Loading...
HomeMy WebLinkAboutOLSON HEIGHTS BLK 1 LT 3ei lf�,Ison H yk Q�� MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road 4, Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite I Department On -Site Water & Wastewater System Permit Permit Number: OSP241054 Effective Date: 5/23/2024 Work Type: WellSeptic Initial Expiration Date: 5/23/2025 Tax Code Number: 01823104000 Site Legal Address: OLSON HEIGHTS BLK 1 LT 3 G:2936 Site Mailing Address: 4301 E 135th AVE, Anchorage Owner: WILSON KENDALL & SAMANTHA Lot Size in Sq Ft: 49507 Design Engineer: AK BUILT CONSTRUCTION & DESIGN LLC^ Total Bedrooms: 5 This permit is for the construction of: Q Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy Q Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing �Y 1—.55me U fU 1 1` &u 1 I t Issued By: Date: Date: _ _ 30 , Development Services DepartmentPhone: 907-343-7904 On -Site Water & Wastewater Section --~' Fax: 907-343-7997 ON-SITE SEPTIC/WELL PERMIT APPLICATION Parcel I.D. 01823104000 Property owner(s) Wilson Kendall & Samantha Mailing address 4155 Kingston Dr, Anchorage, AK 99504 Site address NHN E 135th Ave, Anchorage, AK 99516 Legal description (Sub'd., Block & Lot) Olson Heights, Blk 1 Lt 3 Day phone 907-223-9980 Legal description (Township, Range & Section) Sec. 27, T12N, R3W, SM Lot Size 49507 Sq. Ft. Number of Bedrooms 5 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (® all that apply) Absorption Field 0 Initial 0 Single Family (SF) El ADU) Septic Tank 0 Upgrade El(w/wo Duplex (D) ❑ Holding Tank ElRenewal ❑ Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well FXr Water Storage ❑ THIS APPLICATION INCLUDES A WAIVER REQUEST FOR: None Distance: N/A I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: 3� y -9 S_ wel Fees: well f 22�;_ Date of Payment: Y/ l ��''� z `/ Date of Payment: gr3of z�( Receipt Number: Receipt Number: 62q Permit No. OS P 0 Sri' Waiver No. GADevelopment Services\Building Safety\On Site Water and Wastewater\Forms\Client Forms\Permit Application.doc PO Box 771203, Eagle River, AK 99577 – Phone: (907) 854-9115 Page 1 of 2 AK Built Construction & Design, LLC General Contracting - Engineering - Project Administration May 14, 2024 Municipality of Anchorage Development Services Department On-Site Water and Wastewater Section PO Box 196650 Anchorage, AK 99519 RE: Olson Heights, Block 1, Lot 3 – Septic System Initial Permit Request A permit is requested to install a conventional septic system for the subject property. The designed system will serve a proposed 5-bedroom, single-family home. The subject property is vacant with no existing structure or existing on-site septic system. An initial system is designed for the subject property and a replacement field of equal capacity is shown with the designed system. Wells The subject property does not have an existing water well. Neighboring parcels are served by private water wells. In the future, the subject property will be served by a private water well. Separation distances stipulated in Anchorage Municipal Code (AMC) 15.65 shall be maintained for future well-sitting. There are no wells within 100’ of the designed system septic system. The future well area shown on the plans maintains a minimum of 100’ from on-lot septic systems and neighboring septic systems. Soils AK Built Construction & Design, LLC (AK Built) performed test holes, percolation tests, and groundwater monitoring on April 5th and May 13th, 2024. Groundwater was not