Certificate of On -Site Systems Approval
Parcel I.D. 051-191-29
Legal description SKYLINE VIEW #1 BLK 3 LT 3
Site address 23137 ELDER DR
Expiration Date: 1/30/2024
Current property owner(s) MCCLURE LA REVOCABLE TRUSTMCCLURE LINDA ANN / TRUSTEE
XThe On-site system(s) is/are approved for 3 bedrooms
Conditional approval for bedrooms, with the following stipulations:
Comments or advisories:
By: ILAOriginal Certificate Date: 10/30/2023
This Certificate of On -Site Systems Approval (COSA) is intended to demonstrate the subject
system(s) is/are in substantial compliance with municipal code. The Municipality of
Anchorage, Development Services Department (DSD) issues COSAs based upon
representations provided by an independent professional engineer. The Municipality of
Anchorage is not responsible for errors or omissions in the professional engineer's work.
ATTACHMENTS:
COSA Checklist X Well Flow Advisory
Absorption Field Advisory Nitrate Advisory
Tank Age Advisory Arsenic Advisory
Other
COSA Approval_June 2022
MUNICIPALITY OF ANCHORAGE Rultovi
Development Services Department Phone: 907-343-7904
On -Site Water & Wastewater Section Fax: 907-343-7997
Certificate of On -Site Systems Approval Application
1. GENERAL INFORMATION
Parcel I.D. 051-191-29
Complete legal description SKYLINE VIEW #1 BLOCK 3, LOT 3
Location (site address) 23137 ELDER DRIVE, CHUGIAK, AK 99567
Current property owner(s) MCCLURE LA REVOCABLE TRUST
2. ON-SITE SYSTEMS SIZED FOR 3 BEDROOMS
Day phone
3. TYPE OF WATER SUPPLY: ® Private Well ❑ Private Well serving 2 dwelling units
❑ Private Well serving 3+ dwelling units ❑ Community Well or Public
❑ Water Storage
4. TYPE OF WASTEWATER DISPOSAL: ® Private Septic ❑ Private Septic serving 2 dwelling units
❑ Holding Tank ❑ Community Septic or Public Sewer
5. SEPTIC TANK: ❑ Steel ❑ Plastic ® Concrete ❑ Fiberglass
Age UNKNOWN CIRCA 1970 - See advisory if steel older than 20 years
6. ABSORPTION FIELD: ❑ AWWTS ❑ Bed ® Deep Trench ❑ Wide Trench ❑ Seepage Pit
Waiver request for: Distance:
Expedited review requested:
By applying for this entitlement, this property is subject to inspection by municipal On-site staff
to verify the accuracy of the information provided.
COSA Fee $ 4 y 9
Date of Payment
COSA # C7,� 1 Zy
Waiver Fee $
Date of Payment
Waiver #
COSA Application.doc
COSA Checklist.docx
COSA Checklist
Legal Description: SKYLINE VIEW #1 BLOCK 3, LOT 3 Parcel ID: 051-191-29
If more than 1 well and/or septic system on lot, provide separate checklist. Structure served by this system ____
A. WELL DATA
Well log is filed with Onsite (or attached)
Date drilled UNKNOWN Total depth 50 ft
Cased to UNKNOWN ft
Sanitary seal is functioning correctly
Wires are properly protected
Casing height (above ground) 12+ in.
Date of flow test for COSA 9/30/2023
Static water level at beginning of test 30 ft.
Well production at time of test 4.6 gpm
Water storage tank volume NA gallons
Well disinfected for coliform test? Yes No
Coliform bacteria is Negative
Nitrate 4.84 mg/L Nitrate less than MRL (ND)
Arsenic ug/L Arsenic less than MRL (ND)
Collected by Date 9/20/23
Comments WELL DATA UNKNOWN – CIRCA 1970s. Sullivan installed new sanitary seal & conduit.
B. TANK DATA
Measured operating fluid level in septic tank 67”
Date of pumping 10/23/2023
Required maintenance completed, if AWWTS
Comments: Concrete tank was holding effluent
C. LIFT STATION
Required maintenance completed
Age of lift station years
Lift station material
Comments:
D. ABSORPTION FIELD DATA
Which system tested (date installed) NEW SYSTEM
ALL standpipes present per record drawing
Total measured depth from grade 10.30 ft (max)
Measured depth to pipe invert from grade 5.17 ft (min)
N/A – pressurized field.
