MUNICIPALITY OF ANCHORAGE
On -Site Water & Wastewater Program
PO Box 196650 4700 Elmore Road
Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997
http://www.muni.org/onsite
On -Site Water & Wastewater System Permit
Permit Number: OSP231283 Effective Date:
Work Type: WellSeptic Initial Expiration Date:
Tax Code Number: 06762119000
Site Legal Address: BEAR RIDGE LT 13 G:0804
Site Mailing Address:
Owner: DUBE JOSHUA & CHRISTINE Lot Size in Sq Ft:
Design Engineer: FORGE ENGINEERING Total Bedrooms:
This permit is for the construction of:
,Z,cn
xt S,
� n
r
De partine nt
9/6/2023
9/5/2024
54450
Q Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy Q Private Well ❑ Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
Special Provisions: Prior to construction, a new test hole is to be dug to confirm percolation rate. If a design
change is required, submit a change order.
/V�/W 5c) (c-
10 f I 1-�'o
f— r-o, U-OLc'[
Received By: 1,55 UCD —1-0 r- ()2— C Date:
r --
Issued By: Date: v -ZO 2 3
4
MUMUPAUTY OF ° HCE- O AG
d
Community Development Department Phone: 907-343-7904
Development Services Division Fax: 907-343-7997
On -Site Water & Wastewater Program
ON-SITE SEWER/WELL PERMIT APPLICATION
Parcel I.D. 067-621-19
Property owner(s) Joshua & Christine Dube
Mailing address 3474 Bear Ridge Circle, Eagle River, AK 99577
Site address NHN Bear Ridge Circle, Eagle River, AK 99577
Legal description (Sub'd., Block & Lot) Bear Ridge Lot 13
Day phone 907-227-6644
Legal description (Township, Range & Section)
Lot Size 54,450 Sq. Ft. Number of Bedrooms 4
APPLICATION IS FOR:
APPLICATION IS AN: TYPE OF DWELLING:
(2 all that apply)
Absorption Field
❑X
Initial ❑X Single Family (SF) ❑X
(w/wo AD U)
Septic Tank
❑X
Upgrade ❑
(D) ❑
Holding Tank
❑
RenewalDuplex
❑
Multiple Dwellings ❑
Privy
❑
(SF and/or D)
Private Well
0
Water Storage
❑
THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
L
(Signature of property owner or authorized agent)
Permit/Rush Fees: gZD fY92 Waiver Fees:
Date of Payment: 2 S 2023 Date of Payment:
Receipt Number: l'� �1' 0 Receipt Number:
Permit No. Waiver No.
Permit App_'-'-:- ,'-.,:c
September 6, 2023
MOA Development Services, On-Site Water & Wastewater Program
4700 Elmore Rd
Anchorage, AK 99507
Subject: Bear Ridge Lot 13 – NHN Bear Ridge Cir
Septic system design
Dear On-Site Services Engineer:
The owner of the above lot intends to build a 4-bedroom home on the property, so we are
submitting this permit application for the construction of a new well and septic system. The
attached site plan identifies the location of the home as well as the proposed well, septic location
and alternate site.
The ground surface on the lot slopes fairly uniformly to the southwest at between 15 and 20%,
with a few shallower or steeper areas. There are no slopes greater than 25% within 50 feet
downslope of either the primary or alternate site. Contours are shown on the site plan showing the
grade and direction of flow. Stormwater drainage will not impact this septic system. The new
trench will be constructed parallel to the slope as much as possible.
We have designed this system using the soils information available in the subdivision septic
feasibility files. Along with this, we are specifying that a confirmation test hole must be dug at the
time of installation to confirm that the soils are consistent.
Wells on this and adjacent lots are shown. No conflicts exist between this proposed system and
any other well or septic system, whether on this lot or adjacent lots. The new system will be a
minimum of 100’ from all wells and surface water, and more than 5’ away from the septic tank.
The alternate site is located more than 6’ away. Please refer to the attached plan and profile pages
for the septic design. If this design is followed, there will be no adverse impacts to adjacent
properties.
