HomeMy WebLinkAboutLAKEWOOD HILLS #2 LT 24AMv r�-
o t
MUNICIPALITY OF ANCHORAGE
Development Services Department Phone: 907-343-7904
On-Site Water & Wastewater Section Fax: 907-343-7997
Pump Installation Log
Well Drilling Permit Number: _______________ Date of Issue: ____-____-____
Parcel Identification Number: ____-____-____
Legal Description Block Lot Property Owner Name & Address:
Pump Installation Date: _____-_____-_____
Pump Intake Depth Below Top of Well Casing: __________ feet
Pump Manufacturer’s Name: ___________________________
Pump Model: _____________________________________
Pump Size: ____________hp
Pitless Adapter Burial Depth: _________ feet
Pitless Adapter Manufacturer’s Name: _________________________
Pitless Adapter Installer: ____________________________
Well Disinfected Upon Completion? Yes No
Method of Disinfection: _____________________________
Comments:
Pump Installer Name: __________________________________
Company: ___________________________________________
Mailing Address: ______________________________________
City: ___________________ State: __________Zip: _________
Attention: The pump installer shall provide a pump installation log to On-site within 30 days of pump installation.
Municipality of Anchorage
On-Site Water and Wastewater Section • (907) 343-7904 Page 1 of 3
ON-SITE WASTEWATER INSPECTION REPORT
Permit Number: OSP231237 PID Number: 015-135-19
Dwelling:❑ Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: X New ❑ Upgrade
Name
Bradley Company LTD LLC
ABSORPTION FIELD
Q Deep Trench [I Wide Trench E] Bed E] Mound
Site Address
10581 Hillside Dr
❑ Other
Phone
(907) 345-8153
Number of Bedrooms
5
Soil Rating
1.2
Total depth from original grade
10.7
GPD/SF
Ft.
LEGAL DESCRIPTION
Depth to pipe invert from original grade
2.7 Ft.
Gravel depth beneath pipe
8.0 Ft.
Subdivision Block Lot
Lakewood Hills #2 24A
Fill added above original grade
0.0 Ft.
Gravel length
40 Ft.
Township Range Section
Gravel width
3.0 Ft.
Beds: Number of Lines
N/A
Distance between lines
N/A Ft.
SEPARATION
DISTANCES
To
Septic
Absorption
Lift Station
Holding
Sewer
Total absorption area
Number of trenches
Dist. between trenches
From
Tank
Field
Tank
Line
640 Ftz
1
N/A Ft.
Well
>100'
>100'
N/A
N/A
>25
TANK 0 Septic ❑ S.T.E.P. ❑ Holding ❑ Other
Manufacturer Capacity
Greer 1500 Gal.
Surface Water
>100'
>100'
N/A
N/A
Material
Plastic
Number of compartments
2
Lot Line
>5
>10'
N/A
N/A
NA
Foundation
r>1 '
> 10'
N/A
N/A
L ATION
Manufacturer
Capacity
Remarks Tank rated for 10' burial
Gal.
Alarm location
Electric ailed by
Installer
PIPE MATERIAL House to tank D3034 drainfield Tank to
D3034
Whitters Excavating
Drainfield D3034 CO/MTD3034
Inspector Ben Schiller
BENCH MARK (Assumed elevation) 100 ft
Inspdection 1-8/20/24 8/20/24
Location and description
2nd
Bottom siding NE corner
3rd 4th
ON-SITE WATER AND WASTEWATER SECTION APPROVAL
Engineer's Stamp
Conditional Approval: Date
*: �sTH ,* r
r -x r:::}....
Benjarnl naSchiller : Ir
�� �.�6, CE 12592 k`��/�
—
Septic Syste
� `
/, � -
Approved Dat c r
.
�� ASC_ P6/16/26
tl
�orl ss�oN4...
N :this approval does not include well permit requirements.
trtev u5iu7
PROFILE AS-BUILT
(NO SCALE)
94.2
88.5
94.8
97.5
FC
O
MH
SV
PERMIT # 0SP231237 PID # 015-135-19
LAKEWOOD HILLS #2, LOT 24A
1500 GAL
SEPTIC TANK
96.9 ORIGINAL & FINISH GRADE
40'
DRAINFIELD ROCK
MT
2
TH
#
2
NO GROUNDWATER 8/2/24
86.2
94.2
CO
2
CO
1
78.9
86.2
94.2
MT
1
2C
O
94.0
Benjamin Schiller
CE 12592
R
E
GISTEREDPROFE S S I O N A L E N GINEER
6/16/26
2" INSULATION
2" INSULATION
ALTERNATE SITE
CAT III SYSTEM
5-WIDE TRENCH, 30' LONG,
0.5' E.D.