Per record drawings, field is insulated.
Monitor tubes (MT) go to bottom of effective (ED)
If not, state depth into effective
Presoaked required if
(Required if house vacant or field not used for more
than 30 days prior to date of test)
Gallons introduced gallons date
Any rejuvenation treatment (past 12 months) N
If yes, enter date
Adequacy test date NEW SYSTEM
Results Pass
Fluid depth prior to test in
Water added gal
New fluid depth in
Elapsed time min
Final fluid depth in
Absorption rate gpd
FIELD STATUS –– NEW FIELD
Effective depth (per record drawings) 60 in (MOA 5’ ED)
Effective depth used 0 in
Effective depth remaining 60 in
Comments/Deficiencies: Approximate total measured depths from existing grade.
COSA Checklist.docx
E. SEPARATION DISTANCES
From Private Well on Lot to: (Please enter distances if less than required or if community well on lot)
Septic Tank/Lift Station on Lot > 100’
Yes if No ft
Neighboring Tank > 100’ Yes if No ft
Absorption Field on Lot > 100’ Yes if No ft
Neighboring Absorption Fields > 100’
Yes if No ft
Community Sewer Main > 75’ Yes if No ft
Community Sewer Manhole/Cleanout > 100’
Yes if No ft
Private Sewer/Septic Line > 25’ Yes if No ft
Holding Tank > 100’ Yes if No ft
Animal Containment > 50’ Yes if No ft
Manure/Animal Excreta Storage > 100’
Yes if No ft
N/A – Served by Community Well (not on lot) or Public Water
From Septic/Holding Tank and Absorption Field(s) on Lot to: (Please enter distances if less than required)
Building Foundations > 10’ Yes if No ft
Tank to Property Line > 5’ Yes if No ft
Field to Property Line > 10’ Yes if No ft
Water Main > 10’ Yes if No ft
Water Service Line > 10’ Yes if No ft
Surface Water > 100’ Yes if No ft
Wells on Adjacent Lots:
Private Wells > 100’ Yes if No ft
Community Wells > 200’ Yes if No ft
If tank or field is under driveway comment below
F. ENGINEER’S COMMENTS
G. CERTIFICATION & STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based
on procedures outlined in the Certificate of On-Site Systems Approval Guidelines, indicates that the on-site water
supply and/or wastewater disposal system appears to comply with applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation, unless noted otherwise.
Name of Firm FIRST WATER CONSULTING Phone 907-350-9566
Engineer’s Printed Name CURTIS HUFFMAN, PE Date 10/30/2023
Comments: This investigation was completed in compliance with MOA guidelines, regulations,
and best industry practices / methods. The assessment of the condition of the well and septic
applies only to the conditions as of the day tested. The flow and absorption rates may change
due to subsurface conditions that may not be observed from the surface, changes in land use,
local soil characteristics, groundwater levels that may fluctuate during the year, quality of
construction (workmanship & materials), the water usage of the family being served by the
system and maintenance. The operational life of all well and septic systems are subject to
these various and dynamic characteristics and are outside the control of the evaluator of the
well and septic system. Therefore, any or NO estimate of how long a system will function satisfactory
for current or future occupants or guarantee that no unseen encroachments, deficiencies or
discrepancies exist can be given by First Water Consulting &
10/30/23
Municipality of Anchorage
On -Site Water and Wastewater Section • (907) 343-7904 Page of
ON-SITE WASTEWATER INSPECTION REPORT
Permit Number: OSP231330 PID Number: 051-191-29
Dwelling: ® Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: ❑ New ® Upgrade
Name
MCCLURE LA REVOCABLE TRUST
ABSORPTION FIELD
® Deep Trench ❑ Wide Trench ❑ Bed ❑ Mound
Site Address
23137 ELDER DRIVE, CHUGIAK, AK
❑ Other
Phone
Number of Bedrooms
Soil Rating
Total depth from original grade
3
1.2 GPD/SF
10 Ft.
LEGAL DESCRIPTION
Depth to pipe invert from original grade
5 Ft.
Gravel depth beneath pipe
5 Ft.
Subdivision Block Lot
SKYLINE VIEW #1 3 3
Fill added above original grade
VARIES 0.17 — 0.3 Ft.
Gravel length
40 Ft.
Township Range Section
Gravel width
3 Ft.
Beds: Number of Lines
Distance between lines
I Ft.
SEPARATION DISTANCES
To
Septic
Absorption
Lift Station
Holding
Sewer
Total absorption area
Number of trenches
Dist. between trenches
From
Tank
Field
Tank
Line
400 Ft2
1
-- Ft.
Well
100'+
100'+
25'+
TANK ® Septic ❑ S.T.E.P. ❑ Holding ❑ Other
Manufacturer
Capacity
Surface Water
100'+
100'+
EXISTING UNKNOWN
1000+ Gal.
Material
Number of compartments
Lot Line
51+
10'+
NA
CONCRETE
1
Foundation
10'+
10'+
LIFT STATION
Manufacturer
Capacity
Remarks Existing concrete tank w/ new inlet/outlets &
Gal.
sealed w/ caulking & bentonite.
Alarm location
Electrical installed by
Installer JRS
PIPE MATERIAL House to tank 3034 Tank to 3034
drainfield
Drainfield 3034 CO/MT 3034
Inspector FWC
BENCH MARK (Assumed elevation) 100 ft
Inspdection 15` 10/23/23 2„d 10/24/23
Location and description
3rd 10/24/23 4d'
BOTTOM OF SIDING
ON-SITE WATER AND WASTEWATER SECTION APPROVAL
\
.« !�_\`c�`�j
Conditional Approval: Date
=�
.. .......��/.
•• •• •••• ••••.....•%
Septic System
App rove -
% Curtis Huffman
Date ��
�``ci�,•,. CE 128991 •.. ���/�
lF 10/30/23.
ilyF�PROFESSIO0��
Note: this a7vales not include well permit requirements.
iQo., n�in�ran�
PID:051-191-29 PERMIT:OSP231330
FIRST WATER CONSULTING
SKYLINE VIEW #1 BLOCK 3, LOT 3
N 89 59'W 35700 DO TSERRY DRIVE
LR.fL%/LN/.f Vr RLIVRUi V/ALR 111" l/1V.)L RYYLARI/YG VN 111 AL LVRU YLRI i R/fL NVl J/1Vl//lV
!i2 HEREON ( UNLESS INDICATED)
NOTE: FENCELINES THAT MAY APPEAR ON THIS DRANING ARE NOT TO BE USED TO DETERNNE
2C' PROPERTY LINES OR POSITION ADDITIONAL IMPROVEMENTS.
ANY PAVING SHONN HEREON MAY BE APPROXIMATE DUE TO EXCESSIVE SNOB/ AND/OR ICE.
ELDER DRI VE
THESURVEYDATA AND MEASUREMENTS HEREONAREPREPARED FOR THE
OWNER OF RECORD AS OF THE DATE OF THIS SURVEY.
ANY USE OF THIS DRAWING BY THIRD PARTIES IS PROHIBITED UNLESS
WRITTEN PERMISSION IS PROVIDED.
�Q•�� OF
c . 49 1H -
SHANE A. HOLT /
LS-695�Q4� a 14a o
fessiona� foo
AS-BUILTSURVEY i" =.30'
NO CORNERS SET THIS DATE
I HEREBY CERTIFY THA T I HA VE PERFORMED A SURVEY
OF THE FOLLOWING DESCRIBED PROPERTY
LOT3 BLOCK3 SKYLINE VIEWFIRSTADD'N.
A NCHORA GE RECORDING DISTRICT, ALASKA, AND THAT THE
VISIBLEIMPROVEMENI S SITUATED THEREON ARE WITHIN
THE PROPERTYLINES AND NO VISIBLE ENCROACHMENTS
EXIST OTHER THAN NOTED.