Sincerely,
Benjamin Schiller, PE
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP231283, Curtis Townsend, 09/06/23
BEAR RIDGE, LOT 13 Co
730
720
710
LOT 14
\ x' T&E{ G
\ I � VACANT) ,, \
4T \
I \ 70n 10'
EASEM \ \\\o \
NEW WELL
LOCATION
V A \ 1 v
J 680
I
70,E tA,
�\ I o / 1 \
670, I _ _ _� \ `N 1,500-GAL / I
STEP NK \ n t
l r
I
W
Z
WWLf)
\`,fn
-W
�Z;\
O '' MT
\ \ \ TH#13
APPROX SUBDIVISION TEST \ �`�
HOLE LOCATION: DIG'' MT - -
i I CONFIRMATION TEST HOLE - MT
j I PRIOR TO INSTALLATION
660 I \
\ALTERNATE SITE
(2)x60' hONG x 5' WIDE, 0.5' EFFECTIVE \ I I
\ (DEPTH ABSORPTION TRENCH\ I
LOT12
\
I
URGE
ENG I NEE RING
SEPTIC PLAN
0 50 100
FEET
1 "=50'
LEGEND
CO - CLEANOUT
2CO - DOUBLE CLEANOUT
FCO - FOUNDATION CLEANC
FS - FLOW SPLITTER VALVE
MH - MANHOLE
MT - MONITORING TUBE
SV - SEPTIC VENT
TH - TEST HOLE
BEAR RIDGE, LOT 13 Co 91
DESIGN FACTORS: SYSTEM REQUIREMENTS:
600 GPD PEAK FLOW 5-WIDE TRENCH SYSTEM
PERK RATE: <1 MIN/IN 1,500-GAL STEP TANK
APPLICATION RATE: 1.0 GPD/SF
600 GPD / 1.0 GPD/SF / 5' WIDE * 1.0 RED FACTOR [0.5 DEEP] = 120 LF TRENCH REQUIRED
(120 LF SPECIFIED)
BOTTOM OF TRENCH: 1' BELOW GRADE
FLOW LINE ELEVATION: 0.5' BELOW GRADE
BOTTOM OF SAND: T BELOW GRADE
i5a
TYPICAL TRENCH SECTION
(NO SCALE)
NOTES:
1. GRADE AREA OVER TRENCH TO DRAIN AWAY
2. PROVIDE T OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2'
WITH 2" OF INSULATION
3. CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER
THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY
OVIDE ADDITIONAL FILL
ENSURE MINIMUM
VER AFTER SETTLEMENT
;ULATION
OTEXTILE FABRIC
PVC w/ 30 - %"
IFICES EVENLY
\CED @ 4.0' OC
kINFIELD ROCK
OA-APPROVED SAND
F MGE
L'-'- ��y`✓y� E N G IN E E R 1 N G
°F'q�l�►.
. �-�
......... ..........
Benja 'n Schiller
. CE 12592AMP
8122123
PROFESSIONP��®
DEPTH
(feet)
1-
2-
3-
4-
5 -
6-
7-
8-
9-
10-
11-
12-
13-
14-
15-
16-
17-
18-
19-
' GE SOILS LOG AND PERCOLATION TEST
ENGINEERING
LEGAL DESCRIPTION: BEAR RIDGE, LOT 13
PERFORMED FOR: JOSHUA & CHRISTINE DUBE
DATE: 9/ 13 / 2 3 PARCEL ID#: 0 6 7- 6 21-19
TEST HOLE 1
IIIIII II 1'OB
' PERC TEST LOCATION
GM (SANDY GRAVEL)
GM (SILTY GRAVEL)
NO WAS WATER ENCOUNTERED?
- IF YES @ WHAT DEPTH?
7.5 ' DEPTH TO WATER AFTER MONITORING
9/20123 DATE OF MONITORING
DATE
READING
START TIME
NET TIME
(MINUTES)
DjIEPAT
TET O
(INCHES)
NET DROP
(INCHES)
9/13/23
1
2:15 PM
1:09
1 Ts"
7 -1"
616 16"
2
2:24
1 -s"
7 -1'
6 -s I
3
2:57
1 -1"
7 -1"
6 o"
4
3:19
1 �s"
7 16"
6 Tsl
5
3:36
1 fs"
7 &'
6 &'
6
3:39
1 Ts"
7 is"
6 �s
Yr,Mk,ULA 11UN KA l t: UJO (MIN/INCH)
COMMENTS: USCS SOIL CLASSIFICATION WAS VISUALLY DETERMINED
SITE PLAN
TECHNICIAN: M. JAKUBISIN