encountered in TH-01 but was observed at least seven (7) days later at twelve (12) feet BGS. Groundwater was encountered at seven (7) feet below ground surface (BGS) and observed at least seven (7) days later at four and a half (4 ½) feet BGS in TH-02. After an initial review by the On-Site Water and Wastewater Section, it was determined an additional test hole would be required to have a percolation test result within 30-feet of the entire soil absorption system. TH-03 was excavated on April 29th, 2024. A groundwater seep was noted at the bottom of TH-03. An application rate of 0.6 gallons/day/square feet shall be used for a conventional wastewater system. Confirm groundwater conditions at time of construction. Wastewater disposal systems The designed wastewater disposal system is a wide trench (5-wide system) with 36” of sewer rock. The designed system has the following characteristics. # Bedrooms: 5 Daily Design Flow: 750 gallons/day Tank Size: 1,500 gallons Percolation Rate: 30 minutes/inch Soil Rating: 0.6 gallons/day/square feet Field Area Required: 1,250 square feet System Type: Wide Trench (5 Wide) with 36” sewer rock Minimum Length: 145 feet Designed Trench Length: (2) 75 feet Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP241054, Deb Wockenfuss, 05/23/24 PO Box 771203, Eagle River, AK 99577 – Phone: (907) 854-9115 Page 2 of 2 AK Built Construction & Design, LLC General Contracting - Engineering - Project Administration Designed Field Area: 1,293 square feet Maximum Excavation Depth (from existing ground) Allowed: 8 feet Replacement disposal site The subject property has no existing on-site septic system. As a part of this system design, a reserve field of equal capacity is identified to show availability of a replacement system. TH-02 represents the soil characteristics for the reserve field. The percolation rate for TH-02 is faster than one (1) minute/inch and groundwater was encountered. The replacement system is a bed with 6” of sewer rock and a 2’ sand liner. The reserve system has the following characteristics. Confirm groundwater conditions at time of construction. Coordinate with any future developments not known at this time. # Bedrooms: 5 Daily Design Flow: 750 gallons/day Tank Size: 1,500 gallons Percolation Rate: 0-1 minutes/inch Soil Rating: 0.7 gallons/day/square feet Field Area Required: 1,071.4 square feet System Type: Bed with 6” sewer rock Bed Width: 20 feet Minimum Length: 53.57 feet Designed Length: 54 feet Designed Field Area: 1,080 square feet Maximum Excavation Depth (from existing ground) Allowed: 0.5 feet Drainage There is no surface water located within 100’ of the designed system. There is a storm drainage ditch along W 135th Ave. The designed system will not have an impact on the roadway ditch. Topography The designed system is in the northwest corner of the subject property. The surrounding property generally slopes from east to west and the area immediately surrounding the drain field is flat. There are no steep slopes in the vicinity of the designed system. The designed system does not have probable adverse impacts to adjacent properties. If you have any questions, please contact me. Sincerely, Robert Colles, PE AK Built Construction & Design, LLC Project Manager/Managing Member 907-854-9115 rlcolles@akbuilt.net W TH TH TH OLSON HEIGHTS BLOCK 1, LOT 2 OLSON HEIGHTS BLOCK 1, LOT 4 OLSON HEIGHTS BLOCK 1, LOT 3 OL S O N H E I G H T S BL O C K 2 , L O T 3 OL S O N H E I G H T S BL