Loading...
HomeMy WebLinkAboutHULTQUIST HEIGHTS LT 110 ID Hultquist Heights Lot 1 t:,q@vu@ mrAir-Amor.] Municipality of Anchorage On -Site Water and Wastewater Section - (907) 343-7904 Page 1 of 1 ON -SITE WASTEWATER INSPECTION REPORT Permit Number: OSP241300 PID Number: 020-044-03 Dwelling: RN Single Family (SF) EJ with ADU El Duplex (D) El Two Single Family Project: FE New n Upgrade Name Hultquist Homes, Inc. ABSORPTION FIELD W Deep Trench El Wide Trench [] Bed El Mound Site Address 15744 Elizabeth Street El Other Phone of Bedrooms Soil Rating Total depth from original grade 77�� 4 1.2 GPD/SF 10.0 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade 4.0 Ft. Gravel depth beneath pipe 6.0 Ft. Subdivision Block Lot Hultquist Heights 1 Fill added above original grade 0 Ft. Gravel length 42.0 Ft. Township Range Section Gravel width 2.5 Ft. Beds: Number of Lines N/A Distance between lines N/A Ft, SEPARATION DISTANCES To Septic Absorption Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Lift StationTank Line 1504 Ft2 1 N/A Ft. Well 100'+ 100'+ 100'+ NA 25'+ ITANK El Septic Ma S.T.E.P. 0 Holding E] Other IManufacturer Greer Capacity 1500 Gal, Surface Water 100'+ 100'+ 100'+ NA Material Number of compartments Lot Line 5'+ 10'+ 10'+ NA NA HDPE (Deep Burial) 2 Foundation 10'+ *5.5' 10'+ NA LIFT STATIONManufacturer Capacity Remarks * See attached waiver request Orenco 250 Gal. Alarm location House Electrical installed by AKE Electrical Services PIPE MATERIAL House to tank D2661 d Tank to D1785 Installer rainfield Red Dog Masonry, Inc. Drainfield D1785 CO/MT D3034 Inspector PES BENCH MARK (Assumed elevation) 100.0 ft Inspdates:ection vt 07/08/25 nd 07/08/25 Location and description 2 3rd 07/09/25 4 1h 07/14/25 See Site Plan, Top Of Foundation Wall @'BM' ON -SITE WATER AND WASTEWATER SECTION APPROVAL Engineer's Stamp A N l F. AL, Conditional Approval: Date AW . ,ae C-) - 49TH Septic System Approved ...... . ... ........ i>teven R. Pan! gone 1QE 149 3 '4�0 Date J I f Note: this approval does not include well permit requirements. (Kev ubiuu its) 7 EL I Z A B E T H S T R E E T 4 BR SFD 6 7 0 6 6 5 6 6 0 6 5 5 6 5 0 6 4 5 6 7 5 6 8 0 6 8 5 VA C A N T L O T N O DO C U M E N T E D W E L L S OR S E P T I C S 10 ' U t i l E s m t 6 9 0 PAV E D D R I V E ( P ) DE C K TH-3 TH-2 TH-1 101.3 TO WELL 5.5 15.2± WELL (E) WELL (E) INSTALLED DRAIN FIELD (N) 42LF x 2.5'W x 6.0'E.D. x 10.0'T.D. INSTALLED MT AT EACH END USED 1.25''Ø SCH 40 PVC LATERAL W/ 1 8'' HOLES DRILLED 24'' O.C. WELL (E) TH-ANDERSON APPROXIMATE LOCATION PER MOA RECORDS WELL (E) UNNAMED STREAM PER S4 SURVEY 25' STREAM PROTECTION SETBACK RESERVE AREA (NIC) CAT III INSTALLED 1500gal STEP TANK (N) INSTALLED FC BEFORE TANK INSTALLED W/PF2005HH EFFLUENT PUMP WELL (E) 1.25"Ø SCHD 40 PVC FROM LIFT STATION TO DRAIN FIELD MINIMUM 4.0' OF GROUND COVER & 4" OF RIGID INSULATION UNDER DRIVEWAY MH1 MH2 MT2 MT1 A B C DFC BLDG OVERHANGBM 1500 GAL GREER POLY STEP TANK OG/FG: 90.8 FC 86.2 PROFILE SCALE: NTS 1.25"Ø LATERAL W/ 1 8'' HOLES 24'' O.C. DRAIN ROCK 6" ABOVE PIPE INV FILTER FABRIC MT2 6.0' DRAIN ROCK MT1 TEST HOLE PERFORMED: 09/23/2024 DRY: 10/01/2024 95.195.1 GRAVELLY SAND TEST HOLE 3 (OG/FG: 98.6) 82.6 89.1 OG: 99.1 FG (S): 98.1FG (N): 99.0 89.1 MH1 MH2 11 4''Ø SCH 40 PVC DISCHARGE TO DRAIN FIELD 4.0 MIN. PA N N O N E E N G S V C , L L C ( C . I . 1 0 8 8 ) LJ C RE C O R D D R A W I N G HU L T Q U I S T H E I G H T S L 1 HU L T Q U I S T H O M E S SI T E : 1 5 7 4 4 E L I Z A B E T H S T R E E T AN C H O R A G E , A K 11 / 1 7 / 2 0 2 5 02 0 - 0 4 4 - 0 3 OS P 2 4 1 3 0 0 AC P RE V 1 : 1 2 . 