Loading...
HomeMy WebLinkAboutSPRING BROOK VISTA #1 BLK 1 LT 1Spring Brook Vista #1 Block 1 Lot 1 #050-091-28 Municipality of Anchorage Development Services Department Building Safety Division; On-Site Water 8 Wastewater Program, 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 Page 1 of 3 On-Site Wastewater Disposal System and/or Well Inspection Report Permit Number. SW020238 PID Number. 050-091-28 Name: JERRY LEWIS Wastewater System: 0 New ■ Upgrade Address: 12336 E. PRINCE OF PEACE RD. w EAGLE RIVER, AK 99577 ABSORPTION FIELD Phone: No. of Bedrooms: (907) 250-9958 4 O Deep Trench O Shallow Trench O Bed O Mound O Other LEGAL DESCRIPTION S.11 scans: Total D•Pah Naw agad V GPD/54 R R Block: Lot: Subdivision: D"U, b pipe began Lam anpn01 poet Gravel depth Wn.aln 1 1 SPRING BROOK VISTA #1 rt rt Township: Range: Section: — rl added above 0441,01 Pada' G4eol wkRb:IAn,ber of W. Dwane* bel.ewn WELL: 0 New O Upgrade R I n. Cbe01nooaon PrW% A.&c . Teld cawed Ta TZ pbpprpt" ay. Pipe matobk rt In. 50. R 0 w .. G Dab Ortt# Sblle Mala lives Dob Mnled: P�eO rt r»w ►anp Set Ah ca" N01sM Avow tkw ,F TANK rt L SEPARATION DISTANCES ■Septic 0Holding 0S.T.E.P. ODther To Septic Absorption Field Lift Station Holding Tank bpe/PrMtw sw.sr /love rOCwa' GREER TANK CoPaa10' ti 1250 From Tank Well 100'+ 100'+ — — 25'+ Yotol01: STEEL N w of ao.,pathwab: 2 Surface Water 100'+ 100'+ — — — LIFT STATION Lot Una jb4± F ?C+ — — — al.0 In saeo^c Ya.Aaobwr. amp an Iev01 oL p 011 aE HpN weld akem aL Foundation 5'+ 10'+ — — — Panp Yalu D.&J cd bwpwaaaru pwfor,nwd br: Curtain Drain NONE KNOWN BENCH MARK Remarks: THE EXISTING SEPTIC TANK WAS COMPLETELY ABANDONED. laaaam end DewodpT BOTTOM OF SIDING ® POINT "B" Awsnwd iw two. 1 0.00 p1, ENGINEERS EEA Inspections performed by: AKWWC, INC. Oates: 1st 10/15/2002 . °.'..... . ............. 2nd 10/29/2002 3rd — D0 Q aff y A. Gam es! 7� Development ervices Department Approval QQ —7953 p�� ��4P tee' .......•• 404N Reviewed and approved by Dote: ( ] 4 4p° r tossro %aa" (R«. 17/01) Q4po�OpO %S o! eLP4Nt- %Svcrv-' vNt"\ its OcA60a,r c?Oci C) X14 . PERMIT NUMBER: AS -BUILT DRAWING °ARCEL 050-0 SW020238 050-091 1 ROBERT A P.E. 7/19/1983 TESTRHOLE SEE LETTERS OF v'PROXf AT / NON-OBJE ON ( EXlSnNunD�LOFIELDS ITE E �OC+1TIpN — 10• UTILITY EASNENT /� NEW 1250 GALLON /SEPTIC TANK __. \� CO3 ►(f3 fir. Iuu.uuulwl►l t 7 / / C& C 3 N •R PANNONE. P.E. (/2002 TEST HOLE A B C STI 37.1 19.2 — ST2 43.5 19.2 — QO DBL1 43.5 12.2 — QO DBL2 52.6 52.6 — C01 — 60.0 48.0 \ Q� MT1 — 55.0 42.0 APPROXIMATE pF LOCATION OF CO2 — 58.5 53.0 WATERLINE AND CU MT2 — 60.5 54.5 KEYBOX CO3 40.0 52.5 —� MT3 39.0 52.5 — 11/15/2002 OF �Op E �. DRAWN BY: v. .suo4 ALASKA «TATER & «TASTENNIATI✓R C.J.G. �: 00 CONSULTANTS, INC. 1" — 30' """' 4 "' ..""0 6901 DFFAPG GOAD SUITE MANCNDGAGF. AA 99501 • PNONF f9071331fiA9 • Fe[ f00ADR-17c6 — D PREPARED FOR: PHONE NUMBER: PAGE NUMBER: O. •• ••,••• •.: ••. 0 JERRY LEWIS (907) 250-9958 2 OF 3 QO ff A. Garn s: �O LEGA. DESCRIPTION:QO gJ '7 `Fv� LOT 1, BLOCK 1; SPRING BROOK VISTA SUBDIVISION #1 0n qv TYPE OF WORK: u44Odplo Tesslo"ear AS -BUILT DRAWING FOR SEPTIC TANK UPGRADE �40000�� PERMTTNUMBER° ASBUILT DRAWING PARCEL ID NUMBER: SW0 AS—BUILT 050-091-28 TOP OF TANK A INLET - 94.84 INVERT OF BUNG J AT INLET - 94.33 FINAL OWE - 98.84+ TOP OF TANK AT n /-CUTLET - 94.80 NEW 1250 GALLON SEPTIC TANK INVERT OF BUNG AT OUTLET - 94.06 11/15/2002 o f F... • ..... q pp DRAWN BY: C.J.G. 4 �'. ...... _. .. 1 �- ALASKA NATER & WASTE WATER o9 vl SCALED CONSULTANTS, INC. 6001 DFRARR ROAD. SURF 2R • ANCRDRA6F. A8 04S0A • FRONF (001)53)4110 • FAX (007)338-1766 1 = 30• ....... . ........... O PREPARED FOR: PHONE NUMBER: PAGE NUMBER: JERRY LEWIS (907) 250-9958 3 OF 3 v •,,1 fr Go es Q $. E 953 .G ppp0O°0d pro . .....o aa�Oa �40000� LEGAL DESCRIPTION: LOT 1. BLOCK 1; SPRING BROOK VISTA SUBDIVISION #1 TYPE OF W PROFILE AS—BUILT OF NEW SEPTIC TANK Municipality of Anchorage Page I of z DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 • Anchorage, Alaska 99519-6650 • Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report Permit Number: -;LJ (220Z3,q5 PID Number: _0c;-0r-)g124 Name: Z t2(Z- Lzors Wastewater System: ❑ New ❑ Upgrade Addres 3 A+ve-4 Air- 9q S/ ABSORPTION FIELD Phone: Z — % s No. of Bedrooms: ((�� ❑ Deep Trbn` ❑ Shallow Trench ❑ Bed h4aL4- ❑Other LEGAL DESCRIPTION Soil Rating: Total original grade: GPD/Sq. Ft. r Lot: I Block: , Subdivision: sPl�rliw O� S /t % a Depth to pipe bottom from original grade: �t. r depth beneath pipe Ft. Township: Rang: Section: Fill added above original grade: brevet length: -WEO • New ❑Upgrade Gravel width: Number oil' es: Distance between lines: �'� Classification (Priya Total D Cased To: Ft. Total absorpti area: Ft. Pipe material: Ft. Ft. Or,'lied: Static Water Level: SO. Ft. Inst r: Date installed: Ft. Yield: Pump Set at: Casing bove Ground: GPM Ft. t. TANK SEPARATION DISTANCES Septic ❑ Holding ❑ S.T.E.P. To From Septic Tank Absorption Lift Holding Public/Private Manufacturer: Capacity In gallons: Field Station Tank Sewer Lines (n Q U� 12 67 Well Material:_ 5/ %L Number of Compartments: Water I0oSurfactl + ►oo' LIFT STATION Lot Line r Size In gallons: Man rer: I N Foundation 5 I "Pump on" level at: leve High water alarm at: i 1-1 CurtainSO Drain / {- SOr T Pump Make — ElectrJicall Inspections performed by: Remarks: BENCH MARK 6W 12 5v C1, If L i �Ir /� Location and Description: /tJSf rr- ,AL� Assumed Elevation: Ft EAL ..........1 ,9s.. Inspections performed b • :QbY /ll(s Dates: l st 101131oz. "''7- - .... 2nd Z>�: . .. ............. �t'; CHRISTOPHER R. WOOD ;fit Department of Heal h and Human Services approval ^i' CE:10387 Reviewed and a b S` D PP Y• Date: ���,��!sstoy�b� �o: 7• gni,% 1[)nv wa11 \A 7G • • � � dpi- SEP rr� . _ r � �' /off • Q � � � �'� s GoM� f� ti en iy • ' �\ 7 • • �o . 1'� feF?'N1 'Pim /� ' � ', � � • 1 • , �� •' • � `;� � el % � '� • Via. d \ �• cr rr"o f� lu o �- (P� pe i.•� 3Tlztc'�-T.� �tv� / Gt .1s{� �'G� �),nl� •SliJT-lllCn TIES � 91t7 ' 100.0 5� vpj C,2oMNt> tAerAC I Z50 C,AL i3 - p lq•5 S6PTTL TAM< vk ELEV),io" vs't� �� P� '•��� ownjt2:J tRRY LL'wj7S P�oPERT y : SPtjrr\jA o(&vr- VTsi 4 L f3 I . rn cH STOPHER R. WOOD �r ~ h CE:10387 ' tom— L/Ti •— � � �' 30 , A' 1 If v 4 e" ' •� QJ • �o . rk' F�,4-ter �,<1'' i� ', , � d • J �ousP � t r � � A , ��I V .� , •� , , , �. \� v\SOF q�► f,1;0 T,4-"49 r ! "49TH : *' �Q •�•d� 7-ro r, -f Q�'T �S� �� Wim./( r. t•...........�. . ..:.. '(Pipe �n sTFztc•E'T.� / �' � �k'.�.�1s ,.. ... /►Gi o ! !'_' lamer Karl .D6wlin4, o / ' � 's �. ;, • 15645•'. � ��i 40FESSIONNI.�'*.a.'' .... It is the'responsibility of the owner to dcterminc•tite / ��\�V►�+ existence of any easements, covenants *Or restrictions which do not appear on the recorded subdivision plat. Under:no cireunutanees'should any data bcrcon be used;for construction or for establishing boundary or B UALT EASEMENTS OF RECORD, OME.R UAN THOSE fence Ira Th s. e surveyor lakci responsibility for tlu SHOWN ON THE RECORDED PLAT,•ARE NOT. Initial transaction only. SHOWN HEREON. LOT- ' . - BLOCK % 0 BRASS CAP MONUMENT. S ic%�3 i/•' -,c_ -,;e i (PLAT NO.: _) O IRON PIPE. ANCHORAGE�RECORDING�DISTRICT V REBARCORNERFOUND. 1 HUBANDTACK PREPAVD BY: DOWLING & ASSOCIATES 1426 Hyder. Street. : Anchorage, Alaska 99501 REyISIONS' DATE BY DATE:/Boc�—pz BY; SCALE: WORK ORDER: FIELD BOOK: GRID NO.: j I i M T//A CALL ON YOUR COMPANY t' *i. _ '..:?.xr• ,•r.'• � ,err NON -OBJECTION TO EASEMENT F,vCROACHMEN-TT!bOCt��1'i�'N'I' By this document Matanuska Telephone Association. Irc. (MTA) ddcy s that it has ro objection to ih.e encroachment of septic vents within the platted 10 foot Utility Easement witliin the northeasterly corner of Lot 3, Block 1, Spring Brook Vista Subdi%,ision. rl, Plat 1v6.'71-10 (71-296), Anchorage Recording District, Anchorage: Alaska. ` �r+�**,;:*re#,!.***it*+k*w>ti�l>k***1�*I��Yw, wa**�!:r:�wY��Y*�k�l:w��lr.,��k*+Mw#+k****>kln>kr:.kw:f�ww�:�:�at�:x:�•�*�f�y,I.wx::r*+k*�:*,.Ix* Please be advised that MTA throusrii the issuance of this document does not forfeit any of its rights to ilhe use oft/he area cited. L7 the exercise of these rights MTA -,M1, if necdcd, upgrade, maintain, repair, andlor rep)ace buried or aerial teleeommuni.cations facilities xithin the casement. Any repairs that ma,� be required to the encroachment as a result of utility construction, will be bome by the property owner of rec'erd. Thisdocument does not authorise the placenient of any additional encroachmentswithin the easemertt arca. This document is, in no wav, vn-aureemen; to vacate any onion of the utility easement and should not be intemretcd as such. Issued for Matanuska Telephone Association, [tic. tlus 30 day of October, 2003, by. i Reai Estate R. Properties Agent TFIIS 1S TO CF.,TZTJFF, that on Us 30th day of October, 2002. before me the undersigned, a liota.ry PiNic in and for the State of Alaska, duly commissioned and sworn as such, personally appeared Becky Glenn known to me. and to me known to be the individual named in and who executed the foregoing instrument and acknowledged to me that he signed and seaied the same as a voluntary act and deed for the uses aT:d purposes thcrc n mentioned. LN V47TNT'SS 'MiER. 0F, I have hereunto set my hand and official seat the day and year f rst• above written. GRAN 70K: ,vlatartuska Telephone Association, Tile. P.O: Box 3550 Falmer. AK 99645 .•moi ..� .• �y. .,K' t.•• ��i�;�,�•• •t� �.; ���4tary Public in and for i vl.y commission expires: ^ GRANTEE: Jerry E. Lewis Sr. 2438 Chilligak Ddvc Anclh; rage AK 9951-:77* Mat?nuska T elephono Acsociat;0n. Inc. P-0- Box 3550 - Palmer, Alaaka 95645-3550 1-800.746.8510o Q07.761 2510 , Fax 907.761.2646 STATEMENT OF NON -OBJECTION FOR ENCROACHMENT WITHIN UTILITY EASEMENT Matanuska Electric Association, Inc. (MEA) has no objection with the location of a s is system and vent pipes as shown on the attached as built drawing within the iftility easement along the north boundary of the following property; . Lot 1, Block 1, Spring Brook Vista Subdivision Unit No. 1, according to Plat No. , 72-149, Anchorage Recording District, Alaska. Situated in Section 1, Township 14 North, Range 2 West, Seward Meridian This non -objection is granted with the full understanding and agreement by all parties having an interest in the above property that this septic system encroachment will in no way restrict or limit the current or future ability of MFA to fully enjoy the benefits of the easement for any and all utility purposes that it presently enjoys ender the easement. ' This -non-objection is further conditioned by the stipulation that MEA will be held harmless from liability for any and all damages to the encroachment that may resLilt from the existing and future use of said easement by MEA. its contractors, successors; agents, licensees, or assigns. Matanuska Electric Association, Inc. General Manager or his Revprebentativo /C) A I,,' Lo Date MEA ACKNOWLEDGMENT STATEF Via=• �����`- Q ALASKA } ta* PURiLic THIRD JUDICIAL DISTRICT'yl,%•�fi�•••••`�; V�'1 il/ The ru1If11C`\i C •u it y y dyieerrieril was• a�knowled�ed before me this day of by Notary Public for theme of Alai e My commission expires: o P October 28, 2002 Julia Hall 12336 E. Prince of Peace Dr Eagle River, Alaska 99577 Dear Mrs. Hall Subject to your agreement to indemnify the company as set forth below, GCI Cable Inc. of Alaska has no objection to the septic system pipes encroaching into the 10' utility easement on the north property line of Lot 1, Block 1, Spring Brook Vista Subdivision. Known as 12336 E. Prince of Peace Drive, in city grid NW252. This letter of non -objection in no way precludes GCI Cable from full use and enjoyment of any. rights it may have within any portion of the utility easement and or the right-of- way, including unlimited access for servicing its facilities. Also any additional and extraordinary costs incurred during any future required construction, repair or reconstruction of GCI's facilities to accommodate any or all of the encroachments shall be paid by the property owner. By signing below, you agree to indemnify and hold GCI Cable harmless, now and forever, for any damage,'costs, expense (including reasonable attorney's fees), liabilities and injury to any person or property occurring as a result of the encroachment. Please indicate your acceptance by signing and returning this letter to myself at the address below. Sincerely, 2 Robert Pringle OSP Design - /,12-- Date 5151 Fairbanks Street 9 Anchorage, Alaska 99503 • 907 / 868-5600 10/24/2002 Mr. Jerry E. Lewis Lewis Enterprises P.O. Box 190963 Anchorage, Alaska 99519 To whom it may concern: ENSTAR Natural Gas Company toN SIGN rF SFMCO ENERGY ng+neer ng Department 401 E. International Airport Road P. O. Box 190288 Anchorage, Alaska 99519-0288 (907) 264.3740 FAX (907) 563-4085 ENSTAR Natural Gas Company has no objection to the encroachment of the Septic System in the 10 -foot utility easement on the north side of Lot 1, Block 1, Spring Brook Vista Subdivision. See attached as -built survey dated 10/18/02. Acceptance and use of this letter of non -objection by yourself, your heirs, your assigns, or your successors, will constitute agreement to the following stipulations: ENSTAR will be held harmless, now and forever for any damages or injury to any person or property as a result of this encroachment. Any ENSTAR facility damaged or destroyed, as a result of this encroachment -will be repaired at no cost to ENSTAR. Any costs incurred by ENSTAR for special construction necessitated by this encroachment will be borne by the property owner. All applicable safety code regulations will be observed and maintained. This letter of nonobjection will in no way preclude ENSTAR from full use and enjoyment of its rights within any portion of its right-of-way. Sincerely, ENSTAR Natural Gas Company Ae Cooper ::...... Engineer..`' '. '::: - _, _ .....:... , i4't. *� .; .. :,' _;,[. � t .fir: `•,( .••. .,... ,t, cc: File, I: -.�..._ ; ti _ !::..` ....', I•. • :,: :�•��,. ,,;�,.�,.r. MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Upgrade Permit Number: SW020238 Legal Description: SPRING BROOK VISTA #1 BLK 1 LT 1 Design Engineer: 0041 AK Water & Wastewater Consultan- Owner Name: Jerry Lewis Owner Address: PO Box 19063 Anchorage , AK 99519-0000 Date Issued: Oct 03, 2002 Expiration Date: Oct 03, 2003 Parcel ID: 050-091-28 Site Address: 012336 PRINCE OF PEACE DR E Lot Size: 16241 SQ. FT. Total Bedrooms: 4 Permit Bedrooms: 4 This permit is for the construction of: ❑✓❑ Disposal Field ❑✓ Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. p l22 f02 SEF F_N(,..I0"P, S /9 Tf19e"Ep ,4M ft AF,0 DF 516 Al 0,4TsD /0/8/02. Received By: Date: 10 3 0� Issued By:� Date: /o 3 10-2 Georrye P. ll'aerch. Mayor 10/3/2002 Alunicipality of Anchorage Building Safety DIVIS1011 Jeffrey A. Gamess, PE Alaska Water & Wastewater Consultants, Inc. 6901 DeBarr Rd. Suite 2B Anchorage, AK 99504 Subject: Waiver Request for Spring Brook Vista #1 Block 1 Lot 1 Waiver Request #WR020073 Parcel ID #050-091-28 Permit 4SW020238 Dear Mr. Garness: Anchorage All -America City I F 2002 Your request for a waiver of the required 10 feet horizontal separation from the absorption field to property line has been approved. The approved separation distance is 1.0 foot. This waiver approval applies to the existing absorption field to property line separation only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. If there are any further concerns or questions regarding this waiver, please call our office at 343-7904. Sincerely, D R• -d' Daniel J. Roth Civil Engineer On -Site Water & Wastewater Program P.O. Ilox 19x650 • Anclorage, Alaska 99519-6650 • Telephone: (907) 343-8301 • Fa:x: (907) 343-8200 4700 South Bragaw Strcct • Anehorage, Alaska 99507 1 itt lr//������•.ci.tuuhora�c.ulc.us WR#: WR020073 Date Received: 1011102 Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907)343-7904 Waiver Review Worksheet PID#:060-091.28 HAM Legal Description: Spring Brook Vista #1 Block 1 Lot 1 Engineer. Jeffrey A. Garness, PE Alaska Water & Wastewater Consultants, Inc. Applicant: Jerry Lewis Waiver Requested: 1 foot from drainfield to southwest lot line Criteria: Geology A. Water Table B. Soil Sorption C. Permeability D. Water Table Gradient E. Horizontal Separation Total: Permit#: SW020238 Points: use* season Waiver is Granted: 0 0 0 Waiver is not Granted: List Conditions or Reasons for above: Date: By: Ntr%e, of Reviewer Rec#: 26361 Amount: 300.00 Date Municipality of Anchorage • -� Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. 