Loading...
HomeMy WebLinkAboutRABBIT CREEK VIEW & HEIGHTS BLK 5H LT 24A RABBIT CREEK VIEW & HEIGHTS Block 5H Lot 24A #020-561-31 Municipality of Anchorage On -Site Water and Wastewater Section • (907) 343-7904 Page 1 of 3 ON -SITE WASTEWATER INSPECTION REPORT Permit Number: OSP231088 PID Number: 020-561-31 Dwelling: ❑■ Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: 9 New ❑ Upgrade Name Deas Bode ABSORPTION FIELD ❑ Deep Trench ❑■ Wide Trench ❑ Bed El Mound Site Address 8144 Marino Drive ❑ Other Phone (907) 250-4989 Number of Bedrooms 4 Soil Rating Total depth from original grade 6.0 GPD/SF +0.5 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade +1.0 Ft. Gravel depth beneath pipe 0.5 Ft. Subdivision Block Lot Rabbit Creek V&H 5H 24A Fill added above original grade 4.6 Ft. Gravel length 2 0. 0 Ft. Township Range Section Gravel width 5.0 Ft. Beds: Number of Lines N/A Distance between lines N/A Ft. SEPARATION DISTANCES To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Tank Line 100 Ftz 1 N/A Ft. Well >50' >50' N/A N/A >25' TANK ❑ Septic ❑ S.T.E.P. ❑ Holding ❑■ Other Manufacturer Greer Capacity 1530 Gal. Surface Water >50' >50' N/A N/A Material Plastic Number of compartments 2 Lot Line >5' > 10' N/A N/A NA Foundation I > 1 0' > 1 0' 1 N/A N/A LIFT STATION Manufacturer Greer Capacity 540 Gal. I Remarks Alarm location NW Corner by garage I Electrical installed by Home Owner Installer PIPE MATERIAL House to tank D3034 Tank to drainfield D3034 D&K Construction Drainfield D3034 CO/MT D3034 Inspector M. Jakubisin BENCH MARK (Assumed elevation) 100 ft Inspdection ` 10/11/23 10/16/23 Location and description 2nd N E corner of house 3rd 4m ON -SITE WATER AND WASTEWATER SECTION APPROVAL Engineer's Stamp s�G / , Conditional Approval: Date v' `i ��Q '9cp,���1� f 4 iH 'chiller Septic System�enc25 Approved Date b �-�Z ��'�rF� . 12/6/24 •��` tl1t� pROFESSiO4� Note: this approval does not include well permit requirements. (Kev ub/uz/ia) 1 0 ' 1 0 ' U T I L I T Y E A S E M E N T ( T Y P ) Benjamin Schiller CE 12592R E G ISTEREDPROFE S S I O N A L E N GINEER 1"=40' CO - CLEANOUT 2CO - DOUBLE CLEANOUT FCO - FOUNDATION CLEANOUT BBP - BIOBARRIER POD MH - MANHOLE MT - MONITORING TUBE SV - SEPTIC VENT TH - TEST HOLE LEGEND PERMIT # OSP231088 PID # 020-561-31 RABBIT CREEK V&H, BLOCK 5H LOT 24A A B FCO 18.9 MH1 18.1 SV1 23.7 B BBP 22.9 2CO 30.6 CO1 61.0 26.3 35.1 41.9 44.5 45.9 33.6 FEET 0 40 80 PLAN AS-BUILT 6/16/26 D I A N E D R I V E 4-BDRM HOME 1220 1215 1210 1205 1225 50' SURFACE WATER SETBACK SURFACE WATER MEASURED AT TIME OF INSPECTION 4-BEDROOM BIOMICROBICS AWWTS 20' LONG x 5' WIDE, 0.5' EFFECTIVE DEPTH ABSORPTION TRENCH TH#1 ALTERNATE SITE EXISTING WELL MAR I N O D R I V E WELL LOCATION UNCLEAR, BUT AT A MINIMUM SEPARATION IS >50' FROM PROPOSED SEPTIC SYSTEM EXISTING SEPTIC SYSTEM > 100' FROM WELL SV2 20.745.0 MT1 62.4 CO2 60.6 34.5 49.5 MT2 60.748.2 MT1 CO1 MT2 CO2 2COSV1 MH1 BBPSV2 A FCO ALARM LOCATION BENCH MARK PROFILE AS-BUILT (NO SCALE) PERMIT # OSP231088 PID # 020-561-31 RABBIT CREEK V&H, BLOCK 5H LOT 24A 1530 GAL PLASTIC SEPTIC TANK Benjamin Schiller CE 12592 R E GISTEREDPROFE S S I O N A L E N GINEER 6/16/26 95.1 90.8 95.4 98.5 MH SV 2C O 95.7 95.3 91.4 96.0 99.1 MH 95.2 FC O 540 GAL PLASTIC SEPTIC TANK BIOBARRIER POD 2" FOAM INSULATION 2" FOAM INSULATION 98.1 FINISH GRADE 20' DRAINFIELD ROCK MT TH#1 GROUNDWATER @ 91.8 5/2/23 94.0 94.5 CO CO 86.5 94.0 94.5 93.5 ORIGINAL GRADE MT 2" FOAM INSULATION MOA APPROVED SAND 92.5 • W,A Development Services Department Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Permit Number: #_231088 Date of Issue: 5/24/23 Parcel Identification Number: Date Started: 5/30/23 Date Completed: 5/31/23 Is well located at approved permit location? Yes FE-1 No E] Legal Description: Rabbit Creek View & Heights BLK 5H LT 24A Property Owner Name & Address: Bode