HomeMy WebLinkAboutPIONEER ESTATES BLK 2 LT 7PIONEER ESTATES
Lot 7
57-091 - 15
MUNICIPALITY OF ANCHORAGE
On -Site Water & Wastewater Program
PO Box 196650 4700 Elmore Road
Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997
hftp://www.muni.org/onsite
On -Site Water & Wastewater System Permit
Permit Number: OSP241321
Work Type: WellSeptic Initial
Tax Code Number: 05709115000
Site Legal Address: PIONEER ESTATES BLK 2 LT 7 G:1412
Site Mailing Address: 38281 RAYMOND AVE, Chugiak
Owner: MARBLE SCOTT & DIANE
Design Engineer: PANNONE ENGINEERING SERVICES
This permit is for the construction of:
Effective Date:
Expiration Date
Lot Size in Sq Ft:
Total Bedrooms:
10/22/2024
10/22/2025
103200
✓❑ Disposal Field 0 Septic Tank ❑ Holding Tank ❑ Privy Q Private Well ❑ Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
Received By:
Issued By:
Date:
Date: 2,
/ 2-o
3
On -Site Water & Wastewater Program
ON -SITE SEWER/WELL PERMIT APPLICATION
Parcel I.D. 057-091-15
Property owner(s) Scott & Diane Marble Day phone
Mailinq address
Site address 38281 Raymond Avenue
Legal description (Sub'd., Block & Lot) Pioneer Estates Block 2 Lot 7
Legal description (Township, Range & Section)
Lot Size -103,200 _Sq. Ft. Number of Bedrooms 3
APPLICATION IS FOR:
APPLICATION IS AN:
TYPE OF DWELLING:
(N all that apply)
Absorption Field
RX
Initial FRI
Single Family (SF) nX
(w/wo AD U)
Septic Tank
Upgrade
Duplex (D) ❑
Holding Tank
❑
Renewal ❑Multiple
Dwellings ❑
Privy
❑
(SF and/or D)
Private Well
nX
Water Storage
n
THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit/Rush Fees: Z-,-D
Date of Payment: Ll
Receipt Number:
Permit No.
Waiver Fees:
Date of Payment:
Receipt Number:
Waiver No.
Permit App_'-'-:.
Pannone Engineering Services LLC
Steven R. Pannone, Principal
Registered Professional Engineer
E-mail: steve@panengak.com
Mailing: P.O.Box 1807, Palmer, AK 99645
Telephone: (907) 745-8200 FAX: (907) 745-8201
Municipality of Anchorage
Development Services Department
On-Site Water & Wastewater Program
4700 Elmore Road
Anchorage, Alaska
Subject: Pioneer Estates Block 2 Lot 7
Septic System Initial Permit Request
This is a design narrative for a permit to install an initial well and septic system on the subject property. The
proposed installation will serve a proposed three-bedroom (3) house. This lot and surrounding lots are served by
private wells. Currently, there are no wells within 100 feet of the proposed installation.
1. Soils: A test hole was performed on this lot by Pannone Engineering Services, LLC on 08/26/2024. Groundwater
was not observed during the excavation of the test hole and bedrock was not encountered. Groundwater was
not observed in the test hole monitor tube after 7-days to a depth of 15.0 feet below grade. Based on the results
of the percolation test and overall soils appearance an application rate of 1.2 gpd/SF was used for the design of
a conventional wastewater treatment system in the area of the test hole.
2. Soil Absorption System Design: See Sheet 1 of the design package.
3. Surface Water: There is no surface water within 100 feet of the proposed septic tank and drain field.
4. Topography: See attached site plan for area topography.
5. Drawing Markings: The Drawings are marked “For MOA Review Only”. When written notification that the
review is complete and no further comments are received from MoA On-Site Department, the note will be removed
and “For Construction” drawings will be issued.
The proposed installation will not affect the future development of this or the surrounding lots.
If you have any questions or concerns, please contact me at (907) 745-8200.
Sincerely,
SRP
Steven R. Pannone, P.E. F. ASCE
Owner/Civil Engineer
23 September 2024
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP241321, Curtis Townsend, 10/22/24
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP241321, Curtis Townsend, 10/22/24
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP241321, Curtis Townsend, 10/22/24
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP241321, Curtis Townsend, 10/22/24
040.002 Crowther Associates
1632 Bellevue Circle / Anchorage, Alaska 99515
Telephone (907) 349-2198 / E mail: 907crowther@gmail.com
Date:September 16, 2024
Client:Pannone Engineering Services, Logan
Project:38281 Raymond Avenue
Chugach, Alaska
Particle Size Distribution Table
(percent passing subject sieve size)
Sample Source --
Moisture
Content
3.8%
Sieve Size Percent Finer Percent Finer Percent Finer Percent Finer
3 inch 100
1-1/2 inch 100
¾ inch 87
#4 62
#10 44
#40 15
#100 7
#200 7
0.02 mm xx
Classification Gravelly
Sand with Silt
(SP-SM)
Invoice 224