050-091-29 Permit Number SW020238 Property owner(s) Jerry Lewis Day phone 250-9958 Mailing address (1) P.O. Box 19063 Mailing address (2) ANchorage, AK Zip Code 99519 Legal description (Lot, Block & Sub'd.) Lot 1. Block 1 Springbrook Vista -41/ Legal description (Section, Township & Range) Lot Size-4Acrel�q.Ft. /0;ZNI THIS APPLICATION IS FOR: Number of Bedrooms 4 Sewer Only ❑ Well Only ❑ Sewer and Well ❑ Water Storage ❑ Sewer Upgrade THIS PROPERTY CONTAINS: Hot Tub ❑ Jacuzzi ❑ Swimming Pool ❑ Water Softening Unit ❑ Therapy Pool [_] I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit Fees: HOOW -� Date of Payment: r7/ ca_ Receipt Number: as (Rev. 12/00) Waiver Fees: Date of Payment: Z• Receipt Number: ALASKA. WATER Ee WASTEWATER •�-rr.rw+.sw..r.r�u.owMw.ua.u�w CONSULTANTS, INC. October 8, 2002 Municipality of Anchorage Development Service Department Building Safety Division On -Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650 Anchorage, Alaska 99519-6650 Ref: Revisions to Septic System Design for Lot 1, Block 1; Spring Brook Vista SID #1 To whom it may concern: A revision to septic upgrade permit (permit# SW020238) was re -issued on October 3, 2002, for a conventional type septic system. During the excavation of the confirmation test hole, the monitoring tube for Steve Pannone's test hole was checked and found the groundwater to be at 8 feet. The confirmation percolation test found the rate to be 40 minutes/inch. Based upon this information, a conventional type septic system will not fit in the area available. We are proposing that a 1250 gallon steel septic tank and a 550 gallon "Fat Albert" pump vault with a dosing timer and a bottomless intermittent sand filter (ISF) be installed. Comments regarding the redesign of the septic system are as follows: DRAINFIELD DESIGN: Bottomless Intermittent Sand Filter (ISF) a. Percolation Rate: 20 & 40 minutes/inch b. Allowable Application Rate for ISF: 2.0 gallons/day/R2 c. Number of Bedrooms: 4 d. Design Flow: 600 gallons per day e. Minimum Absorption Area: 300 ftZ f. Effective Depth below pressure pipes: 2.5+ inches g. Width: 12 feet h. Length: 30 feet. i. Effective absorption area = 360 ftZ j. Air Supply: Thomas Industries, Model 5070, "Anchorage Tank". k. Air Supply Line: "Wasteflow" emitterline, 1/2 inch I.D, "Anchorage Tank". 1. Sand Material: In accordance with M.O.A. latest standards in. Pea Gravel: 100% passing 3/8" sieve, less than 20% passing the 1/4" sieve, and less than 1% passing the #8 sieve. 6901 Debarr Road, Suite 2B " Anchorage, AK 99504 Ph: (907) 337-6179 " Fax: (907) 338-3246 • Website: akwwe.com We are proposing to excavate down to a depth of 4.0 feet (maximum), place a minimum of 6 inches of sand, install the air supply line, and cover it with 1.5 feet of sand. On top of the sand, we will place 6 inches of 3/8 inch pea gravel, with the pressure laterals midway in the layer. We will use a conventional S.T.E.P. (Anchorage Tank), equipped with a programmable timer so that Dow can be intermittently dosed to the ISF. SURFACE NVATERS: There are no surface waters within 100 feet of the proposed design. TOPOGRAPHY: The area for the proposed septic upgrade is a 1 to 5 percent slope running from south to north; in short, there are no slope concerns. We are unaware of any adverse impacts this installation would have on adjacent wells or septic systems. If you have any questions, please contact us at 337-6179. Thank you for your .E., M.S. NOTE. Attached is a revised design drawing, a profile drawing, a soil logs, and a 7 page construction specification letter which are all part of the design package for this septic system. 6901 Debarr Road, Suite 2B * Anchorage, AK 99504 Ph: (907) 337-6179 * Fax: (907) 338-3246 * Website: akwwe.com / \ j AIR / v (SEE STEVEN R. PANNONE. P.E. 6/14/2002 TEST HOLE - EXISTING TANK TO BE I AND REPLACED WITH 1250 GALLON SEPTIC INSTALL FOUNDATION NOTE: THE CONTRACTOR MUST HAVE THE NORTH AND SOUTHWEST PROPERTY LINES FLAGGED BY A REGISTERED LAND SURVEYOR PRIOR TO CONSTRUCTION. THE AIR COWRESS13R SHALL BE LOCATED VITHIN THE BASEMENT OR THE GARAGE, THE CONTRACTOR SHALL PROVIDE A 0-10 PSI PRESSURE GAUGE AT A LOCATION WHICH IS READILY ACCESSIBLE FROM WITHIN THE HOUSE, NOTE, A 30 PSI GAUGE VILL NOT WORK. THE AIR COMPRESSOR SHALL BE A THOMAS INDUSTIES MODEL 5070, AS SUPPLIED BY ANCHORAGE TANK. THE AIR LINE SHALL BE 1/2 INCH DIA. HDPE u PIECE), 'INSULATED WITH 1/2 INCH FOAM PIPE WRAP 023 VALUE). INSIDE A 2 INCH SCK40 PVC JACKET. THE LINE SMALL BE BURIED TO A MINIMUM DEPTH OF 3 FEET. THE CONTROL PANEL FOR THE STEP TANK SHALL BE INSTALLED WITH A AUDIBLE/VISUAL INDICAT62 WITHIN THE BASEMENT OR GARAGE. 550 GALLON G� �Q�� : "• INSTALL AIR COMPRESSOR INSIDE FOUNDATI N •• (SEE NOTE) ., . Q G oAtOR8VISED `oo�Opp / �d O .0 DRAWN DRWN B: a�.. S . _ -11r�..__e� �J.L.M. 4 �QOO ALASKA «'ATER & «'ASSCALE: 4 I �------------CONSULTANTS,INC .�-- 1�. — 30. """' ... „• :.,,•Q 6901 DEBARK ROOD. SUITE 29 • ANCHORAGE. AK 99504 • PHONE (907)337-0179 • FAX (907)338-3246 PREPARED FOR: PHONE NUMBER: PACE NUMBER: JERRY LEWIS(907) 250-9958 1 OF 2 r y G e s LEGAL DESCRIPTION: O 7953 LOT 1. BLOCK 1; SPRING BROOK VISTA SUBDIVISION # y1 �° TYPE OF WORK: 0°O'Profa3slol REVISED DESIGN FOE SEPTIC SYSTEM UPGRADE ��Opppoo CONFIRMATION TEST HOLE AND PERCOLATION PROPOSED BOTTOMLESS INTERMITTENT TEST PERFORMED PRIOR TO ANY EXCAVATION SAND FILTER (ISF) SYSTEM. EXCAVATE A TRENCH THAT IS 4 FEET DEEP — ON UPHILL SIDE BY 12 FEET ROBERT A SHAPER P.E. WIDE BY 30 FEET LONG. ADD 2+ FEET 7/19/1983 TEST HOLE OF M.O.A. APPROVED SAND FILTER AND THAN 0.5 FEET OF PEA GRAVEL (SEE PACE 2 OF 2 FOR CONSTRUCTION DETAIL AND REQUIREMENTS) ISTINC DRAINFIELDS TO BE USED AS A RESERVE STIL (EARE XACT LOCATIONS T00 W UNKNOWN) 10' UTIL ESMT. / \ j AIR / v (SEE STEVEN R. PANNONE. P.E. 6/14/2002 TEST HOLE - EXISTING TANK TO BE I AND REPLACED WITH 1250 GALLON SEPTIC INSTALL FOUNDATION NOTE: THE CONTRACTOR MUST HAVE THE NORTH AND SOUTHWEST PROPERTY LINES FLAGGED BY A REGISTERED LAND SURVEYOR PRIOR TO CONSTRUCTION. THE AIR COWRESS13R SHALL BE LOCATED VITHIN THE BASEMENT OR THE GARAGE, THE CONTRACTOR SHALL PROVIDE A 0-10 PSI PRESSURE GAUGE AT A LOCATION WHICH IS READILY ACCESSIBLE FROM WITHIN THE HOUSE, NOTE, A 30 PSI GAUGE VILL NOT WORK. THE AIR COMPRESSOR SHALL BE A THOMAS INDUSTIES MODEL 5070, AS SUPPLIED BY ANCHORAGE TANK. THE AIR LINE SHALL BE 1/2 INCH DIA. HDPE u PIECE), 'INSULATED WITH 1/2 INCH FOAM PIPE WRAP 023 VALUE). INSIDE A 2 INCH SCK40 PVC JACKET. THE LINE SMALL BE BURIED TO A MINIMUM DEPTH OF 3 FEET. THE CONTROL PANEL FOR THE STEP TANK SHALL BE INSTALLED WITH A AUDIBLE/VISUAL INDICAT62 WITHIN THE BASEMENT OR GARAGE. 550 GALLON G� �Q�� : "• INSTALL AIR COMPRESSOR INSIDE FOUNDATI N •• (SEE NOTE) ., . Q G oAtOR8VISED `oo�Opp / �d O .0 DRAWN DRWN B: a�.. S . _ -11r�..__e� �J.L.M. 4 �QOO ALASKA «'ATER & «'ASSCALE: 4 I �------------CONSULTANTS,INC .�-- 1�. — 30. """' ... „• :.,,•Q 6901 DEBARK ROOD. SUITE 29 • ANCHORAGE. AK 99504 • PHONE (907)337-0179 • FAX (907)338-3246 PREPARED FOR: PHONE NUMBER: PACE NUMBER: JERRY LEWIS(907) 250-9958 1 OF 2 r y G e s LEGAL DESCRIPTION: O 7953 LOT 1. BLOCK 1; SPRING BROOK VISTA SUBDIVISION # y1 �° TYPE OF WORK: 0°O'Profa3slol REVISED DESIGN FOE SEPTIC SYSTEM UPGRADE ��Opppoo R LINE COIL SPACED AT 'ROX. 1.5 FEET. ORENCO STEFLOW TYPE PROVIDE( BY ANCHORAGE TANK.—�, 6' LAYER OF 2 FEET MIN. OF APPROVED SAND —12 ' x 30' BOTTOMLESS ISF. NO LINER ON BOTTOM. PRESSURE 3/4DIA. SCH. 40 PVC LITERALS PIPING DESIGNED BY ORENCO AND (HOLES, SHIELDS. AND FLUSHING SUPPLIED BY ANCHOARGE TANK VALVES PER ORENCO DESIGN) ---- ------------------ --------� i I I I iv I I I I 4' DIA. MONITORING TUBE AT EACH END. PERFORATED BETWEEN TOP OF SAND AND DISTRIBUTION PIPE INVERT. (DRILL 1/4' DIA HOLES) 3/4' PVC LATERALS Mf PEA GRAVEL ,ALS BURIED STRATUM. �E t' PLAN VIEW FINAL GRADE 1 Mf INSULATION InLTER FABRIC -7 2' MIN. OF CMI; AIR 1110 BELOW / TOP OFESAND FILTER) PROFILE VIEW DATE. � I10/8/200 t L DRAWN BY: ALASKA. `VATI✓R & WAS TENNIATIJSCALL* SCALJ.L.M. CONSULTANTS, INC. N.T.S. 6901 DESARR ROAD. SUITE 28 • ANCHORAGE. AK 99504 • PHONE (907)337.6179 • FAX (907)338-3246 REPAIRED FOR: PHONE NUMBER: PACE NUMBER: JERRY LEWIS (907) 250-9958 2 OF 2 LOT 1, BLOCK 1; SPRING BROOK VISTA SUBDIVISION #1 OF WORK: DETAIL OF BOTTOMLESS INTERMITTENT SANE FILTER (ISF) TUBE (TYP.) GRADE . eff. ..... :... Q�,0 s 7953 4�0�- ofesslotlo �� P4 OF op ALASKA. WATER & WASTEWATER CONSULTANTS, INC. g .. 6901 bEa4RR ROAD. SUffE 28 • ANCHOW L50 •(907)337-4119 • FAX. (907)338-3248 • • a c M SOIL LOG - PERCOLATION TEST . .......... LEGAL DESCRIPTION: LOT 1 BLOCK 1' SPRING BROOK VISTA SUBDIVISION #1 Q e 'J Y- 953 ess• oL PERFORMED FOR: JERRY LEWIS DATE: 10/7/2002 �p04'e c��oa ��ocy o e4P (feet) ORGANICS TEST HOLE 1 ssloa ��o��� 1. 41-0 2 3 4 5 6-11 LI M111 GM/SM 7 8 9 10 11 12 13 14 15 16 17 18 •im • NET TIME (MINUTES) WATER LEVEL READING NET DROP (INCHES) 10/8 2002 1 •� - • ' - 111111111 2:00 Ilrlll!11 5-1/4- 4'3 3/4- �//moi 00:00 - 6' - MUIR 00:00 30 5-1/4- 3/4' 5 IIIIIIIII - 6' - 6 00:00 //% 5-1/4- 3!1!1111 Q'.�.� • DEPTH TO DATE GROUNDWATER 9' 10/7/2002 SEE DESIGN DRAWING DATE READING CLOCK TIME NET TIME (MINUTES) WATER LEVEL READING NET DROP (INCHES) 10/8 2002 1 1:30 - 6' - 2 2:00 30 5-1/4- 4'3 3/4- 3 00:00 - 6' - 4 00:00 30 5-1/4- 3/4' 5 00:00 - 6' - 6 00:00 30 5-1/4- 3/4' PERCOLATION RATE 40 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) 19 TEST RUN BETWEEN 3.5 FT. AND 4.0 FT. 20 A FOUR HOUR PRESOAK WAS PERFORMED: 0 YES ❑ NO SOILS LOGGED BY: JODY MAUS PERCOLATION TEST PERFORMED BY: ZACH GALL COMMENTS: GROUNDWATER IN STEVE PANNONE'S TEST HOLE WAS AT 8 FEET ON 10/7/2002. PERFORMED BY AKWWC, INC. I, JEFFREY A. GARNESS, CERTIFY THAT THIS W S VERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: to 03- FROM : 0 & J Hall/Eagle River, Alaska PHONE N0. : 907 694 6324 W= EM - UMCG I.RM059 PANNONE ENGINEERING SERVICES P.O. BOX 102954 ANCHORAGE, AK 99510 (907) 272-8218 PERWRMED FOP- Jerry I envie DATE PERFORMED: 6-14-02 LEGAL DESCRIPTION: l•ot 1, Black 1 Spdngbrook V1ota S/D TWTHOIS 1 ownL— OR TOPMOR 1 YL 2 --fHwwn 84t 3 am/ P*0dy aadad OP to aV at. 4 s 6 7 6 9 10 11 12 18 14 16 16 17 18 19 20 ou /a�ttiae 80t Sep. 18 2002 10:06PM P10 49IL ti••f ........................ • :Steven R. Pannone /!n.._No.CE 8149 : i ` , WAS GROUND WATER ENOOUN MM? No W YES, AT WHAT DEPTH? -0- DEPTH TO WATER AFTER MONIrORING? -0- 5ATE: 7-4-M "Z0 oti 1o�a'oz pEROLATION RATE 30 f nin/inch) PERC HOLE DUUUMM 0 mrm. TEST RUN BEVrEEN 4 FT and 5 FT COMME M: Teat hole e=ayated by Owner. Teat Hole Waa RM2Ske4before pert t t- . nrw%ntswn uv. s:..o... it_ Pnnnnme_ P -E. I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE �wMrM � ® wow���� pEROLATION RATE 30 f nin/inch) PERC HOLE DUUUMM 0 mrm. TEST RUN BEVrEEN 4 FT and 5 FT COMME M: Teat hole e=ayated by Owner. Teat Hole Waa RM2Ske4before pert t t- . nrw%ntswn uv. s:..o... it_ Pnnnnme_ P -E. I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE W OF ♦� DROP PANNONE ENGINEERING SERVICES �` AF -t •°'}��� 19.36 P.O. BOX 102954 49TM �.....•.....................................� 6• ANCHORAGE, AK 99510 i 0 272-8218 .... ......................... . (90� �� ;Steven R. Pannone- i 30 �� ` AV No. CE 8149'AV AV PERFORMED FOR Jerry Lewis DATE PERFORMED: 6-14-02 1\&' 4.0 2006 88aa�wsi'&W LEGAL DESCRIPTION: Lat 1 ck Blo1 Spain&mok Vista S/D TEST HOLE I orpmk �PC SrM PLAN OR Topeoll 30 S 1/8' ML Brown sm1 2 ---- 3— am/ Poody graded OP to Only 0m els 10. 4 T ' 1 1/4• TEST H IE 10 S 7 0m 2 8 OPravew ww//trsoe 9 Bit< 10 11 BOH V� 12 13 WAS GROUND WATER slays 14 ENCOUNTERED? No 15 IF YES, AT WHAT DEPTH? -0- TEOT HOLE 16 DEPTH TO WATER AFTER 17 MONITORING? -a- 18 DATE: 7-4-02 19 araDala DAa GROW 2W n�nt or lar TM 7= 90 1-1 PEROLATION RATE 30(min/inch) PERC HOLE DIAMETER 6 inches TEST RUN BEWIEEN 4 FT and 5 FT COMMENf3: Test hole aooavated by Owner. Test Hole was presoaked before pert test. PERFORMED By. Steven R. Pannone P.E. I CERTIFY THAT THISST TEWAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUM12M IN EFFECT ON THE DATE OF THIS TEST. WA7>at DROP 6-1�-02 19.36 6• ---- 20�06 30 5 3/4' t t/1' 2006 ---- 6 3/8' ---- 20.36 30 S 1/8' 1 1/4• 2036 ---- 6 1/1• ---- 21�06 30 5' 1 1/4• M W �J \VV// �0Q M z3 W CL 259 ZW 4. H W m W X W t7 X t7 O W z O N Z= K • ll.! ..l v 4 0. v v > N N oe QW 2 n pV' J 4 a V I.r .= V O lV F- N 6 p..\ {j J Ca Ln W \ \ Z J \C3 CY ZO :ELa CD J W �•o �Lj r. W I t! F \ J �OOC) W\ O I C7 Q la. d 3.O W— LJ S ► E W � Ul 04 W ► ► dd �ry,7n,1 cn ► ► ► I I O 1 ( = ^ U —► W LAJ �x • o� a VJ � ) 11_t� T W ► � •Z - Nom W Li Z m W N � N cr 1 o a I! �f Ld L IDSF KIT FOR BOTTOMLESS FILTER CONSIST OF THE FOLLOWING COMPONENTS -r T\ae_ 6S-0 GfCtLd 1. Pump basin asembly - 3 a) PVC Cylindrical valt filter and pump assembly b) Effluent filters 1/8", 1/4". 3/8" c) Goulds turbine model 20EB05 or equal pump d) Float tree (alarm, on, off, reduntant off) e) 1,1/4" Flex Discharge assembly f) Splice box (SBJ 1104) 2. Control panel TC115HC Elapsed time meter, -'cycle counter programmable cycle timer NEMA 4x rated UL 508A 3. Filter Fabric Breathable fabric to protect top of sand 4. Air Coil Manifactured by GEOFLOW; WF16-4-24 150 LF to allow air to be injected into sand 6" above bottom. 5. Air compressor Thomas Linear Series model 5060-A air guage 0-10 PSI and 50 LF 5/8" hose. For remote installation. 6. Sand Filter Manifold Assembly ; a) 6" x 30" PVCflushing lushing valve access pipes with 6" PVC caps. (9) for 18' x 20' filter or (5) for 1200 filter or (4) for 1006 filter. b) Flushing valves 3/4" DIA, same number as a) above. C) 314" DIA. PVC SCH 40 pipe, predrilled with 118" DIA. orifices on 2'C -C. (length and number or pipes will vary dependent on filter size) d) Orifice Shileds Number will vary dependent on filter size. e) Manifold with fittings 1114" DIA SCH 40 31 is 32 WW4:19 RUSH ALASKA WATER & WASTEWATER ..aw • CONSULTANTS, INC. October 1, 2002 F(2;vl5Iotj or Municipality of Anchorage Development Service Department Building Safety Division On -Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650 Anchorage, Alaska 99519-6650 �w0-2, NO (Ltcc,p4 -4= 2 4 3 G 1 W VI0O-10075 0 Ref: Revisions to Septic System Design for Lot 1, Block 1; Spring Brook Vista S/D To whom it may concern: A septic upgrade permit (permit# SW020238) was issued on July 22, 2002, for an Advantex treatment system. The Advantex design was prepared by Steve Pannone, P.E. The homeowner contacted AKWWC, INC. requesting that we design a conventional septic system for the property. Per the owner, the house is currently a three bedroom residence; but would like to install a 4 bedroom septic system. The existing drainfields are sized for a 4 bedroom residence so an alternate site will not needed to be provided. Comments regarding the re -design of the septic system are as follows: 1. SOILS: A test hole was recently excavated on the property by Steve R. Pannone, P.E. According to the percolation data, the rate was 24 minutes/inch, which equates to a 0.6 application rate. Also, a test hole was excavated on the property by Robert A. Shafer, P.E. in 1983. According to the soils log, the percolation rate was 60 minutes/inch, which equates to a 0.45 application rate. We are proposing that a 0.5 gallons/day/112 be used and that a confirmation test hole with a percolation test/s be performed prior to the installation to confirm this application rate. The monitoring tube for Pannone's test hole has been checked and found water to be at 11 feet below the ground surface. 