Loading...
HomeMy WebLinkAboutSPRUCE TERRACES LT 22 SPRUCE TERRACES Lot 22 #020-044-27 Municipality of Anchorage On -Site Water and Wastewater Section - (907) 343-7904 Page 1 of 1 ON -SITE WASTEWATER INSPECTION REPORT Permit Number: OSP231274 PID Number: 020-044-27 Dwelling: X Single Family (SF) El with ADU M Duplex (D) n Two Single Family Project: On New n Upgrade Name Spinell Homes Inc. ABSORPTION FIELD nE Deep Trench n Wide Trench n Bed n Mound Site Address 6881 Avalanche Circle 0 Other Phone Number of Bedrooms Soil Rating Total depth from original grade 5 1.2 GPD/SFI 10.0 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade 4.0 Ft. Gravel depth beneath pipe 6.0 Ft. Subdivision Block Lot Spruce Terraces 22 Fill added above original grade 1.8 Ft. Gravel length 55 Ft. Township Range Section Gravel width 2.5 Ft. Beds: Number of Lines n/a Distance between lines n/a Ft. SEPARATION DISTANCES To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist, between trenches From Tank Field Tank Line 660 Ft2 1 n/a Ft. Well 100'+ 100'+ NA NA 25'+ TANK 9 Septic E] S.T.E.P. [I Holding 0 Other Manufacturer Greer Capacity 1500 Gal. Surface Water 100'+ 100'+ NA NA Material HDPE Number of compartments 2 Lot Line 101+ 10'+ NA NA NA Foundation 10'+ 10+ NA NA LIFT STATIONManufacturer Capacity Gal. Remarks Alarm location Electrical installed by PIPE MATERIAL House to tank 3034 Tank to 3034 fi draineld Installer — Pomraning Excavation, LLC Drainfield 3034 CO/MT 3034 Inspector PES BENCH MARK (Assumed elevation) 100.0 ft Inspection vt 10/02/23 nd 10/27/23 Location and description dates: 3rd 10/27/23 2 41h 11/03/23 Door threshold see record drawing 1 ON -SITE WATER AND WASTEWATER SECTION APPROVAL Engineer's Stamp 0 At Conditional Approval: Date H 49 TH A... ........ . . . . . . )Leven )anr'tone Septic System CL (81 ,icl) , ";we Approved A Date ltklzo?,� -I...n.... Note: this approval does not include well permit requirements. (Rev 05/02/18) PA N N O N E E N G S V C , L L C ( C . I . 1 0 8 8 ) PROFILE SCALE: NTS 1500 GALLON POLY TANK SLOPE SECTION SCALE: NTS PA N N O N E E N G S V C , L L C ( C . I . 1 0 8 8 ) PA N N O N E E N G S V C , L L C ( C . I . 1 0 8 8 ) COMMENTS: Test hole excavated by POMRANING EXCAVATION. PERFORMED BY: PANNONE ENGINEERING SERVICES, LLC. I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDLINES IN EFFECT ON THE DATE OF THIS TEST. ·<1.0 (min/inch) ·6" ·4 FT AND 5 FT · SOILS LOG & PERCOLATION TEST 040.002 Crowther Associates 1632 Bellevue Circle / Anchorage, Alaska 99515 Telephone (907) 349-2198 / E mail: 907crowther@gmail.com Date:October 23, 2023 Client:Pannone Engineering Services, Dan Project:Spruce Terrace Lot 22 Particle Size Distribution Table (percent passing subject sieve size) Sample Source -- Moisture Content 6.7% Sieve Size Percent Finer Percent Finer Percent Finer Percent Finer 3 inch 100 1-1/2 inch 100 ¾ inch 85 #4 63 #10 53 #40 28 #100 18 #200 17 0.02 mm xx Classification Silty Gravelly Sand (SM) Invoice 213 As Built Feet 0 60 120 MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Wastewater Disposal System Permit Permit Number: OSP231274 Work Type: Septic Initial Tax Code Number: 02004427000 Site Legal Address: Site Mailing Address: 6881 AVALANCHE CIR, Anchorage Owner: SPINELL HOMES INC Design Engineer: PANNONE ENGINEERING SERVICES This permit is for the construction of: Q Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy U � ti fi .� - 1)elrirtment Effective Date: 8/22/2023 Expiration Date: 8/21/2024 S' P),2- v cr- %E r -v_ 4c_r__j- L 2 2 Lot Size in Sq Ft: 56059 Total Bedrooms: 5 ❑ Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Received By: I S S�`z 7.0 Iters Date: Issued By: L Date: li 22 rim L I�1l�1UH0C�P Ld TY OF HCX0RAGr s Community Development Department Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On -Site Water & Wastewater Program ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 020-044-27 Property owner(s) Spinell Homes Inc Day phone Mailing address 1900 W. Northern Lights Blvd #200 Anchorage, AK Site address NHN Avalanche Circle Legal description (Sub'd., Block & Lot) Spruce Terrace L22 Legal description (Township, Range & Section) Lot Size 56,059 Sq. Ft. Number of Bedrooms 5 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (N all that apply) Absorption Field ❑X Initial ❑X Single Family (SF) ❑X ADU) Septic Tank FX]Upgrade El(w/wo (D) EJ Holding Tank ElRenewal ElDuplex Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. IsT_"�T> (Signature of property owner or