HomeMy WebLinkAboutUS SURVEY 3202 LT 1 T10N R1W SEC 10U SURVEY 3202
Lot 1 ION Rlw SEC
ce
t:,qs Lois me meAwm]
MUNICIPALITY OF ANCHORAGE
On -Site Water & Wastewater Program
PO Box 196650 4700 Elmore Road
Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997
http://www.muni.org/onsite
On -Site Wastewater Disposal System Permit
Permit Number: OSP251068
Work Type: Septic Initial
Tax Code Number: 09002223000
Site Legal Address: US SURVEY 3202 LT 1 T10N R1W SEC 10 GA760
Site Mailing Address: 362 KONIKSON RD, Indian
Owner: MAYER ANN MARIE
Design Engineer: CREWDSON ENGINEERING, LLC
This permit is for the construction of:
Effective Date:
Expiration Date:
Lot Size in Sq Ft:
Total Bedrooms:
4/24/2025
4/24/2026
R1 Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
Received By: / A 7�O C �Lf SO Date:
Issued By: Date: Z 2
2
MUNICIPALITY OF
"J
Development Services Department
On -Site Water & Wastewater Section
ON -SITE SEPTIC/WELL PERMIT APPLICATION
Parcel I.D. 090-022-23
Property owner(s) Ann Marie Mayer
Phone: 907-343-7904
Day phone 907-351-1792
Mailing address 2448 Ronny Place, Anchorage, AK 99508
Site address 352 Konikson Rd., Bird Creek
Legal description US Survey 3202, Lot 1, T1 ON R1 W S 10
Number of Bedrooms 2
Engineering Firm Crewdson Engineering
Building Permit Number
Not Applicable RN
APPLICATION IS FOR: APPLICATION IS AN:
(Z all that apply)
Absorption Field
RX Initial RX
Septic Tank
RX Upgrade R
Holding Tank
R Renewal ❑
Privy
❑
Well
❑
THIS APPLICATION INCLUDES A WAIVER REQUEST FOR:
STEP tank to well
Distance: 62 1
Permit/Rush Fees: 59.5- Waiver Fees: _M/
Date of Payment: 3 L-2, 5 Zo z 5 Date of Payment: z.S—
Permit No. 0C) PZ 5JOG 0 Waiver No.. 05 VZ 510 I _G7
James Jay Crewdson, P.E
Email: CELLC.1@outlook.com
Cell/Text: (907) 280‐9493
April 23, 2025
Onsite Reviewer
Municipality of Anchorage
On‐site Water & Wastewater Program
4700 Elmore Road
Anchorage, AK 99519‐6650
Reference: US Survey 3202, Lot 1
Septic System Design
Design Narrative, and
62‐foot STEP Tank to Well Separation Distance Waiver Request
Design: The 2‐bedroom home is currently served by a failing undocumented septic system that is at least
occasionally in shallow groundwater. The proposed design calls for it to be decommissioned in accordance
with the code.
Although much of the property has greater than 60 minute‐per‐inch soils and/or shallow groundwater,
suitable soils with excellent percolation and no groundwater were found at a higher location on the
property. Soils Log TH1 records an SP with Silt soil layer between 6.6‐feet and 9‐feet below ground level
that percolates at 2.9‐mpi, and an SM layer between 9‐feet and 16‐feet below ground level that
percolates in the 6‐mpi to 15‐mpi range. The proposed Wide trench (0.5EDx5Wx50L, 7TD) is located
near the toe of a 33% slope and complies with the following AMC 15.65.210 steep slope requirements:
AMC 15.65.210.B4 Subsections:
a: The 33% slope is within the required 25% minimum slope and 46% maximum slope,
a.i: The bottom of the upgradient side of the drainfield is 9‐feet above the bottom of the soils test hole,
a.ii: The trench does not exceed 60‐inches in width,
a.iii: The drainfield distribution pipe varies between 6‐feet to 6.5‐feet below the adjacent driveway
surface, which has been in place for several decades and is very stable. The slope beyond the driveway,
within 50‐feet down gradient of the drainfield, is vegetated with large old‐growth Sitka spruce trees.
a.iv: The distribution pipe invert is 6.5‐feet below the top of the natural organic surface,
a.v: The disposal field is a minimum of 100‐feet up‐gradient from any slope exceeding 46%,
b and c: The percolation rate is 2.9‐mpi, so these subsections dont apply.
