Pump Installation Log
Arctic Pump & Well Inc .
Jim Sullivan
PO Box 770197
Eagle River, AK 99577
(907) 688 -2510
(907) 243 -2282
jim@arcticpump.com
SWosp231251
050751080000
9/7/2023
Teri Tr A 3
Dave Kelley
Eagle River AK 99577
9/11/2023
264 Feet
15SDQP-1.5HP-3RC
1.5 HP
14 Feet
S-50
Well Drilling Permit Number:
Parcel Identification Number:
Date Of Issue:
Legal Description
Lot:
Block:
Property Owner Name Address:
Pump Installaion Date:
Pump Intake Depth Below Top of Well Casing:
Pump Manufacturer's Name
Pump Model:
Pump Size:
Pitless Adapter Burial Depth:
Pitless Adapter Manufacturer's Name
Pitless Adapter Installer:
Well Disinfected Upon Completion?
Method of Disinfection:
u/k
Yes
Chlorine
Comments:
Pump Installer Name:
Arctic Pump & Well, Inc.
5Y
Thursday, September 14, 2023
MUNICIPALITY OF ANCHORAGE
On -Site Water & Wastewater Program
PO Box 196650 4700 Elmore Road
Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997
http://www.muni.org/onsite
On -Site Wastewater Disposal System Permit
Permit Number: OSP231251
Work Type: Septic Initial
Tax Code Number: 05075108000
Site Legal Address: TERI TR A3 G:0704
Site Mailing Address: 4386 BLYTHE WAY, Eagle River
Owner: KELLEY DAVID P & PAMELA R
Design Engineer: CREWDSON ENGINEERING, LLC
This permit is for the construction of:
Effective Date
Expiration Date:
Lot Size in Sq Ft
Total Bedrooms:
cnr
c �r Y� •'N i pits(%
11 J
Department
9/7/2023
9/6/2024
193581
Q Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy Q Private Well ❑ Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
Received By: 55 �Ir _ C \2(i t1 o S Date:
Issued By: Date: ✓ '�23
Ig
�1,I�UHMPAUTY OF ANcHOR GE
t r.�4
Development Services Department Phone: 907-343-7904
On -Site Water & Wastewater Section Fax: 907-343-7997
ON-SITE SEPTIC/WELL PERMIT APPLICATION
Parcel I.D. 050-751-08
Property owner(s) David & Pamela Kelley Day phone 907-250-8085
Mailing address 2800 Knik Avenue, Anchorage, AK 99517
Site address Unknown
Legal description (Sub'd., Block & Lot) Teri, Tract A3
Legal description (Township, Range & Section)
Lot Size 193,581 Sq. Ft. Number of Bedrooms 4
APPLICATION IS FOR:
APPLICATION IS AN:
TYPE OF DWELLING:
(® all that apply)
Absorption Field
Q
Initial 0
Single Family (SF) 0
(w/wo ADU)
Septic Tank
ElUpgrade
❑
Duplex (D) ElHolding
Tank
ElRenewal
El
Multiple Dwellings ❑
Privy
❑
(SF and/or D)
Private Well
Water Storage
❑
THIS APPLICATION INCLUDES A WAIVER REQUEST FOR:
Distance:
certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit/Rush Fees: k 5 � � Waiver Fees:
Date of Payment: g�/�23 Date of Payment:
Receipt Number: 0030.56-_ Receipt Number:
Permit No. 0,::� 10 2-2_� 12 J� I Waiver No.
GADevelopment Services\Building Safety\On Site Water and Wastewater\Forms\Client Forms\Permit Application.doc
James “Jay” Crewdson, P.E.
Email: CELLC.1@outlook.com
Cell/Text: (907) 280‐9493
Fax: (907) 688‐2295
PO Box 671389 ● 18368 Amonson Road ● Chugiak, Alaska 99567
August 11, 2023
Onsite Reviewer
Municipality of Anchorage
On‐site Water & Wastewater Program
4700 Elmore Road
Anchorage, AK 99519‐6650
Reference: Teri, Tract A3
Initial Septic System
Design Narrative
The property owner proposes to construct a 4‐bedroom septic system to serve a proposed 3‐bedroom
single family home. The well has already been drilled. The proposed septic system will use conventional
treatment and will not need any waivers if constructed as designed.
