Loading...
HomeMy WebLinkAboutRIVER VIEWESTATES BLK 8 LT 15River View Estates Lot 15 t; A( M1.7 0 M r, 1.0� Y, 0 W, A P. MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Water & Wastewater System Permit Permit Number: OSP241154 Work Type: WellSeptic Initial Tax Code Number: 05079246000 Site Legal Address: RIVER VIEWESTATES BILK 8 LT 15 G:0357 Site Mailing Address: 21426 RIVER PARK DR, Eagle River Owner: LUTZ DANIEL & REBEKAH Design Engineer: FORGE ENGINEERING This permit is for the construction of: Effective Date Expiration Date: Lot Size in Sq Ft: Total Bedrooms: 6/26/2024 6/26/2025 43826 Q Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy Q Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened an_Giosed,.on the e or b. Covered Baled, and ed to preven reezing cial Provisions: F' • An additional percolation test is required prior to construction of the septic field. Please submit stamped and signed results with the As -built Inspection Report. If the results require a design change, construction of the system will stop pending On -Site review and approval. Receive�By: _T a —to /'01 �, c-- Date: Issued By: Date: Z C- _ MUNICIPALITY OF k "'T Community Development Department Development Services Division On -Site Water & Wastewater Program R05iA ANCHORAGE Phone: 907-343-7904 Fax: 907-343-7997 ON-SITE SEWERIWELL PERMIT APPLICATION Parcel I.D. 050-792-46 Property owner(s) Daniel & Rebekah Lutz Day phone (920) 905-3050 Mailing address 10433 Colville Street, Eagle River, AK, 99577 Site address 21426 River Park Drive, Eagle River, AK, 99577 Legal description (Sub'd., Block & Lot) River View Estates, Block 8 Lot 15 Legal description (Township, Range & Section) Lot Size 43,826 _Sq. Ft. Number of Bedrooms 4 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (N all that apply) Absorption Field FX� Initial rK Single Family (SF) FX] (w/wo ADU) Septic Tank FX Upgrade n Duplex (D) ❑ Holding Tank F Renewal Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well RX Water Storage F THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: g 20Z Waiver Fees: Date of Payment: 4/," -7 I -Z-,4 617- ZOate of Payment: Receipt Number: 061,31$1D C0/90,VReceipt Number: Permit No. 0-5 P 2-q 1 15 �j Waiver No. Permit App_-'- : - :-'.,'c I June 25, 2024 MOA Development Services, On-Site Water & Wastewater Program 4700 Elmore Rd Anchorage, AK 99507 Subject: River View Estates, Block 8 Lot 15 – 21426 River Park Drive Septic system design Dear On-Site Services Engineer: The owner of the above lot intends to build a 4-bedroom home on the property, so we are submitting this permit application for the construction of a new well and septic system. The attached site plan identifies the location of the home as well as the proposed well, septic location and alternate site. No conflicts exist between this proposed system and any other well or septic system, whether on this lot or adjacent lots. The ground surface on the lot slopes toward the road steeply near the back of the lot, in some areas approaching 45%. Near the front of the lot the slopes are much milder, just under 25%. It is in that flatter area that the new septic system is located. There are no slopes greater than 25% within 50 feet downslope of either the primary or alternate site. Contours are shown on the site plan showing the grade and direction of flow. Stormwater drainage will not impact this septic system. The new trench will be constructed parallel to the slope as much as possible. A portion of this trench will need to be constructed under the driveway in order to meet all separation distances. The standpipes will not be under the driveway and will be accessible. For freeze protection we have specified 4” of insulation (in lieu of the standard 2” if it were just shallow bury). The trench consists of a pipe with sewer rock beneath it; insulation, pipes, and rock all have standard use in road construction and will not cause any structural problems for the driveway. Manufacturer’s technical bulletin provides a minimum burial depth for 4” D3034 PVC sewer pipe as 1’. We meet that minimum and are confident that this meets the exception in AMC 15.65.210.B.5.a. Wells on this and adjacent lots are shown. The new system will be a minimum of 100’ from all wells and surface water, and more than 5’ away from the septic tank. The alternate site is located more than 6’ away. Please refer to the attached test hole logs, plan and profile pages for the septic design. If this