Benjamin Schiller
CE 12592R
E
GISTEREDPROFE S S I O N A L E N GINEER
1"=50'
40' LONG x 3' WIDE, 8' EFFECTIVE
DEPTH ABSORPTION TRENCH
1500-GAL
SEPTIC TANK
CO - CLEANOUT
2CO - DOUBLE CLEANOUT
FCO - FOUNDATION CLEANOUT
FS - FLOW SPLITTER VALVE
MH - MANHOLE
MT - MONITORING TUBE
SV - SEPTIC VENT
TH - TEST HOLE
LEGEND
2CO
TH#1
PERMIT # OSP231237 PID # 015-135-19
LAKEWOOD HILLS #2, LOT 24A
A
B
FEET
0 50 100
HI
L
L
S
I
D
E
D
R
I
V
E
5-B
D
R
M
H
O
M
E
790
PLAN AS-BUILT
6/16/26
800
830
820
810
CO2
CO1
FCO
MT2
MT1
NEIGHBORING SEPTIC SYSTEM
NEIGHBORING SEPTIC AREA
TH#2
WELLS > 100' FROM PROPERTY LINE
FOR LOTS 6 AND 7
MHSV
EXISTING WELL
A B
FCO
MH 23.7
SV 26.3
2CO 28.3
CO1 28.4
MT1 26.8
CO2 44.3
13.4
22.7
26.5
29.0
48.3
43.6
30.1
MT2 38.129.0
MUNICIPALITY OF ANCHORAGE
Development Services Department Phone: 907-343-7904
On-Site Water & Wastewater Section Fax: 907-343-7997
Well Log
Permit Number: #__________ Date of Issue: ________ Parcel Identification Number: __________________
Date Started: _________ Date Completed: _________ Is well located at approved permit location? Yes No
Legal Description:_________________________________________________________________________
Property Owner Name & Address: _______________________________________
_______________________________________
_______________________________________
Borehole Data: Depth (ft)
Soil Type, Thickness & Water Strata From To
Method of Drilling air rotary cable tool
Casing type: _________
Wall Thickness: inches
Diameter: inches Depth: feet
Liner Type: _________
Diameter: inches Depth: feet
Casing stickup above ground: feet
Static water level (from ground level): feet
Pumping level: feet after
hours pumping gpm
Recovery Rate: gpm
Method of Testing: _________
Well Intake Opening Type:
Open End Open Hole
Screened Start feet Stopped feet
Perforations Start feet Stopped feet
Grout Type: _________ Volume: _________
Depth: _________ Start feet Stopped feet
Well Disinfected Upon Completion? Yes No
Method of Disinfection: Comments:
Well Driller: _____________________________
Company: _____________________________
Mailing Address: _____________________________
Water Sample Results:
Arsenic: _________ ug/L
Nitrates: _________ mg/L
Total Coliform Bacteria:_________ colonies/100mL
Attention: The well driller shall provide a well log to the
On-site Water and Wastewater Section within 30 days of
completion.
MUNICIPALITY OF ANCHORAGE
On -Site Water & Wastewater Program
PO Box 196650 4700 Elmore Road
Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997
http://www.muni.org/onsite
On -Site Water & Wastewater System Permit
Permit Number: OSP231237
Work Type: WellSeptic Initial
Tax Code Number: 01513519000
Site Legal Address: LAKEWOOD HILLS #2 LT 24A G:2540
Site Mailing Address: 10581 Hillside DR, Anchorage
Owner: BRADLEY COMPANY LTD LLC
Design Engineer: FORGE ENG
This permit is for the construction of:
Effective Date:
Expiration Date:
Lot Size in Sq Ft:
Total Bedrooms:
,�plcnt
\0
Dellartill ell t
8/24/2023
8/23/2024
46200
Q Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy Q Private Well ❑ Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
CQ L®C��iorn Sz /q 1
19
RMEIVLRI y; T_.SScte
Issued By:
Date:
Date:
5
MUNICIPALITY OF ANCHORAGE
Community Development Department Phone: 907-343-7904
Development Services Division Fax: 907-343-7997
On -Site Water & Wastewater Program
ON-SITE SEWER/WELL PERMIT APPLICATION
Parcel I.D. 015-135-19
Property owner(s) Bob Bradley
Mailing address P.O. Box 110226, Anchorage, AK 99511
Site address 10581 Hillside Drive, Anchorage, AK 99507
Day phone (907) 345-8153
Legal description (Sub'd., Block & Lot) Lakewood Hills #2, Lot 24A
Legal description (Township, Range & Section)
Lot Size 46,200 Sq. Ft. Number of Bedrooms 5
APPLICATION IS FOR:
APPLICATION IS AN:
TYPE OF DWELLING:
(® all that apply)
Absorption Field
❑X
Initial ❑X
Single Family (SF) ❑X
(w/wo ADU)
Septic Tank
❑X
Upgrade
pg ❑
Duplex (D) ❑
Holding Tank
❑
Renewal ❑
Multiple Dwellings ❑
Privy
❑
(SF and/or D)
Private Well
❑X
Water Storage
❑
THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit/Rush Fees: RZ IJ
Date of Payment: B�Z�Z3
Receipt Number: O / y 310
Permit No. 05.p,? -3
�-
Permit App__'- :- ._..:c
Waiver Fees:
Date of Payment:
Receipt Number:
Waiver No.
