HomeMy WebLinkAboutCANYON VIEW ESTATES BLK 1 LT 8I' • 0 Municipality of Anchorage On-Site Water and Wastewater Section - (907) 343-7904 Page 1 of 1 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP241000 PID Number: 021-021-41 Dwelling: 0 Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: ❑* New ❑ Upgrade Name Hultquist Homes ABSORPTION FIELD El Deep Trench 9Wide Trench El Bed ❑Mound Site Address 13801 Canyon Road ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 5 1.2 GPD/SF 2.0 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade Ft. Gravel depth beneath pipe 0.5 Ft. Subdivision Block Lot Canyon View Estates 1 8 y ill Fill added above original grade Ft. Gravel length 2 @ 75 Ft. Township Range Section Gravel width 5.0 Ft. Beds: Number of Lines n/a Distance between lines n/a Ft. SEPARATION DISTANCES TO From Septic Tank Absorption ;Lift Station Field Holding !, Sewer Tank Line Total absorption area 750 Ft2 Number of trenches 2 Dist. between trenches 7.4 Ft. Well 100'+ 100'+ NA NA 25'+ TANK ❑p Septic ❑ S.T.E.P. ❑ Holding ❑ Other Manufacturer Greer (Deep Bury) Capacity 1500 Gal. Surface water 100'+ 100'+ NA NA Material Number of compartments Lot Line 5'+ 10'+ NA NA NA HDPE 2 Foundation10'+ 10'+ NA NA LIFT STATION Manufacturer Capacity Remarks Gal. Alarm location Electrical installed by Installer Brownson Bros PIPE MATERIAL House to tank D3034 Tank to D3034 drainfield Drainfield D3034 CO/MT D3034 Inspector Pannone Engineering Services BENCH MARK (Assumed elevation) 100.0 ft n 1�t 3/25/24 nd 3/26/24 Inspdeact s2 3'd 3/26/24 4" 4/19/24 Location and description See Site Plan, Bottom Sheathing. ON-SITE WATER AND WASTEWATER SECTION APPROVAL Engineer's Stamp Conditional Approval: Date Systemj' Approved Date Not this approval does not include well permit requireme ts. \ �� OF• A/gs,ll ® o CE S"14C-)Septic , .F�.�......r.�.�.Steven k. Pannone (Rev 05/02/18) / PA N N O N E E N G S V C , L L C ( C . I . 1 0 8 8 ) 1500 GAL GREER POLY TANK PROFILE PA N N O N E E N G S V C , L L C ( C . I . 1 0 8 8 ) Certified Drilling Log OWNER OF LAND: Hultquist Homes ADDRESS: 13801 Canyon Rd. Anchorage, AK 99516 LEGAL DESCRIPTION Canyon View Blk 1 Lot 8 DATE: 3/4/24 PERMIT NUMBER: OSP241000 DATE OF ISSUE: 1/3/24 TAX IDENTIFICATION NUMBER 02102141000 Is well located at approved permit location: Yes No Method of Drilling: air rotary cable tool Depth of Well: 300’ Casing Type: Steel Wall thickness .250 inches Diameter: 6 inches, depth 44 feet Liner type Static Water Level: 106.2 feet Recovery Rate 1.5 gpm gph Method of Testing Air Well Intake Opening Type: open end open hole Screened Start feet Stopped Perforations Start feet Stopped Grout Type: Bentonite Volume: 250 lbs. Depth: from 2 feet, to 42 feet Well Disinfected Upon Completion: yes no Method of Disinfection: Chlorine 50 PPM Comments: Shallow bedrock surface seal to MOA code Bore Hole Data Depth From To 0 2 Casing Stickup 2 4 Overburden 4 10 Gravel 10 14 Bedrock broken 14 180 Bedrock 180 290 Bedrock hard 290 300 Bedrock fractured Drillers Name: Cole Sullivan ATTENTION: It is the responsibility of the property owner to submit a copy of the well log to the proper authority. Municipality of