Loading...
HomeMy WebLinkAboutEQUESTRIAN HEIGHTS BLK 2 LT 18AA HEIGHTS a� Municipality of Anchorage On-Site Water and Wastewater Section • (907) 343-7904 Page 1 of 2 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP231163 PID Number: 017-092-90 Dwelling: ❑■ Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: X New ❑ Upgrade Name Hultquist Homes, Inc. ABSORPTION FIELD ❑ Deep Trench 0 Wide Trench ❑ Bed ❑ Mound Site Address 14225 Picket Street ❑ Other Phone Number of Bedrooms Soil RatingTotal depth from original grade 5 �•8 GPD/SF 6.0 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade 2.0 Ft. Gravel depth beneath pipe 4.0 Ft. Subdivision Block Lot Equestrian Heights 2 18A Fill added above original grade 0.7 Ft. Gravel length 2@47 Ft. Township Range Section Gravel width 5.0 Ft Beds: Number of Lines n/a Distance between lines n/a Ft. SEPARATION DISTANCES To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Tank Line 940 Ft2 2 8.0 Ft. Well 100'+ 100'+ 100'+ NA 25'+ TANK ❑ Septic X S.T.E.P. ❑ Holding ❑ Other Manufacturer Anchorage Tank Capacity 2500 Gal. Surface Water 100'+ 100'+ 100'+ NA Material Number of compartments Lot Line 10'+ 101+ 10'+ NA NA Steel 2 Foundation 10'+ 10'+ 10'+ NA LIFT STATION Manufacturer Capacity Remarks Field installed w/2.0" insulation Orenco 250 Gal. Alarm location Inside Attached Garage Electrical installed by Dependable Services Installer PIPE MATERIAL House to tank 3034 Tank to ASTM D1785 drainfield Hultquist Homes, Inc. Drainfield ASTM D1785 Co/MT3034 Inspector PES BENCH MARK (Assumed elevation) 100.0 ft Inspect tiosn v 06/22/23 06/23/23 Location and description 2nd 31d 06/26/23 40' 03/08/24 See Site Plan, Bottom Trim House corner ON-SITE WATER AND WASTEWATER SECTION APPROVAL Engineer's Stamp Conditional Approval: Date P• ' ... .. ....... even annope •. CE 8149 ; Septic Syste Approved Date 3 '••:024.°3.':••' . ,AIOFB' Note: this approve I does not include well permit requirements. PROFILE PA N N O N E E N G S V C , L L C ( C . I . 1 0 8 8 ) As Built Land Surveying Land Development Consultants Subdivision Specialists Construction Surveying AEC# 173042 S4 Group 124 E 7th Avenue Anchorage, Alaska 99501 (907) 306-8104 mail@S4AK.com Lot Lot 18A, Block 2, Equestrian Heights Subdivision 02/22/2024 017-092-90 017-092-90 MUNICIPALITY OF ANCHORAGE relent s On -Site Water & Wastewater Program 'o PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite J I 1)ehaI-tIII e11t On -Site Water & Wastewater System Permit Permit Number: OSP231163 Effective Date: 6/16/2023 Work Type: WellSeptic Initial Expiration Date: 6/15/2024 Tax Code Number: 01709269000 Site Legal Address: EQUESTRIAN HEIGHTS BLK 2 LT 18 G:3038 Site Mailing Address: 14225 PICKETT ST, Anchorage Owner: HULTQUIST HOMES INC Lot Size in Sq Ft: 22577 Design Engineer: PANNONE ENGINEERING SERVICES Total Bedrooms: 5 This permit is for the construction of: Q Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy Q Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Special Provisions: 7 day groundwater monitoring was not completed in test hole 2 in the area of the proposed trench. Verify groundwater in this prior to proceeding with installation of the field. If results require a design change, construction shall stop pending approval of a change order. Please submit results with the inspection report (or change order, if