O C K 2 , L O T 4 OL S O N H E I G H T S BL O C K 2 , L O T 2 McCABE WEST LOT 4 McCABE WEST LOT 5 PROPOSED 5-BEDROOM HOUSE R100' R 100' R100 ' R1 0 0' R100' EXISTING SEPTIC FIELD EXISTING SEPTIC FIELD EXISTING SEPTIC FIELD EXISTING SEPTIC FIELD 38 5 3 90 395 400 3 90 388 389 387 3 87 38 6 38 8 387 3 8 6 RESERVE FIELD PROPOSED DRIVEWAY TH-01 TH-02 10'10 ' 5' 6' 5' 75' 10 ' 1,500-GAL SEPTIC TANK BCO DCO CO MT MT COE 1 3 5 T H A V E PERMISSIBLE WELL SITING, WELL SHALL NOT CONFLICT WITH FOOTPRINT OF FUTURE DRIVEWAY 100 ' 1 0 0 ' T O T A N K 1 0 2 . 0 2 ' 10'x190' CEA & ATU UTILITY EASEMENT, CENTERED ON PROPERTY LINE 10' CEA & ATU UTILITY EASEMENT FLOW SPLITTER TH-03 16 ' 20 ' 54' FILL LIMITS, TYP FI L E P A T H : C : \ U s e r s \ c o l l e \ O n e D r i v e - A K B u i l t C o n s t r u c t i o n & D e s i g n \ A K B u i l t \ P r o j e c t s \ 0 0 3 1 . 0 1 W i l s o n O l s o n H e i g h t s B l k 3 L o t 1 \ A C A D \ 0 0 3 1 . 0 1 - S i t e P l a n . d w g PL O T D A T E : 5 / 1 4 / 2 0 2 4 AK BUILT CONSTRUCTION & DESIGN, LLC PO BOX 771203 EAGLE RIVER, AK 99577 (907)854-9115 CERTIFICATE OF AUTHORIZATION #204451 OL S O N H E I G H T S , B L O C K 1 , L O T 3 SE P T I C S Y S T E M D E S I G N AN C H O R A G E , A L A S K A AK B U I L T P R O J E C T N O : 0 0 3 1 . 0 1 SA M A N T H A & K E N D A L L W I L S O N 3OF SHEET: 5/14/2024 DATE: SHEET TITLE: Robert Colles, PE No. CE-163739REGISTEREDPROFESSIONALE N GINEER 5/14/2024 SEPTIC SYSTEM (E) WELL (E) BUILDING (E) BUILDING (P) SEPTIC SYSTEM (P) CULVERT (E) WELL RADIUS (E) PROPERTY LINE EASEMENT W LEGEND: 00 20' 40' N SITE PLAN 1 ABBREVIATIONS: BCO BUILDING CLEAN OUT CO CLEAN OUT DCO DOUBLE CLEAN OUT (E) EXISTING GAL GALLON MT MONITORING TUBE (P) PROPOSED TH TEST HOLE NOTE: 1. THE EXISTING LOT IS VACANT AND UNDEVELOPED. A RESERVE FIELD IS SHOWN TO IDENTIFY SUFFICIENT AVAILABLE AREA FOR REPLACEMENT OF THE DESIGNED SYSTEM WITH AN EQUIVALENT CAPACITY FIELD. 2. RESERVE FIELD SHALL BE A MOUND STYLE BED SYSTEM REQUIRING A PUMP CHAMBER AND PRESSURE DISTRIBUTION TO MAINTAIN GROUND WATER SEPARATION REQUIREMENTS. 3. McCABE WEST LOT 4 IS SERVED BY A PRIVATE WELL LOCATED 100'+ AWAY FROM DESIGNED SYSTEM. 4. OLSON HEIGHTS BLOCK 1, LOT2 SEPTIC SYSTEM IS 100'+ FROM DEPICTED PERMISSIBLE WELL SITING AREA. Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP241054, Deb Wockenfuss, 05/23/24 FI L E P A T H : C : \ U s e r s \ c o l l e \ O n e D r i v e - A K B u i l t C o n s t r u c t i o n & D e s i g n \ A K B u i l t \ P r o j e c t s \ 0 0 3 1 . 0 1 W i l s o n O l s o n H e i g h t s B l k 3 L o t 1 \ A C A D \ 0 0 3 1 . 0 1 - N o t e s . d w g PL O T D A T E : 5 / 1 4 / 2 0 2 4 AK BUILT CONSTRUCTION & DESIGN, LLC PO BOX 771203 EAGLE RIVER, AK 99577 (907)854-9115 CERTIFICATE OF AUTHORIZATION #204451 OL S O N H E I G H T S , B L O C K 1 , L O T 3 SE P T I C S Y S T E M D E S I G N AN C H O R A G E , A L A S K A AK B U I L T P R O J E C T N O : 0 0 3 1 . 0 1 SA M A N T H A & K E N D A L L W I L S O N 3OF SHEET: 5/14/2024 DATE: SHEET TITLE: Robert Colles, PE No. CE-163739REGISTEREDPROFESSIONALE N GINEER 5/14/2024 DESIGN NOTES 2 SYSTEM DESIGN: 1. DESIGNED SYSTEM IS FOR OLSON HEIGHTS, BLOCK 1, LOT 3. MUNICIPALITY OF ANCHORAGE (MOA) PARCEL ID 1823104000. 2. DESIGNED SYSTEM WILL SERVE A PROPOSED 5-BEDROOM, SINGLE FAMILY HOME. 3. THREE TEST HOLES WERE EXCAVATED TO COLLECT SOIL, PERCOLATION, AND GROUND WATER DATA FOR THE DESIGNED SYSTEM AND RESERVE FIELD. 