Municipality of Anchorage
On -Site Water and Wastewater Section - (907) 343-7904 Page 1 of 1
ON-SITE WASTEWATER INSPECTION REPORT
Permit Number: OSP241273
PID Number: 020-044-19
Dwelling: F01 Single Family (SF)
R with ADU F71 Duplex (D) n Two Single Family Project: X New n Upgrade
Name
Mission Hills, LLC.
ABSORPTION FIELD
Deep Trench n Wide Trench El Bed n Mound
Site Address
6998 Avalanche Cir.
El Other
Phone
of Bedrooms
Soil Rating
Total depth from original grade
6
1.2 GPD/SF
10.0 Ft.
LEGAL DESCRIPTION
Depth to pipe invert from original grade
4.0 Ft.
Gravel depth beneath pipe
6.0 Ft.
Subdivision
Block Lot
Spruce Terraces
14
Fill added above original grade
0-2.4 Ft.
Gravel length
70 Ft.
Township Range Section
Gravel width
2.5 Ft.
Beds: Number of Lines
n/a
Distance between lines
n/a Ft.
SEPARATION
DISTANCES
To
Septic
AbsorptionLift
I Station
Holding Sewer
Total absorption area
Number of trenches
Dist. between trenches
From
Tank
Field
Tank Line
840 Ft2
1
n/a Ft.
Well
100'+
100'+
NA
NA 25'+
TANK X Septic El S.T.E.P. El Holding El Other
Manufacturer
Anchorage Tank
Capacity
2500 Gal.
Surface Water
100'+
100'+
NA
NA
Material
Steel (Epoxy Coated)
Number of compartments
2
Lot Line
10'+
10'+
NA
NA NA
Foundation
10'+
10'+
NA
NA 1
LIFT STATION
Manufacturer
Capacity
Gal.
Remarks * Lot served by community well
Alarm location
Electrical installed by
PIPE MATERIAL House to tank D3034 Tank to D3034
drainfield
Installer
Pomraning Excavation,
LLC,
Drainfield D3034 CO/MT D3034
Inspector PES
BENCH MARK (Assumed elevation) 104.6 ft
ection is, 07/17/25
Inspdates:
07/18/25
Location and description
Yd 07/21/25
Z"
41" 07/30/25
1 See Site Plan 'BM'- Threshold Sliding Back Door
ON-SITE WATER AND WASTEWATER SECTION APPROVAL
Engineer's Stamp
0Ak
OF A�.q
Conditional Approval:
Date
-
-- -----------
49 T H
I .... .. . ....
even R. Pannone fw
Septic Systeoe12
CE 8149
Approved
Dat
"'--
PI?OFESS6�
Xte: this approval does not include well permit requirements.
(Kev u5/ 7 )
SHANGRI-LA SUBDIVISION
Av
a
l
a
n
c
h
e
C
i
r
c
l
e
PA
N
N
O
N
E
E
N
G
S
V
C
,
L
L
C
(
C
.
I
.
1
0
8
8
)
LJ
C
RE
C
O
R
D
D
R
A
W
I
N
G
S
SP
R
U
C
E
T
E
R
R
A
C
E
S
L
O
T
1
4
CL
I
E
N
T
:
S
P
I
N
E
L
L
H
O
M
E
S
,
I
N
C
.
SI
T
E
:
6
9
9
8
A
V
A
L
A
N
C
H
E
C
I
R
C
L
E
AN
C
H
O
R
A
G
E
,
A
K
9
9
5
1
6
08
/
0
1
/
2
0
2
5
02
0
-
0
4
4
-
1
9
OS
P
2
4
1
2
7
3
AC
P
RE
V
1
:
0
8
/
2
0
/
2
0
2
5
08
/
0
1
/
2
0
2
5
1"
=
6
0
'
1
O
F
2
PROFILE
SCALE: NTS
2500gal EPOXY COATED
STEEL SEPTIC TANK
PA
N
N
O
N
E
E
N
G
S
V
C
,
L
L
C
(
C
.
I
.
1
0
8
8
)
LJ
C
RE
C
O
R
D
D
R
A
W
I
N
G
S
SP
R
U
C
E
T
E
R
R
A
C
E
S
L
O
T
1
4
CL
I
E
N
T
:
S
P
I
N
E
L
L
H
O
M
E
S
,
I
N
C
.
