HomeMy WebLinkAboutOVERLOOK ESTATES #3 LT 20OVERLOOK ESTATES
067- 231 - 33
MUNICIPALITY OF ANCHORAGE
On -Site Water & Wastewater Program
PO Box 196650 4700 Elmore Road
Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997
http://www.muni.org/onsite
On -Site Water & Wastewater System Permit
Permit Number: OSP241394
Work Type: WellSeptic Initial
Tax Code Number: 06723133000
Site Legal Address: OVERLOOK ESTATES #3 LT 20 G:
Site Mailing Address: 27425 WILDE CIR, Eagle River
Owner: HAND RICHARD & PEGGY
Design Engineer: FORGE ENGINEERING
This permit is for the construction of:
Q Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy
Effective Date:
Expiration Date:
Lot Size in Sq Ft:
Total Bedrooms:
t)cpartanr.nt
12/6/2024
12/6/2025
54720
Z Private Well ❑ Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
Special Provisions:
7 day groundwater monitoring is required. Construction may proceed at your own risk before the 7 day water
monitoring is complete. Please submit stamped and signed results with the As -built Inspection Report. If the
results require a design change, construction of the system will stop pending On -Site review and approval.
4
Received By: i � � �`�� � � Date: 2-1
Issued By: Date:' y
MUNICIPALITY OF
Development Services Department
On -Site Water & Wastewater Section
Parcel I.D. 067-231-33
ANCHORAGE
ON -SITE SEPTIC/WELL PERMIT APPLICATION
Property owner(s) Richard & Peggy Hand Day phone
Mailing address 18306 Gavin Cir, Eagle River, AK, 99577
Site address27425 Wilde Cir, Eagle River, AK, 99577
Legal description Overlook Estates #3, Lot 20
Number of Bedrooms 4
Engineering Firm Forge Engineering
Building Permit Number R24-3126 Not Applicable F-1
APPLICATION IS FOR: APPLICATION IS AN:
(Z all that apply)
Absorption Field
M Initial M
Septic Tank
Upgrade EJ
Holding Tank
❑ Renewal ❑
Privy
❑
Well
THIS APPLICATION INCLUDES A WAIVER REQUEST FOR:
Permit/Rush Fees: %Waiver Fees:
Date of Payment: 2 t 5- ?0 Date of Payment:
Permit No. D S P'L V /_3 9 ' Waiver No.
Phone- 907-343-7904
Distance:
December 4, 2024
MOA Development Services, On-Site Water & Wastewater Program
4700 Elmore Rd
Anchorage, AK 99507
Subject: Overlook Estates #3, Lot 20 – 27425 Wilde Circle
Septic system design
Dear On-Site Services Engineer:
The owner of the above lot intends to build a new 4-bedroom home on the property, so we are
submitting this permit application for the construction of a new well and septic system. The
attached site plan identifies the location of the home as well as the proposed well, septic location
and alternate site. No conflicts exist between this proposed system and any other well or septic
system, whether on this lot or adjacent lots.
The ground surface on the lot slopes toward the south moderately from the back of the lot at about
a 10-15% slope. There are no slopes greater than 25% within 50 feet downslope of either the
primary or alternate site. Contours are shown on the site plan showing the grade and direction of
flow. Stormwater drainage will not impact this septic system. The new trench will be constructed
parallel to the slope as much as possible.
The trenches will be located uphill from the house, but the contractor is confident that he can install
them deeper to avoid putting in a lift station. We have specified on the septic section that the
maximum depth is 12’ to ensure separation to impermeables.
Wells on this and adjacent lots are shown. The new system will be a minimum of 100’ from all
wells and surface water, and more than 5’ away from the septic tank. The alternate site is located
more than 6’ away. Please refer to the attached test hole logs, plan and profile pages for the septic
design. If this design is followed, there will be no adverse impacts to adjacent properties.