Anchorage: Department of Health & Human Services and/or Department of Environmental Conservation. MatSu Borough: Department of Environmental Conservation. www.sullivanwaterwells.com Pump Installation Log Well Drilling Permit Number: OSP 241000 Date of Issue 1/3/24 Parcel Identification Number: 02102141000 Legal Description Property Owner Name & Address CANYON VIEW ESTATES BLK 1 LT 8 Hultquist Homes 13801 Canyon Rd. Anchorage, AK 99516 Pump Installation Date: 10/16/24 Pump Intake Depth Below Top of Well Casing: 292 feet Pump manufacturer’s Name: Grundfos Pump Model: 10SQE15-330 Pump Size: 1.5 hp Pitless Adapter Burial Depth: 12 feet Pitless Adapter Installer: Pitless Manufacturer: Disinfected Upon Completion? yes no Method of Disinfection: Chlorine 50 PPM Comments: Pump Installers Name: Sullivan Water Wells Attention: The pump installer shall provide a pump installation log to the DSD within 30 days of pump installation. Merrill Unknown MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Water & Wastewater System Permit Permit Number: OSP241000 Work Type: WellSeptic Initial Tax Code Number: 02102141000 Site Legal Address: CANYON VIEW ESTATES BLK 1 LT 8 G:3042 Site Mailing Address: 13801 CANYON RD, Anchorage Owner: HULTQUIST HOMES INC Design Engineer: PANNONE ENGINEERING SERVICES This permit is for the construction of: Effective Date: Expiration Date Lot Size in Sq Ft: Total Bedrooms: »>cnr t�epactment 1 /3/2024 1 /2/2025 72058 Q Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy Q Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Received By: Date: Issued By: Date: 3 Z O 2 Y 5 MUNICIPALITY OF ANCHORAGE -% o;. r' :a lip r Community Development Department Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On -Site Water & Wastewater Program ON -SITE SEWER/WELL PERMIT APPLICATION +,, Parcel I.D. 021-021-41 R_ Property owner(s) Hultquist Homes Inc Mailing address Site address NSN Canyon Road Day phone Legal description (Sub'd., Block & Lot) Canyon View Estates, Block 1, Lot Legal description (Township, Range & Section) Lot Size 72,05$ Sq. Ft. Number of Bedrooms 5 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (® all that apply) Absorption Field 0 Initial R Single Family (SF) 0 ADU) Septic Tank ❑X Upgrade El(w/wo Duplex (D) El Holding Tank ❑ Renewal ❑ Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑X Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: IS/2- Waiver Fees: Date of Payment: Receipt Number: Permit No. 05PZ_ 41 t %' 00 Date of Payment: Receipt Number: Waiver No. Permit App_*- : ....:c Pannone i eei ices LLc Steven R. Pannone, Principal Registered Professional Engineer E-mail: steve@paneneak.com 13 December 2023 Municipality of Anchorage Development Services Department On -Site Water & Wastewater Program 4700 Elmore Road P. 0. Box 196650 Anchorage, Alaska 99519 Subject: Canyon View Estates, Block 1, Lot 8 Septic System and Well Permit Request This is a design narrative for a permit to install a new septic system and well on the subject property. The proposed system will serve a proposed five -bedroom (5) house. This lot and surrounding lots are served by private wells. No surrounding wells or septics are located