2. TRENCH DESIGN: a. Percolation Rate: 24 & 60 minutes/inch b. Allowable Application Rate: 0.5 gallons/day/ft2 c. Number of Bedrooms: 4 d. Design Flow: 600 gallons per day e. Minimum Absorption Area: 1200 ft2 f. Total Depth: 6.5 feet (max.) 6901 Debarr Road, Suite 2B • Anchorage, AK 99504 Ph: (907) 337-6179' Fax: (907) 338-3246 • Website: akwwc.com g. Effective Depth: 4 feet h. Width: 5 feet i. Reduction Factor: 0.50 j. Minimum Length: 120 feet total length (1 @ 75 feet long and 1 @ 45 feet long) k Effective absorption area = 1200 R2 3. SURFACE WATERS: There are no surface waters within 100 feet of the proposed design. 4. TOPOGRAPHY: The area for the proposed septic upgrade is a 1 to 5 percent slope running from south to north; in short, there are no slope concerns. 5. LOT LINE \VAIVER REQUEST: We request that a 1 foot lot line waiver be granted from the southwest lot line to the proposed drainfields. We are unaware of any adverse effects that this installations would have on the adjacent property. We are unaware of any adverse impacts this installation would have on adjacent wells or septic systems. If you have any questions, please contact us at 337-6179. Thank you for your M.S. NOTE: Attached is a revised design drawing, a profile drawing, two soil logs, and a 7 page construction specification letter which are all part of the design package for this septic system. 6901 Debarr Road, Suite 2B' Anchorage, AK 99504 Ph: (907) 337-6179 • Fax: (907) 338-3246 • Website: akwwe.com CONFIRMATION TEST HOLE AND PERCOLATION TEST TO BE PERFORMED PRIOR TO ANY EXCAVATION PROPOSED DRAINFlELDS. EXCAVATED TWO ROBERT A SHAFER, P.E. TRENCHES THAT ARE 6.5 FEET DEEP MAX. 7/19/1983 TEST HOLE BY 5 FEET WIDE. THE LOWER TRENCH IS 75 FEET LONG AND THE UPPER TRENCH 1�{STALL FLOW SPLfTTERS IS TO BE 45 FEET LONG. ADD 4 FEET (SEE DETAIL DRAWING) OF CLEAN. WASHED SEWER DRAINROCK. ISTiNC DRAINFlELDS TO BE (SEE DETAIL DRAWING, PAGE 2 OF 2) USED AS A RESERVE SITE. (EXACT LOCATIONS ARE UNKNOWN) 10' UTIL ESMT. -------- f.---1— At --- STEVEN R. PANNONE. P.E. 6/14/2002 TEST HOLE— EXISTING TANK TO BE REMOVED AND REPLACED WITH A NEW 1250 GALLON SEPTIC TANK INSTALL FOUNDATION CLEANOUT— NOTE: THE CONTRACTOR MM HAVE THE NORTH AND SOUTHWEST PROPERTY LINES FLAGGED BY A REGISTERED LAND SURVEYOR PRIOR TO CONSTRUCTION. TO 75TRENCH — 0.83 TO 45' TRENCH �— INSTALL FLOW DNERTER INSTALL DOUBLE A- CLEANOUTS wi ,.; •. L r 1 / . O e4l / Q •t—FROM TANK �;. 9/25/2002 OF - .... _ ... ._ _ �� Y�.__ .._•.:�-- - - --- - ...__._..-.._. _. DRAWN BY: vo'` ••••... .... ALASKA WATER & `VASTENVATER J.L.M. -� CONSULTANTS, 4 INC. S CAL E * 901 DEBARR ROAD, SUITE 28 • ANCHORAGE. AK 9950L • PHONE (007)337b170 •FOX (907),558.32L6 1••=30• �.......... PARED FOR: PHONE NUMBER: PAGE NUMBER: 0 JERRY LEWIS (907) 250-9958 1 1 OF 2 Je f e s :AL DESCRIPTION: A 9 0.4 `� LOT 1, BLOCK 1; SPRING BROOK VISTA SUBDIVISION #1 f,^ oAo ev E OF WORK: °feset°^ REVISED DESIGN FOE SEPTIC SYSTEM UPGRADE Oppn��000� 75 FEET LAN I oI T L --------------------------------------- --------i INSTALL FLOW SPLITTER TI' OMT ---------------------- MTO J4 --FROM SEPTIC TANK I I I o co—[ 5 FEET LON E' WIDE 10' WIDE 9/25/2002 ''ALAJ.L.M. p:k SKA «'ATRR & «TASTRN'VATKR 4CONSULTANTS, INC.te`901 DEBaRR ROpD. SUITE 28 • pNCMORpGE. pK 9050E • PMONE (907)337.6179 • FpX (907)338-32L6S...... ........ ...... .PARED FOR: PHONE NUMBER: PACE NUMBER: JERRY LEWIS (907) 250-9958 2 OF 2 Q •. of re . Gorn s. ;AL DESCRIPTION: OQ — 953 LOT 1, BLOCK 1; SPRING BROOK VISTA SUBDIVISION #1 4p 'E OF WORK: 4v0wcfpr°(aaslo°°��oo DETAIL DRAWING OF PROPOSED DRAINFIELDS O4pppp000� MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water& Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Upgrade Permit Number: SW020238 Legal Description: SPRING BROOK VISTA #1 BLK 1 LT 1 Design Engineer: 0062 Pannone Engineering Services Owner Name: Jerry Lewis Owner Address: PO Box 19063 Anchorage , AK 99519-0000 Date Issued: Jul 22, 2002 Expiration Date: Jul 22, 2003 Parcel ID: 050-091-28 Site Address: 012336 PRINCE OF PEACE DR E Lot Size: 16241 SO. FT. Total Bedrooms: 4 Permit Bedrooms: 4 This permit is for the construction of: ❑✓ Disposal Field 0 Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction must be in accordance with: The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations (18AAC80 ). 3, The engineer must notify DSD at least 2 hours prior to each Inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: Issued By: Date: 2 7� -Au'Cer �' Date: 2 ka Pannone Engineering Services, LLC P.O. Box 102954 Consulting Engineers Anchorage, Alaska, 99510 (907) 272-8218 (907) 272-8218 Fax July 7, 2002 Municipality of Anchorage Development Services Department On -Site Water & Wastewater Program 4700 S. Bragaw Street P. O. Box 196650 Anchorage, Alaska 99519 Subject: Lot 1, Block 1 Spring Brook Vista S/D Septic System Replacement Permit Request Failed Septic System Gentlemen: My firm was contacted to a Health Authority Approval of the septic system serving this lot. The existing trench was inundated with liquid when I arrived. The system is in failure. A single test hole was excavated on June 14, 2002 on the lot. The soils report and a percolation test result is attached. Ground water was monitored for seven days. No bedrock or ground water was encountered in the test hole. however, past experience has shown that ground water is present in this subdivision at a depth of approximately seven feet. This will be used for the ground water design depth. An Advantex AX20 Septic System will be installed as the upgrade system. The lot is approximately 9,200 square feet in size. Lot 1 slopes to the northwest at approximately 1-2 percent in the area of the test holes. The ground around the test hole slopes at approximately 10 percent south and west of the test hole. The existing septic tank will be abandoned. The proposed installation will be located on the northern portion of the lot. The lot is served by a community well (AWWU). The proposed location is greater than 200 feet away from existing & neighboring wells and 25 feet from the water service lines. The surrounding wells are located greater than 200 feet from the proposed installation. The proposed installation will not affect the future development of the surrounding or existing lots. See the attached design. If you have any questions or concerns, please contact me at 227-3522 or 272-8218. Sincerely, .•,..• OF ��♦♦ �•`P�E„ �. Steven R. Pannone, P.E. :' 49TH i Civil Engineer i-•••-�- Attachments: 's��� : �evcn R. Pannone//I Nn. C[ 8149 �. 4111 Q\Work\Letters\1-1Springbrook Vista.001.doc PERMIT NO, DESIGN WASTEWATER DISP❑SAL SYSTEM LOT 1 BLOCK 1 SPRING BROOK VISTA S/D NO WEL( WITH 2001 S OF PROPOSED SYS EM. NO SE TIC ON THESE LOTS - SE VED BY AWWU SE ER -7 &WA ER / PROPOSED PRIMARI FIELD 40LFx5'xO.5'1 3' TD --------------►------v-------,i-------- 10 PROPOSED ESERVE FIELD 40L 5'x0,5', 3' TD-/ EXIST'�000g SEPTI TANK 3 0 BE REMOVED P.I.D. NO, 050-091-28 INFIELD IN FAILURE. ___ _ ABANDON IIN PL P POSED ADVANTEX SEPTIC SYSTE W/AX20 POD NO WELLS WITH 0' NO OF PROPOSED SYS ALLWORK SHA BE IN ACCORDAN WITH 2) MATERI USED Si ACCORD E WITH THE IN 15.65, WASTE XIST'G 4 BR. USE \\\DRAWING\32-4VatlVue.D CONNECT POST ANK LptE TO MID- (P ❑INT OF DRA FIELD.iT%P AL. 4) MAINTAIN 0' SEPARATION O ALL �4LOT • (E ,••• LINES. 5) LOT SERVED BY CLASS WATER SERVICE. •��� ••••♦♦♦ �P • 1♦ ' �'J;°• NO WELLS WITH IN 200' OF PROPOSED r ♦ SYSTEM. ix :° TM :, �?♦♦♦ 6) INSTALL ADVANTEX SYSTEM PER MFG — .................. , & MOA INSTRUCTIONS & INSTRUCTIONS. Ll PREPARED FOR, •....................PANN❑NE ENG. SVC, LLC jAlkSteven R. Pannone: 1 Jerr Lewis • v P. ❑. BOX 102954 0 : . No. CE 8149� P.O. Box 190963 ♦♦ •♦1 ANCHORAGE, ALASKA 99510 AK 99519 'cp�t •�� •�� 250-9958e, ♦♦4�,,;'����� 227-3522 P, 272-8218 Fax DATEt 6-;_02 DESIGN PERMIT NO, DESIGN DETAILS P.I.D. NO, 050-091-28 WASTEWATER ABSORPTION SYSTEM LOT 1 BLOCK 1 SPRING BROOK VISTA S/D NOTE, 1) ALLWORK SHALL BE PERFORMED IN ACCORDANCE WITH AMC15.65. 2) MATERIALS USED SHALL BE IN ACCORDANCE WITH THOSE SPECIFIED IN AMC15.65, WASTEWATER DISPOSAL. 3) CONNECT POST TANK LINE TO MID- POINT OF DRAIN FIELD. TYPICAL. 4) INSTALL DRIVEWAY AT LEAST 5 FT AWAY FROM DRAINFIELD. DO NOT INSTALL DRIVEWAY OVER DRAINFIELD. 5) MAINTAIN 10' SEPARATION TO ALL LOT LINES. v a a u c L d y Q L U A m L d Z Drawing C,\Work\1-1SPRINGBROOKVISTA.DWG 1nD NV313 3en1 aDitND !no NV31 lno NV313 lno NV313 lnD NV313 lno NV313 C.? 1� NDuvaNnei :4Y... ........0..... 1PREPARED FOR: en R. annone: Jerry Lewis CE 8149 P.O. Box 190963 �--��.,� �• Anchorage, AK 99519 7v.�.s1, _•• 250-9958 W J LL_ 0 C� Pannone Eng. Svc., LLC P. ❑. BOX 102954 ANCHORAGE, ALASKA 99510 272-8218 PHONE & FAX 4TE, 6-1-02 1DESIGN 'OT To SCALE PERMIT NO, SW DESIGN DETAILS P.I.D. NO, 050-091-28 WASTEWATER ABSORPTION SYSTEM LOT 1 BLOCK 1 SPRING BROOK VISTA S/D 3• INSTALL 4' RIGID INSULATION OVER TANK & DRAINFIELD. EXTEND R.I 2' BEYOND SIDE OF TANK. INSTALL R.I. AROUND AX -20 FILTER. ADVANTEX TANK DETAIL DESIGN CALCULATI❑NS Number of Bedrooms - 4 Total Bedrooms - 4 Design flow - 150 gal/br/day, Total flow - 600 9/day MnrawLE TANK SIZE+ 1500 gallon Advantex tank SOIL ABSORPTI❑N SIZE, Advantex Sewer System AX20 Pod - Class III System Perc Rate= 30-60 min/inch Application Rate= 3 GPD/SF Size Required= 600 GPD/3 GPD/SF = 200 SF .•g'`,o.•..... -'�j Use 5 -Wide Trench, 0.5' effective :>}�� 40 if Req'd _ 4,9� ; Single Trench, 40 lf. ..................•- rKLrAKtli r UKl PANN❑NE ENG. SVC. ren R. Pannone: Jerry Lewis P. ❑. BOX 102954 No. CE 8149 P.C. Box 190963 ..............,.•� Anchorage, AK 99519 ANCHORAGE, ALASKA 99510 250-9958 272-8218 PHONE & FAX �VI�"`���� NOT�ATE6-1-125 LEI DESIGN Pannone Engineering Services, LLC P.O. Box 102954 Consulting Engineers Anchorage, Alaska, 99510 (9071272-8218 (9071272-8218 Fax RECERCULATING SEPTIC TANK AND TRICKLE FILTER SPECIFICATIONS Lot 1, Block 1 Spring Brook Vista Subdivision 1. GENERAL STATEMENT OF WORK 1.1 The work and plans covered by these specifications consist of furnishing all labor, materials, tools, transportation, and equipment necessary to complete an recalculating septic tank with trickle filter system as described herein and on the attached Contract Drawing. All work under this project shall comply with current Municipality of Anchorage (MOA) Regulations and shall conform to the following: • Four (4) Bedroom Private House 1.2 The Contractor shall carefully examine the project documents, have full knowledge thereof, have investigated the site and be satisfied with all conditions affecting the work. The Contractor shall notify the Engineer IMEDIATELY if conditions are encountered during the site investigations that affect the work. Any failure of the Contractor to become acquainted with the available information will not relieve the Contractor from the responsibility of performing the work as stated in these specifications. 1.3 The Contractor shall call for locates of utilities. Damage to utilities by the Contractor if locates are not called for is the responsibility of the Contractor. 2. MATERIAL 2_1 Tank: Septic: Tank shall be a two (2) compartment tank of at least the minimum size indicated on the drawings and shall be MOA approved. The compartments shall have a separate 4" clean-out riser. 2_2 Manhole Riser or Lift Station Tank: An additional second compartment manhole riser shall be capable of being equipped with the following: a. A junction box (Nems 4x) or equal, bonded or attached to the pump basin. b. UL listed electrical cord grips, installed in the J -box. C. An additional tank (MOA Approved) may be provided for the effluent pumping assembly and the items above. 2_3 Effluent Pumping Assembly, Controls, Alarm & Piping: a. Effluent pumping assembly shall be of approved materials, including: A 110 volt or equal UL listed effluent pump; High-density PVC cylinder housing the pump, with level controls and screen, serving as a baffle to prevent the screen from clogging; All piping shall be PVC or other non corroding material approved by the MOA. Pannone Engineering Services, LLC P.O. Box 102954 Consulting Engineers Anchorage, Alaska, 99510 ( 907) 272-8218 (907) 272-8218 Fax b. Pump controls and alarm system shall be an approved system with the following options: - Event Counter - Elapsed Time Meter - Program Timer - 10 Watt Heater - Remote alarm panel option with a minimum of 80 dB sound pressure at 24 inches, operating temperature 30 AC to 65 AC, and continuous sound to be located in the house. - Oil tight visual alarm with push -to -silence feature. Automatic audio alarm reset. - 15 amp motor rated toggle switch, double pole, double throw with three positions; Manual (man), Automatic (auto), and off. - Nema 4x rated fiberglass enclosure with hinged cover, or equal. - All controls to be installed per manufactures instructions. - Control panel to be installed on outside wall of home within sight of septic/lift station. c. Piping from septic tank to the trickle filter is to be 1 '/4" PVC schedule 40 solvent weld piping properly bedded and sloped to drain back to the lift station. Insulation board shall be placed over the line where the cover is less than four feet. d. The Air Compressor shall be a Thomas Linear Series model No. 5060-A or 507OV-A or MOA Approved equal. 2.4 Trickle Filter a. Trickle Filter Pod shall be AX20 manufactured by Orenco Systems Inc. and distributed by Anchorage Tank & Welding. b. Install all materials according to manufacturers instructions and in accordance with MOA regulations. 2.5 Soil Absorption System a) The drain field shall be constructed as shown on the drawings and in accordance with all applicable regulations described in Municipality of Anchorage AMC Title 15.65, "Wastewater Disposal Regulations" (MOA). b) Gravel to be used in the soil absorption system shall be well graded rocks and cobbles with size ranging from '/Z" to 2 '/z" and approved for use in soil absorption systems by MOA. c) Perforated pipes shall be F810 LDPE or PVC 3034pipe, with two rows of perforations and shall be approved for use in soil absorption systems by MOA. d) Clean-out pipes and monitor tubes shall be 3034 PVC solid pipe. e) Clean-out caps shall be rubber "Jim Caps" securable with adjustable metal bands. Friction fit caps will not be accepted. Pannone Engineering Services, LLC P.O. Box 102954 Consulting Engineers Anchorage, Alaska, 99510 (907) 272-8218 (907) 272-8218 Fax PART 3 EXECUTION 3.1 LOCATION AND GRADE a) The septic tank shall be placed at the locations and elevations as shown on the Drawings. b) The drain field shall be placed in the location shown on the Drawing, with minor adjustments allowed to minimize excavation and accommodate the existing terrain. The drain field piping shall remain level over the length of the drain field. c) Dewatering may be required for all excavations that penetrate the groundwater surface. Dewatering costs shall be incidental to the excavation. If ground water is encountered during the excavation for the septic system, notify the engineer immediately. 3.2 EXCAVATION a) General: The Contractor shall accomplish all excavation required by the drawings through whatever substances encountered, to the depth as shown on the plans. All excavation shall be accomplished in accordance with the State of Alaska safety code and other applicable safety requirements. b) Water Removal: Water is expected in the limits of excavation as evidenced by the soil test pit information. If an apparent water table is observed in any of the excavations less than 5 feet below existing grade, notify the engineer immediately. 3.3 INSTALLATION A. Septic Tank 1. After excavation the tank shall be placed on undisturbed soil on a level grade at a depth as indicated on Drawings. Backfill around the tank with structural fill. Fill shall be installed in 12 inch lifts, compacted to 95% maximum density. Any damage to the protective coating during installation shall be repaired as recommended by the manufacturer. 