HomeMy WebLinkAboutOVERLOOK ESTATES #3 LT 20OVERLOOK ESTATES 067- 231 - 33 MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 hftp://www.muni.org/onsite On -Site Water & Wastewater System Permit Permit Number: OSP241394 Work Type: WellSeptic Initial Tax Code Number: 06723133000 Site Legal Address: OVERLOOK ESTATES #3 LT 20 G: Site Mailing Address: 27425 WILDE CIR, Eagle River Owner: HAND RICHARD & PEGGY Design Engineer: FORGE ENGINEERING This permit is for the construction of: Effective Date Expiration Date: Lot Size in Sq Ft: Total Bedrooms: 12/6/2024 12/6/2025 54720 Q Disposal Field Z Septic Tank ❑ Holding Tank ❑ Privy Q Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Special Provisions: 7 day groundwater monitoring is required. Construction may proceed at your own risk before the 7 day water monitoring is complete. Please submit stamped and signed results with the As -built Inspection Report. If the results require a design change, construction of the system will stop pending On -Site review and approval. rd CO It _ 14-\.�5 >r � c_p c '� r �j) �� t �a M fF✓aAl % 41 E -c- T1 _ 5 r ("! (� V1 /'tom (,i.iv%�i.V'.� '%�./2-- C`,�✓/J / Received By: �' %t�'� Date: Issued By: Date: Z 2,z' Z MUNICIPALITY OF Development Services Department On -Site Water & Wastewater Section Parcel I.D. 067-231-33 ANCHORAGE ON -SITE SEPTIC/WELL PERMIT APPLICATION Property owner(s) Richard & Peggy Hand Day phone Mailing address 18306 Gavin Cir, Eagle River, AK, 99577 Site address27425 Wilde Cir, Eagle River, AK, 99577 Legal description Overlook Estates #3, Lot 20 Number of Bedrooms 4 Engineering Firm Forge Engineering Building Permit Number R24-3126 Not Applicable F-1 APPLICATION IS FOR: APPLICATION IS AN: (Z all that apply) Absorption Field M Initial M Septic Tank Upgrade EJ Holding Tank ❑ Renewal ❑ Privy ❑ Well THIS APPLICATION INCLUDES A WAIVER REQUEST FOR: Permit/Rush Fees: %Waiver Fees: Date of Payment: 2 t 5- ?­0 Date of Payment: Permit No. D S P'L V /_3 9 ' Waiver No. Phone- 907-343-7904 Distance: December 4, 2024 MOA Development Services, On-Site Water & Wastewater Program 4700 Elmore Rd Anchorage, AK 99507 Subject: Overlook Estates #3, Lot 20 – 27425 Wilde Circle Septic system design Dear On-Site Services Engineer: The owner of the above lot intends to build a new 4-bedroom home on the property, so we are submitting this permit application for the construction of a new well and septic system. The attached site plan identifies the location of the home as well as the proposed well, septic location and alternate site. No conflicts exist between this proposed system and any other well or septic system, whether on this lot or adjacent lots. The ground surface on the lot slopes toward the south moderately from the back of the lot at about a 10-15% slope. There are no slopes greater than 25% within 50 feet downslope of either the primary or alternate site. Contours are shown on the site plan showing the grade and direction of flow. Stormwater drainage will not impact this septic system. The new trench will be constructed parallel to the slope as much as possible. The trenches will be