July 15, 2022 VIA EMAIL
BENJAMIN & REBEKAH GARNETT
9800 BASHER DRIVE
ANCHORAGE, AK 99507
RE: STUCKAGAIN HEIGHTS ADD 3 BLOCK 3, LOT 5A – ANCHORAGE, AK
WASTEWATER SYSTEM REPORT
Per your request, we have evaluated the above subject properties by conducting a site visit, review of
existing soils, groundwater analysis, MOA design, and review of adjacent properties along with MOA
documents to ascertain the feasibility of the lots to support onsite water and wastewater systems. Per this
investigation, it is determined that the lots of the proposed plat can and do support on-site water systems
and conventional wastewater systems and if needed will support advanced wastewater systems per
Municipality of Anchorage (MOA) On-Site water and wastewater codes. This investigation was based on
MOA AMCC15.65.410 Subdivision Standards and observations of the day in which the evaluation or
testing were performed and according to available MOA on-site record documents.
The slopes found on site were as described and permitted (MOA SW070176) per the existing design that
was reviewed in the MOA file. An existing conventional permitted MOA system appears to be adequate
to serve the proposed structure, but would need to be renewed with the MOA and most likely a new plot
plan or lot layout with the proposed house. An advanced wastewater system could be used too and would
be a Category III system (i.e. Advantex) with well setback separation requirements of 50’ and other
separation reductions from a typical conventional wastewater system.
The assessment of the condition of the lots applies only to the conditions as of the days inspected and per
visual observations. Various and dynamic characteristics of subsurface conditions that may not be
observed from the surface, changes in land use, local soil characteristics, groundwater levels that may
fluctuate during the year are outside the control of the evaluator of the lots and no guarantee can be given
that no unseen encroachments, deficiencies or discrepancies exist.
STUCKAGAIN HTS. B3 L5
July 15, 2022
Page 2 of 2
However based on this investigation, it appears that the lots can support on-site wells with either
conventional wastewater / septic systems or advanced wastewater systems. Based on this investigation,
which was completed in compliance with state and municipal regulations and industry standards, I have
certified the adequacy of this site. If after review of these records you or any of the underwriters have any
questions regarding this site or the procedures employed during our evaluation, please feel free to contact
us at (907-350-9566) or via email at FirstWaterAK@gmail.com.
Respectfully,
Curtis Huffman, P.E.
Attachments: FWC Suitability
FWCS Invoice
FIRST WATER CONSULTING
STUCKAGAIN HTS. ADD.4 B3, LOTS 5B & 6B
WATER & WASTEWATER SITE SUITABLITY: