ON-SITE WASTEWATER INSPECTION REPORT
Permit Number: OSP241209 PID Number: 017-092-71
Dwelling: X Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: ❑■ New ❑ Upgrade
Name
Hultquist Homes Inc
ABSORPTION FIELD
❑■ Deep Trench ❑ Wide Trench ❑ Bed ❑ Mound
Site Address
14311 Pickett Street
❑ Other
Phone
Number of Bedrooms
Soil Rating
Total depth from original grade
4
0.6 GPD/SF
10.0 Ft.
LEGAL DESCRIPTION
Depth to pipe invert from original grade
3.0 Ft.
Gravel depth beneath pipe
7.0 Ft.
Subdivision Block Lot
Equestrian Heights 2 16
Fill added above original grade
1.3-1.0 Ft.
Gravel length
2 @ 36 Ft.
Township Range Section
Gravel width
2.5 Ft.
Beds: Number of Lines
NA
Distance between lines
NA Ft.
SEPARATION
DISTANCES
To
Septic
Absorption
Holding Sewer
Total absorption area
Number of trenches
Dist. between trenches
From
Tank
Field
Lift Station
Tank Line
100$ Ft2
2
10.0 Ft.
Well
100'+
100'+
NA
NA 25'+
TANK XSeptic [:1S.T.E.P. El Holding El Other
Manufacturer
Greer (Deep Bury)
Capacity
1250 Gal.
Surface Water
100'+
100'+
NA
NA
Material
HDPE
Number of compartments
2
Lot Line
5'+
101+
NA
NA NA
Foundation]
10'+
10'+
NA
NA
LIFT STATION
Manufacturer
Capacity
Gal.
Remarks *Waiver request attached.
Alarm location
Electrical installed by
PIPE MATERIAL House to tank 3034 Tank to
drainfield 3034
Installer
Hultquist Homes Inc
Drainfeld 3034 CO/MT 3034
Inspector Pannone Engineering Services
BENCH MARK (Assumed elevation) 100.0 ft
Inspectiones: X51 8/13/24 8/14/24
Location and description
2„d
3rd 8/16/24 4`" 10/16/24
Garage FF
ON-SITE WATER AND WASTEWATER SECTION APPROVAL
Engineer's Stamp
Conditional A royal: Date
PP
1, 44
�� Steven R. Pannone"
Septic Syste. m.
cF 81 49.`,,
Approved ' Date
PP
ovzv1 ,
�] s�F;,- ...
,l `O,C
r ,
Note:
F6 s\oyr
this approval does not include well permit require ents
(Rev 05/02(A8)
PA
N
N
O
N
E
E
N
G
S
V
C
,
L
L
C
(
C
.
I
.
1
0
8
8
)
1250 GAL GREER
POLY TANK
PA
N
N
O
N
E
E
N
G
S
V
C
,
L
L
C
(
C
.
I
.
1
0
8
8
)
A SCALE: NTS
WASTEWATER SYSTEM PROFILE
B SCALE: NTS
DRAIN FIELD SECTION
www.sullivanwaterwells.com
Pump Installation Log
Well Drilling Permit Number: OSP 241209 Date of Issue 7/22/24
Parcel Identification Number: 0709271000
Legal Description Property Owner Name & Address
EQUESTRIAN HEIGHTS
BLK 2 LT 16
Hultquist Homes
14311 Pickett St.
Anchorage, AK 99516
Pump Installation Date:
8/6/24
Pump Intake Depth Below Top of Well Casing:
315 feet
Pump manufacturer’s Name:
Grundfos
Pump Model:
10SQE15-330
Pump Size:
1.5 hp
Pitless Adapter Burial Depth:
15 feet
Pitless Adapter Installer:
Pitless Manufacturer:
Disinfected Upon Completion?
yes no
Method of Disinfection:
Chlorine 50 PPM
Comments:
Pump Installers Name:
Sullivan Water Wells
Attention: The pump installer shall provide a pump installation log to the DSD within 30 days of pump installation.
