HomeMy WebLinkAboutT15N R1E SEC 1 S2NE4NE4SW4Onsite File T15N RIE SEC I Municipality of Anchorage On -Site Water and Wastewater Section • (907) 343-7904 Page 1 of 1 ON -SITE WASTEWATER INSPECTION REPORT Permit Number: OSP PID Number: 057-061-04 Dwelling: 0 Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: 0 Nevy ❑ Upgrade Name KELLER ABSORPTION FIELD F0 Deep Trench ❑ Wide Trench ❑ Bed ❑ Mound Site Address 36784 EKLUTNA LAKE RD ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 5 1.1 GPD/SF 10 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade 5 0 Ft Gravel depth beneath pipe 5 0 Subdivision Block Lot T15N R1E SEC 1 S2NE4NE4SW4 Ft. Fill added above original grade 0 Ft. Gravel length 83 Ft. Township Range Section Grave! width 3.0 Ft. Beds: Number of Lines 0 Distance between lines SEPARATION DISTANCES To Septic Absorption Holding Sewer Lift Station Total absorption area Number of trenches Ft. Dist. between trenches From Tank Field Tank Line 830 Ft2 Ft. Well 100'+ 100'+ 50'+ ITANK ®Septic ❑ S.T.E.P. ❑Holding D Other Manufacturer Capacity Surface Water 100'+ 1 00'+ GREER/ANCH TANK 1500 Gal. Material Number of compartments Lot Line 1 0'+ 1 0'+ NA PLASTIC 2 Foundation 10'+ 10'+ LIFT STATION Manufacturer Capacity Remarks Gal. Alarm location Electrical instpiled by Installer PIPE MATERIAL House to tank 3034 ' Tank to 3034 drainfield UNKNOWN Drainfield 3034 CO/MT3034 Inspector MIKE N ANDERSON PE BENCH MARK (Assumed elevation) 106.4 ft Inspection 1" 7/19/23 2nn 7123/23 Location and description 3`d 4`" TOP OF MH LID ON -SITE WATER AND WASTEWATER SECTION APPROVAL Enginee ,s Stamp O A� Conditional Approval- Date ;... > > , .�i � • OF 1 �dd Septic System Approved Date 3 2� z y MICHAEL N. ANDLRoC;d , � ,�. CE - 9469 . f• Note: this approval does not include well permit requirements. Pnt' ȭ Mike 02/14/24 Test pumping and camera results: Well sta�c was at 101’ draw down was 104’ at 6 gpm Recovery back to 101’ in 45 sec. = 14 gpm camera results: Well is cased 50’ plus no breaks or perfora�ons found Thanks Johnny Kay He�y Drilling, Inc. MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program ti° Spa PO Box 196650 4700 Elmore Road i. Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 �w http://www.muni.org/onsite Depal-ttttelit On -Site Water & Wastewater System Permit Permit Number: OSP241030 Effective Date: 3/5/2024 Work Type: WellSeptic Initial Expiration Date: 3/5/2025 Tax Code Number: 05706104000 Site Legal Address: T15N R1 E SEC 1 S2NE4NE4SW4 G:1410 Site Mailing Address: 36784 EKLUTNA LAKE RD, Chugiak Owner: KELLER GLEN & MARY FAMILY Lot Size in Sq Ft: 217800 Design Engineer: ANDERSON MICHAEL Total Bedrooms: 5 This permit is for the construction of: ✓Q Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy Q Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Received By: Issued B Y= /�1 14 Date: Date: `( �" d----- 3 .C-�_�ZL... March 1, 2024 Municipalities of Anchorage Development Services Dept. On-Site Water & Wastewater Section Anchorage, Alaska 99519 Phone 343-7904 Re: Septic & well testing Legal: T15N R1E SEC 1 S2NE4NE4SW4 To Whom it may concern: This is a request for a COSA on the above referenced lot, which is undocumented. The existing system appears to have been originally installed in the mid 1990’s but the tank was upgraded in the last year, per the owner. Two test holes were excavated and found 18 & 16 feet of poorly graded sands and gravels (SP/GP) to the bottom of the test holes. No water was observed during the excavation or after the 7-day monitoring period. The existing trench had five feet of effective in the existing trench. The tank consisted of a 1500 gallon plastic tank from