HomeMy WebLinkAboutCANYON VIEW ESTATES BLK 2 LT 7• z #0 2 1 am 0 %A%R (Rev 05/02/18) Municipality of Anchorage On -Site Water and Wastewater Section • (907) 343-7904 Page 1 of 2 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP241049 PID Number: 021-021-53 Dwelling: 0 Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: R New ❑ Upgrade Name Hultquist Homes, Inc. ABSORPTION FIELD ❑ Deep Trench ❑Q Wide Trench El Bed ❑Mound Site Address 13852 Canyon Road ❑ Other Phone Number of Bedrooms Soil Rating depth from original grade 4 1.2 GPD/SF JTotal 6.0 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade 4.0 Ft. Gravel depth beneath pipe 2.0 Ft. Subdivision Block Lot Canyon View Estates 2 7 Fill added above original grade 0.3 Ft. Gravel length 70 Ft. Township Range Section Gravel width 5.0 Ft. Beds: Number n/a of Lines Distance between lines n/a Ft. SEPARATION DISTANCES To Septic Absorption Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Lift Station Tank Line 500 Ftz 1 n/a Ft. Well 100'+ 100'+ NA NA 25'+ TANK X Septic ❑ S.T.E.P. ❑ Holding ❑ Other Manufacturer Infiltrator Capacity 1537 Gal. Surface Water 100'+ 100'+ NA NA Material Number of compartments Lot Line 5'+ 10'+ NA NA NA Plastic 2 Foundation 10'+ 10'+ NA NA LIFT STATION Manufacturer Capacity Gal. Remarks Alarm location Electrical installed by PIPE MATERIAL House to tank ASTM F628 Tank to ASTM D1785 drainfield Installer Red Dog Masonry, Inc. Drainfield ASTM D3034 CO/MT F628 / D3034 inspector PES BENCH MARK (Assumed elevation) 500.0 ft Inspeection vt 04/23/24 11/05/24 Location and description ction 31d 11/06/24 2nd 41" 11/21/24 See Site Plan, Top Of Deck ON-SITE WATER AND WASTEWATER SECTION APPROVAL Engineer's Stamp OF• A�q kk Conditional Approval: pp Date �� .....:c X0 �� . • St2Ven R. 7:)cnnone � Septic Syste /ZO2 -Y . J Approved J' --- Date v Note: this appros doenot include well permit requirements. ��® ®��'� (Rev 05/02/18) PROFILE IM-1530 GAL INFILTRATOR PLASTIC TANK PA N N O N E E N G S V C , L L C ( C . I . 1 0 8 8 ) MUNICIPALITY OF ANCHORAGE Development Services Department Phone: 907-343-7904 On-Site Water & Wastewater Section Fax: 907-343-7997 Well Log Permit Number: #__________ Date of Issue: ________ Parcel Identification Number: __________________ Date Started: _________ Date Completed: _________ Is well located at approved permit location? Yes No Legal Description:_________________________________________________________________________ Property Owner Name & Address: _______________________________________ _______________________________________ _______________________________________ Borehole Data: Depth (ft) Soil Type, Thickness & Water Strata From To Method of Drilling air rotary cable tool Casing type: _________ Wall Thickness: inches Diameter: inches Depth: feet Liner Type: _________ Diameter: inches Depth: feet Casing stickup above ground: feet Static water level (from ground level): feet Pumping level: feet after hours pumping gpm Recovery Rate: gpm Method of Testing: _________ Well Intake Opening Type: Open End Open Hole Screened Start feet Stopped feet Perforations Start feet Stopped feet Grout Type: _________ Volume: _________ Depth: _________ Start feet Stopped feet Well Disinfected Upon Completion? Yes No Method of Disinfection: Comments: Well Driller: _____________________________ Company: _____________________________ Mailing Address: _____________________________ Water Sample Results: Arsenic: _________ ug/L Nitrates: _________ mg/L Total Coliform Bacteria:_________ colonies/100mL Attention: The well driller shall provide a well log to the On-site Water and Wastewater Section within 30 days of completion. www.sullivanwaterwells.com Pump Installation Log Well Drilling Permit Number: OSP 241049 Date of Issue 4/9/24 Parcel Identification Number: 02102153000 Legal Description Property Owner Name & Address CANYON VIEW ESTATES BLK 2 LT 7 Hultquist Homes 13852 Canyon Rd. Anchorage, AK 99516 Pump Installation Date: 10/18/24 Pump Intake Depth Below Top of Well Casing: 272 feet Pump manufacturer’s Name: Grundfos Pump Model: 10SQE15-330 Pump Size: 1.5 hp Pitless Adapter Burial Depth: 12 feet Pitless Adapter Installer: Pitless Manufacturer: Disinfected Upon Completion? yes no Method of Disinfection: Chlorine 50 PPM Comments: Pump Installers Name: Sullivan Water Wells Attention: The pump installer shall provide a pump installation log to the DSD within 30 days of pump installation. Merrill Unknown Lot 7, Block 2, Canyon View Estates Subdivision Asbuilt Land Surveying Land Development Consultants Subdivision Specialists Construction Surveying AEC# 173042 S4 Group 124 E 7th Avenue Anchorage, Alaska 99501 (907) 306-8104 mail@S4AK.com 11/27/2024 MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Water & Wastewater System Permit Permit Number: OSP241049 Work Type: WellSeptic Initial Tax Code Number: 02102153000 Site Legal Address: CANYON VIEW ESTATES BLK 2 LT 7 G:3042 Site Mailing Address: Owner: HULTQUIST HOMES INC Design Engineer: PANNONE ENGINEERING SERVICES This permit is for the construction of: Effective Date: Expiration Date: Lot Size in Sq Ft: Total Bedrooms: 4/9/2024 4/9/2025 77688 Q Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy 2 Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Received By: A S Ei5 Issued By: Date: Date: J,� 2 4 MUNICIPALITY OF ANCHORAGE Community Development Department Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On -Site Water & Wastewater Program ON -SITE SEWER/WELL PERMIT APPLICATION a Parcel I.D. 021-021-53 Property owner(s) Hultquist Homes, Inc. Day phone Mailing address Site address NHN Canyon Road Legal description (Sub'd., Block & Lot) Canyon View Estates Block 2 Lot 7 Legal description (Township, Range & Section) Lot Size 77,688 Sq. Ft. Number of Bedrooms 4 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (N all that apply) Absorption Field Initial ❑x Single Family (SF) ❑x Septic Tank Upgrade El(w/wo ADU) Holding Tank ❑ Renewal ElDuplex (D) El Privy ❑ Multiple Dwellings ❑ (SF and/or D) Private Well x❑ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: I Date of Payment: c Z0 Z Receipt Number: Permit No. Waiver Fees: Date of Payment: Receipt Number: Waiver No. Permit App_'- :- .' . c 1::1- 3- Pannone Engineering Services LLc Steven R. Pannone, Principal Registered Professional Engineer E-mail: steveCDpaneneak.com Municipality of Anchorage Development Services Department On -Site Water & Wastewater Program 4700 Elmore Road Anchorage, Alaska Subject: Canyon View Estates Block 2 Lot 7 Septic System Initial Permit Request This is a design narrative for a permit to install an initial well and septic system on the subject property. The proposed system will serve a proposed four -bedroom (4) house. This lot and surrounding lots are served by private wells. Currently there are no wells within 100 feet of the proposed system. 