• • 1 t t Municipality of Anchorage On -Site Water and Wastewater Section • (907) 343-7904 Page 1 of 3 ON -SITE WASTEWATER INSPECTION REPORT Permit Number: OSP231130 PID Number: 050-762-23 Dwelling: 0 Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: 9 New ❑ Upgrade Name Richard &Lea Johnson ABSORPTION FIELD ❑Deep Trench 9 Wide Trench [:1 Bed El Mound Site Address 19046 SilverWood Drive ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade (907) 694-4955 Five (5) 5.0 GPD/SF 0.0 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade +0.5 Ft. Gravel depth beneath pipe 0.5 Ft. Subdivision Block Lot Silverwoodhill Estates #2 1 DA Fill added above original grade 3.2 Ft. Gravel length 30.0 Ft. Township Range Section Gravel width 5.0 Ft. Beds: Number of Lines N/A Distance between lines N/A Ft. SEPARATION DISTANCES To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches 1 Dist. between trenches N/A From Tank Field Tank Line 150 Ft2 Ft. Well >50' >50' N/A N/A >25 TANK ❑ Septic ❑ S.T.E.P. ❑ Holding 91 Other Manufacturer Anchorage Tank/Orenco Capacity 2,500 Gal. Surface Water >50' >50' N/A NIA Material Steel Number of compartments 2 Lot Line >5' >10' N/A N/A NA Foundation > 1 0' > 1 0' N/A N/A LIFT STATION Manufacturer O ren co Capacity 250 Gal. Remarks Alarm location Electrical installed by Between A&B Solid Ground Electric PIPE MATERIAL House to tank D3034 Tank to drainfield D3034 Installer Northern Excavation Drainfield D3034 CO/MTD3034 Inspector M. Jakubisin BENCH MARK (Assumed elevation) 100 ft Inspection 1st 9/1/23 d 9/6/23 Location and description ection 2 Lower sliding door threshold 31d 4th ON -SITE WATER AND WASTEWATER SECTION APPROVAL Engineer's Stamp Conditional Approval: Date A,,��.. • ' ' Benjamin Septic System chiller �sr C9/11 Approved Date C I w 2 5 • . 242 Note: this approval does not include well permit requirements. ©pRQFESSI4�� �'.��,�� (Rev 05/02/18) ALTERNATE SITE Benjamin Schiller CE 12592R E GISTEREDPROFE S S I O N A L E N GINEER 1"=50' 30' LONG x 5' WIDE, 0.5' EFFECTIVE DEPTH WITH 1.5' SAND FILTER ABSORPTION TRENCH CO - CLEANOUT 2CO - DOUBLE CLEANOUT FCO - FOUNDATION CLEANOUT PV - PUMP VAULT MH - MANHOLE MT - MONITORING TUBE SV - SEPTIC VENT TH - TEST HOLE LEGEND MT1 TH#2 PERMIT # OSP231130 PID # 050-762-23 SILVERWOODHILL #2, LOT 1DA A B FCO 19.3 MH1 18.8 POD1 15.9 A B C C POD2 13.4 MH2 13.5 PV 14.5 MT1 32.8 52.6 7.0 15.7 16.3 18.9 21.4 25.5 FEET 0 50 100 S I L V E R W O O D H I L L D R I V E 5-BDRM HOME PLAN AS-BUILT 3/4/24 1400 1410 1420 1430 1440 1450 1460 30' GAS EASEMENT 60' PRIVATE ACCESS EASEMENT 20' T&E EASEMENT 30' T&E EASEMENT 10' DRAINAGE EASEMENT 5' DRAINAGE EASEMENT NEW WELL W/ 50' RADIUS TH#1 2500-GAL SEPTIC TANK WITH 2 AX-20 PODS MH2 MT2 PUMP VAULT MT2 59.0 57.2 FCO MH1 POD1 POD2 PV TH#3 BM PROFILE AS-BUILT (NO SCALE) 93.9 98.5 AX-20 POD AND MANHOLES 99.4 FINISH GRADE 30' DRAINFIELD ROCK TH # 3 GROUNDWATER 93.1' ON 8/22/23 (TH#1) 91.2' ON 9/11/23 (TH#3) 96.7 88.7 97.2 96.2 ORIGINAL GRADE Benjamin Schiller CE 12592 R E GISTEREDPROFES S I O N A L E N GINEER 3/4/24 PERMIT # OSP231130 PID # 050-762-23 SILVERWOODHILL #2, LOT 1DA 2500 GAL SEPTIC TANK PUMP VAULT MOA-APPROVED SAND MT MT 89.4 94.7 96.2 AX-20 POD AND MANHOLES FC O MH MH 2" FOAM INSULATION 96.2 94.8 95.2 2" FOAM INSULATION LESS THAN 3:1 SIDE SLOPES LEGAL DESCRIPTION: PERFORMED FOR: DATE:PARCEL ID#: SOILS LOG AND PERCOLATION TEST 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 DEPTH (feet) TEST HOLE 3 DATE READING START TIME NET TIME(minutes) DEPTH toWATER NET DROP PERCOLATION RATE: (MIN/INCH) (inches)(inches) DATE OF MONITORING WAS WATER ENCOUNTERED? DEPTH TO WATER AFTER MONITORING IF YES @ WHAT DEPTH? 