There are no anticipated probable adverse impacts to adjacent properties if the septic system is
constructed as designed. This includes: a. Wells; b. Wastewater disposal systems; c. Replacement disposal
sites; and d. Drainage flowing onto and off of the subject property that could adversely affect performance
of the wastewater disposal system.
Please feel free to contact me if you have any questions.
James “Jay” Crewdson, P.E.
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP231251, Curtis Townsend, 09/07/23
TH1
(P) 3 BR SFH
CONSTRUCT 4 BR
SEPTIC SYSTEM
(P)DEEP TRENCH
SOILS: BOH 18', DRY,
SP w/SILT AND GRAVEL, 3.2 MPI
4BR, AR 1.2, RA 500 SF
(2) 5'ED X 2'W x 25'L, TD 12'
THE DRAINFIELD IS DESIGNED
IAW STEEP SLOPE DISPOSAL
FIELD REQUIREMENTS. THE 3.2
MPI SOILS (HSG A) SHOULD USE
AN INFILTRATION LINE OF 45%
FOR DESIGN, WHICH IS MUCH
STEEPER THAN THE EXISTING
SLOPES AND IS HIGHLY
UNLIKELY TO ALLOW EFFLUENT
TO DAYLIGHT.
C1
M1
FC MH1
S1
DC
(P)SEPTIC TANK
GREER POLY 1250
(P)REPLACEMENT
SUBSURFACE DRAIN
BioMicrobics
BioBarrier 0.5 MBR
AR: 50 GPD/SF
0.5'EDx5'Wx5'L
34%
34%
36%
34
%
34%
36%
C3
M3
C4
M4
C2 M2
15' UTILITY EASEMENT
100' W
E
L
L R
AD
I
US
SPL
PL
34% GRO
U
N
D
SLOP
E
45
%
INFILT
R
A
T
I
ON L
I
NE
2.5'7.0'
50.0'
DRAINFIELD
James A. Crewdson
C11527REGISTEREDPROFESSIO N A L E N GINEER
PO Box 671389 Chugiak AK 99567 ● cellc.1@outlook.com
Cell/Text: 907-280-9493 ● Fax: 907-688-2295 ALLC #112279
Terri, Tract A3
SEPTIC SYSTEM DESIGN
PLAN
Prepared for:
David & Pamela Kelley
Permit: OSP231251
Date: 9-7-2023
Page: 2 of 2
ALL INFORMATION SHOWN ON THIS DOCUMENT IS THE PROPERTY OF CREWDSON ENGINEERING, LLC AND SHALL NOT BE USED FOR
ENGINEERING OR CONSTRUCTION PURPOSES WITHOUT WRITTEN PERMISSION FROM CREWDSON ENGINEERING, LLC
PLAN
SCALE: 1"=30'
LEGEND
(E)- existing
(P)- proposed
AMC - Anch. Muni. Code
AR - application rate
BGL - below ground level
BOH - bottom of hole/excavation
BR - bedroom
C# - cleanout
DC - double cleanout
ED - effective depth
EG - existing ground
FC - foundation CO
FG - finish grade
GPD - gallons per day
HSG - USDA hydrologic soils
group
IAW - in accordance with
M# - monitor tube
MH# - 24"Ø manhole
MOA - Munic. of Anch.
MPI - minute per inch
PL - property line
RA - required area
RF - reduction factor
SF - square foot
SPL - 50/50 splitter
SFH - single family home
ST - septic tank
TD - total depth
USDA - United States
Deptartment of Agriculture
NOTES
1. All proposed construction shall be in accordance with MOA code
requirements.
2. All property lines and easements within 20 feet of the proposed
improvements/construction shall be flagged by a licensed surveyor.
3. Septic Pipe
3.1. All pipe shall be 4"Ø ASTM D-3034 SDR-35 PVC
3.2. Conveyance pipe slope: 2% minimum
3.3. Drainfield distribution pipe slope: 0% (level)
4. Inspections and Notifications: All inspection notifications shall be made
to the engineer at 907-280-9493.
