HomeMy WebLinkAboutEQUESTRIAN HEIGHTS BLK 2 LT 18AA
HEIGHTS
a�
Municipality of Anchorage
On-Site Water and Wastewater Section • (907) 343-7904 Page 1 of 2
ON-SITE WASTEWATER INSPECTION REPORT
Permit Number: OSP231163
PID Number: 017-092-90
Dwelling: ❑■ Single Family (SF)
❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: X New ❑ Upgrade
Name
Hultquist Homes, Inc.
ABSORPTION FIELD
❑ Deep Trench 0 Wide Trench ❑ Bed ❑ Mound
Site Address
14225 Picket Street
❑ Other
Phone
Number of Bedrooms
Soil RatingTotal
depth from original grade
5
�•8 GPD/SF
6.0 Ft.
LEGAL DESCRIPTION
Depth to pipe invert from original grade
2.0 Ft.
Gravel depth beneath pipe
4.0 Ft.
Subdivision
Block Lot
Equestrian Heights
2 18A
Fill added above original grade
0.7 Ft.
Gravel length
2@47 Ft.
Township Range Section
Gravel width
5.0 Ft
Beds: Number of Lines
n/a
Distance between lines
n/a Ft.
SEPARATION
DISTANCES
To
Septic
Absorption
Lift Station
Holding
Sewer
Total absorption area
Number of trenches
Dist. between trenches
From
Tank
Field
Tank
Line
940 Ft2
2
8.0 Ft.
Well
100'+
100'+
100'+
NA
25'+
TANK ❑ Septic X S.T.E.P. ❑ Holding ❑ Other
Manufacturer
Anchorage Tank
Capacity
2500 Gal.
Surface Water
100'+
100'+
100'+
NA
Material
Number of compartments
Lot Line
10'+
101+
10'+
NA
NA
Steel
2
Foundation
10'+
10'+
10'+
NA
LIFT STATION
Manufacturer
Capacity
Remarks Field installed w/2.0" insulation
Orenco
250 Gal.
Alarm location
Inside Attached Garage
Electrical installed by
Dependable Services
Installer
PIPE MATERIAL House to tank 3034 Tank to ASTM D1785
drainfield
Hultquist Homes, Inc.
Drainfield ASTM D1785 Co/MT3034
Inspector PES
BENCH MARK (Assumed elevation) 100.0 ft
Inspect tiosn v 06/22/23
06/23/23
Location and description
2nd
31d 06/26/23
40' 03/08/24
See Site Plan, Bottom Trim House corner
ON-SITE WATER AND WASTEWATER SECTION APPROVAL
Engineer's Stamp
Conditional Approval:
Date
P• '
... .. .......
even annope
•. CE 8149 ;
Septic Syste
Approved
Date 3
'••:024.°3.':••'
. ,AIOFB'
Note: this approve I does not include well permit requirements.
PROFILE
PA
N
N
O
N
E
E
N
G
S
V
C
,
L
L
C
(
C
.
I
.
1
0
8
8
)
As Built
Land Surveying
Land Development Consultants
Subdivision Specialists
Construction Surveying
AEC# 173042
S4
Group
124 E 7th Avenue
Anchorage, Alaska 99501
(907) 306-8104
mail@S4AK.com
Lot Lot 18A, Block 2,
Equestrian Heights Subdivision
02/22/2024
017-092-90
017-092-90
MUNICIPALITY OF ANCHORAGE relent s
On -Site Water & Wastewater Program 'o
PO Box 196650 4700 Elmore Road
Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997
http://www.muni.org/onsite J
I
1)ehaI-tIII e11t
On -Site Water & Wastewater System Permit
Permit Number: OSP231163 Effective Date: 6/16/2023
Work Type: WellSeptic Initial Expiration Date: 6/15/2024
Tax Code Number: 01709269000
Site Legal Address: EQUESTRIAN HEIGHTS BLK 2 LT 18 G:3038
Site Mailing Address: 14225 PICKETT ST, Anchorage
Owner: HULTQUIST HOMES INC Lot Size in Sq Ft: 22577
Design Engineer: PANNONE ENGINEERING SERVICES Total Bedrooms: 5
This permit is for the construction of:
Q Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy Q Private Well ❑ Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
Special Provisions: 7 day groundwater monitoring was not completed in test hole 2 in the area of the proposed
trench. Verify groundwater in this prior to proceeding with installation of the field. If results require a design
change, construction shall stop pending approval of a change order. Please submit results with the inspection
report (or change order, if required).
