HomeMy WebLinkAboutCANYON VIEW ESTATES BLK 2 LT 8I- • r-- • • �, • �� t: Municipality of Anchorage On -Site Water and Wastewater Section • (907) 343-7904 Page 1 of 2 ON -SITE WASTEWATER INSPECTION REPORT Permit Number: OSP231164 PID Number: 042-081-43 Dwelling: 0 Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: 9 New ❑ Upgrade Name Hultquist Homes, Inc. ABSORPTION FIELD ❑ Deep Trench 0 Wide Trench ❑ Bed ❑ Mound Site Address 13868 Canyon Road ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 3 1.2 GPD/SFJ 3.0 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade 1 Ft. Gravel depth beneath pipe 2 Ft. Subdivision Block Lot Canyon View Estates 2 8 Fill added above original grade 31 Ft. Gravel length 60 Ft. Township Range Section Gravel width 5.0 Ft. Beds: Number of Lines n/a Distance between lines n/a Ft. SEPARATION DISTANCES To Septic Absorption Lift Station Holding Sewer I Total absorption area Number of trenches Dist. between trenches From Tank Field Tank Line 429 Ftz 1 n/a Ft. Well 100'+ 100'+ NA NA 25'+ TANK X Septic ❑ S.T.E.P. ❑ Holding ❑ Other Manufacturer GREER Capacity 1000 Gal. Surface Water 100'+ 100'+ NA NA Material Number of compartments Lot Line 10'+ 10'+ NA NA NA HDPE 2 Foundation 10'+ 10'+ NA NA LIFT STATION Manufacturer Capacity Remarks Gal. Alarm location Electrical installed by Installer PIPE MATERIAL House to tank 3034 Tank to 3034 drainfield Brownson Bros, LLC. Drainfield 3034 CO/MT3034 Inspector PES BENCH MARK (Assumed elevation) 100.0 ft Inspdection vt 02/29/24 d 02/29/24 Location and description 2 srd 03/06/24 4'h 03/14/24 See Site Plan, Bottom of House trim ON -SITE WATER AND WASTEWATER SECTION APPROVAL Engineers Stamp Conditional Approval: Date ,�,..,• .... .. .. ....... 'even annoAe CE 8149 '•••2 024.03.12�•• Septic System Approved Date 2 /ho Z' Note: this approval does not include well permit requireme ts. �_.. k .�v �� 1000 GAL GREER POLY TANK PROFILE PA N N O N E E N G S V C , L L C ( C . I . 1 0 8 8 ) Lot 8, Block 2, Canyon View Estates Subdivision As Built Land Surveying Land Development Consultants Subdivision Specialists Construction Surveying AEC# 173042 S4 Group 124 E 7th Avenue Anchorage, Alaska 99501 (907) 306-8104 mail@S4AK.com 03/11/2024 www.sullivanwaterwells.com Pump Installation Log Well Drilling Permit Number: SW OSP231164 Date of Issue 7-11-23 Parcel Identification Number: 04208143000 Legal Description Property Owner Name & Address CANYON VIEW BLOCK 2 LOT 8 HULTQUIST HOMES Pump Installation Date: 3-12-24 Pump Intake Depth Below Top of Well Casing: 132 feet Pump manufacturer’s Name: GRUNDFOS Pump Model: 10SQE07-240 Pump Size: 3/4 hp Pitless Adapter Burial Depth: 12 feet Pitless Adapter Installer: BROWNSON BROS. Disinfected Upon Completion? yes no Method of Disinfection: Chlorine 50 PPM Comments: Pitless Manufacturer: MARTINSON Pump Installers Name: Sullivan Water Wells Attention: The pump installer shall provide a pump installation log to the DSD within 30 days of pump installation. Certified Drilling Log OWNER OF LAND: Hultquist ADDRESS: 13868 Canyon Rd. Anchorage, AK 99516 LEGAL DESCRIPTION CANYON VIEW ESTATES BLK 2 LT 8 DATE: 10/30/23 PERMIT NUMBER: OSP231164 DATE OF ISSUE: 7/11/23 TAX IDENTIFICATION