0 5 . 2 0 2 5 12 / 0 3 / 2 0 2 5 SI T E P L A N 1" = 6 0 ' 1 O F 2 DESIGN PARAMETERS PRIMARY SEPTIC SYSTEM NO. BEDROOM: 4(600 gpd) TANK SIZE: 1500gal STEP MOA APPROVED SEPTIC TANK PERC RATE: <1.0 MPI SOIL RATING: 1.2 GPD/SF AREA RQD: 500 SF SYS. TYPE: DEEP TRENCH 6.0'ED MIN LENGTH: 42 LF USED: 42LF x 2.5'W x 6.0' E.D., 10.0'T.D. TOTAL AREA: 504 SF RESERVE SEPTIC SYSTEM NO. BEDROOM: 4(600 gpd) TANK SIZE: 1500gal ADVANTEX W/ AX-20 POD PERC RATE: <1.0 MPI SOIL RATING: 6.0 GPD/SF AREA RQD: 100 SF SYS. TYPE: DEEP TRENCH 6.0'E.D. MIN LENGTH: 8.33 LF USE: 10LF x 2.5'W x 6.0' E.D., 10.0'T.D. TOTAL AREA: 120 SF A B FC 9.8 7.9 MH1 62.2 46.2 MH2 66.6 50.7 RECORD DRAWING THIS RECORD DRAWING REPRESENTS THE AS-BUILT CONDITION OF THE PROPERTY IMPROVEMENTS DESCRIBED ABOVE. THE DRAWING AND ANY OTHER SUBSEQUENT ATTACHED OR INCLUDED INFORMATION IS BASED ON PERIODIC VISUAL OBSERVATION BY A REPRESENTATIVE OF PES ALONG WITH NOTES, PHOTOS, AND OTHER INFORMATION PROVIDED BY THE INSTALLER OF THE SYSTEM. THE INFORMATION PROVIDED IN THE RECORD DRAWING APPEARS REASONABLE AND REPRESENTS THAT THE PROJECT WAS DESIGNED AND CONSTRUCTED IN GENERAL CONFORMANCE OF 18 AAC 72, THE ADEC ONSITE WASTEWATER SYSTEM INSTALLATION MANUAL, AND AMC 15.65 WHERE APPLICABLE. PES SHALL NOT BE HELD LIABLE FOR SYSTEM DEFICIENCIES WHICH FALL OUTSIDE THE SCOPE OF THE REQUIRED VISUAL OBSERVATIONS OR SUBSEQUENT OBSERVATIONS IF REQUESTED BY THE INSTALLER. SEPTIC SYSTEM INSTALLERS ARE TRAINED AND APPROVED BY THE MUNICIPALITY OF ANCHORAGE AND OR ADEC AS APPLICABLE. INSTALLERS ARE RESPONSIBLE FOR CONSTRUCTING THE SEPTIC SYSTEM AS DESIGNED AND ENSURING THEIR WORK CONFORMS TO THE CODES AND POLICIES STATED ABOVE. C D MT1 16.3 41.3 MT2 27.8 17.2 ABBREVIATIONS CO CLEAN OUT NO. DCO DOUBLE CLEANOUT DV DIVERTER VALVE (E)EXISTING FC FOUNDATION CLEANOUT FS FLOW SPLITTER MT MONITOR TUBE NO. MH MANHOLE NO. (N)NEW NIC NOT IN CONTRACT (P)PROPOSED TH TEST HOLE TYP TYPICAL NEW SEPTIC WATER LINE / WELL RADIUS ESMT/SETBACK STREAM/DRAINAGE WAY CENTERLINE FLOW PATH Lot 1, Hultquist Heights Land Surveying Land Development Consultants Subdivision Specialists Construction Surveying 124 E 7th Avenue Anchorage, Alaska 99501 (907) 306-8104 mail@S4AK.com AKCAN 173042 Group S4 Asbuilt 0 40' GRAPHIC SCALE 11/5/2025 Certified Drilling Log OWNER OF LAND: Hultquist Homes ADDRESS: 15744 Elizabeth St. Anchorage, AK 99516 LEGAL DESCRIPTION Hultquist Heights LT 1 DATE: 7/8/25 PERMIT NUMBER: OSP241300 DATE OF ISSUE: 10/7/24 TAX IDENTIFICATION NUMBER 02004403000 Is well located at approved permit location: Yes No Method of Drilling: air rotary cable tool Depth of Well: 300’ Casing Type: Steel Wall thickness .250 inches Diameter: 6 inches, depth 68 feet Liner type Static Water Level: 6 feet Recovery Rate 3 gpm gph Method of Testing Air Well Intake Opening Type: open end open hole Screened Start feet Stopped Perforations Start feet Stopped Grout Type: Bentonite Volume: 50 Lbs. Depth: from 2 feet, to 42 feet Well Disinfected Upon Completion: yes no Method of Disinfection: Chlorine 50 PPM Comments: Bore Hole Data Depth From To 0 2 Casing Stickup 2 4 Overburden 4 12 Fill 12 19 Silty sand and gravel 19 29 Silty sand and gravel, water 29 65 Tight silty sand and gravel 65 121 Bedrock gray 121 129 Bedrock gray with quartz 129 251 Bedrock gray 251 284 Bedrock broken 284 300 Bedrock gray Drillers Name: Cole Sullivan