HomeMy WebLinkAboutT15N R1W SEC 8 LT 11515N RIW SEC 8
Lot 115
#051 - 151 - 16
MUNICIPALITY OF ANCHORAGE
On -Site Water & Wastewater Program
PO Box 196650 4700 Elmore Road
Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997
hftp://www.muni.org/onsite
On -Site Water & Wastewater System Permit
Permit Number: OSP251105
Work Type: WellSeptic Initial
Tax Code Number: 05115116000
Site Legal Address: T15N R1 W SEC 8 LT 115 G:1257
Site Mailing Address:
Owner: OAKES TIMOTHY O & DEBBIE R
Design Engineer: FORGE ENGINEERING
This permit is for the construction of:
Effective Date:
Expiration Date:
Lot Size in Sq Ft:
Total Bedrooms:
ellt
S,.
J.
I)eiiartIIIent
4/25/2025
4/25/2026
108900
Q Disposal Field Cif Septic Tank ❑ Holding Tank ❑ Privy Q Private Well ❑ Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
Special Provisions:
A test hole is required prior to construction of the absorption field, in the location shown on the site plan, to
confirm minimum separation to impermeable soil and seasonal high groundwater, as well as percolation rate.
Construction may proceed at your own risk prior to 7-day groundwater monitoring. If results require a design
change, construction shall stop pending approval of a change order. Please submit results with the inspection
report (or change order, if required).
% o 1, o�� �.
Received By: 1 - 1 Date:
Issued By: Date: Z, 2
3
ON -SITE SEPTIC/WELL PERMIT APPLICATION
Parcel I.D. 051-151-16
Property owner(s) Timothy Oakes
Mailing address PO BOX 672294, Chugiak, AK 99567
Site address NHN Jayhawk Dr / Crabtree St
Legal description
T15N R1W SEC 8 Lot 115
Number of Bedrooms 3
Engineering Firm Forge Engineering
Building Permit Number
Day phone
Not Applicable 0
APPLICATION IS FOR: APPLICATION IS AN:
(Z all that apply)
Absorption Field
M Initial El
Septic Tank
El Upgrade El
Holding Tank
1-1 Renewal EJ
Privy
D
Well
El
THIS APPLICATION INCLUDES A WAIVER REQUEST FOR:
Permit/Rush Fees:
Date of Payment:
0c. C
Permit No. _3 s- os-
Waiver Fees:
Date of Payment:
Waiver No.
Distance:
April 14, 2025
MOA Development Services, On-Site Water & Wastewater Program
4700 Elmore Rd
Anchorage, AK 99507
Subject: T15N R1W SEC 8 L115 – NHN Jayhawk Dr
Septic system design
Dear On-Site Services Engineer:
The owner of the above lot intends to build a 3-bedroom home on the property, so we are
submitting this permit application for the construction of a new well and septic system. The
attached site plan identifies the location of the home as well as the proposed well, septic location
and alternate site. No conflicts exist between this proposed system and any other well or septic
system, whether on this lot or adjacent lots.
The ground surface on the lot slopes toward the south side of the lot, and the septic trenches are
aligned along the contours in this area. There is a short section of steeper slopes (less than 25%)
near that corner, but the trenches are below that. There are no slopes greater than 25% within 50
feet downslope of either the primary or alternate site. Contours are shown on the site plan showing
the grade and direction of flow. Stormwater drainage will not impact this septic system. The new
trench will be constructed parallel to the slope as much as possible.
The test hole done previously was placed in an area that is now covered by the home site. We have
used that test hole for our design, while specifying that a new test hole must be done prior to
construction in the area that the septic will end up in.
Wells on this and adjacent lots are shown. The new system will be a minimum of 100’ from all
wells and surface water, and more than 5’ away from the septic tank. The alternate site is located
more than 6’ away. Please refer to the attached test hole log, plan and profile pages for the septic
design. If this design is followed, there will be no adverse impacts to adjacent properties.
Sincerely,
Benjamin Schiller, PE
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP251105, Curtis Townsend, 04/25/25
T15N R1W SEC 8 LOT 115
PERMIT # OSP251105
W
W
w
W
<
ct
ALTERNATE SITE
PID # 051-151-16
JAYHAWKI.,D'RIVE
�Er- — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — --
E N 6 IN E E R I m G1
s1 Mlvk LEGEND
OF AQ,
Aw
CO - CLEANOUT
2CO - DOUBLE CLEANOUT
. -49
TH SEPTIC PLAN
FCO - FOUNDATION CLEANOUT
• .