DATED ATANCHORAGE,ALASKA THIS 27TH DAYOF
OCTOBER 2023
15928 234-22 235-2
HOLT LAND SURVEYING
9309 GROVER DRIVE
ANCHORAGE,AK 99507
223-8615
MUNICIPALITY OF ANCHORAGE
On -Site Water & Wastewater Program
PO Box 196650 4700 Elmore Road
Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997
http://www.muni.org/onsite
On -Site Wastewater Disposal System Permit
Permit Number: OSP231330
Work Type: Septic Upgrade
Tax Code Number: 05119129000
Site Legal Address: SKYLINE VIEW #1 BLK 3 LT 3 G:1159
Site Mailing Address: 23137 ELDER DR, Chugiak
Owner: MCCLURE LA REVOCABLE TRUST
Design Engineer: FIRST WATER CONSULTING
This permit is for the construction of:
Effective Date:
Expiration Date:
�1»cnt 'S,
r
Q .
ueh�irtii,enc
Lot Size in Sq Ft:
Total Bedrooms:
10/2/2023
10/1/2024
95850
2 Disposal Field 2 Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
Issued By:
Date:
Date: /0ZZ 2
3
MUHMPAU77of °HCHOv,,GE:
Development Services Department Phone: 907-343-7904
On -Site Water & Wastewater Section 6 Fax: 907-343-7997
ON-SITE SEPTIC/WELL PERMIT APPLICATION
Parcel 1. D. 051-15;.-' 29
Property owner(s) MCCLURE LA REVOCABLE TRUST Day phone
Mailing address 23740 SUNNY GLEN DR, EAGLE RIVER, AK 99577
Site address 23137 ELDER DRIVE, CHUGIAK, AK 99567
Legal description (Sub'd., Block & Lot) SKYLINE VIEW #1 BLOCK 3, LOT 3
Legal description (Township, Range & Section)
Lot Size 95,850 Sq. Ft. Number of Bedrooms 3
APPLICATION IS FOR:
APPLICATION IS AN:
TYPE OF DWELLING:
(® all that apply)
Absorption Field
0
Initial ❑
Single Family (SF) x❑
ADU)
Septic Tank
M(w/wo
Upgrade x❑
(D) El
Holding Tank
❑
RenewalDuplex
❑
Multiple Dwellings ❑
Privy
❑
(SF and/or D)
Private Well
❑
Water Storage
❑
THIS APPLICATION
INCLUDES
A WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit/Rush Fees: g'9 �- Waiver Fees:
Date of Payment: C 2 Z 3 Date of Payment:
Receipt Number: r�1 Receipt Number:
Permit No.y5 P 2 3 �3 � O Waiver No.
G1Development Services\Building Safety\On Site Water and Wastewater\Forms\Client Forms\Permit Application.doc
13030 Sues Way, Anchorage, AK 99516
907-350-9566 / FirstWaterAK@gmail.com
!
!!
September 26, 2023
Municipalities of Anchorage
On-Site Water & Wastewater Program
4700 Elmore Road
Anchorage, AK 99507
RE: SEPTIC SYSTEM UPGRADE PERMIT
LEGAL: SKYLINE VIEW #1 BLOCK 3, LOT 3
The property owner has requested we obtain a permit to upgrade the undocumented septic
system of the above referenced lot. We propose to install one deep trench and 1000-gallon tank
to serve the existing 3-bedroom residence. We would recommend consideration of a 1500-
gallon HDPE tank be installed for current functionality and future consideration or flexibility. No
groundwater was noted in the MOA on-site files, but if groundwater is encountered during tank
installation an epoxy coated steel septic tank may be required.
The design is based on the recent test hole conducted on September 19, 2023. No groundwater
was observed at test hole excavation or monitoring. The slopes are moderate at 3 -8% at the
proposed upgrade location. The lot and area are served by private water. The design will not
impact any of the neighboring properties. Please contact us if you have any questions.
Sincerely,
Curtis Huffman, P.E.
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP231330, Deb Wockenfuss, 10/02/23
FIRST WATER CONSULTING
SKYLINE VIEW #1 BLOCK 3, LOT 3
DESIGN CALCS:
NO WELLS WITHIN
100' OF PROPOSED
SEPTIC SYSTEM
NO SLOPES >25% WITHIN 50'
OF PROPOSED FIELD.