Received By: >SV�J��S Date:
20
Issued By: Date: b Z 3
MUNICIPALITY ALITY OF ANCHORAGE R vs H
Community Development Department `° = c Phone: 907-343-7904
Development Services Division Fax: 907-343-7997
On -Site Water & Wastewater Program
ON-SITE SEWERIWELL PERMIT APPLICATION
Parcel I.D. 017-092-69
Property owner(s) Hultquist Homes, Inc. Day phone
Mailing address
Site address 14225 Pickett Street
Legal description (Sub's., Block & Lot) Equestrian Heights Block 2 Lot 18
Legal description (Township, Range & Section)
Lot Size 22,577 Sq. Ft. Number of Bedrooms 5
APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING:
(N all that apply)
Absorption FieldX❑ Initial
I—XI Single Family (SF) X❑
Septic Tank X❑ Upgrade
❑ (w/wo AD U)
Holding Tank ❑ Renewal
Duplex (D) ❑
❑
Privy ❑
Multiple Dwellings ❑
(SF and/or D)
Private Well X❑
Water Storage ❑
THIS APPLICATION INCLUDES A VARIANCE /
WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further
certify that this is in accordance with
applicable Municipal Codes.
SRP
(Signature of property owner or authorized agent)
Permit/Rush Fees: - / 3 Z
Waiver Fees:
Date of Payment:
Date of Payment:
Receipt Number:
Receipt Number:
Permit No. 0-'5 P 2'5 1163
Waiver No.
Permit App_::- : ,_.,:c
Wricipality of Pndiorage
On-site Water and Wastewater
REVIEWED FOR CODE COtUI UMC
OSP231163, Curtis Townsend, 06116)
Steven R. Pannone, Principal
Registered Professional Engineer
E-mail: steve@paneneak.com
15 June 2023
Municipality of Anchorage
Development Services Department
On -Site Water & Wastewater Program
4700 Elmore Road
P. O. Box 196650
Anchorage, Alaska 99519
Subject: Equestrian Heights Block 2 Lot 18
Well & Septic System Permit Request
Septic System Design Narrative
This is a design narrative for a permit to install an initial septic system on the subject property. The proposed system
will serve a proposed five -bedroom (5) house. This lot and surrounding lots are served by private wells. Currently
there are no wells within 100 feet of the proposed system.
1. Soils:
Two test holes were performed on this lot by Pannone Engineering Services, LLC on (TH-105/23/2023) and
(TH-2 06/06/2023). Groundwater was not observed during the excavation of test hole (1), and bedrock was not
encountered. No groundwater was observed in this test hole monitor tube after 7 -days. Based on the overall soils
appearance and percolation test results of test hole (2); an application rate of 0.8 gpd/SF was used for the design of
a conventional wastewater treatment system in the area of test hole (2).
2. Soil Absorption System Design.
a. See Sheet 1 of the design package.
3. Surface Water:
There is no surface water within 100 feet of the proposed septic tank and drain field.
4. Topography:
See attached site plan for area topography. There are no slopes exceeding 25% within 50ft of the proposed drain
field.
Mailing: P.O.Box 1807, Palmer, AK 99645
Telephone: (907) 745-8200 FAX: (907) 745-8201
Page 2 of 2
5. Drawing Markings: The Drawings are marked "For MOA Review Only". When written notification that the
review is complete and no further comments are received from MoA On -Site Department, the note will be removed
and "For Construction" drawings will be issued.
The proposed installation will not affect the future development of this or the surrounding lots.
If you have any questions or concerns, please contact me at (907) 745-8200.
