Disinfection: Chlorine 50 PPM Comments: Pitless Manufacturer:i , I Pump Installers Name: Sullivan Water Wells feet hp feet Attention: The pump installer shall provide a pump installation log to the DSD within 30 days of pump installation. o OF q ��°gyp f CD Benjamin Holmstrom 0 O LS 118708 N ' C ��i°fessiono\ �-oo doh s s � \ 6> �?O�. �o°a \ 110, 20' T&E Easement 'tee uE 2016-013102-0 \ 01"3 fb ProposedPaved Driveway \ \ �0 Drawn by: ZBB Job: 2023-25 Checked by. SC Field Book: N/A Legend: Manhole\ s.o 12.0' / Existing Set Rebar with Cop ,o �0 N House q sps• Found Rebar Cleanout . Survey Certification: I hereby certify that a Mortgagee's Well Inspection was performed on the described property. 4.00' o' Notes: It is the owner's responsibility to determine the existence of any easements, covenants, or restriction which 4 N 50.41 V It is the contractor's responsibility to check top of foundation _ grade & building setbacks in relation to property lines and easements. Parcel No. 02102152000 Address: NHN Canyon Road so Lot 6 Block 2 88,363 sf 2.029 cc / �O O N z / y /�O 0 R7 c 7�. 792 opo 36• F Zoning CE R-10 1 / Setbacks Front 10' Side 25' Back 10' Drawn by: ZBB Job: 2023-25 Checked by. SC Field Book: N/A Legend: ASbullt Set Rebar with Cop Legal AL. Monument Description: Lot 6, Block 2, Found Rebar Canyon View Estates Subdivision . Survey Certification: I hereby certify that a Mortgagee's Well Inspection was performed on the described property. Septic Stand Pipe Notes: It is the owner's responsibility to determine the existence of any easements, covenants, or restriction which are not on the recorded subdivision plat. It is the contractor's responsibility to check top of foundation _ grade & building setbacks in relation to property lines and easements. Parcel No. 02102152000 Address: NHN Canyon Road Drawn by: ZBB Job: 2023-25 Checked by. SC Field Book: N/A Legend: Set Rebar with Cop O AL. Monument Found Rebar Monument Well Septic Stand Pipe Scale: 1" = 60' Plat: 2021-65 Pavement Overhang 0 Wood Deck Grid: SW2942 Date: 1 MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Water & Wastewater System Permit Permit Number: OSP231044 Work Type: WellSeptic Initial Tax Code Number: 02102152000 Site Legal Address: CANYON VIEW ESTATES BLK 2 LT 6 G:3042 Site Mailing Address: 13836 CANYON RD, Anchorage Owner: HULTQUIST HOMES INC Design Engineer: PANNONE ENGINEERING SERVICES This permit is for the construction of: Effective Date: Expiration Date: Lot Size in Sq Ft: Total Bedrooms: 1 V'I'Cllr ( l t)el>arrrtier7r 4/17/2023 4/16/2024 88363 Q Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy Q Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Received By: S 5� 0 /D l i Issued By: (=0 N vr"�'l'10,.. "2"L. Date: Date: % Z 5 ��1�UHU °AUTi O " HCHORAGZ Community Development Department Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On -Site Water & Wastewater Program ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 021-021-52 Property owner(s) Hultquist Homes, Inc. Mailing address 12570 Old Seward Highway Anchora Site address NHN Canyon Road _ Day phone _ e, AK 99515 Legal description (Sub'd., Block & Lot) Canyon View Estates Block 2 Lot 6 Legal description (Township, Range & Section) Lot Size 88363 Sq. Ft. Number of Bedrooms 5 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (N all that apply) Absorption Field X❑ Initial X❑ Single Family (SF) X❑ Septic Tank X❑ Upgrade El(w/wo ADU) Duplex (D) El Holding Tank ❑ Renewal ❑ Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well X❑ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: $ S 20 Waiver Fees: Date of Payment: 3o 202 3 Date of Payment: Receipt Number: O 0 5 5- Receipt Number: Permit No.