1.8 8/30/23 1 2 3 Professional Engineers Stamp: YES SILVERWOODHILL #2 LOT 1DA 8/30/23 050-762-23 MICHAEL QUINN 3:30 1 0 16 1' OB 30 Benjamin Schiller CE 12592 R E GISTEREDPROFE S S I O N A L E N GINEER PERC TEST TECHNICIAN:M. JAKUBISIN 7 0 16 7.5 5.0 9/11/23 COMMENTS: SITE PLAN 6 0/16< USCS SOIL CLASSIFICATION WAS VISUALLY DETERMINED 9/19/24 GM (SILTY GRAVEL MIX) BOH TH#3 4 5 6 1 0 169:32 7 0 16 6 0/16 1 0 1610:00 6 15 16 5 15/16 1 0 16 6 12 16 5 12/16 1 0 16 6 10 16 5 10/16 1 0 16 6 9 16 5 9/16 10:00 10:00 10:00 LEGAL DESCRIPTION: PERFORMED FOR: DATE:PARCEL ID#: SOILS LOG AND PERCOLATION TEST 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 DEPTH (feet) TEST HOLE 1 DATE READING START TIME NET TIME(minutes) DEPTH toWATER NET DROP PERCOLATION RATE: (MIN/INCH) (inches)(inches) DATE OF MONITORING WAS WATER ENCOUNTERED? DEPTH TO WATER AFTER MONITORING IF YES @ WHAT DEPTH? 3.47 5/25/23 1 2 3 4 5 6 GM (SILTY SANDY GRAVEL) Professional Engineers Stamp: YES SILVERWOODHILL #2 L 1DA 5/18/23 050-762-23 SKYLER QUINN 11:11 60 16 11:38 11:50 12:01 12:12 12:23 1.5' OB 30 Benjamin Schiller CE 12592 R E GISTEREDPROFE S S I O N A L E N GINEER PERC TEST LOCATION TECHNICIAN:L.TIDWELL 120 16 3.5 5.1 8/22/23 COMMENTS: SITE PLAN 60 16 USCS SOIL CLASSIFICATION WAS VISUALLY DETERMINED 8/30/23 60 1610 94 16 34 16 60 1610 90 16 30 16 60 1610 814 16 214 16 60 1610 813 16 213 16 60 1610 813 16 213 16 60 1610 814 16 214 16612:34 TH#1 UTE E E R I N G October 11, 2024 PO BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 (FAX) FORGECIVIL.COM MOA Development Services, On -Site Water & Wastewater Program 4700 Elmore Rd Anchorage, AK 99507 Subject: Silverwood Hill Est #2 LIDA —19046 Silverwood Hill Dr Waiver Requests, tank to deck post Dear On -Site Services Engineer: The design for the septic system on this lot showed the new tank set further from the house and deck to achieve 10' separation to the foundation and 5' separation to the corner deck support. However, adjustments to the home location after the septic was installed meant that one deck support ended up closer than 5' to the septic tank. The deck is supported on helical piles driven into the ground to refusal. The piles were driven to a minimum of 10' deep. The bottom of the tank is at 9.l' below grade. At those depths, the tip of the piles (being the primary source of strength) would not bear at all on the septic tank. In addition, the orientation of the tank causes the encroachment primarily on the corner, and not the side of the tank. We do not anticipate any negative effects from the encroachment. For this reason we are requesting a waiver for a 3.9' separation from the tank to the deck post. This approval will not have any negative consequences on the home or property. Sincerely, Benjamin Schiller, PE E ,_ E x C_ f..o Ti ar- oF- / WELL FLOW TEST REPORT Conducted by Anchorage Well & Pump Service 7640 King Street, Anchorage AK 99518 Ph: (907) 243-0740 Fax: (907) 243-0742 OWNER INFORMATION PUMP INFORMATION Owner:Intake Depth: Static Water Level: Address:Depth of Casing Max Drawdown: PUMP ON Time:3:30pm Date:10/05/23 Well Production:3.78 GPM PUMP OFF