1. Soils: A test hole was performed on this lot by Pannone Engineering Services, LLC on (4/24/2024). Ground water and bedrock were not observed during excavation of this test hole. Groundwater was observed in the test hole monitor tube after 7-days at a level of (10.5') below grade on (05/14/2024). Based on the results of the percolation test, overall soils appearance, and selection of the proposed drain field; an application rate of 1.2 gpd/SF was used for the design of a conventional wastewater treatment system in the area of the test hole. The percolation rate was faster than 1 mpi—see attached sieve results. 2. Soil Absorption System Design. a. See Sheet 1 of the design package. 3. Surface Water: There is no surface water within 100 feet of the proposed septic tank and drain field. 4. Topography: See attached site plan for area topography. The drain field will meet the provisions of the steep slope section of the code with slopes over 25% but less than 46% located downhill of the proposed field. 5. Drawing Markings: The Drawings are marked "For MOA Review Only". When written notification that the review is complete and no further comments are received from MoA On -Site Department, the note will be removed and "For Construction" drawings will be issued. The proposed installation will not affect the future development of this or the surrounding lots. If you have any questions or concerns, please contact me at (907) 745-8200. Sincerely, Is T_�_>_P Steven R. Pannone, P.E., F. ASCE Owner/Civil Engineer 15 May 2024 Mailing: P.O.Box 1807, Palmer, AK 99645 Telephone: (907) 745-8200 FAX: (907) 745-8201 DESIGN PARAMETERS PRIMARY/RESERVE SEPTIC SYSTEMsEPTic NO. BEDROOM: 4(600 gpd) (E� TANK SIZE: 1250g (MIN) O \ 0 PERC RATE: <1 MPI / ------ _Al \ � SOIL RATING: 1.2 GPD/SF 0 AREA RQD: 500 SF SYS. TYPE: WIDE TRENCH 2.0' ED RF: 0.70 i / -A \�\ MIN LENGTH: 70 LF USE: ,!�, / Lot 7 70LFx5.0'Wx2.0'E.Dx6.0'TD TOTAL AREA: 500 SF / /��� o \� z�\ \ TH-7 CP0 �\ \ \\ y X / rF (2023) \ V Block 2 A. WELL P \� O / / =�' J B HOUSE \ 1 E1Jp� \ TH- 7A �P> age \ Q���/ (2024) O\N 10.4 �L��` OSIER s INSTALL MIN 1250gal SEPTIC TANK (P) 8'0 INSTALL FC BEFORE AND DCO AFTER. IF BOTTOM OF TANK WILL BE AT A GREATER ��N OF 1 \ \ s� DEPTH THAN 1 1.5' BELOW ORIGINAL GRADE / PP k INSTALL MoA APPROVE STEEL TANK. \�� \ IF PLASTIC TANK / \ _j ` - — IS USED INSTALL MONITOR TUBE. \ PRIMARY/RESERVE DRAIN FIELD (P) L o jM M I 70LF x 5.0'W x 2.0'ED x 6.0'TD \ \ \ \ iINSTALL CLEAN OUT AND MONITOR TUBE AT EACH D \ / oX � o TH-2023-8 \ \ THE CONTRACTOR, AND OR THE PROPERTY OWNER RESPONSIBLE FOR THE INSTALLATION OF THE \ o \ \PROPOSED WASTEWATER TREATMENT SYSTEM SHALL NOTIFY PES A MINIMUM OF 24-HOURS IN ADVANCE MONDAY THROUGH FRIDAY OF THE REQUIRED PRE -CONSTRUCTION INSPECTION. AT THIS TIME A REPRESENTATIVE OF PES AND THE CONTRACTOR OR PROPERTY OWNER WILL 1. DISCUSS CONSTRUCTION PROCEDURES AND DESIGN REQUIREMENTS. I 1 2. VERIFY SITE CONDITIONS CONFORM TO THE DESIGN PLANS AND PERMIT. 