The drainfield is higher than the house and will require an effluent lift pump. A camera/transmitter was
used to locate the sewer line inside the house with the hope of using a lift pump in that location.
Unfortunately, the sewer line was found to be about 3‐feet under the garage floor slab running parallel
to a structural interior wall founded on a roughly 12‐inch‐thick thickened slab foundation. This puts the
sewer line about 2‐feet vertically lower than and 1‐foot horizontally away from the bottom of the
structural footing. Due to the structural complexity, risk, and danger involved removing the garage floor
PO Box 671389 ● 18368 Amonson Road ● Chugiak, Alaska 99567
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP251068, Curtis Townsend, 04/24/25
Page 2 of 3
Date: April, 23, 2025
Subject: US Survey 3202, Lot 1
PO Box 671389 ● 18368 Amonson Road ● Chugiak, Alaska 99567
slab and digging 5‐feet to 6‐feet lower than the structural footing to install a lift station, it was decided
best to use a STEP tank outside the house. Furthermore, locating the lift station in the garage puts it less
than 30‐feet from the well, providing much less protection for the well and subject aquifer than the
requested separation distance for the STEP tank. In short, the proposed STEP tank to well separation is
more protective of the public health and subject aquifer than installing a lift station inside the house.
The proposed STEP tank will require a separation distance waiver to the well. Although the plan is to
locate the tank as far from the well as possible, an old soils test hole monitoring tube within 20‐feet of
the proposed STEP tank location shows groundwater to be fluctuating between 6.5‐feet to 8.5‐feet below
ground level. The design seeks to ensure the STEP tank will not be too deep in groundwater by keeping
the gravity line as short as possible, while also providing satisfactory protection for the well.
62‐foot STEP Tank to Well Waiver Request: The proposed design locates the STEP tank greater than 62‐
feet from the private onsite water well, which is on the opposite side of the house from the well. It is
lower than the well, making it nearly impossible for a sewage spill to reach the well on the ground surface.
Entrance into the house both on foot or by vehicle is also between the tank and well, which will allow any
sewage spills on the ground surface to be easily monitored.
A well log does not appear to be available, but a recent well pump installation invoice notes the well depth
is 55‐feet and the static water level is 31‐feet (see Appendix A). Thus, the aquifer at the wells location
has approximately 10‐psi pressure [(55‐31) x 0.43 psi/ft] on it, indicating the aquifer is confined and very
unlikely to be polluted from infiltration of onsite sewage spills and/or leaks. A local aquifer study was
completed to extrapolate the likely soil strata for the subject property and compare static water levels to
determine the likelihood of the wells in this area tend to be confined of not. The findings indicate the two
closest wells with complete well logs are considered confined, further justifying the likelihood that the
subject well is confined too. (see Appendix A).
The well water was recently tested, which E. Coli and Total Bacteria was found to be Negative, and
Total Nitrate/Nitrite was found to be 0.428‐mgL. Both values are very low, indicating the well is not
influenced by either the existing failed undocumented septic system and/or the relatively shallow
groundwater the existing septic system is submerged in, further demonstrating that the subject aquifer is
confined and protected from onsite shallow sources of pollution. If the subject aquifer wasnt confined,
the lab results for E. Coli and Total Bacteria would be much more likely be Positive, and Total
Nitrate/Nitrite might be found to be elevated above the COSA required 5‐mgL threshold that requires
additional well testing. In short, the lab results indicate the aquifer is not under the influence of shallow
groundwater and/or the existing septic system.
Additionally, the HDPE plastic STEP tank is very unlikely to ever develop leaks from corrosion, and will also
have a high‐water alarm system in accordance with the code. In short, given the details of the proposed
installation and the multiple mitigating factors, the requested separation distance will be protective of
the public health and the subject aquifer.
Page 3 of 3
Date: April, 23, 2025
Subject: US Survey 3202, Lot 1
PO Box 671389 ● 18368 Amonson Road ● Chugiak, Alaska 99567
Please feel free to contact me if you have any questions.