NUMBER 04208143000 Is well located at approved permit location: Yes No Method of Drilling: air rotary cable tool Depth of Well: 145’ Casing Type: Steel Wall thickness .250 inches Diameter: 6 inches, depth 124 feet Liner type Static Water Level: 89 feet Recovery Rate 6 gpm gph Method of Testing Air Well Intake Opening Type: open end open hole Screened Start feet Stopped Perforations Start feet Stopped Grout Type: Bentonite Volume: 50 lbs. Depth: from feet, to feet Well Disinfected Upon Completion: yes no Method of Disinfection: Chlorine 50 PPM Comments: Bore Hole Data Depth From To 0 2 Casing Stickup 2 4 Overburden 4 10 Sand and gravel 10 18 Gravel silt water 18 30 Silty sand gravel water 30 38 Silty sand some gravel 38 60 Silty sand some gravel water 60 118 Hardpan with clay 118 145 Broken bedrock Drillers Name: Cole Sullivan ATTENTION: It is the responsibility of the property owner to submit a copy of the well log to the proper authority. Municipality of Anchorage: Department of Health & Human Services and/or Department of Environmental Conservation. MatSu Borough: Department of Environmental Conservation. MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Water & Wastewater System Permit Permit Number: OSP231164 Work Type: WellSeptic Initial Tax Code Number: 04208143000 Site Legal Address: CANYON VIEW ESTATES BLK 2 LT 8 G:3042 Site Mailing Address: 13868 CANYON RD, Anchorage Owner: HULTQUIST HOMES INC Design Engineer: PANNONE ENGINEERING SERVICES This permit is for the construction of: Q Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy Effective Date Expiration Date: Hunt S UCI)�ll'Clll�ilt 7/11/2023 7/10/2024 Lot Size in Sq Ft: 67265 Total Bedrooms: i31 �7 Q Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing 0- J_ I NC P-0 o/ti CGvn/� Received By: S S� II r Issued By: V1ti Date: Date: /Ij ZG23 MUNICIPALITY OF ANCHORAGE Community Development Department - Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On -Site Water & Wastewater Program ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 042-081-43 Property owner(s) Hultquist Homes, Inc. Day phone _ Mailing address 12570 Old Seward Highway Anchorage, AK 99515 Site address 13868 Canyon Road Legal description (Sub'd., Block & Lot) Canyon View Estates Block 2 Lot 8 Legal description (Township, Range & Section) Lot Size 67,265 Sq. Ft. Number of Bedrooms APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (® all that apply) Absorption FieldX❑ Initial X❑ Single Family (SF) X❑ Septic Tank X❑ Upgrade ❑ (w/wo ADU) Duplex (D) E]Holding Tank El Renewal El Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well X❑ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: Waiver Fees: Date of Payment: lb 2v Z13 Date of Payment: Receipt Number: $ n Ci Receipt Number: Permit No. OS p2-�, l l H `i Waiver No. Permit App_'- : . L.A Pannone Engineering Services LLC Steven R. Pannone, Principal Registered Professional Engineer J E-mail: steve(cDpanengak.com 11 September 2023 Municipality of Anchorage Development Services Department On -Site Water & Wastewater Program 4700 Elmore Road P.O. Box 196650 Anchorage, Alaska 99519 Subject: Canyon View Estates Block 2 Lot 8 Well & Septic System Permit Request Septic System Design Narrative This is a design narrative for a permit to install an initial well and septic system on the subject property. The proposed system will serve a proposed four-bedroom (4) house. Currently the lot is undeveloped. This lot and surrounding lots are served by private wells. Currently there are no wells within 100 feet of the proposed system. 