1 ` 3. VERIFY THE PROJECT LAYOUT CONFORMS TO THE DESIGN PLANS AND PERMIT. \ \ (Ref: AMC 15.65) \ PLEASE REFER TO THE NOTES AND SPECIAL PROVISIONS PAGE FOR MORE INSPECTION INFORMATION. PES \ SHALL NOT BE HELD LIABLE FOR INSTALLATIONS NOT MEETING THE REQUIREMENTS OF 18 AAC 72 AND/OR AMC 15.65 AND THE SPECIAL PROVISIONS OF THIS PERMIT AS APPLICABLE IF THE CONTRACTOR / AND OR PROPERTY OWNER FAIL TO GIVE PES PROPER NOTICE. PES WILL ATTEMPT TO DOCUMENT THE \\ SYSTEM AND OBTAIN ANY NECESSARY WAIVERS AT THE CONTRACTOR AND OR PROPERTY OWNERS EXPENSE. 1 J PES MAKES NO GUARANTEES THAT ANY NEEDED SEPARATION DISTANCES WAIVERS WILL BE APPROVED BY \AEDC OR THE MUNICIPALITY OF ANCHORAGE ONSITE DEPARTMENT STAFF. 1 NOTES: PANNONE ENG SVC, LLC z Date CHANGE ORDER P.O. BOX 100217 ANCHORAGE, AK 99510 .(� 5/15/2024 PHONE (907) 272-8218 FAX (907) 272-8211P••••• Scale 1"=50' •• ••••••• P.I.D. NO DRAWN BY: DRM CANYON VIEW ESTATES, BLOCK 2, LOT 7 021-021-53 HULTQUIST HOMES INC. •• }evan anriome PERMIT NO. CE NSN CANYON ROAD 8t49 OSP241049 PLAN ANCHORAGE, AK j. Sheet 1 OF 3 SPECIAL PROVISIONS TO SPECIFICATIONS . GENERAL NOTES: 1.1. ANY MODIFICATIONS TO THE ATTACHED PLANS NEED TO BE APPROVED BY PES AND THE OWNER OF THE PROPERTY. 1.2. PES SHALL BE NOTIFIED A MINIMUM OF 48 HOURS IN ADVANCE BEFORE CONSTRUCTION OF THE PROPOSED WASTEWATER TREATMENT SYSTEM. 1.3. PES SHALL BE NOTIFIED A MINIMUM OF 24 HOURS IN ADVANCE TO PERFORM A MINIMUM OF FOLLOWING INSPECTIONS: 1.3.1. A PRE CONSTRUCTION MEETING IS REQUIRED BY STATE AND MUNICIPAL REGULATIONS BEFORE A ONSITE WASTEWATER TREATMENT SYSTEM MAY BE INSTALLED. 1.3.2. TOP OF SEPTIC AND OR HOLDING TANK (TANK IS SET IN PLACE LEVEL WITH ALL PIPING ATTACHED (CLEANOUTS, MANHOLES, INLET AND OUTLET PIPING). 1.3.3. BOTTOM OF EXCAVATION OF THE DRAIN FIELD/S. 1.3.4. AFTER PLACEMENT OF FILTER SAND (IF NEEDED). 1.3.5. AFTER INSTALLATION OF THE DRAIN ROCK WITH ALL ASSOCIATED PIPING IN PLACE INCLUDING DISTRIBUTION LINES CLEANOUTS AND MONITOR TUBES PRIOR TO INSTALLATION OF FILTER FABRIC AND INSULATION (IF NEEDED). 1.3.6. FINAL GRADE INSPECTION. ENTIRE SYSTEM IS INSTALLED AND BACKFILLEO. 1.4. THE ENGINEER (PES) HAS NO CONTRACTUAL RELATIONSHIP WITH THE CONTRACTOR (THE INSTALLER OF THE SYSTEM) AND, THEREFORE, HAS NO AUTHORITY, CONTROL OR RESPONSIBILITY FOR THE CONTRACTOR'S EMPLOYEES, THE QUALITY OF WORK, THEIR COMPLIANCE WITH THE DESIGN DRAWINGS/SPECIFICATIONS OR THEIR MEANS/METHODS OF CONSTRUCTION. AT APPROPRIATE INTERVALS, THE ENGINEER WILL VISIT THE WORKSITE TO OBSERVE THE QUALITY OF THE CONSTRUCTION AND TO DETERMINE IN GENERAL IF THE CONSTRUCTION IS PROCEEDING IN ACCORDANCE WITH THE DESIGN DRAWINGS/SPECIFICATIONS.THE ENGINEER WILL NOTIFY THE OWNER IF DEFICIENCIES ARE OBSERVED; HOWEVER, THE FAILURE OF THE ENGINEER TO OBSERVE A DEFICIENCY WILL NOT RELIEVE THE CONTRACTOR OF THE RESPONSIBILITY FOR CORRECTING ANY SUCH DEFICIENCY. THE ENGINEER WILL PREPARE RECORD DRAWINGS AND SUBMIT THEM TO THE REGULATORY AGENCY HAVING JURISDICTION OVER THE WASTEWATER TREATMENT SYSTEM (ADEC OR MOA). FINAL APPROVAL OF THE WORK AND CORRECTION OF ANY DEFICIENCIES IS BETWEEN THE OWNER, THE CONTRACTOR, AND THE REGULATORY AGENCY HAVING JURISDICTION OVER THE WASTEWATER TREATMENT SYSTEM (ADEC OR MOA). 2. SCOPE AND SPECIFICATIONS: 2.1. ALL CONSTRUCTION SHALL BE INSTALLED AS SPECIFIED IN THE MOST CURRENT EDITION OF THE MOA COMPONENT PARTS AND MATERIALS USED IN CONSTRUCTION OF ON -SITE WASTEWATER DISPOSAL SYSTEMS AND AND IN ACCORDANCE WITH AMC 15.65 AND 15.55. 