— �S %� 7 I Opt -H-- Waiver No. Permit App_".;- : • Pannone Engineering is S LLC Steven R. Pannone, Principal Registered Professional Engineer E-mail: steve@panengak.com 15 June 2023 Municipality of Anchorage Development Services Department On -Site Water & Wastewater Program 4700 Elmore Road P.O. Box 196650 Anchorage, Alaska 99519 Subject: Canyon View Estates Block 2 Lot 6 Well & Septic System Permit Request Septic System Design Narrative This is a design narrative for a permit to install an initial well and septic system on the subject property. The proposed system will serve a proposed five -bedroom (5) house. Currently the lot is undeveloped. This lot and surrounding lots are served by private wells. Currently there are no wells within 100 feet of the proposed system. 1. Soils: A test hole was performed on this lot by Pannone Engineering Services, LLC in March of 2023. Groundwater was not observed during the excavation of the test hole, and bedrock was not encountered. Groundwater was observed in the test hole monitor tube after 7 -days at a level of (6.0') below grade on (05/25/2023). Based on the results of the percolation tests, overall soils appearance, and the selection of the proposed drain field; an application rate of 1.2 gallons/day/square feet was used for a conventional wastewater system in the area of the test hole. 2. Soil Absorption System Design. a. See Sheet 1 of the design package. 3. Surface Water: There are several mapped drainages on the subject property that do not pass surface water. Please see the attached site plan. 4. Topography: See attached site plan for area topography. Mailing: P.O.Box 1807, Palmer, AK 99645 Telephone: (907) 745-8200 FAX: (907) 745-8201 Page 2 of 2 S. Drawing Markings: The Drawings are marked "For MOA Review Only". When written notification that the review is complete and no further comments are received from MoA On -Site Department, the note will be removed and "For Construction" drawings will be issued. The proposed installation will not affect the future development of this or the surrounding lots. If you have any questions or concerns, please contact me at (907) 745-8200. Sincerely, S TRP Steven R. Pannone, P.E. F. ASCE Owner/Civil Engineer Mailing: P.O.Box 2807, Palmer, AK 99645 Telephone: (907) 745-8200 FAX: (907) 745-8201 V �v 133HS 91566 Ad `3OVKHONd Nd-ld IllIS tito�£Zdso OVMJ NO,INVO NHN :31lS ON ' 11o;o uwo ona ONI `SIWOH 1SIf1O nH le 30 ZS-lZ0-tzo lZ0 }�" d0`d 03H33HO ON '0.1'd •••• •••• 91 Z9 'iSJ MIIIA NO,INVO waa/ori NMvao 31VOS •LOZ8-SbL L06 XV3 OOZE-StiL L06 3NOHd £ZOZ/£l/90 � 9b966 SIV 'a3p]Vd LOST X08 'O•d a30a0 30NVHO 31VU SNO1SIAM 8804 'e'O) O'll OAS ON3 3NONNVd :S31ON a / � N od / t 1 \ ti o Z�0 00 84Q�Od\ l o I u-�-zz4Zo m N, \ 2 \ , / RUO xeo m as O�(iL�scy J QRZ N Oe J�Wa 