authorized agent) Permit/Rush Fees: 5 Z- Waiver Fees: Date of Payment: Receipt Number: Permit No. Permit App_'- ; . -..:c Date of Payment: Receipt Number: Waiver No. Pannone Engineering Services LLC Steven R. Pannone, Principal Registered Professional Engineer E-mail: steve@panengak.com Mailing: P.O.Box 1807, Palmer, AK 99645 Telephone: (907) 745-8200 FAX: (907) 745-8201 21 August 2023 Municipality of Anchorage Development Services Department On-Site Water & Wastewater Program 4700 Elmore Road Anchorage, Alaska 99519 Subject: Spruce Terrace L22 Septic System Permit Request This is a design narrative for a permit to install a septic system upgrade on the subject property. The proposed system will serve a proposed five-bedroom (5) house. This lot and surrounding lots are to be served by a community water system. 1. Soils: A test hole was performed on this lot by Pannone Engineering Services, LLC on 10/15/2020. Groundwater was not observed during the excavation of the test hole, and bedrock was not encountered. No groundwater was observed in the test hole monitor tube after 7-days (10/27/2020). Based on the results of the percolation test and overall soils appearance an application rate of 1.2 gpd/SF was used for the design of a conventional wastewater treatment system in the area of the test hole. 2. Soil Absorption System Design. a. See Sheet 1 of the design package. 3. Surface Water: There is no surface water within 100 feet of the proposed septic tank and drain field. 4. Topography: See attached site plan for area topography. There are slopes exceeding 25% less than 50ft from the proposed drain field. The proposed installation conforms to the steep slope provisions of AMC 15.65. 5. Drawing Markings: The Drawings are marked “For MOA Review Only”. When written notification that the review is complete and no further comments are received from MoA On-Site Department, the note will be removed and “For Construction” drawings will be issued. The proposed installation will not affect the future development of this or the surrounding lots. If you have any questions or concerns, please contact me at (907) 745-8200. Sincerely, SRP Steven R. Pannone, P.E. F. ASCE Owner/Civil Engineer Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP231274, Curtis Townsend, 08/22/23 PA N N O N E E N G S V C , L L C ( C . I . 1 0 8 8 ) Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP231274, Curtis Townsend, 08/22/23 PA N N O N E E N G S V C , L L C ( C . I . 1 0 8 8 ) 1 SCALE: 1"=10' DRAIN FIELD SLOPE SECTION Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP231274, Curtis Townsend, 08/22/23 PA N N O N E E N G S V C , L L C ( C . I . 1 0 8 8 ) COMMENTS: Test hole excavated by POMRANING EXCAVATION. PERFORMED BY: Pannone Engineering Services. I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDLINES IN EFFECT ON THE DATE OF THIS TEST. SOILS LOG INSTALL NEW 1500-gallon SEPTIC TANK, AND SOIL ABSORPTION SYSTEM. 16 FEET 16 FEET ·1.7 (min/inch) ·6" ·3 FT AND 4 FT Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP231274, Curtis Townsend, 08/22/23 Certificate of On -Site Systems Approval Parcel I.D. 020-044-27 Legal description SPRUCE TERRACES LOT 22 Site address 6881 AVALANCHE CIR Current property owner(s) SPINELL HOMES INC Expiration Date: 2- X The On -site system(s) is/are approved for 5 bedrooms Conditional approval for bedrooms, with the following stipulations: Comments or advisories: Original Certificate Date: 11 /5/2024 This Certificate of On -Site Systems Approval (COSA) is intended to demonstrate the subject system(s) is/are in substantial compliance with municipal code. The Municipality of Anchorage, Development Services Department (DSD) issues COSAs based upon representations provided by an independent professional engineer. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. ATTACHMENTS: COSA Checklist X Well Flow Advisory Absorption Field Advisory Nitrate Advisory Tank Age Advisory Arsenic Advisory Other COSA ApprovMjune 2022 Certificate of On -Site Systems Approval Application 1. GENERAL INFORMATION Parcel I.D. 020-044-27 Complete legal description Spruce Terraces L22 Location (site address) 6881 Avalanche Circle Current property owner(s) Spinell Homes Inc 2. ON -SITE SYSTEMS SIZED FOR 5 BEDROOMS Day phone 3. TYPE OF WATER SUPPLY: ❑ Private Well ❑ Private Well serving 2 dwelling units ❑ Private Well serving 3+ dwelling units FW Community Well or Public ❑ Water Storage 4. TYPE OF WASTEWATER DISPOSAL: 0 Private Septic ❑ Private Septic