4. SEPTIC TANK CAPACITY IS A MINIMUM OF 1,000-GALLONS PLUS 250-GALLONS FOR EACH BEDROOM OVER THREE. 4.1. 1,000 GAL+ 250 GAL x (5 BDRM - 3 BDRM) = 1,500 GAL. 4.2. SEPTIC TANK SHALL BE A 1,500-GALLON CAPACITY TANK. 5. DISPOSAL FIELDS SHALL BE DESIGNED TO ACCEPT 150-GALLONS OF WASTEWATER PER BEDROOM PER DAY. 5.1. DESIGN FLOW = 150 GPD/BDRM x 5 BDRM = 750 GPD. 6. THE MINIMUM EFFECTIVE ABSORPTION AREA OF A DISPOSAL FIELD SHALL BE CALCULATED USING THE WASTEWATER APPLICATION RATE CORRESPONDING TO THE PERCOLATION RATE IN ANCHORAGE MUNICIPAL CODE (AMC) 15.65 TABLE 2. 6.1. PERCOLATION RATE = 30 MIN/IN. 6.2. APPLICATION RATE = 0.6 GPD/SF (PER AMC 15.65 TABLE 2). 6.3. MINIMUM EFFECTIVE ABSORPTION AREA = 750 GPD / 0.6 GPD/SF = 1,250 SF 7. DISPOSAL FIELD SHALL BE A WIDE TRENCH. 7.1. TRENCH WIDTH (W) = 5 FT 7.2. EFFECTIVE DEPTH (D) = 3 FT 7.3. SIZE FACTOR = (W + 2) / (W + 1 + 2D) = (5 + 2) / (5 + 1 + (2 x 3)) = 0.58 7.4. MINIMUM FIELD LENGTH (L) = (ABSORPTIONS AREA / W) x SIZE FACTOR = (1,250 SF / 5 FT) x 0.58 = 145 FT 7.5. MINIMUM FIELD SIZE IS 5-FEET WIDE, 3-FEET SEWER ROCK, AND 145-FEET LONG. USE TWO TRENCHES AT 75-FEET LONG. MATERIALS SPECIFICATIONS: 1. WASTEWATER DISPOSAL SYSTEM COMPONENTS AND MATERIALS SHALL BE APPROVED BY THE MOA IN ACCORDANCE WITH THE CURRENT EDITION OF MOA'S PUBLICATION "STANDARDS AND SPECIFICATIONS FOR COMPONENT PARTS AND MATERIALS USED IN CONSTRUCTION OF ON-SITE WASTEWATER DISPOSAL SYSTEMS". 2. COMPONENTS INCIDENTAL TO THE SEPTIC SYSTEM INCLUDING BUT NOT LIMITED TO PIPING, FITTINGS, PUMPS AND VALVES THAT ARE LISTED OR LABELED BY A MOA APPROVED ACCREDITED THIRD PARTY LISTING AGENCY FOR THE INTENDED USE DO NOT REQUIRE THE MOA SUBMITTAL/APPROVAL PROCESS. 3. SEPTIC TANKS SHALL BE CONSTRUCTED FROM DURABLE, CORROSION-RESISTANT MATERIALS, INCLUDING CONCRETE, FIBERGLASS, OR PLASTIC. SEPTIC TANKS CONSTRUCTED FROM STEEL SHALL BE COATED ON BOTH THE INTERIOR AND EXTERIOR WITH AN APPROVED POLYURETHANE LINING OR SUPERIOR MATERIAL. 4. ALL SEPTIC TANKS SHALL BE FITTED WITH WATERTIGHT COUPLINGS, APPROVED BY MOA, AT THE PUMP-OUT ATTACHMENTS AND ON THE INLET AND OUTLET OF THE TANK. 5. A SEPTIC TANK SHALL HAVE A 20" MINIMUM DIAMETER MANWAY RISER SERVING THE FIRST COMPARTMENT. THE RISER, INCLUDING THE COVER, SHALL BE INSULATED WITH 4" MINIMUM INSULATION EXTENDING 48" BELOW GRADE OR TO THE TANK INSULATION. THE INSULATION SHALL BE OF AN APPROVED TYPE SUITABLE FOR BELOW GRADE APPLICATIONS. EXPOSED INSULATION ABOVE GRADE SHALL BE PROTECTED FROM UV DAMAGE. THE RISER LID SHALL BE SECURED TO PREVENT UNINTENDED ACCESS. 6. PIPE AND FITTINGS SHALL BE IN ACCORDANCE WITH NOTE 1 AND "PIPE AND FITTINGS MATERIAL" TABLE. 7. PIPES USED IN GRAVITY DISPOSAL SYSTEMS SHALL BE 4" IN DIAMETER. 8. CLEAN OUTS SHALL BE LONG SWEEP. 9. SEWER ROCK/DRAIN ROCK SHALL BE COARSE, WASHED AGGREGATED THAT MEASURES 12" TO 2" IN DIAMETER WITH NO MORE THAN 1% PASSING THE No. 200 SIEVE. 10. BEDDING MATERIAL FOR SEPTIC TANKS SHALL BE PER MANUFACTURER'S REQUIREMENTS. 11. FILTER FABRIC USED AS A SILT BARRIER IN THE CONSTRUCTION OF ABSORPTION FIELDS SHALL BE A PERMEABLE GEOTEXTILE APPROVED FOR THE APPLICATION. 