2. The tank inlet shall be set at the elevation shown on the drawings. Care shall be taken during installation to ensure the proper elevation drop between the inlet and the outlet. Install flexible "furnco" rubber fittings at connection from tank to inlet and outlet pipes as indicated on Drawings. B. Joining Pipe Sections 1. Pipes shall be joined to one another, to the polyethylene fittings, cleanouts, and electrofusion couplings. Pannone Engineering Services, LLC P.O. Box 102954 Consulting Engineers Anchorage, Alaska, 99510 (907) 272-8218 (907) 272-8218 Fax 2. Cleanouts: (1) All earthwork and fill necessary to install the cleanouts shall be considered incidental. 3. Jointing: a. Fit the heat channel in place, ensuring that ends are deburred and square to allow easy passage of electrocal or glycol heat trace. b. Fit the insulation half -shells snugly in place. Band with strapping to hold tightly in place. c. Heat Shrink Coupling: Cover entire exposed joint plus an overlap of four inches on pipe coated on either end. Heat in accordance with manufacturer's instructions. 4. Installation: a. Install insulation half -shells and heat -shrink wrap at pipe connections. Maximum gap in half -shells shall be '/4 inch. b. Lower assembled insulated pipe carefully into trench. Do not allow joints to deflect greater than the elastic capacity of the heat shrink sleeves. If sleeves are found to be damaged, reduce the deflection and repair the damages sleeves. c. Tolerances: (1) Lay mains to indicated line and grade. Perform earthwork in accordance with the Drawings. (2) Minor Changes in Direction: Pipe deflection will be allowed for small changes in direction, provided that the pipe bending radius is less than 30 times the diameter of the outer jacket of the insulated pipe system. C. Drain Field a) The drain field area shall be excavated to the elevation and dimensions as shown on Drawing. Remove all organic and silt material to the top of the well -graded sand layer. After excavation, the open bed shall be protected from surface runoff to prevent the entrance of silt and debris. Under no circumstances shall the use of heavy equipment be permitted on the drain field surface. All smeared or compacted surfaces shall be raked to a depth of 1 inch, and loose material removed, before any of the drain rock is placed. b) After all organic and silt material is removed, sand bedding shall be placed to an elevation shown on the drawings. Sand shall not be compacted. c) The bottom of the bed should be as level as practical. d) The gravel -less system and distribution piping shall be installed as shown on the drawings. e) The drain field shall then be backfilled with sand bedding to a depth of 1.0 above gravel -less system. Filter fabric and insulation shall be placed over the sand bedding. Pannone Engineering Services, LLC P.O. Box 102954 Consulting Engineers Anchorage, Alaska, 99510 (907) 272-8218 (907) 272-8218 Fax Backfill above insulation with material excavated from the building -pad to the elevation shown. The material shall be mounded over the drain field as shown on Drawings. Backfill of drain field shall not be compacted. D. Close -Out A. Contractor shall submit unqualified as -built drawings and certificates on MOA approved forms to the Engineer, and MOA for approval to Operate. October 4, 2002 Municipality of Anchorage Development Service Department Building Safety Division On -Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650 Anchorage, Alaska 99519-6650 To whom it may concern: The following personal information/resume shows experience and qualification for owner - installed septic system in the Municipality of Anchorage for recently issued permit at 12336 E. Prince of Peace Drive, Eagle River, Alaska 99577. I have been a resident of Alaska since 1962, and worked for 25 years in the excavating and trucking business (projects from road building to septic systems) with several area - wide contractors, to include the following: Wedekind Excavating Cooper Excavating Conway Excavating & Trucking Gilman's Excavating & Trucking Wilder Construction H & H Trucking McCleod Trucking I retired as a Teamster in 1982 from Seal -and Freight Service. P.O.Box 190963 Anchorage, Alaska 99519 (907) 250-9958 MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION 0 ENVIRONMENTAL ENGINEERING DIVISION 825 L Street - Anchorage, Alaska 99501 Telephone 264.4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT NAME PHONE ❑NEW utrh LC' CC.t G.'` PGRADE MAI LI NG ADDRESS C '� , , pea « ^�� C- /� ,(7 Vet 77 LEGAL DESCRIPTION �,� L_( [?) l ':5 �yl✓� UL`s (0. LOCATION NO. OF BEDROOMS Well Absorption area Dwelling PERMIT NO. DISTANCE TO: Uy No. of compartments o. Manufacturer ... Material QUj w ~ Lin. capacity in gallonsIF HOMEMAE: - n e eng Width Liquid depth 00�' DISTANCE TO: Well Dwelling PERMIT NO. - O? Q Manufa� er Material capacity in gallons' x O _J; DISTANCE TO: Well Foundation : lcC) Nearest lot line 4- 1 o,? PERMIT NO. _ •3-) i s �-- w Lu Lu M No. of lines Length of each line - a Total length of Ines Trench width (F inches Dist�n a between lines /%3 ;6 z w ~ Q Z._ �- Top of tile to finish grade - ,; Material beneat the r �� spas Totalreffective absp t area �' 6+- ,.e_. L� SwLIi)" Length V&dth Depth PERMIT NO. w Q k- Type of crib Crib diameter Crib depth Total effective absorption area Lu w N Well Building foundation Nearest lot line DISTANCE TO: Class Depth Driller Distance to lot line PERMIT NO. J w Building foundation Sewer line Septic tank Absorption area(s) DISTANCE TO: OTHER PIPE MATERIALS /' SOI L TEST RATIN�ot 1�17 b aut Acr= INSTALLER -- RENrARKS p APPROVED? � DATE p LEGAL O 1(] S. `. (IrJ 72-013 Wv, 3/78) I/ I RI-IFINEI'A FiF'.01 EC f L i.aY.i/05,43 0 P. , t I A., t IE 9 2 I ow Pi- I C A 14 "1" J, ': P F.'.'f PICE�' OF PIE.TICE 4 - 5 eI J. 6 t.. C"C'FIT 101'.1 E,�:. R_ I E G1=11.... 1 iEd. 15,PRII,-JG BROCH,:: L-C)T '999999 SG!UFIr,':E F-EET TYPE OF ",CQ[ OPA PURIXIVUH tAIJI-IBET" C)F -g, RFITING C.SC! Bk: 4 W.5 Tva? REQUIREE) SWE OF THE :.H. -:01I... IS: /7/ E--,.". Y IH 7" 11-18c Q0=1 Iwo M U ED; EDWW-11-H.-O Os IL THE I F.-.1'AG"FI-I 'FLIFE L.EbMTH (H -A FEFET) OF -I FIE "FREhICH C,RFMIFIELE). "FFIE". Df.,.­F,TH OF" i-1 1S; THE BETNIEEI,A 1"FIEE -'.;URF:T)C:E OF THHE GF THF: BC,11­1*01-1 OF' TFIF:_. (IN F'EET'.). 0 11-1. IF"T. 1 P.-.11 cl.,: g...1 11. 1 -.0. -If" H......0 ].R: :SE5., F=" FEE fFIL GRFIVE1 DE:F-TH IS THE I'TINIPT41 DEF"m OF' GFUIVEL. BETWEEI'A THE 01-ITRIL.A.- 'FHE F,.:oTTCjI,I OF.' THE. (IN --jr- j:: V H",71 0-4 H-:, I 1: IEEE :1 ICE C."Ey N »II ic]i F:1 TO RAF'ORIel "ITIP.-H; "EHE: J kI T F'I I I-FIT1011 OF' FiNI-i-I fjE,rFH3ENT ­ff) *YFIIS F.,F'.,f.)PEF.-'.,TY FII ID- I"FIE C'IF" JTIFIT THE L.. ::;EF ',.1E. _N_ ILAA Ell K7 02: on 3: 0%0 QY W EEN __H_, 1 H:::_ -.n 91-III.S, IR IIZ:,,. RE (1]..q L_H ]:: ff:� E K-.:" . ....... 01" FiN"i' SYSTEM AUT110t,'IT FIND FiPPIP.O%.TiI_. Bli-I TFIP; NIIIJ BE TO 111PAIVI1._IM MWAVICIE BETWEEN I? WEL.L. FIND W? OUPSITE SEMIGE f)I:_.';I:wOSF11... SJ, S L T'r--:I,l MEET FOR FI PRIMATE WELL. OR 1.50 TO 200 FEET RION F1 ITUBL.M. I.-JEL.L. DEPEI'-.II".',ING UPON THE PrIFF- OF` PUBI-IC HINTPHRI MSTFINCE. FIRC41 F1 FIRIYATE WEL1. TO f? FRIVATE: SBIER, L.INE: 2F.5 FLE:I-,­.:T F*iI,,IC,, TO F -I I INF,: ISS F-l"T"T. C17TIEF.: RI. -J.) MAY FIFT"i-Y. FINE., ':I V I TO INSLARE FIRCIPPIR INSTALMATICT.I. M Q Q let 1: "A ", F- 1 N IIE--. ol". E,*,,,, EH: 1 -1 KEA EH: Fit .:::1:: -2. a f IL_ 031 H=EN :,:: 1 1.-.:: IT"I"I F`i` TWIT J.: I F111 F-FII-11L.IFIR 1-41"I"Id rkjlii: F'OR, SEENJERS FINE, NJEL.A..' RE; E. -:T F:11.1 JTM CjF, I WYL-L. INS"FAIL, I.. -�;T F T f -E EI, 1 -11,--1 G, OI'+ -SITE SEWINTI: I*,1AY F.Ei-MiM .11-F11'.CREPIEUT IF ME RES I EQN(DE 15FREPIODEL.E13- TO INCUME MORE THEIN I.­.,EID1RCi0I-I,.:-:. h1f.!i!: Pf. ri F. 0 E C, B T,-.. . .. ... ❑ SOILS LOG MUNICIPALITY OF ANCHORAGE= DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION �K PERCOLATION 625 L. Street, Anchorage, Alaska 99501 264-4720 -)A) TEST SOILS LOG - PERCOLATION TEST PERFORMED FOR: DATE PERFORMED: e l — LEGAL DESCRIPTION: DEPTH S / L,7y (FEET) 1 C-) b' 2 � r� 3 4 >v 6 4M1 7 . 8 �I -A 9 �( 10 V 12 13-c' 14 15 16 JF 17 a`() �T 18- 19 C rl 20 �p COMME j —1,�A SITE PLAN CL-�+YeY Cv2a4-vi�G. L / G! -J7 SJ431//�j �2 PERFORMED b x, VfgGIt4Cl~�i -�i13 13P� 72-008 (6/79) Nil ■■f 01 MINI NMI MINI Mimi 0111M .1n, WAS GROUND WATERSp I U ENCOUNTERED? , y L 0 P IF YES, AT WHAT E DEPTH? if Reading Date Gross Net Depth to Net Time Time Water Drop / l -/ c3—jam B 3 h - A 3 3 ; zo Qiw >7fin/ � SJ s�0�1/�✓ PERCOLATION RATE (0 0 TEST RUN BETWEEN FT . CERTIFIEDBYZ&17/ `(Inutes/inch) —!i� FT DA „�GREA ER ANCHORAGE AREA BORuUGH � Department of Environmental Quality 'i— 3330 C Street Anchorage, Alaska 99503 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM _ NAME /l� C �ri�i t/--Z�16`�— MAILING ADDRESS'°X ���5=/T/C'/ycs� PHONE LOCATION />�7 r Nc, c? �- ! t z VI LEGAL DESCRIPTION �`'y / J '!o !•k / ��c o f 20 r�r r'_�' �' SEPTIC TANK: DISTANCE/ NUMBER OF s FROM WELL MANUFACTURER CX ("'C' MATERIAL t. / COMPARTMENTS INSIDE LENGTH INSIDE WIDTH —LIQUID DEPTH LIQUID CAPACITY 101 O GALLONS. SEEPAGE PIT: U /�'� NUMBER OF PITS �_. DIAMETER OR WIDTH �! LENGTH '�� DEPTH 7 —• LINING MATERIAL('�k CRIB SIZE: DIAMETER—DEPTH � DISTANCE FROM: WELL —. TOTAL EFFECTIVE > �t BUILDING FOUNDATION ' l NEAREST LOT LINE ABSORPTION AREA (WALL AREA) SQ. FT. ADDITIONAL ABSORPTION WELL: TYPE CONSTRUCTION BUILDING NEAREST FOUNDATION LOT LINE CESSPOOL OTHER SOURCES APPROVED DISAPPROVED DISTANCES: INSTALLED BY: ` (k < G��9 G e_ PIPE MATERIAL�� LOT SLOPE: 'e<`”"l REMARKS: Form No. EQ -031 DEPTH NEAREST SEPTIC SEWER LINE —, TANK_ REMARKS DIAGRAM OF SYSTEM DISTANCE FROM: SEEPAGE SYSTEM _ C, a I & /:, � : r` , i ."C >Y -i C 'I 1i-IUI L , DATE I �' � APPROVED e>:^ A.A. a " �J TYPE OF SO|L HBSORBTION SYSTEM IS: DRAT NFIELD HHXlMUM NUMBER UF 8EDROOMS ] SOlL fall ING (SQ FT/8Ri40 THE REQUlRED SIZE UF THE SOIL HBSURPTION SYSTEM lS� I� .�������� E � 1 " " - 1`A Q , I~X- 1 qyj 10 �A K Z 2 b" � � YK 501 f �� i� :il i;_L�;�� :::,; ]1:K11 di�l : :l 1 i�� �: 1 X KJ V 9 YG I A 114 & R ��������� BHCKFlLLlNG OF HNY SYSlKEM WlTHOUT FlHHL INSPECTlON HND RPPRUVHL 8Y T||IS 0EPRRTM[N[ WILL 8[ 01-RJEC7 TO PRUSECUTION. HIHYMN |)lSFRA C8ET!MEI'd H WELL HND HNY COO ^SIlE SEWHGE DISPOSHL SYSTEM l' 109 FEET FOR H PRIVHTE 01E LA OR 200 FEET FOR H PU8LIC WELL. ��ECIFi'�STlU�S HHVHlLHBLE TO lNSURE PROPER �����, �i�: 11- ����0 �:� , If li—it I! - 11 � J1 ii, l! ��1! r:� 11 i � ���lg� [I ii, U . �l. 11 � :t� i!" .; f . :� I CERTIFY THHT ` _ 1� l HM FHMlLIHR WITH THE kEQUlR|�MENTS FUR ONK�ITE SEWERS HNC NELLS HS 6�i F0RlH BY THE mum ICIPRLlTY OF ONCHORHGE 2 l NlLL INSTHLL THE 505 MCI IN HCCURDHNCE 141 11 THE CODES. { UN|)ERSTHND THHT TW ON—""lTE SEWER SYSTFM MHY REQUlRE ENLRRGEMENT lF '��� RE�IMNCE M REMODELED lO lNCiUDE MORE THHN ] 8EDROOMS / DOTE / ~ 0 & E GEO eCHNICAL & DEVEL..,PMENT CO. Box 90, Davis St., Eagle River, Alaska 99577 694-2774 or 688-2280 Russell Oyster Earl Ellis 694-2774 SOIL LOG 688-2280 Soils Er Foundations Land Development Performed for: Name:_ Tel. No.. Mailing Address: - -- Legal Description :„--- Death feet) Soil Characteristics 0 1 Ground Water Encountered: Yes______ No If yes, what depth „® Proposed Installation: Seepage Pit_— Drain Field Comments:------- Performed omments:—_.. -- ------ Performed by: - _--- --_-- Date: _ MUNICIPALITY OF ANCHORAGE o Development Services Department -° ? Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Certificate of On -Site Systems Approval Parcel I.D. 050-091-28 1. GENERAL INFORMATION Expiration Date: 0— (a -11-zv 2S Complete legal description SPRING BROOK VISTA #1 BLOCK 1, LOT 1 Location (site address) 12336 E PRINCE OF PEACE DRIVE, EAGLE RIVER, AK 99577 Current property owner(s) MARSHALL & SUSAN UHLIN Day phone Mailing address Real estate agent 1610 HANS WAY, FAIRBANKS, AK 99709 2. TYPE OF DWELLING: ® Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) Day phone 3. NUMBER OF BEDROOMS: 4 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Private Well ❑ Private Septic Water Storage ❑ Holding Tank ❑ Community Well ❑ Community ❑ Public Water System ® Public Sewer ❑ Waiver request for: Distance: Received by: Date: COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ 550 Waiver Fee $ Date of Paymentg�7121 Date of Payment Receipt Number 2-17 10 !!� Receipt Number COSA # d S c 2 r 1 V35 Waiver # 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. I acknowledge that On -Site staff may visit the site to verify the information submitted. Name of Firm FIRST WATER CONSULTING Phone 907-350-9566 Address 13030 SUES WAY, ANCHORAGE, AK 99516 Engineer's Printed Name CURTIS HUFFMAN, PE Date 811312021 Comments: This investigation was completed in compliance with MOA guidelines, regulations, and best industry practices / methods. The assessment of the condition of the well and septic applies only to the conditions as of the day tested. The flow and absorption rates may change due to subsurface conditions that may not be observed from the surface, changes in land use, local soil characteristics, groundwater levels that may fluctuate during the year, quality of construction (workmanship & materials), the water usage of the family being served by the system and maintenance. The operational life of all well and septic systems are subject to these various and dynamic characteristics and are outside the control of the evaluator of thei well and septic system. Therefore, any estimate of how long a system will function satisfactory ��P•' • • !� for current or future occupants or guarantee that no unseen encroachments, deficiencies or discrepancies exist can be given by First Water Consulting & FWCS' *' 9 TH •'* / . ... .. ......... l/�� 6. DSD SIGNATURE Lf �� • • ' Curtis Huffman. •' System #1 Approved for I bedrooms �f��F��s•, CE 128991 System #2 Approved for bedrooms �llPROF SS10 Disapproved Conditional approval for bedrooms, with the following stipulations: J Jti �SER\J Original Certifiluu tb�ate: ce -Z-t M The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other Legal Description: SPRING BROOK VISTA #1 BLOCK 1 LOT 1 Parcel ID: 050-091-28 If more than 1 septic system on lot: COSA Checklist # _of _ Structure served by this system _ A. WELL DATA — PUBLIC WATER ❑ Well log is filed with Onsite (or attached) Date drilled Total depth _ft Cased to _ft ❑ Sanitary seal is functioning correctly ❑ Wires are properly protected Casing height (above ground) _in. Date of flow test for COSA Static water level at beginning of test _ft. Comments B. TANK DATA Age of tank(s) 19 years Tank type/material SEPTIC / STEEL Measured operating fluid level in septic tank 49" ® Standpipes/foundation cleanout per record drawing Date of pumping 8/5/2021 D. ABSORPTION FIELD DATA Well production at time of test _gpm Water storage tank volume_ gallons Well disinfected for coliform test? ❑ Yes ❑ No ❑ Coliform bacteria is Negative Nitrate _mg/L ❑ Nitrate less than MRL (ND) Arsenic ug/L ❑ Arsenic less than MRL (ND) Collected by Date of Sample C. LIFT STATION ❑ Required maintenance completed Age of lift station _ years Lift station material Comments: Which system tested (date installed) 1983 Adequacy test date 8/6/2021 ® ALL standpipes present per record drawing Results 0 Pass For 4 bedrooms Total measured depth from grade *7.5 ft (max) Fluid depth prior to test 11 in Measured depth to pipe invert from grade 5_4 ft (min) Water added 600 gal ❑ N/A — pressurized field New depth 27 in (INTO THE LATERAL) ❑ Monitor tubes go to bottom of effective. If not, state depth into effective 2.17' OF THE 4' ED Elapsed time 1440 min ® Code -required soil cover over field Final fluid depth 11 in ® System presoaked Absorption rate 600 gpd (Required if vacant for greater than 30 days prior to Any rejuvenation treatment (past 12 months) N date of test) Gallons introduced 1800 gallons (up into the lateral) If yes, enter date Comments/Deficiencies: *TOTAL DEPTH AT THE MT. ELEVATIONS SHOW 2.17' MEASUREABLE ED BETWEEN CO/MT. 1976 FIELD MOSTLY SATURATED AS WAS FOUND 2019 COSA W/ NO CHANGES IN LEVELS DURING RECENT TESTING EXISTING FIELDS ARE OPERATING IN THE TOP PORTIONS OF THE EFFECTIVE DEPTH & NO GUARANTEE EWES CAN BE GIVEN ON HOW LONG THE SYSTEM MAY CONTINUE TO FUNCTION. ``= E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well) Septic Tank/Lift Station on Lot > 100' ❑ Yes if No **5+ Community Sewer Manhole/Cleanout > 100' ❑ Yes if No ft ❑ Yes if No Neighboring Tank > 100' ❑ Yes if No ft Private Sewer/Septic Line > 25' ❑ Yes if No Absorption Field on Lot > 100' ❑ Yes if No ft Holding Tank > 100' ❑ Yes if No Neighboring Absorption Fields > 100' if No ft Animal Containment > 50' ❑ Yes if No ❑ Yes if No ft ft If septic tank is under driveway comment below Manure/Animal Excreta Storage > 100' Community Sewer Main > 75' ❑ Yes if No , ft ❑ Yes if No From Septic/Holding Tank on Lot to: (Please enter distances if less than required) Building Foundations > 10' ❑ Yes if No **5+ ft Surface Water > 100' ® Yes if No _ Property Line > 5' ® Yes if No ft Wells on Adjacent Lots: ® Yes Absorption Field > 5' ® Yes if No ft Private Wells > 100' ® Yes if No _ Water Main > 10' ® Yes if No ft Community Wells > 200' ® Yes if No _ Water Service Line > 10' ® Yes if No ft If septic tank is under driveway comment below From Absorption Field on Lot to: (Please enter distances if less than required) Building Foundation > 10' ❑ Yes if No *0 ft If absorption field is under driveway comment below Property Line > 10' ❑ Yes if No *1+ ft Wells on Adjacent Lots: Water Main > 10' ® Yes if No ft Private Wells > 100' ® Yes if No _ ft Water Service Line > 10' ® Yes if No ft Community Wells > 200' ® Yes if No Surface Water > 100' ® Yes if No ft F. ENGINEER'S COMMENTS *MOA WAIVERS ISSUED PREVIOUSLY. **MET CODE AT TIME OF INSTALLATION. G. ENGINEER'S CERTIFICATION I certify that l have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. ape TH •, . • • .. Curtis Huffman : �� FFG, • CE 128991 8(16/21.