Loading...
HomeMy WebLinkAboutMILE HI #1 BLK 9 LT 4t t t MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Water & Wastewater System Permit Permit Number: OSP231066 Work Type: WellSeptic Initial Tax Code Number: 05020141000 Site Legal Address: MILE HI #1 BLK 9 LT 4 G:0058 Site Mailing Address: Owner: WOODS JOHN R & LESLIE J Design Engineer: FORGE ENGINEERING This permit is for the construction of: Effective Date: Expiration Date Lot Size in Sq Ft: Total Bedrooms: ��»cnt llepartment 5/11/2023 5/10/2024 46115 Q Disposal Field Z Septic Tank ❑ Holding Tank ❑ Privy Q Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing 55 LAe to O/ e- 'E -no Date: Issued By: Al Date: �g�/ Z� 3 MUNICIPALITY OF ANCHORAGE Community Development Department e:3 Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On -Site Water & Wastewater Program ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 050-201-41 Property owner(s) John Woods Mailing address 371 Mala Street, Wahiawa, HI 96786 Day phone 808-295-2903 Site address NHN Lynx Way, Anchorage, AK Legal description (Sub'd., Block & Lot) Mile Hi #1 Block 9 Lot 4 Legal description (Township, Range & Section) Lot Size 46,115 Sq. Ft. Number of Bedrooms 3 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (® all that apply) Absorption Field ❑x Initial 0 Single Family (SF) ❑X (w/wo AD U) Septic Tank ❑x Upgrade ❑ (D) El Holding Tank ❑ RenewalDuplex ❑ Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑x Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE /WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. V L'v (Signature of property owner or authorized agent) Permit/Rush Fees: ZO Date of Payment: '�rL Receipt Number: 025 ,21p Permit No. Os 0 Z 310 Permit App_-'- : "L.A; Waiver Fees: Date of Payment: Receipt Number: Waiver No. April 13, 2023 MOA Development Services, On-Site Water & Wastewater Program 4700 Elmore Rd Anchorage, AK 99507 Subject: Mile Hi #1 B9 L4 Septic system design Dear On-Site Services Engineer: The owner of the above lot intends to build a 3-bedroom home on the property, so we are submitting this permit application for the construction of a new well and septic system. The attached site plan identifies the location of the home as well as the proposed well, septic locati on and alternate site. No conflicts exist between this proposed system and any other well or septic system, whether on this lot or adjacent lots. The ground surface on the lot slopes steeply in general, although there is a flatter section on the northeast corner of the lot. That is where the home and driveway will be located. The septic system will be just below that to the southeast of the building, where the slopes are closer to 30% and drop off from there. Although the trench will be built on a 30% slope, it does meet the exceptions for steep slope construction, with the exception that there are slopes greater than 46% within 100’ of the disposal field and alternate site. Instead, please refer to the Slopes Profile which shows that the 47% angle of effluent influence will not reach the slope surface for over 50’. Stormwater drainage will not impact this septic system. The new trench will be constructed parallel to the slope as much as possible. Wells on this and adjacent lots are shown. The new system will be a minimum of 50’ from all wells and surface water, and more than 5’ away from the septic tank. The alternate site is located more than 6’ away. Please refer to the attached test hole log, plan and profile pages for the septic design. If this design is followed, there will be no adverse impacts to adjacent properties. Sincerely, Benjamin Schiller, PE Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP231066, Deb Wockenfuss, 05/11/23 O/ E O/ E O/ E O/ E O/ E O/ E Benjamin Schiller CE 12592REGISTEREDPROFESSION A L E N GINEER 1"=50' 25' LONG x 5' WIDE, 1' EFFECTIVE DEPTH ABSORPTION