1. Soils: A test hole was performed on this lot by Pannone Engineering Services, LLC in May of 2023. Groundwater was not observed during the excavation of the test hole, and bedrock was not encountered. Groundwater was observed in the test hole monitor tube after 7 -days at a level of (7.0') below grade on (05/25/2023). Based on the results of the percolation tests, overall soils appearance, and the selection of the proposed drain field; an application rate of 1.2 gallons/day/square feet was used for a conventional wastewater system in the area of the test hole. 2. Soil Absorption System Design. a. See Sheet 1 of the design package. 3. Surface Water: There is no surface water within 100' of proposed septic system. 4. Topography: See attached site plan for area topography. 5. Drawing Markings: The Drawings are marked "For MOA Review Only". When written notification that the review is complete and no further comments are received from MoA On -Site Department, the note will be removed and "For Construction" drawings will be issued. The proposed installation will not affect the future development of this or the surrounding lots. If you have any questions or concerns, please contact me at (907) 745-8200. Sincerely, SRP Steven R. Pannone, P.E. F. ASCE Owner/Civil Engineer Mailing: P.O.Box 1807, Palmer, AK 99645 Telephone: (907) 745-8200 FAX: (907) 745-8201 DESIGN PARAMETERS PRIMARY/RESERVE SEPTIC SYSTEM NO. BEDROOM: 4(600 gpd) TANK SIZE: 1250gal PERC RATE: <1 MPI SOIL RATING: 1.2 GPD/SF AREA RQD: 500 SF SYS. TYPE: WIDE TRENCH 2.0' ED RF: 0.70 MIN LENGTH: 70 LF USE: 75LFx5.0'Wx2.0'E.Dx3.0'TD TOTAL AREA: 535 SF TH-31 /v -'/ Lot 8 � DRIVEWAY 4' 1220 / \ \ / \ 4BRHOUSE \ TH-2023-8 \ H�v v/ \ • \ I \ I \ \ INSTALL 1250 al S PTIC TANK P \ / \ INSTALL FC BEFORE AND DCO AFTER. 1 \ \ IF BOTTOM OF TANK WILL BE AT A GREATER DEPTH THAN 8.0' BELOW \ 1200 ORIGINAL GRADE INSTALL STEEL TANK. \ IF PLASTIC TANK IS USED INSTALL \ \ MONITOR TUBE. \ \ 1180 \ PRIMARY HES-RVE DRAIN FIELD P 75LF x 5.0'W 2.0'ED 3.O'TD \ x x \ INSTALL CLEAN OUT AND MONITOR TUBE L O t AT EACH END. \ \ \ ENSURE MIN. 3.0' OF COVER OR R.I. \ \ PER 15.65 (3.• 1 SLOPE ON FILL) \ \ MIN. 6.0' SEPARATION BETWEEN PRIMARY \ AND RESERVE TRENCHES I \ I \ l � NOTES: PANNONE ENG SVC LLC P.O. BOX 100217 ANCHORAGE, AK 99510 PHONE (907) 272-8218 FAX (907) 272-8211 Q'�•'" *: •� :* .... .. . ....... ••$even anrio�e Date 9/15/2023 FOR CONSTRUCTION Scale 1 "=50' CANYON VIEW ESTATES, BLOCK 2, LOT 8 HULTOUIST HOMES INC. P.I.D. NO 042-081-43 DRAWN BY: DRM PERMIT No. 13868 CANYON ROAD CE 8149$ osPxxxxxx Sheet PLAN ANCHORAGE, AK '•••••'' 1 OF 3 SPECIAL PROVISIONS TO SPECIFICATIONS OI, -site Water and Wast 1. SCOPE AND SPECIFICATIONS: REpV,IE�WED�F�ORR�CODE COM UANC 1.1. ALL CONSTRUCTION SHALL BE INSTALLED AS SPECIFIED IN THE MOST CURRENT EDITION OF THE MOA COMPONENT PARTS AND MATERIALS USED NS T 07/11 CONSTRUCTION OF ON—SITE WASTEWATER DISPOSAL SYSTEMS AND AND IN ACCORDANCE WITH AMC 15.65 AND 15.55. 