Loading...
HomeMy WebLinkAboutSPRUCE TERRACES LOT 19SPRUCE TERRACES Lot 19 Municipality of Anchorage On -Site Water and Wastewater Section - (907) 343-7904 Page 1 of 1 ON -SITE WASTEWATER INSPECTION REPORT Permit Number: OSP241212 PID Number: 020-044-24 Dwelling: RN Single Family (SF) FE with ADU n Duplex (D) F] Two Single Family Project: nN New El Upgrade Name Mission Hills, LLC. ABSORPTION FIELD ME Deep Trench [:1 Wide Trench R Bed El Mound Site Address 6937 Avalanche Circle El Other Phone of Bedrooms Soil Rating Total depth from original grade 5 1.2 GPD/SF 13.0 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade 5.0 Ft. Gravel depth beneath pipe 8.0 Ft. Subdivision Block Lot Spruce Terraces 19 Fill added above original grade Ft. Gravel length 50.0 Ft. Township Range Section Gravel width 2.5 Ft, Beds: Number of Lines n/a Distance between lines n/a Ft. SEPARATION DISTANCES To Septic Absorption i Lift Station Holding i Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Tank Line 800 Ftz 1 n/a Ft. Well NA NA NA NA 25'+ TANK 9 Septic [I S.T.E.P. [I Holding El Other Manufacturer Greer Capacity 1500 Gal. Surface Water 100'+ 100'+ NA NA Material Number of compartments Lot Line 5+ 10'+ 1 NA NA NA HDPE (Deep Burial) 2 Foundation 10'+ 10'+ NA NA LIFT STATION Manufacturer Capacity Remarks Gal. Alarm location Electrical installed by PIPE MATERIAL House to tank D3034 rank to D3034 drainfield Installer Pomraning Excavation, LLC. Drainfield D3034 CO/MT D3034 Inspector PES BENCH MARK (Assumed elevation) 100.0 ft ection im 06/05/25 Inspdates: 06/06/25 Location and description 3rd 06/06/25 2' 4 1h 07/03/25 Bottom of South Deck Beam ON -SITE WATER AND WASTEWATER SECTION APPROVAL Engineer's Stamp OF AL�'s��� Conditional Approval: Date 49 TH F S-t-e,v-e-n. ........ne.... Panno Septic System Approved Date -7/5 v2o, E 8 149 111k, ik"k I . V Note: this approval does not include well permit requirements. Rev 05/02/18) Av a l a n c h e C i r c l e 1500 GAL GREER POLY TANK PROFILE SCALE: NTS PA N N O N E E N G S V C , L L C ( C . I . 1 0 8 8 ) LJ C RE C O R D D R A W I N G S SP R U C E T E R R A C E S L O T 1 9 CL I E N T : S P I N E L L H O M E S , I N C . SI T E : 6 9 3 5 A V A L A N C H E C I R C L E AN C H O R A G E , A K 9 9 5 1 6 07 / 2 1 / 2 0 2 5 02 0 - 0 4 4 - 2 4 OS P 2 4 1 2 1 2 AC P 07 / 2 1 / 2 0 2 5 1" = 6 0 ' 1 O F 1 AsBuilt 7/21/25 Feet 0 50 100 MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 hftp://www.muni.org/onsite On -Site Wastewater Disposal System Permit Permit Number: OSP241212 Work Type: Septic Initial Tax Code Number: 02004424000 Site Legal Address: SPRUCE TERRACES LOT 19 G:3239 Site Mailing Address: 6937 AVALANCHE CIR, ADU, Anchorage Owner: MISSION HILLS LLC Design Engineer: PANNONE ENGINEERING SERVICES This permit is for the construction of: Effective Date: Expiration Date Lot Size in Sq Ft: Total Bedrooms: 9/18/2024 9/18/2025 55417 Q Disposal Field 0 Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Received By: A— Date: r Issued By: Date: / ? L MUNICIPALITY OF ANCHORAGE Community Development Department Phone:907-343-7904 Development Services Division Fax: 907-343-7997 On -Site Water & Wastewater Program ON -SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 020-044-24 Property owner(s) Mission Hills LLC Day phone Mailing address Site address NSN Avalanche Circle Legal description (Sub'd., Block & Lot) Spruce Terraces, Lot 19 Legal description (Township, Range & Section) Lot Size. 55,417 —Sq. Ft. Number of Bedrooms 5 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (Z all that apply) Absorption Field FX� Initial EX-1 Single Family (SF) (w/wo ADU) Septic Tank FRI Upgrade R Duplex (D) ❑ Holding Tank ❑ Renewal Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. Szp (Signature of property owner or authorized agent) Permit/Rush Fees: 9 Date of Payment: Receipt Number: Permit No. Waiver Fees: Date of Payment: Receipt Number: Waiver No. Permit App_-'- '. � Pannone Engineering Services LLC Steven R. Pannone, Principal Registered Professional Engineer E‐mail: steve@panengak.com Mailing: P.O.Box 1807, Palmer, AK 99645 Telephone: (907) 745‐8200   FAX: (907) 745‐8201 Municipality of Anchorage Development Services Department On‐Site Water & Wastewater Program 4700 Elmore Road Anchorage, Alaska Subject:   Spruce Terraces, Lot 19          Septic System Permit Request This is a design narrative for a permit to install an initial septic system on the subject property. The proposed system will serve a proposed three‐bedroom (3br) house and one‐bedroom (1br) ADU. Per the owners request the system will be sized for five bedrooms. This lot and surrounding lots are served by a community water system.  