Loading...
HomeMy WebLinkAboutDEARMOUN #2 BLK 2 LT 8Block 2 • Municipality of Anchorage On -Site Water and Wastewater Section - (907) 343-7904 Page 1 of 3 ON -SITE WASTEWATER INSPECTION REPORT Permit Number: OSP241207 PID Number: 018-401-37 Dwelling.- RE Single Family (SF) R with ADU El Duplex (D) El Two Single Family Project: 501 New El Upgrade Name Joshua & Rebekah Schroeder ABSORPTION FIELD El Deep Trench RN Wide Trench R Bed Ej Mound Site Address 13904 Schubert cir El Other Phone (907)764-1670 Number of Bedrooms Four(4) Soil Rating 1.2 JTotal depth from original grade 3.0 / 2.7 GPD/SF1 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade 2.5/2.2 Ft. Gravel depth beneath pipe 0.5 / 0.5 Ft. Subdivision Block Lot Dearmoun #2 2 8 Fill added above original grade 1.6/1.7 Ft. Gravel length 50 / 50 Ft. Township Range, Section Gravel width 5.0/5.0 [1 Ft. Beds: Number of Lines N/A Distance between lines N/A Ft. SEPARATION DISTANCES To Septic Tank Absorption Field Lift Station Holding Tank Sewer Total absorption area 500 Number of trenches Two(2) Dist. between trenches 6.0 From Line Ft2 Ft. Well > 194' > 196'* N/A N/A >25 TANK R) Septic El S.T.E.P. [0:1 Holding [I Other Manufacturer Infiltrator Capacity 1250 Gal. Surface Water >1 00' >100' N/A N/A Material Plastic Number of compartments Two(2) Lot Line >5' >10' N/A N/A NA Foundation >10' >10' N/A N/A IEA�ATON Capacity IManufacturer Remarks Trenches listed east / west Gal. -*Community well. See DEC waiver. Alarm location Ele r . tailed by Installer PIPE MATERIAL House to tank D3034 Tank Tank to D3034 Red Dog Masonry Drainfield D3034 CO/MT D3034 InspectorM. Jakubisin & J. Opheim BENCH MARK (Assumed elevation) 100 ft Inspdates: nd ection 15, 12/20/24 12/20/24 Location and description 2 Fop of Foundation @ S Wall 3rd 12/26/M 411 ON -SITE WATER AND WASTEWATER SECTION APPROVAL Engineer's Stamp F AQ kk� Conditional Approval: Date Aft� _4 Ame- . . . Septic SystemBenjanpSchiller 12592 Approved I Date .1./27/25 Aw X. PRO FES --Ww Note: this a approval does not include well permit requirements. I kmev UO/uLl ! 0) LOT 8 Benjamin Schiller CE 12592R E GISTEREDPROFE S S I O N A L E N GINEER 1"=40' CO - CLEANOUT 2CO - DOUBLE CLEANOUT FCO - FOUNDATION CLEANOUT FS - FLOW SPLITTER VALVE MH - MANHOLE MT - MONITORING TUBE SV - SEPTIC VENT TH - TEST HOLE LEGEND PERMIT # OSP231207 PID # 018-401-37 DEARMOUN #2, BLOCK 2 LOT 8 A B FCO 39.3 SV 55.0 MH 54.7 A B 2CO 58.5 FS 62.3 CO1 66.3 MT1 64.0 29.6 35.4 42.6 34.7 34.6 22.1 26.1 FEET 0 40 80 PLAN AS-BUILT 1/27/2026 2-BDRM HOME GARAGE W/ 1 BED ADU 10 ' U T I L I T Y E A S E M E N T DEARMOUN ROAD SCHUBERT CIRCLE 200' WELL RESERVE RADIUS TRACT A WELL RESERVE TH#2 FCO SV (2) NEW 50' LONG x 5' WIDE, 0.5' EFFECTIVE DEPTH ABSORPTION TRENCH 1250-GAL SEPTIC TANK W/ 20" MANWAY ALTERNATE SITE CAT III 25' LONG x 5' WIDE, 0.5 EFFECTIVE DEPTH ABSORPTION TRENCH 300 305 310 315 295 295 WATER SERVICE LINE TH#1 CO2 CO4 CO3 MT2 MT4 MT3 MH CO2 75.7 MT2 74.7 CO3 76.3 MT3 78.1 CO4 102.0 MT4 97.7 71.6 67.2 33.6 38.8 83.3 78.2 MT1 2CO CO1 FS CARPORT 6.1 CO5 CO5 00 30.147.1 C D C D 0 0 0 00 0 PROFILE AS-BUILT (NO SCALE) 95.7 92.0 96.6 100.3 FC O MH SV