Deas Borehole Data: Depth (ft) Soil Type, Thickness & Water Strata From To Caing Stick Up 0 2 Fill 2 4 Silt & Gravel (Boney) 4 10 Silt & Gravel 10 50 Wet Silt & Gravel 50 53 Coarse Gravel W/ H2O 53 54 water quality tested 5/2026 Water Sample Results: Arsenic: ND Nitrates: ND Total Coliform Bacteria: Neg ug/L mg/L colonies/100mL Method of Drilling F-01 air rotary R cable tool Casing type: Steel Wall Thickness: .250 inches Diameter: 6 inches Depth: 54 feet Liner Type: none Diameter: inches Depth: feet Casing stickup above ground: 2 feet Static water level (from ground level): 25 feet Pumping level: feet after hours pumping gpm Recovery Rate: Z__gpm Method of Testing: air lift Well Intake Opening Type: xQ Open End F-1 Open Hole ❑ Screened Start feet Stopped feet F-1 Perforations Start feet Stopped feet Grout Type: Rentonite Volume: 2 Bags Depth: 20 Feet Start 0 feet Stopped 20 feet Well Disinfected Upon Completion? No Method of Disinfection: tabs Comments: Well Driller: Johnny Kay FX1 M Company: Hefty Drilling Inc. Mailing Address: PO BOX 112130 Anch AK 9� Attention: The well driller shall provide a well log to the On -site Water and Wastewater Section within 30 days of completion. MUNICIPALITY OF ANCHORAGE Development Services Department _ __� Phone: 907-343-7904 On -Site Water & Wastewater Section ` Fax: 907-343-7997 Pump Installation Log Well Drilling Permit Number: 231088 _ Date of Issue: 5 24 23- - Parcel Identification Number: 020 -561 -31 Legal Description Block Lot Property Owner Name & Address: Rabbit Creek View & Heights 5H 24A Deas Bode I Pump Installation Date: 12 -27 -23 Pump Intake Depth Below Top of Well Casing: Pump Manufacturer's Name: Grundfos I Pump Model: 1 OSQE07-200 I Pump Size: '75 hp IPitless Adapter Burial Depth: 10 feet Uzi PE (t i+ G f t `t Uk. 5' feet IPitless Adapter Manufacturer's Name: Campbell B10 Type I Pitless Adapter Installer: Hefty Drilling Well Disinfected Upon Completion? X Yes ❑ No Method of Disinfection: Tabs I Comments: IPump Installer Name: Johnny Kay I Company: Hefty Drilling, Inc. Mailing Address: P.O. Box 112130 City: Anchorage State: AK Zip: 99511 Attention: The pump installer shall provide a pump installation log to On -site within 30 days of pump installation. ∆ ∆ Taylor L. Dosch No. 189892 R E GISTEREDPROFESSIO N A L L A N D S U RVEYOR MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Water & Wastewater System Permit Permit Number: OSP231088 Work Type: WellSeptic Initial Effective Date: Expiration Date Tax Code Number: 02056131000 Site Legal Address: RABBIT CREEK VIEW & HEIGHTS BLK 5H LT 24A G: Site Mailing Address: Owner: BODE DEAS M & KARLENA Design Engineer: FORGE ENGINEERING This permit is for the construction of: Q Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy ilzcnt S 1° Department 5/24/2023 5/23/2024 Lot Size in Sq Ft: 17458 Total Bedrooms: 4 Q Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Received By: r—O(L-C7 -I Issued By: Date: Date: S `� �Z3 GLV UHC CC PDAL.0TV OF „HCH0 --------------- -, Community Development Department Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On -Site Water & Wastewater Program ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 020-561-31 Property owner(s) Deas Bode Day phone 907-250-4989 Mailing address 7800 Marino Dr, Anchorage, AK 99516 Site address NHN Marino Dr Legal description (Sub's., Block & Lot) Rabbit Creek V&H B5H L24A Legal description (Township, Range & Section) Lot Size 17458 Sq. Ft. Number of Bedrooms 4 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (® all that apply) Absorption Field ❑x Initial R Single Family (SF) x❑ Septic Tank x❑ Upgrade El(w/wo AD U) Holding Tank ElRenewal ElDuplex (D) El Privy ❑ Multiple Dwellings ❑ (SF and/or D) Private Well ❑x Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. k (Signature of property owner or authorized agent) Permit/Rush