MUNICIPALITY OF ANCHORAGE
On -Site Water & Wastewater Program
PO Box 196650 4700 Elmore Road
Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997
http://www.muni.org/onsite
On -Site Water & Wastewater System Permit
Permit Number: OSP241100 Effective Date:
Work Type: WellSeptic Initial Expiration Date:
Tax Code Number: 01746233000
Site Legal Address: TAILWIND LT 2 G:2834
Site Mailing Address:
Owner: TREVITHICK ERIC Lot Size in Sq Ft:
Design Engineer: F0 (Z-G E- Total Bedrooms:
This permit is for the construction of:
c
U(
t�NpavtIII U11t
5/30/2024
5/30/2025
44636
Q Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy Q Private Well ❑ Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
Received By: I ��
Issued By:
Date:
Date:
5
HcI=�OOn
Community Development Department
Development Services Division
On -Site Water & Wastewater Program
Phone: 907-343-7904
Fax: 907-343-7997
ON -SITE SEWER/WELL PERMIT APPLICATION
Parcel I.D. 017-462-33
Property owner(s) Eric TreyithiCk Day phone (907) 301-5359
Mailing address P.O. Box 230534, Anchorage, AK 99523
Site address 12700 Gander Street, Anchorage, AK 99516
Legal description (Sub'd., Block & Lot) Tailwind Lot 2
Legal description (Township, Range & Section)
Lot Size 44,636 Sq. Ft. Number of Bedrooms 5
APPLICATION IS FOR:
APPLICATION IS AN:
TYPE OF DWELLING:
(® all that apply)
Absorption Field
❑x
Initial 0
Single Family (SF) ❑x
(w/wo ADU)
Septic Tank
0
Upgrade ❑
Duplex (D) ❑
Holding Tank
❑
Renewal ElMultiple
Dwellings ❑
Privy
❑
(SF and/or D)
Private Well
0
Water Storage
❑
THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
(Signature of property owner or authorized agent)
P Perm'
Fees: Waiver Fees:
Payment: 517-b L+ Date of Payment:
Receipt Number: — 0 S92 D Receipt Number:
Permit No. 622-41(00 Waiver No.
Permit App__• : ,'_..:c
May 17, 2024
MOA Development Services, On-Site Water & Wastewater Program
4700 Elmore Rd
Anchorage, AK 99507
Subject: Tailwind Lot 2 – 12700 Gander St
Septic system design
Dear On-Site Services Engineer:
The owner of the above lot intends to build a 5-bedroom home on the property, so we are
submitting this permit application for the construction of a new well and septic system. The
attached site plan identifies the location of the home as well as the proposed well, septic location
and alternate site. No conflicts exist between this proposed system and any other well or septic
system, whether on this lot or adjacent lots.
The ground surface on the lot fairly uniformly toward the southwest, at between a 10-15% slopes.
The slopes do approach 20% in some areas, but there are there are no slopes greater than 25%
within 50 feet downslope of either the primary or alternate site. Contours are shown on the site
plan showing the grade and direction of flow. Stormwater drainage will not impact this septic
system. The new trench will be constructed parallel to the slope as much as possible.
Wells on this and adjacent lots are shown. The new system will be a minimum of 100’ from all
wells and surface water, and more than 5’ away from the septic tank. The alternate site is located
more than 6’ away. Please refer to the attached test hole log, plan and profile pages for the septic
design. If this design is followed, there will be no adverse impacts to adjacent properties.
Sincerely,
Benjamin Schiller, PE
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP241100, Curtis Townsend, 05/30/24
Depth
(Feet)
1-
2-
3-
4-
5-
6-
7-
8-
9-
10-
11-
12-
13-
14-
19-
20-
FT AND FT
I
(ENGINEER'S SEAL)
Performed For:
Legal Description:
15-
16-
PERC HOLE DIAMETER
Date Gross Time
Slope Site Plan
PERCOLATION RATE (minutes/inch)
Net Time Depth to Water Net DropReading
COMMENTS
TEST RUN BETWEEN
17-
18-
PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE:
CERTIFY THAT THIS TEST WASPERFORMED BY:
(907)343-7904
Soils Log - Percolation Test
Township, Range, Section:
WAS GROUND WATER
ENCOUNTERED?