1.2. CONTRACTED WORK WILL BE IN COMPLIANCE WITH MUNICIPALITY OF ANCHORAGE STANDARD SPECIFICATIONS (MASS) DIVISION 10 & DIVISION 20 AS APPROPRIATE. 1.3. SCOPE OF WORK: INSTALL SEPTIC TANK, DRAIN FIELD, AND WELL. 1.4. GROUNDWATER WAS ENCOUNTERED AT A DEPTH OF 7.0 FEET BELOW EXISTING GRADE AS EVIDENCED BY THE SOIL TEST HOLE. 'IF AN APPARENT WATER TABLE IS OBSERVED IN ANY OF THE EXCAVATIONS LESS THAN 7.0 FEET BELOW EXISTING GRADE NOTIFY THE ENGINEER IMMEDIATELY. 1.5. STRUCTURES DEPICTED ON THE SITE PLAN ARE BASED UPON ONE OF THE FOLLOWING: CONCEPTUAL PLOT PLAN DEVELOPED BY OWNER; A PLOT PLAN DEVELOPED BY RLS; OR A SURVEY AS—BUILT. 2. CONSTRUCTION SPECIFICATIONS: 2.1. ALL EXCAVATION DEPTHS ARE ADVISORY. THEY ARE TO BE VERIFIED AND MAY BE MODIFIED BY THE ENGINEER IF ACTUAL FIELD CONDITIONS VARY FROM THOSE USED TO PREPARE THE DESIGN 2.2. EXCAVATE THE DRAIN FIELD. BOTTOM OF EXCAVATION SHALL BE LEVEL AND SCARIFIED. RECORD ELEVATIONS AT BEGINNING, MIDDLE AND END OF TRENCH BOTTOM. CONSTRUCTION EQUIPMENT SHALL NOT OPERATE ON THE FLOOR OF THE EXCAVATION. ANY MATERIAL COMPACTED BY THE OPERATION OF THE CONSTRUCTION EQUIPMENT SHALL BE REMOVED AND REPLACED WITH UNCOMPACTED MATERIAL. 2.3. PLACE THE SEWER ROCK TO THE SPECIFIED DEPTHS. DO NOT CONTAMINATE SEWER ROCK WITH NATIVE MATERIAL OR SPOILS FROM EXCAVATION. LEVEL ROCK SURFACE TO t1" PRIOR TO INSTALLING THE PERFORATED PIPE. 2.4. ALL PIPE SHALL BE PVC CONFORMING TO ASTM D3034 OR ENGINEER APPROVED EQUAL. MINIMUM SOIL COVER SHALL BE 3 FEET OVER THE PIPE AND 4 FEET OVER THE SEPTIC TANK. ONE INCH OF INSULATION MAY BE SUBSTITUTED FOR 1 FOOT OF SOIL COVER. 2.5. ALL INSULATION SHALL BE 2" THICK DOW HI -40 INSULBOARD OR ENGINEER APPROVED EQUAL. CENTER INSULBOARD WIDTH OVER SEPTIC TANK OR LINES. 2.6. GEOTEXTILE SHALL BE MIRAFI 140S OR ENGINEER APPROVED EQUAL. LAP ALL JOINTS 2 FEET MINIMUM. 2,7. COVER THE DISTRIBUTION PIPE WITH A MINIMUM OF 2" OF SEWER ROCK AND COVER WITH GEOTEXTILE BEFORE PLACING INSULATION AND BACKFILL. 2.8. MATERIAL USED AS FILL SHALL BE CLEAN AND FREE OF ORGANICS, TRASH AND CONSTRUCTION DEBRIS. 2.9. SLOPE ALL FILL MATERIAL TO DRAIN AT 2% MINIMUM SLOPE AND 3:1 MAXIMUM SLOPE AND IN SUCH A MANNER THAT PONDING AT OR NEAR THE DRAIN FIELD DOES NOT OCCUR. THE FILL SHALL BE LEFT AT 6" HIGHER THAN SHOWN TO ALLOW FOR SETTLEMENT. SEED SURFACE AFTER COMPLETING INSTALLATION AS PER MOA CODE. 2.10. RECORD THE FINISH GROUND ELEVATION OVER THE BEGINNING, MIDDLE AND END OF SYSTEM. 2.11. MAINTAIN 5' SEPARATION BETWEEN PERCOLATION HOLE AND THE DRAIN FIELD TRENCH. 2.12. EXPOSE, PUMP AND FILL LOG DISPOSAL CRIB OR CONCRETE TANK WITH SOIL TO ABANDON IAW WITH MOA CODE IF NEEDED. 3. CONTRACTOR RESPONSIBILITIES: 3.1. THE CONTRACTOR SHALL FAMILIARIZE THEMSELVES WITH THE SITE CONDITIONS AND LOCATIONS OF ALL LOT LINES, EASEMENTS, WELLS (E & P), SEPTIC SYSTEMS (E & P) AND SHALL MEET MINIMUM SEPARATION DISTANCES OR AS NOTED. 