August 23, 2023
MOA Development Services, On-Site Water & Wastewater Program
4700 Elmore Rd
Anchorage, AK 99507
Subject: Lakewood Hills #2, Lot 24A - 10581 Hillside Dr
Septic system design
Dear On-Site Services Engineer:
The owner of the above lot intends to build a 5-bedroom home on the property, so we are
submitting this permit application for the construction of a new well and septic system. The
attached site plan identifies the location of the home as well as the proposed well, septic location
and alternate site.
The ground surface on the lot slopes moderately down at the front of the lot, but is flatter in the
area of the home and septic location. There are no slopes greater than 25% within 20 feet
downslope of either the primary or alternate site. There is a short slope within 50’ of the primary
site that drops greater than 25% and less than 46%, but that slope drops less than 10’ and meets
the Steep Slopes criteria of muni code. Contours are shown on the site plan showing the grade and
direction of flow. Stormwater drainage will not impact this septic system. The new trench wil l be
constructed parallel to the slope as much as possible.
Wells on this and adjacent lots are shown. No conflicts exist between this proposed system and
any other well or septic system, whether on this lot or adjacent lots. The new system will be a
minimum of 100’ from all wells and surface water, and more than 5’ away from the septic tank.
The alternate site is located more than 6’ away.
Please refer to the attached test hole logs, plan and profile pages for the septic design. If this design
is followed, there will be no adverse impacts to adjacent properties.
Sincerely,
Benjamin Schiller, PE
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP231237, Deb Wockenfuss, 08/24/23
LAKEWOOD HILLS #2, LOT 24A L��
GE
ENGINEERING -.
A:40.lit
r TM *+rl
Benja i Schiller -2592
mw
/
7128123
Aw
PROFESSIONa�,r�-
SEPTIC PLAN
1 50 100
ilm FEET
111=50'
LEGEND
CO -CLEANOUT
2CO - DOUBLE CLEANOUT
FCO - FOUNDATION CLEANOUT
FS - FLOW SPLITTER VALVE
MH - MANHOLE
MT - MONITORING TUBE
SV - SEPTIC VENT
TH - TEST HOLE
I
i
i
I
LOT 2
r
}
I
WELLS > 100' FROM PROPERTY LINE
I
FOR LOTS 6 AND 7
40' LONG x T WIDE, 8' EFFECTIVE
DEPTH ABSORPTION TRENCH
HAMFTONI
NILS
I
MT
L.
C0
TH#'o _ _ , -- Co i 0TH#2
2CO
w
g
FCO
1500 -GAL
ALTERNATE SITE
SEPTIC TAN
CAT III SYSTEM
m
5 -WIDE TRENCH, 30' LONG, 0.5' E.D.
L6
LOT 24A
II
NEIGHBORING SEPTIC SYSTEM
W
-
I
NEIGHBORING SEPTIC AREA
GE
ENGINEERING -.