2.2. CONTRACTED WORK WILL BE IN COMPLIANCE WITH MUNICIPALITY OF ANCHORAGE STANDARD SPECIFICATIONS (MASS) DIVISION 10 & DIVISION 20 AS APPROPRIATE. 2.3. SCOPE OF WORK: INSTALL SYSTEM PER DESIGN 2.4. GROUNDWATER WAS NOT ENCOUNTERED TO A DEPTH OF 10.5 FEET BELOW EXISTING GRADE AS EVIDENCED BY THE SOIL TEST HOLE. IF AN APPARENT WATER TABLE IS OBSERVED IN ANY OF THE EXCAVATIONS LESS THAN 10.5 FEET BELOW EXISTING GRADE NOTIFY THE ENGINEER IMMEDIATELY. 2.5. STRUCTURES DEPICTED ON THE SITE PLAN ARE BASED UPON ONE OF THE FOLLOWING: CONCEPTUAL PLOT PLAN DEVELOPED BY OWNER; A PLOT PLAN DEVELOPED BY RLS; OR A SURVEY AS -BUILT. 3. CONSTRUCTION SPECIFICATIONS: 3.1. ALL EXCAVATION DEPTHS ARE ADVISORY. THEY ARE TO BE VERIFIED AND MAY BE MODIFIED BY THE ENGINEER IF ACTUAL FIELD CONDITIONS VARY FROM THOSE USED TO PREPARE THE DESIGN 3.2. EXCAVATE THE DRAIN FIELD. BOTTOM OF EXCAVATION SHALL BE LEVEL AND SCARIFIED. RECORD ELEVATIONS AT BEGINNING, MIDDLE AND END OF TRENCH BOTTOM. CONSTRUCTION EQUIPMENT SHALL NOT OPERATE ON THE FLOOR OF THE EXCAVATION. ANY MATERIAL COMPACTED BY THE OPERATION OF THE CONSTRUCTION EQUIPMENT SHALL BE REMOVED AND REPLACED WITH UNCOMPACTED MATERIAL. 3.3. PLACE THE SEWER ROCK TO THE SPECIFIED DEPTHS. DO NOT CONTAMINATE SEWER ROCK WITH NATIVE MATERIAL OR SPOILS FROM EXCAVATION. LEVEL ROCK SURFACE TO ±1" PRIOR TO INSTALLING THE PERFORATED PIPE. 3.4. ALL PIPE SHALL BE PVC CONFORMING TO ASTM D3034 OR ENGINEER APPROVED EQUAL. MINIMUM SOIL COVER SHALL BE 3 FEET OVER THE PIPE AND 4 FEET OVER THE SEPTIC TANK. ONE INCH OF INSULATION MAY BE SUBSTITUTED FOR 1 FOOT OF SOIL COVER. 3.5. ALL INSULATION SHALL BE 2" THICK DOW HI-40 INSULBOARD OR ENGINEER APPROVED EQUAL. CENTER INSULBOARD WIDTH OVER SEPTIC TANK OR LINES. 3.6. GEOTEXTILE SHALL BE MIRAFI 140S OR ENGINEER APPROVED EQUAL. LAP ALL JOINTS 2 FEET MINIMUM. 3.7. COVER THE DISTRIBUTION PIPE WITH A MINIMUM OF 2" OF SEWER ROCK AND COVER WITH GEOTEXTILE BEFORE PLACING INSULATION AND BACKFILL. 3.8. MATERIAL USED AS FILL SHALL BE CLEAN AND FREE OF ORGANICS, TRASH AND CONSTRUCTION DEBRIS. 3.9. SLOPE ALL FILL MATERIAL TO DRAIN AT 27 MINIMUM SLOPE AND 3:1 MAXIMUM SLOPE AND IN SUCH A MANNER THAT PONDING AT OR NEAR THE DRAIN FIELD DOES NOT OCCUR. THE FILL SHALL BE LEFT AT 6" HIGHER THAN SHOWN TO ALLOW FOR SETTLEMENT. SEED SURFACE AFTER COMPLETING INSTALLATION AS PER MOA CODE. 3.10. RECORD THE FINISH GROUND ELEVATION OVER THE BEGINNING, MIDDLE AND END OF SYSTEM. 3.11. MAINTAIN 5' SEPARATION BETWEEN PERCOLATION HOLE AND THE DRAIN FIELD TRENCH. 3.12. EXPOSE, PUMP AND FILL LOG DISPOSAL CRIB OR CONCRETE TANK WITH SOIL TO ABANDON IAW WITH MOA CODE IF NEEDED. 4. CONTRACTOR RESPONSIBILITIES: 4.1. THE CONTRACTOR SHALL FAMILIARIZE THEMSELVES WITH THE SITE CONDITIONS AND LOCATIONS OF ALL LOT LINES. EASEMENTS, WELLS (E & P), SEPTIC SYSTEMS (E & P) AND SHALL MEET MINIMUM SEPARATION DISTANCES OR AS NOTED. 4.2. THE CONTRACTOR (BOTH WELL AND SEPTIC SYSTEM CONTRACTORS) SHALL HAVE ANY WELL LOCATION AND SEPTIC LOCATION STAKED AND ANY LOT LINE AND WELL RADIUS SHOWN ON THE PLAN WITHIN 30 FEET OF THE PROPOSED SYSTEM STAKED BY A REGISTERED LAND SURVEYOR BEFORE STARTING THE WORK. 4.3. THE CONTRACTOR IS RESPONSIBLE FOR ALL R.O.W. AND OTHER REQUIRED PERMITS, OTHER THAN THE ATTACHED. 