•AM.�Ap ft ft ft ft ft ft ft ft ENGINEERING a SALES eCONSULTING April 5, 2019 Municipality of Anchorage Development Services On -Site Water & Wastewater Program 4700 Elmore Roade Anchorage, Alaska 99507 Phone: (907) 343-7904 Attention: Tim Eklund Reference: Septic Adequacy Test Results and Drainfield to Foundation Separation Distance for Spring Brook Vista S/D; Block 1, Lot 1 —12336 E. Prince of Peace Drive, Eagle River, AK 99577 Mr. Eklund: We have recently performed a presoak and septic adequacy test on the drainfields for the referenced property. The septic system consists of a 1250 gallon steel septic tank that was installed on 10/15/2002, two (2) deep trenches that were installed in 1976, and another deep trench that was installed in 1983. Based upon the Nome Owner Questionnaire (see attached), the house has been vacant since 11/19/2018. Given the house has been vacant almost 6 months, a presoak was required. On 3/28/2019, we introduced 746 gallons to the 1976 south trench, 756 gallons to the 1976 north trench, and 706 gallons to the 1983 trench. In short, a total of 2,208 gallons was added to the drainfields. The following day we returned to the property and performed the septic adequacy test. Per the inspection report 1976 inspection report, these drainfields have 5 feet of effective. Both the 1976 and 1983 trenches have 2" steel (perforated) monitoring tubes that were driven near the ends of the drainfields into the drainrock in the past. The 1983 trench also has a sump at the southwest end of the trench. Based upon our field measurements, the monitoring tubes do not extend to the bottom of the drainfield, the following is our findings: • In the 1976 south trench, we measured 2.4' difference from the invert of the cleanout at the end of the drainfield to the bottom of the 2" monitoring tube. We also found the invert of the distribution line to be 6.4' below grade. • In the 1976 north trench, we measured 2.3' difference from the invert of the cleanout at the end of the drainfield to the bottom of the 2" monitoring tube. We also found the invert of the distribution line to be 6.1' below grade. • In the 1983 south trench, we measured 3.5' difference from the invert of the cleanouf at the end of the drainfield to the bottom of the 4" sump and 2.2' of difference from the invert of the cleanout at the end of the drainfield to the bottom of the 2" monitoring tube. The invert of the sump is 5.5' below grade and the invert of the cleanout is 5.3' below grade. We would like to note that the elevation difference between the distribution line invert of the sump and the cleanout is approximately 1.7 feet, with the cleanout being at a lower elevation. 3701 East Tudor Road, Suite 101 * Anchorage, Alaska 99507-1259 Phone: (907) 337-6179' Fax: (907) 338-3246 * Website: www.gamessengineering.com Page 2 of 3 On 3/29/2019 (the day after the presoak), we returned to the property to perform the septic adequacy test. The following is a summary of the testing procedure and our calculations of the absorption that should take place in 24-hour period: 1976 — South Trench Prior to adding water, there was 23.5 inches of liquid level in the monitoring tube for this trench. Over a period of 60 minutes, 450 gallons were introduced to the cleanout at the end of this trench, which caused the liquid level to rise to 30.5 inches (a rise of 7"). This brought the liquid level to approximately 2 inches of water in the cleanout. We also checked the liquid level in the monitoring tubes for the other trenches and there was no change in their liquid level. Water was stopped from being introduced and the trench was allowed to recover. The monitoring tube was checked 1197 minutes later and the liquid level was 26 inches deep (2.25" below the invert). Based upon this data the following is the calculated absorption rate: 7" rise with 450 gallons = 64.29 gallons/inch. 4.5" drop X 64.29 gallon/inch = 289 gallons of absorption in 1197 minutes. 289 gallons / 1197 minutes = 0.24 gpm X 1440 minutes in a day = 348 gpd (calculated absorption rate) 1976 — North Trench Prior to adding water, there was 19.75 inches of liquid level in the monitoring tube for this trench. Over a period of 67 minutes, 509 gallons were introduced to the cleanout at the end of this trench, which caused the liquid level to rise to 27.75 inches (a rise of 8"). This brought the liquid level to approximately 0.5 inches in the cleanout. We also checked the liquid level in the monitoring tubes for the other trenches and found there was no change in their liquid level in the 1976 south trench; but did find that the liquid level in the 1983 sump and monitoring tube for the 1983 trench had a 1" rise. Water was stopped from being introduced and the trench was allowed to recover. The monitoring tube was checked 1130 minutes later and the liquid level was 26.25 inches (1.5" below the invert). Based upon this data the following is the calculated absorption rate: 8" rise with 509 gallons = 63.63 gallons/inch. 1.5' drop X 63.63 gallon/inch = 95.45 gallons of absorption in 1130 minutes. 95.45 gallons / 1130 minutes = 0.084 gpm X 1440 minutes in a day = 122 gpd (calculated absorption rate) 1983 Trench Prior to adding water directly to this trench, there was 12 inches of liquid in the sump and 15.75 inches of liquid in the monitoring tube for this trench. Over a period of 90 minutes, 695 gallons were introduced into the cleanout and sump at the end of this trench, which caused the liquid level to rise to 33 inches in the sump and 36.75 inches in the monitoring tube (a rise of 21 inches in both pipes). This brought the liquid level to approximately 9.25 inches below the invert of the sump; however, it did bring the liquid level in the cleanout to approximately 9 inches over the invert of cleanout. We would like to note that the liquid level dropped rapidly in the cleanout upon stopping the introduction of water. We also checked the liquid level in the monitoring tubes for the other trenches and there was no change in their liquid level due to the adding of this water. Water was stopped from being introduced and the trench was allowed to recover. The sump and monitoring tube were checked 290 minutes later and there was 26.25 inches of liquid in the sump (16" below the invert of the sump) and 24.75 inches in the monitoring tube (4 above the invert in the cleanout). We also performed a 2"d recovery reading 1,100 minutes after water had stopped being introduced and found the liquid level to be at 20.5 inches in the sump (21.75' below the invert of the sump) and 24.75 inches in the monitoring tube (1" below the invert in the cleanout). We are assuming that the sump for this drainfield is the most accurate method of monitoring the liquid level in this trench. Based upon this data the following is the calculated absorption rate: 3701 East Tudor Road, Suite 101 ` Anchorage, Alaska 99507-1259 Phone: (907) 337-6179' Fax: (907) 338-3246' Website: www.garnessengineering.com Page 3 of 3 • Using 290 minute recovery reading — 1st recovery reading: 21" rise with 695 gallons = 33.1 gallons/inch. 6.75" drop X 33.1 gallon/inch = 223.43 gallons of absorption in 290 minutes. 223.43 gallons / 290 minutes = 0.77 gpm X 1440 minutes in a day = 1,109 gpd (calculated absorption rate) Using 1,100 minute recovery reading — 2nd recovery reading: 21" rise with 695 gallons = 33.1 gallons/inch. 12.5" drop X 33.1 gallon/inch = 413.75 gallons of absorption in 1,100 minutes. 413.75 gallons / 1,100 minutes = 0.376 gpm X 1440 minutes in a day = 541.6 gpd (calculated absorption rate) This concludes our absorption calculations for all three (3) trenches. Based upon these calculations, it appears the combined absorption rate for all three (3) trench is over 600 gpd at the time of our test. We would like to note that the 1976 trenches appear to be operating in the upper 90% of the absorption area. Given the long-term vacancy of the property, the absorption rate observed may be artificially high. Also, it is important to note that the 1983 trench was deemed failed in 2013. Given these facts, and that fact that the drainfields are over 36 years old, it is reasonable to believe that the drainfields are approaching the end of their useful life. _Drainfield to Foundation Waiver Request Upon review of the records for this property, we have found that a 12 -foot wide garage addition to this house was added to the northeast end of the house. This was concluded by comparing a 2002 as -built survey that performed by James Karl Dowling, RPLS which shows the house dimensions and measured distance from the house to the north lot line; and a 2005 as -built survey (recertified survey in 2009) performed by Fred Walatka, RPLS. It appears this addition took place between 2005 and 2009. In 2010 and 2013, another engineer submitted 2 separate COSA packages stating the drainfields were 10 feet from the foundation and your department approved these COSA's. Based upon our findings, it appears the drainfield encroaches upon the new portion of this foundation and may even possibly run underneath the foundation. The garage foundation appears to be a slab on grade, but there is a possibility the foundation has 4 foot deep footers. Based upon elevation shots we took, the top of the distribution line is 5.5 to 6 foot below grade. In short, the drainfield should be lower in elevation than the foundation footer and should not affect the foundation. We cannot attest to the condition of the drainfield and distribution pipe near or under the foundation. If required, the distribution line could be cameraed and located to determine its condition and its relation to the foundation. We are requesting a 0 foot waiver for the drainfield to the foundation. Please do not hesitte to call us at 337-6179 if you require further information. Thank you for your assistance. nce I , M.S. 3701 East Tudor Road, Suite 101 ` Anchorage, Alaska 99507-1259 Phone: (907) 337-6179' Fax: (907) 338-3246' Website: www.garnessengineering.com ----r---..—"-- • Municipality of Anchorage • P� �_ On-Site Water&Wastewater Program <` (907)343-7904 g 4 5 6 7 e 5" "" �� 9 4. �O •f CERTIFICATE OF ON-SITE SYSTEMS APPROVAL?4, ; o 3- Parcel I.D. 050-091-28 Expiration D tg: • _1 —17 1. GENERAL INFORMATION Complete legal description SPRING BROOK VISTA S/D#1; BLOCK 1, LOT 1 Location (site address) 12336 E. PRINCE OF PEACE DRIVE, EAGLE RIVER,AK 995777 Current Property owner(s) MARSHALL&SUSAN UHLIN Day phone 717-3686 Mailing address 12336 E. PRINCE OF PEACE DRIVE, EAGLE RIVER,AK 995777 Real Estate Agent BRENT SEIBERT Day phone 268-5724 2. TYPE OF DWELLING: • Single Family (w/wo ADU) I Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 4 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well I I Individual On-site In Individual Water Storage ❑ Individual Holding tank ❑ Community Class Well El Community On-site ❑ Public Water System I. Public Sewer ❑ WaiverNariance request for DRAINFIELD TO FOUNDATION Distance: 0 FEET Received by: Date: COSA to be released to the engineer,unless otherwise requested by the engineer. COSA Fee $ 61) Waiver Fee$ Date of Payment 411010 Date of Payment Receipt Number 00-n C) Receipt Number COSA# 65cig1!'o5 Waiver# C/ 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm GARNESS ENGINEERING GROUP, Ltd. Phone 337-6179 Address 3701 E. TUDOR ROAD, SUITE 101 *ANCHORAGE,AK,99507 / Engineer's Printed Name JEFFREY A. GARNESS, P.E. Date if I ' lc) Engineer's Comments: In conducting this evaluation,GEG provided an engineering evaluation of the well and/or septic system in accordance with the .♦♦Vki\*i guidelines and regulations established by the Municipality of Anchorage and industry practices.The reported results describe the ♦♦♦i OF A 4. condition of the system/s on the date/s of the evaluation.Separation distances were measured to readily identifiable features. ♦ \ �• Hidden defects or encroachments may exist that were not identified during the evaluation.The operational life of all wells and septic ♦ .•'��•••••,,•••,•• .. systems depend on a variety of variables including,but not limited to,soil conditions,groundwater levels(that may fluctuate during ••; c �• the year),quality of construction(materials and workmanship),and the water usage of the family utilizing the system/s.These . ;• ,,,\ •L * • conditions can vary,and are outside the control of GEG.Satisfactory test results do not guarantee future performance of the g '" , • system/s:therefore,GEG makes no warranty(express or implied)regarding the future performance of the well or septic system. •• , GEG makes no representation whether an alternative well or septic system can be installed on the property in the event either of the ;„ / current systems fail.The content of this report is for the sole benefit of the person/party who retained GEG.Reliance upon the • �'• 1 A. Gamess :• information provided in this report by any other person or party,including but not limited to subsequent property purchasers,is not ♦ 0 ke __ : kV I a. authorized.In short,GEG disavows any legal duty to anyone other than the person/party who paid for this report. •• i5) C - ;•��� ♦• uv, 6. DSD SIGNATURE (neat•14',0 .•". 'a• •�••' , '♦♦ LICENSE '•III „S"..