12. INSULATION USED IN THE CONSTRUCTION OF SEPTIC SYSTEMS FOR THE PURPOSES OF FREEZE PROTECTION OF DISPOSAL FIELDS AND SEPTIC SYSTEM COMPONENTS SHALL BE MINIMUM TYPE IV EXTRUDED OR EXPANDED POLYSTYRENE, 25 PSI COMPRESSIVE STRENGTH. PIPE AND FITTINGS MATERIAL PIPE TYPE OR ASTM DESIGNATION APPROVED AS PERFORATED DISPOSAL FIELD PIPE OR SOLID COLLECTOR PIPE APPROVED AS CLEAN OUT OR STANDPIPE CAST IRON **YES YES ASTM D3034 (PVC)YES YES ASTM F789 (PVC)YES YES ASTM D1785 (PVC)**YES YES ASTM D2665 (PVC)**YES YES ASTM D2751 (ABS)YES NO* ASTM D2661 (ABS)**YES YES ASTM F628 (ABS)**YES YES ASTM F810 (HDPE)YES NO * D2751 MAY BE APPROVED AS STANDPIPE MATERIAL IF THE MINIMUM WALL THICKNESS IS 0.18", SDR 23.5. ** UNDERGROUND DWV PIPE MATERIALS LISTED IN UPC TABLE 701.1 (2012). CONSTRUCTION SPECIFICATIONS: 1. SEPARATION DISTANCES AS IDENTIFIED IN THE "SEPARATION DISTANCES" TABLE SHALL BE MAINTAINED. NOTIFY THE ENGINEER OF DISCOVERIES MADE DURING CONSTRUCTION THAT IMPACT SEPARATION DISTANCE REQUIREMENTS. 2. FLAG AND SURVEY ALL PROPERTY LINES, WELL RADII, AND EXISTING FIELD SEPARATIONS PRIOR TO START OF CONSTRUCTION. 3. LAYOUT ALL FIELD COMPONENTS AND LOCATIONS PRIOR TO START OF CONSTRUCTION. NOTIFY THE ENGINEER IF CONFLICTS EXIST. 4. GROUNDWATER MONITOR TUBES SHALL REMAIN IN PLACE UNTIL CONSTRUCTION BEGINS. ABANDON GROUNDWATER MONITOR TUBES BY CUTTING ONE FOOT BELOW GRADE AND ABANDON IN PLACE. IF THE GROUNDWATER MONITOR TUBE IS WITHIN FIVE FEET OF THE DISPOSAL FIELD, REMOVE THE GROUNDWATER MONITOR TUBE IN IT'S ENTIRETY. 5. TANKS WITH TWO TO FOUR FEET OF COVER SHALL BE INSULATED WITH A MINIMUM OF 2" OF APPROVED INSULATION PLACED IMMEDIATELY ABOVE THE TOP OF THE TANK. TANKS SHALL NOT HAVE LESS THAN TWO FEET OF COVER. 6. A SEPTIC TANK SUBJECT TO BUOYANCY FORCES SHALL BE ANCHORED OR BALLASTED AS REQUIRED TO PREVENT FLOTATION REGARDLESS OF THE LIQUID LEVEL IN THE TANK. 7. A SEPTIC TANK SHALL HAVE A 4" MINIMUM STAND PIPE PROVIDING ACCESS TO OTHER COMPARTMENTS NOT SERVED BY THE MANWAY RISER. 8. PROVIDE AIR TIGHT CAPS ON ALL CLEAN OUTS AND MONITORING TUBES. 9. PROVIDE A BUILDING CLEAN OUT INSTALLED ONE TO FOUR FEET FROM THE BUILDING FOUNDATION. 10. A DOUBLE CLEAN OUT SHALL BE PROVIDED WITHIN TEN FEET OF THE SEPTIC TANK OUTLET. THE OPPOSING CLEAN OUTS SHALL BE ORIENTED SUCH THAT THE CLEAN OUT CLOSEST TO THE TANK SHALL BE TO CLEAN THE LINE AWAY FROM THE SEPTIC TANK, AND THE CLEAN OUT FURTHEST FROM THE TANK SHALL BE ORIENTED TO ALLOW CLEANING TOWARD THE SEPTIC TANK. THE CLEANOUTS SHALL BE LOCATED ON UNDISTURBED SOIL. 11. SINGLE SEGMENTS OF SUBSURFACE DISPOSAL FIELDS SHALL NOT EXCEED 100 FEET IN LENGTH. 12. THE LONG AXIS OF A DISPOSAL FIELD SHALL FOLLOW THE CONTOURS OF THE ORIGINAL GROUND. 13. THE HORIZONTAL SEPARATION DISTANCE BETWEEN THE CLOSEST EDGES OF WORKING OR DECOMMISSIONED SUBSURFACE DISPOSAL FIELDS, OR SEGMENTS OF SUBSURFACE DISPOSAL FIELDS, SHALL BE AT LEAST TWICE THE DEPTH OF THE DRAIN ROCK BELOW THE LEVEL OF THE DRAINPIPE, BUT NOT LESS THAN SIX FEET. 14. THE BOTTOM OF THE TRENCH SHALL BE LEVEL WITHIN 4". THE BOTTOM OF A WIDE TRENCH OR BED DISPOSAL FIELD SHALL BE LEVEL WITHIN 2" BEFORE PLACEMENT OF DRAIN ROCK. 15. AFTER EXCAVATION HAS EXPOSED THE DESIGNATED INFILTRATIVE SURFACE, ANY NATIVE SOIL THAT IS SMEARED SHALL BE SCARIFIED TO IMPROVE ITS POROSITY BEFORE PLACEMENT OF DRAIN ROCK. 16. PERFORATED DISTRIBUTION PIPE USED IN A SUBSURFACE DISPOSAL FIELD SHALL BE LAID LEVEL AND BEDDED WITH DRAIN ROCK EXTENDING A MINIMUM OF 2" ABOVE THE TOP OF THE DISTRIBUTION PIPE, AND LEVEL ACROSS THE ENTIRE WIDTH OF THE DRAIN FIELD. 17. NON-PRESSURIZED SUBSURFACE DISPOSAL FIELD PIPING SHALL HAVE A 4" DIAMETER CLEAN OUT CONNECTED TO BOTH ENDS OF EACH PERFORATED SEGMENT. CLEANOUTS WITHIN 20 FEET AND IN LINE WITH THE DOUBLE CLEAN OUT DOWNSTREAM OF THE SEPTIC TANK MAY BE OMITTED. 