A:40.lit
r TM *+rl
Benja i Schiller -2592
mw
/
7128123
Aw
PROFESSIONa�,r�-
SEPTIC PLAN
1 50 100
ilm FEET
111=50'
LEGEND
CO -CLEANOUT
2CO - DOUBLE CLEANOUT
FCO - FOUNDATION CLEANOUT
FS - FLOW SPLITTER VALVE
MH - MANHOLE
MT - MONITORING TUBE
SV - SEPTIC VENT
TH - TEST HOLE
LAKEWOOD HILLS #2, LOT 24A LLOl
DESIGN FACTORS: SYSTEM REQUIREMENTS:
750 GPD PEAK FLOW DEEP TRENCH SYSTEM
PERK RATE: 3.7 MIN/IN 1500 -GAL SEPTIC TANK
APPLICATION RATE: 1.2 GPD/SF
750 GPD / 1.2 GPD/SF / (8' DEEP - 2 WALLS) = 39.1 LF TRENCH REQUIRED (40 LF SPECIFIED)
BOTTOM OF TRENCH: 12' BELOW GRADE
FLOW LINE ELEVATION: 4' BELOW GRADE
ADD ADDITIONAL
SOIL TO ENSURE
MINIMUM COVER
AFTER SETTLEMENT
:-:OTEXTILE FABRIC
PERFORATED PVC
OLES DOWN)
RAINFIELD ROCK
TYPICAL TRENCH SECTION
NOTES: (NO SCALE)
1. GRADE AREA OVER TRENCH TO DRAIN AWAY
2. PROVIDE SOF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2'
WITH 2" OF INSULATION
3. CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER
THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY
- �-" q. - I
*� - N
9t l
.......... ..........
Benja •
' Schiller
CE 12592
U28123
LEGAL DESCRIPTION:
PERFORMED FOR:
DATE: PARCEL ID#:
SOILS LOG AND PERCOLATION TEST
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
DEPTH
(feet)
TEST HOLE 1
DATE READING START TIME NET TIME
(minutes)
DEPTH to
WATER NET DROP
PERCOLATION RATE: (MIN/INCH)
(inches)(inches)
DATE OF MONITORING
WAS WATER ENCOUNTERED?
DEPTH TO WATER AFTER MONITORING
IF YES @ WHAT DEPTH?
1.7
7/12 1
2
3
4
5
6
GM (SILTY SANDY GRAVEL)
Professional Engineers Stamp:
NO
Lakewood Hills #2 Lot 24A
7/12/2023 015-135-19
Bob Bradley
3:00 3 0
16
1' OB
4:57
Benjamin Schiller
CE 12592REGISTEREDPROFESSION A L E N GINEER
PERC TEST LOCATION
TECHNICIAN: M. Jakubisin
9 0
16
-
-
7/19/23
COMMENTS:
SITE PLAN
6 0 16
USCS SOIL CLASSIFICATION WAS VISUALLY DETERMINED
7/20/23
3 0
167:26 9 0
16 6 0 16
3 0
169:00 9 0
16 6 0 16
3 0
1610:00 8 15
16 5 15 16
3 0
1610:00 8 15
16 5 15 16
3 0
169:35 9 0
16 6 0 16
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP231237, Deb Wockenfuss, 08/24/23
DEPTH
(feet)
1-
2-
3-
4-
5-
6-
7-
8-
9-
10
11
12
13
14
15
16
17
18
19
SOILS LOG AND PERCOLATION TEST
E N G I N E E R I N G
LEGAL DESCRIPTION: LAKEWOOD HILLS #2 LOT 24A
PERFORMED FOR: BOB BRADLEY
DATE: 7/26/2024 PARCEL ID#: 015-135-19
ZEST HOLE 2
GM (SILTY SANDY GRAVEL)
NO WAS WATER ENCOUNTERED?
- IF YES @ WHAT DEPTH?
NONE DEPTH TO WATER AFTER MONITORING
8/2/24 DATE OF MONITORING
DATE
READING
START TIME
NET TIME
(MINUTES)
DEPTH TO
WATER
(INCHES)
NET DROP
(INCHES)
8/2
1
10:21
30
1 10
7 �0
6 %6
2
10
1 0
4 �6
3 %6
3
10
1-1
3is
2106
4
10
1 16
3136
2 %6
5
10
1 is
3 6
2 %6
6
10
1 0
3 i
2 12Y16
7
10
1 16
316
2 1Y6
PERCOLATION RATE: 3.7 (MIN/INCH)
COMMENTS: USCS SOIL CLASSIFICATION WAS VISUALLY DETERMINED
SITE PLAN
TECHNICIAN: J. OPHEIM
MUNICIPALITY OF ANCHORAGE
Development Services Department Phone: (907)343-7904
On -Site Water & Wastewater Section Fax: (907)343-7997
Certificate of On -Site Systems Approval
OSC261205
Parcel ID 015 -135-19 Expiration Date
Legal description LAKEWOOD HILLS #2 LT 24A
Site address 10581 HILLSIDE DR
Current property owner(s) DIAZ SALVADOR P
X The On-site system(s) is/are approved for 5 bedrooms
Conditional approval for
Comments or conditions:
By: r%
5/28/2027
bedrooms, with the following stipulations:
Original Certificate Date:
6/24/2026
This Cerfificate of On -Site Systems Approval (COSA) is intended to demonstrate the subject
system(s) is/are in substantial compliance with municipal code. The Municipality of Anchorage,
development Service Department (DSD) issues COSAs based upon representations provided by an
independent professional engineer. The Municipality of Anchorage is not responsible for errors or
omissions in the professional engineer's submittal.