3.2. THE CONTRACTOR (BOTH WELL AND SEPTIC SYSTEM CONTRACTORS) SHALL HAVE ANY WELL LOCATION AND SEPTIC LOCATION STAKED AND ANY LOT LINE AND WELL RADIUS SHOWN ON THE PLAN WITHIN 30 FEET OF THE PROPOSED SYSTEM STAKED BY A REGISTERED LAND SURVEYOR BEFORE STARTING THE WORK. 3.3. THE CONTRACTOR IS RESPONSIBLE FOR ALL R.O.W. AND OTHER REQUIRED PERMITS, OTHER THAN THE ATTACHED. 3.4. THE CONTRACTOR SHALL CALL FOR LOCATING OF ALL BURIED UTILITIES. 3.5. THE CONTRACTOR SHALL PROVIDE 24 HOUR NOTICE TO THE ENGINEER PRIOR TO START OF WORK. ALL SURVEYING AND LOCATES SHALL BE IN PLACE PRIOR TO NOTIFYING THE ENGINEER. 3.6. THE CONTRACTOR SHALL NOTIFY THE ENGINEER OF ANY DISCREPANCY BETWEEN THE APPROVED DRAWINGS AND SITE CONDITIONS/LIMITATIONS POTENTIALLY CAUSING THE NEED TO MODIFY THE DESIGN. 3.7. AT THE COMPLETION OF THE WORK, THE CONTRACTOR SHALL SUBMIT RED—UNE AS—BUILT DRAWINGS TO THE ENGINEER. THE RED—LINES SHALL INCLUDE PIPE LENGTHS, ORIGINAL GROUND ELEVATIONS, PIPE ELEVATIONS, AND TANK ELEVATIONS. 3.8. THE CONTRACTOR SHALL PROVIDE PHOTOGRAPHS OF THE SYSTEM INSTALLATION TO INCLUDE BOTTOM OF EXCAVATION, TOP OF PIPE WITH CLEAN—OUTS AND MONITOR TUBES INSTALLED, INSTALLED TANK AND FINAL GRADING. 4. THE CONTRACTOR SHALL SIGN THE FOLLOWING: I CERTIFY THAT ALL WORK WILL BE PERFORMED IN ACCORDANCE WITH THE APPROVED PERMIT, AND ANY AND ALL CHANGE ORDERS, AND THAT THE AS—BUILT REDLINES ARE TRUE AND ACCURATE REPRESENTATION OF THE PROJECT AS CONSTRUCTED. CONTRACTOR: BY: TITLE: DATE: NOTES: PAMONE ENG SVC, LLC Date FOR CONSTRUCTION P.O. BOX 100217 ANCHORAGE, AK 99510 P•(�i, •.. Scale /2023 PHONE (907) 272-8218 FAX (907) 272-8211 :4931 �* NTS .... .. .. ....... P.I.D. NO CANYON VIEW ESTATES, BLOCK 2, LOT 8 an **me 042-081-43 "even HULTQUIST HOMES INC. PERMIT No. CE 8149 13868 CANYON ROAD osPxxxxxx DESIGN DETAILS ANCHORAGE, AK Sheet 2OF3 1 2 3 4 5 6 7 8 9 10 11 12 13 14 TEST HOLE 2023-8 OR I ORGANICS GRAVELLY SAND WITH SILT SOILS LOG - PERCOLATION TEST WAS GROUND WATER ENCOUNTERED? N IF YES, AT WHAT DEPTH? -DRY DEPTH TO WATER AFTER MONITORING? -8.0' DATE: 5/10/23 DEPTH TO WATER AFTER MONITORING? -7.0' DATE: 5/25/23 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMANC OSP231164, Curtis Towr�n , 07/11, READING DATE CLOCK WATERTIME NET TIME LEVEL NET DROP READING 1 5/3/23 2 3 4 WATER ABSORBED TOO QUICKLY TO ACCURATELY READ 5 6 a 9 10 11 12 PEROLATION RATE <1 (min/inch) PERC HOLE DIAMETER 6 inches TEST RUN BETWEEN 3 FT AND 4 FT " SEE SIEVE ANALYSIS BOH COMMENTS: Test hole excavated by BROWNSON BROTHERS. DATE PERFORMED: 5/3/23 PERFORMED BY: PANNONE ENGINEERING. I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDLINES IN EFFECT ON THE DATE OF THIS TEST. INFILTRATION SECTION SCALE 1"=5' FINISHED GRADE NOTES: 1. SOILS ON THE LOT ARE USDA HSG 'A' SOILS WITH AN ASSUMED INFILTRATION LINE OF 46%. EFFLUENT WITH AN INFILTRATION LINE OF 46% WILL NEVER DAYLIGHT ON A SLOPE OF 33%. 