HomeMy WebLinkAboutSPRUCE TERRACES LOT 10Spruce Terraces Lot 10 t; A( S Vj 0 M T -A lfA � R Municipality of Anchorage On-Site Water and Wastewater Section • (907) 343-7904 Page 1 of 1 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP251012 PID Number: 020-044-15 Dwelling: X Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project:* New ❑ Upgrade Name Spinell Homes, Inc. ABSORPTION FIELD Deep Trench ❑ Wide Trench ❑ Bed ❑ Mound Site Address 6942 AVALANCHE CIRCLE ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade P4 1.2 GPD/SFJ 10 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade 4 Ft.6 Gravel depth beneath pipe Ft. Subdivision Block Lot SPRUCE TERRACES 10 Fill added above original grade 0.7-3.6 (+/-) Ft. Gravel length 48 Ft. Township Range Section Gravel width 2.5 Ft. Beds: Number of Lines Distance between lines Ft. SEPARATION DISTANCES To Septic Absorption Lift Station Holding j Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Tank Line 540 Ftp 1 Ft. Well 100'+ 100'+ ! NA NA 25'+ TANK N Septic ElS.T.E.P. ElHolding ElOther Manufacturer GREER Capacity 1250 Gal. Surface Water 100'+ 100'+ NA NA Material Number of compartments Lot Line 5'+ 10'+NA NA NA HDPE (DEEP BURIAL) 2 Foundation 101+ 10'+ NA NA LIFT STATION Manufacturer Capacity Remarks Gal. Alarm location Electrical installed by Installer PIPE MATERIAL House to tank D3034 Tank to D3034 drainfield POMRANING EXCAVATION, LLC. Drainfield D3034 CO/MTD3034 Inspector PES BENCH MARK (Assumed elevation) 100.0 ft Inspdection v, 05/05/25 05/05/25 Location and description 2nd 311 05/06/25 411 07/10/25 Back Door Threshold (See Site Plan) ON-SITE WATER AND WASTEWATER SECTION APPROVAL Engineer's Stamp A1.41kklt Conditional Approval: Date,� �E 0F. 49TH 5,e1 R� cnrioneP Septic System CE 8149y� Approved J Dat �-ROFESSOt�P-.► ®�����`�~ te: this approval does not include well permit requirements. (Rev 05/02/18) TEST HOLE 10 PERFORMED: 10/13/2020 HOLE OBS. DRY: 10/27/2020 73.7 93.1 92.9 3 4 2 1 MT1 MT1 BOH OR 7 6 5 8 9 10 CO1 CO1 FG (E): 97.3 TEST HOLE 10 OG/FG: 89.7 OG (W): 93.7± 1250 GAL GREER POLY TANK *OG/FG: 97.7 FC DCO GW/SM 11 12 13 T2 T1 14 15 16 OG (E): 96.6±DRAIN ROCK 6" ABOVE PIPE INV 4"Ø DRAIN PIPE FILTER FABRIC 92.7 92.7 86.7 86.7 6.0' DRAIN ROCK 4.0* *PER MEASUREMENTS PROVIDED TO PES BY INSTALLER AS INSPECTED BY INSTALLER ON 04/14/2026. PA N N O N E E N G S V C , L L C ( C . I . 1 0 8 8 ) KT G / L J C RE C O R D D R A W I N G SP R U C E T E R R A C E S L O T 1 0 SP I N E L L H O M E S , I N C . SI T E : 6 9 4 2 A V A L A N C H E C I R C L E AN C H O R A G E , A K 04 / 1 4 / 2 0 2 6 02 0 - 0 4 4 - 1 5 OS P 2 5 1 0 1 2 AC P RE V 1 : 0 4 / 2 2 / 2 0 2 6 ST E V E N R . P A N N O N E CE - 8 1 4 9 R E GI STEREDPROFES SI O N A L E N GINEER 04 / 1 5 / 2 0 2 6 PR O F I L E NT S 2 O F 2 SCALE: NTS SEPTIC SYSTEM PROFILEI Av a l a n c h e C i r c l e 10' T & E E A S E M E N T NO WELL OR SEPTIC W/IN 100 SEPTIC A R E A >200' VACANT UNDEVELOPED LOT LOT 10 LOT 9 LOT 8 LOT 11 10' T & E E A S E M E N T 4 BR SFD (N) 97 5 97 0 96 5 DRIVEWAY 12.0 98 0 9.1 INSTALLED ABSORPTION FIELD (N) 48LF x 2.5'W x 6.0'E.D., 10.0'T.D. INSTALLED W/CO & MT AT EACH END INSTALLED 1250gal SEPTIC TANK (N) INSTALLED W/FC BEFORE & DCO AFTER TH-10 FC T2 T1DCO CO1 MT1 CO2 MT2 RESERVE AREA (NIC) ASSUMED ROUTE WATER SERVICE LINE (BY OTHERS) APPROXIMATE WATER SERVICE BY OTHERS B A BM APPROX. SHOULDER OF FILL SLOPE (YARD GRADED FOLLOWING/DURING CONSTRUCTION) 12.8 PA N N O N E E N G S V C , L L C ( C . I . 1 0 8 8 ) KT G / L J C RE C O R D D R A W I N G SP R U C E T E R R A C E S L O T 1 0 SP I N E L L H O M E S , I N C . SI T E : 6 9 4 2 A V A L A N C H E C I R C L E AN C H O R A G E , A K 04 / 1 4 / 2 0 2 6 02 0 - 0 4 4 - 1 5 OS P 2 5 1 0 1 2 AC P ST E V E N R . P A N N O N E CE - 8 1 4 9 R E GI STEREDPROFES SI O N A L E N GINEER 04 / 1 5 / 2 0 2 6 SI T E P L A N 1" = 5 0 ' 1 O F 2 A B FC 48.8 15.4 T1 49.9 35.3 T2 52.2 39.3 DCO 55.5 44.1 MT1 60.8 50.1 CO1 59.1 48.7 MT2 99.5 92.3 CO2 101.0 93.0 RECORD DRAWING THIS RECORD DRAWING REPRESENTS THE AS-BUILT CONDITION OF THE PROPERTY IMPROVEMENTS DESCRIBED ABOVE. THE DRAWING