Sincerely,
�1
Steven R. Pannone, P.E. F. ASCE
Owner/Civil Engineer
Mailing: P.O.Box 1807, Palmer, AK 99645
Telephone: (907) 745-8200 FAX: (907) 745-8201
-�j c�i1 n 0-- = D
I
Q)\w
V1 Z Z7
-I
D
--I ^ C
D1'Li)t
co
CO
Ocn(n
DTrilm
[7>00mDprn
Z� yr �z' m
ONcn
Dvm
om�70OmDO�
�or--Clx;;DOmm
vyi c
r x
r O7 x
m 0->0 (nm<
cn
r .p
r O CO D
z 1113
v,
"D z
�O zC ZN �p -Vl <
D
I I
DUD
o
m
N C7 m
�m'o
G)O -..I
N
D�
X
XO
m -0 O -.. I D
0v m0ZrnJ
Z
=
CO
Dx
pOm
D cn
OX
Gp mr
U-1 O o O —41
o C r
i ��, =ayoz
JD
/
_w
m
I I
0>OClp
pm0
pWZpm
� —0
0
Z
D
O ---I co '0- �
O
ox
-�'
Oo -AN�
r CJi -I i0 Cl)
I
o
N
�lO
��
Z O
�
�
IZ���D
m��
o
m
rCf)
\
TQ
-ci
z
o
_ Cn D° a
m
rn
_ m�
a
FTI
m
u12r n OD
mO
_U
I
X
Nv Z)
U)
I I
r
C7
C7T7
0
Pq
I
r
Rl-
4-
M
OL-
PICKETF �S-TREET Z
oa—
�
PAVED D IVE (P) b
as
o� I 1
L
DO O Cprq
o , o ry J /
N3 co
a
DRAWN L,1C EQUESTRIAN HEIGHTS BLOCK 2 LOT 18
CHECKED ACP HULTQUIST HOMES, INC.
SITE: 14225 PICKETT STREET
SITE PLAN ANCHORAGE, AK 99516
1"=50'
J.D. NO
017-092-69
ERMIT NO.
05PXXXXXX
HEET
1 OF 3
Q)\w
LJ
y �
Elec E/smf
my
i ��, =ayoz
/
_w
I
w
>Aa
o�-Nm
rn
I
m
u12r n OD
mO
I
Nv Z)
-j
I I
Pq
n�r " oho
I I
—
1
m C)o ----
I
L—
I
�o
NOTES:
PANNONE ENG SVC LLC (C.I. 1088)
P.O. BOX 1807 PALfv�ER, AK 99645
REVISIONS
DATE
06/15/2023
for construction
PHONE (907) 745-8200 FAX (907) 745-8201
�OFA�,
�P.•''• �'•. -1►
crei r
DRAWN L,1C EQUESTRIAN HEIGHTS BLOCK 2 LOT 18
CHECKED ACP HULTQUIST HOMES, INC.
SITE: 14225 PICKETT STREET
SITE PLAN ANCHORAGE, AK 99516
1"=50'
J.D. NO
017-092-69
ERMIT NO.
05PXXXXXX
HEET
1 OF 3
W (.1 (N W W W W W N N N N N N N N N N N N fJ lA1-Sate ga[pr a o vva,
W J ill 6:P- W
p EINED POR CODE G
oma tnr 3m�marn�ln�mOOz�ZOav�v�zomxzr➢- w vtnrmOwcn olnon
n
zamo Zxmimml? HxpmZ�mo� oxnmin arDmom �o-
mM>Zoo DomMm im mmymmMOrDym V ao-ov?zGr-I*o<mOcrmmF�>r��+�mO F
mmiv m�zo�,�Oo oomo�mmoaZo 0 om=v�=�mnrm*Im ��z,sMvo J0mC'v"._ nmX � mzm•_, �'^oo
D 0 0 D O Z m Z 2 p N 0 m C 0 -1 Z
M 0 DO_'Z-OV1���� OF1 -�1-Zi0-Vfrll-ZI '� O Z m Dr ytioc oNmar=zmO m.Zm1" O S�S O O(�NZZ
Fyp vZDNm�DD ➢� D �OvbZ D m m��!=omiFcvmF*Imsz�v,Mom-NiYN < z Z(rM On�-a1y z
�2m Py OD�_Z OZ00 0 m.oOR0 N ',1c mn-ID NS O_I -.O .ZI 2'.*7-➢1 In Ooz'z'IA
,,xx�I N SyMmOVN 3r N !n O r
D�Y vmov yN Av.Z01 .'SOI .ZOI Dyl1D�:i) z mnDzo➢z oFn���vz jmF�v-�Zm Ot➢iz cmi m
mF D.-y-�2m =N�=N f/1 N Vim.-.Zm VI mZ NmN ZM: 2r r�lnm mm O.Z10 m�CO r ^' iD^" �1Z--i0