ATTENTION: It is the responsibility of the property owner to submit a copy of the well log to the proper authority. Municipality of Anchorage: Department of Health & Human Services and/or Department of Environmental Conservation. MatSu Borough: Department of Environmental Conservation. www.sullivanwaterwells.com Pump Installation Log Well Drilling Permit Number: OSP OSP2413000 Date of Issue 10/7/24 Parcel Identification Number: 02004403000 Legal Description Property Owner Name & Address Hultquist Heights Lot 1 Hultquist Homes 15744 Elizabeth St., Anchorage Pump Installation Date: 7/22/25 Pump Intake Depth Below Top of Well Casing: 292 feet Pump manufacturer’s Name: Grundfos Pump Model: 10SQE10-290 Pump Size: 1 hp Pitless Adapter Burial Depth: 10 feet Pitless Adapter Installer: unk Pitless Manufacturer: Disinfected Upon Completion? yes no Method of Disinfection: Chlorine 50 PPM Comments: Pump Installers Name: Sullivan Water Wells Attention: The pump installer shall provide a pump installation log to the DSD within 30 days of pump installation. Merrill MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Water & Wastewater System Permit Permit Number: OSP241300 Work Type: WellSeptic Initial Tax Code Number: 02004403000 Site Legal Address: HULTQUIST HEIGHTS LT 1 G:3238 Site Mailing Address: 15744 ELIZABETH ST, Anchorage Owner: HULTQUIST HOMES INC Design Engineer: PANNONE ENGINEERING SERVICES This permit is for the construction of: Effective Date Expiration Date: Lot Size in Sq Ft: Total Bedrooms: r I)epartill ent 10/7/2024 10/7/2025 63465 Q Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy Q Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing -Reeeived-By: r 15,5v��a� Issued By: (�l/ Date: Date: 4 MUNICIPALITY OF ANCHORAGE Y� Community Development Department Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On -Site Water e Wastewater Program ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 020-044-03 Property owner(s) Hultquist Homes Day phone Mailing address 12570 Old Seward Hwy Site address NHN Elizabeth Street Legal description (Sub'd., Block & Lot) Hultquist Heights L1 Legal description (Township, Range & Section) Lot Size 63,465 Sq. Ft. Number of Bedrooms APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (® all that apply) Absorption Field x❑ Initial R Single Family (SF) x❑ (w/wo ADU) Septic Tank RX Upgrade ❑ Duplex (D) ❑ Holding Tank ❑ Renewal ❑ Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑x Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: 12 Date of Payment: y Receipt Number: 12-K06 Permit No. a.,e 2 q ( - 00 Permit App_'-'- : • :'-.,'c Waiver Fees: Date of Payment: Receipt Number: Waiver No. Pannone Engineering Services LLC Steven R. Pannone, Principal Registered Professional Engineer E-mail: steve@panengak.com Mailing: P.O.Box 1807, Palmer, AK 99645 Telephone: (907) 745-8200 FAX: (907) 745-8201 Municipality of Anchorage Development Services Department On-Site Water & Wastewater Program 4700 Elmore Road Anchorage, Alaska Subject: Hultquist Heights L1 Well and Septic System Permit Request This is a design narrative for a permit to install an initial well and septic system on the subject property. The proposed installation will serve a proposed four (4) bedroom house. This lot and surrounding lots are served by private wells. Currently there are no wells within 100 feet of the proposed wastewater treatment system. 