PERMIT # OSP231207 PID # 018-401-37 DEARMOUN #2, BLOCK 2 LOT 8 99.4 FINISH GRADE 50' DRAINFIELD ROCK MT 1 TH # 2 GROUNDWATER @ 89.8 11/20/24 94.8 95.3 CO 1 CO 2 82.3 94.8 95.3 97.8 ORIGINAL GRADE MT 2 2C O 95.4 Benjamin Schiller CE 12592 R E GISTEREDPROFE S S I O N A L E N GINEER 1/27/26 2" FOAM INSULATION 98.8 FINISH GRADE 50' DRAINFIELD ROCK MT 3 TH # 2 GROUNDWATER @ 89.1 11/20/24 94.4 94.9 CO 3 CO 4 81.6 94.4 94.9 97.1 ORIGINAL GRADE MT 4 2" FOAM INSULATION 1250 GAL PLASTIC SEPTIC TANK 2" FOAM INSULATION EAST TRENCH WEST TRENCH DEARMOUN ROAD DEARM O U N S U B D N O . 2 BLOC K 2 SCHU B E R T CIR Taylor L. Dosch No. 189892 R E GISTEREDPROFESSIO N A L L A N D S URVEYOR Page 1 of 3 February 13, 2026 Department of Environmental Conservation DIVISION OF ENVIRONMENTAL HEALTH Drinking Water Program 555 Cordova Street Anchorage, Alaska 99501 Main: 907.269.7656 Toll Free: 866.956.7656 Fax: 907.269.7650 dec.alaska.gov Joshua and Rebekah Schroeder File: DeArmoun II Owner PWSID: AK2211936 13900 Schubert Cir Class: Community Anchorage, AK 99516 Source: Groundwater jmsschroeder@hotmail.com DEC Project ID#: 19403 Re: DeArmoun II – B2L8 Septic System Improvements Separation Distance Waiver Dear Mr. Schroeder, This office received a submittal on February 3rd, 2026, from Ben Schiller, P.E., with FORGE Engineering requesting a Separation Distance Waiver for the DeArmoun II Block 2 Lot 8 Septic System Improvement project. This letter issues a Separation Distance Waiver for the requested reduction in the State’s minimum separation distance requirement between the source water well and septic system components as detailed in the submitted engineering plans and outlined below. Project Background This on-site wastewater disposal septic permit was installed in July of 2024 for the house located at 13900 Schubert Circle in Anchorage, AK and is shown in Figure 1. The original design of this residential septic system was designed outside of the 200-foot radii for the DeArmoun #2 community well. However, it was discovered during the record drawing process that the survey stakes were off and 2/3 of the septic tank is at 195-feet from the well and about 3.4-feet of one of the absorption trenches were installed within the 200-foot separation radius of the community well. The new septic tank is a 1250-gallon plastic tank with 20-inch manway from Infiltrator Water Technologies and 4-inch 304 schedule 80 PVC pipe was used (gravity system). Two absorption trenches were construction that were 50-foot long, 5-foot wide and 0.5-foot effective depth. Rigid insulation board was placed on top of both the septic tank and trenches. Each trench has two cleanouts and one monitoring pipe. The new septic system is at a lower elevation than the existing well and is sloped away from the well. The groundwater is approximately 90-feet below the ground surface and well is drilled to a total depth of 167-feet. A separation distance waiver was requested once this was discovered and the waiver is for: • 195 feet to new septic tank • 196 feet to northern absorption trench Septic System Improvements 2/13/2026 260213_DeArmoun B2L8 Septic System_211936_WA.docx