♦• System #1 Approved for L—f bedrooms. unEcceaa System #2 Approved for bedrooms. Disapproved. Conditional approval for bedrooms, with the following stipulations: e e i� t vle t/' c v'Le* vc C.,wileho-vt c9-1) -C lotic. t Ceti' riBy: '►/V` Original Certificate Date: L/ /�� The Municipality or Anchorage Develop,emt Services Division(DSD)issues Certificates of On-Site Systems Approval(COSA)based only upon the represenatations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTCHMENTS: COSA Checklist ' Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other (Rev.10112/12) COSA Checklist Legal Description: SPRING BROOK VISTA S/D #1 ; BLOCK 1, LOT 1 Parcel ID: 050-091-28 If more than 1 septic system on lot: COSA Checklist# 1 of 1 Structure served by this system 1 A. WELL DATA PUBLIC WATER ■ ' og is filed with Onsite (or attached) Well production at time of test g••• Date drilled Water storage tank volume gallons Total depth ft Well disinfected f• :• orm test? ❑ Yes ❑ No Cased to ft ❑ Co' • •acteria is Negative ❑ Sanitary seal is functioning correctly itrate mg/L ❑ Nitrate less than MRL (ND) ❑ Wires are properly protected : senic ug/L ❑ Arsenic less than MRL (ND) Casing height(above ground) n. Collecte• Date of flow test for CO Date of Sample Static water - •- at beginning of test ft. ents B. TANK DATA C. LIFT STATION Age of tank(s) 16.5 years ■ '-•uired maintenance completed Tank type/material STEEL Age of lift sta •• years • Standpipes/foundation cleanout per record drawing Lift station material Date of pumping 7/18/2018 Comments: D. ABSORPTION FIELD DATA *3 TRENCHES Which system tested (date installed) 1976'1198' Adequacy test date 3/29/19 • ALL standpipes present per record drawing Results Q Pass For 4 feet bedrooms * * Total measured depth from grade ft(max) Fluid depth prior to test in * * Measured depth to pipe invert from grade ft(min) Water added gal ❑ N/A—pressurized field New depth * in ❑ Monitor tubes go to bottom of drainfield. If not, state depth into effective • Elapsed time min * ❑■ Code-required soil cover over field Final fluid depth in ❑■ System presoaked Absorption rate *600+ gpd (Required if vacant for greater than 30 days prior to Any rejuvenation treatment (past 12 months) NO date of test) N/A Gallons introduced *2,208 gallons If yes, enter date Comments/Deficiencies:'SEE ATTACHED REPORT COSA Checklist yellow sheet E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well) Septic Station on Lot> 100' Community Sewer Manhole/Cleanou > :. ❑Yes if No ft II Yes if No ft Neighboring Tank > 100' III '-- ' No ft Private - eptic Line >25' ❑Yes if No ft Absorption Field on Lot > 100' ['Yes if No .► Holding Tank> 100' nYes if No ft Neighboring Absorption Fields> 1 I I' Animal . '.ment> 50' ❑Yes if No ft •Yes if No ft Manure/Animal Excreta S • .=- > 100' Corn . , ewer Main > 75' ['Yes if No ft El ' - ' No ft From Septic/Holding Tank on Lot to: (Please enter distances if less than required) Building Foundations > 10' ❑Yes if No n ft Surface Water> 100' ❑✓ Yes if No ft Property Line >5' n Yes if No ft Driveway/Parking > 0' ❑✓ Yes if No, comment Absorption Field > 5' ❑✓ Yes if No ft Wells on Adjacent Lots: Water Main > 10' ['Yes if No ft Private Wells> 100' ❑✓ Yes if No ft Water Service Line> 10' n Yes if No ft Community Wells> 200' n Yes if No ft From Absorption Field on Lot to: (Please enter distances if less than required) ** Building Foundation > 10' ❑ Yes if No ft Driveway/Parking > 0' n Yes if No, comment Property Line > 10' n Yes if No '••1 + ft Wells on Adjacent Lots: Water Main > 10' n Yes if No ft Private Wells > 100' ❑✓ Yes if No ft Water Service Line > 10' ['Yes if No ft Community Wells> 200' ❑✓ Yes if No ft Surface Water> 100' [' Yes if No ft F. ENGINEER'S COMMENTS 'S'+-MET SEPARATION DISTANCE AT TIME OF CONSTRUCTION**SEE ATTACHED REPORT REGARDING SEPARATION DISTANCE FROM DRAINFIELD TO FOUNDATION"LOT LINE WAIVER GRANTED.SEE WAIVER#WR020073 ao600pp0 G. ENGINEER'S CERTIFICATION o, <.�F .. /116A I certify that I have determined through field inspections and review 0O P . 'V '- of Municipal records that the above systems are in conformance with :. 1 9 H )\ ...-7„;v0 MOA COSA guidelines in effect on this date. VA li, VA �' V f Jeff 1., • Gar ess; p ,/D f E-79. f,1 COSA Checklist yellow sheet \� o f e s s�000� MECC884 OppOo alr. to 4111011... GAR NESS ENGINEERING GROUP, Ltd ENGINEERING SALES CONSULTING Alummimmismoi April 5, 2019 Municipality of Anchorage Development Services On-Site Water&Wastewater Program 4700 Elmore Roade Anchorage, Alaska 99507 Phone: (907) 343-7904 Attention: Tim Eklund Reference: Septic Adequacy Test Results and Drainfield to Foundation Separation Distance for Spring Brook Vista S/D; Block 1, Lot 1 — 12336 E. Prince of Peace Drive, Eagle River, AK 99577 Mr. Eklund: We have recently performed a presoak and septic adequacy test on the drainfields for the referenced property. The septic system consists of a 1250 gallon steel septic tank that was installed on 10/15/2002, two (2) deep trenches that were installed in 1976, and another deep trench that was installed in 1983. Based upon the Home Owner Questionnaire (see attached), the house has been vacant since 11/19/2018. Given the house has been vacant almost 6 months, a presoak was required. On 3/28/2019, we introduced 746 gallons to the 1976 south trench, 756 gallons to the 1976 north trench, and 706 gallons to the 1983 trench. In short, a total of 2,208 gallons was added to the drainfields. The following day we returned to the property and performed the septic adequacy test. Per the inspection report 1976 inspection report, these drainfields have 5 feet of effective. Both the 1976 and 1983 trenches have 2" steel (perforated) monitoring tubes that were driven near the ends of the drainfields into the drainrock in the past. The 1983 trench also has a sump at the southwest end of the trench. Based upon our field measurements, the monitoring tubes do not extend to the bottom of the drainfield, the following is our findings: • In the 1976 south trench, we measured 2.4' difference from the invert of the cleanout at the end of the drainfield to the bottom of the 2" monitoring tube. We also found the invert of the distribution line to be 6.4' below grade. • In the 1976 north trench, we measured 2.3' difference from the invert of the cleanout at the end of the drainfield to the bottom of the 2" monitoring tube. We also found the invert of the distribution line to be 6.1' below grade. • In the 1983 south trench, we measured 3.5' difference from the invert of the cleanout at the end of the drainfield to the bottom of the 4" sump and 2.2' of difference from the invert of the cleanout at the end of the drainfield to the bottom of the 2" monitoring tube. The invert of the sump is 5.5' below grade and the invert of the cleanout is 5.3' below grade. We would like to note that the elevation difference between the distribution line invert of the sump and the cleanout is approximately 1.7 feet, with the cleanout being at a lower elevation. 3701 East Tudor Road,Suite 101 *Anchorage,Alaska 99507-1259 Phone: (907)337-6179*Fax: (907)338-3246*Website: www.garnessengineering.com Page 2 of 3 On 3/29/2019 (the day after the presoak), we returned to the property to perform the septic adequacy test. The following is a summary of the testing procedure and our calculations of the absorption that should take place in 24-hour period: 1976—South Trench Prior to adding water, there was 23.5 inches of liquid level in the monitoring tube for this trench. Over a period of 60 minutes, 450 gallons were introduced to the cleanout at the end of this trench, which caused the liquid level to rise to 30.5 inches (a rise of 7"). This brought the liquid level to approximately 2 inches of water in the cleanout. We also checked the liquid level in the monitoring tubes for the other trenches and there was no change in their liquid level. Water was stopped from being introduced and the trench was allowed to recover. The monitoring tube was checked 1197 minutes later and the liquid level was 26 inches deep (2.25" below the invert). Based upon this data the following is the calculated absorption rate: • 7" rise with 450 gallons = 64.29 gallons/inch. 4.5" drop X 64.29 gallon/inch = 289 gallons of absorption in 1197 minutes. 289 gallons / 1197 minutes = 0.24 gpm X 1440 minutes in a day = 348 gpd (calculated absorption rate) 1976— North Trench Prior to adding water, there was 19.75 inches of liquid level in the monitoring tube for this trench. Over a period of 67 minutes, 509 gallons were introduced to the cleanout at the end of this trench, which caused the liquid level to rise to 27.75 inches (a rise of 8"). This brought the liquid level to approximately 0.5 inches in the cleanout. We also checked the liquid level in the monitoring tubes for the other trenches and found there was no change in their liquid level in the 1976 south trench; but did find that the liquid level in the 1983 sump and monitoring tube for the 1983 trench had a 1" rise. Water was stopped from being introduced and the trench was allowed to recover. The monitoring tube was checked 1130 minutes later and the liquid level was 26.25 inches (1.5" below the invert). Based upon this data the following is the calculated absorption rate: • 8" rise with 509 gallons = 63.63 gallons/inch. 1.5" drop X 63.63 gallon/inch = 95.45 gallons of absorption in 1130 minutes. 95.45 gallons / 1130 minutes = 0.084 gpm X 1440 minutes in a day = 122 gpd (calculated absorption rate) 1983 Trench Prior to adding water directly to this trench, there was 12 inches of liquid in the sump and 15.75 inches of liquid in the monitoring tube for this trench. Over a period of 90 minutes, 695 gallons were introduced into the cleanout and sump at the end of this trench, which caused the liquid level to rise to 33 inches in the sump and 36.75 inches in the monitoring tube (a rise of 21 inches in both pipes). This brought the liquid level to approximately 9.25 inches below the invert of the sump; however, it did bring the liquid level in the cleanout to approximately 9 inches over the invert of cleanout. We would like to note that the liquid level dropped rapidly in the cleanout upon stopping the introduction of water. We also checked the liquid level in the monitoring tubes for the other trenches and there was no change in their liquid level due to the adding of this water. Water was stopped from being introduced and the trench was allowed to recover. The sump and monitoring tube were checked 290 minutes later and there was 26.25 inches of liquid in the sump (16" below the invert of the sump) and 24.75 inches in the monitoring tube (4 above the invert in the cleanout). We also performed a 2nd recovery reading 1,100 minutes after water had stopped being introduced and found the liquid level to be at 20.5 inches in the sump (21.75" below the invert of the sump) and 24.75 inches in the monitoring tube (1" below the invert in the cleanout).We are assuming that the sump for this drainfield is the most accurate method of monitoring the liquid level in this trench. Based upon this data the following is the calculated absorption rate: 3701 East Tudor Road,Suite 101 *Anchorage,Alaska 99507-1259 Phone: (907)337-6179*Fax: (907)338-3246*Website: www.garnessengineering.com Page 3 of 3 • Using 290 minute recovery reading — 1st recovery reading: 21" rise with 695 gallons = 33.1 gallons/inch. 6.75"drop X 33.1 gallon/inch = 223.43 gallons of absorption in 290 minutes. 223.43 gallons / 290 minutes = 0.77 gpm X 1440 minutes in a day = 1,109 gpd (calculated absorption rate) • Using 1,100 minute recovery reading — 2nd recovery reading: 21" rise with 695 gallons = 33.1 gallons/inch. 12.5" drop X 33.1 gallon/inch = 413.75 gallons of absorption in 1,100 minutes. 413.75 gallons / 1,100 minutes = 0.376 gpm X 1440 minutes in a day = 541.6 gpd (calculated absorption rate) This concludes our absorption calculations for all three (3) trenches. Based upon these calculations, it appears the combined absorption rate for all three (3) trench is over 600 gpd at the time of our test. We would like to note that the 1976 trenches appear to be operating in the upper 90% of the absorption area. Given the long-term vacancy of the property, the absorption rate observed may be artificially high. Also, it is important to note that the 1983 trench was deemed failed in 2013. Given these facts, and that fact that the drainfields are over 36 years old, it is reasonable to believe that the drainfields are approaching the end of their useful life. Drainfield to Foundation Waiver Request Upon review of the records for this property, we have found that a 12-foot wide garage addition to this house was added to the northeast end of the house. This was concluded by comparing a 2002 as-built survey that performed by James Karl Dowling, RPLS which shows the house dimensions and measured distance from the house to the north lot line; and a 2005 as-built survey (recertified survey in 2009) performed by Fred Walatka, RPLS. It appears this addition took place between 2005 and 2009. In 2010 and 2013, another engineer submitted 2 separate COSA packages stating the drainfields were 10 feet from the foundation and your department approved these COSA's. Based upon our findings, it appears the drainfield encroaches upon the new portion of this foundation and may even possibly run underneath the foundation. The garage foundation appears to be a slab on grade, but there is a possibility the foundation has 4 foot deep footers. Based upon elevation shots we took, the top of the distribution line is 5.5 to 6 foot below grade. In short, the drainfield should be lower in elevation than the foundation footer and should not affect the foundation. We cannot attest to the condition of the drainfield and distribution pipe near or under the foundation. If required, the distribution line could be cameraed and located to determine its condition and its relation to the foundation. We are requesting a 0 foot waiver for the drainfield to the foundation. Please do not hesit.te to call us at 337-6179 if you require further information. Thank you for your assistance. Sincer ly, gapfey e . ne , . ., M.S. Presid:n 3701 East Tudor Road,Suite 101 *Anchorage,Alaska 99507-1259 Phone: (907)337-6179*Fax: (907)338-3246*Website: www.garnessengineering.com -7- 5 8` ° 50` 5o/rE- 187, 38 /0' U . /L,. E 5M`T i 3c — MD — '- T S r-4 Sd aric' • W PS fENG6 • lJ. 0,-vENrS e. .. :J 01 16 VENO ' 2. / • i. 4 O/ CSP . c'�'•r 3 9. A. Vic . Nli _.k` el M / —z— —� v ill/ c:?� �h Qtf \ qi ‘1. 7 _ Node: c. YYQfer 1V, ,-) Oil site we// ` �t� RE CERTiFf D a-Z5-o9 ,h/. AS-HT NO CORNERS SET THIS DATE ill / _ I herd*ci}rtify that I have performed a Mortgagee's inspection =30 -e'' .'`c.` of the following described property: L-°1- 1, s 4,1....4-4-4‘• ,-*)-3 ,--"*`" .>4e.--44- •c I� SPR/iU: BlZ coo K IV IATA • ti` s ' °).�+ L4 :1 15/af�l U I o. ,. ���,� > __ r ,� Anchorage Recording Precinct, Alaska, and that the ;rev eassn • • .. / r improvensents situated thereon are within the property lines and r •_ _ - do not overlap or encroach on the property lying adjacent .� ' Fred W�bc I - thereto,that no improvements on property lying adjacent thereto M9% ° NO_ a ; encroach on the premises in question and that there are no _-A s•fe. _ _a . J roadways,transmission lines or other visible easements on said "s 1_, property except as:ndicated hereon. ' Dated at Anchorage.Alaska this y` day of 3 UG Y 20 05 EASEMENTS OF RECORD,OTHER THAN FRED WALATKA&ASSOCIATES THOS_E SHOWN ON THE RECORDED 8C (907)248-1666 Engineers and Surveyors PLAT ARE NOT SHOWN HEREON. --1-Ki, • ,Ncnt , Municipality of Anchorages :;...;: :. ki,.,, P.O. Box 196650 • 4700 Elmore Road Anchorage, Alaska 99519-6650 • (907) 343-7904 • Fax (907) 343-7997 http://www.muni.org/Onsite Development Services Division On-Site Water and Wastewater Program **** VARIANCE/WAIVER REVIEW **** Waiver#: COSA#: osc191105 Permit#: PID#: 050-091-28 Legal Description: Spring Brook Vista#1 Blk 1 lot 1 Engineer: Garness Engineering Group Applicant: Marshall Uhlin Your request for a waiver of the required 10 feet horizontal separation from the absorption field to the foundation has been approved. The approved separation distance is 0 feet. This waiver approval applies to the Existing absorption field only. Any future upgrade to the on- site wastewater disposal system will require all separation distances be met or another approval from this department 12 The affected adjacent property owner(s) have been given a 7 day notice regarding this waiver. 