required). Received By: >SV�J��S Date: 20 Issued By: Date: b Z 3 MUNICIPALITY ALITY OF ANCHORAGE R vs H Community Development Department `° = c Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On -Site Water & Wastewater Program ON-SITE SEWERIWELL PERMIT APPLICATION Parcel I.D. 017-092-69 Property owner(s) Hultquist Homes, Inc. Day phone Mailing address Site address 14225 Pickett Street Legal description (Sub's., Block & Lot) Equestrian Heights Block 2 Lot 18 Legal description (Township, Range & Section) Lot Size 22,577 Sq. Ft. Number of Bedrooms 5 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (N all that apply) Absorption FieldX❑ Initial I—XI Single Family (SF) X❑ Septic Tank X❑ Upgrade ❑ (w/wo AD U) Holding Tank ❑ Renewal Duplex (D) ❑ ❑ Privy ❑ Multiple Dwellings ❑ (SF and/or D) Private Well X❑ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. SRP (Signature of property owner or authorized agent) Permit/Rush Fees: - / 3 Z Waiver Fees: Date of Payment: Date of Payment: Receipt Number: Receipt Number: Permit No. 0-'5 P 2'5 1163 Waiver No. Permit App_::- : ,_.,:c Wricipality of Pndiorage On-site Water and Wastewater REVIEWED FOR CODE COtUI UMC OSP231163, Curtis Townsend, 06116) Steven R. Pannone, Principal Registered Professional Engineer E-mail: steve@paneneak.com 15 June 2023 Municipality of Anchorage Development Services Department On -Site Water & Wastewater Program 4700 Elmore Road P. O. Box 196650 Anchorage, Alaska 99519 Subject: Equestrian Heights Block 2 Lot 18 Well & Septic System Permit Request Septic System Design Narrative This is a design narrative for a permit to install an initial septic system on the subject property. The proposed system will serve a proposed five -bedroom (5) house. This lot and surrounding lots are served by private wells. Currently there are no wells within 100 feet of the proposed system. 1. Soils: Two test holes were performed on this lot by Pannone Engineering Services, LLC on (TH-105/23/2023) and (TH-2 06/06/2023). Groundwater was not observed during the excavation of test hole (1), and bedrock was not encountered. No groundwater was observed in this test hole monitor tube after 7 -days. Based on the overall soils appearance and percolation test results of test hole (2); an application rate of 0.8 gpd/SF was used for the design of a conventional wastewater treatment system in the area of test hole (2). 2. Soil Absorption System Design. a. See Sheet 1 of the design package. 3. Surface Water: There is no surface water within 100 feet of the proposed septic tank and drain field. 4. Topography: See attached site plan for area topography. There are no slopes exceeding 25% within 50ft of the proposed drain field. Mailing: P.O.Box 1807, Palmer, AK 99645 Telephone: (907) 745-8200 FAX: (907) 745-8201 Page 2 of 2 5. Drawing Markings: The Drawings are marked "For MOA Review Only". When written notification that the review is complete and no further comments are received from MoA On -Site Department, the note will be removed and "For Construction" drawings will be issued. The proposed installation will not affect the future development of this or the surrounding lots. If you have any questions or concerns, please contact me at (907) 745-8200. Sincerely, �1 Steven R. Pannone, P.E. F. ASCE Owner/Civil Engineer Mailing: P.O.Box 1807, Palmer, AK 99645 