Loading...
HomeMy WebLinkAboutCOSA Checklist (58)COSA Checklist.docx COSA Checklist Legal Description: HAMANN ADDN #1 BLOCK 1 LOT 7 Parcel ID: 050-611-27 If more than 1 well and/or septic system on lot, provide separate checklist. Structure served by this system ____ A. WELL DATA Well log is filed with Onsite (or attached) Date drilled 4/4/2000 Total depth 300 ft Cased to 20 ft (INTO BEDROCK) Sanitary seal is functioning correctly Wires are properly protected Casing height (above ground) 19 in. Date of flow test for COSA 12/4/24 Static water level at beginning of test 121 ft. Well production at time of test 0.37 gpm Water storage tank volume NONE* gallons Well disinfected for coliform test? Yes No Coliform bacteria is Negative Nitrate 0.285 mg/L Nitrate less than MRL (ND) Arsenic ug/L Arsenic less than MRL (ND) Collected by Date 12/4/24 Comments *Previous MOA record docs show water storage & there was none found – only one large and one small pressure tank located in the garage. SEE MOA low water production advisory. B. TANK DATA Measured operating fluid level in septic tank 47” Date of pumping 12/3/24 Required maintenance completed, if AWWTS Comments: C. LIFT STATION Required maintenance completed Age of lift station years Lift station material Comments: D. ABSORPTION FIELD DATA Which system tested (date installed) 9/6/2000 ALL standpipes present per record drawing Total measured depth from existing grade 6.6 ft (max) Measured depth to pipe invert from grade 3.3 ft (min) N/A – pressurized field. Per record drawings, field is insulated. Monitor tubes (MT) go to bottom of effective. (ED) If not, state depth into effective Presoaked required if (Required if house vacant or field not used for more than 30 days prior to date of test) Gallons introduced gallons date Any rejuvenation treatment (past 12 months) N If yes, enter date Adequacy test date 12/4/24 Results Pass Fluid depth prior to test 6 in Water added 450 gal New fluid depth 17 in Elapsed time 1440 min Final fluid depth 4 in Absorption rate 450 gpd FIELD STATUS – POST RECOVERY Effective depth (per record drawings) 36 in (MOA 3’ ED) Effective depth used 4 in (Final Fluid Depth) Effective depth (ED) remaining 32 in Comments/Deficiencies: Approximate total measured depths from existing grade. ED per elevation measured shots, visual observations, MOA records & appears approximate. COSA Checklist.docx E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well on lot) Septic Tank/Lift Station on Lot > 100’ Yes if No ft Neighboring Tank > 100’ Yes if No ft Absorption Field on Lot > 100’ Yes if No ft Neighboring Absorption Fields > 100’ Yes if No ft Community Sewer Main > 75’ Yes if No ft Community Sewer Manhole/Cleanout > 100’ Yes if No ft Private Sewer/Septic Line > 25’ Yes if No ft Holding Tank > 100’ Yes if No ft Animal Containment > 50’ Yes if No ft Manure/Animal Excreta Storage > 100’ Yes if No ft N/A – Served by Community Well (not on lot) or Public Water From Septic/Holding Tank and Absorption Field(s) on Lot to: (Please enter distances if less than required) Building Foundations > 10’ Yes if No ft Tank to Property Line > 5’ Yes if No ft Field to Property Line > 10’ Yes if No ft Water Main > 10’ Yes if No ft Water Service Line > 10’ Yes if No ft Surface Water > 100’ Yes if No ft Wells on Adjacent Lots: Private Wells > 100’ Yes if No ft Community Wells > 200’ Yes if No ft If tank or field is under driveway comment below F. ENGINEER’S COMMENTS G. CERTIFICATION & STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines, indicates that the on-site water supply and/or wastewater disposal system appears to comply with applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation, unless noted otherwise. Name of Firm FIRST WATER CONSULTING Phone 907-350-9566 Engineer’s Printed Name CURTIS HUFFMAN, PE Date 12/10/2024 Comments: This investigation was completed in compliance with MOA guidelines, regulations, and best industry practices / methods. The assessment of the condition of the well and septic applies only to the conditions as of the day tested. The flow and absorption rates may change due to subsurface conditions that may not be observed from the surface, changes in land use, local soil characteristics, groundwater levels that may fluctuate during the year, quality of construction (workmanship & materials), the water usage of the family being served by the system and maintenance. The operational life of all well and septic systems are subject to these various and dynamic characteristics and are outside the control of the evaluator of the well and septic system. Therefore, any or NO estimate of how long a system will function satisfactory for current or future occupants or guarantee that no unseen encroachments, deficiencies or discrepancies exist can be given by First Water Consulting & 12/10/24