NO WELLS WITHIN
100' OF PROPOSED
SEPTIC SYSTEM. ALSO
RE-VERIFY AT CONST.
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP231330, Deb Wockenfuss, 10/02/23
FIRST WATER CONSULTING
DESIGN DETAILS:
SKYLINE VIEW #1 BLOCK 3, LOT 3
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP231330, Deb Wockenfuss, 10/02/23
3030 Sues Way - Anchorage, Alaska 99516
Tel. 907-350-9566 firstwaterAK@gmail.com
SOILS LOG - PERCOLATION TEST
LEGAL : SKYLINE VIEW #1 BLOCK 3, LOT 3
PERFORMED BY: FWC - I CURTIS HUFFMAN CERTIFY THAT THIS TEST WAS
PERFORMED IN ACCORDANCE WITH ALL STATE & MUNICIPAL GUIDELINES IN EFFECT
ON THIS DATE. DATE: 9/26/2023
DEPTH
FEET OG
SOILS
1
ORG/OL
2 GW
3
4
5
6
GM/gp-sp
7
8
9
10
11
12
13
14
15
16
17
18
BOH
19
20
Reading Date Gross
Time
Net
Time
Depth to
Water
Net Drop
9/19/23 10 min 6 5 15/16
6 5 14/16
6 5 14/16
6 5 13/16
6 5 14/16
6 5 13/16
PERCOLATION RATE 1.7 (MIN / INCH)
TEST RUN BEWTWEEN 5 & 6 FT
PERC HOLE DIAMETER 6
PRE-SOAKED PRIOR TO TEST & ALL READINGS TO
THE 1/16TH.
GROUND WATER ENCOUNTERED: NO
IF YES, AT WHAT DEPTH: NA
DEPTH TO WATER AT MONITORING: DRY
DATE: 9/26/23
TESTHOLE # 23-1 DATE PERFORMED: 9/19/23
SEE SITE PLAN FOR SLOPE & LOCATION
COMMENTS:
VERIFY GROUNDWATER MT
AT TIME OF CONSTRUCTION
PERFORMED FOR: LINDA ANN MCCLURE TRUST
9/26/2023
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP231330, Deb Wockenfuss, 10/02/23
N 89 59'W 35700 DO TSERRY DRIVE
LR.fL%/LN/.f Vr RLIVRUi V/ALR 111" l/1V.)L RYYLARI/YG VN 111 AL LVRU YLRI i R/fL NVl J/1Vl//lV
!i2 HEREON ( UNLESS INDICATED)
NOTE: FENCELINES THAT MAY APPEAR ON THIS DRANING ARE NOT TO BE USED TO DETERNNE
2C' PROPERTY LINES OR POSITION ADDITIONAL IMPROVEMENTS.
ANY PAVING SHONN HEREON MAY BE APPROXIMATE DUE TO EXCESSIVE SNOB/ AND/OR ICE.
ELDER DRI VE
THESURVEYDATA AND MEASUREMENTS HEREONAREPREPARED FOR THE
OWNER OF RECORD AS OF THE DATE OF THIS SURVEY.
ANY USE OF THIS DRAWING BY THIRD PARTIES IS PROHIBITED UNLESS
WRITTEN PERMISSION IS PROVIDED.
�Q•�� OF
c . 49 1H -
SHANE A. HOLT /
LS-695�Q4� a 14a o
fessiona� foo
AS-BUILTSURVEY i" =.30'
NO CORNERS SET THIS DATE
I HEREBY CERTIFY THA T I HA VE PERFORMED A SURVEY
OF THE FOLLOWING DESCRIBED PROPERTY
L 0 T 3 BLOCK3 SK YL INE VIEW FIRS TADD7V
A NCHORA GE RECORDING DISTRICT, ALASKA, AND THAT THE
VISIBLE IMPROVEMENT S SITUATED THEREON ARE WITHIN
THE PROPERTYLINES AND NO VISIBLE ENCROACHMENTS
EXIST OTHER THAN NOTED.
DATED ATANCHORAGE,ALASKA THIS 17TH DAYOF
SEPTEMBER 2023
HOLT LAND SURVEYING
9309 GROVER DRIVE
ANCHORAGE,AK 99507
15928 234-22 223-8615