Merrill
White Raven
Certified Drilling Log
OWNER OF LAND: Hultquist Homes
ADDRESS:
LEGAL DESCRIPTION Equestrian Heights Block 2 Lot 16
DATE: 7-22-24
PERMIT NUMBER: OSP241209 DATE OF ISSUE: 7-22-24
TAX IDENTIFICATION NUMBER 01709271000
Is well located at approved permit location: Yes No
Method of Drilling: air rotary cable tool
Depth of Well: 400’
Casing Type: Steel Wall thickness .250 inches
Diameter: 6 inches, depth 100 feet
Liner type 300’ of 4.5” PVC
Static Water Level: 56.9 feet
Recovery Rate 5+ gpm gph
Method of Testing Air
Well Intake Opening Type: open end open hole
Screened Start feet Stopped
Perforations Start feet Stopped
Grout Type: Bentonite Volume: 50 lbs
Depth: from 2 feet, to 42 feet
Well Disinfected Upon Completion: yes no
Method of Disinfection: Chlorine 50 PPM
Comments:
Bore Hole Data
Depth
From To
0 2 Casing Stickup
2 4 Overburden
4 20 Silt Sand & Gravel
20 30 Silty Sand & Clay
30 40 Silt Sand & Gravel
40 60 Silt Gravel & Some Clay
60 90 Silt & Gravel
90 100 Bedrock Soft
100 320 Bedrock Gray
320 356 Bedrock Fractured
356 400 Bedrock Fractured with Fallout
Drillers Name: Cole Sullivan
ATTENTION: It is the responsibility of the property owner to submit a copy of the well log to the proper authority.
Municipality of Anchorage: Department of Health & Human Services and/or Department of Environmental Conservation.
MatSu Borough: Department of Environmental Conservation.
X111 �"
wfAnchorage
. Urpontmenr
P.O. Box 196650 0 4700 Elmore Road
Anchorage, Alaska 99519-6650 0 (907) 343-7904 0 Fax (907) 343-7997
http://www.muni.org/Onsite
Development Services Division
On.-Site Water and Wastewater Program
* * * * VARIANCE/WAIVER REVIEW * * * *
Waiver#: OSV251005 COSA#:OSC251024 Permit#:OSP241209
PID#: 017-092-71
Legal Description: EQUESTRIAN HEIGHTS BILK 2 LT 16
Engineer: Pannone Engineering Services
Your request for a waiver of the required 14 feet horizontal separation from the absorption field
to the other field of the duel trench system has been approved. The approved separation distance
is 10.0 feet.
This waiver approval applies to the existing absorption field only. Any future upgrade to the on-
site wastewater disposal system will require all separation distances be met or another approval
from this department.
............................................... ■ ............................. ■ 1
Waiver is Granted: X Waiver is not Granted:
Date: Approved by:
Name of Reviewer
.............................................................,., ............... 1
**** VARIAN C E/WAIVER REVIEW ****
Pannone Engineering Services LLC
Steven R. Pannone, Principal
Registered Professional Engineer
E-mail: steve@panengak.com
Mailing: P.O. Box 1807 Palmer, AK 99645
Telephone: (907) 745-8200 FAX: (907) 745-8201
Municipality of Anchorage
Development Services Department
On-Site Water & Wastewater Program
4700 Elmore Road
Anchorage, Alaska 99519
Subject: Equestrian Estates Block 2 Lot 16
Drain Field to Drain Field Separation Waiver Request
Ladies and Gentlemen:
We hereby submit a waiver request for the subject property. We are requesting a waiver to a distance of 10.0
feet between the drain fields installed on the subject property. The drain fields were laid out with the
appropriate separation distance prior to construction. During construction the eastern drain field drifted
toward the western drain field. This separation distance could not be verified during construction due to the
location of temporary soil storage piles, drain rock, and other construction equipment.