serving 2 dwelling units ❑ Holding Tank ❑ Community Septic or Public Sewer 6. SEPTIC TANK: ❑ Steel FNJ Plastic ❑ Concrete ❑ Fiberglass Age new - See advisory if steel older than 20 years 6. ABSORPTION FIELD: ❑ AWWTS ❑ Bed ❑■ Deep Trench ❑ Wide Trench ❑ Seepage Pit Waiver request for: Expedited review requested: ❑ Distance: By applying for this entitlement, this property is subject to inspection by municipal On -site staff to verify the accuracy of the information provided. COSA Fee $ Date of Payment 12 2 cr COSA# Waiver Fee $ Date of Payment Waiver # COSA Application_June 2022 COSA Checklist_June 2022 COSA Checklist Legal Description: Parcel ID: If more than 1 well and/or septic system on lot, provide separate checklist. Structure served by this system ____ A. WELL DATA Well log is filed with Onsite (or attached) Date drilled Total depth ft Cased to ft Sanitary seal is functioning correctly Wires are properly protected Casing height (above ground) in. Date of flow test for COSA Static water level at beginning of test ft. Well production at time of test gpm Water storage tank volume gallons Well disinfected for coliform test? Yes No Coliform bacteria is Negative Nitrate mg/L Nitrate less than MRL (ND) Arsenic ug/L Arsenic less than MRL (ND) Collected by Date Comments __________________________________________________________________________________ B. TANK DATA Measured operating fluid level in septic tank Date of pumping Required maintenance completed, if AWWTS Comments: C. LIFT STATION Required maintenance completed Age of lift station years Lift station material Comments: D. ABSORPTION FIELD DATA Which system tested (date installed) ALL standpipes present per record drawing Total measured depth from grade ft (max) Measured depth to pipe invert from grade ft (min) N/A – pressurized field. Per record drawings, field is insulated. Monitor tubes go to bottom of effective. If not, state depth into effective Presoaked required if (Required if house vacant or field not used for more than 30 days prior to date of test) Gallons introduced gallons date Any rejuvenation treatment (past 12 months) If yes, enter date Adequacy test date Results Pass Fluid depth prior to test in Water added gal New fluid depth in Elapsed time min Final fluid depth in Absorption rate gpd FIELD STATUS – POST RECOVERY Effective depth (per record drawings) in Effective depth used in Effective depth remaining in Comments/Deficiencies: COSA Checklist_June 2022 E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well on lot) Septic Tank/Lift Station on Lot > 100’ Yes if No ft Neighboring Tank > 100’ Yes if No ft Absorption Field on Lot > 100’ Yes if No ft Neighboring Absorption Fields > 100’ Yes if No ft Community Sewer Main > 75’ Yes if No ft Community Sewer Manhole/Cleanout > 100’ Yes if No ft Private Sewer/Septic Line > 25’ Yes if No ft Holding Tank > 100’ Yes if No ft Animal Containment > 50’ Yes if No ft Manure/Animal Excreta Storage > 100’ Yes if No ft N/A – Served by Community Well (not on lot) or Public Water From Septic/Holding Tank and Absorption Field(s) on Lot to: (Please enter distances if less than required) Building Foundations > 10’ Yes if No ft Tank to Property Line > 5’ Yes if No ft Field to Property Line > 10’ Yes if No ft Water Main > 10’ Yes if No ft Water Service Line > 10’ Yes if No ft Surface Water > 100’ Yes if No ft Wells on Adjacent Lots: Private Wells > 100’ Yes if No ft Community Wells > 200’ Yes if No ft If tank or field is under driveway comment below F.ENGINEER’S COMMENTS G.CERTIFICATION & STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines, indicates that the on-site water supply and/or wastewater disposal system appears to comply with applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation, unless noted otherwise. In conducting an adequacy test, I attempt to provide a thorough, conscientious engineering analysis of the system in accordance with ADEC & MOA guidelines and regulations. The reported results describe the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soil condition, ground water levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of this system. All systems eventually fail, and satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. Therefore, we cannot provide any warranty for future performance, nor can we estimate remaining life of the system. The content of this report is for the sole benefit of the owner listed above. Name of Firm Phone Engineer’s Printed Name Date 10/17/2024 10/17/2024