Sincerely,
Benjamin Schiller, PE
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP241394, Curtis Townsend, 12/06/24
Benjamin Schiller
CE 12592REGISTEREDPROFESSION A L E N GINEER
1"=50'
CO - CLEANOUT
2CO - DOUBLE CLEANOUT
FCO - FOUNDATION CLEANOUT
FS - FLOW SPLITTER VALVE
MH - MANHOLE
MT - MONITORING TUBE
SV - SEPTIC VENT
TH - TEST HOLE
LEGEND
OVERLOOK ESTATES #3, LOT 20
FEET
0 50 100
SEPTIC PLAN
12/4/24
4-BDRM HOME
15'
TE
G
E
A
S
E
M
E
N
T
W
I
L
D
E
CI
R
C
L
E
EA
G
L
E
R
I
V
E
R
R
O
A
D
380
380
370
370
390
390
400
400
ALTERNATE SITE
PROPOSED WELL w/ 100' RADIUS
(2) 60' LONG x 5' WIDE, 6" EFFECTIVE
DEPTH ABSORPTION TRENCHES
1250-GAL
SEPTIC TANK
2CO
SV
MH
FCO
CO
CO
CO
FS CO
MT
MT
MT
MT
410
>5'
TH#1
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP241394, Curtis Townsend, 12/06/24
OVERLOOK ESTATES #3, LOT 20
TYPICAL TRENCH SECTION
(NO SCALE)
NOTES:
1. GRADE AREA OVER TRENCH TO DRAIN AWAY
2. PROVIDE 3' OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2'
WITH 2" OF INSULATION
3. CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER
THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY
Benjamin Schiller
CE 12592REGISTEREDPROFESSION A L E N GINEER
4" PERFORATED PVC (HOLES DOWN)
DRAINFIELD ROCK
6"
6'
6"
DESIGN FACTORS:SYSTEM REQUIREMENTS:
600 GPD PEAK FLOW
PERK RATE: <1 MIN/IN
APPLICATION RATE: 1 GPD/SF
5' WIDE TRENCH SYSTEM
1250-GAL SEPTIC TANK
BOTTOM OF TRENCH: 7' BELOW GRADE (MAXIMUM OF 12')
FLOW LINE ELEVATION: 6' 6" BELOW GRADE
600 GPD / 1 GPD/SF / 5' WIDE * 1.00 RED FACTOR [0.5' DEEP] = 120 LF TRENCH REQUIRED
(120 LF SPECIFIED)
GEOTEXTILE FABRIC
6"
12/4/24
PROVIDE ADDITIONAL FILL TO
ACCOUNT FOR SETTLEMENT
5'
2'
MOA APPROVED SAND
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP241394, Curtis Townsend, 12/06/24
LEGAL DESCRIPTION:
PERFORMED FOR:
DATE: PARCEL ID#:
SOILS LOG AND PERCOLATION TEST
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
DEPTH
(feet)
TEST HOLE 1
DATE READING START TIME NET TIME
(minutes)
DEPTH to
WATER NET DROP
PERCOLATION RATE: (MIN/INCH)
(inches)(inches)
DATE OF MONITORING
WAS WATER ENCOUNTERED?
DEPTH TO WATER AFTER MONITORING
IF YES @ WHAT DEPTH?
0.08
12/3 1
2
3
4
5
6GP (SILTY SANDY GRAVEL)
Professional Engineers Stamp:
NO
OVERLOOK ESTATES #3, LOT 20
12/3/2024 067-231-33
KOUROSH PARTOW
3:25 1 0
16
1' OB
0:18
Benjamin Schiller
CE 12592REGISTEREDPROFESSION A L E N GINEER
PERC TEST LOCATION
TECHNICIAN: J.OPHEIM
7 0
16
-
-
-
COMMENTS:
SITE PLAN
6 0
16
USCS SOIL CLASSIFICATION WAS VISUALLY DETERMINED
12/4/24
3:26 1 0
160:24 7 0
16 6 0
16
3:27 1 0
160:26 7 0
16 6 0
16
3:27 1 0
160:28 7 0
16 6 0
16
3:28 1 0
160:29 7 0
16 6 0
16
3:29 1 0
160:30 7 0
16 6 0
16
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP241394, Curtis Townsend, 12/06/24