COSA Checklist
Legal Description: HAMANN ADDN #1 BLOCK 1 LOT 7 Parcel ID: 050-611-27
If more than 1 well and/or septic system on lot, provide separate checklist. Structure served by this system ____
A. WELL DATA
Well log is filed with Onsite (or attached)
Date drilled 4/4/2000 Total depth 300 ft
Cased to 20 ft (INTO BEDROCK)
Sanitary seal is functioning correctly
Wires are properly protected
Casing height (above ground) 19 in.
Date of flow test for COSA 12/4/24
Static water level at beginning of test 121 ft.
Well production at time of test 0.37 gpm
Water storage tank volume NONE* gallons
Well disinfected for coliform test? Yes No
Coliform bacteria is Negative
Nitrate 0.285 mg/L Nitrate less than MRL (ND)
Arsenic ug/L Arsenic less than MRL (ND)
Collected by Date 12/4/24
Comments *Previous MOA record docs show water storage & there was none found – only one large and one small
pressure tank located in the garage. SEE MOA low water production advisory.
B. TANK DATA
Measured operating fluid level in septic tank 47”
Date of pumping 12/3/24
Required maintenance completed, if AWWTS
Comments:
C. LIFT STATION
Required maintenance completed
Age of lift station years
Lift station material
Comments:
D. ABSORPTION FIELD DATA
Which system tested (date installed) 9/6/2000
ALL standpipes present per record drawing
Total measured depth from existing grade 6.6 ft (max)
Measured depth to pipe invert from grade 3.3 ft (min)
N/A – pressurized field.
Per record drawings, field is insulated.
Monitor tubes (MT) go to bottom of effective. (ED)
If not, state depth into effective
Presoaked required if
(Required if house vacant or field not used for more
than 30 days prior to date of test)
Gallons introduced gallons date
Any rejuvenation treatment (past 12 months) N
If yes, enter date
Adequacy test date 12/4/24
Results Pass
Fluid depth prior to test 6 in
Water added 450 gal
New fluid depth 17 in
Elapsed time 1440 min
Final fluid depth 4 in
Absorption rate 450 gpd
FIELD STATUS – POST RECOVERY
Effective depth (per record drawings) 36 in (MOA 3’ ED)
Effective depth used 4 in (Final Fluid Depth)
Effective depth (ED) remaining 32 in
Comments/Deficiencies: Approximate total measured depths from existing grade. ED per elevation measured shots,
visual observations, MOA records & appears approximate.
COSA Checklist.docx
E. SEPARATION DISTANCES
From Private Well on Lot to: (Please enter distances if less than required or if community well on lot)
Septic Tank/Lift Station on Lot > 100’
Yes if No ft
Neighboring Tank > 100’ Yes if No ft
Absorption Field on Lot > 100’ Yes if No ft
Neighboring Absorption Fields > 100’
Yes if No ft
Community Sewer Main > 75’ Yes if No ft
Community Sewer Manhole/Cleanout > 100’
Yes if No ft
Private Sewer/Septic Line > 25’ Yes if No ft
Holding Tank > 100’ Yes if No ft
Animal Containment > 50’ Yes if No ft
Manure/Animal Excreta Storage > 100’
Yes if No ft
N/A – Served by Community Well (not on lot) or Public Water
From Septic/Holding Tank and Absorption Field(s) on Lot to: (Please enter distances if less than required)
Building Foundations > 10’ Yes if No ft
Tank to Property Line > 5’ Yes if No ft
Field to Property Line > 10’ Yes if No ft
Water Main > 10’ Yes if No ft
Water Service Line > 10’ Yes if No ft
Surface Water > 100’ Yes if No ft
Wells on Adjacent Lots:
Private Wells > 100’ Yes if No ft
Community Wells > 200’ Yes if No ft
If tank or field is under driveway comment below
F. ENGINEER’S COMMENTS
G. CERTIFICATION & STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based
on procedures outlined in the Certificate of On-Site Systems Approval Guidelines, indicates that the on-site water
supply and/or wastewater disposal system appears to comply with applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation, unless noted otherwise.
Name of Firm FIRST WATER CONSULTING Phone 907-350-9566
Engineer’s Printed Name CURTIS HUFFMAN, PE Date 12/10/2024
Comments: This investigation was completed in compliance with MOA guidelines, regulations,
and best industry practices / methods. The assessment of the condition of the well and septic
applies only to the conditions as of the day tested. The flow and absorption rates may change
due to subsurface conditions that may not be observed from the surface, changes in land use,
local soil characteristics, groundwater levels that may fluctuate during the year, quality of
construction (workmanship & materials), the water usage of the family being served by the
system and maintenance. The operational life of all well and septic systems are subject to
these various and dynamic characteristics and are outside the control of the evaluator of the
well and septic system. Therefore, any or NO estimate of how long a system will function satisfactory
for current or future occupants or guarantee that no unseen encroachments, deficiencies or
discrepancies exist can be given by First Water Consulting &
12/10/24