Telephone: (907) 745-8200 FAX: (907) 745-8201 -�j c�i1 n 0-- = D I Q)\w V1 Z Z7 -I D --I ^ C D1'Li)t co CO Ocn(n DTrilm [7>00mDprn Z� yr �z' m ONcn Dvm om�70OmDO� �or--Clx;;DOmm vyi c r x r O7 x m 0->0 (nm< cn r .p r O CO D z 1113 v, "D z �O zC ZN �p -Vl < D I I DUD o m N C7 m �m'o G)O -..I N D� X XO m -0 O -.. I D 0v m0ZrnJ Z = CO Dx pOm D cn OX Gp mr U-1 O o O —41 o C r i ��, =ayoz JD / _w m I I 0>OClp pm0 pWZpm � —0 0 Z D O ---I co '0- � O ox -�' Oo -AN� r CJi -I i0 Cl) I o N �lO �� Z O � � IZ���D m�� o m rCf) \ TQ -ci z o _ Cn D° a m rn _ m� a FTI m u12r n OD mO _U I X Nv Z) U) I I r C7 C7T7 0 Pq I r Rl- 4- M OL- PICKETF �S-TREET Z oa— � PAVED D IVE (P) b as o� I 1 L DO O Cprq o , o ry J / N3 co a DRAWN L,1C EQUESTRIAN HEIGHTS BLOCK 2 LOT 18 CHECKED ACP HULTQUIST HOMES, INC. SITE: 14225 PICKETT STREET SITE PLAN ANCHORAGE, AK 99516 1"=50' J.D. NO 017-092-69 ERMIT NO. 05PXXXXXX HEET 1 OF 3 Q)\w LJ y � Elec E/smf my i ��, =ayoz / _w I w >Aa o�-Nm rn I m u12r n OD mO I Nv Z) -j I I Pq n�r " oho I I — 1 m C)o ---- I L— I �o NOTES: PANNONE ENG SVC LLC (C.I. 1088) P.O. BOX 1807 PALfv�ER, AK 99645 REVISIONS DATE 06/15/2023 for construction PHONE (907) 745-8200 FAX (907) 745-8201 �OFA�, �P.•''• �'•. -1► crei r DRAWN L,1C EQUESTRIAN HEIGHTS BLOCK 2 LOT 18 CHECKED ACP HULTQUIST HOMES, INC. SITE: 14225 PICKETT STREET SITE PLAN ANCHORAGE, AK 99516 1"=50' J.D. NO 017-092-69 ERMIT NO. 05PXXXXXX HEET 1 OF 3 W (.1 (N W W W W W N N N N N N N N N N N N fJ lA1-Sate ga[pr a o vva, W J ill 6:P- W p EINED POR CODE G oma tnr 3m�marn�ln�mOOz�ZOav�v�zomxzr➢- w vtnrmOwcn olnon n zamo Zxmimm­l? HxpmZ�mo� oxnmin arDmom �o- mM>Zoo DomMm im mmymmMOrDym V ao-ov?zGr-I*o<mOcrmmF�>r��+�mO F mmiv m�zo�,�Oo oomo�mmoaZo 0 om=v�=�mnrm*Im ��z,sMvo J0mC'v"._ nmX � mzm•_, �'^oo D 0 0 D O Z m Z 2 p N 0 m C 0 -1 Z M 0 DO_'Z-OV1���� OF1 -�1-Zi0-Vfrll-ZI '� O Z m Dr ytioc oNmar=zmO m.Zm1" O S�S O O(�NZZ Fyp vZDNm�DD ➢� D �OvbZ D m m��!=omiFcvmF*Imsz�v,Mom-NiYN < z Z(rM On�-a1y z �2m Py OD�_Z OZ00 0 m.oOR0 N ',1c mn-ID NS O_I -.O .ZI 2'.*7-➢1 In Ooz'z'IA ,,xx�I N SyMmOVN 3r N !n O r D�Y vmov yN Av.Z01 .'SOI .ZOI Dyl1D�:i) z mnDzo➢z oFn���vz jmF�v-�Zm Ot➢iz cmi m mF D.-y-�2m =N�=N f/1 N Vim.-.Zm VI mZ NmN ZM: 2r r�lnm mm O.Z10 m�CO r ^' iD^" �1Z--i0 ➢"DON 0'-. �ZMOo rmr nZO'm" m v,oO ozmJcsmoaln.. Gommzz�v D tT�lmm2Z 2tn i2Dln op3 yr m-OFMFr M Owe F rzm zOmF o mFcm< 3j8o zMM� � 0OM�00-F z2 coz my lv��zyvc� v 1^n�Am'I I,mi,I. rmc y-aircnsz�mmm�o pr.��czMMw Z morom-IaOF�v �om fo>z mo oa0F vzi woF> COi � 000'Z�5MMNj2<<z mom2K6sm N O�m9ozor'1A MMo Om1zN�� mm m Kzzom� vO1Z �rmI o�mZl y-omof ap= poo nmy oror1av rzrlm-MEi �z mz zznz mr -�. Nx-2mNm (/IOOy N V G fD-m �NyO 2� S m0�� Z7 �Cn N - _ 0 ASO ZD Dy�mZA� O ZD.Mwm Nf*VI� m'OZ�� 02 T.�mZ =I VrD-�D SOD mai vA op �I^Nn N- 1 8 F2�2 20 m mKy .-mm r0Z ZI,> Z➢o1 ,0 ZnrmvON� ➢va>'0A, Pcflc„F ZZa Oct ZmZL]"OC➢i D vr� 000 mfSi1NZ��mOf -'mo Clmzmm< r5vym d Z=ov O y O z� O 1n m .y Fz zm m m Oz mD�el oz zO�nv 02 ➢� Q�V Ampp A DCj -u F. mO.Tml ���o CmZ ��� pRml ➢DOy'm 1Dlz �y mOfrl�Z(A z-Z<o zw mn9 vim„ z� nm ozy mzz smmA s rm�9o<m mono izf Ow oDmz =1 OO v_-niz'Iom➢ mymrM mw m'..lc� op oa+v �O �mz���� zm~�m-aN �uizm mvK Oy ,�,, 0--1>;u D 1p%IZ0 �� omm ,-Zlmim NV NNmO TO.Np mZ�-i vm�A2 ZO Mc0iI�_I mrDy am 1nFKoyOm o �Oz �2 �zz nor�� m�o" coo< D$m cmm�n�n�zyO rn ern zn Oz2� O mmy w= mzZ mO�pMM;u �� 00 o m m O ➢- ma:> �N �tnN mOmv OCSmSI mN ,i2 c� In P31 -M NDD Nm 0A�z >�v��m NA pzz. mOMlzm x dmf N� p cziMEF m og�I �R. . xv- 3 � w Mc mz 8 R;>:F^Om -�Z,mn `aro o - Z m- 0y ma O vlCv 0 v a WN D m OZmr t'Z -1O mmmm na� 00 v➢i�x uzi `� OyS KS.Tml lmll c �Ni Dz Fzm m -Or Or ai mm µ�io"�oa '� Fpmn Z' 0m� Dr aOz mA o QOF v� �Ta �nvsi x� m n• DO SD yi�mzf*mly O�m v�KM5v 0 mC z•n �� rlm Z- Of 1„O tnmZ x2 D m •O ay D m v- S Vy1Dr v�0 .101Zo mZA m ."Ozp �N Ovm m2cZ Orr- m ZO OmZO N."