02 W/ 2 x ti 0 2 Q U') Q m // 1 0LQ c, hO �NU �cn 1J N o W UZ w= U Q- V�j Z k U Q J� Q� -K F O\ o �o�~QWO �� cn O - ��r Iu� Ln� WQ 0. Gu c�QZ�jQ1W ,w-1 3;, z o n C� z J tl � Z O o�N�Wu� o �� o"'�J Wu� �j�oW�Q aw w cn z�Wm LIJ 12 \1 O�� �W �N�N �N ZI�i`t0� I I moo oo�� o ` R W O C7 Z k W O CST �� 3 y I-= O z pN0-Q � O LLJ I- l` �t O Z z Q a F- CC Z y 4i1-7,ClW �W Obi �� I--z3-I ��oN�QQ�Z �Q C��� QQ�� o� I >w�X'�o�o° v) � m�U JQ J "�J (� •� Q��„ � J kJ 3 y � W ��OQiuO�a? d�� ��OQO��? MIM aWOUrni-°} Q Z1�� coQ co :z -h Q NI7. Q L,Ia._�F— z J0 z zS-lz0-lz0 I Sl N -- -4 ivn SNOIS1A32f O H 1,0 =z Z W wwz ¢w0� (n Q New of ¢ O 0 Z N LL Np�Wm �g•Mz no ox of w = LLI LLJ F- C a 1n. . . r 11. ZI p p N W tz L I ¢ IQ Q�la a Ir 3 K a �, Q O W Z w 3 3 LC C'.C'. ^ 3 Id W CD O W ¢ Z Z QWz �. � C'=O x 0 xU r a a za Z a w wo o.1 �oo IIo�IIvOw z¢ N W 91566 Ab `19VJOHONV GVO0 ] N0,M3 NHN :ALIS 'DNI `SAMH isinoiim 9� ZO '1S]l M3IA NO.INVO LLZ8-ZLZ (L06) XV3 8LZB-LZ (L06) 3NOHd 0(966 )LV '30VN1 HONV V96ZOL X08 -O'd (880L TO) 311 OAS 9N3 3NONNVd vi w x F -- cc O Z O z 3 0 m O s y V1 F W w 2 2 O U WWN WW W ¢O jOJ J JO F N F OJ axQO J Zn W (Z.�m Wa O F' ¢ w QZ ¢ z WULF ¢ 0 w _ s0 '' w¢ azo �F wFa7 v z� Oy�� 3 �- aZ� z QZa Ka m F - VI J � F U J N K Z�� H i� .1 E W Z Z w Q 3 O� U o Q O 0 a, O y Z N o ¢ S m w� o zo ¢ o o -mi -n g fno o3z_ F 3 ww�z mZ Q Wa a�i¢ O°� ozviz o w CFo z z� z~ oo wQ ww 0`-^ O rif U U WC�WaO y� 2 o U JJ-0� F F O ¢ zv)X N �tn� OUQ ...IZ W N� 0<6Z N O QZ w�H W O a J 0O MF O W z ¢ W O %`¢; 800 L -M7 W W V. W JO N Q O� 3 WW O K Q O m U J W F OQ {¢� �O 3' �wrWiz�-dam— WZ o Z� oaOJ� Um _' zjF p N WMNO Z¢ W�W wW; VI WQa'W O� w�wom�WOF oo a po `-'vJi�� owQ �� ¢ 1i dw az o a Z~N 0 } O U O N m W U 0 0 > Z Q U Z W o Z O Q J W O m O W Z� W O Z Z W Z WQ Q NUr 1+_Q 1'm001-7 O OQ �0 ¢0 W J NQ > W ZW Zm Z mQ it o Z F7}w� 2aoNQO WF¢ aF w QQ �F. oqo z1x x3o a OZWW�o Fw �Nz �W x Ovi¢J�o wz a ¢a acs w � xX��" Z 1n O Jow o �wzOJ 3 UN Z awzaW zdJOp ¢� U ..lU�UQ Qri ozE Z QN> awm WWI �Q YQo oZ WaN3wwo� O��UJO4z* W,Wi w Jz ~MocWi o 3 oQ N1n n=i Q Ww�c}i�t� Zfzn opa 20V10<Rm oKmz, WOJ�QU0 F0 Zw K j Canyon View B2 L6 Subject: 3/23/2023 Originator:ACP Checker: SITE PARAMETERS 1. No angle of repose on backfill material Weight of Water 62.4 lb/ft3 Weight of Soil 120.0 lb/ft3 Tank Bury Depth 4 ft TANK DIMENSIONS Diameter 64.0 in Diameter 5.33 ft Length 17 ft Area 22.34 ft2 Volume 379.78 ft3 Weight 0 lb Manholes Yes Percentage of Tank in Groundwater 100% BOUYANT FORCES (weight of the displaced water) 23698 lbf UP RESISTING FORCES (weight of soil & tank) Is Backfill Material Saturated?YES Volume of Manholes 25 ft3 Volume of Soil 338 ft3 (Volume of Soil over Tank minus Volume of Manholes) Weight of Soil 19442 lb DOWN NET FORCE ON TANK -4257 lb UP Ballast Required, See Below Septic Tank Buoyancy Check Job Number:SRP Job Name: Buoyancy Check 2500-gallon STEP Tank ASSUMPTIONS 2. 120 lb/ft3 backfill material 3. Tank is empty 4. Tank is completely submerged. Buoyancy Control: 1.See site plan for STEP Tank buoyancy control RESISTING FORCES (weight of concrete blocks) Height 2.0 ft Width 2.0 ft Length 6.0 ft Volume 24.0 ft3 Weight of Concrete 145.0 lb/ft3 Weight of Blocks 1982.4 lb Number of Blocks 4 ea SEPTIC NET FORCE ON TANK 3673 lb DWN Design OK Canyon View B2 L6 Subject: 3/23/2023 Originator:ACP Checker: ASSUMPTIONS SITE PARAMETERS 1. No angle of repose on backfill material Weight of Water 62.4 lb/ft3 2. 