Greer Tank with the standard 20 inch riser. The leach field was dry prior to the test, then raised four inches during the test. The well was investigated by Hefty Drilling and found the static level at 101 feet. The flow rate was measured at greater than 5 gpm and the casing was verified greater than 50 feet, see note from Hefty Drilling This septic system and well will not impact any of the surrounding neighbors due to the excellent soils and very large lots. Sincerely Michael N. Anderson, P.E. 4661 Natrona Anch, Ak 99516 Ph 727-8864 Municipality of Anchorage L) Development Services Department ..� .. • • • ; ;.:, On -Site Water and Wastewater Section 4700 Elmore St. `„�,, P.O. Box 196650 Anchorage, AK 99519-6650 4. g T Ii $, '.• ; ', wwo.muni.orgftinsile (907) 343-7904 �. ;• .......... • • e ........ r` ; ...................... Soils Log - Percolation Test Performed For: Z•1 vC ✓1 Date Performed:°? - Legal Description: St c Township, Range, Section: Depth+� 1- 2- 3- 4- 5- �pJtiC/ 6- l 7- 8- �u (� •tJ�i r 9- 10- 11- 12- 13- 14- 15- 16- �v t{v�✓+, 17- 18- 19- 20- C�i�7T,J,Til�.lf11� Site Plan -�p WAS GROUND WATER ENCOUNTERED? t �+ D S IF YES, AT WHAT DEPTH? L Depth to Water After iMonitoring?E o Date: (t/ Reading Date Gross Time Net Time Depth to Water Net Drop " Zk I,'t Kk-ULAI TUN KAI t '�o tminutesfinch) !! PERC HOLE DIAMETER TEST RUN BETWEEN _5- FT AND LA FT PERFORMED BY: 1`--i NJ t I CERTIFY THAT THIS TEST WA PERFORMED IN ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: Zt ? Municipality of Anchorage`— �`\ • Development Services Department On -Site Water and Wastewater Section „���;•' ' �; ' rH .' ° •,� y, <+ 4700 Elmore St. 9 { P.O. Box 196650 Anchorage, AK 99519-6650 (907) 343-7904 a ... ............ , Soils Log - Percolation Test �, x%T7`�`f p�r✓"", Performed For:, t� r r` Date Performed: Legal Description: T( S-n y Township, Range, Section: Depth r%—r 2- 4- 5- 6- c, P 7- GX,e. 9- WAS GROUND WATER ENCOUNTERED? /LLV 10- S IF YES, AT WHAT DEPTH? L 1 1- Depth to Water After O Monitoring? E 12- Date: 13- 14- 15- 16- 17- 0 20- Sites Plan N Reading Date Gross Time 7 Net Time Depth to Water Net Drop !j 7I t! �ri lJ 2 It o�onnn --- - - - - -- —. - . - •. •- -, mw "u j rtKG HULL UTAMETER L/ ri TEST RUN BETWEEN __�_FT AND _ � FT COMMENTS t v {.t r — '�`' PERFORMED BY: A!f j A, I CERTIFY THAT THIS TEST W S PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: Z -Z a Page:1 Anchorage Tank 2723 Rampart Dr Anchorage, AK 99501 Phone: 907-272-3543 Fax: 907-277-3715 www.anchoragetank.com 0010056 8/3/2023Date: Invoice Number: Invoice Billed To:Gene Keller 36784 Eklutna Lake Rd Chugiak, AK Gene Keller 36784 Eklutna Lake Rd Chugiak, AK Net 30 Shipped To: Terms:Ship Via:Purchase Order #: Due Date:9/2/2023 WHSE:Main Warehouse FOB: CHECKPayment Type: Qty DescriptionUnit Price Ext Price 1500 Poly Septic Tank MOA 4' R $4,920.00 $4,920.00EACH1 RISER/TANK ADAPTER,24" ABS NEW $0.00 $0.00EACH1 COUPLING, SEPTIC, 5 X 4 $0.00 $0.00EACH2 COUPLING, SEPTIC, 4 X 4 $0.00 $0.00EACH1 RISER 4ft, 4" Insulation $0.00 $0.00EACH1 MA320 GLUE PACKET $0.00 $0.00EACH2 RISER/TANK ADAPTER, 24" ABS $0.00 $0.00EACH1 1500 Poly Septic 102Lx78Wx77H $0.00 $0.00EACH1 Serial Number: 1.0001906 Sikaflex 15ml 10 oz $0.00 $0.00EACH2 PVC, PIPE, 4" 3034 $4.50 $450.00FT100 5,370.00Invoice Balance: Past due balances are subject to a service charge of .875% Monthly or up to (10.5% Annual) or the maximum allowed by State of Alaska usury laws. 15% Restock Fee No return on electrical parts. On-line payment available. Click "Bill Pay" button on our web site. www.anchoragetank.com 5,370.00Invoice Total: Parcel I.D. 057-061-04 Certificate of On -Site Systems