[DI-a< >' R-: D fm co Z Ocmy zmy M ,m„Z -a P> FD '_i20 OMR6 0� xm mNov-OID mm N0�{z. m y r�p*Sm Do zn�m�yo mxz mO neo Foo o<� o Zm o Dmz5MM « o'!q m ao y y O UI 2 m to O y Z �-aim �Woa o mmj to?" "� nmvZ mm m me zmp im000 �z pm z Ma MM Mo �� iy m om ME TF:2 yzr zo Z "Fvc �r'i+ o =� E"�m�nzo No MM o cv-no m� r x o m O ➢ o-2< -� cz s z -a c Zfnvm mz xDUI v'I n zm zyvmm f = zfo cN S VIM -o O� Oz '2 Mmo m cz 0N1 oy tAZ T`O M v o D 0 0 3 f DmZz m0 ma ��azmm { Pm n a 2 Im D� zmc ow x z y a oxZom rnvM =i c � >�m y �v D`_1F Om y Ommao myz D m moz F 2 n2� � No m<r0- m D vzz rn m o F yaN m P m m m• p N MU m0 .z.1 W Tl D Z10 1 A C y M D Z O p J D > `L O O, I Z m m m oN Z n m y O m N Z 0 I I Z N m O_ n m z p K M a 2 A 2 z c Gl .r? c I r: cn m NCnNA`� c In m 0 M v �ZZO O m rn 3 O� n -*1mm Z 0 p N 2 `� u0i i�T7 ��AN•'c' m A > n c pOm� p ZmZ�C-)m r Z O V I< 0 N cn \ O 2 Z N - ZO 00 L7 ➢ O m D D n m�-r z N \ N Gi m n z0 r y W M m p DO v O 7 OO K =r1 Z�L I y m?1 l l 7m� � m mz �� Caw 1^m z K S. m0 .z.1 p r!!I j Tl D Z10 1 A C DATE 06/12/2023 N m� D Z O p J D > `L O O, I Z m m m oN Z n 119 `-m< I m o+ Gi z u<i m N Z 0 I I Z N < W z p K M a 2 A 2 z c Gl .r? c I r: cn m NCnNA`� c X CLy "1 (� �- C1 m=.Z1 X.=O O OO So T0 �ZZO O m rn 3 O� n -*1mm Z 0 p N 2 `� u0i i�T7 ��AN•'c' A > n c pOm� p ZmZ�C-)m = O N.II W �0 1 90 -u Z 1 �:� A O 2 Z N - 0017 O� mei D3 o - NOTES: PANNONE ENG SVC, LLC (C.I. 10$$) P.O. BOX 102954 ANCHORAGE, A 99510OFA PHONE 907 272-8218 FAX 907 272-8211 �P,•.•• �:•�TM _* •••• •• •• ......• }ems annoile CE 8149 ; REVISIONS DATE 06/12/2023 FOR CONSTRUCTION m p N A 4 N LJC P.I.D. NO 017-092-69 CHECKED ACP SOIL LOG/NOTES ai SHEET 2OF3 0 w o n w l l l z z z M 0 o in c n o o1m zr c� z A A A N O 4 O I A Ol O m 0 m V A m I O I v NOTES: PANNONE ENG SVC, LLC (C.I. 10$$) P.O. BOX 102954 ANCHORAGE, A 99510OFA PHONE 907 272-8218 FAX 907 272-8211 �P,•.•• �:•�TM _* •••• •• •• ......• }ems annoile CE 8149 ; REVISIONS DATE 06/12/2023 FOR CONSTRUCTION EQUESTRIAN HEIGHTS BLOCK 2 LOT 18 HULTQUIST HOMES, INC. SITE: 14225 PICKETT STREET ANCHORAGE, AK 99516 SCALE NTS DRAWN LJC P.I.D. NO 017-092-69 CHECKED ACP SOIL LOG/NOTES PERMIT N0. osPXXXXXX SHEET 2OF3 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 TEST HOLE 1 OR ORGANICS VERY SILTY- FINE GM/SM SAND W/ TRACES OF GRAVEL SP UNIFORM CLEAN SAND BOH DATE PERFORMED: 05/23/23 TH-1 REVIEWED FOR CODE COMP, OSP231163, Curtis Townsend, �\ \ 10' Telecom & Elec Esmt I \ \ � I TH-1 / PES 05/23 23 I 78 I I I I I I I (FIJI / W I WAS GROUND WATER ENCOUNTERED? N IF YES, AT WHAT DEPTH? —N/A—' DEPTH TO WATER AFTER MONITORING? — DRY' DATE: 06/02/2023 SLOPE COMMENTS: Test hole excavated by Anderson Construction & Engineering. PERFORMED BY: PANNONE ENGINEERING. I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THE DATE OF THIS TEST. NOTES: PANNONE ENG SVC LLC (C.I. 1088) FOR CONSTRUCTION P.O. BOX 1807 PALMER, AK 99645 OF