within 100' of the proposed system on this lot. 1. Soils: A test hole was performed on this lot by Pannone Engineering Services, LLC in October of 2019. Groundwater was not observed during the excavation of the test hole, and bedrock was not encountered. Groundwater was observed in the test hole monitor tube at a depth of 7.0' on 25 May 2023. Based on the results of the percolation test and overall soils appearance an application rate of 1.2 gpd/SF was used for the design of a conventional wastewater treatment system in the area of the test hole. Groundwater monitoring was performed after installation of drainage improvements on the lot. 2. Soil Absorption System Design. a. See Sheet 1 of the design package. 3. Surface Water: There is no surface water within 100 feet of the proposed septic tank and drain field. 4. Topography: See attached site plan for area topography. 5. Drawing Markings: The Drawings are marked "For MOA Review Only". When written notification that the review is complete and no further comments are received from MoA On -Site Department, the note will be removed and "For Construction" drawings will be issued. The proposed installation will not affect the future development of this or the surrounding lots. If you have any questions or concerns, please contact me at (907) 745-8200. Sincerely, Steven R. Pannone, P.E. F. ASCE Owner/Civil Engineer Mailing: P.O.Box 1807, Palmer, AK 99645 DESIGN PARAMETERS PRIMARY SEPTIC SYSTEM � FIELD COVER NOTE: 15.65 DOES NOT REQUIRE A LIMIT OF N0. BEDROOM: 5(750 gpd) I � FILL BE SHOWN ON THE DRAWING, TANK SIZE: 1500g (MIN) \ HOWEVER, THIS WILL BE AN PERC RATE: 3 MPI �� APPROXIMATE LIMIT OF FILL/COVER. SOIL RATING: 1.2 GPD/SF I LIMIT OF COVER WILL BE FIELD FIT AREA ROD: 625 SF DURING CONSTRUCTION WITH MANY SYS. TYPE: WIDE TRENCH 0.5' ED a ��POSSIBLE VARIABLES. THE FILL MIN LENGTH: 125 LF I � /" \ ALREADY PLACED FOR DEVELOPMENT \ USE: Z \ OF THE LOT (DRIVEWAY/HOUSE) WILL W EFFECT THE LIMIT OF FILL FOR THE L \' (2EA) 70LFx5.0'WxO.5'E.Dx2.0'TD �\ O N DRAINFIELD AND WILL MAKE IT DIFFICULT WITH SAND TO LEVEL TO DIFFERENTIATE BETWEEN FILL TOTAL AREA: 700 SF PLACED FOR DRAINFIELD AND FOR I� 5BR OTHER DEVELOPMENT. PES WILL HOUSE VERIFY MINIMUM COVER IS MET AND \ (P) MAXIMUM SLOPES ARE ADHERED TO AT \ THE TIME OF CONSTRUCTION. I I DOUBLE CLEAN OUT (P) LOCATED NO FURTHER JS THAN 100' FROM HOUSE \ \ RESERVE DRAINFIELD (P) \I 25LF x 5.0'W x 0.5'ED x 2.0'TD ELL P 11�� FILTER SAND AS NECESSARY TO LEVEL I \ INSTALL CLEAN OUT AND MONITOR TUBE AT EACH END 102.4 MOUND TO CREATE 3.0' OF COVER OR INSULATE WITH RIGID INSULATION 3:1 MAX SIDE SLOPE ON MOUND ��5% 1 1500g (MIN) SEPTIC TANK (P) \ (BASED ON CAT III) 1 INSTALL FOUNDATION CLEAN OUT AT BUILDINGS PRIMARY DRAIN FIELD (P) (2EA) 70LF x 5.0'W x 0.5'ED x 2.0'TD FILTER SAND AS NECESSARY TO LEVEL TIE IN AT MIDPOINT OF FIELD INSTALL CLEAN OUT AND MONITOR TUBE AT EACH END MOUND TO CREATE 3.0' OF COVER OR INSULATE WITH RIGID INSULATION 6.0 \ INSTALL DOUBLE CLEAN OUT ON PIPE RUN OVER 100' N—g \ AND DOUBLE CLEAN OUT AFTER 5.0 \ INSULATE IF LESS THAN 4' OF COVER 16.2 INSULATE SEWER LINE UNDER DRIVEWAY `\ ( N P \ \ N I \ GARAGE I 3:1 MAX SIDE SLOPE ON MOUND - DESIGN PARAMETE RESERVE SEPTIC SYSTEM NO. BEDROOM: 5(750 gpd) TANK SIZE: CAT III PERC RATE: 3 MPI SOIL RATING: 6 GPD/SF AREA RQD: 125 SF \\ Nip / V RS �51 (P) \ 90 0 5� I o� I ESTIMATED LIMIT OF COVER (P) \ SEE NOTE APPROX. MOA MAPPED VEGETATED DRAINAGE WAY SYS. TYPE: WIDE TRENCH 0.5' ED \ MIN LENGTH: 25 LF USE: \ \ 30 LFx 5.0' W x O. 5' E. D x 2.0'TD TOTAL AREA: 150 SF - In > \ 3,70 O \ F�SF'�FNT 2 0 NOTES: PAMON LAT!'