Approval Expiration Date:I�� Legal description T15N R1 E SEC 1 S2NE4NE4SW4 Site address 36784 EKLUTNA LAKE RD Chugiak AK 99567 Current property owner(s) KELLER GLEN & MARY FAMILY TRUST X The On -site system(s) is/are approved for 5 bedrooms Conditional approval for bedrooms, with the following stipulations: Comments or advisories: F-( r� L-17) r,S F_ a i 9 9w 's 1 By Original Certificate Date: 3/5/2024 This Certificate of On -Site Systems Approval (COSA) is intended to demonstrate the subject system(s) is/are in substantial compliance with municipal code. The Municipality of Anchorage, Development Services Department (DSD) issues COSAs based upon representations provided by an independent professional engineer. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. ATTACHMENTS: COSA Checklist X Well Flow Advisory Absorption Field Advisory Nitrate Advisory Tank Age Advisory Arsenic Advisory Other COSA Approval —June 2022 MUNICIPALITY OF ANCHORAGE Development Services Department�'�.T Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Certificate of On -Site Systems Approval Application 1. GENERAL INFORMATION Parcel I.D. 057-061-04 Complete legal description Location (site address) T15N R1 E SEC 1 S2NE4NE4SW4 36784 EKLUTNA LAKE RD Current property owner(s) GENE KELLER 2. ON -SITE SYSTEMS SIZED FOR 5 BEDROOMS Day phone 3. TYPE OF WATER SUPPLY: ❑■ Private Well ❑ Private Well serving 2 dwelling units ❑ Private Well serving 3+ dwelling units ❑ Community Well or Public ❑ Water Storage 4. TYPE OF WASTEWATER DISPOSAL: [W Private Septic ❑ Private Septic serving 2 dwelling units ❑ Holding Tank ❑ Community Septic or Public Sewer 5. SEPTIC TANK: ❑ Steel 0 Plastic ❑ Concrete ❑ Fiberglass Age 2 - See advisory if steel older than 20 years 6. ABSORPTION FIELD: ❑ AWWTS ❑ Bed Deep Trench ❑ Wide Trench ❑ Seepage Pit Waiver request for: Expedited review requested: 0 Distance: By applying for this entitlement, this property is subject to inspection by municipal On -site staff to verify the accuracy of the information provided. COSA Fee $ 1� Waiver Fee $ Date of Payment Z / 2(-%70'Zcy COSA # os GZy l j Date of Payment Waiver # COSA Application_ June 2022 COSA Checklist Legal Description: T15N R1 E SEC 1 S2NE4NE4SW4 Parcel ID: 057-061-04 If more than 1 well and/or septic system on lot, provide separate checklist. Structure served by this system _ A. WELL DATA ❑ Well log is filed with Onsite (or attached) Date drilled 'UN Total depth >101 ft Cased to 50+ ft Sanitary seal is functioning correctly ❑ Wires are properly protected Casing height (above ground) 16 in. Date of flow test for COSA 2/14/24 Well production at time of test 5+ gpm Water storage tank volume 0 gallons Well disinfected for coliform test? ❑ Yes No I Coliform bacteria is Negative Nitrate 0.336 mg/L ❑ Nitrate less than MRL (ND) Arsenic ug/L N Arsenic less than MRL (ND) Collected by MNA Static water level at beginning of test *101 ft. Date 8/28/23 Comments " DATA FROM HEFTY DRILLING SEE ATTACHED EMAIL [ARC12I:41173/_1 Measured operating fluid level in septic tank 70 Date of pumping 8/28/23 ❑ Required maintenance completed, if AWWfS Comments: D. ABSORPTION FIELD DATA Which system tested (date installed) 2/23/24 101 ALL standpipes present per record drawing Total measured depth from grade 10 ft (max) Measured depth to pipe invert from grade 5 ft (min) ❑ N/A — pressurized field. ❑ Per record drawings, field is insulated. 