HomeMy WebLinkAboutBLUE BEARYESTATES LT 1Blue Beary
� t t
MUNICIPALITY OF ANCHORAGE I-vc„r s
On -Site Water & Wastewater Program No
PO Box 196650 4700 Elmore Road i
Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997
http://www.muni.org/onsite y..,
i
Department
On -Site Water & Wastewater System Permit
Permit Number: OSP221367 Effective Date: 6/14/2023
Work Type: WellSeptic Initial Expiration Date: 6/13/2024
Tax Code Number: 02002132000
Site Legal Address: BLUE BEARYESTATES LT 1 G:3242
Site Mailing Address: 9500 HONEY BEAR LN, Anchorage
Owner: FARNHAM MICHAEL & ASHLEY Lot Size in Sq Ft: 328282
Design Engineer: ANDERSON CONSTRUCTION & ENGINEERING Total Bedrooms: 4
This permit is for the construction of:
Q Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy Q Private Well ❑ Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
Special Provisions:
A test hole is required prior to construction of the absorption field, in the location shown on the site plan, to
confirm minimum separation to impermeable soil and seasonal high groundwater, as well as percolation rate.
Construction may proceed at your own risk prior to 7 -day groundwater monitoring. If results require a design
change, construction shall stop pending approval of a change order. Please submit results with the inspection
report (or change order, if required).
Received By: I S ,,\A Date:
Issued By: Date: Z 3
MUNICIPALITY OF ANCHORAGE
Development Services Department -343-7904
On -Site Water & Wastewater Section --- Fax: 907-343-7997
ON-SITE SEPTIC/WELL PERMIT APPLICATION
Parcel I.D. 020-021-32
Property owner(s) FARNHAM
Mailing address 5777 SERENITY LANE, ANCH AK
Site address
Day phone
Legal description (Sub'd., Block & Lot) BLUE BEARY ESTATES LT 1
Legal description (Township, Range & Section)
Lot Size 328282 Sq. Ft. Number of Bedrooms 4
APPLICATION IS FOR:
APPLICATION IS AN:
TYPE OF DWELLING:
(® all that apply)
Absorption Field
Fx�
Initial El
Single Family (SF) El
ADU)
Septic Tank
El
Upgrade El(w/wo
Duplex (D) ElHolding
Tank
ElRenewal
ElMultiple
Dwellings ❑
Privy
❑
(SF and/or D)
Private Well
Water Storage
❑
THIS APPLICATION
INCLUDES A WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit/ ush Fees: SIS �"� ��Za-Waiver Fees:
ate of Payment: q%12�2 Z Date of Payment:
Receipt Number: �la'l2-�l Receipt Number:
Permit No. ( a7DeX13(Pl Waiver No.
GADevelopment Services\Building Safety\On Site Water and Wastewater\Forms\Client FormsTermit Application.doc
May 25, 2023
Municipalities of Anchorage
On-Site Water and Waste Water Section
4700 Elmore Rd
Anchorage, Alaska
Phone 343-7904
Re: New septic & well permit
Legal: BLUE BEARY ESTATES LT 1
To whom it may concern:
This is a request for a septic and well permit on the above referenced lot. A single
test was done on this lot by Pannone Engineering Services LLC for the new Blue
Berry Subdivision, see MOA file S-12325. The total depth was 14 feet and the perc
was 1 minutes per inch. A deep trench has been designed for the site. The steep 40
percent slope will require additional fill be placed down slope of the proposed field,
see the site plan. This new septic system will not impact any of the neighbors or
encroach on any wells, septic or open water issues.
Sincerely
Michael N. Anderson, P.E.
4661 Natrona
Anch, Ak 99516
Ph 727-8864
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP221367, Curtis Townsend, 06/14/23
SEPTIC FIELD SECTION
DESIGN CRITERIA:
4.0' EFFECTIVE
4 BDRM X 150 = 600 GPD
SOILS = 600/1.2 = 500 GPD
500 GA/8 = 63'
2.0' WIDE
63' LONG
(1) TRENCH
8' DEEP
14
(TH#1 BY PES LLC)
1.0
GM/SM
ORG
2.0'
-4.0
FILTER FABRIC
SEWER ROCK
3,3(
GRADE
1"=200'
PROPERTY LINEPROPOSED
DRAINAGE FIELD
PROPOSED HOUSE
PROPOSED WELL
100' RADIUS
DRY OCT 2016, SEE S-12325
& INSULATION
SCALE:
DJRDRAWN:
DATE:
BLUE BEARY ESTATES LT 1
Anchorage, Alaska
ASHLEY FARNHAM
3/16/2023
-8.0
FILL AREA, MAX
25% SLOPE
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP221367, Curtis Townsend, 06/14/23
NEW 1250 GALLON
PLASTIC STEP TANK,
w/ 20" RISERS
1"=50'
PROPERTY LINE
PROPOSED
HOUSE
PROPOSED WELL
100' RADIUS
EXISTING 40 %
SLOPE MUST BE
FILLED FOR A MAX
SLOPE OF 25% 50'
FROM THE FIELD
TYP.WELL
WELL
MT
FCO
DCO
TH#1
SCALE:
DJRDRAWN:
DATE:
BLUE BEARY ESTATES LT 1
Anchorage, Alaska
ASHLEY FARNHAM
3/16/2023
CO
NEW TEST HOLE
REQUIRED PRIOR
TO EXCAVATION
1
S3
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP221367, Curtis Townsend, 06/14/23
1"=20'
4:1 SLOPE 2.5'
ABOVE PIPE
INVERT
EXISTING 40 %
SLOPE MUST BE
FILLED FOR A MAX
SLOPE OF 25% 40'
FROM THE FIELD
TYP.
ADDITIONAL FILL
PLACED FROM THE
FOUNDATION
EXCAVATION
SCALE:
DJRDRAWN:
DATE:
BLUE BEARY ESTATES LT 1
Anchorage, Alaska
ASHLEY FARNHAM
3/16/2023
30.0'
4.
0
'
2.
5
'
DRAFTING LINE
ONLY
15.0'
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP221367, Curtis Townsend, 06/14/23
123
MICHAEL J. HORNE
LS-5318
PLOT-PLAN OF:
SCALE:
GRID No:
WORK ORDER No.
DRAWN:CHECKED:
DATE:
FB BOOK/PAGE:
APR 11, 2022 80'
MECB SW3242 N/A
Lot 1, Blue Beary Estates Subdivision,
Anchorage, Alaska
Plat No. 2018-22
SERVI N G A L A SKA SI
N
C
E
1
9
8
2
EXCLUSION NOTES: It is the owners responsibility to determine
the existence of any easements, covenants, or restrictions which
do not appear on the Plat used for this survey. NOTE: Under no
circumstances should any data hereon be used for construction
or for the establishing of property lines.
Monument
Septic Vent
Power pole
PREPARED FOR:
Ashley FarnhamZONING:
R-10SL
SURVEY CERTIFICATION: FARPOINT has not
conducted a physical survey of the subject property,
the improvements situated thereon are within the
property lines as shown.
1.Bearings and distances are record per referenced plat unless otherwise noted.
2.It is the responsibility of the person staking the location of the house to verify that the house location
does not encroach adjoining parcels, Rights-of Way, or MOA setback requirements.
3.Elevations and contours shown hereon taken from MOA LiDAR on the adjusted 1972 datum.
4.Spot Elevations interperlated from MOA LiDAR topo, no field survey conducted.
123 Address Marker
Drainage Arrow
Spot Elevation744'