SI
T
E
:
6
9
9
8
A
V
A
L
A
N
C
H
E
C
I
R
C
L
E
AN
C
H
O
R
A
G
E
,
A
K
9
9
5
1
6
08
/
0
1
/
2
0
2
5
02
0
-
0
4
4
-
1
9
OS
P
2
4
1
2
7
3
AC
P
RE
V
1
:
0
8
/
2
0
/
2
0
2
5
08
/
0
1
/
2
0
2
5
NT
S
2
O
F
2
MUNICIPALITY'011F ANCHORAGE
DEVELOPMENT SERVICES DEPARTMENT( e, 3 4 907-343-7904
1 W, , ` A"
On -Site Water and Wastewater Section
J,
Fax: 343-7997
www.muni.org/onsite
PERMIT #241273
PID 020-044-19
SUED Spruce Terraces
CONTACT PERSON Steven Pannone
CHANGE ORDER
TRACT BLOCK LOT 14
PHONE (907) 745-8200
PLEASE GIVE A DESCRIPTION OF THE CHANGE The location of the proposed drain field was modified during
construction based on the field -verified location of the previously installed test hole monitoring tube (TH-14), which
was exposed and identified on site. To maintain consistency with the approved soil test data and verified site conditions, the
drain field was relocated to correspond with the field verified location of the existing test hole. Additionally, the original configuration
of two 35 -foot long trenches was revised to a single 70 -foot long trench at the proposal and recommendation of the system installer.
CUSTOMER SIGNATURE Date: 0e1c,112_o2_6-
1#14919)(3111a•
On -Site
Reviewer:
Comments
Issued
(date)
Review
Time
(hours)
APPROVED (date)
TOTAL HOURS
HOURLY RATE $145
TOTAL TO BE PAID
DATE PAID
RECEIPT #
040.002
Date: November 14, 2024
Client: Pannone Engineering Services, Name
Project: Spruce Terracres Lot 14
Anchorage, Alaska
Crowther Associates
Particle Size Distribution Table
(percent passing subject sieve size)
Sample Source
--
Moisture
Content
6.6%
Sieve Size
Percent Finer
Percent Finer
Percent Finer
Percent Finer
3 inch
100
1-1/2 inch
100
3/4 inch
89
#4
66
#10
52
y
#40
22
#100
11
#200
10
0.02 mm
xx
Classification
Gravelly Sand
with Silt (SM)
Invoice 230
1632 Bellevue Circle /Anchorage, Alaska 99515
Telephone (907) 349-2198 /E mail: 907crowther@gmail.com
MUNICIPALITY OF ANCHORAGE
On -Site Water & Wastewater Program
PO Box 196650 4700 Elmore Road
Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997
hftp://www.muni.org/onsite
On -Site Wastewater Disposal System Permit
Permit Number: OSP241273
Work Type: Septic Initial
Tax Code Number: 02004419000
Site Legal Address: SPRUCE TERRACES LOT 14 G:3239
Site Mailing Address: 6998 AVALANCHE CIR, Anchorage
Owner: MISSION HILLS LLC
Design Engineer: PANNONE ENGINEERING SERVICES
This permit is for the construction of:
Effective Date
Expiration Date:
Lot Size in Sq Ft
Total Bedrooms:
r�
De partIII cnt
9/5/2024
9/5/2025
56313
Q Disposal Field 0 Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
Special Provisions:
• The engineer is to collect a soil sample for sieve analysis to confirm USCS classification of soil. Submit a
change order if the soil requires a sand liner.
r
Received By: �" i- Date:
�
Issued By: Date:
y �, '-2L
N.
MUNICIPALITY OF ANCHORAGE
Qa A
Community Development Department Phone: 907-343-7904
Development Services Division Fax: 907-343-7997
On -Site Water & Wastewater Program
ON -SITE SEWER/WELL PERMIT APPLICATION
Parcel I.D. 020-044-19
Property owner(s) Mission Hills LLC
Mailing address
Site address NSN Avalanche Circle
Day phone
Legal description (Sub'd., Block & Lot) Spruce Terraces, Lot
Legal description (Township, Range & Section)
Lot Size - 56,313 —Sq. Ft. Number of Bedrooms 6
APPLICATION IS FOR:
APPLICATION IS AN:
TYPE OF DWELLING:
(Z all that apply)
Absorption Field
FRI
Initial RX
Single Family (SF)
(w/wo ADU)
Septic Tank
19
Upgrade R
Duplex (D) ❑
Holding Tank
El
Renewal ❑
Multiple Dwellings ❑
Privy
❑
(SF and/or D)
Private Well
❑
Water Storage
❑
THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit/Rush Fees:
Date of Payment:
Receipt Number:
Permit No.
Waiver Fees:
Date of Payment:
Receipt Number:
Waiver No.