! CFTC' T T C Date for construction P.O. BOX 100217 ANCHORAGE, AK 99510 1 /2/2024 PHONE (907) 272-8218 FAX (907) 272-8211Scale 1"=50' .... .. P.I.D. NO DRAWN BY: DRM CANYON VIEW ESTATES, BLOCK 1, LOT 8 021-021-41 HULTOUIST HOMES INC. ••even ana PERMIT NO. NSN CANYON ROAD _ CE 8149 osP241000 PLAN ANCHORAGE, AK • •j, Sheet 1 OF 3 SPECIAL PROVISIONS TO SPECIFICATIONS 1. GENERAL NOTES: 1.I' ANY MODIFICATIONS TO THE ATTACHED PLANS NEED TO BE APPROVED BY PES AND THE OWNER OF THE PROPERTY. 1.2. PES SHALL BE NOTIFIED A MINIMUM OF 48 HOURS IN ADVANCE BEFORE CONSTRUCTION OF THE PROPOSED WASTEWATER TREATMENT SYSTEM. 1.3. PES SHALL BE NOTIFIED AM NIMUM OF 24 HOURS IN ADVANCE TO PERFORM A MINIMUM OF FOLLOWING INSPECTIONS: 1.3.1. A PRE CONSTRUCTION MEETING IS REQUIRED BY STATE AND MUNICIPAL REGULATIONS BEFORE A ONSITE WASTEWATER TREATMENT SYSTEM MAY BE INSTALLED. 1.3.2. TOP OF SEPTIC AND OR HOLDING TANK (TANK IS SET IN PLACE LEVEL WITH ALL PIPING ATTACHED (CLEANOUTS, MANHOLES, INLET AND OUTLET PIPING). 1.3.3. BOTTOM OF EXCAVATION OF THE DRAIN FIELD/S. 1.3.4. AFTER PLACEMENT OF FILTER SAND (IF NEEDED). 1.3.5. AFTER INSTALLATION OF THE DRAIN ROCK WITH ALL ASSOCIATED PIPING IN PLACE INCLUDING DISTRIBUTION LINES CLEANOUTS AND MONITOR TUBES PRIOR TO INSTALLATION OF FILTER FABRIC AND INSULATION (IF NEEDED). 1.3.6. FINAL GRADE INSPECTION. ENTIRE SYSTEM IS INSTALLED AND BACKFILLED. 1.4. THE ENGINEER (PES) HAS NO CONTRACTUAL RELATIONSHIP WITH THE CONTRACTOR (THE INSTALLER OF THE SYSTEM) AND, THEREFORE, HAS NO AUTHORITY, CONTROL OR RESPONSIBILITY FOR THE CONTRACTOR'S EMPLOYEES, THE QUALITY OF WORK, THEIR COMPLIANCE WITH THE DESIGN DRAWINGS/SPECIFICATIONS OR THEIR MEANS/METHODS OF CONSTRUCTION. AT APPROPRIATE INTERVALS, THE ENGINEER WILL VISIT THE WORKSITE TO OBSERVE THE QUALITY OF THE CONSTRUCTION AND TO DETERMINE IN GENERAL IF THE CONSTRUCTION IS PROCEEDING IN ACCORDANCE WITH THE DESIGN DRAWINGS/SPECIFICATIONS.THE ENGINEER WILL NOTIFY THE OWNER IF DEFICIENCIES ARE OBSERVED; HOWEVER, THE FAILURE OF THE ENGINEER TO OBSERVE A DEFICIENCY WILL NOT RELIEVE THE CONTRACTOR OF THE RESPONSIBILITY FOR CORRECTING ANY SUCH DEFICIENCY. THE ENGINEER WILL PREPARE RECORD DRAWINGS AND SUBMIT THEM TO THE REGULATORY AGENCY HAVING JURISDICTION OVER THE WASTEWATER TREATMENT SYSTEM (ADEC OR MOA). FINAL APPROVAL OF THE WORK AND CORRECTION OF ANY DEFICIENCIES IS BETWEEN THE OWNER, THE CONTRACTOR, AND THE REGULATORY AGENCY HAVING JURISDICTION OVER THE WASTEWATER TREATMENT SYSTEM (ADEC OR MOA). 2. SCOPE AND SPECIFICATIONS: 2.1. ALL CONSTRUCTION SHALL BE INSTALLED AS SPECIFIED IN THE MOST CURRENT EDITION OF THE MOA COMPONENT PARTS AND MATERIALS USED IN CONSTRUCTION OF ON -SITE WASTEWATER DISPOSAL SYSTEMS AND AND IN ACCORDANCE WITH AMC 15.65 AND 15.55. 