2. SECTION SHOWS FIELD CLOSER TO SLOPE THAN DESIGN LOCATION FOR THE PURPOSE OF DEPICTING THE SLOPE OF INFILTRATION LINE VS THE SLOPE OF THE TERRAIN. NOTES: PANNONE ENG SVC, LLC Date FOR CONSTRUCTION P.O. BOX 102954 ANCHORAGE, AK 99510E 7/10/2023 PHONE (907) 272-8218 FAX (907) 272-8211 �` ••• ••• Scale *'•�� �* NTS •••• ••••••• P.I.D. NO CANYON VIEW ESTATES, BLOCK 2, LOT 8 ••�}ven •. rio�042-081-43 eane HULTQUIST HOMES INC. 8149 PERMIT NO. 13868 CANYON ROAD IOSPxxxxxx SOILS LOG ANCHORAGE, AK •�•,•�••••.Sheet 'mAt� 3 OF 3 040.002 Client: Pannone Engineering Services Project: Canyon View SD Block 2 Date: May 18, 2023 Crowther Associates Particle Size Distribution Table (percent-_p'assi '§"subject sieve size) 1 f{Y Sample Source 7 8 10 Moisture 7.0%, 6.9% % 12.1% ContentR Sieve Size Percent Finer Percent Finer Pe'' ent Finer Percent Finer 3 inch 100 100 P.i 100, 100 ni 1-1/2 inch 100 100 100; 100 3/4 inch 96 r 91 92 `' 100 #4 58 tk 56 57 R, 93 #10 38 66 37 82 #40 14 A19 15 24 #100 7 12 10 10 LY` yJy} Sj #200 6 11 9 7 0.02 mm xx �; xx xx A xx Classification Gravelly Sar Gravelly Sand Grave'lly Sand Sand with Silt with Silt with Silt with hilt (SP -SM) (SP -SM) -SM) (SPSM) Invoice 192 1632 Bellevue Circle /Anchorage, Alaska 99515 Telephone (907) 349-2198 /E mail: ct•owther@alaska.net MUHMPAUTY OF ° HCHOR UGC 0 Development Services Department - ' Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Parcel I.D. 042-081-43 Certificate of On -Site Systems Approval Expiration Date: �� Z J Legal description CANYON VIEW ESTATES BLK 2 LT 8 Site address 13868 CANYON RD Anchorage AK Current property owner(s) HULTQUIST HOMES INC X The On -site system(s) is/are approved for 3 bedrooms Conditional approval for bedrooms, with the following stipulations: Comments or advisories: Original Certificate Date: 3/21 /2024 This Certificate of On -Site Systems Approval (COSA) is intended to demonstrate the subject system(s) is/are in substantial compliance with municipal code. The Municipality of Anchorage, Development Services Department (DSD) issues COSAs based upon representations provided by an independent professional engineer. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. ATTACHMENTS: COSA Checklist X Well Flow Advisory Absorption Field Advisory Nitrate Advisory Tank Age Advisory Arsenic Advisory Other COSA Approvaijune 2022 MUMCPAM_ff V OF ,NCH u R ,\ G ,= Development Services Department `` _= Phone: 907-343-7904 On -Site Water & Wastewater Section Fax. 907-343-7997 14,Certificate of On -Site Systems Approval Application 1. GENERAL INFORMATION Parcel I.D. 042-081-43 Complete legal description Canyon View Estates Block 2 Lot 8 Location (site address) 13868 Canyon Road Current property owner(s) HultgUlst Homes, Inc 2. ON -SITE SYSTEMS SIZED FOR 3 BEDROOMS Day phone 3. TYPE OF WATER SUPPLY: 0 Private Well ❑ Private Well serving 2 dwelling units ❑ Private Well serving 3+ dwelling units ❑ Community Well or Public ❑ Water Storage 4. TYPE OF WASTEWATER DISPOSAL: * Private Septic ❑ Private Septic serving 2 dwelling units ❑ Holding Tank ❑ Community Septic or Public Sewer 5. SEPTIC TANK: ❑ Steel ❑® Plastic ❑ Concrete ❑ Fiberglass Age < 1 - See advisory if steel older than 20 years 6. ABSORPTION FIELD: ❑ AWWTS ❑ Bed ❑ Deep Trench ❑® Wide Trench ❑ Seepage Pit Waiver request for: Expedited review requested: ❑ Distance: By applying for this entitlement, this property is subject to inspection by municipal On -site staff to verify the accuracy of the information provided. COSA Fee $ Z� Date of Payment COSA # �� GZ`%'l b Waiver Fee $ Date of Payment Waiver # COSA Application —June 2022 COSA Checklist_June 2022 COSA Checklist Legal Description: Parcel