Permit App_-'- '. I
Pannone Engineering Services LLC
Steven R. Pannone, Principal
Registered Professional Engineer
E‐mail: steve@panengak.com
Mailing: P.O.Box 1807, Palmer, AK 99645
Telephone: (907) 745‐8200 FAX: (907) 745‐8201
Municipality of Anchorage
Development Services Department
On‐Site Water & Wastewater Program
4700 Elmore Road
Anchorage, Alaska
Subject: Spruce Terraces, Lot 14
Septic System Permit Request
This is a design narrative for a permit to install an initial septic system on the subject property. The proposed system
will serve a proposed six‐bedroom (6br) house. This lot and surrounding lots within Spruce Terraces are served by a
community water system. The lots to the south are served by private wells. There are no wells within 200’ of the
proposed septic system.
1. Soils:
A test hole was performed in the vicinity of the proposed system on this lot by Pannone Engineering Services, LLC on
10/14/2020. Groundwater was not observed during the excavation of the test hole, and bedrock was not
encountered. Groundwater was not observed in the test hole monitor tube after 7‐daysor at any time since. Based
on the results of the percolation test and overall soils appearance an application rate of 1.2 gpd/SF was used for the
design of a conventional wastewater treatment system in the area of the test hole. The soils encountered and sieve
tested so far in the subdivision have conformed to a sand classification with <50% passing a #4 sieve (including
neighboring L13). A sieve analysis will be performed on the soil in the area of the drain field to verify the in‐situ
sand, and a change order will be submitted if the soil is found to require a sand filter.
2. Soil Absorption System Design.
a. See Sheet 1 of the design package.
3. Surface Water:
There is no surface water within 100 feet of the proposed septic tank and drain field.
4. Topography:
See attached site plan for area topography. There are no steep slopes in the vicinity of the drain field.
5. Drawing Markings: The Drawings are marked “For MOA Review Only”. When written notification that the
review is complete and no further comments are received from MoA On‐Site Department, the note will be removed
and “For Construction” drawings will be issued.
The proposed installation will not affect the future development of this or the surrounding lots.
If you have any questions or concerns, please contact me at (907) 745‐8200.
Sincerely,
SRP
Steven R. Pannone, P.E. F. ASCE
Owner/Civil Engineer
2 August 2024
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP241273, Curtis Townsend, 09/05/24
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP241273, Curtis Townsend, 09/05/24
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP241273, Curtis Townsend, 09/05/24
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP241273, Curtis Townsend, 09/05/24
MUNICIPALITY OF ANCHORAGE
Development Services Department Phone: (907)343-7904
On -Site Water & Wastewater Section Fax: (907)343-7997
Certificate of On -Site Systems Approval
OSC251348
Parcel ID 020 -044-19 Expiration Date:
Legal description SPRUCE TERRACES LOT 14
site address 6998 AVALANCHE CIR
Current property owner(s) MISSION HILLS LLC
X The On-site system(s) is/are approved for 6 bedrooms
W
7/21/2026
Conditional approval for bedrooms, with the following stipulations:
Comments or conditions:
No comments
Original Certificate Date:
8/20/2025
This Certif' to of On -Site Systems Approval (COSA) is intended to demonstrate the subject
syste is/are in substantial compliance with municipal code. The Municipality of Anchorage,
De opment Service Department (DSD) issues COSAs based upon representations provided by an
in ependent professional engineer. The Municipality of Anchorage is not responsible for errors or
omissions in the professional engineer's submittal.
ATTACHMENTS:
COSA Checklist X Well Flow Advisory
Absorption Field Advisory Nitrate Advisory
Tank Age Advisory Arsenic Advisory
Other
MUNICIPALITY
MENEEMI
a�_ /
Development Services Department Abu Phone: 907-343-7904
On -Site Water & Wastewater Section Fax: 907-343-7997
Certificate of On -Site Systems Approval Application
1. GENERAL INFORMATION
Parcel I.D. 020-044-19
Complete legal description Spruce Terraces Lot 14
Location (site address) 6998 Avalanche Circle
Current property owner(s) Mission Hills, LLC.
2. ON-SITE SYSTEMS SIZED FOR 6 BEDROOMS
Day phone
3. TYPE OF WATER SUPPLY: ❑ Private Well serving # dwelling units
❑ Other Non-public well as regulated by MOA ❑ Water Storage
X Community Well or Public
4. TYPE OF WASTEWATER DISPOSAL: ❑■ Private Septic ❑ Private Septic serving 2 dwelling units
❑ Holding Tank ❑ Community Septic or Public Sewer
5. SEPTIC TANK: R Steel ❑ Plastic ❑ Concrete ❑ Fiberglass
Age <1 - See advisory if steel or fiberglass older than 20 years
6. ABSORPTION FIELD: ❑ AWWTS ❑ Bed FE� Deep Trench ❑ Wide Trench ❑ Seepage Pit
Waiver request for: Distance:
Expedited review requested: ❑
By applying for this entitlement, this property is subject to inspection by municipal On-site staff
to verify the accuracy of the information provided.