located uphill from the house, but the contractor is confident that he can install them deeper to avoid putting in a lift station. We have specified on the septic section that the maximum depth is 12’ to ensure separation to impermeables. Wells on this and adjacent lots are shown. The new system will be a minimum of 100’ from all wells and surface water, and more than 5’ away from the septic tank. The alternate site is located more than 6’ away. Please refer to the attached test hole logs, plan and profile pages for the septic design. If this design is followed, there will be no adverse impacts to adjacent properties. Sincerely, Benjamin Schiller, PE Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP241394, Curtis Townsend, 12/06/24 OVERLOOK ESTATES #3, LOT 20 C -� ALTERNATE SITE: LOT ZO (2) 60' LONG x 5' WIDE, 6" EFFECTIVE DEPTH ABSORPTION TRENCHES TH#1 LOT 19__. 1250-GAL r SEPTIC TANK 4-BDRM HOME C • . 2C0 FLOW DIVERTER VALVE SET TO DIVERT j TO UPPER TRENCH AND PROPOSED WELL ' l,(2 2� � CO MT FS TO -FLOW SPLITTER Wl 100' RADIUS r CO 4 CO 13.3 C ` CO (3)-40'-LONG x 5' WIDE, 6" EFFECTIVE ' CO MT DEPTH ABSORPTION TRENCHES CONFIRMATION TEST HOLE TO BE -- DUG PRIOR TO CONSTRUCTION LOT 41 a , E NG I N E EN I N G LEGEND Aw �p'��•'""' l��r CO - CLEANOUT SEPTIC PLAN 2C0 -DOUBLE CLEANOUT FCO- FOUNDATION CLEANOUT . % FS - FLOW SPLITTER VALVE �/ • Benja i Schiller j 0 50 100 MH - MANHOLE �+ �F'• CE 2592 ���� MT - MONITORING TUBE �tisrF�FaP :moo...FEET 1� ROfESS10N,`.�. 1 "=50' SV -SEPTIC VENT TH - TEST HOLE DEPTH (feet) 1 - 2 3 4 5 6 7 8 9 1 11 12 13 14 15 16 17 18 19 SOILS LOG AND PERCOLATION TEST LEGAL DESCRIPTION: OVERLOOK ESTATES #3, LOT 20 PERFORMED FOR: KOUROSH PARTOW DATE: 12/3/2024 PARCEL ID#: 067-231-33 TEST HOLE 1 NO WAS WATER ENCOUNTERED? - IF YES @ WHAT DEPTH? NONE DEPTH TO WATER AFTER MONITORING 12/30/24 DATE OF MONITORING DATE READING START TIME NET TIME (MINUTES) PTH TO WATER (INCHES) NET DROP (INCHES) 12/3 1 3:25 018 1 0 716 6 s 2 3:26 0:24 1 1s 7 0 6 0 3 3:27 0:26 116 71s 616 4 3:27 0:28 1 Ts 71s 616 5 3:28 0:29 1 Ts 7 0 616 6 3:29 0:30 10 71s 61s PERCOLATION RATE: 0.08 (MIN/INCH) COMMENTS: USCS SOIL CLASSIFICATION WAS VISUALLY DETERMINED SITE PLAN TECHNICIAN: J.OPHEIM OVERLOOK ESTATES #3, LOT 20 TYPICAL TRENCH SECTION (NO SCALE) NOTES: 1. GRADE AREA OVER TRENCH TO DRAIN AWAY 2. PROVIDE 3' OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2' WITH 2" OF INSULATION 3. CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY Benjamin Schiller CE 12592REGISTEREDPROFESSION A L E N GINEER 4" PERFORATED PVC (HOLES DOWN) DRAINFIELD ROCK 6" 6' 6" DESIGN FACTORS:SYSTEM REQUIREMENTS: 600 GPD PEAK FLOW PERK RATE: <1 MIN/IN APPLICATION RATE: 1 GPD/SF 5' WIDE TRENCH SYSTEM 1250-GAL SEPTIC TANK BOTTOM OF TRENCH: 7' BELOW GRADE (MAXIMUM OF 12') FLOW LINE ELEVATION: 6' 6" BELOW GRADE 600 GPD / 1 GPD/SF / 5' WIDE * 1.00 RED FACTOR [0.5' DEEP] = 120 LF TRENCH REQUIRED (120 LF SPECIFIED) GEOTEXTILE FABRIC 6" 12/4/24 PROVIDE ADDITIONAL FILL TO ACCOUNT FOR SETTLEMENT 5' 2' MOA APPROVED SAND Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP241394, Curtis Townsend, 12/06/24