4.4. THE CONTRACTOR SHALL CALL FOR LOCATING OF ALL BURIED UTILITIES. 4.5. THE CONTRACTOR SHALL PROVIDE 24 HOUR NOTICE TO THE ENGINEER PRIOR TO START OF WORK. ALL SURVEYING AND LOCATES SHALL BE IN PLACE PRIOR TO NOTIFYING THE ENGINEER. 4.6. THE CONTRACTOR SHALL NOTIFY THE ENGINEER OF ANY DISCREPANCY BETWEEN THE APPROVED DRAWINGS AND SITE CONDITIONS/LIMITATIONS POTENTIALLY CAUSING THE NEED TO MODIFY THE DESIGN. 4.7. AT THE COMPLETION OF THE WORK, THE CONTRACTOR SHALL SUBMIT RED -LINE AS -BUILT DRAWINGS TO THE ENGINEER. THE RED -LINES SHALL INCLUDE PIPE LENGTHS, ORIGINAL GROUND ELEVATIONS, PIPE ELEVATIONS, AND TANK ELEVATIONS. 4.8. THE CONTRACTOR SHALL PROVIDE PHOTOGRAPHS OF THE SYSTEM INSTALLATION TO INCLUDE BOTTOM OF EXCAVATION, TOP OF PIPE WITH CLEAN -OUTS AND MONITOR TUBES INSTALLED, INSTALLED TANK AND FINAL GRADING. 5. THE CONTRACTOR SHALL SIGN THE FOLLOWING: I CERTIFY THAT ALL WORK WILL BE PERFORMED IN ACCORDANCE WITH THE APPROVED PERMIT, AND ANY AND ALL CHANGE ORDERS. AND THAT THE AS -BUILT REDLINES ARE TRUE AND ACCURATE REPRESENTATION OF THE PROJECT AS CONSTRUCTED. THE PARTIES HEREBY AGREE TO THE TERMS AND CONDITIONS SET FORTH IN ATTACHED DOCUMENTS. CLIENT: CONTRACTOR:: NAME: NAME: SIGNATURE: SIGNATURE: DATE: DATE: NOTES: PAMONE ENG SVC LLC Date CHANGE ORDER P.O. BOX 100217 ANCHORAGE, AK 99510 5/15/2024 PHONE (907) 272-8218 FAX (907) 272-8211;•• ••• Scale *� �m. • �* NTS •• ••••••• P.I.D. NO CANYON VIEW ESTATES, BLOCK 2, LOT 7 021-021-53 HULTQUIST HOMES INC. •• °Y°� °"^Oot°CE PERMIT N0. NSN CANYON ROAD 8149 OSP241049 DESIGN DETAILS ANCHORAGE, AK Sheet 2OF3 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 TH 7A (2024) OR I TOPSOIL BOH POORLY GRADED SAND WITH SOME FINES AND GRAVE 5/14/24 DATE PERFORMED: 2024-04-24 SOILS LOG - PERCOLATION TEST SLOPE .TEST HOLE WAS GROUND WATER ENCOUNTERED? N IF YES, AT WHAT DEPTH? -NA- DEPTH TO WATER AFTER MONITORING? -10.5' DATE: 14MAY24 COMMENTS: Test hole excavated by RED DOG MASONRY PERFORMED BY: PES. I CERTIFY THATTHIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDLINES IN EFFECT ON THE DATE OF THIS TEST. SITE PLAN co' SLOPE TH 1 SOIL TEST RESULTS/ANALYSIS • PERCOLATION RATE <1.0 mpRmin/inch) (Hydrologic Soils Group: HSG A) • PERC HOLE DIAMETER 6" • TEST RUN BETWEEN 3 FT AND 4 FT. WATER RATE READING DATE NET TIME LEVEL NET DROP (MPI) READING 1 24APRIL24 2 WATER ABSORBED TO ACCURATELY TOO QUICKLY READ 3 4 5 6 NOTES: PANNONE ENG SVC LLC �� Date CHANGE ORDER P.O. BOX 102954 ANCHORAGE, AK 99510 Q'���- ""�'/1 /2024e PHONE (907) 272-8218 FAX (907) 272-8211 •�'! le .... .. . ....... P.I.D. NO CANYON VIEW ESTATES, BLOCK 2, LOT 7 021-021-53 HULTQUIST HOMES INC. "even anne PERMIT NO. NSN CANYON ROAD CE 8149, OSP241049 SOILS LOG ANCHORAGE, AK '•••• Sheet 3 OF 3 040.002 Crowther Associates Date: May 13, 2024 C Client: Pannone Engineering Services, Name Project: Canyon View Block 2 Lot 7 Particle Size Distribution Table (percent passing subject sieve size) Sample Source Test pit a Moisture Content 7.4% Sieve Size Percent Finer Percent Finer Percent Finer Percent Finer 3 inch 100 1-1/2 inch 100 3/4 inch 83 #4 50 #10 29 #40 8 #100 3 #200 2 0.02 min XX Classification Gravelly Sand (SP) Invoice 215 1632 Bellevue Circle /Anchorage, Alaska 99515 Telephone (907) 349-2198 / E mail: 907crowther@gmail. con? PA N N O N E E N G S V C , L L C ( C . I . 