18. AT LEAST ONE 4" DIAMETER MONITORING TUBE SHALL BE INSTALLED IN EACH SEPARATE DISPOSAL FIELD SEGMENT TO ALLOW MEASUREMENT OF THE FLUID LEVEL IN THE DISPOSAL FIELD. MONITOR TUBES SHALL NOT BE CONNECTED TO THE DISTRIBUTION PIPE NETWORK. THE PORTION OF A MONITOR TUBE EXTENDING DOWN FROM THE LEVEL OF THE HORIZONTAL DISTRIBUTION PIPES TO THE BOTTOM OF THE DRAIN ROCK SHALL BE PERFORATED. THE PORTION OF THE MONITOR TUBE ABOVE THE HORIZONTAL DISTRIBUTION PIPES SHALL BE NON-PERFORATED. MONITOR TUBES SHALL BE LOCATED AT ALL ANGLE POINTS OF DISPOSAL FIELDS TO MARK THE LOCATION OF THE ABSORPTIONS SYSTEM. PRESSURIZED TRENCH DISPOSAL FIELDS THAT DO NOT HAVE CLEAN OUT PIPES SHALL HAVE A MONITOR TUBE WITHIN ONE FOOT OF EACH END OF INDIVIDUAL TRENCH SEGMENTS. PRESSURIZED BED DISPOSAL FIELDS THAT DO NOT HAVE CLEAN OUT PIPES SHALL HAVE A MONITORING TUBE WITHIN ONE FOOT OF EACH CORNER OF THE BED. 19. AN APPROVED PERMEABLE GEOTEXTILE SILT BARRIER SHALL BE INSTALLED COVERING THE ENTIRE TOP SURFACE OF THE DRAIN ROCK PRIOR TO BACKFILL. 20. THE DISPOSAL FIELD COVER SHALL BE A MINIMUM OF TWO FEET DEEP, OVER THE TOP OF THE DRAIN ROCK. IF THE DISPOSAL FIELD COVER IS LESS THAN THREE FEET, THE DISPOSAL FIELD SHALL BE INSULATED WITH 2" OF APPROVED RIGID BOARD INSULATION. MINIMUM SOIL COVER OVER THE INSULATION SHALL BE ONE FOOT. 21. THE FINISH GRADE OVER A SUBSURFACE DISPOSAL FIELD SHALL BE MOUNDED A MINIMUM OF 6" ABOVE ADJACENT GROUND TO PREVENT THE FORMATION OF A DEPRESSION AFTER THE BACKFILL HAS SETTLED. 22. UPON COMPLETION OF CONSTRUCTION ALL CLEAN OUTS AND MONITOR TUBES SHALL BE ABOVE FINAL GRADE A MINIMUM OF TWO FEET, A MAXIMUM OF 4 FEET, BE WATER TIGHT, AND LOCATED BY SWING-TIE MEASUREMENTS TO ALLOW YEAR-ROUND LOCATION AND ACCESS. SEPARATION DISTANCES SEPTIC TANK SOIL ABSORPTION SYSTEM PROPERTY LINE 5 FEET 10 FEET WATER MAIN/WATER SERVICE LINE 10 FEET 10 FEET BUILDING FOUNDATION 10 FEET 10 FEET DECKS/STAIRS >30" ABOVE GRADE 5 FEET 10 FEET SURFACE WATER 100 FEET 100 FEET PRIVATE WELL 100 FEET 100 FEET PUBLIC WATER SUPPLY SEE 18 AAC 80 SEE 18 AAC 80 >25% SLOPE >10' TALL -50 FEET >25% SLOPE <10' TALL -25 FEET SUBSURFACE DRAIN -GREATER OF 10 FEET OR TWO TIMES GRAVEL DEPTH SOIL ABSORPTION SYSTEM -GREATER OF 6 FEET OR TWO TIMES GRAVEL DEPTH WATER TABLE -4 FEET IMPERMEABLE LAYER -6 FEET INSPECTIONS: 1. AN ON-SITE WASTEWATER DISPOSAL SYSTEM SHALL NOT BE BACKFILLED, COMPLETED, OR USED UNTIL THE ENGINEER HAS INSPECTED AND TAKES NO EXCEPTION TO THE INSTALLATION. 2. NOTIFY THE ENGINEER 48 HOURS IN ADVANCE OF ANTICIPATED CONSTRUCTION. 3. THE ENGINEER WILL MEET WITH THE CONTRACTOR PRIOR TO CONSTRUCTION TO DISCUSS THE FOLLOWING, 3.1. PRECONSTRUCTION MEETING TO DISCUSS CONSTRUCTION PROCEDURES AND DESIGN REQUIREMENTS. 3.2. VERIFY SITE CONDITIONS CONFORM TO THE DESIGN PLANS AND PERMIT. 3.3. VERIFY THE PROJECT LAYOUT CONFORMS TO THE DESIGN PLANS AND PERMIT. 4. THE ENGINEER SHALL PERFORM A BOTTOM OF HOLES INSPECTION FOR THE SEPTIC TANK AND DISPOSAL FIELD. 5. THE DISPOSAL FIELD REQUIRES THE FOLLOWING INSPECTIONS, 5.1. AFTER EXCAVATION OF ALL NATIVE MATERIAL HAS BEEN COMPLETED, BUT PRIOR TO PLACEMENT OF FILTER SAND AND/OR DRAIN ROCK. THE PURPOSE OF THIS INSPECTION IS TO ALLOW VERIFICATION THAT THE NATIVE MATERIAL CONFORMS TO THE SOILS LOG AND THE EXCAVATION IS TO THE CORRECT DEPTH. 5.2. AFTER THE PLACEMENT OF FILTER SAND, IF UTILIZED. 5.3. AFTER THE PLACEMENT OF DRAIN ROCK, AND INSTALLATIONS OF DISTRIBUTION LINES, CLEAN OUTS, AND MONITOR TUBES, BUT PRIOR TO PLACEMENT OF INSULATION, SILT BARRIER, OR BACKFILL. 