0 Monitor tubes go to bottom of effective. If not, state depth into effective _ ❑ Presoaked required if (Required if house vacant or field not used for more than 30 days prior to date of test) Gallons introduced gallons date Any rejuvenation treatment (past 12 months) If yes, enter date Comments/Deficiencies: COSA Checklist June 2022 C. LIFT STATION ❑ Required maintenance completed Age of lift station _ years Lift station material Comments: Adequacy test date 8/28/23 Results RPass Fluid depth prior to test 0 in Water added 750 gal New fluid depth 4 in Elapsed time 1440 min Final fluid depth 0 in Absorption rate 750 gpd FIELD STATUS — POST RECOVERY Effective depth (per record drawings) '60 in Effective depth used 0 in Effective depth remaining 60 in E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well on lot) Septic Tank/Lift Station on Lot > 100' Community Sewer Manhole/Cleanout > 100' Q Yes if No _ ft [E Yes if No _ ft Neighboring Tank > 100' ❑m Yes if No _ ft Private Sewer/Septic Line > 25' 0 Yes if No _ ft Absorption Field on Lot > 100' [E Yes if No _ ft Holding Tank > 100' U Yes if No _ ft Neighboring Absorption Fields > 100' Animal Containment > 50' Q Yes if No _ ft ❑i Yes if No ft _ Manure/Animal Excreta Storage > 100' Community Sewer Main > 75' Yes if No _ ft Q Yes if No _ ft ❑ N/A— Served by Community Well (not on lot) or Public Water From Septic/Holding Tank and Absorption Field(s) on Lot to: (Please enter distances if less than required) Building Foundations > 10' ❑� Yes if No _ ft Surface Water > 100' 0 Yes if No _ ft Tank to Property Line > 5' Field to Property Line > 10' Water Main > 10' Water Service Line > 10' F. ENGINEER'S COMMENTS QYes ifNo_ft ❑N Yes if No _ ft ❑� Yes if No _ ft ❑� Yes if No _ ft Wells on Adjacent Lots: Private Wells > 100' Community Wells > 200' ❑� Yes', if No _ ft ❑� Yes if No _ It If tank or field is under driveway comment below G. CERTIFICATION & STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines, indicates that the on -site water supply and/or wastewater disposal system appears to comply with applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation, unless noted otherwise. Name of Firm Mt tt C A A. d, 'P/ t Phone 727-8864 Engineer's Printed Name C v� e_, Date 3 t OF, 00 ............. ........ , �•A • MICHAEL N. ANbILRSCN �• COSA Checklist June 2022 ///////// /// // / \\ \ / / / /// // / /// /// /// // / 32.2' 32 . 4 ' 16.4' 47 . 8 ' 52 . 0 ' 16.0' 2. 0 ' 44.0' 26 . 2 ' 75.8'S1/2, NE1/4, NE1/4, SW1/4 WORK ORDER No:DATE:SCALE: DRAWN: ROL CHECKED: ROL ZONING: 1"=50'Feb 29, 2024 CER-10 SL GRID No:FB BOOK/PAGE: NE1410 C757 SURVEY CERTIFICATION: FARPOINT has conducted a physical survey of the subject property, the improvements situated thereon are within the property lines as shown. EXCLUSION NOTES: It is the owners responsibility to determine the existence of any easements, covenants, or restrictions which do not appear on the Plat used for this survey. NOTE: Under no circumstances should any data hereon be used for construction or for the establishing of property lines. PREPARED FOR: Mike Anderson ASBUILT SURVEY OF: Found Alcap Cleanout Well Farpoint Land Services, LLC SURVEYING, MAPPING, LAND PLANNING, GIS 1131 E. 76th Ave., Suite 101 Anchorage, Alaska 99518 FarpointAK.com (907) 522-7770 survey@farpointak.com Robert O. Lumpkin No. 10459 R E GISTEREDPROFESSIO N A L L A N D S U RVEYOR SERVI N G A L A SKA SI N C E 1 9 8 2 Unsubdivided: S1/2, NE1/4, NE1/4, SW1/4, T15N, R1E, Section 1, Eklutna, Alaska 1.Bearings and distances are record per referenced plat unless otherwise noted. 2.Not all monumentation for this survey may be shown on this document. 3.Excepting for gross negligence, the liability for this survey shall not exceed the cost of preparing this survey. 4.Property Address is 36784 Eklutna Lake Road, Anchorage, AK 99567 5.Due to snow coverage, all features might not be located this survey. 2/29/'24