ID: If more than 1 well and/or septic system on lot, provide separate checklist. Structure served by this system ____ A. WELL DATA Well log is filed with Onsite (or attached) Date drilled Total depth ft Cased to ft Sanitary seal is functioning correctly Wires are properly protected Casing height (above ground) in. Date of flow test for COSA Static water level at beginning of test ft. Well production at time of test gpm Water storage tank volume gallons Well disinfected for coliform test? Yes No Coliform bacteria is Negative Nitrate mg/L Nitrate less than MRL (ND) Arsenic ug/L Arsenic less than MRL (ND) Collected by Date Comments __________________________________________________________________________________ B. TANK DATA Measured operating fluid level in septic tank Date of pumping Required maintenance completed, if AWWTS Comments: C. LIFT STATION Required maintenance completed Age of lift station years Lift station material Comments: D. ABSORPTION FIELD DATA Which system tested (date installed) ALL standpipes present per record drawing Total measured depth from grade ft (max) Measured depth to pipe invert from grade ft (min) N/A – pressurized field. Per record drawings, field is insulated. Monitor tubes go to bottom of effective. If not, state depth into effective Presoaked required if (Required if house vacant or field not used for more than 30 days prior to date of test) Gallons introduced gallons date Any rejuvenation treatment (past 12 months) If yes, enter date Adequacy test date Results Pass Fluid depth prior to test in Water added gal New fluid depth in Elapsed time min Final fluid depth in Absorption rate gpd FIELD STATUS – POST RECOVERY Effective depth (per record drawings) in Effective depth used in Effective depth remaining in Comments/Deficiencies: COSA Checklist_June 2022 E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well on lot) Septic Tank/Lift Station on Lot > 100’ Yes if No ft Neighboring Tank > 100’ Yes if No ft Absorption Field on Lot > 100’ Yes if No ft Neighboring Absorption Fields > 100’ Yes if No ft Community Sewer Main > 75’ Yes if No ft Community Sewer Manhole/Cleanout > 100’ Yes if No ft Private Sewer/Septic Line > 25’ Yes if No ft Holding Tank > 100’ Yes if No ft Animal Containment > 50’ Yes if No ft Manure/Animal Excreta Storage > 100’ Yes if No ft N/A – Served by Community Well (not on lot) or Public Water From Septic/Holding Tank and Absorption Field(s) on Lot to: (Please enter distances if less than required) Building Foundations > 10’ Yes if No ft Tank to Property Line > 5’ Yes if No ft Field to Property Line > 10’ Yes if No ft Water Main > 10’ Yes if No ft Water Service Line > 10’ Yes if No ft Surface Water > 100’ Yes if No ft Wells on Adjacent Lots: Private Wells > 100’ Yes if No ft Community Wells > 200’ Yes if No ft If tank or field is under driveway comment below F.ENGINEER’S COMMENTS G.CERTIFICATION & STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines, indicates that the on-site water supply and/or wastewater disposal system appears to comply with applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation, unless noted otherwise. Name of Firm Phone Engineer’s Printed Name Date 2024.03.18