Page 2 of 3 Figure 1: Constructed New Septic System at 13900 Schubert Cir in Anchorage AK. Separation Distance Waiver The separation distance waiver for encroachment of the source water well is approved based on the following design elements to maintain public safety: • Septic system is designed to slope away from the community well and is at a lower elevation • Septic system was tested for water tightness and had no leaks • Septic tank is plastic tank and has effective life span of 50 years • Vertical separation is approximately 80-feet from trenches to groundwater through silty sandy soils. • Shallow absorption trench with 2-inch rigid insulation board on top of drain field rock and 4-feet of cover Septic System Improvements 2/13/2026 260213_DeArmoun B2L8 Septic System_211936_WA.docx Page 3 of 3 Limitations and Appeal Process This waiver is limited to this project and its current site conditions. Any changes, constructed or natural, that affect the conditions to which this waiver was granted may void this waiver and the water or sewer may be required to be relocated to meet separation distance requirements. Approval of this waiver does not obligate the department to approve future waiver requests proposing the same design, is not an approval of omissions or oversights, and does not guarantee correctness of the functional design or waive the owner’s responsibility for continued compliance with state, federal, and local regulations. A person authorized under a provision of 18 AAC 15 may request an informal review of a contested decision by the Division Director in accordance with 18 AAC 15.185 and/or an adjudicatory hearing in accordance with 18 AAC 15.195 - 18 AAC 15.340. See DEC’s “Appeal a DEC Decision” web page https://dec.alaska.gov/commish/review-guidance/ for access to the required forms and guidance on the appeal process. Please provide a courtesy copy of the adjudicatory hearing request in an electronic format to the parties required to be served under 18 AAC 15.200. Requests must be submitted no later than the deadline specified in 18 AAC 15. If you have any questions regarding this waiver, please contact me at 907-269-8812 or email at kiana.eller@alaska.gov. Sincerely, Kiana Eller, P.E. Engineer I DEC Drinking Water Program Cc.: Jana Littlewood, Primary Operator, Jana_littlewood@awps.com Benjamin Schiller, P.E., FORGE Engineering, ben@forgecivil.com Elizabeth Nakanishi, DEC EPS III, elizabeth.nakanishi@alaska.gov Ana Sofía Pottellá Perez, DEC EPS, anasofia.pottellaperez@alaska.gov Fayzul Kabir, DEC WW Engineering Associate 1, Fayzul.kabir@alaska.gov MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 hftp://www.muni.org/onsite On -Site Wastewater Disposal System Permit Permit Number: OSP241207 Work Type: Septic Upgrade /!v( r+IqL Tax Code Number: 01840137000 Site Legal Address: DEARMOUN #2 BLK 2 LT 8 G:2935 Site Mailing Address: 13900 Schubert CIR, Anchorage Owner: SCHROEDER JOSHUA & REBEKAH Design Engineer: FORGE ENGINEERING This permit is for the construction of: 21 Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy Effective Date: Expiration Date: 7/30/2024 7/30/2025 Lot Size