COSA Fee $ 7
Date of Payment V7/2S
COSA # 0505INK
Waiver Fee $
Date of Payment
Waiver #
COSA App1ication_Apr2025.doc
COSA Checklist_May2025.docx
COSA Checklist
Legal Description: Parcel ID:
If more than 1 well and/or septic system on lot, provide separate checklist. Structure served by this system ____
A. WELL DATA
Well log is filed with Onsite (or attached)
Date drilled Total depth ft
Cased to ft
Sanitary seal is functioning correctly
Wires are properly protected
Casing height (above ground) in.
Date of flow test for COSA
Static water level at beginning of test ft.
Well production at time of test gpm
Water storage tank volume gallons
Well disinfected for coliform test? Yes No
Coliform bacteria is Negative
Nitrate mg/L Nitrate less than MRL (ND)
Arsenic ug/L Arsenic less than MRL (ND)
Collected by
Date
Comments __________________________________________________________________________________
B. TANK DATA
Measured operating fluid level in septic tank
Date of pumping
Required maintenance completed, if AWWTS
Comments:
C. LIFT STATION
Required maintenance completed
Age of lift station years
Lift station material
Comments:
D.DISPOSAL FIELD DATA
Which system tested (date installed)
ALL standpipes present per record drawing
Total measured depth from grade ft (max)
Measured depth to pipe invert from grade ft (min)
N/A – pressurized field.
Per record drawings, field is insulated.
Monitor tubes go to bottom of effective.
If not, state depth into effective
Presoaked required if
(Required if house vacant or field not used for more
than 30 days prior to date of test)
Gallons introduced gallons date
Any rejuvenation treatment (past 12 months)
If yes, enter date
Adequacy test date
Results Pass
Fluid depth prior to test in
Water added gal
New fluid depth in
Elapsed time min
Final fluid depth in
Absorption rate gpd
FIELD STATUS – POST RECOVERY
Effective depth (per record drawings) in
Effective depth used in
Effective depth remaining in
Comments/Deficiencies:
E. SEPARATION DISTANCES
From Well on Lot to: (Please enter distances if less than required)
Septic Tank/Lift Station on Lot > 100’
Yes if No ft
Neighboring Tank > 100’ Yes if No ft
Disposal Field on Lot > 100’ Yes if No ft
Neighboring Disposal Fields > 100’
Yes if No ft
Sewer Line/Main > 100’ Yes if No ft
Sewer Manhole/Cleanout > 100’
Yes if No ft
Sewer Service/Septic Line > 25’ Yes if No ft
Holding Tank > 100’ Yes if No ft
Animal Containment > 50’ Yes if No ft
Manure/Animal Excreta Storage > 100’
Yes if No ft
N/A – Served by Community Well (not on lot) or Public Water
From Septic/Holding Tank and Disposal Field(s) on Lot to: (Please enter distances if less than required)
Tank to Foundation > 10’ Yes if No ft
Field to Foundation > 10’ Yes if No ft
Tank to Property Line > 5’ Yes if No ft
Field to Property Line > 10’ Yes if No ft
Water Main/Service Line > 10’ Yes if No ft
Surface Water > 100’ Yes if No ft
Wells on Adjacent Lots:
Wells > 100’ Yes if No ft
Community Wells > 200’ Yes if No ft
If tank or field is under driveway comment below
F.ENGINEER’S COMMENTS
G.CERTIFICATION & STATEMENT OF INSPECTION BY ENGINEER
Phone Name of Firm
Engineer’s Printed Name
COSA Checklist_May2025.docx
Date
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation,
based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines, indicates that the on-site
water supply and/or wastewater disposal system appears to comply with applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation, unless noted otherwise.
In conducting an adequacy test, I attempt to provide a thorough, conscientious
engineering analysis of the system in accordance with ADEC & MOA guidelines and
regulations. The reported results describe the performance of the system under the
conditions encountered at the time of the test, and separation distances measured to
readily identifiable features. The operational life of all wells and septic systems depend
on the local soil condition, ground water levels that may fluctuate during the years, and
the water usage of the people served by the system. These conditions are outside the
control of the evaluator of this system. All systems eventually fail, and satisfactory test
results do not guarantee future performance if the system, nor do they guarantee that
there are no hidden defects of encroachments. Therefore, we cannot provide any
warranty of future performance, nor can we estimate the remaining life of the system.
The content of this report is for the sole benefit of the owner listed above.
AsBuilt