FS -FLOW SPLITTER VALVE
. .........
Benja C C i Schiller MH - MANHOLE
E 2592 0 50 100 7/3125 FEET MT - MONITORING TUBE
SV - SEPTIC VENT
1 =50TH - TEST HOLE
T15N R1 W SEC 8 LOT 115
DESIGN FACTORS: SYSTEM REQUIREMENTS:
450 GPD PEAK FLOW 5' WIDE TRENCH SYSTEM
PERK RATE: <1 MIN/IN 1000-GAL SEPTIC TANK
APPLICATION RATE: 1 GPD/SF
450 GPD / 1 GPD/SF / 5' WIDE * 1 RED FACTOR [0.5 DEEP] = 90 LF TRENCH REQUIRED (90 LF SPECIFIED)
BOTTOM OF TRENCH: 1' BELOW GRADE MAX
FLOW LINE ELEVATION: 0.5' BELOW GRADE
TYPICAL TRENCH SECTION
(NO SCALE)
NOTES:
1. GRADE AREA OVER TRENCH TO DRAIN AWAY
2. PROVIDE 3' OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2'
WITH 2" OF INSULATION
3. CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER
THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY
Cf) .6 1
Q.
E N G I NEE R I" G
• ' • • Benja Schiller
' �F �•. CE 12592 •`�i
7/3/25 , • •�V��
,`tli� PROFESSIONP�'.►
LEGAL DESCRIPTION:
PERFORMED FOR:
DATE: PARCEL ID#:
SOILS LOG AND PERCOLATION TEST
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
DEPTH
(feet)
TEST HOLE 1
DATE READING NET TIME
(minutes)
DEPTH to
WATER NET DROP
PERCOLATION RATE: (MIN/INCH)
(inches)(inches)
DATE OF MONITORING
DEPTH TO WATER AFTER MONITORING
<1
--- 1
2
3
4
5
6
GM (SILTY GRAVEL W/ SAND)
Professional Engineers Stamp:
T15N R1W SEC 8 LOT 115 - JAYHAWK LANE
3/21/25 051-151-16
ACES
159 8 16
1' OB
2
Benjamin Schiller
CE 12592REGISTEREDPROFESSION A L E N GINEER
PERC TEST LOCATION
TECHNICIAN: INSPECTOR
165 8 16
15.5'
3/28/25
COMMENTS:
SITE PLAN
6 0 16
USCS SOIL CLASSIFICATION WAS VISUALLY DETERMINED
4/10/25
MOISTURE NOTED AT TIME OF DIGGING?-
SP (SAND)
159 8 16 2.5 165 8 16 6 0 16
159 12 16 2.5 165 12 16 6 0 16
159 8 163 165 8 16 6 0 16
159 8 163 165 8 16 6 0 16
159 8 163 165 8 16 6 0 16
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP251105, Curtis Townsend, 04/25/25
E SOILS LOG AND PERCOLATION TEST
N G I N E E R 1 N G
DESCRIPTION:
ITTLE DIPPER
LEGAL NLC 8 LOT 115 - JAYHAWK LANE
PERFORMED FOR
DATE: 6 / 18 / 25 PARCEL ID#: 051-151-16
Professions
DEPTH TEST HOLE c-,� ,
(feet)
1
( � PERC TEST LOCATION
2 �•.
3
4 GM (SILTY GRAVEL W/ SAND)
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
YES MOISTURE NOTED AT TIME OF DIGGING?
NONE DEPTH TO WATER AFTER MONITORING
6/25/25 DATE OF MONITORING
DATE
READING
NET TIME
(MINUTES)
DEPTH TOWATERNET
(INCHES)
DROP
(INCHES)
6/18/25
1
0.1
159 %6
165 %6
6 %6
2
0.1
159 %6
165 %6
6 5116
3
0.1
15913416
165 5 716
6 %6
4
0.1
159 %6
165 %6
6 %6
5
0.1
159 6/6
165 %6
6 %6
6
0.1
159 %6
165 %6
6 %6
PERCOLATION RATE: <1 (MIN/INCH)
COMMENTS: USCS SOIL CLASSIFICATION WAS VISUALLY DETERMINED
SITE PLAN
TECHNICIAN: JUSTIN EARLS