5.4. AFTER THE SYSTEM HAS BEEN BACKFILLED TO VERIFY FINAL GRADING AND THE LOCATION OF ALL STAND PIPES. 6. THE SEPTIC TANK REQUIRES THE FOLLOWING INSPECTIONS, 6.1. AFTER THE TANK IS SET IN PLACE WITH DISTRIBUTION PIPES AND CLEAN OUTS INSTALLED, BUT PRIOR TO BACKFILL. 6.2. AFTER THE TANK HAS BEEN BACKFILLED TO VERIFY FINAL GRADING, ELECTRICAL EQUIPMENT INSTALLATION, AND THE LOCATION OF ALL STAND PIPES. Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP241054, Deb Wockenfuss, 05/23/24 TH TH TH OLSON HEIGHTS BLOCK 1, LOT 2 OLSON HEIGHTS BLOCK 1, LOT 3 McCABE WEST LOT 4 PROPOSED 5-BEDROOM HOUSE RESERVE FIELD PROPOSED DRIVEWAY 90 °22.5° 22.5°SPLT TE E TE E P- 1 P- 2 P-3 P-4 P-5 P-6 P-9 P-8 P-11 P-7 P-10 5' 6' 5' 10 ' 10' 10 . 2 ' 10 ' R 1 0 0 ' 75' CO CO DCO BCO 1,500-GAL SEPTIC TANK MT MT TH-01 TH-02CUT MT 1' BELOW GRADE, ABANDON IN PLACE. FULLY REMOVE MT DURING RESERVE FIELD CONSTRUCTION REMOVE MT DURING FIELD CONSTRUCTION FLOW SPLITTER TH-03 RESERVE FIELD FILL LIMITS, DO NOT CROSS PROPERTY LINE 20 ' 54' FINAL GRADING FILL LIMITS, DO NOT CROSS PROPERTY LINE COORDINATE INSTALLATION OF BUILDING SEWER WITH HOUSE CONSTRUCTION 385.14 Septic System 375 380 385 390 395 375 380 385 390 395 0+00 0+10 0+20 0+30 0+40 0+50 0+60 0+70 0+80 0+90 1+00 90° 22.5° 22.5° 20"Ø MIN, INSULATED RISER 2' MIN, TYP 4"Ø CLEAN OUT, TYP 4"Ø BUILDING CLEAN OUT 4" COMBO WYE, TYP 1,500-GAL SEPTIC TANK EXISTING GROUND SPLT FINISH GRADE TO ENSURE MINIMUM SOIL COVER, TYP P-1 P-2 P-3 P-4 P-5 2" BOARDSTOCK INSULATION, TYP 375 380 385 390 395 375 380 385 390 395 0+00 0+10 0+20 0+30 0+40 0+50 0+60 0+70 0+800+84 3' MT PERFORATED IN DRAIN ROCK TEE 7. 8 ' P-11P-10 ELEV:380.61 PIPE TABLE NAME P-1 P-2 P-3 P-4 P-5 P-6 P-7 P-8 P-9 P-10 P-11 SIZE 4" 4" 4" 4" 4" 4" 4" 4" 4" 4" 4" LENGTH 10.89' 6.38' 4.00' 15.23' 39.65' 5.50' 37.50' 37.50' 5.50' 37.50' 37.50' SLOPE 2.00% 2.00% 2.00% 2.00% 2.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% INLET LOCATION N:2593759.0414 E:1675434.7169 N:2593759.0244 E:1675417.0972 N:2593759.0182 E:1675410.7169 N:2593763.0182 E:1675410.7169 N:2593777.0922 E:1675416.5466 N:2593816.7380 E:1675416.3561 N:2593816.7116 E:1675410.8562 N:2593816.7116 E:1675410.8562 N:2593816.7380 E:1675416.3561 N:2593816.7644 E:1675421.8560 N:2593816.7644 E:1675421.8560 INLET ELEV 385.29 384.91 384.78 384.70 384.40 383.61 383.61 383.61 383.61 383.61 383.61 OUTLET LOCATION N:2593759.0162 E:1675423.8300 N:2593759.0182 E:1675410.7169 N:2593763.0182 E:1675410.7169 N:2593777.0922 E:1675416.5466 N:2593816.7380 E:1675416.3561 N:2593816.7116 E:1675410.8562 N:2593779.2120 E:1675411.0363 N:2593854.2111 E:1675410.6760 N:2593816.7644 E:1675421.8560 N:2593779.2648 E:1675422.0362 N:2593854.2640 E:1675421.6759 OUTLET ELEV 385.07 384.78 384.70 384.40 383.61 383.61 383.61 383.61 383.61 383.61 383.61 375 380 385 390 395 375 380 385 390 395 0+460+50 0+60 0+70 0+80 0+90 1+00 1+10 1+20 1+30 4" SWEEP 90, TYP SILT BARRIER, TYP 4"Ø PERFORATED PIPE, TYP3' SEWER ROCK, TYP TEE FINISH GRADE TO ENSURE MINIMUM SOIL COVER, TYP P-7 P-8 2" BOARDSTOCK INSULATION, TYP FI L E P A T H : C : \ U s e r s \ c o l l e \ O n e D r i v e - A K B u i l t C o n s t r u c t i o n & D e s i g n \ A K B u i l t \ P r o j e c t s \ 0 0 3 1 . 0 1 W i l s o n O l s o n H e i g h t s B l k 3 L o t 1 \ A C A D \ 0 0 3 1 . 0 1 - S e p t i c P l a n . d w g PL O T D A T E : 5 / 1 4 / 2 0 2 4 AK BUILT CONSTRUCTION & DESIGN, LLC PO BOX 771203 EAGLE RIVER, AK 99577 (907)854-9115 CERTIFICATE OF AUTHORIZATION #204451 OL S O N H E I G H T S , B L O C K 1 , L O T 3 SE P T I C S Y S T E M D E S I G N AN C H O R A G E , A L A S K A AK B U I L T P R O J E C T N O : 0 0 3 1 . 