1. Soils: A test hole was performed on this lot by Pannone Engineering Services on 09/23/2024. Groundwater was not observed during the excavation of the test hole to a depth of 16 feet, and bedrock was not encountered. Groundwater was not observed in the test hole monitor tube after 7-day. Based on the results of the percolation test and attached sieve analysis an application rate of 1.2 gpd/SF was used for the design of a conventional wastewater treatment system in the area of the test hole. 2. Soil Absorption System Design: See Sheet 1 of the design package. 3. Surface Water: There are unnamed streams on this property as mapped MOA ARC GIS. The proposed location for the drain field and septic tank creates at least 100 feet of overland flow between the wastewater treatment system and the stream. 4. Topography: See attached site plan for area topography. 5. Drawing Markings: The Drawings are marked “For MOA Review Only”. When written notification that the review is complete and no further comments are received from MoA On-Site Department, the note will be removed and “For Construction” drawings will be issued. The proposed installation will not affect the future development of this or the surrounding lots. If you have any questions or concerns, please contact me at (907) 745-8200. Sincerely, SRP Steven R. Pannone, P.E. F. ASCE Owner/Civil Engineer 4 October 2024 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP241300, Deb Wockenfuss, 10/07/24 t (ZDtoco Q7 I I �rram' cC) n1acnC-0)]:�i co n'O Orpp�Z�Oz��� ���O� n 'S nh�0zZ2�'�-�CC��(ZpOryZ � I I ( �N rc'nt ]a cn m• . ��z ��I�n�" p�O�y(rq������O�y��nlOpt� �Z T G7' rr CZE t p Q oow�mz�'z (/) I I I Orn Qn Q.-Tj Q) OC)-N oO� �(nn'�LoQ)-Arty ��Aozo r' 0 In v' o ,� �1 C) ° o cn o '+ "1 c) � o o - 1� TIZ p� h0Ql Z \�� O - � rn M Or- D-u -u vfD7^ N-1W-1 xrnrN n0,*WJMDm - \ ry ? C N N=.mD mmo rno I \ /^645 to p22ZAA2~' 2 Z Om C O�Zr;Un :V �7 n lm p Cnr ��UiD=y A SM �Ln Fj �r 02OOr ti mnn� 'p�mr"0rmmLn-� \ / \ \ b0-1oxa y --Zi-ZI�U)�1 -0 ZmDD ` �/ - -650\ t�0 �' I (. rtT�1nOZAox -oR�'*1 m 2 O z \ .� zmmm �'rn OCZ o \ / q \�n� _ 4 �� c2'i0Aan2�r m==� O rin 00-�- - \ Y� A- L, 1 22 Twv m -D1m�D� D�zm�= \\ 1'� -'- -_ I Ob 2C1'1 2 U�j�mD OCOAOom r, -'� A 1� \ �Snvmi yOVzi -1zo '''1� \ �� \ \ I 2U) to aAy zr�0o OOmr�*1Np \ ll�\vl�nA b~� mD�� v z�ou .m \ \ _ \ \ ( m� im ozo �m a oomcznn O�r7l Ln 0 \ \ \ \ / \ "n cn ONmm� r SOD --ISO \ \ \ `�m2iN M,i mm �m6mm O / D ZmIZn UI SooZ�� \ r r \ bAAO �XO O r N 77 J 2 m o c00 m50-1<m \ o Zzzo�) ozz9zw -p o m cnn%ll�D 0 Z � n2 �/ yy ~2AC r-(,� zw-iimm zzc�o¢ \ ram — oi'l --660_ / brl _Aoa rn•1Dm-t'*1 t'aaNmmom \ \ �mn� > �aaV) U) GZ') ,-LOj n Z D m \ Y tb n retry n1 _ ••� A •t �nz Kozo-� I--occox o�ooN Z / / �i�� oiA D-02 �N�= o �; A'�p m�b2s AAY� 6o0'i mZ;,- �O= ir, ._.- _ >� .anfi0tn �p2 i 665 moms -oxo m,mmmm ''� o� Cm Oo n a-�1 / btn20 Ob Nt11 m- �C>- I Z$2o AavAi / �67 -0OZ '0• o ♦ to tnO mMO �OC.9 M 0=� 1 N C 2a�0 2 rr--Immn K z�� \ \ `u om • m�o 00 675� O,O,,yA� Fyo 'm2AQ F; �>� \ \ ,n°, �A mizao� tn� C ( O'220 D0oNz-CO \ \ / o * 680-�\ 2c2 �Oo Uzi Z �OmZ :' \ o m-u -I m m '�='aonotyy>0 OnCzZ C A >08, c \ph O� my w fi/ Esmf m oO t1 A to � n S r yo�om v 0> / �y 7�x r m� �n2- ELIZA8 HST EET 2 m ,'tmj�D 3 �On Zr~i �i� Otn_ nD �ON� 2a�2 _roc A C--Hv) nOb L/ C z 2 O - C- ZOm- C,~r7 - _ - - - _ - - - - _ - - _ _. n*;o Z 0;o _I �F AA � z n \ ~ x O `� C CLn D m Z Z -, o 2 0 a H Z „b) ti A VA o 9T NO DOCUMENTED W£LLS\, OR S£PTICS ,.,1 X" O 0M 9i0 C a r , mmm, D Ztmllm mZ U) XMF�n:E In ZN 2 O OONrr �� \\V ' m \ V I NOTES: PANNONE ENG SVC LLC (C.1. 