TRENCH 1,500-GAL CAT III ADVANTEX FAP 2.0 SYSTEM CO - CLEANOUT 2CO - DOUBLE CLEANOUT FCO - FOUNDATION CLEANOUT FS - FLOW SPLITTER VALVE MH - MANHOLE MT - MONITORING TUBE SV - SEPTIC VENT TH - TEST HOLE LEGEND CO MT TH#1 MILE HI #1, BLOCK 9 LOT 4 FEET 0 50 100 FCO NOTE: MAINTAIN 10' SEPARATION FROM FOUNDATION AND PROPERTY LINE WITH TANK AND TRENCH. MAINTAIN 5' SEPARATION FROM TANK TO TRENCH. ALL SURROUNDING LOTS ARE VACANT- NO CONFLICTS WITH WELLS OR SEPTIC SYSTEMS. LYNX WAY 3 - B D R M H O M E 1570 3/27/23 B R O W N I E D R I V E 1560 1550 1540 1530 1520 1510 1500 1490 14801470 14601450 1440 1430 1420 SHED OVERHEAD POWER LINES 25' SETBACK 25' SETBACK UNNAMED STREAM 15' UTILITY EASEMENTSEPTIC PLAN ALTERNATE SITE BOT TRENCH @ 11' BELOW GRADE 2CO CO MT PROPOSED WELL MAINTAIN 50' SEPARATION FROM STREAMBED NO SEPTIC SYSTEMS WITHIN 100' OF PROPERTY BOUNDARY Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP231066, Deb Wockenfuss, 05/11/23 MILE HI #1, BLOCK 9 LOT 4 TYPICAL TRENCH SECTION (NO SCALE) NOTES: 1. GRADE AREA OVER TRENCH TO DRAIN AWAY 2. PROVIDE 3' OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2' WITH 2" OF INSULATION 3. CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY Benjamin Schiller CE 12592REGISTEREDPROFESSION A L E N GINEER 4" PERFORATED PVC (HOLES DOWN) DRAINFIELD ROCK 5' 4'-6" 1' DESIGN FACTORS:SYSTEM REQUIREMENTS: 450 GPD PEAK FLOW PERK RATE: 7.1 MIN/IN APPLICATION RATE: 5.0 GPD/SF 5' WIDE SHALLOW TRENCH SYSTEM 1500-GAL CAT III ADVANCED TREATMENT SYSTEM BOTTOM OF TRENCH: 6' BELOW GRADE FLOW LINE ELEVATION: 5' BELOW GRADE 450 GPD / 5.0 GPD/SF / 5' WIDE * 0.88 (RED FACTOR) = 15.8 LF TRENCH REQUIRED (25 LF SPECIFIED) GEOTEXTILE FABRIC 3/27/23 6" ADD ADDITIONAL 6" FILL TO ENSURE NO DEPRESSION AFTER SETTLEMENT 3' Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP231066, Deb Wockenfuss, 05/11/23 1500.00 1505.00 1510.00 1515.00 1520.00 1525.00 1530.00 1535.00 1540.00 1545.00 1550.00 1500.00 1510.00 1520.00 1530.00 1540.00 1550.00 0+00.00 0+50.00 0+75.00 1"=10' SLOPE CROSS SECTION SEPTIC TRENCH Benjamin Schiller CE 12592REGISTEREDPROFESSION A L E N GINEER 8/26/2022 46 % AN G LE OF EF F L U E N T INF L U E N C E ALTERNATE SITE 6.0 FEET 0 10 20 30.3% 53.6 % 73.6 % 6.0 11.0 MILE HI #1, BLOCK 9 LOT 4 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP231066, Deb Wockenfuss, 05/11/23 LEGAL DESCRIPTION: PERFORMED FOR: DATE: PARCEL ID#: SOILS LOG AND PERCOLATION TEST 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 DEPTH (feet) TEST HOLE 1 DATE READING START TIME NET TIME (minutes) DEPTH to WATER NET DROP PERCOLATION RATE: (MIN/INCH) (inches)(inches) DATE OF MONITORING WAS WATER ENCOUNTERED? DEPTH TO WATER AFTER MONITORING IF YES @ WHAT DEPTH? 7.06 8/30/22 1 2 3 GM (SILTY SANDY GRAVEL) Professional Engineers Stamp: No Mile Hi #1, block 9 Lot 4 8/26/22 050-201-41 John Woods 1:03 0 1:34 2:05 OB 30 Benjamin Schiller CE 12592REGISTEREDPROFESSION A L E N GINEER 9/24/22 PERC TEST LOCATION TECHNICIAN: L. Tidwell 4 4 16 - None 9/6/22 COMMENTS: 6" DIAMETER TEST HOLE PRESOAKED PRIOR TO TESTING SITE PLAN 4 4 16 USCS SOIL CLASSIFICATION WAS VISUALLY DETERMINED 030 4 3 16 4 3 16 030 4 4 16 4 4 16 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP231066, Deb Wockenfuss, 05/11/23 FLA (signature) Date: C'� SS /1 e w) p� (print name) '1 4 STATE OF A&ASKA Ct, ���� � OI���I.� j 55. T ) The foregoing instrument was acknowledged before me this gTday of \10` 20M, by GrYson K Fonseca �))NKfip/V�� C9. NOTARY My Commission expires: DEC Q ;may 4 t�26 PUBLIC Notary Public, First Judicial Circuit No. 22-266 State of Hawaii ' My commission expires: DEC 2026 t MUNICIPALITY: LBy (/�' ''7t ie � Date: .(print name) Title: — ON.. ... Doc. Date: # Pages: ; �5 K �V Circuit t ' Name: Y ". a+ ; 0NOTARY Doc. Description: PUBLIC No. 22-266 :' tu Date NO RY CERTIFICA` -ION �'T •• P�,' ,9 (rev. 05/18/2018) Page 3 of 3