➢"DON 0'-. �ZMOo rmr nZO'm" m v,oO ozmJcsmoaln.. Gommzz�v D tT�lmm2Z 2tn i2Dln
op3 yr m-OFMFr M Owe F rzm zOmF o mFcm< 3j8o zMM� � 0OM�00-F z2
coz my lv��zyvc� v 1^n�Am'I I,mi,I. rmc y-aircnsz�mmm�o pr.��czMMw Z morom-IaOF�v
�om fo>z mo oa0F vzi woF> COi � 000'Z�5MMNj2<<z mom2K6sm N O�m9ozor'1A
MMo Om1zN�� mm
m Kzzom� vO1Z �rmI o�mZl y-omof ap= poo nmy oror1av rzrlm-MEi �z mz zznz
mr -�. Nx-2mNm (/IOOy N V G fD-m �NyO 2� S m0�� Z7
�Cn N - _ 0
ASO ZD Dy�mZA� O ZD.Mwm Nf*VI� m'OZ�� 02 T.�mZ =I VrD-�D SOD mai vA op �I^Nn
N- 1 8 F2�2 20 m mKy .-mm r0Z ZI,> Z➢o1 ,0 ZnrmvON� ➢va>'0A, Pcflc„F
ZZa Oct ZmZL]"OC➢i D vr� 000 mfSi1NZ��mOf -'mo Clmzmm< r5vym d Z=ov
O y O z� O 1n m .y Fz zm m m Oz mD�el oz zO�nv 02
➢� Q�V Ampp A DCj
-u F. mO.Tml ���o CmZ ��� pRml ➢DOy'm 1Dlz �y mOfrl�Z(A
z-Z<o zw mn9 vim„ z� nm ozy mzz smmA s rm�9o<m mono izf Ow
oDmz =1 OO v_-niz'Iom➢ mymrM mw m'..lc� op oa+v �O �mz���� zm~�m-aN �uizm
mvK Oy ,�,, 0--1>;u D 1p%IZ0 �� omm ,-Zlmim NV NNmO TO.Np mZ�-i vm�A2 ZO Mc0iI�_I
mrDy am 1nFKoyOm o �Oz �2 �zz nor�� m�o" coo< D$m cmm�n�n�zyO
rn ern zn Oz2� O mmy w= mzZ mO�pMM;u �� 00 o m m O ➢-
ma:> �N �tnN mOmv OCSmSI mN ,i2 c� In P31 -M NDD Nm 0A�z >�v��m NA pzz. mOMlzm x
dmf N� p cziMEF m og�I �R. . xv- 3 � w Mc mz 8 R;>:F^Om -�Z,mn `aro o -
Z m- 0y ma O vlCv 0 v a WN D m OZmr t'Z -1O mmmm na� 00
v➢i�x uzi `� OyS KS.Tml lmll c �Ni Dz Fzm m -Or Or ai mm µ�io"�oa '� Fpmn Z'
0m� Dr aOz mA o QOF v� �Ta �nvsi x� m n•
DO SD yi�mzf*mly O�m v�KM5v 0 mC
z•n �� rlm Z- Of 1„O tnmZ x2 D m •O ay D m v- S
Vy1Dr v�0 .101Zo mZA m ."Ozp �N Ovm m2cZ Orr- m ZO OmZO N."[DI-a< >'
R-: D fm
co Z Ocmy zmy M ,m„Z -a P> FD '_i20 OMR6 0� xm mNov-OID mm N0�{z. m y
r�p*Sm Do zn�m�yo mxz mO neo Foo o<� o Zm o Dmz5MM « o'!q m ao
y y O UI 2 m to O y Z
�-aim �Woa o mmj to?" "� nmvZ mm m me zmp im000 �z pm z Ma
MM Mo
�� iy m om ME TF:2 yzr zo Z "Fvc �r'i+ o =� E"�m�nzo No MM
o cv-no
m� r x o m
O ➢ o-2< -� cz s z -a c Zfnvm mz xDUI v'I
n zm zyvmm f = zfo cN S VIM -o O� Oz '2 Mmo m cz 0N1 oy
tAZ T`O M v o D 0 0 3 f DmZz m0 ma ��azmm { Pm n a 2
Im D� zmc ow x z y a oxZom rnvM =i c � >�m y �v D`_1F Om
y Ommao myz D m moz F 2 n2� � No m<r0- m D vzz rn
m o F yaN m P m m m•
p N
MU
m0
.z.1
W
Tl
D Z10
1 A C
y
M
D
Z O
p
J
D
> `L
O O, I
Z m
m
m
oN
Z n
m
y
O
m N Z
0 I I Z
N
m
O_ n
m
z p
K
M
a 2
A 2
z c
Gl .r?