ATTACHMENTS:
COSA Checklist X Well Flow Advisory
Absorption Field Advisory Nitrate Advisory
Tank Age Advisory Arsenic Advisory
Other
Development Services Department
Phone: 907-343-7904
On -Site Water & Wastewater Section Fax: 907-343-7997
Certificate of On -Site Systems Approval Application
1. GENERAL INFORMATION
Parcell.D. 015-135-19
Complete legal description Lakewood Hills #2, Lot 24A
Location (site address) 10581 Hillside Dr
Current property owner(s) Bradley Company LTD LLC Day phone (907) 345-8153
2. ON-SITE SYSTEMS SIZED FOR BEDROOMS
3. TYPE OF WATER SUPPLY: RN Private Well serving # dwelling units
0 Other Non-public well as regulated by MOA M Water Storage
r_1 Community Well or Public
4. TYPE OF WASTEWATER DISPOSAL: RN Private Septic E] Private Septic serving 2 dwelling units
M Holding Tank M Community Septic or Public Sewer
5. SEPTIC TANK: R Steel X Plastic F1 Concrete R Fiberglass
Age G2 - See advisory if steel or fiberglass older than 20 years
6. ABSORPTION FIELD: 0 AWWTS ❑ Bed RN Deep Trench R Wide Trench R Seepage Pit
Waiver request for: Distance:
Expedited review requested: ❑
By applying for this entitlement, this property is subject to inspection by municipal On-site staff
to verify the accuracy of the information provided.
COSA Fee $
Date of Payment
COSA #
Waiver Fee $
Date of Payment
Waiver #
COSA Application—Apr2025.doc
COSA Checklist_May2025.docx
COSA Checklist
Legal Description: Parcel ID:
If more than 1 well and/or septic system on lot, provide separate checklist. Structure served by this system ____
A. WELL DATA
Well log is filed with Onsite (or attached)
Date drilled Total depth ft
Cased to ft
Sanitary seal is functioning correctly
Wires are properly protected
Casing height (above ground) in.
Date of flow test for COSA
Static water level at beginning of test ft.
Well production at time of test gpm
Water storage tank volume gallons
Well disinfected for coliform test? Yes No
Coliform bacteria is Negative
Nitrate mg/L Nitrate less than MRL (ND)
Arsenic ug/L Arsenic less than MRL (ND)
Collected by
Date
Comments __________________________________________________________________________________
B. TANK DATA
Measured operating fluid level in septic tank
Date of pumping
Required maintenance completed, if AWWTS
Comments:
C. LIFT STATION
Required maintenance completed
Age of lift station years
Lift station material
Comments:
D. DISPOSAL FIELD DATA
Which system tested (date installed)
ALL standpipes present per record drawing
Total measured depth from grade ft (max)
Measured depth to pipe invert from grade ft (min)
N/A – pressurized field.
Per record drawings, field is insulated.
Monitor tubes go to bottom of effective.