PHONE (907) 745-8200 FAX 907) 745-8201 p,•• *49TM•�* DRAWN L1c EQUESTRIAN HEIGHTS BLOCK 2 LOT 18 •'. •• CHECKED - HULTQUIST HOMES, INC. anno e SITE: 14225 PICKETT STREET CE 814s SOILS LOG ANCHORAGE, AK 99516 REVISIONS TH-1 06/15/2023 CALE NTS J.D. NO 017-092-69 ERMIT NO. OSPXXXXXX HEET 3OF3 MUNICIPALITY OF ANCHORAGE Development Services Department i P p Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Parcel I.D. 017-092-90 Certificate of On -Site Systems Approval Expiration Date: 2/16/2025 Legal description EQUESTRIAN HEIGHTS BLK 2 LT 18A Site address 14225 PICKETT ST Current property owner(s) HULTQUIST HOMES INC X The On-site system(s) is/are approved for 5 bedrooms Conditional approval for bedrooms, with the following stipulations: Comments or advisories: By: Original Certificate Date: 3/13/2024 This Certificate of On -Site Systems Approval (COSA) is intended to demonstrate the subject system(s) is/are in substantial compliance with municipal code. The Municipality of Anchorage, Development Services Department (DSD) issues COSAs based upon representations provided by an independent professional engineer. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. ATTACHMENTS: COSA Checklist X Well Flow Advisory Absorption Field Advisory Nitrate Advisory Tank Age Advisory Arsenic Advisory X Other COSA Approval_June 2022 zMTk9rMtWV&61 • Development Services Department On -Site Water & Wastewater Section Phone: 907-343-7904 Fax: 907-343-7997 Certificate of On -Site Systems Approval Application 1. GENERAL INFORMATION Parcel I.D. 017-092-90 Complete legal description Equestrian Heights Block 2 Lot 18A Location (site address) 14225 Pickett Street Current property owner(s) HUltquist Homes, Inc. 2. ON-SITE SYSTEMS SIZED FOR 5 BEDROOMS Day phone 3. TYPE OF WATER SUPPLY: 0 Private Well ❑ Private Well serving 2 dwelling units ❑ Private Well serving 3+ dwelling units ❑ Community Well or Public ❑ Water Storage 4. TYPE OF WASTEWATER DISPOSAL: W Private Septic ❑ Private Septic serving 2 dwelling units ❑ Holding Tank ❑ Community Septic or Public Sewer 5. SEPTIC TANK: ❑■ Steel ❑ Plastic ❑ Concrete ❑ Fiberglass Age <1 - See advisory if steel older than 20 years 6. ABSORPTION FIELD: ❑ AWWTS ❑ Bed ❑ Deep Trench X Wide Trench ❑ Seepage Pit Waiver request for: Expedited review requested: ❑ Distance: By applying for this entitlement, this property is subject to inspection by municipal On-site staff to verify the accuracy of the information provided. COSA Fee $ I -zli Waiver Fee $ Date of Payment COSA# OSLZy ( o= n Date of Payment Waiver # COSA Application—June 2022 COSA Checklist_June 2022 COSA Checklist Legal Description: Parcel ID: If more than 1 well and/or septic system on lot, provide separate checklist. Structure served by this system ____ A. WELL DATA Well log is filed with Onsite (or attached) Date drilled Total depth ft Cased to ft Sanitary seal is functioning correctly Wires are properly protected Casing height (above ground) in. Date of flow test for COSA Static water level at beginning of test ft. Well production at time of test gpm Water storage tank volume gallons Well disinfected for coliform test? Yes No Coliform bacteria is Negative Nitrate mg/L Nitrate less than MRL (ND) Arsenic ug/L Arsenic less than MRL (ND) Collected by Date Comments __________________________________________________________________________________ B. TANK DATA Measured operating fluid level in septic tank Date of pumping Required maintenance completed, if AWWTS Comments: C. LIFT STATION Required maintenance completed Age of lift station years Lift station material Comments: D. ABSORPTION FIELD DATA Which system tested (date installed) ALL standpipes present per record drawing Total measured depth from grade ft (max) Measured depth to pipe invert from grade ft (min) N/A – pressurized field. Per record drawings, field is insulated. Monitor tubes go to bottom of effective. If not, state depth into effective Presoaked required if (Required if house vacant or field not used for more than 30 days prior to date of test) Gallons introduced gallons date Any rejuvenation treatment (past 12 months) If yes, enter date Adequacy test date Results Pass Fluid depth prior to test in Water added gal New fluid depth in Elapsed time min Final fluid depth in Absorption rate gpd FIELD STATUS – POST RECOVERY Effective depth (per record drawings) in Effective depth used in Effective depth remaining in Comments/Deficiencies: COSA Checklist_June 2022 E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well on lot) Septic Tank/Lift Station on Lot > 100’ Yes if No ft Neighboring Tank > 100’ Yes if No ft Absorption Field on Lot > 100’ Yes if No ft Neighboring Absorption Fields > 100’ Yes if No ft Community Sewer Main > 75’ Yes if No ft Community Sewer Manhole/Cleanout > 100’ Yes if No ft Private Sewer/Septic Line > 25’ Yes if No ft Holding Tank > 100’ Yes if No ft Animal Containment > 50’ Yes if No ft Manure/Animal Excreta Storage > 100’ Yes if No ft N/A – Served by Community Well (not on lot) or Public Water From Septic/Holding Tank and Absorption Field(s) on Lot to: (Please enter distances if less than required) Building Foundations > 10’ Yes if No ft Tank to Property Line > 5’ Yes if No ft Field to Property Line > 10’ Yes if No ft Water Main > 10’ Yes if No ft Water Service Line > 10’ Yes if No ft Surface Water > 100’ Yes if No ft Wells on Adjacent Lots: Private Wells > 100’ Yes if No ft Community Wells > 200’ Yes if No ft If tank or field is under driveway comment below F.ENGINEER’S COMMENTS G.CERTIFICATION & STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines, indicates that the on-site water supply and/or wastewater disposal system appears to comply with applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation, unless noted otherwise. Name of Firm Phone Engineer’s Printed Name Date 2024.03.11 Arsenic Advisory Certificate of On -Site Systems Approval # OSC241058 Subdivision: Equestrian Heights, Block: 2, Lot: 18A A water sample revealed an arsenic concentration of 23.5 micrograms per liter (ug/L). The Environmental Protection Agency (EPA) has established a maximum contaminant level (MCL) of 10.0 ug/L for public drinking water systems. While private wells are not subject to this regulation, EPA standards are based on existing health information and can therefore be used to gauge the relative quality of water from private wells. information on arsenic is available from the On -Site Water and Wastewater Program website (www.muni.org/onsite) or at 343-7904. This advisory must be attached to all copies of the subject Certificate of On -Site Systems Approval. u Mailing Address P O Box 196650` AncF�arage, Alaska 99519 6650 * www murn org