125 lb/ft3 backfill material 3. Vault is empty Weight of Soil 120.0 lb/ft3 Figure 1: Buoyancy Collar Diagrams Pump Vault Dimensions Diameter 24.0 in 2.00 ft Radius 1.00 ft Height 8 ft Area 3.14 ft2 Volume 25.13 ft3 BOUYANT FORCES (weight of the displaced water) 1568 lb UP RESISTING FORCES (weight of soil Buoyancy Collar based on 1ft ring around entire vault) Volume of Concrete 9.4 ft3 Unit Weight of Concrete 145 lb/ft3 Weight of Collar 778 lb RESISTING FORCES WEIGHT OF SOIL (based on truncated cone) Volume of Soil 326.7 ft3 Volume of soil minus volume of pump vault Weight of Soil 18819.4 lb NET FORCE ON PUMP VAULT 18030 lb DWN Design OK Auxillary Pump Vault Job Number:SRP Job Name: Buoyancy Check Pump Vault Buoyancy Check MUNICIPALITY OF ANCHORAGE Development Services Department Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Certificate of On -Site Systems Approval Parcel I.D. 021-021-52-000 Expiration Date: 11/21/2024 Legal description CANYON VIEW ESTATES BILK 2 LT 6 Site address 13836 CANYON RD Anchorage AK 99516 Current property owner(s) HULTQUIST HOMES INC X The On-site system(s) is/are approved for 5 bedrooms Conditional approval for bedrooms, with the following stipulations: Comments or advisories: Original Certificate Date: 12/12/2023 This Certificate of On -Site Systems Approval (COSA) is intended to demonstrate the subject system(s) is/are in substantial compliance with municipal code. The Municipality of Anchorage, Development Services Department (DSD) issues COSAs based upon representations provided by an independent professional engineer. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. ATTACHMENTS: COSA Checklist X Well Flow Advisory Absorption Field Advisory Nitrate Advisory Tank Age Advisory Arsenic Advisory Other COSA ApprovaIjune 2022 Eli rL �z =m , I W_ " IT, FIN Development Services Department On -Site Water & Wastewater Section Phone: 907-343-7904 Fax: 907-343-7997 Certificate of On -Site Systems Approval Application 1. GENERAL INFORMATION h Parcel I.D. 02102152000 Complete legal description Canyon View Estates B2 L6 Location (site address) 13836 Canyon Rd Anchorage Current property owner(s) HUItquist Homes Day phone 2. ON-SITE SYSTEMS SIZED FOR 5 BEDROOMS 3. TYPE OF WATER SUPPLY: X Private Well ❑ Private Well serving 2 dwelling units ❑ Private Well serving 3+ dwelling units ❑ Community Well or Public ❑ Water Storage 4. TYPE OF WASTEWATER DISPOSAL: ❑■ Private Septic ❑ Private Septic serving 2 dwelling units ❑ Holding Tank ❑ Community Septic or Public Sewer 5. SEPTIC TANK: 0 Steel ❑ Plastic ❑ Concrete ❑ Fiberglass Age new - See advisory if steel older than 20 years 6. ABSORPTION FIELD: ❑ AWWTS ❑ Bed ❑ Deep Trench X Wide Trench ❑ Seepage Pit Waiver request for: Expedited review requested: ❑E Distance: By applying for this entitlement, this property is subject to inspection by municipal On-site staff to verify the accuracy of the information provided. COSA Fee $ Waiver Fee $ Date of Payment 12 I r zob2 Date of Payment COSA # o3c 2 3 V 65- Waiver # COSA Application—June 2022 COSA Checklist_June 