2.2. CONTRACTED WORK WILL BE IN COMPLIANCE WITH MUNICIPALITY OF ANCHORAGE STANDARD SPECIFICATIONS (MASS) DIVISION 10 & DIVISION 20 AS APPROPRIATE. 2.3. SCOPE OF WORK: INSTALL SYSTEM PER DESIGN 2.4. GROUNDWATER WAS NOT ENCOUNTERED TO A DEPTH OF 7.0 FEET BELOW EXISTING GRADE AS EVIDENCED BY THE SOIL TEST HOLE. IF AN APPARENT WATER TABLE IS OBSERVED IN ANY OF THE EXCAVATIONS LESS THAN 7.0 FEET BELOW EXISTING GRADE NOTIFY THE ENGINEER IMMEDIATELY. 2.5. STRUCTURES DEPICTED ON THE SITE PLAN AR BASED UPON ONE OF THE FOLLOWING: CONCEPTUAL PLOT PLAN DEVELOPED BY OWNER; A PLOT PLAN DEVELOPED BY RLS; OR A SURVEY AS -BUILT. 3. CONSTRUCTION SPECIFICATIONS: 3.1. ALL EXCAVATION DEPTHS ARE ADVISORY. THEY ARE TO BE VERIFIED AND MAY BE MODIFIED BY THE ENGINEER IF ACTUAL FIELD CONDITIONS VARY FROM THOSE USED TO PREPARE THE DESIGN 3.2. EXCAVATE THE DRAIN FIELD. BOTTOM OF EXCAVATION SHALL BE LEVEL AND SCARIFIED. RECORD ELEVATIONS AT BEGINNING, MIDDLE AND END OF TRENCH BOTTOM. CONSTRUCTION EQUIPMENT SHALL NOT OPERATE ON THE FLOOR OF THE EXCAVATION. ANY MATERIAL COMPACTED BY THE OPERATION OF THE CONSTRUCTION EQUIPMENT SHALL BE REMOVED AND REPLACED WITH UNCOMPACTED MATERIAL. 3.3. PLACE THE SEWER ROCK TO THE SPECIFIED DEPTHS. DO NOT CONTAMINATE SEWER ROCK WITH NATIVE MATERIAL OR SPOILS FROM EXCAVATION. LEVEL ROCK SURFACE TO ±1" PRIOR TO INSTALLING THE PERFORATED PIPE. 3.4. ALL PIPE SHALL BE PVC CONFORMING TO ASTM D3034 OR ENGINEER APPROVED EQUAL. MINIMUM SOIL COVER SHALL BE 3 FEET OVER THE PIPE AND 4 FEET OVER THE SEPTIC TANK. ONE INCH OF INSULATION MAY BE SUBSTITUTED FOR i FOOT OF SOIL COVER. 3.5. ALL INSULATION SHALL BE 2" THICK DOW HI-40 INSULBOARD OR ENGINEER APPROVED EQUAL. CENTER INSULBOARD WIDTH OVER SEPTIC TANK OR LINES. 3.6. GEOTEXTILE SHALL BE MIRAFI 140S OR ENGINEER APPROVED EQUAL. LAP ALL JOINTS 2 FEET MINIMUM. 3.7. COVER THE DISTRIBUTION PIPE WITH A MINIMUM OF 2" OF SEWER ROCK AND COVER WITH GEOTEXTILE BEFORE PLACING INSULATION AND BACKFILL. 3.8. MATERIAL USED AS FILL SHALL BE CLEAN AND FREE OF ORGANICS, TRASH AND CONSTRUCTION DEBRIS. 3.9. SLOPE ALL FILL MATERIAL TO DRAIN AT 2% MINIMUM SLOPE AND 3:1 MAXIMUM SLOPE AND IN SUCH A MANNER THAT PONDING AT OR NEAR THE DRAIN FIELD DOES NOT OCCUR. THE FILL SHALL BE LEFT AT 6" HIGHER THAN SHOWN TO ALLOW FOR SETTLEMENT. SEED SURFACE AFTER COMPLETING INSTALLATION AS PER MOA CODE. 3.10. RECORD THE FINISH GROUND ELEVATION OVER THE BEGINNING, MIDDLE AND END OF SYSTEM. 3.11. MAINTAIN 5' SEPARATION BETWEEN PERCOLATION HOLE AND THE DRAIN FIELD TRENCH. 3.12. EXPOSE, PUMP AND FILL LOG DISPOSAL CRIB OR CONCRETE TANK WITH SOIL TO ABANDON IAW WITH MOA CODE IF NEEDED. 4. CONTRACTOR RESPONSIBILITIES: 4.1. THE CONTRACTOR SHALL FAMILIARIZE THEMSELVES WITH THE SITE CONDITIONS AND LOCATIONS OF ALL LOT LINES, EASEMENTS, WELLS (E & P), SEPTIC SYSTEMS (E & P) AND SHALL MEET MINIMUM SEPARATION DISTANCES OR AS NOTED. 4.2. THE CONTRACTOR (BOTH WELL AND SEPTIC SYSTEM CONTRACTORS) SHALL HAVE ANY WELL LOCATION AND SEPTIC LOCATION STAKED AND ANY LOT LINE AND WELL RADIUS SHOWN ON THE PLAN WITHIN 30 FEET OF THE PROPOSED SYSTEM STAKED BY A REGISTERED LAND SURVEYOR BEFORE STARTING THE WORK. 4.3. THE CONTRACTOR IS RESPONSIBLE FOR ALL R.O.W. AND OTHER REQUIRED PERMITS, OTHER THAN THE ATTACHED. 