AMC 15.65 requires a separation of 6 feet or two times the effective depth which ever is greater between
adjacent drain fields. The subject drain fields were installed 10 feet apart, 4 feet closer than the 14 feet
required by 15.65.
The soils in this area are typically Hydrologic Soils Group A which contains organics underlain by silty sand
and gravel. The soil composition and percolation rate confirms the soil classification of HSG A. Due to the
nature of the drainage capacity of the soils found in the area. An infiltration line of 45% is used to provide an
assumed infiltration path for effluent in the system.
It can be seen on the attached section that the assumed infiltration line for the uphill, eastern most drain
field intersects the drain rock of the downhill, western most drain field. Approximately 60.7% of the west
drain fields effective depth is below the assumed infiltration line of the eastern drain field. It should be noted
that even if the drain fields were spaced as required by 15.65, approximately 53.1% of the west drain fields
effective depth would be below the assumed infiltration line of the eastern drain field.
Granting this waiver request will not pose any adverse risks to public health or the environment. If you have
any questions or concerns, please contact me at 907 745 8200
Sincerely,
SRP
Steven R. Pannone, P.E. F.ASCE
Owner/Civil Engineer
21 January, 2025
MUNICIPALITY OF ANCHORAGE
On -Site Water & Wastewater Program
PO Box 196650 4700 Elmore Road
Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997
hftp://www.muni.org/onsite
On -Site Water & Wastewater System Permit
Permit Number: OSP241209
Work Type: WellSeptic Initial
Tax Code Number: 01709271000
Site Legal Address: EQUESTRIAN HEIGHTS BLK 2 LT 16 G:3038
Site Mailing Address:
Owner: HULTQUIST HOMES INC
Design Engineer: PANNONE ENGINEERING SERVICES
This permit is for the construction of:
Effective Date:
Expiration Date:
Lot Size in Sq Ft:
Total Bedrooms:
7/22/2024
7/22/2025
22545
2 Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy 0 Private Well ❑ Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
4
Received By:
L�-�P e- S
Date:
Issued By:
Date:
7 202
MUNICIPALITY OF
. . . . . . . . . .
Community Development Department
Development Services Division
On -Site Water & Wastewater Program
Phone: 907-343-7904
Fax: 907-343-7997
ON -SITE SEWERIWELL PERMIT APPLICATION
Parcel I.D. 017-092-71
Property owner(s) Hultquist Homes
Mailing address 12570 Old Seward Hwy Anchorage, AK
Site address NHN Pickett Street
Day phone
Legal description (Sub'd., Block & Lot) Equestrian Heights B2 L16
Legal description (Township, Range & Section)
Lot Size 22,545 _Sq. Ft. Number of Bedrooms 4
APPLICATION IS FOR:
APPLICATION IS AN:
TYPE OF DWELLING:
(Z all that apply)
Absorption Field
Rx
Initial RX
Single Family (SF) RX
(w/wo ADU)
Septic Tank
[i]
Upgrade R
Duplex (D) ❑
Holding Tank
R
Renewal
Multiple Dwellings ❑
Privy
El
(SF and/or D)
Private Well
RX
Water Storage
R
THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
�40
(Signature of property owner or authorized agent)
Permit/Rush Fees:
Date of Payment:
Receipt Number:
f?
Permit No. cl-1-1--) ?� 1 1209
Waiver Fees:
Date of Payment:
Receipt Number:
Waiver No.
Permit App_-'- : - :'c ,
Pannone Engineering Services LLC
Steven R. Pannone, Principal
Registered Professional Engineer
E-mail: steve@panengak.com
Mailing: P.O.Box 1807, Palmer, AK 99645
Telephone: (907) 745-8200 FAX: (907) 745-8201
Municipality of Anchorage
Development Services Department
On-Site Water & Wastewater Program
4700 Elmore Road
Anchorage, Alaska
Subject: Equestrian Estates B2 L16
Private well and Septic System Permit Request
This is a design narrative for a permit to install a well and septic system on the subject property. The proposed
upgrade will serve a proposed four (4) bedroom house. This lot and surrounding lots are served by private wells.