AND ANY OTHER SUBSEQUENT ATTACHED OR INCLUDED INFORMATION IS BASED ON PERIODIC VISUAL OBSERVATION BY A REPRESENTATIVE OF PES ALONG WITH NOTES, PHOTOS, AND OTHER INFORMATION PROVIDED BY THE INSTALLER OF THE SYSTEM. THE INFORMATION PROVIDED IN THE RECORD DRAWING APPEARS REASONABLE AND REPRESENTS THAT THE PROJECT WAS DESIGNED AND CONSTRUCTED IN GENERAL CONFORMANCE OF 18 AAC 72, THE ADEC ONSITE WASTEWATER SYSTEM INSTALLATION MANUAL, AND AMC 15.65 WHERE APPLICABLE. PES SHALL NOT BE HELD LIABLE FOR SYSTEM DEFICIENCIES WHICH FALL OUTSIDE THE SCOPE OF THE REQUIRED VISUAL OBSERVATIONS OR SUBSEQUENT OBSERVATIONS IF REQUESTED BY THE INSTALLER. SEPTIC SYSTEM INSTALLERS ARE TRAINED AND APPROVED BY THE MUNICIPALITY OF ANCHORAGE AND OR ADEC AS APPLICABLE. INSTALLERS ARE RESPONSIBLE FOR CONSTRUCTING THE SEPTIC SYSTEM AS DESIGNED AND ENSURING THEIR WORK CONFORMS TO THE CODES AND POLICIES STATED ABOVE. DESIGN PARAMETERS PRIMARY/RESERVE SEPTIC SYSTEM NO. BEDROOM: 4 (600 gpd) TANK SIZE: 1250gal MoA APPROVED TANK PERC RATE: 3.7 MPI SOIL RATING: 1.2 GPD/SF AREA RQD: 500 SF SYS. TYPE: DEEP TRENCH 6.0' E.D. MIN LENGTH: 42 LF USED: 48LF x 2.5'W x 6.0' E.D x 10.0' T.D. TOTAL AREA: 576 SF ABBREVIATIONS CO CLEAN OUT NO. DCO DOUBLE CLEANOUT DV DIVERTER VALVE (E)EXISTING FC FOUNDATION CLEANOUT FS FLOW SPLITTER MT MONITOR TUBE NO. MH MANHOLE NO. (N)NEW NIC NOT IN CONTRACT (P)PROPOSED TH TEST HOLE TYP TYPICAL NEW SEPTIC WATER LINE / WELL RADIUS ESMT/SETBACK STREAM/DRAINAGE WAY CENTERLINE FLOW PATH MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Wastewater Disposal System Permit Permit Number: OSP251012 Work Type: Septic Initial Tax Code Number: 02004415000 Site Legal Address: SPRUCE TERRACES LOT 10 G:3239 Site Mailing Address: 6942 AVALANCHE CIR, Anchorage Owner: MISSION HILLS LLC Design Engineer: PANNONE ENGINEERING SERVICES This permit is for the construction of: Effective Date: Expiration Date Lot Size in Sq Ft: Total Bedrooms: 2/21/2025 2/21/2026 54525 Q Disposal Field D Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing -Recoive"y: S ue ok -tv ASS Date: Issued By: (tet/ Date:y� _ 4 MUNICIPALITY OF Development Services Department On -Site Water & Wastewater Section Parcel I.D. 020-044-15 ON-SITE SEPTIC/WELL PERMIT APPLICATION Property owner(s) Mission Hills LLC Mailing address Site address 6942 Avalanche Circle Legal description Spruce Terraces, Lot 10 Number of Bedrooms 4 Engineering Firm Pannone Engineering Services, LLC Day phone Building Permit Number AZ 'j - 3170 Not Applicable R APPLICATION IS FOR: (Z all that apply) Absorption Field F] R D Septic Tank Holding Tank Privy Well APPLICATION IS AN: Initial Upgrade ❑ Renewal ❑ THIS APPLICATION INCLUDES A WAIVER REQUEST FOR: Permit/Rush Fees: Date of Payment: 57 Permit No. 05P25/0121 Waiver Fees: Date of Payment: Waiver No. Phone: 907-343-7904 Distance: Pannone Engineering Services LLC Steven R. Pannone, Principal Registered Professional Engineer E‐mail: steve@panengak.com Mailing: P.O.Box 1807, Palmer, AK 99645 Telephone: (907) 745‐8200   FAX: (907) 745‐8201 Municipality of Anchorage Development Services Department On‐Site Water & Wastewater Program 4700 Elmore Road Anchorage, Alaska Subject:   Spruce Terraces, Lot 10          Septic System Permit Request This is a design narrative for a permit to install a new septic system on the subject property. The proposed system will serve a proposed four‐bedroom (4) house.  This lot and surrounding lots are served by a community water system. There are no wells within 200’ of this system. 1. Soils: A test hole was performed on this lot by Pannone Engineering Services, LLC on 10/13/2020. Groundwater was not observed during the excavation of the test hole, and bedrock was not encountered. No groundwater was observed in the test hole monitor tube after 7‐days. The test hole on lot 10 was found to have a percolation test result of 3.7 minutes per inch. 27 test holes were performed in this subdivision by PES for the approval of the subdivision, and more were performed during the design of septic systems on lots in the subdivision.  No groundwater has been observed in the subdivision.  