There are no wells within 200’ of the proposed septic system. 1. Soils: A test hole was performed in the vicinity of the proposed system on this lot by Pannone Engineering Services, LLC on 10/14/2020. Groundwater was not observed during the excavation of the test hole, and bedrock was not encountered. Groundwater was not observed in the test hole monitor tube after 7‐daysor at any time since. Based on the results of the percolation test and overall soils appearance an application rate of 1.2 gpd/SF was used for the design of a conventional wastewater treatment system in the area of the test hole.   A sieve analysis was performed on the soil in the area of the drain field to verify the in‐situ sand.  See attached results. 2. Soil Absorption System Design. a. See Sheet 1 of the design package. 3. Surface Water: There is no surface water within 100 feet of the proposed septic tank and drain field. 4. Topography: See attached site plan for area topography. There are no steep slopes in the vicinity of the drain field. 5. Drawing Markings: The Drawings are marked “For MOA Review Only”. When written notification that the review is complete and no further comments are received from MoA On‐Site Department, the note will be removed and “For Construction” drawings will be issued. The proposed installation will not affect the future development of this or the surrounding lots. If you have any questions or concerns, please contact me at (907) 745‐8200. Sincerely, SRP Steven R. Pannone, P.E. F. ASCE Owner/Civil Engineer 17 September 2024 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP241212, Curtis Townsend, 09/18/24 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP241212, Curtis Townsend, 09/18/24 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP241212, Curtis Townsend, 09/18/24 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP241212, Curtis Townsend, 09/18/24 040.002 Crowther Associates 1632 Bellevue Circle / Anchorage, Alaska 99515 Telephone (907) 349-2198 / E mail: 907crowther@gmail.com Date:September 16, 2024 Client:Pannone Engineering Services, Dan Project:Spruce Terraces, Lot 19 Anchorage, Alaska Particle Size Distribution Table (percent passing subject sieve size) Sample Source Test Pit at 4’Test Pit at 10’ Moisture Content 6.3%6.6% Sieve Size Percent Finer Percent Finer Percent Finer Percent Finer 3 inch 100 100 1-1/2 inch 100 100 ¾ inch 89 92 #4 68 60 #10 52 38 #40 25 13 #100 13 7 #200 10 5 0.02 mm xx xx Classification Gravelly Sand with Silt (SP-SM) Gravelly Sand with Silt (SP-SM) Invoice 193 MUNICIPALITY OF ANCHORAGE Development Services Department Phone: (907)343-7904 On -Site Water & Wastewater Section Fax: (907)343-7997 Certificate of On -Site Systems Approval OSC251302 Parcel ID 020-044-24 Expiration Date: Z. �.d r _ Legal description SPRUCE TERRACES LOT 19 Site address 6937 AVALANCHE CIR. ADU Current property owner(s) MISSION HILLS LLC X The On -site system(s) is/are approved for 5 bedrooms Conditional approval for bedrooms, with the following stipulations: Comments or conditions: M This Certificate of On -Site Systems Approval (COSA) is intended to demonstrate the subject system(s) is/are in substantial compliance with municipal code. The Municipality of Anchorage, Development Service Department (DSD) issues COSAs based upon representations provided by an independent professional engineer. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's submittal. ATTACHMENTS: COSA Checklist X Well Flow Advisory Absorption Field Advisory Nitrate Advisory Tank Age Advisory Arsenic Advisory Other MUNICIPALITY Development Services Department Phone: 907-343-7904 On -Site Water & Wastewater Section t Fax: 907-343-7997 Certificate of On -Site Systems Approval Application 1. GENERAL INFORMATION Parcel I.D. 020-044-24 Complete legal description Spruce Terraces Lot 19 Location (site address) 6935 Avalanche Circle Current property owner(s) Mission Hills, LLC. 2. ON -SITE SYSTEMS SIZED FOR 5 BEDROOMS Day phone 3. TYPE OF WATER SUPPLY: ❑ Private Well serving # dwelling units ❑ Other Non-public well as regulated by MOA ❑ Water Storage 0 Community Well or Public 4. TYPE OF WASTEWATER DISPOSAL: X Private Septic ❑ Private Septic serving 2 dwelling units ❑ Holding Tank ❑ Community Septic or Public Sewer 5. SEPTIC TANK: ❑ Steel X Plastic ❑ Concrete ❑ Fiberglass Age <1 - See advisory if steel or fiberglass older than 20 years 6. ABSORPTION