Currently there are no wells within 100 feet of the proposed installation.
1. Soils: A test hole was performed on this lot by Pannone Engineering Services, LLC on 6/27/2024. Groundwater
was not observed during the excavation of the test hole, and bedrock was not encountered. No groundwater
was observed in the test hole monitor tube after 7-days. Based on the results of the percolation test, sieve
analysis and overall soils appearance an application rate of 1.2 gpd/SF was used for the design of a conventional
wastewater treatment system in the area of the test hole.
2. Soil Absorption System Design: See Sheet 1 of the design package.
3. Surface Water: There is no surface water within 100 feet of the proposed septic tank and drain field.
4. Topography: See attached site plan for area topography. The slope down gradient of the drain field is
approximately 26% based on MOA lidar. This installation conforms to the steep slope provisions of AMC 15.65.
5. Drawing Markings: The Drawings are marked “For MOA Review Only”. When written notification that the
review is complete and no further comments are received from MoA On-Site Department, the note will be removed
and “For Construction” drawings will be issued.
The proposed installation will not affect the future development of this or the surrounding lots.
If you have any questions or concerns, please contact me at (907) 745-8200.
Sincerely,
SRP
Steven R. Pannone, P.E. F. ASCE
Owner/Civil Engineer
15 July 2024
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP241209, Curtis Townsend, 07/22/24
PA
N
N
O
N
E
E
N
G
S
V
C
,
L
L
C
(
C
.
I
.
1
0
8
8
)
2.2. SCOPE OF WORK: INSTALL SYSTEM IN ACCORDANCE WITH THE ATTACHED DESIGN AND SPECIFICATIONS.
16 FEET
16 FEET
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP241209, Curtis Townsend, 07/22/24
PA
N
N
O
N
E
E
N
G
S
V
C
,
L
L
C
(
C
.
I
.
1
0
8
8
)
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP241209, Curtis Townsend, 07/22/24
PA
N
N
O
N
E
E
N
G
S
V
C
,
L
L
C
(
C
.
I
.
1
0
8
8
)
A SCALE: 1"=10'
DRAIN FIELD SECTION
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP241209, Curtis Townsend, 07/22/24
PA
N
N
O
N
E
E
N
G
S
V
C
,
L
L
C
(
C
.
I
.
1
0
8
8
)
COMMENTS: Test hole excavated by HULTQUIST HOMES.
PERFORMED BY: PANNONE ENGINEERING SERVICES, LLC. I CERTIFY THAT THIS TEST
WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDLINES
IN EFFECT ON THE DATE OF THIS TEST.
·24 (min/inch)
·6"
·3 FT AND 4 FT
SOILS LOG & PERCOLATION TEST
·<1.0 (min/inch)
·6"
·- FT AND - FT
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP241209, Curtis Townsend, 07/22/24
040.002 Crowther Associates
1632 Bellevue Circle / Anchorage, Alaska 99515
Telephone (907) 349-2198 / E mail: 907crowther@gmail.com
Date:July 5, 2024
Client:Pannone Engineering Services, Aaron
Project:Equestrian Heights, Block 2, Lot 16
Particle Size Distribution Table
(percent passing subject sieve size)
Sample Source Test Pit
Moisture
Content
2%
Sieve Size Percent Finer Percent Finer Percent Finer Percent Finer
3 inch 100
1-1/2 inch 100
¾ inch 94
#4 67
#10 43
#40 10
#100 3
#200 2
0.02 mm xx
Classification Gravelly Sand
(SP)
Invoice 219
MUNICIPALITY OF ANCHORAGE
Development Services Department Phone: (907)343-7904
On -Site Water & Wastewater Section Fax: (907)343-7997
Certificate of On -Site Systems Approval
OSC251024
Parcel ID 017 -092-71 Expiration Date: 8/6/2025
Legal description EQUESTRIAN HEIGHTS BILK 2 LT 16
Site address 14311 PICKETT ST
Current property owner(s)
HULTQUIST HOMES INC
X The On-site system(s) is/are approved for 4 bedrooms
Conditional approval for bedrooms, with the following stipulations:
Comments or conditions:
Original Certificate Date:
1/31/2025
This Certificate of On -Site Systems Approval (COSA) is intended to demonstrate the subject
sy4t6m(s) is/are in substantial compliance with municipal code. The Municipality of Anchorage,
&velopment Service Department (DSD) issues COSAs based upon representations provided by an
independent professional engineer. The Municipality of Anchorage is not responsible for errors or
omissions in the professional engineer's submittal.