Fees: c6 2- D Waiver Fees: Date of Payment: s� V Z,-, Date of Payment: Receipt Number: 0 Receipt Number: Permit No. 03P2 )osS Waiver No. Permit App_::- : :'-.,:c May 3, 2023 MOA Development Services, On-Site Water & Wastewater Program 4700 Elmore Rd Anchorage, AK 99507 Subject: Rabbit Creek V&H B5H L24A-NHN Marino Septic system design Dear On-Site Services Engineer: The owner of the above lot intends to build a 4-bedroom home on the property, so we are submitting this permit application for the construction of a new well and septic system. The attached site plan identifies the location of the home as well as the propo sed well, septic location and alternate site. No conflicts exist between this proposed system and any other well or septic system, whether on this lot or adjacent lots. Contours are shown on the site plan showing the grade and direction of flow. Stormwater drainage will not impact this septic system. The new trench will be constructed parallel to the slope as much as possible. Wells on this and adjacent lots are shown. The new system will be a minimum of 50’ from all wells and surface water, and more than 5’ away from the septic tank. The alternate site is located more than 6’ away. This new septic system will be a BioBarrier system, which is an Advanced Category III treatment system. The application rate for this system with a perk rate just over 30 min/in is 6 GPD/SF, and there are reduced horizontal and vertical separation requirements to groundwater. The layout and components will be per manufacturer’s instructions as approved by the Municipality. Please refer to the attached test hole log, plan and profile pages for the septic design. If this design is followed, there will be no adverse impacts to adjacent properties. Sincerely, Benjamin Schiller, PE Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP231088, Curtis Townsend, 05/24/23 1 0 ' 1 0 ' U T I L I T Y E A S E M E N T ( T Y P ) Benjamin Schiller CE 12592REGISTEREDPROFESSION A L E N GINEER 1"=50' CO - CLEANOUT 2CO - DOUBLE CLEANOUT FCO - FOUNDATION CLEANOUT FS - FLOW SPLITTER VALVE MH - MANHOLE MT - MONITORING TUBE SV - SEPTIC VENT TH - TEST HOLE LEGEND PID # 020-561-31 RABBIT CREEK V&H, BLOCK 5H LOT 24A FEET 0 50 100 SEPTIC PLAN 5/3/23 D I A N E D R I V E 4-BDRM HOME 1220 1215 1210 1205 1225 50' SURFACE WATER SETBACK SURFACE WATER 4-BEDROOM BIOMICROBICS AWWTS 20' LONG x 5' WIDE, 0.5' EFFECTIVE DEPTH ABSORPTION TRENCH EXTENT OF MOUND TH#1 ALTERNATE SITE PROPOSED WELL MAR I N O D R I V E WELL LOCATION UNCLEAR, BUT AT A MINIMUM SEPARATION IS >50' FROM PROPOSED SEPTIC SYSTEM EXISTING SEPTIC SYSTEM > 100' FROM WELL Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP231088, Curtis Townsend, 05/24/23 RABBIT CREEK V&H BLOCK 5H LOT 24A TYPICAL TRENCH SECTION (NO SCALE) NOTES: 1. GRADE AREA OVER TRENCH TO DRAIN AWAY 2. PROVIDE 3' OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2' WITH 2" OF INSULATION 3. CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY Benjamin Schiller CE 12592REGISTEREDPROFESSION A L E N GINEER 4" PERFORATED PVC (HOLES DOWN) DRAINFIELD ROCK 5' 6" 1' DESIGN FACTORS:SYSTEM REQUIREMENTS: 600 GPD PEAK FLOW PERK RATE: 34 MIN/IN APPLICATION RATE: 6.0 GPD/SF 5' WIDE TRENCH SYSTEM 2070-GAL ADVANCED TREATMENT TANK BIOBARRIER SYSTEM BOTTOM OF TRENCH: 0.5' ABOVE GRADE FLOW LINE ELEVATION: 1.0' ABOVE GRADE TOP OF TRENCH: 3.5' ABOVE GRADE 600 GPD / 6.0 GPD/SF / 5' WIDE * 1.0 RED FACTOR = 20 LF TRENCH REQUIRED GEOTEXTILE FABRIC 6" 5/2/23 2' MOA APPROVED SAND 6" Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP231088, Curtis Townsend, 05/24/23 LEGAL DESCRIPTION: PERFORMED FOR: DATE: PARCEL ID#: SOILS LOG AND PERCOLATION TEST 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 DEPTH (feet) TEST HOLE 1 DATE READING START TIME NET TIME (minutes) DEPTH to WATER NET DROP PERCOLATION RATE: (MIN/INCH) (inches)(inches) DATE OF MONITORING WAS WATER ENCOUNTERED? DEPTH TO WATER AFTER MONITORING IF YES @ WHAT DEPTH? 