1 0 8 8 ) COMMENTS: Test hole excavated by BROWNSON BROS, LLC. PERFORMED BY: PANNONE ENGINEERING SERVICES, LLC. I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDLINES IN EFFECT ON THE DATE OF THIS TEST. ·<1 (min/inch) ·6" ·2 FT AND 3FT SOILS LOG & PERCOLATION TEST Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP241049, Curtis Townsend, 04/09/24 040.002 Crowther Associates 1632 Bellevue Circle / Anchorage, Alaska 99515 Telephone (907) 349-2198 / E mail: crowther@alaska.net Client: Pannone Engineering Services Project: Canyon View SD Block 2 Date: May 18, 2023 Particle Size Distribution Table (percent passing subject sieve size) Sample Source 7 8 9 10 Moisture Content 7.0%6.9%6.8%12.1% Sieve Size Percent Finer Percent Finer Percent Finer Percent Finer 3 inch 100 100 100 100 1-1/2 inch 100 100 100 100 ¾ inch 96 91 92 100 #4 58 56 57 93 #10 38 66 37 82 #40 14 19 15 24 #100 7 12 10 10 #200 6 11 9 7 0.02 mm xx xx xx xx Classification Gravelly Sand with Silt (SP-SM) Gravelly Sand with Silt (SP-SM) Gravelly Sand with Silt (SP-SM) Sand with Silt (SP-SM) Invoice 192 MUNICIPALITY OF ANCHORAGE Development Services Department Phone: (907)343-7904 On -Site Water & Wastewater Section Fax: (907)343-7997 Parcel ID 021 -021-53 Certificate of On -Site Systems Approval OSC241500 Expiration Date: Legal description CANYON VIEW ESTATES BLK 2 LT 7 Site address 13852 CANYON RD Current property owner(s) HULTQUIST HOMES INC X The On-site system(s) is/are approved for 4 bedrooms Conditional approval for bedrooms, with the following stipulations: Comments or conditions: By: Original Certificate Date: 12/13/2024 This Certificate of On -Sit e//Sy terns Approval (COSA) is intended to demonstrate the subject system(s) is/are in su�siantial compliance with municipal code. The Municipality of Anchorage, Development Service Department (DSD) issues COSAs based upon representations provided by an independent professional engineer. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's submittal. ATTACHMENTS: COSA Checklist X Well Flow Advisory Absorption Field Advisory Nitrate Advisory Tank Age Advisory Arsenic Advisory Other MUNICIPALITY OF ANCHORAGE Development Services Department; Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Certificate of On -Site Systems Approval Application 1. GENERAL INFORMATION Parcel 1. D. 021-021-53 Complete legal description Canyon View Estates Block 2 Lot 7 Location (site address) 13852 Canyon Road Current property owner(s) Hultquist Homes, Inc. Day phone 2. ON-SITE SYSTEMS SIZED FOR 4 BEDROOMS 3. TYPE OF WATER SUPPLY: X Private Well [-I Private Well serving 2 dwelling units F-1 Private Well serving 3+ dwelling units 1771 Community Well or Public F71 Water Storage 4. TYPE OF WASTEWATER DISPOSAL: OR Private Septic E] Private Septic serving 2 dwelling units F71 Holding Tank F] Community Septic or Public Sewer 5. SEPTIC TANK: 1-71 Steel FN Plastic 0 Concrete F] Fiberglass Age <1 - See advisory if steel older than 20 years 6. ABSORPTION FIELD: ❑ AWWTS E] Bed R Deep Trench MR Wide Trench R Seepage Pit Waiver request for: Expedited review requested: El Distance: By applying for this entitlement, this property is subject to inspection by municipal On-site staff to verify the accuracy of the information provided. COSA Fee $ 7 Waiver Fee $ Date of Payment