in Sq Ft: 29658 Total Bedrooms: .3-- ❑ Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Received By: —_ T" orl C, Date: _ Issued By: L Date: �2� UTE E E R I N G September 25, 2024 c Y PO BOX 240773 ANCHORAGE. AK 44524 522-7773 677-7766 (FAX) FORGECIVIL.COM MOA Development Services, On -Site Water & Wastewater Program 4700 Elmore Rd Anchorage, AK 99507 Subject: Dearmoun #2, Block 2 Lot 8 — NHN Schubert Circle Septic system design Dear On -Site Services Engineer: The owner of the above lot intends to build a 4-bedroom home on the property, so we are submitting this permit application for the construction of a septic system. The attached site plan identifies the location of the home as well as the existing community well reserve, septic location and alternate site. The ground surface on the lot slopes steeply on the southeast side of the lot, but the slopes even out on the southwest side and are much milder. It is in that flatter area that the new septic system is located. There are no slopes greater than 25% within 50 feet downslope of either the primary or alternate site. Contours are shown on the site plan showing the grade and direction of flow. Stormwater drainage will not impact this septic system. The new trench will be constructed parallel to the slope as much as possible. Wells on this and adjacent lots are shown. No conflicts exist between this proposed system and any other well or septic system, whether on this lot or adjacent lots. The new system will be a minimum of 200' from the community well, more than 100' from surface water, and more than 5' away from the septic tank. The alternate site is located more than 6' away. Please refer to the attached test hole log, plan and profile pages for the septic design. If this design is followed, there will be no adverse impacts to adjacent properties. Sincerely, Benjamin Schiller, PE MUNICIPALITY OF Community Development Department Development Services Division On -Site Water & Wastewater Program Phone: 907-343-7904 Fax: 907-343-7997 ON -SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 018-401-37 Property owner(s) Joshua & Rebekah Schroeder Mailing address 4052 W 89th Court Site address NHN Schubert Circle Day phone (907)764-1670 Legal description (Sub'd., Block & Lot) Dearmoun #2 Block 2 Lot 8 Legal description (Township, Range & Section) Lot Size 29,658 —Sq. Ft. Number of Bedrooms 3 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (Z all that apply) Absorption Field FX� Initial RX Single Family (SF) (w/wo ADU) Septic Tank FX_1 Upgrade 1-1 Duplex (D) ❑ Holding Tank R Renewal Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) $ Permit/Rush Fees: Date of Payment: Receipt Number: Permit No. 05P?-c-t1207 Waiver Fees: Date of Payment: Receipt Number: Waiver No. Permit App_-'- : - :-'.,:c , t DEARMOU N #2, BLOCK 2 LOT 8 TRACT A 1 j WELL RESERVE SCHUBERT CIRCLE �t � O WATER SERVICE LINE i ROPOSED ;DRM HOME LroT" — — — — — — — — — — — — — — FCO Lu 200' WELL RESERVE RADIUS 2C0 L TH�#1 LOT F , TH# M p ' CO ----- --------------- ALTERNATE SITE CAT III -- 25' LONG x 5' WIDE, 0.5 (2) 50' LONG x 5' WIDE, 0.5' EFFECTIVE DEPTH EFFECTIVE DEPTH ABSORPTION ABSORPTION TRENCH TRENCH DEARIVIOLIN ROAD '.. ENGiNEE0.1NG LEGEND Q" •""'`�1�, CO - CLEANOUT * 49 TM .