2022 COSA Checklist Legal Description: Parcel ID: If more than 1 well and/or septic system on lot, provide separate checklist. Structure served by this system ____ A. WELL DATA Well log is filed with Onsite (or attached) Date drilled Total depth ft Cased to ft Sanitary seal is functioning correctly Wires are properly protected Casing height (above ground) in. Date of flow test for COSA Static water level at beginning of test ft. Well production at time of test gpm Water storage tank volume gallons Well disinfected for coliform test? Yes No Coliform bacteria is Negative Nitrate mg/L Nitrate less than MRL (ND) Arsenic ug/L Arsenic less than MRL (ND) Collected by Date Comments __________________________________________________________________________________ B. TANK DATA Measured operating fluid level in septic tank Date of pumping Required maintenance completed, if AWWTS Comments: C. LIFT STATION Required maintenance completed Age of lift station years Lift station material Comments: D. ABSORPTION FIELD DATA Which system tested (date installed) ALL standpipes present per record drawing Total measured depth from grade ft (max) Measured depth to pipe invert from grade ft (min) N/A – pressurized field. Per record drawings, field is insulated. Monitor tubes go to bottom of effective. If not, state depth into effective Presoaked required if (Required if house vacant or field not used for more than 30 days prior to date of test) Gallons introduced gallons date Any rejuvenation treatment (past 12 months) If yes, enter date Adequacy test date Results Pass Fluid depth prior to test in Water added gal New fluid depth in Elapsed time min Final fluid depth in Absorption rate gpd FIELD STATUS – POST RECOVERY Effective depth (per record drawings) in Effective depth used in Effective depth remaining in Comments/Deficiencies: COSA Checklist_June 2022 E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well on lot) Septic Tank/Lift Station on Lot > 100’ Yes if No ft Neighboring Tank > 100’ Yes if No ft Absorption Field on Lot > 100’ Yes if No ft Neighboring Absorption Fields > 100’ Yes if No ft Community Sewer Main > 75’ Yes if No ft Community Sewer Manhole/Cleanout > 100’ Yes if No ft Private Sewer/Septic Line > 25’ Yes if No ft Holding Tank > 100’ Yes if No ft Animal Containment > 50’ Yes if No ft Manure/Animal Excreta Storage > 100’ Yes if No ft N/A – Served by Community Well (not on lot) or Public Water From Septic/Holding Tank and Absorption Field(s) on Lot to: (Please enter distances if less than required) Building Foundations > 10’ Yes if No ft Tank to Property Line > 5’ Yes if No ft Field to Property Line > 10’ Yes if No ft Water Main > 10’ Yes if No ft Water Service Line > 10’ Yes if No ft Surface Water > 100’ Yes if No ft Wells on Adjacent Lots: Private Wells > 100’ Yes if No ft Community Wells > 200’ Yes if No ft If tank or field is under driveway comment below F.ENGINEER’S COMMENTS G.CERTIFICATION & STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines, indicates that the on-site water supply and/or wastewater disposal system appears to comply with applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation, unless noted otherwise. Name of Firm Phone Engineer’s Printed Name Date 2023.12.11