FIELD: ❑ AWWTS ❑ Bed FO-1 Deep Trench ❑ Wide Trench ❑ Seepage Pit Waiver request for: Expedited review requested: ❑ Distance: By applying for this entitlement, this property is subject to inspection by municipal On -site staff to verify the accuracy of the information provided. COSA Fee $ 7 S Waiver Fee $ Date of Payment 7! Z2-14 (/ COSA # )C 2SI L Date of Payment Waiver # COSA Application_Apr2025.doc COSA Checklist_May2025.docx COSA Checklist Legal Description: Parcel ID: If more than 1 well and/or septic system on lot, provide separate checklist. Structure served by this system ____ A. WELL DATA Well log is filed with Onsite (or attached) Date drilled Total depth ft Cased to ft Sanitary seal is functioning correctly Wires are properly protected Casing height (above ground) in. Date of flow test for COSA Static water level at beginning of test ft. Well production at time of test gpm Water storage tank volume gallons Well disinfected for coliform test? Yes No Coliform bacteria is Negative Nitrate mg/L Nitrate less than MRL (ND) Arsenic ug/L Arsenic less than MRL (ND) Collected by Date Comments __________________________________________________________________________________ B. TANK DATA Measured operating fluid level in septic tank Date of pumping Required maintenance completed, if AWWTS Comments: C. LIFT STATION Required maintenance completed Age of lift station years Lift station material Comments: D.DISPOSAL FIELD DATA Which system tested (date installed) ALL standpipes present per record drawing Total measured depth from grade ft (max) Measured depth to pipe invert from grade ft (min) N/A – pressurized field. Per record drawings, field is insulated. Monitor tubes go to bottom of effective. If not, state depth into effective Presoaked required if (Required if house vacant or field not used for more than 30 days prior to date of test) Gallons introduced gallons date Any rejuvenation treatment (past 12 months) If yes, enter date Adequacy test date Results Pass Fluid depth prior to test in Water added gal New fluid depth in Elapsed time min Final fluid depth in Absorption rate gpd FIELD STATUS – POST RECOVERY Effective depth (per record drawings) in Effective depth used in Effective depth remaining in Comments/Deficiencies: E. SEPARATION DISTANCES From Well on Lot to: (Please enter distances if less than required) Septic Tank/Lift Station on Lot > 100’ Yes if No ft Neighboring Tank > 100’ Yes if No ft Disposal Field on Lot > 100’ Yes if No ft Neighboring Disposal Fields > 100’ Yes if No ft Sewer Line/Main > 100’ Yes if No ft Sewer Manhole/Cleanout > 100’ Yes if No ft Sewer Service/Septic Line > 25’ Yes if No ft Holding Tank > 100’ Yes if No ft Animal Containment > 50’ Yes if No ft Manure/Animal Excreta Storage > 100’ Yes if No ft N/A – Served by Community Well (not on lot) or Public Water From Septic/Holding Tank and Disposal Field(s) on Lot to: (Please enter distances if less than required) Tank to Foundation > 10’ Yes if No ft Field to Foundation > 10’ Yes if No ft Tank to Property Line > 5’ Yes if No ft Field to Property Line > 10’ Yes if No ft Water Main/Service Line > 10’ Yes if No ft Surface Water > 100’ Yes if No ft Wells on Adjacent Lots: Wells > 100’ Yes if No ft Community Wells > 200’ Yes if No ft If tank or field is under driveway comment below F.ENGINEER’S COMMENTS G.CERTIFICATION & STATEMENT OF INSPECTION BY ENGINEER Phone Name of Firm Engineer’s Printed Name COSA Checklist_May2025.docx Date As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines, indicates that the on-site water supply and/or wastewater disposal system appears to comply with applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation, unless noted otherwise. In conducting an adequacy test, I attempt to provide a thorough, conscientious engineering analysis of the system in accordance with ADEC & MOA guidelines and regulations. The reported results describe the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soil condition, ground water levels that may fluctuate during the years, and the water usage of the people served by the system. These conditions are outside the control of the evaluator of this system. All systems eventually fail, and satisfactory test results do not guarantee future performance if the system, nor do they guarantee that there are no hidden defects of encroachments. Therefore, we cannot provide any warranty of future performance, nor can we estimate the remaining life of the system. The content of this report is for the sole benefit of the owner listed above.