0 Notarized letter(s) of nonobjection have been received from the owner(s) of the affected adjacent property. Adjacent properties are not affected by this waiver. Waiver is Granted: X Waiver is not Granted: Date: 1-1'( ,57--q7 Approved by: N me of Reviewer **** VARIANCE/WAIVER REVIEW **** t111 L£ $4 • Municipality of Anchorage On -Site Water and Wastewater Program (907) 343-7904 Certificate of On -Site Systems Approval ,rte Parcel I.D. 050-091-28 Expiration Date: r— J J 1. GENERAL INFORMATION Complete legal description Spring Brook Vista #1, Block 1, Lot 1 Location (site address) 12336 E. Prince of Peace Drive Current Property owner(s) Kay Toup & Stacy Toup Day phone Mailing address 12336 E. Prince of Peace Dr., Eagle River, AK 99577 Real Estate Agent Day phone 2. TYPE OF DWELLING: F Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 4 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well ❑ Individual Fx1 Individual Water Storage ❑ Holding Tank ❑ Community Class Well ❑ Community ❑ Public Water System Q Public Sewer ❑ WaiverNariance request for: Received by:� Date: ^Zv f � COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ `t ` (). 6& Waiver Fee $ Date of Payment b�zr''�//3 Date of Payment Receipt Number 0 oog2 7 Receipt Number COSA#_ D SC13119? Waiver # 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Pannone Engineering Services LLC Address P.O. Box 100217, Anchorage Alk. 99510 Engineer's Printed Name Steven R Pannone 6. DSD SIGNATURE System #1 Approved for bedrooms System #2 Approved for bedrooms Disapproved Conditional approval for Phone (907)272-8218 Date 5/16/2013 bedrooms, with the following stipulations: By E Original Certificate Date: yJ Theuni ' lity of chorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory COSA blue sheet f - c Other If more than 1 septic system is on the lot: COSA Checklist # 1 of Structure served by this system Certificate of On -Site Systems Approval Checklist Legal Description: Spring Brook Vista #1, Block 1, Lot 1 Parcel ID: 050-091-28 A. WELL DATA Well type AWWU If A, B, or C provide PWSID # Well Log (Y/N) Date completed Sanitary seal (YIN) _ Wires properly protected (Y/N) Total depth ft. Cased to ft. Casing height (above ground) in. FROM WELL LOG AT INSPECTION Date of test Static water level Well production 9-p M. g.p.m. WATER SAMPLE RESULTS: Coliform colonies/100 mL Nitrate mg/L Arsenic ug/L Date of sample: Collected by: B. SEPTICIHOLDING TANK DATA Tank Type/Material Septic/ Steel Date installed 10/29/2002 Tank size 1250 gal. Number of Compartments 2 Cleanouts (Y/N) Y Foundation cleanout (Y/N) Y Depression over tank (YIN) N High water alarm (Y/N) N Date of pumping ` Pumper , 'S J �1Pi ✓G� C. ABSORPTION FIELD DATA 1 a1w6l+w1=3 140'1445 sf/br Trench Date installed Soil rating (g.p.d./ft2 or ftz/bdrm) System type Length 56/56 160 ft. Width 4/413 ft. Gravel below pipe 0.5/0.5 14 ft .. 518 98 8" 1 489 Total depth 95/9ft. Eff. absorption area ftz Monitoring tube _ Depression over field N Date of adequacy test 5/15/2013 Results (Pass/Fail) Pass For 4 bedrooms Fluid depth in absorption field before test 22/25174 in. Water added 616 22/ 25129 p p gal. New depth 1n. Elapsed Time: 600 min. Final fluid depth 22/25114 in. Absorption rate , 600+ g.p.d. Any rejuvenation treatment (past 12 mo.) (Y/N & type) If yes, give date D. LIFT STATION Date installed "Pump on" level at in. Datum E. SEPARATION DISTANCES WELL ON LOT TO: Septic tank/h non lot Absorption field on lot_ Public sewer main Sewer containment areas Size in gallVn n ole/Access (Y/N) in. High water alarm level at in. Cycles tested V Meets alarm & circuit requirements? On adjacent lots sewer manhole/cleanout Holding Manure/animal excrete SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5+ Property line 5+ Water main 10+ Water service line 10+ Wells on adjacent lots 200+ ABSORPTION FIELD ON LOT TO: Property line 2 (WR020073) Building foundation 10+ Water Service line 10+ Surface water 100+ Curtain drain 50+ Wells on adjacent lots 200+ Absorption field 5+ Surface water 100+ Water main 10+ Driveway, parking/vehicle storage 5+ F. COMMENTS 3 trenches Z _ 176 Til 5 t Nda/Jff F(i9S33 t'R6Nci< A e waT� * Per permit. I ** Per inspection report. G. ENGINEER'S CERTIFICATION I certify that t have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name Steven R. Pannone Date COSA brown sheet 10-10-12.doc 5/1612013 Municipality of Anchorage • Development Services Department Building Safety Division Ne, On -Site Water and Wastewater Program r, 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907)343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL FOR A SINGLE FAMILY DWELLING Parcell.D. M-091-28 COSA# 1C'Qc�SS Expiratton Date: 1. GENERAL INFORMATION Complete legal description Spring Brook Vista #2� P,IocK -*I-� C oY 1 Location (site address) 12-416 E. Prince Of Peace Drive. Eagle River, AK 99m Current Property owner(s) _Christine Deason Day phone _242-so54 Mailing address 221-46 E. Prince Of Peace Drive, Eagle River. AKg9 Lending agency Day phone Mailing address Real Estate Agent Day phone Mailing Address Unless otherwise requested, COSA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: r_c_ 3. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well ❑ Individual On-site Individual Water Storage ❑ Individual Holding Tank ❑ Community Class Well ❑ Community On-site ❑ Public Water System ® Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given In paragraph 4 by an Independent professional civil engineer registered in the State of Alaska. Certificates of On -Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On -Site Systems Approval are valid for 90 days from the date of Issue for properties served by a private or Class C well and may be reissued with new water sample results. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my Investigation, based on procedures outlined in the Certificate of Onsite Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure Indicated herein. 1 further verify that based on the Information obtained from the Municipality of Anchorage files and from my Investigation and Inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Pannone Engineering Services LLC Phone 272.8228 Address P O. Box 200217. Anchorage. AK ggS2o Engineer's Printed Name Steven R. Pannone. P.E. Date -4 /io Engineers Comments: In conducting an adequacy test, l attempt to provide a thorough, conscientious engineering analysis of the system in accordance with MOA DSD Guidelines & Regulations. The reported results describe the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. o•nr The operational life of all wells and septic systems depend on the local soil condition, ground water ••� OFaaa a levels that may fluctuate during the year, and the water usage of the family being served by the system. �•�p1� »w�w• t Thesc conditions are outside the control of the evaluator of this system All systems eventually fail and satisfactory test results do not guarantee future performance of the system, nor do they guarantee that u 4'9 there are no hidden defects or encroachments. PES can therefore not provide any warranty for future 00""•d •• . »"00 performance nor give any estimate of how long the system will continue to meet the operational a,, _, requirements of the MOA DSD. The content of this report is for the sole benefit of the owner listed � p1Steven R. Pannone/ C above. Any reliance upon or use of this report by any other person or party is not authorized nor will it 0i s No CE 8149 J� confer any legal right whatsoever. 5. DSD SIGNATURE 4aa�ss,Q..• ✓ Approved for _ bedrooms. Disapproved. Conditional approval for bedrooms, with the following stipulations: Attachments: COSA Checklist X Septic System Advisory Well Flow Advisory Nitrate Advisory Arsenic Advisory Maintenance Agreements Supplemental Engineer's Report Other ey: , O Original Certificate Date: 3 — IS/, (Rev. 11A rc Municipality of Anchorage ' I Development Services Department Building Safety Division On -Site Water & Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907)343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Legal Description: _Spring Brook Vista #s. Block i Lot z Parcel ID: 050-o91-28 A. WELL DATA Well type AWWU Date completed _ Total depth ft. Date of test Static water level If A, B, or C provide PWSID fl _ Well Log (Y/N) Sanitary seal (Y/N)_ Wlresjpro�erlyprotected (YM) Cased to ft. asing height (above ground) in. FROM WELL G k) AT INSPECTION ft. Well production f g.An g.p.m, WATER SAMPLE RESU LTS - _c S,: col Nitrate mg/L O bacteria colonies/100 mL Arsenic: ugli Date of sample: _ Collected B. SEPTIC/HOLDING TANK DATA Tank Type/Material Greer Steel Date Installed 20125/2002 Tank size s2So gal. Number of Compartments a Cleanouts (YM) Y Foundation cleanout (YM) y Depression over tank (YM) N High water alarm (YIN) NIA Date of pumping 1183/zoio Pumper SanitaryPumpers C. ABSORPTION FIELD DATA /0/13/7! -'r a Date installed o io i ;I Soil rating (g.p.dJft2 or flz/bdrm) System type Trenche-3 3 j471, 1983 / Trench Leng 1 6o ft. Width t/a ft. Gravel below pipe 6It ft. Total depth y.S/Q.S ft. Eff. absorption area So6/ceo ft2 Monitoring tube y Depression over field N Date of adequacy test - 8hoso Results (Pass/Fail) Pass For g bedrooms Fluid depth In absorption field before 1estAohV6 in. Water added600 gal. New depth3oLULio in. Elapsed Time: 3o min. Final fluid depth o 6 In. Absorption rate >= 600+ g.p.d. Any rejuvenation treatment (past 12 mo.) (YIN & type) No If yes, give date STATION Date insta� Size in gallons "Pump on' level at in. "Pump off' level al —in. Datum E. SEPARATION DISTANCES \ SEPARATION DISTANCES FROM WELL Septic tank/lift station on lot Absorption field on lot Public sewer Sewer Aeolic: service line ole/Acces ) er alarm level at in. alarm 8 circuit requirements? TO: n adjacent lots On ad) t lots Public sewer ma Holding tank _ al containment areas Manure/animal excrete storage areas SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation c+ Property line %o+ Absorption field S+ i Water main 2s+ Water service line so+ Surface water zoo+ Wells on adjacent lots ioo+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: i Property line :'Waived io/a/os Building foundation ao+ Water main 2K+ Water Service line zo+ Surface water aoo+ Driveway, parking/vehicle storage ao+lo.00 Curtain drain None Known Wells on adjacent lots zoo+ F. COMMENTS G. ENGINEER'S CERTIFICATION I certify that I have determined through field Inspections and review of Municipal records that the above systems are In conformance with MOA COSA guidelines In effect on this date. Engineer's Printed Name Steven R. Pannone. P.E. Date /00-20115 COSA Fee $ -7 9 Q Date of Payment — / 0 / (� Receipt Number .7 q -7 0 9 (Rev. 11105) Waiver Fee $ _ Date of Payment Receipt Number, 41 1 ;c ..•• •• l r. �0 i. w..00! nAs,even f.,Po .noo•'rmii � . J Jac: CE'. f lag . SCALE I "--30 f 30' -7 - 6 z r� i 5 Sq° 50' 60"F- /87.38 1 Wcder f'voM IPE CER71F/E D AS -BUILT Rd W' c£u 3-tz -to EASEMENTS OF RECORD, OTHER THAN THOSE SHOWN ON THE RECORDED PLAT ARE NOT SHOWN HEREON. SKD V BE 9 -25-09 VW NO CORNERS SET THIS DATE I hereby certify that I have performeda Mortgagee's inspection of the following described property: COO /r BlLock II SIRIA.I G BRooK VISTA SuBDIVISinN f uNtr IJo, f Anchorage Recording Precinct, Alaska. and that the improvements situated thereon are within the property lines and do not overlap or encroach on the property lying adjacent thereto. that no improvements on property lying adjacent thereto encroach on the premises in question and that there are no roadways, transmission lines or other visible easements on said property except as indicated hereon. Dated at Anchorage, Alaska this /4 71,6 day of J UL y 2065 FRED WALATKA & ASSOCIATES (907) 248-1666 Engineers and Surveyors Municipality of Anchorage far B4 -� Development Services Department Building Safety Division \_ On -Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. KO- 09/- .29 HAA # p5n3U3 Expiration Date: - Z?-- D .� 1. GENERAL INFORMATION ��; Complete�legaldescix'iit ription � 9 YrJl�r._N/ "�ele% Location (site address or directions) e4 Current Property owner(s) Day phone _25'0-995Y ' Mailing address _104�2 A90W /90963 i &iUaAorasrr, fly 9`iS/9 Lending agency Mailing address Real Estate Agent Mailing Address Unless otherwise requested, HAA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: 3. TYPE OF WATER SUPPLY: Individual Well Individual Water Storage Community Class Well Public Water System I" Day phone Day phone TYPE OF WASTEWATER DISPOSAL: ❑ Individual On-site ❑ Individual Holding tank ❑ ❑ Community On-site ❑ Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority Approval (HAA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues HAAs upon request to homeowners. Certificates of Health Authority Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Health Authority Approval Guidelines for this application, shows that the on- site water supply and/or wastewater disposal system is(are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Eagle River Engineering Services Name of Firm 10421 VFW , Suite Phone 6941- 5`1157' Address Eaqle River, AK 99577 Engineer's Printed NameWA9D Date 5. DSD SIGNATURE ✓ Approved for L� bedrooms. Disapproved. Conditional approval for bedrooms, with the following :E :: U,'.= Additional Comments WATER AND Attachments: HAA Checklist X Septic System Advisory Well Flow Advisory Maintenance Agreements Supplemental Engineer's Report Other By: / �il�. Original Certificate Date: ;2-a - O S IRIv. 0IM2) Municipality of Anchorage • Development Services Department Building Safety Division On -Site Water & Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 HEALTH AUTHORITY APPROVAL CHECKLIST' Legal Description: I n%Ial &a� rS�u Parcel ID: L)iO- A. WELL DATA Well typeZ&c If A, B, or C provide PWSID # _ Date completed _ Sanitary seal (Y/N) Total depth ft. Cased to ft. FROM WELL LOG V Date of test V Static water level r h, ft. Y Well production 5 g.p.m. 0 WATER SAMPffESULTS: Cotifor Ncolonies/100 ml. Nitrate mg.A. rsemc: mg./I. Date of sample: _ B.S PJJGMOLDING TANK DATA Tank Type[Mat�_Aid _. Tank size 4_,22 gal. Number of Compartments 2 - Weil Log (Y/N) _ Wires properly pr ed (Y!N) Cas fight (above ground) in. AT INSPECTION ft. Other bacteria colonies/100 ml. Collected by: Date installed / 14,q 1403- Cleanoutsa,/N) YIW- Foundation cleanout (9N) Depression over tank (Y() Y,&- High water alarm (Y61 nLA nD f Date of pumping % �l g /0f Pumper R 1 S C. ABSORPTION FIELD DATA /iy/.2/7(o ydS c� 60Date installed bio /Q3 Soil rating (g.p.d./ft2 or ft /bdr ) To System type ` . �.� Length /7a- ft. Width 1/Z x d�x B.,Oft. Gravel below pipe Z>, ft. iHb'0+gq6)&o1X y'D Total depth a -/1 � ft. Eff. absorption area l, 5'_7 ft Monitoring tube Depression over field - el, - (0 0 �nn�- Date of adequacy test 11 1 k3 Results 5 ail) ForLIL bedrooms N 33%37'%11" Fluid depth in absorption field before test _ in. Water added gal. New depth_ in. jZrr/1S•�7n Elapsed Time: 1140 min. Final fluid depth _/ in. Absorption rate >= 40 g.p.d. Any rejuvenation treatment (past 12 mo.) (Yl6)& type) N 0 If yes, give dateAi* D. LIFT STATION Date installed Size in gallons 'Pump on' level at _ in. 'Pump off' Cycles tested r11/ E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: e ti ift station on lot /001 t Absorption field on lot / 00 r f Manhole/Access (Y/N) ra er alarm level at in. Meets alarm & circuit requirements? On adjacent lots 0 ad' ots Public sewer main , 5tZ N,3V Public sewer manhole/cleanout Sewer /se e line Holding tank SEPARATION DISTANCES FROMZ�OLDING TANK ON LOT TO: Building foundation S/ Property line S "- Water - Water main 40 ' Wells on adjacent lots t 1o0 Absorption field S Water service line 4 10 ` Surface water IOU, f - SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line e 2 r Building foundation f 10 r Water Service line t10 Surface water [On' (- Curtain drain ROIL �V,,L Wells on adjacent lots t / kjr _ _ ) �_ F. COMMENTS G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA HAA guidelines in effect on this date. Engineer's Printed Name HiQ/ITO�IE� . ct1CkY� Date 7/11 HAA Fee $ q30 Date of Payment Receipt Number. -7119,101-- (Rev. 1,Irl,1uS'(Rev. 12101) Water main -)tv r Driveway, parkingNehicle storage S Waiver Fee $ Date of Payment Receipt Number 'OPHER R. CE -1Q387 Municipality. of Anchorage u Development Services Department =f- ' j;�` _ e . u.9.Nyaa SNP x .Building Safety Division On-Site Water and Wastewater Program SAFETY 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK .99519-6650 www.ci.anchorage.ak.us (907) 343-7904 "'ER T iPICATE OF HEALTH AUTHORITY APPROVAL FOR H SINGLE FAMILY DWELLING Parcel I.D.: D • pc) 1 7-4 ` Expiration Date: 1 — Jr Q - 1. `' GENERAL°iNFORMATION Completelegal SPRTIJ6 Moor- VLS/A¢ #1 1'3 LK 1 Location (site address or,directions) 1233 6 C, PRY-ma DF PEAL b `Current Property ownei (s) y'St✓R�Y L LL� �J ?T S 5 Day phone 2 SCS ' 9 %q Mailing address ` PD 60x 190763 Lending agency Day phone Mailing address Real Estate Agent Day phone Mailing Address -- Unless otherwise requested, HAA will be held by DSD for pickup. 