1088) P.O. BOX 1807 PALMER, AK 9645 PHONE 907 745-8200 FAX 907 745-8201 ..�������t„ �''(E OF A�q)''h, _ �P '" S� 4, 9'�, �.....4. '. Ic. St... R8t4 -- ; CE-SITE: 4, 05/19/2025_ a�a;��,.. 'tti,........�� REVISIONS UAIL 9/3/2024 FOR CONSTRUCTION REV 1: 2024.t0.02 CHANGE ORDER HULTQUIST HEIGHTS L1 HULTQUIST HOMES NHN ELIZABETH STREET ANCHORAGE, AK REV 2: 2025.05.19 SCALE 1" = 60' DRAWN acP P.I.D. NO 020-044-03 CHECKED sRP SITE PLAN PERMIT NO. OSP241300 SHEET 1 OF 3 PA N N O N E E N G S V C , L L C ( C . I . 1 0 8 8 ) A SCALE: 1"=5' DRAIN FIELD SECTION Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP241300, Deb Wockenfuss, 10/07/24 PA N N O N E E N G S V C , L L C ( C . I . 1 0 8 8 ) 2.2. SCOPE OF WORK: INSTALL SYSTEM IN ACCORDANCE WITH THE ATTACHED DESIGN AND SPECIFICATIONS. 16 FEET 16 FEET Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP241300, Deb Wockenfuss, 10/07/24 PA N N O N E E N G S V C , L L C ( C . I . 1 0 8 8 ) COMMENTS: Test hole excavated by HULTQUIST HOMES. PERFORMED BY: PANNONE ENGINEERING SERVICES, LLC. I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDLINES IN EFFECT ON THE DATE OF THIS TEST. ·<1.0 (min/inch) ·6" ·4 FT AND 5 FT SOILS LOG & PERCOLATION TEST Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP241300, Deb Wockenfuss, 10/07/24 040.002 Crowther Associates 1632 Bellevue Circle / Anchorage, Alaska 99515 Telephone (907) 349-2198 / E mail: 907crowther@gmail.com Date:September 27, 2024 Client:Pannone Engineering Services, Dan Project:Hultquist Heights Lot 1 Anchorage, Alaska Particle Size Distribution Table (percent passing subject sieve size) Sample Source Lot 1 Moisture Content 4.8% Sieve Size Percent Finer Percent Finer Percent Finer Percent Finer 3 inch 100 1-1/2 inch 100 ¾ inch 82 #4 56 #10 41 #40 13 #100 6 #200 5 0.02 mm xx Classification Gravelly Sand (SP) Invoice 226 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP241300, Deb Wockenfuss, 10/07/24 .Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 Elmore Road P.O. Box 196650 Anchorage, AK 99507 www.ci.anchorage.ak.us (907)343-7904 1 LR'S:3FLp a 41.° Y' o 497H f°•• °o rg} e 0 o b s o s o b O o 0 o b b o e oJ 777rrr"' , MICHAEL N, ANDERSON ; FS e �..i, CE -9469 •,Ci~ �' �� Soils Log - Percolation Test t ° ° ° • ° ° • °,,�� Performed For: C06 �j 1 k a u is -j- Date Performed: Legal Description: _ 0pg4cjz_ hi u� �� ���(�-��_ Township, Range, Section: G U Slope COMMENTS WAS GROUND WATER ENCOUNTERED? 1� 7 Depth s L O Depth to Water After / P Monitoring? E (Feet) Date: �a z Z r 3 (4f11 m��jG1ttG �j 1- 2- 3- 4- 5- 6- rr a >1`d.,,e l 7- -8-9-10- 8- 9- 10- '�C. Gna 11- 12- 13- 14- 15 0 Wern 16- 17- 18- 19 - COMMENTS WAS GROUND WATER ENCOUNTERED? 1� 7 IF YES, AT WHAT DEPTH? s L O Depth to Water After / P Monitoring? E W tt�f r ® Date: �a z Z r 3 (4f11 Site Plan r,o .— n ( f - I PERCOLATION RATE?(minutesfinch) PERC HOLE DIAMETER 6_ TEST RUN BETWEEN FT AND FT PERFORMED BY: (\11A( . 1 CERTIFY THAT THIS TEST WA PERFORMED IN ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: A51 zz MUNICIPALITY OF ANCHORAGE Development Services Department Phone: (907)343-7904 On -Site Water & Wastewater Section Fax: (907)343-7997 Certificate of On -Site Systems Approval OSC251540 Parcel ID 020-044-03 Expiration Date: z Legal description HULTQUIST HEIGHTS LT 1 Site address 15744 ELIZABETH ST Current property owner(s) HULTQUIST HOMES, INC. X The On -site system(s) is/are approved for 4 bedrooms Conditional approval for bedrooms, with the following stipulations: Comments or conditions: By: Curtis Townsend Original Certificate Date: 12/9/2025 This Certificate of On -Site Systems Approval (COSA) is intended to demonstrate the subject system(s) is/are in substantial compliance with municipal code. The Municipality of Anchorage, Development Service Department (DSD) issues COSAs based upon representations provided by an independent professional engineer. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's submittal. ATTACHMENTS: COSA Checklist X Well Flow Advisory Absorption Field Advisory Nitrate Advisory Tank Age Advisory Arsenic Advisory Other MUNICIPALITY Development Services Department Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Certificate of On -Site Systems Approval Application 1. GENERAL INFORMATION Parcel I.D. 020-044-03 Complete legal description Hultquist Heights Lot 1 Location (site address) 15744 Elizabeth Street Current property ownerHultuist Homes, Inc, s) � Day phone 2. ON -SITE SYSTEMS SIZED FOR 4 BEDROOMS 3. TYPE OF WATER SUPPLY: R Private Well serving # 1 dwelling units ❑ Other Non-public well as regulated by MOA ❑ Water Storage ❑ Community Well or Public 4. TYPE OF WASTEWATER DISPOSAL: R Private Septic ❑ Private Septic serving 2 dwelling units Holding Tank ❑ Community Septic or Public Sewer 5. SEPTIC TANK: ❑ Steel ❑ Plastic ❑ Concrete ❑ Fiberglass Age C 1 - See advisory if steel or fiberglass older than 20 years 6. ABSORPTION FIELD: ❑ AWWTS ❑ Bed ❑ Deep Trench ❑ Wide Trench ❑ Seepage Pit Waiver request for: Field to Foundation Distance: 5•5' Expedited review requested: ❑ By applying for this entitlement, this property is subject to inspection by municipal On -site staff to verify the accuracy of the information provided. COSA Fee $ 7 5 Waiver Fee $ Date of Payment IIIX124 Date of Payment ' COSA # C 5� S�iU Waiver # Ofy2u55 COSA Application Apr2025,doc COSA Checklist Legal Description: Hultquist Heights Lot 1 Parcel ID: 020-044-03 If more than 1 well and/or septic system on lot, provide separate checklist. Structure served by this system 1 A. WELL DATA 0 Well log is filed with Onsite (or attached) Date drilled 07/08/2021 Total depth 300 ft Cased to 68 ft rN-1 Sanitary seal is functioning correctly A Wires are properly protected Casing height (above ground) 24 in. Date of flow test for COSA 07/08/2025 Static water level at beginning of test 6.0 ft. Comments B. TANK DATA Measured operating fluid level in septic tank New Date of pumping N/A ❑ Required maintenance completed, if AWWTS Comments: New System D. DISPOSAL FIELD DATA Which system tested (date installed) 07/08/2025 0 ALL standpipes present per record drawing Total measured depth from grade 9.0 ft (max) Measured depth to pipe invert from grade ft (min) M N/A — pressurized field. ❑ Per record drawings, field is insulated. Q Monitor tubes go to bottom of effective. If not, state depth into effective ❑ Presoaked required if (Required if house vacant or field not used for more than 30 days prior to date of test) Gallons introduced gallons date Any rejuvenation treatment (past 12 months) no If yes, enter date Comments/Deficiencies: COSA Checklist_May2025.docx Well production at time of test 3.0 gpm Water storage tank volume none gallons Well disinfected for coliform test? n Yes ❑ No no Coliform bacteria is Negative Nitrate mg/L n Nitrate less than MRL (ND) Arsenic ug/L X Arsenic less than MRL (ND) Collected by Sullivan Water Wells Date 07/22/2025 