ATTACHMENTS:
COSA Checklist X Well Flow Advisory
Absorption Field Advisory Nitrate Advisory
Tank Age Advisory Arsenic Advisory X
Other
MUNICIPALITY OF ANCHORAGE
Development Services Department J Phone: 907-343-7904
On -Site Water & Wastewater Section Fax: 907-343-7997
Certificate of On -Site Systems Approval Application
1. GENERAL INFORMATION
Parcel I.D. 017-092-71
Complete legal description Equestrian Heights B2 L16
Location (site address)
14311 Pickett Street Anchorage, AK
Current property owner(s) Hultquist Homes,lnc
2. ON-SITE SYSTEMS SIZED FOR 4 BEDROOMS
Day phone
3. TYPE OF WATER SUPPLY: X Private Well ❑ Private Well serving 2 dwelling units
❑ Private Well serving 3+ dwelling units ❑ Community Well or Public
❑ Water Storage
4. TYPE OF WASTEWATER DISPOSAL: ❑■ Private Septic ❑ Private Septic serving 2 dwelling units
❑ Holding Tank ❑ Community Septic or Public Sewer
5. SEPTIC TANK: ❑ Steel ❑■ Plastic ❑ Concrete ❑ Fiberglass
Age New - See advisory if steel older than 20 years
6. ABSORPTION FIELD: ❑ AWWTS ❑ Bed ■❑ Deep Trench ❑ Wide Trench ❑ Seepage Pit
Waiver request for: Drain field to drain field separation
Expedited review requested: ❑
Distance: 10.0
By applying for this entitlement, this property is subject to inspection by municipal On-site staff
to verify the accuracy of the information provided.
COSA Fee $ 75 Waiver Fee $ ) `i
Date of Payment Date of Payment / Z 2
COSA# DS C2 `��1D2 `� Waiver# ��w2,5�aD5
COSA Application—June 2022
COSA Checklist_June 2022
COSA Checklist
Legal Description: Parcel ID:
If more than 1 well and/or septic system on lot, provide separate checklist. Structure served by this system ____
A.WELL DATA
Well log is filed with Onsite (or attached)
Date drilled Total depth ft
Cased to ft
Sanitary seal is functioning correctly
Wires are properly protected
Casing height (above ground) in.
Date of flow test for COSA
Static water level at beginning of test ft.
Well production at time of test gpm
Water storage tank volume gallons
Well disinfected for coliform test? Yes No
Coliform bacteria is Negative
Nitrate mg/L Nitrate less than MRL (ND)
Arsenic ug/L Arsenic less than MRL (ND)
Collected by
Date
Comments __________________________________________________________________________________
B.TANK DATA
Measured operating fluid level in septic tank
Date of pumping
Required maintenance completed, if AWWTS
Comments:
C. LIFT STATION
Required maintenance completed
Age of lift station years
Lift station material
Comments:
D.ABSORPTION FIELD DATA
Which system tested (date installed)
ALL standpipes present per record drawing
Total measured depth from grade ft (max)
Measured depth to pipe invert from grade ft (min)
N/A – pressurized field.
Per record drawings, field is insulated.
Monitor tubes go to bottom of effective.