4.4. THE CONTRACTOR SHALL CALL FOR LOCATING OF ALL BURIED UTILITIES. 4.5. THE CONTRACTOR SHALL PROVIDE 24 HOUR NOTICE TO THE ENGINEER PRIOR TO START OF WORK. ALL SURVEYING AND LOCATES SHALL BE IN PLACE PRIOR TO NOTIFYING THE ENGINEER. 4.6. THE CONTRACTOR SHALL NOTIFY THE ENGINEER OF ANY DISCREPANCY BETWEEN THE APPROVED DRAWINGS AND SITE CONDITIONS/LIMITATIONS POTENTIALLY CAUSING THE NEED TO MODIFY THE DESIGN. 4.7. AT THE COMPLETION OF THE WORK, THE CONTRACTOR SHALL SUBMIT RED -LINE AS -BUILT DRAWINGS TO THE ENGINEER. THE RED -LINES SHALL INCLUDE PIPE LENGTHS, ORIGINAL GROUND ELEVATIONS, PIPE ELEVATIONS, AND TANK ELEVATIONS. 4.8. THE CONTRACTOR SHALL PROVIDE PHOTOGRAPHS OF THE SYSTEM INSTALLATION TO INCLUDE BOTTOM OF EXCAVATION, TOP OF PIPE WITH CLEAN -OUTS AND MONITOR TUBES INSTALLED, INSTALLED TANK AND FINAL GRADING. 5. THE CONTRACTOR SHALL SIGN THE FOLLOWING: I CERTIFY THAT ALL WORK WILL BE PERFORMED IN ACCORDANCE WITH THE APPROVED PERMIT, AND ANY AND ALL CHANGE ORDERS, AND THAT THE AS -BUILT REDLINES ARE TRUE AND ACCURATE REPRESENTATION OF THE PROJECT AS CONSTRUCTED. THE PARTIES HEREBY AGREE TO THE TERMS AND CONDITIONS SET FORTH IN ATTACHED DOCUMENTS. CLIENT: CONTRACTOR: NAME: NAME: SIGNATURE: SIGNATURE: DATE: DATE: PLy1V1�lONE L'1�1V' �C� LLC Date for construction 1 /2/2024 P.O. BOX 100217 ANCHORAGE, AK 99510 ••••. PHONE (907) 272-8218 FAX (907) 272-8211 �P �••• •�'•, Scale *�•�m `�* NITS ....•• •• •••• P.I.D. NO CANYON VIEW ESTATES, BLOCK 1, LOT 8 021-021-41 HULTQUIST HOMES INC. •• �ev� anrio�a PERMIT No. CE 8149 NSN CANYON ROAD OSP241000 DESIGN DETAILS ANCHORAGE, AK ••j, Sheet 2OF3 TH8 SOILS LOG - PERCOLATION TEST 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 OR I TOPSOIL GM/SM I SILTY SANDY GRAVEL SM/ML I SILTY SANDY GRAVEL BOH DATE PERFORMED: 030CT19 NO GROUNDWATER: 11OCT19 SLOPE TEST HOLE WAS GROUND WATER ENCOUNTERED? N IF YES, AT WHAT DEPTH? -NA- DEPTH TO WATER AFTER MONITORING? DRY DATE: 11 OCT19 DEPTH TO WATER AFTER MONITORING? -0.0' DATE: 27MAY20 DEPTH TO WATER AFTER MONITORING? -7.0' DATE: 25MAY23 COMMENTS: Test hole excavated by WHITE RAVEN PERFORMED BY: AARON PARADIS. I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDLINES IN EFFECT ON THE DATE SITE PLAN SLOPE TH 1 SOIL TEST RESULTS/ANALYSIS • PERCOLATION RATE 3.0 mpi(min/inch) (Hydrologic Soils Group: HSG A) • PERC HOLE DIAMETER 6" • TEST RUN BETWEEN 2 FT AND 3 FT. • TEST RUN FOR OVER AN HOUR, LAST THREE READINGS PROVIDED. 2023 GROUNDWATER MONITORING PERFORMED AFTER DRAINAGE INFRASTRUCTURE INSTALLED ON LOT. READING DATE NET TIME WATER LEVEL READING NET DROP R E RATI) 1 030CT19 5.900" 2 10 MIN 9.902" 4.002" 2.5 3 5.900" 4 10 MIN 9.250" 3.35" 5 5.900" gO 6 10 MIN 9.221" 3.321" NOTES: PAMONE ENG SVC LLC Date for construction P.O. BOX 102954 ANCHORAGE, AK 99510 �..., 1/2/2024 PHONE (907) 272-8218 FAX (907) 272-8211P••• Scale NTS .... .. ....... P.I.D. NO CANYON VIEW ESTATES, BLOCK 1, LOT 8 021-021-41 HULTQUIST HOMES INC. ;ems ana PERMIT No. NSN CANYON ROAD CE 8149.