C. LIFT STATION ❑ Required maintenance completed Age of lift station <1 years Lift station material HDPE Comments:. New System Adequacy test date New System Results Q Pass Fluid depth prior to test in Water added gal New fluid depth in Elapsed time min Final fluid depth in Absorption rate 600 gpd FIELD STATUS — POST RECOVERY Effective depth (per record drawings) 72 in Effective depth used 0 in Effective depth remaining 72 in E. SEPARATION DISTANCES From Well on Lot to: (Please enter distances if less than required) Septic Tank/Lift Station on Lot > 100' Z Yes if No ft Neighboring Tank > 100' M Yes if No ft Disposal Field on Lot > 100' Q Yes if No ft Neighboring Disposal Fields > 100' Yes if No ft Sewer Line/Main > 100' [71 Yes if No ft Sewer Manhole/Cleanout > 100' (Z✓ Yes if No ft Sewer Service/Septic Line > 25'M Yes if No ft Holding Tank > 100' Q✓ Yes if No ft Animal Containment > 50' Ql Yes if No ft Manure/Animal Excreta Storage > 100' QYes if No ❑ N/A — Served by Community Well (not on lot) or Public Water From Septic/Holding Tank and Disposal Field(s) on Lot to: (Please enter distances if less than required) Tank to Foundation > 10' F.71 Yes if No ft Surface Water > 100' Q Yes if No Field to Foundation > 10' ❑ Yes if No *5.5 ft Wells on Adjacent Lots: Tank to Property Line > 5' ❑✓ Yes if No ft Wells > 100' Yes if No Field to Property Line > 10' Yes if No ft Community Wells > 200' [?]Yes if No Water Main/Service Line > 10' Yes if No ft If tank or field is under driveway comment below F. ENGINEER'S COMMENTS *See attached waiver request. G. CERTIFICATION & STATEMENT OF INSPECTION BY ENGINEER ft ft ft ft As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines, indicates that the on -site water supply and/or wastewater disposal system appears to comply with applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation, unless noted otherwise. In conducting an adequacy test, I attempt to provide a thorough, conscientious � engineering analysis of the system in accordance with ADEC & MOA guidelines and OF q 0 lll regulations. The reported results describe the performance of the system under the �C,'t C �S, conditions encountered at the time of the test, and separation distances measured to Gj _ •:9 readily identifiable features. The operational life of all wells and septic systems depend W 49 TH on the local soil condition, ground water levels that may fluctuate during the years, and the water usage of the people served by the system. These conditions are outside the ® - � • • . • • • . Steven F annone a control of the evaluator of this system. All systems eventually fail, and satisfactory test CE 8149 `>® results do not guarantee future performance if the system, nor do they guarantee that there are no hidden defects of encroachments. Therefore, we cannot provide anyvp�G warranty of future performance, nor can we estimate the remaining life of the system. The content of this report is for the sole benefit of the owner listed above. Name of Firm Pannone Engineering Services, LLC. Engineer's Printed Name Steven R. Pannone Phone (907)745-8200 Date 12/03/2025 COSA Checklist_May2025.docx Pannone Engineering Services LLC Steven R. Pannone, Principal Registered Professional Engineer E-mail: steve@panengak.com Mailing: P.O. Box 1807, Palmer, AK 99645 Telephone: (907) 745-8200 FAX: (907) 745-8201 Municipality of Anchorage Development Services Department On-Site Water & Wastewater Program 4700 Elmore Road Anchorage, AK