If not, state depth into effective
Presoaked required if
(Required if house vacant or field not used for more
than 30 days prior to date of test)
Gallons introduced gallons date
Any rejuvenation treatment (past 12 months)
If yes, enter date
Adequacy test date
Results Pass
Fluid depth prior to test in
Water added gal
New fluid depth in
Elapsed time min
Final fluid depth in
Absorption rate gpd
FIELD STATUS – POST RECOVERY
Effective depth (per record drawings) in
Effective depth used in
Effective depth remaining in
Comments/Deficiencies:
COSA Checklist_June 2022
E. SEPARATION DISTANCES
From Private Well on Lot to: (Please enter distances if less than required or if community well on lot)
Septic Tank/Lift Station on Lot > 100’
Yes if No ft
Neighboring Tank > 100’ Yes if No ft
Absorption Field on Lot > 100’ Yes if No ft
Neighboring Absorption Fields > 100’
Yes if No ft
Community Sewer Main > 75’ Yes if No ft
Community Sewer Manhole/Cleanout > 100’
Yes if No ft
Private Sewer/Septic Line > 25’ Yes if No ft
Holding Tank > 100’ Yes if No ft
Animal Containment > 50’ Yes if No ft
Manure/Animal Excreta Storage > 100’
Yes if No ft
N/A – Served by Community Well (not on lot) or Public Water
From Septic/Holding Tank and Absorption Field(s) on Lot to: (Please enter distances if less than required)
Building Foundations > 10’ Yes if No ft
Tank to Property Line > 5’ Yes if No ft
Field to Property Line > 10’ Yes if No ft
Water Main > 10’ Yes if No ft
Water Service Line > 10’ Yes if No ft
Surface Water > 100’ Yes if No ft
Wells on Adjacent Lots:
Private Wells > 100’ Yes if No ft
Community Wells > 200’ Yes if No ft
If tank or field is under driveway comment below
F.ENGINEER’S COMMENTS
G.CERTIFICATION & STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on
procedures outlined in the Certificate of On-Site Systems Approval Guidelines, indicates that the on-site water supply
and/or wastewater disposal system appears to comply with applicable Municipal and State codes, ordinances,
and regulations in effect at the time of installation, unless noted otherwise.
In conducting an adequacy test, I attempt to provide a thorough, conscientious engineering analysis of the system in
accordance with ADEC & MOA guidelines and regulations. The reported results describe the performance of the system
under the conditions encountered at the time of the test, and separation distances measured to readily identifiable
features. The operational life of all wells and septic systems depend on the local soil condition, ground water levels that
may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside
the control of the evaluator of this system. All systems eventually fail, and satisfactory test results do not guarantee future
performance of the system, nor do they guarantee that there are no hidden defects or encroachments. Therefore, we
cannot provide any warranty for future performance, nor can we estimate remaining life of the system. The content of this
report is for the sole benefit of the owner listed above.
Name of Firm
Phone
Engineer’s Printed Name
Date 01/21/2025
DEVELOPMENT SERVICES DEPARTMENT
on -Sine Water and Wastewater Section
www.rnuni.org/onsize
Arsenic Advisory
Certificate of On -Site Systems Approval # OSC251024
Subdivision: Equestrian Heights, Block: 2, Lot: 16
907-343-7904
Fax: 343-7997
A water sample revealed an arsenic concentration of 74.8 micrograms per liter
(ug/L). The Environmental Protection Agency (EPA) has established a maximum
contaminant level (MCL) of 10.0 ug/L for public drinking water systems. While
private wells are not subject to this regulation, EPA standards are based on existing
health information and can therefore be used to gauge the relative quality of water
from private wells. information on arsenic is available from the On -Site Water and
Wastewater Program website (www.muni.org/onside) or at 343-7904.
This advisory must be attached to all copies of the subject Certificate of On -Site
Systems Approval.
Lot 16, Block 2,
Equestrian Heights Subdivision
As Built
Land Surveying
Land Development Consultants
Subdivision Specialists
Construction Surveying
AEC# 173042
S4
Group
124 E 7th Avenue
Anchorage, Alaska 99501
(907) 306-8104
mail@S4AK.com
12/12/2024