c I
r: cn m
NCnNA`�
c
In
m
0
M
v
�ZZO
O m rn
3
O�
n -*1mm Z
0 p N
2 `�
u0i i�T7 ��AN•'c'
m
A
> n
c pOm�
p ZmZ�C-)m
r Z
O V I<
0
N
cn \
O 2 Z N -
ZO
00
L7
➢
O
m
D
D n
m�-r
z
N
\
N
Gi
m n
z0
r y
W
M
m
p DO
v O
7
OO K =r1 Z�L
I
y
m?1
l
l
7m�
� m
mz �� Caw
1^m
z
K S.
m0
.z.1
p r!!I
j
Tl
D Z10
1 A C
DATE
06/12/2023
N m�
D
Z O
p
J
D
> `L
O O, I
Z m
m
m
oN
Z n
119
`-m< I m
o+
Gi
z u<i
m N Z
0 I I Z
N
< W
z p
K
M
a 2
A 2
z c
Gl .r?
c I
r: cn m
NCnNA`�
c
X
CLy "1 (� �- C1
m=.Z1
X.=O O
OO
So
T0
�ZZO
O m rn
3
O�
n -*1mm Z
0 p N
2 `�
u0i i�T7 ��AN•'c'
A
> n
c pOm�
p ZmZ�C-)m
=
O N.II W �0
1
90 -u Z 1 �:� A
O 2 Z N -
0017 O�
mei D3
o -
NOTES:
PANNONE ENG SVC, LLC (C.I. 10$$)
P.O. BOX 102954 ANCHORAGE, A 99510OFA
PHONE 907 272-8218 FAX 907 272-8211
�P,•.••
�:•�TM _*
•••• •• •• ......•
}ems annoile
CE 8149 ;
REVISIONS
DATE
06/12/2023
FOR CONSTRUCTION
m
p
N
A
4
N
LJC
P.I.D. NO
017-092-69
CHECKED
ACP
SOIL LOG/NOTES
ai
SHEET
2OF3
0
w
o
n
w
l
l
l
z
z
z
M
0
o
in
c
n
o
o1m
zr
c�
z
A
A
A
N
O
4
O
I
A
Ol
O
m
0
m
V
A
m
I
O
I
v
NOTES:
PANNONE ENG SVC, LLC (C.I. 10$$)
P.O. BOX 102954 ANCHORAGE, A 99510OFA
PHONE 907 272-8218 FAX 907 272-8211
�P,•.••
�:•�TM _*
•••• •• •• ......•
}ems annoile
CE 8149 ;
REVISIONS
DATE
06/12/2023
FOR CONSTRUCTION
EQUESTRIAN HEIGHTS BLOCK 2 LOT 18
HULTQUIST HOMES, INC.
SITE: 14225 PICKETT STREET
ANCHORAGE, AK 99516
SCALE
NTS
DRAWN
LJC
P.I.D. NO
017-092-69
CHECKED
ACP
SOIL LOG/NOTES
PERMIT N0.
osPXXXXXX
SHEET
2OF3
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
TEST HOLE 1
OR ORGANICS
VERY SILTY- FINE
GM/SM SAND W/ TRACES
OF GRAVEL
SP UNIFORM
CLEAN SAND
BOH
DATE PERFORMED: 05/23/23
TH-1
REVIEWED FOR CODE COMP,
OSP231163, Curtis Townsend,
�\ \ 10' Telecom & Elec Esmt I \
\ � I
TH-1
/ PES 05/23 23 I
78 I I I
I I I I
(FIJI /
W I
WAS GROUND WATER
ENCOUNTERED? N
IF YES, AT WHAT
DEPTH? —N/A—'
DEPTH TO WATER AFTER
MONITORING? — DRY'
DATE: 06/02/2023
SLOPE
COMMENTS: Test hole excavated by Anderson Construction & Engineering.