Bedrock was not encountered anywhere in the subdivision. The test holes in the area were all found to have a percolation of less than 5 MPI, some less than 1 MPI. See soils logs for subdivision, S12577.  The test hole on lot 10 was performed further to the north than the system will actually be installed.  We are using surrounding test holes as a justification. Based on the results of the surrounding percolation tests and known soil types in the area, per 15.65.210 C; a conservative application rate of 1.2 gallons/day/square feet was used for a conventional wastewater system. 2. Soil Absorption System Design. a. See Sheet 1 of the design package. 3. Surface Water: There is no surface water within 100 feet of the proposed septic tank and drain field. 4. Topography: See attached site plan for area topography. There are no steep slopes in the area of the drain field. 5. Drawing Markings: The Drawings are marked “For MOA Review Only”. When written notification that the review is complete and no further comments are received from MoA On‐Site Department, the note will be removed and “For Construction” drawings will be issued. The proposed installation will not affect the future development of this or the surrounding lots. If you have any questions or concerns, please contact me at (907) 745‐8200. Sincerely, SRP Steven R. Pannone, P.E. F. ASCE Owner/Civil Engineer 6 February 2025 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP251012, Deb Wockenfuss, 02/21/25 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP251012, Deb Wockenfuss, 02/21/25 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP251012, Deb Wockenfuss, 02/21/25 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP251012, Deb Wockenfuss, 02/21/25 MUNICIPALITY OF ANCHORAGE Development Services Department Phone: (907)343-7904 On -Site Water & Wastewater Section Fax: (907)343-7997 Parcel ID 020 -044-15 Certificate of On -Site Systems Approval OSC261091 Expiration Date: 7/10/2026 Legal description SPRUCE TERRACES LT 10 site address 6942 AVALANCHE CIR Current property owner(s) SPINELL HOMES INC X The On-site system(s) is/are approved for 4 bedrooms Conditional approval for bedrooms, with the following stipulations: Comments or conditions: ents By: - Original Certificate Date: 4/22/2026 This Certificate of On -Site Systems Approval (COSA) is intended to demonstrate the subject system(s) is/are in substantial compliance with municipal code. The Municipality of Anchorage, Development Service Department (DSD) issues COSAs based upon representations provided by an independent professional engineer. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's submittal. ATTACHMENTS: COSA Checklist X Well Flow Advisory Absorption Field Advisory Nitrate Advisory Tank Age Advisory Arsenic Advisory Other MUNICIPALITY OF ANCHORAGE Development Services Department Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Certificate of On -Site Systems Approval Application 1. GENERAL INFORMATION Parcel I.D. 020-044-15 Complete legal description Spruce Terraces X10 Location (site address) 6942 Avalanche Cir Current property owner(s) Spinell Homes, Inc.. 2. ON-SITE SYSTEMS SIZED FOR 4 BEDROOMS Day phone 3. TYPE OF WATER SUPPLY: F-1 Private Well serving # dwelling units ❑ Other Non-public well as regulated by MOA ❑ Water Storage FEW Community Well or Public 4. TYPE OF WASTEWATER DISPOSAL: NJ Private Septic F Private Septic serving 2 dwelling units ❑ Holding Tank R Community Septic or Public Sewer 5. SEPTIC TANK: F-1 Steel RE Plastic R Concrete F] Fiberglass Age <1 - See advisory if steel or fiberglass older than 20 years 6. ABSORPTION FIELD: n AWWTS n Bed FNJ Deep Trench FJ Wide Trench n Seepage Pit Waiver request for: Distance: Expedited review requested: ❑ By applying for this entitlement, this property is subject to inspection by municipal On-site staff to verify the accuracy of the information provided. COSA Fee $ Waiver Fee $ Date of Payment Date of Payment COSA # 9, Waiver # COSA Application—Ap2025,doc COSA Checklist_May2025.docx COSA Checklist Legal Description: Parcel