James Jay Crewdson, P.E.
Appendix A
Existing wells near US Survey 3202 Lot 1
Notes:
1. Likely confining layers shown, but there may be other confining layers that
aren't as obvious.
2. The two closest wells with complete well logs are:
a. NE of the subject property: USS 3201 Lot 8: Well TD: 79, SWL: 12'
b. SE of the subject property: USS 3202 Lot 6: Well TD: 100', SWL: 22'
y,
Mun'dpafity of Anchorage
Ur�rn'tmont
P.O. Box 196650 0 4700 Elmore Road
Anchorage, Alaska 99519-6650 0 (907) 343-7904 0 Fax (907) 343-7997
http://www.muni.org/Onsite
Deyeloj?mentServices Division
On -Site Water and Wastewater Program
* * * * VARIANCE/WAIVER REVIEW * * * *
Waiver#: OSV251015 COSA#:
PID#: 090-022-23
Permit#: OSP251068
Legal Description: US SURVEY 3202 LT 1 T10N R1W SEC 10
Engineer: �� E- 1-,- 0 S �/,j
Your request for a waiver of the required 100 feet horizontal separation from the S.T.E.P. tank to
the private well has been approved. The approved separation distance is 62.0 feet.
This waiver approval applies to the proposed S.T.E.P. tank only. Any future upgrade to the on -
site wastewater disposal system will require all separation distances be met or another approval
from this department.
Waiver is Granted: X Waiver is not Granted:
T_
Date: 7 Z S7 Approved by:
Name of Reviewer
..............................................................................
**** VARIAN C EMAIVE R REVIEW ****
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP251068, Curtis Townsend, 04/24/25
Municipality of Anchorage
On -site Water and wastewater
REVIEWED FOR CODE COMPLIANCE
Performed For:
Legal Description
TH1
Municipality of Anchorage
Development Services Department
On -Site Water and Wastewater Section
4700 Elmore St.
P.O. Box 196650 Anchorage, AK 99519-6650
www.muni.org/onsite
(907)343-7904
Soils Log - Percolation Test
.51't2RS�1 8 CUVST,
a
J rnes A. Crewdson
Gf C11527r�'
Anne Marie Mayer Date Performed: 10-18-2024
US Survey 3202, Lot 1 Township, Range, Section:
Slope Site Plan
with Silt
MI.
bee
Design
Drawing
WAS GROUND WATER
ENCOUNTERED? NO
s
IF YES, AT WHAT DEPTH? L
Depth to Water After 0
P
Monitoring? Dry E
Date: 10-25-24
n
Drawing
See Design Drawing
Reading
Date
Gross Time
Net Time
Depth to Water
Net Drop
10-18-24
minutes
inches
10
3 9/16
10
3 8/16
10
3 8/16
10
3 7/16
10
13
7/16
10
1
3 7/16
PERCOLATION RATE L,y (minutesNnch) PERC HOLE DIAMETER 6"
TEST RUN BETWEEN _7 FT AND 8 FT
COMMENTS SM soils perc in the 6-15mpi range
PERFORMED BY: Crewdson Engineering LLC I James Crewdson CERTIFY THAT THIS TEST WAS
PERFORMED IN ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: 10-18-2024
04/24/2
Received Date/Time 03/07/2025 16:32
03/07/2025 15:30Collected Date/Time
1250853001
Matrix
SGS Ref.#
Client Sample ID Outside Spigot
Client Name
Project Name/#
Printed Date/Time 03/12/2025 12:07Residential Testing - Cash Account
Technical Director Stephen C. Ede
362 Konikson Rd, Bird Creek AK
Drinking Water
Sample Remarks:
Parameter Results LOQ Units Method
Allowable
Limits
Prep
Date
Analysis
Date InitContainer ID
Microbiology Laboratory
M.A03/07/25SM21 9223B100mLE. Coli Negative 1 A
M.A03/07/25SM21 9223B100mLTotal Coliform Negative 1 A
2 of 52 of 5
Revised Report-Revision 1
Received Date/Time 04/01/2025 10:14
04/01/2025 9:30Collected Date/Time
1251174001
Matrix
SGS Ref.#
Client Sample ID Outside Hosebib
Client Name
Project Name/#
Printed Date/Time 04/14/2025 16:02Crewdson Engineering LLC
Technical Director Stephen C. Ede
362 Konikson Rd.
Drinking Water
Sample Remarks:
Parameter Results LOQ Units Method
Allowable
Limits
Prep
Date
Analysis
Date InitContainer ID
Waters Department
MCP04/07/25SM21 4500NO3-Fmg/LTotal Nitrate/Nitrite-N 0.428 0.200 (<10) A
2 of 5
UNSUBDIVIDED
z
ILL
_
� N
U] m
W Cj
O
Q��
M
z
w
�ZI
m
O
w
J O
O
LO
0
O
,;I-
129
REBAR
W/CAP
CW WELL
DECK
24.0'
2-STORY W
FRAME
HOUSE
24.0'
N 49020'00" W 330.00'
50' RIGHT-OF-WAY EASEMENT
(PATENT No. 1192992)
-------rn--------------
1-STORY 11.2
FRAME
CABIN
I
BUILDING DETAIL 1" = 20'
LOT 1
SHED 2.50 ACRES
O
SEE
BUILDING
DETAIL
zo
m
S 49020'00" E 330.00'
LOT 6
THIS MORTGAGE LOCATION SURVEY
SHOULD ONLY BE USED FOR A SINGLE
PROPERTY TRANSACTION. RE -USE OF
THIS DRAWING BY THE ORIGINAL CLIENT
OR BY OTHERS, FOR ADDITIONAL USES
AT A LATER DATE WITHOUT EXPRESS
CONSENT OF THE SURVEYOR IS A
VIOLATION OF FEDERAL COPYRIGHT
LAW. UNLESS GROSS NEGLIGENCE IS
DISCOVERED, THE LIABILITY EXTENT OF
THE PREPARER SHALL BE LIMITED TO
THE AMOUNT OF FEES COLLECTED FOR
SERVICES IN PREPARATION OF THIS
PRODUCT.
EASEMENTS OF RECORD, OTHER THAN THOSE SHOWN ON THE
RECORDED SUBDIVISION PLATARE NOT SHOWN HEREON, UNLESS
OTHERWISE NOTED.
THIS DOCUMENT DOES NOT CONSTITUTE A BOUNDARY SURVEY AND
IS SUBJECT TO ANY INACCURACIES THATA SUBSEQUENT
BOUNDARY SURVEY MAY DISCLOSE.
UNDER NO CIRCUMSTANCES SHOULD ANY OF THE DATA HEREON BE
USED FOR CONSTRUCTION OF FENCES, IMPROVEMENTS, OR FOR
ESTABLISHING PROPERTY BOUNDARIES.
THIS SURVEY REPRESENTS A MORTGAGE LOCATION SURVEY
PREPARED IN ACCORDANCE WITH THE ASPLS MORTGAGE LOCATION
SURVEY STANDARDS.
0 25' 50'
O
O
0
H-
cM
z
w
CM
W rn
LIJ N
U) N
W m
- H
0
z
w
OZ
O
FL w
Ilt
0a
Z
wv
0
L
*: 49 TH * ;
......... ...................�
D�/09/23
�'. B u Sahz : �o
LS-14837
AS -BUILT
I HEREBY CERTIFY THAT I HAVE SURVEYED THE
FOLLOWING DESCRIBED PROPERTY:
LOT 1, U.S. SURVEY No. 3202
ANCHORAGE RECORDING DISTRICT, ALASKAAND THAT
THE VISIBLE IMPROVEMENTS SITUATED THEREON ARE
WITHIN THE PROPERTY LINES AND NO VISIBLE
ENCROACHMENTS EXIST EXCEPTAS INDICATED.
DATED THIS 7th DAY OF JULY, 2023, ATANCHORAGE,
ALASKA.
FIXED HEIGHT, LLC C.O.A.122554
Land Surveying Services 907.290.8949
225 W 23rd Ave., Anchorage, AK 99503 WWW.FIXEDHEIGHTCOM
JOB # 23092 I NO CORNERS SET THIS DATE I SCALE 1" = 50'