Time:10:42am Date:10/06/23 (at time of test) Flowmeter Gallons Comments Reading Pumped 10/5/23 3:30pm 33649 Start pump 10/6/23 10:00am 37809 Check flow meter - well dry 10/6/23 10:10am 37809 Start pump 10/6/23 10:14am 37861 3.71 Pump off 10/6/23 10/24am 37861 Start pump 10/6/23 10:28am 37876 3.78 Pump off 10/6/23 10:38am 37846 Pump start 10/6/23 10:42am 37891 3.78 End test Final flow at time of test 3.78 GPM Besser William Stewart & 19036 Silverwood Hill Dr Eagle River, A 99577 Martha Frances Water LevelElapsed Time Feet * Well chlorinated and flushed prior to test. Test performed at wellhead Certified Drilling Log OWNER OF LAND: Michael Quinn Construction ADDRESS: LEGAL DESCRIPTION Silverwood Hill Estates #2 Lot 1DA DATE: 9-29-23 PERMIT NUMBER: OSP231130 DATE OF ISSUE: 6-9-23 TAX IDENTIFICATION NUMBER 05076223000 Is well located at approved permit location: Yes No Method of Drilling: air rotary cable tool Depth of Well: 400’ Casing Type: Steel Wall thickness .250 inches Diameter: 6 inches, depth 44 feet Liner type Static Water Level: 20 feet Recovery Rate 3.2 gpm gph Method of Testing Air Well Intake Opening Type: open end open hole Screened Start feet Stopped Perforations Start feet Stopped Grout Type: Bentonite Volume: 6 bags Depth: from 2 feet, to 42 feet Well Disinfected Upon Completion: yes no Method of Disinfection: Chlorine 50 PPM Comments: Well yield after hydro-frac. Shallow Bedrock surface seal installed per MOA Code Bore Hole Data Depth From To 0 2 Casing Stickup 2 41 Bedrock Fractured 41 60 Bedrock Gray 60 160 Bedrock Gray w/ Quartz 160 180 Bedrock Gray 180 240 Bedrock Gray Dark 240 400 Bedrock Gray w/ Quartz Seams Drillers Name: Cole Sullivan ATTENTION: It is the responsibility of the property owner to submit a copy of the well log to the proper authority. Municipality of Anchorage: Department of Health & Human Services and/or Department of Environmental Conservation. MatSu Borough: Department of Environmental Conservation. Pump Installation Log Arctic Pump & Well Inc . Jim Sullivan PO Box 770197 Eagle River, AK 99577 (907) 688 -2510 (907) 243 -2282 jim@arcticpump.com OSP231130 05076223000 6/9/2023 Silverwood Hill Est #2 L1DA 1DA Quinn Construction PO BX 772641 Eagle River AK 99577 8/7/2024 389 Feet Franklin 10PMQP-1.5HP-3RC 1.5 HP 9 Feet ss Well Drilling Permit Number: Parcel Identification Number: Date Of Issue: Legal Description Lot: Block: Property Owner Name Address: Pump Installaion Date: Pump Intake Depth Below Top of Well Casing: Pump Manufacturer's Name Pump Model: Pump Size: Pitless Adapter Burial Depth: Pitless Adapter Manufacturer's Name Pitless Adapter Installer: Well Disinfected Upon Completion? Method of Disinfection: u/k Yes Chlorine Comments: Pump Installer Name: Arctic Pump & Well, Inc. 5Y Wednesday, August 7, 2024 MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Water & Wastewater System Permit Permit Number: OSP231130 Effective Date: Work Type: WellSeptic Initial Expiration Date: Tax Code Number: 05076223000 Site Legal Address: SILVERWOODHILL ESTATE #2 LT 1 D G:0354 Site Mailing Address: Owner: JOHNSON RICHARD BAARD & LEA S Lot Size in Sq Ft: Design Engineer: FORGE ENGINEERING Total Bedrooms: This permit is for the construction of: 6/9/2023 6/8/2024 245930 Q Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy Q Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Received B y; Date: I Issued By:Date: 6/20 Z 5 Community Development Department f h. Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On -Site Water & Wastewater Program ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 050-762-23 Property owner(s) Richard & Lea Johnson Day phone (907) 694-4955 Mailing address 120B Washington Road, West Point, NY 10996 Site address Silverwood Hill Drive Legal description (Sub'd., Block & Lot) Silverwoodhill Estates #2 Lot 1 DA Legal description (Township, Range & Section) Lot Size 245,930 Sq. Ft. Number of Bedrooms 5 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (® all that apply) Absorption Field ❑X Initial ❑X Single Family (SF) ❑X AD U) Septic Tank 19Upgrade El(w/wo (D) ❑ Holding Tank ❑ RenewalDuplex ❑ Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑X Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. �Y L (Signature of property owner or authorized agent) Permit/Rush Fees: Ab'i�>Z//D Waiver Fees: Date of Payment: to r ?a23 Date of Payment: Receipt Number: 3 2 ` Q Receipt Number: Permit No. DC2 P 23 11 30 Waiver No. Permit App_'-'-:- :'-:c; June 8, 2023 MOA Development Services, On-Site Water & Wastewater Program 4700 Elmore Rd Anchorage, AK 99507 Subject: Silverwoodhill Estates #2 Lot 1DA - NHN Silverwood Hill Drive Septic system design Dear On-Site Services Engineer: The owner of the above lot intends to build a 5-bedroom home on the property, so we are submitting this permit application for the construction of a new well and septic system. The attached site plan identifies the location of the home as well as the proposed well, septic location and alternate site. The ground surface on the lot slopes moderately down from the road at grades between 17-23%. There are no slopes greater than 25% within 50 feet downslope of either the primary or alternate site. Contours are shown on the site plan showing the grade and direction of flow. Stormwater drainage will not impact this septic system. The new trench will be constructed parallel to the slope as much as possible. The test holes dug on the lot perked at rates between 3-8 min/in. We have chosen to use the slower perk rate to be conservative, although we are building the trench around the test hole with the faster percolation. Wells on this and adjacent lots are shown. The new system will be a minimum of 100’ from all wells and surface water, and more than 5’ away from the septic tank. The alternate site is located more than 6’ away. Please refer to the attached test hole logs, plan and profile pages for the septic design. If this design is followed, there will be no adverse impacts to adjacent properties. Sincerely, Benjamin Schiller, PE Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP231130, Curtis Townsend, 06/09/23 ALTERNATE SITE Benjamin Schiller CE 12592REGISTEREDPROFESSION A L E N GINEER 1"=50' 30' LONG x 5' WIDE, 0.5' EFFECTIVE DEPTH WITH 1.5' SAND FILTER ABSORPTION TRENCH 1500-GAL SEPTIC TANK w/ BAFFLE REMOVED CO - CLEANOUT 2CO - DOUBLE CLEANOUT FCO - FOUNDATION CLEANOUT PV - PUMP VAULT MH - MANHOLE MT - MONITORING TUBE SV - SEPTIC VENT TH - TEST HOLE LEGEND MT TH#2 SILVERWOODHILL #2, LOT 1DA FEET 0 50 100 S I L V E R W O O D H I L L D R I V E 5-BDRM HOME SEPTIC PLAN 5/30/23 1400 1410 1420 1430 1440 1450 1460 1470 1480 30' GAS EASEMENT 60' PRIVATE ACCESS EASEMENT 20' T&E EASEMENT 30' T&E EASEMENT 10' DRAINAGE EASEMENT 5' DRAINAGE EASEMENT PROPOSED WELL LOCATION W/ 50' RADIUS