PERFORMED BY: PANNONE ENGINEERING. I CERTIFY THAT THIS TEST WAS
PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES
IN EFFECT ON THE DATE OF THIS TEST.
NOTES: PANNONE ENG SVC LLC (C.I. 1088)
FOR CONSTRUCTION P.O. BOX 1807 PALMER, AK 99645 OF
PHONE (907) 745-8200 FAX 907) 745-8201 p,••
*49TM•�*
DRAWN L1c EQUESTRIAN HEIGHTS BLOCK 2 LOT 18 •'. ••
CHECKED - HULTQUIST HOMES, INC. anno e
SITE: 14225 PICKETT STREET CE
814s
SOILS LOG ANCHORAGE, AK 99516
REVISIONS
TH-1
06/15/2023
CALE
NTS
J.D. NO
017-092-69
ERMIT NO.
OSPXXXXXX
HEET
3OF3
MUNICIPALITY OF ANCHORAGE
Development Services Department i
P p Phone: 907-343-7904
On -Site Water & Wastewater Section Fax: 907-343-7997
Parcel I.D. 017-092-90
Certificate of On -Site Systems Approval
Expiration Date: 2/16/2025
Legal description EQUESTRIAN HEIGHTS BLK 2 LT 18A
Site address 14225 PICKETT ST
Current property owner(s) HULTQUIST HOMES INC
X The On-site system(s) is/are approved for 5 bedrooms
Conditional approval for bedrooms, with the following stipulations:
Comments or advisories:
By: Original Certificate Date: 3/13/2024
This Certificate of On -Site Systems Approval (COSA) is intended to demonstrate the subject
system(s) is/are in substantial compliance with municipal code. The Municipality of
Anchorage, Development Services Department (DSD) issues COSAs based upon
representations provided by an independent professional engineer. The Municipality of
Anchorage is not responsible for errors or omissions in the professional engineer's work.
ATTACHMENTS:
COSA Checklist X Well Flow Advisory
Absorption Field Advisory Nitrate Advisory
Tank Age Advisory Arsenic Advisory X
Other
COSA Approval_June 2022
zMTk9rMtWV&61 •
Development Services Department
On -Site Water & Wastewater Section
Phone: 907-343-7904
Fax: 907-343-7997
Certificate of On -Site Systems Approval Application
1. GENERAL INFORMATION
Parcel I.D. 017-092-90
Complete legal description Equestrian Heights Block 2 Lot 18A
Location (site address) 14225 Pickett Street
Current property owner(s) HUltquist Homes, Inc.
2. ON-SITE SYSTEMS SIZED FOR 5 BEDROOMS
Day phone
3. TYPE OF WATER SUPPLY: 0 Private Well ❑ Private Well serving 2 dwelling units
❑ Private Well serving 3+ dwelling units ❑ Community Well or Public
❑ Water Storage
4. TYPE OF WASTEWATER DISPOSAL: W Private Septic ❑ Private Septic serving 2 dwelling units
❑ Holding Tank ❑ Community Septic or Public Sewer
5. SEPTIC TANK: ❑■ Steel ❑ Plastic ❑ Concrete ❑ Fiberglass
Age <1 - See advisory if steel older than 20 years
6. ABSORPTION FIELD: ❑ AWWTS ❑ Bed ❑ Deep Trench X Wide Trench ❑ Seepage Pit
Waiver request for:
Expedited review requested: ❑
Distance:
By applying for this entitlement, this property is subject to inspection by municipal On-site staff
to verify the accuracy of the information provided.
