HomeMy WebLinkAboutSPRUCE TERRACES LOT 10Spruce Terraces
Lot 10
t; A( S Vj 0 M T -A lfA � R
MUNICIPALITY OF ANCHORAGE
On -Site Water & Wastewater Program
PO Box 196650 4700 Elmore Road
Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997
http://www.muni.org/onsite
On -Site Wastewater Disposal System Permit
Permit Number: OSP251012
Work Type: Septic Initial
Tax Code Number: 02004415000
Site Legal Address: SPRUCE TERRACES LOT 10 G:3239
Site Mailing Address: 6942 AVALANCHE CIR, Anchorage
Owner: MISSION HILLS LLC
Design Engineer: PANNONE ENGINEERING SERVICES
This permit is for the construction of:
Effective Date:
Expiration Date
Lot Size in Sq Ft:
Total Bedrooms:
2/21/2025
2/21/2026
54525
Q Disposal Field D Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
-Recoive"y: S ue ok -tv ASS Date:
Issued By: (tet/ Date:y� _
4
MUNICIPALITY OF
Development Services Department
On -Site Water & Wastewater Section
Parcel I.D. 020-044-15
ON-SITE SEPTIC/WELL PERMIT APPLICATION
Property owner(s) Mission Hills LLC
Mailing address
Site address 6942 Avalanche Circle
Legal description Spruce Terraces, Lot 10
Number of Bedrooms 4
Engineering Firm Pannone Engineering Services, LLC
Day phone
Building Permit Number AZ 'j - 3170 Not Applicable R
APPLICATION IS FOR:
(Z all that apply)
Absorption Field F]
R
D
Septic Tank
Holding Tank
Privy
Well
APPLICATION IS AN:
Initial
Upgrade
❑
Renewal
❑
THIS APPLICATION INCLUDES A WAIVER REQUEST FOR:
Permit/Rush Fees:
Date of Payment: 57
Permit No. 05P25/0121
Waiver Fees:
Date of Payment:
Waiver No.
Phone: 907-343-7904
Distance:
Pannone Engineering Services LLC
Steven R. Pannone, Principal
Registered Professional Engineer
E‐mail: steve@panengak.com
Mailing: P.O.Box 1807, Palmer, AK 99645
Telephone: (907) 745‐8200 FAX: (907) 745‐8201
Municipality of Anchorage
Development Services Department
On‐Site Water & Wastewater Program
4700 Elmore Road
Anchorage, Alaska
Subject: Spruce Terraces, Lot 10
Septic System Permit Request
This is a design narrative for a permit to install a new septic system on the subject property. The proposed system will serve a
proposed four‐bedroom (4) house. This lot and surrounding lots are served by a community water system. There are no wells
within 200’ of this system.
1. Soils:
A test hole was performed on this lot by Pannone Engineering Services, LLC on 10/13/2020. Groundwater was not observed
during the excavation of the test hole, and bedrock was not encountered. No groundwater was observed in the test hole
monitor tube after 7‐days. The test hole on lot 10 was found to have a percolation test result of 3.7 minutes per inch. 27 test
holes were performed in this subdivision by PES for the approval of the subdivision, and more were performed during the
design of septic systems on lots in the subdivision. No groundwater has been observed in the subdivision. Bedrock was not
encountered anywhere in the subdivision. The test holes in the area were all found to have a percolation of less than 5 MPI,
some less than 1 MPI. See soils logs for subdivision, S12577. The test hole on lot 10 was performed further to the north than
the system will actually be installed. We are using surrounding test holes as a justification. Based on the results of the
surrounding percolation tests and known soil types in the area, per 15.65.210 C; a conservative application rate of 1.2
gallons/day/square feet was used for a conventional wastewater system.
2. Soil Absorption System Design.
a. See Sheet 1 of the design package.
3. Surface Water:
There is no surface water within 100 feet of the proposed septic tank and drain field.
4. Topography:
See attached site plan for area topography. There are no steep slopes in the area of the drain field.
5. Drawing Markings: The Drawings are marked “For MOA Review Only”. When written notification that the review is
complete and no further comments are received from MoA On‐Site Department, the note will be removed and “For
Construction” drawings will be issued.
The proposed installation will not affect the future development of this or the surrounding lots.
If you have any questions or concerns, please contact me at (907) 745‐8200.
Sincerely,
SRP
Steven R. Pannone, P.E. F. ASCE
Owner/Civil Engineer
6 February 2025
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP251012, Deb Wockenfuss, 02/21/25
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP251012, Deb Wockenfuss, 02/21/25
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP251012, Deb Wockenfuss, 02/21/25
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP251012, Deb Wockenfuss, 02/21/25