�' osP241000 SOILS LOG ANCHORAGE, AK Sheet 3OF3 MUNICIPALITY OF ANCHORAGE Development Services Department f Phone: 907-343-7904 On -Site Water & Wastewater Section —� Fax: 907-343-7997 Certificate of On -Site Systems Approval Parcel I.D. 021-021-41-000 Expiration Date: Legal description CANYON VIEW ESTATES BLK 1 LT 8 Site address 13801 CANYON RD Anchorage AK 99516 Current property owner(s) HULTQUIST HOMES INC 10/16/2025 X The On-site system(s) is/are approved for 5 bedrooms Conditional approval for bedrooms, with the following stipulations: Comments or advisories: QI Original Certificate Date: 11/1/2024 Tis Certificate of On -Site Systems Approval (COSA) is intended to demonstrate the subject system(s) is/are in substantial compliance with municipal code. The Municipality of Anchorage, Development Services Department (DSD) issues COSAs based upon representations provided by an independent professional engineer. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. ATTACHMENTS: COSA Checklist X Well Flow Advisory Absorption Field Advisory Nitrate Advisory Tank Age Advisory Arsenic Advisory Other COSA Approval_June 2022 MUNICPAL111TY OF ANCHORAGE RU5 ki Development Services Department Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Certificate of On -Site Systems Approval Application 1. GENERAL INFORMATION Parcel I.D. 021-021-41 Complete legal description Canyon View Estates 131 L8 Location (site address) 13801 Canyon Road Current property owner(s) Hultquist Homes 2. ON-SITE SYSTEMS SIZED FOR 5 BEDROOMS Day phone 3. TYPE OF WATER SUPPLY: 0 Private Well ❑ Private Well serving 2 dwelling units ❑ Private Well serving 3+ dwelling units ❑ Community Well or Public ❑ Water Storage 4. TYPE OF WASTEWATER DISPOSAL: ❑■ Private Septic ❑ Private Septic serving 2 dwelling units ❑ Holding Tank ❑ Community Septic or Public Sewer 5. SEPTIC TANK: ❑ Steel ■❑ Plastic ❑ Concrete ❑ Fiberglass Age new - See advisory if steel older than 20 years 6. ABSORPTION FIELD: ❑ AWWTS ❑ Bed ❑ Deep Trench ❑ Wide Trench ❑ Seepage Pit Waiver request for: Expedited review requested: ❑■ Distance: By applying for this entitlement, this property is subject to inspection by municipal On-site staff to verify the accuracy of the information provided. COSA Fee $-1/1-0 Waiver Fee $ Date of Payment COSA# 0,'5:j: i,.2�-IIS 5b Date of Payment Waiver # COSA Applicationjune 2022 COSA Checklist_June 2022 COSA Checklist Legal Description: Parcel ID: If more than 1 well and/or septic system on lot, provide separate checklist. Structure served by this system ____ A. WELL DATA Well log is filed with Onsite (or attached) Date drilled Total depth ft Cased to ft Sanitary seal is functioning correctly Wires are properly protected Casing height (above ground) in. Date of flow test for COSA Static water level at beginning of test ft. Well production at time of test gpm Water storage tank volume gallons Well disinfected for coliform test? Yes No Coliform bacteria is Negative Nitrate mg/L Nitrate less than MRL (ND) Arsenic ug/L Arsenic less than MRL (ND) Collected by Date Comments __________________________________________________________________________________ B. TANK DATA Measured operating fluid level in septic tank Date of pumping Required maintenance completed, if AWWTS Comments: C. LIFT STATION Required maintenance completed Age of lift station