2.J NUMBER OF BEDROOMS: 3. TYPE WATER SUPPLY:* TYPE OF WASTEWATER DISPOSAL: -OF Individual Well - _ ElIndividual On-site Individual Water Storage6" ❑ Individual Holding tank ❑ Community Class Well ❑ Community On-site ❑ Public Water System [� Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority Approval (HAA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues HAAs upon request to homeowners. Certificates of Health Authority Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results. (Certificates may be reissued for a period of up to one year'with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. As certified by my seal -affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Health Authority Approval Guidelines for this application, shows that the on- site water supply _and/or wastewater disposal system is(are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm CA(h,.LE Address 1577 Engineer's Printed Name Date- 6 I.IA z -w -L2j CHRISTOPHER R. WOOL" 5. DSD SIGNATURE CER TV Approved for bedrooms. Disapproved. Conditional approval for bedrooms, with the following stipulations: Ott( Y OF Additional Comments ON-SITE ov( ♦ 0 --------- --- WITE��• M 4STj=W.4Tr:D W, STEWATER *.—PRO"AM— ♦ SEV TT Attachments: HAA Checklist X Maintenance Agreements Septic System Advisory Supplemental Engineer's Report Well Flow Advisory Other By: Original Certificate Date:— (Rev, 01/02) n Municipality, of Anchorage "1 Development Services Department j Building Safety, Division On-Site Water & Wastewater Program,: 4700 South Bragaw St. ;P.O. Box 196650 Anchorage, AK 99519-6650 i 9 ! www.ci.ancho�age.ak.us f l � I 1. 907 343 7904 EALTH 'AUTHORITY APPROVAL CHECKLIST !* : K I Pa cel ID: 450 09I Legal Description: 9P(U (j 6R�c9K V%ST� L A. WELL DATA c ;I II I PWSID # Wel l:o Y/N If A B or C provide9 ( ) Well type' u � Y Date (completed Sanitary seal (Y/N) Wires prope�ly'protected (Y/N) r r in. Total'depth ft. Cased to ft. i i Casing height (above g ound) i FROM WELL LOG : II AT INSPECTION , I. I: I ;I :Date of test I I Static water level ft. ft II� IA } -Well production 9 p.m. ai i! a ! I WATER SAMPLE RESULTS: i /100 ml. • bacteria colon es rate • m ./I. Othe Niitra Iies/100 ml � N Mg ./I. m' coon l; I � 1 I� Date of 'sample: Collected by: llF � I • DING TANK' DATA ( i• ;B ,SEPTIC HOL I I s I I .i i . •Ii ! I: {!' S Date installedyf02 Tank Type ateri T�� 1r ! — YP E, .I Z Cleanouts N y f om artments Num o C Tank size, J al. Nu p ( ) i— 9 I �i. Foundation cleanout Y' �IDepression over tank (Y J�i High water alarm (YT1 It) /f "l/c� ly,. ; •..I r, �2,s � p�n►nPr�,iG ;' Dat23 e of pumping l0 0 3 Pumper Or C ,ABSORPTION FIELD DATA 4L1 !' { Date in., Iv 3�.; . Soilrating (g:plcJ.Ift� o ftp/bdr ;System type T 1ZC�" (3� Length' il' 1 'l2- " ft', Width I12�x" Ili �X `vJ ':ft. ;Gra lIlbelow pipe t/ r po4t r 2 i' i Id ft Mon�itonn tube De ress on over fie 'I - Ir tion area • t .Eff. abso 9 P Total'de h / � p ��'I I P .� , !I y-6' `• i i � •SII 4 Date of adequacy test �l Results I(PassAFA#) I'P j� :I For bedrooms� I 137 //I>,► I, ��_ ��� 3y/a9/r8 in. Water added al. 1.' New depth in. iFlwd depth in absorption field before test,_� ,, „ I �1Z9 I � a,. I P I 3Z�3S r Elapsed Time: olmin. Final fluid d pth l in Absorption rate >_ �OD g.p.d. "t o If yes give date rejuvenation treatment (past 12 mo. Y i f r D. UFT STATION Date installed "Pump on" level at in. Datum E SEPARATION DISTANCES Size ingallons "Pump off'Ieve|atin Cycles tested Manhole/Access 0YN>_ High water alarm level at Meets alarm & circuit requirements? /x SEPARATION D�TANCESFRDK8VYELLONLOT TO: A//�� ift station onlot Onadjacent lots Absorption field onlot Onadjacent lots Public sewer main Sewer /septic service line Public sewer manhole/cleanout SEPARATION DISTANCES F OLD|NGTANK DNLOT TO: Building foundation (+ Property line S /f~ Absorption field Water main t /} VV atersemice|ine / Surface water i0 ' +- Wells on adjacent lots _LQl/__'__ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Prooedv line ^z- Bui|dingfoundaUon / 4- VVab* man /0/f- . ' - / ' / Water Service line /(2 Surface water /00 f~ Driveway, parking/vehicle storage s8'f- Curtain drain ^) Wells on adjacent lots _hlc_r` F. COMMENTS � � '�LPAZIV-lr /I:- G. ENGINEER'S CERTIFICATION /certify that / have determined through ~ field inspections and review ofMunicipal records that the above systems are in conformance with MOA HAA guidelines /neffect onthis date. Engineer's Printed Name � Date Lo - �� HAA3 0 RaoeiptNumber Waiver Fee $ Date of Payment Receipt Number in. Eagle River Engineering Services Christopher R. Wood, P.E. 10421 VFW Rd, Suite 201 (907) 694-5195 tel Eagle River, AK 99577-3294 (907) 694-3297 fax December 30, 2003 Jim Cross, P.E. Manager, On -Site Services Municipality of Anchorage P.O. Box 196650 Anchorage, AK 99519 Re: Spring Brook Vista #1 Ll, B1 Adequacy Test and Health Authority Approval Dear Mr. Cross: Eagle River Engineering Services (ERES) was contracted by Jerry Lewis to perform an adequacy test and secure a Health Authority Approval (HAA), for the above referenced property. During the records search portion of the process, it was noticed that several other engineers had done work for the client over the past year and a half. ERES arrived on site, and after a brief site survey, verified that there were 2 separate existing permitted leachfields, each with new cleanouts and monitor tubes that were installed within the last year. Additionally, a new larger septic tank had been installed just a year prior to our involvement with this client. The oldest existing leachfield was the original leachfield. This system was designed, built, and approved for 3 bedrooms in 1976. This system consisted of a 1,000 gallon septic tank with 2 leachfield lines, 56 feet long, 4 feet wide, and 6 feet of sewer rock in each line. Monitor tubes and cleanouts were added in 2002. The second leachfield was added in 1983, and was designed and permitted for 1 additional bedroom. The leachfield is 60' long, 3 feet wide, and 4 feet deep. A monitor tube and cleanout were added in 2002. The combined existing leachfields are designed and permitted for a total of 4 bedrooms. The newly added 1250 gallon septic tank is also of adequate size for a 4 bedroom house. The leachfield was therefore tested with a minimum of 600 gallons to determine if its absorption capacity is sufficient for a 4 -bedroom house. ERES decided that the water should be applied at one of the after tank cleanouts, to allow it to flow to each separate leachfield as it would under normal usage. The appropriate amount of water was added for a 4 bedroom single family residence. Water levels were measured to rise in each leachfield, and then recover to at or below the water level readings prior to the addition of the test water. The leachfields appeared to be functioning adequately, and capable of absorbing \2003\03-071 SErnCNARRATivE.Doc the required amount of liquid. We can only speculate on why the system was previously failed by another engineer. ERES is submitting as -built documentation for the new 1250 gallon septic tank as part of this HAA application. Additionally, a current survey as -built showing the locations of the newly installed monitor tubes and cleanouts is also being provided. If you have any questions please call our office at 694-5195. Sincerely, AEER EN.7RING RVICES Woo, \2003\03-071 SEPricNARRATIVEMOC F— APPL.IC NT FILLS OUT UPPER HAL ONLY Date Properly Owrr^r '�` r ; �.:,• ,( `•. f'r- I �I • C' Phone / : �( ,' 1f �� ��- ., < �' Inspector Inspector t Field Notes:MUN Zip Code t , / ��l A �L- C >S`I C[� ��_ r4 \ i� i S– �6 l Mailing Address Buyer (� APPROVED BEDROOMS 'CONDITIONS OF APPROVAL ( ) DISAPPROVED ( ) CON�.D�IT10NAL APPROVAL' Zip Code Address Soils Rating Date Sewer Installed Well 7o Absorption to Tank �— — Well Phone Lending Institution Zip Code _ Address — Phone Realty Co. & Agent Zip Code _ Address — _ Legal Description Street Location': Type of Residence d�Single Family ❑ Multiple Family No. of Bedrooms ❑ Other _ Water Supply SIT ATTACH WELL LOG. A well log is required for all wells drilled since June 1975. ❑ Individual- ��^^ For wells drilled prior to that date, give well depth (attach log if available). Co nmunity=i' L NZI ❑ Public Utility — Sewer Disposal Year Individual Installed: 13.46dividual When Connected to Public Utility: ❑ Public Utility ❑ Holding lank _ — -- NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. 4 T Time Time --:—�:: Time Date Date Date Date Inspector Inspector Inspector Inspector Field Notes:MUN ICIPALITY OF ANCHORAGE t , / ��l A �L- C >S`I C[� ��_ r4 \ i� i S– �6 l Z DEPT . OF H`T:LTI{ ENVIR OV( ,CENTAL PROTECtION H-o(d (� APPROVED BEDROOMS 'CONDITIONS OF APPROVAL ( ) DISAPPROVED ( ) CON�.D�IT10NAL APPROVAL' DATE Soils Rating Date Sewer Installed Well 7o Absorption to Tank �— Well Log Received Are Q /� Septic Tank Size Well 12023(31 ) October 10, 1983 'I'o ':'.'hom i. t May Concern: I certify that as o_ today there are 18 homes existinc; in Spring Brook Vista Subd., Prince of: Peace Drive, Eagle River. (These are a to -Lai of 27 lots in the Subdivision. Ten of. these logs have not been bui.l_t on and remain vacant. Those lots remain.ing vacant are Lots 2,3,4,5,7,9 ')-oc.': Lois 3,:i,6 and 7, Block .1_.) IC 1 can be oF further assistance, please call me, �t 694-9008. S-incCrely, vert` 5/ johnsin, member hoard of Oi_rectors 1',O. Pox, 357 Nagle R_i_ver, Alaska 995/7 14 INSPECTION APPOINTMENTS DATE RECEIVED �el� j 7Z E"GU'7J �C-t I/CV STREET LO ATIO i 1m i TIME TIME TIME DATE DATE DATE INSPECTOR INSPECTOR INSPECTOR MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH &ENVIRONMENTAL PRMOfl r� „ 825 L Street - Anchorage, Alaska 99501 ,U611 • ENVIRONMENTAL SANITATION DIVIS Telephone 264-4720 J U L 13 1983 REQUEST FOR APPROVAL OF INDIVIDUAL WATER AND'2fiW,,,,KRtf,$CA4jQ,, DIRECTIONS: Complete all parts on page 1. Incomplete requests will not be processed. Please allownAlM9WWI fArilteet}Wj . 1. PRO �WNER K INDIVIDUAL/ON-SITE** �2 �7--YEAR ON-SITE SYSTEM WAS INSTALLED. ❑ PUBLIC UTILITY MAILIN -ADD SSS PROPERTY RESIDENT (If differOt from above) PHONE 2. BUYER ' < ete PHONE MAILING ADDRESS U 3. LENDING INSTITUTION `K PHONE / ;7 MAILING ADDRESS 4. REALTOR/AG N- PHONE MAILING ADDRESS 5. LEGAL E CRIP O 7Z E"GU'7J �C-t I/CV STREET LO ATIO i 1m i 6') 'l 6. TYPE OF RESIDENCE T—I_N MBER OF,BEDROOMS �"INGLE FAMILY ❑ One ❑ Four ❑ Other _ ❑ Two ❑ Five ❑ MULTIPLE FAMILY Cid Three ❑ Six 7. WATER SUPPLY ❑ INDIVIDUAL* *ATTACH WELL LOG. A well log is required for all wells drilled [K COMMUNITY since June 1975. For wells drilled prior to that date, give well ❑ PUBLIC UTILITY depth (attach log if available.) B. SEWAGE DISPOSAL SYSTEM K INDIVIDUAL/ON-SITE** �2 �7--YEAR ON-SITE SYSTEM WAS INSTALLED. ❑ PUBLIC UTILITY NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. 72-010 (Rev. 6/79) 72-010 (Rev. 6/79) l g�3 THIS SIDE FOR OFFICIAL USE ONLY 1. TYPE OF RESIDENCE ❑ SINGLEFAMILY ❑ MULTIPLE FAMILY NUMBER OF BEDROOMS ❑ ONE ❑ THREE ❑ FIVE ❑ TWO ❑ FOUR ❑ SIX ❑ OTHER 2. WATER SUPPLY ❑ INDIVIDUAL ❑ COMMUNITY ❑ PUBLIC UTILITY Connection Verified PERMIT NUMBER DEPTH OF WELL DATE DRILLED LOG RECEIVED 3. SEWAGE DISPOSAL SYSTEM ❑INDIVIDUAL/ON -SITE ❑PUBLIC UTILITY Connection Verified PERMIT NUMBER DATE INSTALLED I — INSTALLER ❑Septic Tank or ❑ Holding Tank Size: 2000 Tank is homemade give dimensions: SOILS RATING TYPE OF TANK MANUFACTURER TOTAL ABSORPTION AREA MATERIAL 4. DISTANCES WELL T0: Septic/Holding Tank Absorption Area Sewer Line Nearest Lot Line Absorption Area to nearest Lot Line 5. COMMENTS o. k-, ❑ APPROVED FOR BEDROOMS ❑ CONDITIONAL APPROV (letter mus accom any certificate) DISAPPROVED DATE 7 BY 72-010 (Rev. 6/79) l g�3 ttgr11�'Ito Audrey Mason Totem Realty P.O. Box 911 Eagle River, EXCAVATION Alaska 99577 WORK July 24, 1983 Dear Mis. Mason, Reference: Lot 1; Block 1; Springbrook Vista ROBERT A. SHAFER CIVIL ENGINEER 6942979 A sewer system adequacy test was performed on the system located on the referenced property as you requested. The septic tank was "pumped and verified to have a capacity of _1000 gL-dons. The absorption trench was tested by a continuous flow of water over a period of 48 hours. It was noted during this time that the water backed into the septic tank in the first 24 hour period. T e flow was tYien reduced and during the second 24—hour period the system appears to accept approximately 300 gallons of water. It can be concluded from this test that thought the septic tank is adequate for three bedrooms the absorption trench appears to only be adpn>>?te for approximately two bedrooms. It will be necessary for you to navethe sys em u it can be considered adequate for the three bedroom residence located on this property. we have made arrangements to have a soil test performed in the vicinity of the proposed upgrading. As soon as this work is completed it will. be submitted to vou. If we may be of further service, please do not hesitate to contact us. .E. cc: Municipality of Anchorage Department of Health and Environmental Protection SRB 196X EAG} -E RIVER, ALASKA MUNICIPALITY OF ANCHORAGE \. `DEP`AR-TMENT`._C'. HEALTH AND ENVIRONMENTAL 'ROTECTION 825 L Street, Anchorage, Alaska 99501 'l��i fid fl 2.79--2511, ext. 224, 225 a "J 11 Date Received: March 30, 1977 lst Inspection: Time 2:30 p.m. y� 2nd. inspection: Time Date 3-31-77 Thursday inspector Dixson Date Inspector REQUEST FOR APPROVAL OF INDIVIDUAL SEWER AND WATER FACILITIES 1. Lending Institution Request: Alaska Bank of Commerce Mailing Address: Pouch 7-012 99510 Phone: 279-5641 2. Property Owner: _ Eric S. Johnson _ _ Phone: 694_9734 Mailing Address; Box 722 Eagle River `99577 3. Legal Description: Lot.1 Block 1 Springbrook Vista Subdivision , n 4. Single Family Residence: (x) Number of Bedrooms: _ "2 Multiple Family Residence: ( ) Number of. Bedrooms: /J/� 5. Well. Data: Type Community Depth Well Log Filed 'N`6- Construction `' Bacterial Analysis 6. Sewage Disposal System: On-site system (x) Public Utility ( ) Permit 76726 _ Installed 1976 Installer�� Septic Tank Size MOO O Manufacturer Absorption Area -< —t —�— Soils Rate �T_ Material 7. Distances: Well to Septic Tank j o c to Absorption Area �� C to Sewer Lines Nearest Lot Line AbsorptionArea to Nearest Lot Line.�� Page '.Cceo Department of Health and Environmental Protection Request for Approval of individual_ Sewer and Water Facilities Legal Description: :Lot 1 Block 1 SpringBrook Vista Subdivision _ Comments: Af.fadavit Attached: ( ) Letter Attached: ( ) Approved: Disapproved: Department Worksheet: Date: Date: MUNICIPALITY OF ANCHORAGE Department of Health and ]Envir.onmenta:i 825 L Street, Anchorage, Alaska 99501T.0' 279-2511, e<It. 224, 225 %:iVIMMOFMM_ r,: -c: :TION, est for Approval of Individual Sewer and WaterhlM`SaWs 1.. Property Owner: ';: C I V Mailing Address: -12 ?j'��� Phone:j5�/ 2. Name of Buyer: Mailing Address: Phone: 3. Lending Institution: Mailing Address: /�rJLF{�y�,=)� - _ cls< Phone: 4. Realtor/Agent: Mailing Address: - _ Phone: 5. Legal Description: Street Location: 6. Single Family Residence: (4-T�_ Numbe.r of Bedrooms: _ Multiple Family Residence: ( ) Number of Bedrooms: 7. Water Supply: *Individual Well ( ) Public/Community System (L� If Individual Well, well depth If Community System, name of system 8. Sewage Disposal System: On-site System (j/� Public System ( ) If On-site System, date of installation:' *NOTE: A well log is required on ALL wells drilled since 6/75. 3/77