34 7/16/20 1 2 3 GC (CLAYEY GRAVEL) Professional Engineers Stamp: NO RABBIT CREEK V&H B5H L24H 7/16/2020 020-561-31 D.BODE 2:50 0 3:20 3:50 1' OB 30 Benjamin Schiller CE 12592REGISTEREDPROFESSION A L E N GINEER PERC TEST LOCATION TECHNICIAN: L.TIDWELL 15 16 - 1.7 5/2/23 COMMENTS: SITE PLAN 15 16 USCS SOIL CLASSIFICATION WAS VISUALLY DETERMINED 5/2/23 30 30 0 1416 0 1416 1416 1416 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP231088, Curtis Townsend, 05/24/23 Maintenance Check List Date �ea S r) 06 Client 6;- -22- - Z Items to be checked and documented: N • Was this cheduled inspectio or an Alarm response • Check control panel for history and note /F? V^� L e�4 • Check Blower performance in Manuel modeyc9091 • Check discharge pump flow in Manuel mode, note if CIP needed • Is a deep clean required, pull membrane & perform 24hr deep cleaning i1G • Check Ftoat Tree for slime or build up L--(96L ado • Test alarm function, ok? 0---No • Effluent Temperature • Check solids In first tank or compartment INA i n t • Any additives needed? • Check field for effluent in standpipes, how many inches v • Perform site walk around, power and Manhole lids fastened • Was any work billable or was it all warrantee 1\0 Q t)vt j1 '6-t" ( Technician l wt C—�Mv Ld MUNICIPALITY OF ANCHORAGE Development Services Department Phone: (907)343-7904 On -Site Water & Wastewater Section Fax: (907)343-7997 Certificate of On -Site Systems Approval OSC261198 Parcel ID 020-561-31 Legal description RABBIT CREEK VIEW Site address 8144 MARINO DR Expiration Date: HEIGHTS BLK 5H LT 24A Current property owner(s) BODE DEAS M & KARLENA X The On -site system(s) is/are approved for 4 bedrooms Conditional approval for bedrooms, with the following stipulations: Comments or conditions: By: Curtis Townsend Original Certificate Date: 6/26/2026 This Certificate of On -Site Systems Approval (COSA) is intended to demonstrate the subject system(s) is/are in substantial compliance with municipal code. The Municipality of Anchorage, Development Service Department (DSD) issues COSAs based upon representations provided by an independent professional engineer. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's submittal. ATTACHMENTS: COSA Checklist X Well Flow Advisory Absorption Field Advisory Nitrate Advisory Tank Age Advisory Arsenic Advisory Other MUNICIPALITY OF ANCHORAGE • A Development Services Department Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Certificate of On -Site Systems Approval Application 1. GENERAL INFORMATION Parcel I.D. 020-561-31 Complete legal description RABBIT CREEK V&H, BLOCK 5H LOT 24A Location (site address) 8144 Marino Dr, Anchorage, AK, 99516 Current property owner(s) DeaS & Karlena Bode Day phone (907) 250-4989 2. ON -SITE SYSTEMS SIZED FOR 4 BEDROOMS 3. TYPE OF WATER SUPPLY: ❑■ Private Well serving # 1 dwelling units ❑ Other Non-public well as regulated by MOA ❑ Water Storage ❑ Community Well or Public 4. TYPE OF WASTEWATER DISPOSAL: W Private Septic ❑ Private Septic serving 2 dwelling units ❑ Holding Tank ❑ Community Septic or Public Sewer 5. SEPTIC TANK: ❑ Steel I Plastic ❑ Concrete ❑ Fiberglass Age 2.6 - See advisory if steel or fiberglass older than 20 years 6. ABSORPTION FIELD: ❑■ AWWTS ❑ Bed ❑ Deep Trench ■❑ Wide Trench ❑ Seepage Pit Waiver request for: Expedited review requested: ❑ Distance: By applying for this entitlement, this property is subject to inspection by municipal On -site staff to verify the accuracy of the information provided. COSA Fee $ II Date of Payment COSA# Waiver Fee $ Date of Payment Waiver # COSA Application_Apr2025.doc COSA Checklist_May2025.docx COSA Checklist Legal Description: Parcel ID: If more than 1 well and/or septic system on lot, provide separate