years Lift station material Comments: D. ABSORPTION FIELD DATA Which system tested (date installed) ALL standpipes present per record drawing Total measured depth from grade ft (max) Measured depth to pipe invert from grade ft (min) N/A – pressurized field. Per record drawings, field is insulated. Monitor tubes go to bottom of effective. If not, state depth into effective Presoaked required if (Required if house vacant or field not used for more than 30 days prior to date of test) Gallons introduced gallons date Any rejuvenation treatment (past 12 months) If yes, enter date Adequacy test date Results Pass Fluid depth prior to test in Water added gal New fluid depth in Elapsed time min Final fluid depth in Absorption rate gpd FIELD STATUS – POST RECOVERY Effective depth (per record drawings) in Effective depth used in Effective depth remaining in Comments/Deficiencies: COSA Checklist_June 2022 E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well on lot) Septic Tank/Lift Station on Lot > 100’ Yes if No ft Neighboring Tank > 100’ Yes if No ft Absorption Field on Lot > 100’ Yes if No ft Neighboring Absorption Fields > 100’ Yes if No ft Community Sewer Main > 75’ Yes if No ft Community Sewer Manhole/Cleanout > 100’ Yes if No ft Private Sewer/Septic Line > 25’ Yes if No ft Holding Tank > 100’ Yes if No ft Animal Containment > 50’ Yes if No ft Manure/Animal Excreta Storage > 100’ Yes if No ft N/A – Served by Community Well (not on lot) or Public Water From Septic/Holding Tank and Absorption Field(s) on Lot to: (Please enter distances if less than required) Building Foundations > 10’ Yes if No ft Tank to Property Line > 5’ Yes if No ft Field to Property Line > 10’ Yes if No ft Water Main > 10’ Yes if No ft Water Service Line > 10’ Yes if No ft Surface Water > 100’ Yes if No ft Wells on Adjacent Lots: Private Wells > 100’ Yes if No ft Community Wells > 200’ Yes if No ft If tank or field is under driveway comment below F.ENGINEER’S COMMENTS G.CERTIFICATION & STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines, indicates that the on-site water supply and/or wastewater disposal system appears to comply with applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation, unless noted otherwise. In conducting an adequacy test, I attempt to provide a thorough, conscientious engineering analysis of the system in accordance with ADEC & MOA guidelines and regulations. The reported results describe the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soil condition, ground water levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of this system. All systems eventually fail, and satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. Therefore, we cannot provide any warranty for future performance, nor can we estimate remaining life of the system. The content of this report is for the sole benefit of the owner listed above. Name of Firm Phone Engineer’s Printed Name Date 2024.10.29 Lot 8, Block 1, Canyon View Estates Subdivision As-Built Land Surveying Land Development Consultants Subdivision Specialists Construction Surveying AEC# 173042 S4 Group 124 E 7th Avenue Anchorage, Alaska 99501 (907) 306-8104 mail@S4AK.com 07/22/2024