MOA Inspections and Notifications:
24 hour notice prior to the start of construction
2 hour notice prior to BOH inspections
ENGINEER Inspections and Notifications:
24 hour notice prior to pre-construction meeting
2 hour notice prior to top of tank plumbing inspection
2 hour notice of when final backfill and grading will be complete.
5. Insulation shall be in accordance with the code and the following
requirements.
5.1. 25-psi minimum burial grade rigid foam boards
5.2. The insulation board thickness (IT) and horizontal extension (IHE)
beyond each side of the insulated component below it shall be in
accordance with the following schedule:
DRAINFIELD SEPTIC TANK PIPES
Soil Cvr IT IHE Soil Cover IT IHE Soil Cover IT IHE
>3' none reqd >4' none reqd >4' none reqd
2' - 3' 2" 2' 2' - 4' 2" 2' 2' - 4' 2" 2'
Note: 2' min soil cover required over entire septic system.
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP231251, Curtis Townsend, 09/07/23
(E)WELL
TH1
(P) 3 BR SFH
CONSTRUCT 4 BR
SEPTIC SYSTEM
(P)DEEP TRENCH
SOILS: BOH 18', DRY,
SP w/SILT AND GRAVEL, 3.2 MPI
4BR, AR 1.2, RA 500 SF
(2) 5'ED X 2'W x 25'L, TD 12'
C1
M1
FC MH1
S1
DC
(P)SEPTIC TANK
GREER POLY 1250
(P)REPLACEMENT
SUBSURFACE DRAIN
BioMicrobics
BioBarrier 0.5 MBR
AR: 50 GPD/SF
0.5'EDx5'Wx5'L
34%
34%
36%
34%
34%
36 %
C3
M3
C4
M4
C2 M2
15' UTILITY EASEMENT
100' WELL RADIUS
SPL
PL
James A. Crewdson
C11527REGISTEREDPROFESSIO N A L E N GINEER
PO Box 671389 Chugiak AK 99567 ● cellc.1@outlook.com
Cell/Text: 907-280-9493 ● Fax: 907-688-2295 ALLC #112279
Terri, Tract A3
SEPTIC SYSTEM DESIGN
SITE PLAN
Prepared for:
David & Pamela Kelley
Permit: OSP231251
Date: 8-10-2023
Page: 1 of 2
ALL INFORMATION SHOWN ON THIS DOCUMENT IS THE PROPERTY OF CREWDSON ENGINEERING, LLC AND SHALL NOT BE USED FOR
ENGINEERING OR CONSTRUCTION PURPOSES WITHOUT WRITTEN PERMISSION FROM CREWDSON ENGINEERING, LLC
PLAN
SCALE: 1"=100'
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP231251, Curtis Townsend, 09/07/23
Performed For:
Legal Description:
Depth
(Feet
1-I OG
Municipality of Anchorage
Development Services Department
On -Site Water and Wastewater Section
4700 Elmore St.
P.O. Box 196650 Anchorage, AK 99519-6650
www.muni.org/onsite
(907)343-7904
Soils Log - Percolation Test
David Kelley
Teri, Tract A3
TH1
3-
4 SP with Silt
5-
6-
7-
E- •
8 -
WAS GROUND WATER
9- ENCOUNTERED? NO
10- SP with Silt and Gravel IF YES, AT WHAT DEPTH? L
Depth to Water After o
D P
11- Monitoring? Dry E
12- Date: 7-21-2023
13-
14-
15-
16-
17-
18- BOH
19-
20 -
COMMENTS
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANC
,,&1&,41251, Curtis To end. 09/07/
0 F Ajq %
h�PtE
Gross Time
Net Time
Depth to Water
Net Drop
•�
+cP�;••
CM son..,E+r
C11527,�,
Date Performed: 7-14-2023
Site Plan
See Design Drawing
See Design Drawing
Reading
Date
Gross Time
Net Time
Depth to Water
Net Drop
7-14-2023
minutes
inches
10
3.2
10
3.2
10
3.1
10
3.1
10
3.1
10
3.1
PERCOLATION RATE ;3,2 (minutesfinch) PERC HOLE DIAMETER b"
TEST RUN BETWEEN 7 FT AND 8 FT
PERFORMED BY: Crewdson Engineering i James Crewdson CERTIFY THAT THIS TEST WAS
PERFORMED IN ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: 7-14-2023