IF YES, AT WHAT DEPTH?
S
L
O
P
E
Date:
Depth to Water After
Monitoring?
Date Performed:
Municipality of Anchorage
Development Services Department
On-Site Water and Wastewater Section
4700 Elmore St.
P.O. Box 196650 Anchorage, AK 99519-6650
www.muni.org/onsite
Tailwind Subdivision, Lot 2
7.22.23
No
N/A
NGWE
10.12.23
<1 6"
2 3
Added approx 2 gal of water in less than one min, all water absorbed in less than 4 min. Added approx 2 gal of water in less than one min,
all water absorbed in less than 5 min.
Triad Engineering, LLC Grant Mathews
10.12.23
S e e a t t a c h e d
s i t e p l a n
Land LLC
Organics, root mat
Silty sand, brown, SM
Sand w/ trace silt
gray-brown, SP
BOH
NGWE
Silt w/ sand, tan, dense
ML
TH-1
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP241100, Curtis Townsend, 05/30/24
ALTERNATE SITE
CAT III 25' LONG X 5" WIDE, 0.5'
EFFECTIVE DEPTH
Benjamin Schiller
CE 12592REGISTEREDPROFESSION A L E N GINEER
1"=40'
(2) 75' LONG x 5' WIDE, 0.5'
EFFECTIVE DEPTH
ABSORPTION TRENCHES
NEW 1500-GAL
SEPTIC TANK w/
20" MANWAY
CO - CLEANOUT
2CO - DOUBLE CLEANOUT
FCO - FOUNDATION CLEANOUT
FS - FLOW SPLITTER VALVE
MH - MANHOLE
MT - MONITORING TUBE
SV - SEPTIC VENT
TH - TEST HOLE
LEGEND
TAILWIND, LOT 2
FEET
0 40 80
5-BDRM HOME
SEPTIC PLAN
5/16/24
Flyaway Avenue
Ga
n
d
e
r
S
t
r
e
e
t
10
'
U
T
I
L
I
T
Y
E
A
S
E
M
E
N
T
DRIVEWAY
DRIVEWAY
280
290
300
FCO
MT
MT
MT
MT
TH
PUMP VAULT
≥6'
EXISTING WELL
NEIGHBORING WELL
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP241100, Curtis Townsend, 05/30/24
TAILWIND, LOT 2
TYPICAL TRENCH SECTION
(NO SCALE)
NOTES:
1. GRADE AREA OVER TRENCH TO DRAIN AWAY
2. PROVIDE 3' OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2'
WITH 2" OF INSULATION
3. CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER
THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY
Benjamin Schiller
CE 12592REGISTEREDPROFESSION A L E N GINEER
2'
2'
DESIGN FACTORS:SYSTEM REQUIREMENTS:
750 GPD PEAK FLOW
PERK RATE: <1 MIN/IN
APPLICATION RATE: 1.0 GPD/SF
5-WIDE TRENCH SYSTEM
1,500-GAL SEPTIC TANK
w/ PUMP VAULT
BOTTOM OF TRENCH: AT ORIGINAL GRADE
FLOW LINE ELEVATION: 6" ABOVE GRADE
750 GPD / 1.0 GPD/SF (/ 5' WIDE * 1.0 RED FACTOR [0.5 DEEP]) = 150' LF TRENCH REQUIRED
(2x 75' LF SPECIFIED)
GEOTEXTILE FABRIC &
2" FOAM INSULATION 1 1
4" PVC w/ 20 - 1
8"
ORIFICES EVENLY
SPACED @ 7.5' OC
6"
5/16/24
5'
DRAINFIELD ROCK
MOA APPROVED SAND
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP241100, Curtis Townsend, 05/30/24