0 1 SA M A N T H A & K E N D A L L W I L S O N 3OF SHEET: 5/14/2024 DATE: SHEET TITLE: Robert Colles, PE No. CE-163739REGISTEREDPROFESSIONALE N GINEER 5/14/2024 BUILDING (P) SEPTIC SYSTEM (P) WELL RADIUS (E) PROPERTY LINE EASEMENT LEGEND: 00 10' 20' N SEPTIC SYSTEM DESIGN 3 SEPTIC SYSTEM SEWER LINE SEPTIC SYSTEM - EAST TRENCH ABBREVIATIONS: BCO BUILDING CLEAN OUT BOH BOTTOM OF HOLE (TEST HOLE) CO CLEAN OUT DCO DOUBLE CLEAN OUT E EASTING (E) EXISTING ELEV ELEVATION GAL GALLON MIN MINIMUM MT MONITORING TUBE N NORTHING (P) PROPOSED TH TEST HOLE TYP TYPICAL NOTES: 1. PIPE LENGTHS ARE ESTIMATED AND PROVIDED FOR REFERENCE ONLY. CONTRACTOR TO VERIFY MATERIAL QUANTITIES. 2. UNIFORMLY GRADE THE SITE UPON COMPLETION OF SEPTIC SYSTEM INSTALLATION. MOUND MATERIAL TO ALLOW FOR SETTLEMENT OF DISTURBED AREAS AND TO MEET MINIMUM SOIL COVER REQUIREMENTS. ENSURE FILL DOES NOT CROSS PROPERTY LINE. GRADE SLOPES AT 3H:1V. 3. TOPSOIL AND SEED DISTURBED AREAS WITH 4" MINIMUM OF TOPSOIL AND A SEED APPROPRIATE FOR THE SITE. 4. RESERVE FIELD IS BED STYLE SYSTEM WITH SAND LINER. CONTRACTOR TO SUPPLY EQUIPMENT OF SUFFICIENT SIZE TO PREVENT MOVEMENT OF EQUIPMENT ACROSS IN-SITU MATERIALS UNDER SEWER ROCK AT TIME OF FIELD CONSTRUCTION. 5. COORDINATE HOUSE SITE GRADING WITH HOUSE CONSTRUCTION. ENSURE SUFFICIENT SOIL COVER IS PROVIDED OVER BUILDING SEWER. SEPTIC SYSTEM - WEST TRENCH Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP241054, Deb Wockenfuss, 05/23/24 TH TH TH KENDALL & SAMANTHA WILSON OLSON HEIGHTS, BLK 1 LT 3 4/5/24 SEC. 27, T12N, R3W, SM ROBERT COLLES, PE 5/13/24 TH-01 TH-02 TH-01 CHARACTERISTICS REPRESENTED THIS SHEET. 5/13/24 X X 1 2 3 4 5 4/5/24 4/5/24 4/5/24 4/5/24 4/5/24 0:30 1:00 1:30 2:00 2:30 0:30 18 18" 2 38" 0:30 17 14" 1 12" 0:30 16 11 16" 15 16" 0:30 16 34" 1" 0:30 16 34" 1" 30 6" 4.5 5 12' N/A NO AK BUILT OL SM W/ GRAVEL BOH Robert Colles, PE No. CE-163739REGI STEREDPROFES S I O N A L E N GINEER 5/13/2024 TH-03 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP241054, Deb Wockenfuss, 05/23/24 TH TH TH KENDALL & SAMANTHA WILSON OLSON HEIGHTS, BLK 1 LT 3 4/5/24 SEC. 27, T12N, R3W, SM 4/12/24 TH-02 CHARACTERISTICS REPRESENTED THIS SHEET. PERCOLATION RATE 5/13/24 X X AK BUILT ROBERT COLLES, PE 1 4/5/24 - <0:30 DRY - 4.5' 7' YES Robert Colles, PE No. CE-163739REGI STEREDPROFES S I O N A L E N GINEER 5/13/2024 2 4/5/24 - <0:10 DRY - 3 4/5/24 - <0:05 DRY - <1 6" 3.5 4 FASTER THAN 1 MIN/IN. OL SP W/ GRAVEL BOH TH-01 TH-02 TH-03 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP241054, Deb Wockenfuss, 05/23/24 TH TH TH KENDALL & SAMANTHA WILSON OLSON HEIGHTS, BLK 1 LT 3 4/26/24 SEC. 27, T12N, R3W, SM ROBERT COLLES, PE 4/26/24 TH-01 TH-02 TH-03 CHARACTERISTICS REPRESENTED THIS SHEET. PERCOLATION X X 1 2 3 4 5 4/26/24 4/26/24 4/26/24 4/26/24 4/26/24 <1 6" 3.5 4 6' YES AK BUILT OL GP-GM BOH Robert Colles, PE No. CE-163739REGISTEREDPROFESSIONALE N GINEER 4/26/2024 TH-03 - <0:30 DRY - - <0:10 DRY - - 0:07 DRY 6" - 0:06 DRY 6" - 0:07 DRY 6" - 0:07 DRY 6"6 4/26/24 - 0:06 DRY 6"7 4/26/24 RATE IS 0-1 MIN/IN. TEST PIT DUG FOR PERCOLATION DATA ONLY. GROUNDWATER SEEP NOTED AT BOTTOM OF HOLE. VERIFY GROUNDWATER AT CONSTRUCTION. Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP241054, Deb Wockenfuss, 05/23/24 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP241054, Deb Wockenfuss, 05/23/24