TH#1 1000-GAL RECIRCULATING TANK WITH 2 AX-20 PODS FCO MT PUMP VAULT Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP231130, Curtis Townsend, 06/09/23 SILVERWOODHILL #2, LOT 1DA TYPICAL TRENCH SECTION (NO SCALE) NOTES: 1. GRADE AREA OVER TRENCH TO DRAIN AWAY 2. PROVIDE 3' OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2' WITH 2" OF INSULATION 3. CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY Benjamin Schiller CE 12592REGISTEREDPROFESSION A L E N GINEER DRAINFIELD ROCK 5' 1'-6" DESIGN FACTORS:SYSTEM REQUIREMENTS: 750 GPD PEAK FLOW PERK RATE: 7 MIN/IN APPLICATION RATE: 5 GPD/SF 5' WIDE TRENCH SYSTEM CAT III ADVANCED TREATMENT SYSTEM: 1500-GAL SEPTIC TANK + 1000 GAL RECIRCULATION TANK AND PUMP VAULT BOTTOM OF TRENCH: AT GRADE FLOW LINE ELEVATION: 0.5' ABOVE GRADE 750 GPD / 5 GPD/SF / 5' WIDE *1 RED FACTOR [0.5 DEEP] = 30 LF TRENCH REQUIRED (30 LF SPECIFIED) GEOTEXTILE FABRIC 1.25" PVC w/ 20 x 3 8" ORIFICES EVENLY SPACED @ 1.5' OC (HOLES DOWN) 5/30/23 6" MOA APPROVED SAND FILTER 2" INSULATION 3:1 MAX SIDE SLOPES2' PROVIDE ADDITIONAL FILL TO ENSURE 2' MIN COVER AFTER SETTLEMENT Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP231130, Curtis Townsend, 06/09/23 LEGAL DESCRIPTION: PERFORMED FOR: DATE: PARCEL ID#: SOILS LOG AND PERCOLATION TEST 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 DEPTH (feet) TEST HOLE 1 DATE READING START TIME NET TIME (minutes) DEPTH to WATER NET DROP PERCOLATION RATE: (MIN/INCH) (inches)(inches) DATE OF MONITORING WAS WATER ENCOUNTERED? DEPTH TO WATER AFTER MONITORING IF YES @ WHAT DEPTH? 3.47 5/25/23 1 2 3 4 5 6 GM (SILTY SANDY GRAVEL) Professional Engineers Stamp: YES SILVERWOODHILL #2 L 1DA 5/18/23 050-762-23 SKYLER QUINN 11:11 6 0 16 11:38 11:50 12:01 12:12 12:23 1.5' OB 30 Benjamin Schiller CE 12592REGISTEREDPROFESSION A L E N GINEER PERC TEST LOCATION TECHNICIAN: L.TIDWELL 12 0 16 3.5 2.9 5/25/23 COMMENTS: SITE PLAN 6 0 16 USCS SOIL CLASSIFICATION WAS VISUALLY DETERMINED 5/25/23 6 0 1610 94 16 34 16 6 0 1610 90 16 30 16 6 0 1610 814 16 214 16 6 0 1610 813 16 213 16 6 0 1610 813 16 213 16 6 0 1610 814 16 214 166 12:34 TH#1 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP231130, Curtis Townsend, 06/09/23 LEGAL DESCRIPTION: PERFORMED FOR: DATE: PARCEL ID#: SOILS LOG AND PERCOLATION TEST 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 DEPTH (feet) TEST HOLE 2 DATE READING START TIME NET TIME (minutes) DEPTH to WATER NET DROP PERCOLATION RATE: (MIN/INCH) (inches)(inches) DATE OF MONITORING WAS WATER ENCOUNTERED? DEPTH TO WATER AFTER MONITORING IF YES @ WHAT DEPTH? 7.6 5/25/23 1 2 3 GM (SILTY SANDY GRAVEL) Professional Engineers Stamp: YES SILVERWOODHILL #2 L 1DA 5/18/23 050-762-23 SKYLER QUINN 11:11 6 0 16 12:14 12:48 1.5' OB 30 Benjamin Schiller CE 12592REGISTEREDPROFESSION A L E N GINEER PERC TEST LOCATION TECHNICIAN: L.TIDWELL 10416 2.5 2.0 5/25/23 COMMENTS: SITE PLAN 410 16 USCS SOIL CLASSIFICATION WAS VISUALLY DETERMINED 5/25/23 6 0 1630 91416 31416 6 0 1630 9 15 16 3 15 16 TH#2 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP231130, Curtis Townsend, 06/09/23 Parcel I.D. 050-762-23 Certificate of On -Site Systems Approval Expiration Date: Legal description SILVERWOODHILL ESTATE #2 LT 1 DA Site address 19046 SILVERWOOD HILL DR Eagle River Current property owner(s) MICHAEL QUINN CONSTRUCTION X The On -site system(s) is/are approved for 5 bedrooms Conditional approval for Comments or advisories: c 9/4/2025 bedrooms, with the following stipulations: Original Certificate Date: 10/16/2024 This Certificate of On -Site Systems Approval (COSA) is intended to demonstrate the subject system(s) is/are in substantial compliance with municipal code. The Municipality of Anchorage, Development Services Department (DSD) issues COSAs based upon representations provided by an independent professional engineer. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. ATTACHMENTS: COSA Checklist X Well Flow Advisory Absorption Field Advisory Nitrate Advisory Tank Age Advisory Arsenic Advisory Other COSA Approval_June 2022 MUNICIPALITY OF ANCHORAGERU.514 1 51A 81, 51A 51A, 51A, Development Services Department Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Certificate of On -Site Systems Approval Application 1. GENERAL INFORMATION Parcel I.D. 050-762-23 Complete legal description Silverwood Hill Est #2 Lot 1 DA Location (site address) 19046 Silverwood Hill Dr, Eagle River, AK 99577 Current property owner(s) Richard & Lea Johnson 2. ON -SITE SYSTEMS SIZED FOR BEDROOMS Day phone 3. TYPE OF WATER SUPPLY: Fm� Private Well R Private Well serving 2 dwelling units El Private Well serving 3+ dwelling units Fj Community Well or Public D Water Storage 4. TYPE OF WASTEWATER DISPOSAL: Fm� Private Septic E] Private Septic serving 2 dwelling units Fj Holding Tank D Community Septic or Public Sewer 5. SEPTIC TANK: RE Steel R Plastic R Concrete R Fiberglass Age NEW _ See advisory if steel older than 20 years 6. ABSORPTION FIELD: rk AWWTS Fj Bed R Deep Trench OR Wide Trench R Seepage Pit Waiver request for: Expedited review requested: nN Distance: By applying for this entitlement, this property is subject to inspection by municipal On -site staff to verify the accuracy of the information provided. COSAFee $ 1/1-0 Waiver Fee $ Date of Payment COSA #.. 0_5 C 2 �I Date of Payment Waiver # COSA Application —June 2022 1.05 6.48 Forge Engineering N/A N/A N/A Benjamin Schiller, P.E. (907) 522-7773 Lot 1DA Silverwood Hill Estate Subdivision No. 2 As-BuiltS4 Group Land Surveying Land Development Consultants Subdivision Specialists Construction Surveying AEC# 173042 124 E 7th Avenue Anchorage, Alaska 99501 (907) 306-8104 mail@S4AK.com 9/26/2024 MUNICIPALITY OF ANCHORAGE ADVANCED `NIASTENVATER TREATMENT SYSTEM MAINTENANCE AND REPAIR AGREEMENT THIS MAINTENANCE AND REPAIR AGREEMENT, herein the "AGREEMENT" made and entered into as of this 3O Day of i �e-r of 202-4 , by and between 12; ��o., oh.,� �„r► , herein the "OWNER," and the Municipality of Anchorage. herein the "MUNICIPALITY", in accordance with Anchorage Municipal Code (AMC) 15.65.365, In consideration of the mutual covenants contained herein, the parties to this Agreement agree as follows: 1. Advanced Wastewater Treatment Systems. The Municipality grants permission to the Owner to utilize and operate an Advanced Wastewater Treatment System (AWVVTS), described as CAT III Advanced Treatment System located at (legal description) `)'Aq e,,Doa IA" kk E s -ate A Z. L,. = I b A 2. Maintenance. Repairs and Alterations. (Owner is required to read, understand and initial each section) � Throughout the term of this Agreement, the Owner shall enter into a service agreement with an AWWTS service and maintenance provider approved by the Municipality or the manufacturer's representative. The AWWTS shall be maintained in a satisfactory condition capable of performing as designed and producing treated septic effluent in accordance with the equipment's approval for operation ur the Municipality. L_ It shall be the responsibility of the Owner during the tenn of this Agreement to pay for all repair(s), maintenance, adjustment(s), replacement costs, and inspection costs. This includes an annual maintenance fee (typically $400 to $600). 