design is followed, there will be no adverse impacts to adjacent properties. Sincerely, Benjamin Schiller, PE Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP241154, Deb Wockenfuss, 06/26/24 Benjamin Schiller CE 12592REGISTEREDPROFESSION A L E N GINEER 1"=40' CO - CLEANOUT 2CO - DOUBLE CLEANOUT FCO - FOUNDATION CLEANOUT FS - FLOW SPLITTER VALVE MH - MANHOLE MT - MONITORING TUBE SV - SEPTIC VENT TH - TEST HOLE LEGEND RIVER VIEW ESTATES, BLOCK 8 LOT 15 FEET 0 40 80 SEPTIC PLAN 6/21/24 RIVER PARK DRIVE 10' UTILITY EASEMENT 560 550 570 580 590 600 530 540 540 EXISTING SHED PRO P O S E D 4 -BD R M H O M E PRO P O S E D GAR A G E PROPOSED WELL w/ 100' RADIUS ESTIMATED LOCATION OF NEIGHBORING WELL w/ 100' RADIUS TH#1 CONFIRMATION TEST HOLE TO BE DUG PRIOR TO CONSTRUCTION 2x 60' LONG x 5' WIDE, 6" EFFECTIVE DEPTH ABSORPTION TRENCHES PROVIDE 4" INSULATION UNDER DRIVEWAY MT MT MT MT CO CO CO COFCO 1250-GAL SEPTIC TANK 2CO FS ALTERNATE SITE: CAT III 30' LONG, 5' WIDE, 6" EFFECTIVE DEPTH ABSORPTION TRENCH 6.0 >10.0 >10.0 ESTIMATED NEIGHBORING 100' WELL RADIUS NEIGHBORING SEPTIC SYSTEM ESTIMATED NEIGHBORING 100' WELL RADIUS >5.0 >10.0 AREA OF DISTURBANCE Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP241154, Deb Wockenfuss, 06/26/24 TYPICAL TRENCH SECTION (NO SCALE) NOTES: 1. GRADE AREA OVER TRENCH TO DRAIN AWAY 2. PROVIDE 3' OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2' WITH 2" OF INSULATION 3. CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY Benjamin Schiller CE 12592REGISTEREDPROFESSION A L E N GINEER 6" 2'-6" 6" DESIGN FACTORS:SYSTEM REQUIREMENTS: 600 GPD PEAK FLOW PERK RATE: <1 MIN/IN APPLICATION RATE: 1.00 GPD/SF 5' WIDE TRENCH SYSTEM 1250-GAL SEPTIC TANK BOTTOM OF TRENCH: 3' 6" BELOW GRADE FLOW LINE ELEVATION: 3' BELOW GRADE 600 GPD / 1.0 GPD/SF (/ 5' WIDE * 1.00 RED FACTOR [6" DEEP]) = 120 LF TRENCH REQUIRED (120 LF SPECIFIED) 6" 6/17/24 5' 4" PERFORATED PVC (HOLES DOWN) DRAINFIELD ROCK GEOTEXTILE FABRIC PROVIDE ADDITIONAL FILL TO ACCOUNT FOR SETTLEMENT 2' MOA-APPROVED SAND 2' RIVER VIEW ESTATES, BLOCK 8 LOT 15 NOTE: PROVIDE 4" INSULATION UNDER DRIVEWAY EXTEND 1.5' BEYOND SIDES 1'-6" Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP241154, Deb Wockenfuss, 06/26/24 LEGAL DESCRIPTION: PERFORMED FOR: DATE: PARCEL ID#: SOILS LOG AND PERCOLATION TEST 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 DEPTH (feet) TEST HOLE 1 DATE READING START TIME NET TIME (minutes) DEPTH to WATER NET DROP PERCOLATION RATE: (MIN/INCH) (inches)(inches) DATE OF MONITORING WAS WATER ENCOUNTERED? DEPTH TO WATER AFTER MONITORING IF YES @ WHAT DEPTH? 0.03 6/4 1 2 3 4 5 GM (SANDY GRAVEL) Professional Engineers Stamp: NO RIVER VIEW ESTATES BLOCK 8 LOT 15 6/4/2024 050-792-46 DANIEL LUTZ 11:11 1 0 16 2' OB 0:05 Benjamin Schiller CE 12592REGISTEREDPROFESSION A L E N GINEER PERC TEST LOCATION TECHNICIAN: J.OPHEIM 7 0 16 - NONE 6/11/24 COMMENTS: SITE PLAN 6 0 16 USCS SOIL CLASSIFICATION WAS VISUALLY DETERMINED 6/17/24 11:12 1 0 160:07 7 0 16 6 0 16 11:13 1 0 160:09 7 0 16 6 0 16 11:15 1 0 160:10 7 0 16 6 0 16 11:17 1 0 160:10 7 0 16 6 0 16 6TH PERC TEST WAS UNABLE TO BE PERFORMED DUE TO HOW FAST THE SOIL ABSORBED THE WATER 6 11:17 1 0 160:10 7 0 16 6 0 16 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP241154, Deb Wockenfuss, 06/26/24 SOIL SOIL TYPE Loose Slight < 85% Proctor, Moderate 85% - 95% Proctor, High > 95% Proctor, CLASS (Unified Classification Systema) < 40% relative density 40% - 70% relative density > 70% relative density Class V Fine-grained Soils (LL>50)b Soils with medium to high plasticity No data available; consult a competent soils CH, MH, CH -MH engineer; Otherwise use E' = 0 Class IV Fine-grained Soils (LL < 50)Soils with medium to no plasticity 50 200 400 1,000 CL, ML,ML-CL, with less than 25% coarse-grained particles Fine-grained Soils (LL < 50)Soils with medium to no plasticity CL, ML,ML-CL, Class III with more than 25% coarse-grained particles 1004001,0002,000 Coarse- 100 4001,000 2,000 grained Soils with Fines GM, GC, SM, SCC contains more than 12% fines Class II Coarse-grained Soils with Little or No Fines GW, GP, SW, SPC 200 1,000 2,000 3,000 contains less than 12% fines Class) Crushed Rock 1,000 3,000 3,000 3,000 Accuracy in Terms of Percentage Deflection t2 t2 t1 t0.5 a ASTM Designation D 2487, USBR Designation E-3 b LL = Liquid limit `Or any borderline soil beginning with one of these symbols (i.e. GM -GC, GC -SC) d For ± 1 % accuracy and predicted deflection of 3%, actual deflection would be between 2% and 4%. Note: Values applicable only for fills less than 50ft (15m). Table does not include any safety factor. For use in predicting initial deflections only; appropriate Deflection Lag Factor must be applied for long- term deflections. If bedding falls on the borderline between two compaction categories, select lower E' value or average the two values. Percentage Proctor based on laboratory maximum dry density from test standards using about 12,500 ft-Ib/cu ft (598,000 J/m3) (ASTM D 698, AASHTO T-99, USER Designation E-11). 