Loading...
HomeMy WebLinkAboutT15N R1W SEC 5 LT 5215N RIW SEC 5 Lot 52 #051-032-32 MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Wastewater Disposal System Permit Permit Number: OSP241215 Work Type: Septic Initial Tax Code Number: 05103232000 Site Legal Address: T15N R1 W SEC 5 LT 52 G:1557 Site Mailing Address: 22043 STOLTZE DR, Chugiak Owner: STOLTZE BILL (DONALD WM) Design Engineer: NORTH RIM ENGINEERING This permit is for the construction of: Effective Date: Expiration Date Lot Size in Sq Ft: Total Bedrooms: l)elr<nCrlirnt 7/31/2024 7/31/2025 57934 P Disposal Field P Septic Tank ❑ Holding Tank ❑ Privy P Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Special Provisions: 1. The grid map appears to show the centerline of the creek. The as -built survey submitted with the Inspection Report is to have the creek surveyed in to confirm that the well is a minimum of 50' away. 2. Perforated distribution pipe used in a subsurface disposal field shall be laid level and bedded with drainrock extending a minimum of two inches above the top of the distribution pipe, and level across the entire width of the drainfield. -Resefved : 55tAeA -+0 1%o,-ih R,In, Date: Issued By: Date: _' Z` — 4 MUNICIPALITY OF ANCHORAGE .......... ........... Development Services Department Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 ON-SITE SEPTIC/WELL PERMIT APPLICATION Parcel I.D. 05103232000 Property owner(s) STOLTZE BILL Day phone 907 632 4478 Mailing address 22043 STOLTZE DR Site address same Legal description (Sub'd., Block & Lot) T1 5N R1 W SEC 5LT 52 Legal description (Township, Range & Section) Lot Size 57,934 Sq. Ft. Number of Bedrooms 4 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (N all that apply) Absorption Field Fxj Initial RX Single Family (SF) RX (w/wo ADU) Septic Tank RX Upgrade R Duplex (D) ❑ Holding Tank R Renewal R Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well F71 Water Storage ❑ THIS APPLICATION INCLUDES A WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) k_9 �_ Permit/Rush Fees:. Waiver Fees: Date of Payment: Date of Payment: Receipt Number: Permit No. C Receipt Number: Waiver No. GADevelopment Services\Building Safety\On Site Water and WastewaterTormsUient FormsTermit Application.doc W Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP241215, Deb Wockenfuss, 07/31/24 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP241215, Deb Wockenfuss, 07/31/24 SteveEng.com T15N R1W Sec5 L52 SPECIFICATIONS & DESIGN GUIDELINES Wastewater System Sizing: This is a proposed 4-bedroom, single family home. This is a partially developed subdivision. A new trench is planned + new 1500 gallon Steel STEP tank. No adverse impacts are expected from trench/tank construction. No conflicts to the other lots will take place by this septic system construction. A new soil test reveals SW w/gravel. An application rate of 1.2 GPD/FT². Trench Length = 500 FT²/5 x 0.87 = 87 trench, 5 -wide, 1 effective depth. A new 1500 gallon STEP Steel tank will be installed. Easements depicted in the area, private water wells serve the area, with a proposed well site. Specification Requirements: All components and work must comply with the Municipality of Anchorage Specifications (AMC) & State of Alaska Drinking Water Regulations and Wastewater Regulations. New 1500 Gallon Steel STEP tank. MOA-Approved. MOA-Spec Material Under Tank. 10 minimum between the tank/trench to house. 10 to property lines, 3 of cover or insulation is required for trench; 2 Minimum thickness for insulation can substitute for 1 cover. Tank & solid pipe must be set on well compacted, stable soil. 4 inch diameter cleanouts with airtight caps are required 1 to 4 from foundation wall, prior to any 90 degree bend in 4 inch line, in each tank compartment, and two adjacent opposing cleanouts between the tank and the absorption field, not more than 10 from the tank positioned to provide cleanout access towards the tank and towards the absorption field. All cleanouts must extend to at least ground level. In solid pipe runs, ASTM D-3034 may be used in lieu of cast iron. Trench to be placed level, minimum of 4 to groundwater, 6 to bedrock. Drain rock to be ½ to 2 screened, distributed uniformly throughout the trench. Force main to be 1.25 Schedule 40 PVC or equal. Distribution pipe to be 1.25 Schedule 40 PVC w/ 1/8 orifice @ 18 on-center. Silt barrier (filter fabric) to be installed above the drain rock. Smeared trench sides must be raked or scarified before drain rock placement. The finish grade must be mounded to promote drainage away from trench. Insulation must be placed over any pipe installed under driveways or parking areas. Approved pipe materials include cast iron, PVC ASTM D3034, PVC ASTM F789, ABS ASTM D2661, Sewer Service Line is minimum 2% slope. Septic Tank to be pumped every two years or when required. Insulation board to be extruded direct burial polystyrene (Dow Styrofoam HI/equal) Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP241215, Deb Wockenfuss, 07/31/24 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP241215, Deb Wockenfuss, 07/31/24