46_j Owner agrees that only maintenance and repair personnel approved by the Municipality or the manufacturer's representative will inspect and make any necessary maintenance, repairs or permitted alterations to the system. 24,y— Owner acknowledges that regular maintenance of an AWWTS reduces the potential failure of the system, which could uiclude sewage backup and costly repairs or drauifield replacement. (rev. 05/18/2018) Page 1 of 3 Owner acknowledges that the Municipalitvinay request records of maintenance and repairs from the manufacturer's representative or Maintenance provider. � Z-- zn O\vner acknov,,4ledges that the fine for falling to maintain and repair an AWWTS may be assessed in accordance with A -MC 14.60.030, Owner agrees to grant the Municipality reasonable access to test and inspect the AWWTS. The Municipality will give at least 24-hour notice. Z�� Owner agrees that any sale or transfer of title of the property will not occur -ivithout a new Certificate or'On-Site Systems Approval. Owner agrees that the AWWTS installation and maintenance requirements as provided by the AW�VTS vendor/installer and approved by the Municipality are the governing guidelines for the construction-, maintenance and repair of the Owner's ANV-WTS. O'%vner agrees to maintain remote monitoring of the AWWTS as required by the AIAMITS approval. 3. Term. The term of this Agreement shall begin oil the date of approval by the Municipality to operate the installed system., or upon transfer of title, and shall continue while the AWWTS is operational or until title is transferred. 4. Non waiver. The failure of the Municipality at any time to enforce a provision of this Agreement shall in no way constitute a waiver of the provisions, nor in any way affect I I the validity of the Agreement or any part hereof, or the right of the Municipality thereafter to enforce every prwv ision hereof 5, Amendment. This Agreement shall only be amended by authorized representatives of the Owner and Municipality. Any attempt to amend this agreement by either an unauthorized representative or unauthorized means shall be void. 6. Jurisdiction: Choice of Law. Any civil action arising from this Agreement shall be brought in the Superior Court for the Third Judicial District of the State of Alaska at a Anchorage. The laws of the State of Alaska shall govern the rights and obligations of the zn �7 - 1 parties under this Agreement. 7, Severability. Any provisions of this Agreement decreed invalid by a court of competent jurisdiction shall not invalidate the remaining provisions of the Agreement. (rev. 05/18/2018) Page 2 of 3 ONAINER: By.-_ - -"(signature) Date: -2" �---4- SVx vt5oi (print name) STATE OF ALASKA SS. THIRD JUDICIAL DISTRICT The forepiqgg instrument ,as acknowledged before me tllisD day of by KJC�ar6 Sj)k A NOTARYPUBLIC ORALASKA My Commission expires: AIUNICIEPALITY- By: ,------,-.-(signature) (print name) Date: 0 2- 27 Titte: L- C- E_ r2- (rev. 05/18/2018) Page 3 of 3