If not, state depth into effective
Presoaked required if
(Required if house vacant or field not used for more
than 30 days prior to date of test)
Gallons introduced gallons date
Any rejuvenation treatment (past 12 months)
If yes, enter date
Adequacy test date
Results Pass
Fluid depth prior to test in
Water added gal
New fluid depth in
Elapsed time min
Final fluid depth in
Absorption rate gpd
FIELD STATUS – POST RECOVERY
Effective depth (per record drawings) in
Effective depth used in
Effective depth remaining in
Comments/Deficiencies:
COSA Checklist_May2025.docx
E. SEPARATION DISTANCES
From Well on Lot to:(Please enter distances if less than required)
Septic Tank/Lift Station on Lot > 100’
Yes if No ft
Neighboring Tank > 100’Yes if No ft
Disposal Field on Lot > 100’Yes if No ft
Neighboring Disposal Fields > 100’
Yes if No ft
Sewer Line/Main > 100’ Yes if No ft
Sewer Manhole/Cleanout > 100’
Yes if No ft
Sewer Service/Septic Line > 25’Yes if No ft
Holding Tank > 100’ Yes if No ft
Animal Containment > 50’Yes if No ft
Manure/Animal Excreta Storage > 100’
Yes if No ft
N/A – Served by Community Well (not on lot) or Public Water
From Septic/Holding Tank and Disposal Field(s) on Lot to:(Please enter distances if less than required)
Tank to Foundation > 10’Yes if No ft
Field to Foundation > 10’ Yes if No ft
Tank to Property Line > 5’ Yes if No ft
Field to Property Line > 10’ Yes if No ft
Water Main/Service Line > 10’Yes if No ft
Surface Water > 100’Yes if No ft
Wells on Adjacent Lots:
Wells > 100’Yes if No ft
Community Wells > 200’Yes if No ft
If tank or field is under driveway comment below
F. ENGINEER’S COMMENTS
G. CERTIFICATION & STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based
on procedures outlined in the Certificate of On-Site Systems Approval Guidelines, indicates that the on-site water
supply and/or wastewater disposal system appears to comply with applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation, unless noted otherwise.
Name of Firm Phone
Engineer’s Printed Name Date
LOT 6
REBAR
.----- C` C BGG !1M
LOT
IUTILITY I ALUMINUM
UTILITY PEDESTALS zx
N 00001'49" W 165.00'
o
- - - - -
*.-'4- HILLSIDE DRIVE - -
- - = .•4 T
' 1 22 2Co
i u SaIL o _�
0 20' 40' i� s ' , LS -14837
EASEMENTS OF RECORD, OTHER THAN THOSE SHOWN ON THE
RECORDED SUBDIVISION PLAT (2002-163) ARE NOT SHOWN HEREON.
THIS DOCUMENT DOES NOT CONSTITUTE BOUNDARY SURVEYAND
IS SUBJECT TO ANY INACCURACIES THATA SUBSEQUENT
BOUNDARY SURVEY MAY DISCLOSE.
UNDER NO CIRCUMSTANCES SHOULD ANY OF THE DATA HEREON BE
USED FOR CONSTRUCTION OF FENCES, IMPROVEMENTS, OR FOR
ESTABLISHING PROPERTY BOUNDARIES.
THIS SURVEY REPRESENTS A MORTGAGE LOCATION SURVEY
PREPARED IN ACCORDANCE WITH THE ASPLS MORTGAGE LOCATION
SURVEY STANDARDS.
THIS MORTGAGE LOCATION SURVEY SHOULD ONLY BE USED FOR A SINGLE PROPERTY
TRANSACTION. RE -USE OF THIS DRAWING BY THE ORIGINAL CLIENT OR BY OTHERS, FOR
ADDITIONAL USES ATA LATER DATE WITHOUT EXPRESS CONSENT OF THE SURVEYOR ISA
VIOLATION OF FEDERAL COPYRIGHT LAW. UNLESS GROSS NEGLIGENCE IS DISCOVERED,
THE LIABILITY EXTENT OF THE PREPARER SHALL BE LIMITED TO THE AMOUNT OF FEES
COLLECTED FOR SERVICES IN PREPARATION OF THIS PRODUCT.
JOB # 26109 I NO CORNERS SET THIS DATE I SCALE 1" = 40'
AS -BUILT
I HEREBY CERTIFY THAT I HAVE SURVEYED THE
FOLLOWING DESCRIBED PROPERTY:
LOT 24A, LAKEWOOD HILLS SUBDIVISION No. 2
ANCHORAGE RECORDING DISTRICT, ALASKAAND THAT
THE VISIBLE IMPROVEMENTS SITUATED THEREON ARE
WITHIN THE PROPERTY LINES AND NO VISIBLE
ENCROACHMENTS EXIST EXCEPTAS INDICATED.
DATED THIS 19th DAY OF MAY, 2026, AT ANCHORAGE,
ALASKA.
FIXED HEIGHT, LLC C.O.A.122554
Land Surveying Services WWW.FIXEDHEIGHT.COM
600 W 41 st. Ave, Ste. C, Anchorage, AK 99503 907.290.8949