1 psi = 6.9kN/m2. Source: "Soil Reaction for Buried Flexible Pipe" by Amster K. Howard, U.S. Bureau of Reclamation, Denver Colorado. Reprinted with permission from American Society of Civil Engineers Journal of Geo- technical Engineering Division, January 1977, pp. 33-43. A pipe system designer uses this equation to predict PVC pipe deflection given type of PVC pipe, burial depth, soil density, type of traffic, type of embedments oil, and compaction density of embedment soil. The designer then compares the predicted deflection to there commended maximum deflection in Table 1 to check if the burial depth is appropriate. Example 1: Shallow Burial A pipe system designer is interested in using ASTM D3034 SDR 35 PVC sewer pipe in a shallow -burial installation with the following characteristics: -1 foot burial depth: - 120 pounds per cubic foot soil density - H2O highway traffic - sand embedment material - 90% Proctor density embedment soil compaction % DEFLECTION = % DEFLECTION = 0.1 (P+W1) 100 0.149 (PS) + 0.061 E1 0.1 (0.83 + 12.5) 100 0.149 (46) + 0.061(2,000) % DEFLECTION = 1.0 ±1 % The maximum predicted deflection is 2.0%, well below the maximum recommended for PVC sewer pipe in lable 1 O 11/2%. Minimum Burial Depth: The minimum recommend- ed burial depth for PVC pipes beneath a highway is one foot. This recommendation assumes proper specifi- cation of embedment materials and compaction, and proper installation. Example 2: Deep Burial A pipe system designer is interested in using ASTM D3034 SDR 35 PVC sewer pipe in a deep -burial instal- lation with the following characteristics: - 45 foot burial depth - 120 pounds per cubic foot soil density - H2O highway traffic (Note: Live loads are negligible for deep burials) - sand embedment material - 90% Proctor density embedment soil compaction % DEFLECTION = 0.1 (P+W') 100 0.149 (PS) + 0.061 E' % DEFLECTION = 0.1 (37.5 + 0) 100 0.149 (46) + 0.061(2,000) % DEFLECTION = 1.0 ±1 % The maximum predicted deflection is 3.9%, well below the maximum recommended for PVC sewer pipe in Table 1 of 71/2%. For more information, see the following JM Eagle Technical Bulletins: - PVC Pipe Trench Construction - Deflection Testing of PVC Sewer Pipe - PVC Sewer and Drain Pipe Burial Depth Charts - PVC Water Pipe Burial Depth Charts Page 3 of 4 MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Section Phone: 907-343-7904 Fax. 907-343-7997 Septic System Owner -installer Agreement The On-site Water and Wastewater Section (On-site) may issue an approval for a homeowner to perform work on an on-site wastewater disposal system to serve that individual's owner - occupied, single-family or duplex home if the homeowner meets and agrees to the following requirements: 1. The property owner and excavation equipment operator may perform work on no more than one owner -installation project in a 12 -month period. 2. Owner's projected active involvement with the installation: 3. The name of the excavation equipment operator:. /•> 4. 1 agree that there will be no monetary compensation for installation services rendered. 5. The name of the inspecting engineer: 1 ce; 6. 1 agree to discuss the following items with the inspecting engineer: a. Permit design criteria and specifications. b. Inspection requirements set forth in AMC 15.65.070. c. Advance notice given to the On-site Water & Wastewater Section for all required municipal inspections (AMC 15.65.070A). 7. 1 agree to have the project -specific On-site Wastewater Disposal System Permit available at the construction site for the duration of all related work. 8. 1 agree that if the system is an advanced wastewater treatment system (AWWTS), I will obtain additional installation instructions and approval from the equipment distributor. As owner of (legal description) La /$^ 1 agree that the information above is true and accurate. Owner's printed name: Dc. " L Owner's signature: rr.2 Date: PO�¢