*fr SEPTIC PLAN 2CO - DOUBLE CLEANOUT Ay ,,, •i^!,,,,,,� FCO- FOUNDATIONCLEANOUT f � ,� —, • FS - FLOW SPLITTER VALVE f MH - MANHOLE Benja i Schiller �� �F'• CE 2592 ���i 0 40 80 MT - MONITORING TUBE m c�Jl •. 11no2a ,.••(�� FEET ti�iF�PROFESSION��.� SV - SEPTIC VENT 1N_ — TH -TEST HOLE DEARMOUN #2, BLOCK 2 LOT 8 DESIGN FACTORS: SYSTEM REQUIREMENTS: 600 GPD PEAK FLOW 5' WIDE TRENCH SYSTEM PERK RATE: 4 MIN/IN 1250—GAL SEPTIC TANK Cat a APPLICATION RATE: 1.2 GPD/SF 600 GPD / 1.2 GPD/SF / 5' WIDE * 1.00 RED FACTOR [0.5' DEEP] = 100 LF TRENCH REQUIRED (2x 50 LF SPECIFIED) BOTTOM OF TRENCH: T BELOW GRADE FLOW LINE ELEVATION: 2'6" BELOW GRADE nnrwnr ADDITIONAL FILL TO FOR SETTLEMENT 2" FOAM INSULATION GEOTEXTILE FABRIC 4" PERFORATED PVC (HOLES DOWN) DRAINFIELD ROCK TYPICAL TRENCH SECTION (NO SCALE) NOTES: 1. GRADE AREA OVER TRENCH TO DRAIN AWAY 2. PROVIDE S OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2' WITH 2" OF INSULATION 3. CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY E N G I NffRI oF, • ' • • Benja • . Schiller �,�Fc •. CE 1259211/21/2024 �tj��PROfESSIONP��.► � LEGAL DESCRIPTION: PERFORMED FOR: DATE: PARCEL ID#: SOILS LOG AND PERCOLATION TEST 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 DEPTH (feet) TEST HOLE 1 DATE READING START TIME NET TIME (minutes) DEPTH to WATER NET DROP PERCOLATION RATE: (MIN/INCH) (inches)(inches) DATE OF MONITORING WAS WATER ENCOUNTERED? DEPTH TO WATER AFTER MONITORING IF YES @ WHAT DEPTH? 0.12 1/17/24 1 2 3 4 5 6GM (SILTY SANDY GRAVEL) Professional Engineers Stamp: NO DEARMOUN #2 BLOCK 2 LOT 8 1/17/2024 018-401-37 RED DOG MASONRY 10:14 1 0 16 10:15 10:15 10:17 10:18 10:19 2' OB 0:25 Benjamin Schiller CE 12592REGISTEREDPROFESSION A L E N GINEER PERC TEST LOCATION TECHNICIAN: J.OPHEIM & M.JAKUBISIN 7 0 16 - NONE 1/24/24 COMMENTS: SITE PLAN 6 0 16 USCS SOIL CLASSIFICATION WAS VISUALLY DETERMINED 1/17/24 1 0 160:31 7 0 16 6 0 16 1 0 160:34 7 0 16 6 0 16 1 0 160:38 7 0 16 6 0 16 1 0 160:38 7 0 16 6 0 16 1 0 160:42 7 0 16 6 0 16 1 0 160:43 7 0 16 6 0 167 10:20 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP241207, Curtis Townsend, 07/30/24 SOILS LOG AND PERCOLATION TEST /*:•ATM �* E N G 1 N E E R I N G Benja - Schiller ' • / r, �'F•• CE 12592 LEGAL DESCRIPTION: DEARMOUN #2 BLOCK 2 LOT 8 IFgFOPRO113/24 PERFORMED FOR: RED DOG MASONRY \.o.\\"``� DATE: 11 / 13/2024 PARCEL ID#: 018-401-37 Professional Engineers Stamp: DEPTH TEST HOLE 2� C- (feet) 1'OB 1 2 GW (WELL GRADED GRAVEL) PERC TEST LOCATION 4 5 6 7 GM (SILTY SANDY GRAVEL) 8 -� PERCOLATION RATE: 4.0 (MIN/INCH) 9 1 SITE PLAN 11 12 13 14 15 16 17 18 19 NO WAS WATER ENCOUNTERED? - IF YES rd WHAT DEPTH? 8.0 DEPTH TO WATER AFTER MONITORING 11 /20/24 DATE OF MONITORING TECHNICIAN: M . JAK UB I S I N COMMENTS: USCS SOIL CLASSIFICATION WAS VISUALLY DETERMINED DATE READING START TIME NET TIME (MINUTES) WgTER � (INCHES) NET DROP (INCHES) 11/13 1 3:42 26:00 11s 716 616 2 4:08 10:00 11s 41s 31s 3 4:19 10:00 11s 4 106 316 4 4:29 10:00 1 1s 3 is 2 is 5 4:39 10:00 11s 31s 21s 6 4:50 10:00 11s 316 21s