COSA Fee $ I -zli Waiver Fee $
Date of Payment
COSA# OSLZy ( o= n
Date of Payment
Waiver #
COSA Application—June 2022
COSA Checklist_June 2022
COSA Checklist
Legal Description: Parcel ID:
If more than 1 well and/or septic system on lot, provide separate checklist. Structure served by this system ____
A. WELL DATA
Well log is filed with Onsite (or attached)
Date drilled Total depth ft
Cased to ft
Sanitary seal is functioning correctly
Wires are properly protected
Casing height (above ground) in.
Date of flow test for COSA
Static water level at beginning of test ft.
Well production at time of test gpm
Water storage tank volume gallons
Well disinfected for coliform test? Yes No
Coliform bacteria is Negative
Nitrate mg/L Nitrate less than MRL (ND)
Arsenic ug/L Arsenic less than MRL (ND)
Collected by
Date
Comments __________________________________________________________________________________
B. TANK DATA
Measured operating fluid level in septic tank
Date of pumping
Required maintenance completed, if AWWTS
Comments:
C. LIFT STATION
Required maintenance completed
Age of lift station years
Lift station material
Comments:
D. ABSORPTION FIELD DATA
Which system tested (date installed)
ALL standpipes present per record drawing
Total measured depth from grade ft (max)
Measured depth to pipe invert from grade ft (min)
N/A – pressurized field.
Per record drawings, field is insulated.
Monitor tubes go to bottom of effective.
If not, state depth into effective
Presoaked required if
(Required if house vacant or field not used for more
than 30 days prior to date of test)
Gallons introduced gallons date
Any rejuvenation treatment (past 12 months)
If yes, enter date
Adequacy test date
Results Pass
Fluid depth prior to test in
Water added gal
New fluid depth in
Elapsed time min
Final fluid depth in
Absorption rate gpd
FIELD STATUS – POST RECOVERY
Effective depth (per record drawings) in
Effective depth used in
Effective depth remaining in
Comments/Deficiencies:
COSA Checklist_June 2022
E. SEPARATION DISTANCES
From Private Well on Lot to: (Please enter distances if less than required or if community well on lot)
Septic Tank/Lift Station on Lot > 100’
Yes if No ft
Neighboring Tank > 100’ Yes if No ft
Absorption Field on Lot > 100’ Yes if No ft
Neighboring Absorption Fields > 100’
Yes if No ft
Community Sewer Main > 75’ Yes if No ft
Community Sewer Manhole/Cleanout > 100’
Yes if No ft
Private Sewer/Septic Line > 25’ Yes if No ft
Holding Tank > 100’ Yes if No ft
Animal Containment > 50’ Yes if No ft
Manure/Animal Excreta Storage > 100’
Yes if No ft
N/A – Served by Community Well (not on lot) or Public Water
From Septic/Holding Tank and Absorption Field(s) on Lot to: (Please enter distances if less than required)
Building Foundations > 10’ Yes if No ft
Tank to Property Line > 5’ Yes if No ft
Field to Property Line > 10’ Yes if No ft
Water Main > 10’ Yes if No ft
Water Service Line > 10’ Yes if No ft
Surface Water > 100’ Yes if No ft
Wells on Adjacent Lots:
Private Wells > 100’ Yes if No ft
Community Wells > 200’ Yes if No ft
If tank or field is under driveway comment below
F.ENGINEER’S COMMENTS
G.CERTIFICATION & STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based
on procedures outlined in the Certificate of On-Site Systems Approval Guidelines, indicates that the on-site water
supply and/or wastewater disposal system appears to comply with applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation, unless noted otherwise.
Name of Firm Phone
Engineer’s Printed Name Date
2024.03.11
Arsenic Advisory
Certificate of On -Site Systems Approval # OSC241058
Subdivision: Equestrian Heights, Block: 2, Lot: 18A
A water sample revealed an arsenic concentration of 23.5 micrograms per liter
(ug/L). The Environmental Protection Agency (EPA) has established a maximum
contaminant level (MCL) of 10.0 ug/L for public drinking water systems. While
private wells are not subject to this regulation, EPA standards are based on existing
health information and can therefore be used to gauge the relative quality of water
from private wells. information on arsenic is available from the On -Site Water and
Wastewater Program website (www.muni.org/onsite) or at 343-7904.
This advisory must be attached to all copies of the subject Certificate of On -Site
Systems Approval.
u