A') COSA # S Date of Payment Waiver # COSA Application—June 2022 COSA Checklist_June 2022 COSA Checklist Legal Description: Parcel ID: If more than 1 well and/or septic system on lot, provide separate checklist. Structure served by this system ____ A. WELL DATA Well log is filed with Onsite (or attached) Date drilled Total depth ft Cased to ft Sanitary seal is functioning correctly Wires are properly protected Casing height (above ground) in. Date of flow test for COSA Static water level at beginning of test ft. Well production at time of test gpm Water storage tank volume gallons Well disinfected for coliform test? Yes No Coliform bacteria is Negative Nitrate mg/L Nitrate less than MRL (ND) Arsenic ug/L Arsenic less than MRL (ND) Collected by Date Comments __________________________________________________________________________________ B. TANK DATA Measured operating fluid level in septic tank Date of pumping Required maintenance completed, if AWWTS Comments: C. LIFT STATION Required maintenance completed Age of lift station years Lift station material Comments: D. ABSORPTION FIELD DATA Which system tested (date installed) ALL standpipes present per record drawing Total measured depth from grade ft (max) Measured depth to pipe invert from grade ft (min) N/A – pressurized field. Per record drawings, field is insulated. Monitor tubes go to bottom of effective. If not, state depth into effective Presoaked required if (Required if house vacant or field not used for more than 30 days prior to date of test) Gallons introduced gallons date Any rejuvenation treatment (past 12 months) If yes, enter date Adequacy test date Results Pass Fluid depth prior to test in Water added gal New fluid depth in Elapsed time min Final fluid depth in Absorption rate gpd FIELD STATUS – POST RECOVERY Effective depth (per record drawings) in Effective depth used in Effective depth remaining in Comments/Deficiencies: COSA Checklist_June 2022 E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well on lot) Septic Tank/Lift Station on Lot > 100’ Yes if No ft Neighboring Tank > 100’ Yes if No ft Absorption Field on Lot > 100’ Yes if No ft Neighboring Absorption Fields > 100’ Yes if No ft Community Sewer Main > 75’ Yes if No ft Community Sewer Manhole/Cleanout > 100’ Yes if No ft Private Sewer/Septic Line > 25’ Yes if No ft Holding Tank > 100’ Yes if No ft Animal Containment > 50’ Yes if No ft Manure/Animal Excreta Storage > 100’ Yes if No ft N/A – Served by Community Well (not on lot) or Public Water From Septic/Holding Tank and Absorption Field(s) on Lot to: (Please enter distances if less than required) Building Foundations > 10’ Yes if No ft Tank to Property Line > 5’ Yes if No ft Field to Property Line > 10’ Yes if No ft Water Main > 10’ Yes if No ft Water Service Line > 10’ Yes if No ft Surface Water > 100’ Yes if No ft Wells on Adjacent Lots: Private Wells > 100’ Yes if No ft Community Wells > 200’ Yes if No ft If tank or field is under driveway comment below F.ENGINEER’S COMMENTS G.CERTIFICATION & STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines, indicates that the on-site water supply and/or wastewater disposal system appears to comply with applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation, unless noted otherwise. Name of Firm Phone Engineer’s Printed Name Date