checklist. Structure served by this system ____ A. WELL DATA Well log is filed with Onsite (or attached) Date drilled Total depth ft Cased to ft Sanitary seal is functioning correctly Wires are properly protected Casing height (above ground) in. Date of flow test for COSA Static water level at beginning of test ft. Well production at time of test gpm Water storage tank volume gallons Well disinfected for coliform test? Yes No Coliform bacteria is Negative Nitrate mg/L Nitrate less than MRL (ND) Arsenic ug/L Arsenic less than MRL (ND) Collected by Date Comments __________________________________________________________________________________ B. TANK DATA Measured operating fluid level in septic tank Date of pumping Required maintenance completed, if AWWTS Comments: C. LIFT STATION Required maintenance completed Age of lift station years Lift station material Comments: D. DISPOSAL FIELD DATA Which system tested (date installed) ALL standpipes present per record drawing Total measured depth from grade ft (max) Measured depth to pipe invert from grade ft (min) N/A – pressurized field. Per record drawings, field is insulated. Monitor tubes go to bottom of effective. If not, state depth into effective Presoaked required if (Required if house vacant or field not used for more than 30 days prior to date of test) Gallons introduced gallons date Any rejuvenation treatment (past 12 months) If yes, enter date Adequacy test date Results Pass Fluid depth prior to test in Water added gal New fluid depth in Elapsed time min Final fluid depth in Absorption rate gpd FIELD STATUS – POST RECOVERY Effective depth (per record drawings) in Effective depth used in Effective depth remaining in Comments/Deficiencies: COSA Checklist_May2025.docx E. SEPARATION DISTANCES From Well on Lot to:(Please enter distances if less than required) Septic Tank/Lift Station on Lot > 100’ Yes if No ft Neighboring Tank > 100’Yes if No ft Disposal Field on Lot > 100’Yes if No ft Neighboring Disposal Fields > 100’ Yes if No ft Sewer Line/Main > 100’ Yes if No ft Sewer Manhole/Cleanout > 100’ Yes if No ft Sewer Service/Septic Line > 25’Yes if No ft Holding Tank > 100’ Yes if No ft Animal Containment > 50’Yes if No ft Manure/Animal Excreta Storage > 100’ Yes if No ft N/A – Served by Community Well (not on lot) or Public Water From Septic/Holding Tank and Disposal Field(s) on Lot to:(Please enter distances if less than required) Tank to Foundation > 10’Yes if No ft Field to Foundation > 10’ Yes if No ft Tank to Property Line > 5’ Yes if No ft Field to Property Line > 10’ Yes if No ft Water Main/Service Line > 10’Yes if No ft Surface Water > 100’Yes if No ft Wells on Adjacent Lots: Wells > 100’Yes if No ft Community Wells > 200’Yes if No ft If tank or field is under driveway comment below F. ENGINEER’S COMMENTS G. CERTIFICATION & STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines, indicates that the on-site water supply and/or wastewater disposal system appears to comply with applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation, unless noted otherwise. Name of Firm Phone Engineer’s Printed Name Date 611Y civil a ctttart arisilig from this Agreement shall be the, Third Judicial District of the Stets of Alaska t of shall govern theriglits and obligations ot` the this Agreement decreed in arliz by a countof coil i e-teit Ic rcollrlululg Provisions of the Agreement, aI o1 M\ NER: By — _(signature) Y►^'�'(print nante) STATE: OF ALASKA ) ss. TI IIRD JUDICIAL DISTRICT ) The foregoin Instrument was acknowledged before me this Z6-day of ��� 20&(, by �,t�uiGCLL r KOT.�ABLIC FOR ALASKA My fission expires: _�= 7 Z - Z o3 v MUNICIP ,ITI': By (signature) 1 \D L,/-v 515,0 (print name) "Oft -al sear Notary Putwfc Alyssa Porcelll State of Alaska Canmss on r1E09TY0op Exam 0YtJR470 Date: 2 Z 6 Title: Gt vit_ (rev. 05/18/2018) Page 3 of 3