Subject: Hultquist Heights Lot 1 Drain Field to Foundation Waiver Request Ladies and Gentlemen: We hereby request a separation distance waiver from the newly installed drain field to the existing foundation on the subject property to a distance of five-point-five (5.5) feet. A deep trench absorption field was installed on the subject property during the construction of the dwelling located on this lot. Due to space limitations between the proposed dwelling and the eastern utility easement, the subject drain field was installed at a lesser distance than the prescriptive ten (10) foot separation to maintain clearance from the existing utility easement and retain required setbacks. The native receiving soil at the trench location consists predominantly of poorly graded sands (SP), with rapid infiltration characteristics verified by sieve analysis and percolation testing (<1.0 min/in.). Based on an estimated worst-case infiltration condition (46% infiltration from the drain field lateral), the vertical zone of influence from the drain field i s projected to extend approximately just above the existing foundation foot ing. The dwelling is constructed on a CMU stem wall and concrete footing. This foundation was waterproofed in accordance with standard constructi on practices. Effluent bio-mat build-up is generally confined to within a limited distance from any drain field boundary . In an area with confirmed well-draining soils; the anticipated soil infiltration of effluent is likely to occur at a steeper angle exhibiting more of a vertical than horizontal infiltration gradient. The placement of the drain field is not likely to have any adverse impacts on the native soils in which are supporting the foundation. In accordance with the Alaska Department of Environmental Conservation (ADEC) regulations for On -site Wastewater Treatment Systems (18 AAC 72 & most recent On-Site Wastewater Installation Manual) the horizontal separation from foundation to absorption field of ten (10) feet –is not listed as a requirement but only as recommendation. Given these conditions, we believe the installed separation provides adequate protection of the structure. Granting this waiver is not likely to affect the health and safety of this lot or the surrounding lots now or in the future. Furthermore, granting this waiver will not hinder the future development of this or surrounding lots. If you have any questions, please contact me at (907)-745-8200. Sincerely, Steven R. Pannone, P.E., F. ASCE Owner/Civil Engineer 3 December, 2025 Municipality ®i ?, I rportmont ! P.O. Box 196650 0 4700 Elmore Road Anchorage, Alaska 99519-6650 0 (907) 343-7904 0 Fax (907) 343-7997 http://www.muni.org/Onsite Development Services Division On -Site Water and Wastewater Program * * * * VARIANCE/WAIVER REVIEW * * * * Waiver#: OSV251540 COSA#:OSC251055 Permit#: P I D#: 020-044-03 Legal Description: HULTQUIST HEIGHTS LT 1 Engineer: Pannone Engineering Services Your request for a waiver of the required 10 feet horizontal separation from the disposal field to the foundation has been approved. The approved separation distance is 5.5 feet. This waiver approval applies to the existing disposal field only. Any future upgrade to the on - site wastewater disposal system will require all separation distances be met or another approval from this department. Waiver is Granted: X Waiver is not Granted: j )�:: G Date: 2 Approved by: / Name of a fewer **** VARIAN G EMAIVE R REVIEW ****