ID: If more than 1 well and/or septic system on lot, provide separate checklist. Structure served by this system ____ A. WELL DATA Well log is filed with Onsite (or attached) Date drilled Total depth ft Cased to ft Sanitary seal is functioning correctly Wires are properly protected Casing height (above ground) in. Date of flow test for COSA Static water level at beginning of test ft. Well production at time of test gpm Water storage tank volume gallons Well disinfected for coliform test? Yes No Coliform bacteria is Negative Nitrate mg/L Nitrate less than MRL (ND) Arsenic ug/L Arsenic less than MRL (ND) Collected by Date Comments __________________________________________________________________________________ B. TANK DATA Measured operating fluid level in septic tank Date of pumping Required maintenance completed, if AWWTS Comments: C. LIFT STATION Required maintenance completed Age of lift station years Lift station material Comments: D.DISPOSAL FIELD DATA Which system tested (date installed) ALL standpipes present per record drawing Total measured depth from grade ft (max) Measured depth to pipe invert from grade ft (min) N/A – pressurized field. Per record drawings, field is insulated. Monitor tubes go to bottom of effective. If not, state depth into effective Presoaked required if (Required if house vacant or field not used for more than 30 days prior to date of test) Gallons introduced gallons date Any rejuvenation treatment (past 12 months) If yes, enter date Adequacy test date Results Pass Fluid depth prior to test in Water added gal New fluid depth in Elapsed time min Final fluid depth in Absorption rate gpd FIELD STATUS – POST RECOVERY Effective depth (per record drawings) in Effective depth used in Effective depth remaining in Comments/Deficiencies: E. SEPARATION DISTANCES From Well on Lot to: (Please enter distances if less than required) Septic Tank/Lift Station on Lot > 100’ Yes if No ft Neighboring Tank > 100’ Yes if No ft Disposal Field on Lot > 100’ Yes if No ft Neighboring Disposal Fields > 100’ Yes if No ft Sewer Line/Main > 100’ Yes if No ft Sewer Manhole/Cleanout > 100’ Yes if No ft Sewer Service/Septic Line > 25’ Yes if No ft Holding Tank > 100’ Yes if No ft Animal Containment > 50’ Yes if No ft Manure/Animal Excreta Storage > 100’ Yes if No ft N/A – Served by Community Well (not on lot) or Public Water From Septic/Holding Tank and Disposal Field(s) on Lot to: (Please enter distances if less than required) Tank to Foundation > 10’ Yes if No ft Field to Foundation > 10’ Yes if No ft Tank to Property Line > 5’ Yes if No ft Field to Property Line > 10’ Yes if No ft Water Main/Service Line > 10’ Yes if No ft Surface Water > 100’ Yes if No ft Wells on Adjacent Lots: Wells > 100’ Yes if No ft Community Wells > 200’ Yes if No ft If tank or field is under driveway comment below F.ENGINEER’S COMMENTS G.CERTIFICATION & STATEMENT OF INSPECTION BY ENGINEER Phone Name of Firm Engineer’s Printed Name COSA Checklist_May2025.docx Date As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines, indicates that the on-site water supply and/or wastewater disposal system appears to comply with applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation, unless noted otherwise. In conducting an adequacy test, I attempt to provide a thorough, conscientious engineering analysis of the system in accordance with ADEC & MOA guidelines and regulations. The reported results describe the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soil condition, ground water levels that may fluctuate during the years, and the water usage of the people served by the system. These conditions are outside the control of the evaluator of this system. All systems eventually fail, and satisfactory test results do not guarantee future performance if the system, nor do they guarantee that there are no hidden defects of encroachments. Therefore, we cannot provide any warranty of future performance, nor can we estimate the remaining life of the system. The content of this report is for the sole benefit of the owner listed above. AsBuilt 10/24/25 Feet 0 50 100